TITLE DESIGN OF BASE PLATE DATE 12/03/2017

Project Gantry - Vaan Infra

TOTAL VERTIAL LOAD(P) 159.422 KN Dia of col 356


Max. bending moment M 267.142 KN-M
Eccentricity due to B.M. 1.675691 >L/3 Since eccentricity is high design will be d
Grade of concrete M25
Bearing strength concrete σcbc 8.5 N/mm^2
Increase in stress for wind load(σcbc) 11.05 N/mm^2
Modular ration (m) 10.98039
Grade of steel 250
σtf 120 N/mm^2
Increase in stress for wind load(σtf ) 150 N/mm^2
LENGTH OF BASE PLATE 600 mm
Edge distance of bolts ( r ) 50 mm
d 550 mm
n 245.946 mm
Lever arm 468.018 mm
Take moment about centre line of action of tensile force
C X LEVER ARM = M + PX(L/2- EDGE DISTANCE)
C 600 KN
Req. Width of base plate 441.5494 mm
Provided Width of base plate 650 mm
Projection of base plate 122 mm
Max. value of comressive stress 7.50634 N/mm^2
Stress ordinate at critical section 3.782865 N/mm^2
Bending moment at critical section 48792.07 N-mm
Thickness required 34.4936 mm
Tension force P1 440.578 KN
Req. net area of bolt 1409.85 mm^2

Dia of bolt 30 mm
area of one bolt 706.5
No. of bolt 2
Length of bolt req. 1391.979 mm

Provide 550x550x36 mm thk plate with 8 nos of 30 dia bolt 1400 mm long
ntricity is high design will be done as per concrete beam theory

172