Prepared By:
Hodge Design Associates, P.C.
22 Chestnut Street
Evansville, Indiana 47713-1022
812.422.2558 812.422.3337 (FAX)
www.hodgedesign.com
Project No. 04S-9999
12 July, 2004
Per your request, we have performed a structural analysis for the referenced antenna
tower. The purpose of the analysis was to investigate the structural adequacy of the tower for the
existing configuration (antennas, transmission lines and other appurtenances) under ice and wind
loading conditions with the addition of two, 8’diameter high performance dish antennas with
transmission lines at 200’ AGL.
Our structural analysis of the antenna tower is based on data provided by ABC Tower
and Tower Maintenance, Inc. and manufacturers' product data (please see Appendix A). We
assume that the data is correct. Structural analysis computations were performed utilizing
specialized computer software and the TIA-EIA-222-F Structural Standards for Steel Antenna
Towers and Antenna Supporting Structures. Please see Appendices B, C and D for structural
calculations.
Our structural analysis of the antenna tower indicates that the antenna tower is not in
conformance with the referenced design standard. Recommendations for tower modifications are
outlined below. The antenna tower structural analysis may be summarized as follows:
APPURTENANCE LIST
Elevation
(AGL) Appurtenances Transmission Lines
EXISTING
300’ FAA Beacon 2’ Rigid Conduit
300’ 6’ Lightning Rod
295’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
280’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
260’ (12) DB858 w/12’ T Frames (3 Sections) (12) 1 5/8
200’ Dual Obstruction Lights
100’ Dual Obstruction Lights
PROPOSED
200’ (2) UHX8-59 (2) EW 63
Please review the above appurtenance loading and contact us immediately if any discrepancies are
noted. This listing represents our understanding of the appurtenance loading required.
12 July, 2004
Mr. John Smith
ABC TOWER AND TOWER MAINTENANCE, INC.
123 Main Street
St, Louis, Missouri 99999
Re: Structural Analysis Report
300’ Self-Supporting Antenna Tower
Henderson, Henderson County, Kentucky
HDA Project No. 04S-9999
Page 4
This analysis report has been prepared without a site visit by Hodge Design Associates,
P.C. personnel. All sections, connections hardware, anchor material, etc. have been assumed to
be in good working order. Data provided by others is assumed to be correct. The opinions,
conclusions and recommendations contained in this report pertain only to the computer analysis
of the tower structure and the load carrying capacity of its members. It is the responsibility of
the tower owner, property manager or other responsible party to ensure that the tower is in good
working order and that the data provided by others is accurate and correct. The structural
analysis does not consider the fabrication quality, including welded and bolted connections,
except as specifically addressed in this report. If the structure has been altered or is different
from the tower depicted herein, Hodge Design Associates, P.C. should be informed immediately.
Hodge Design Associates, P.C. makes no warranties, expressed or implied in connection with
this report and disclaims any liability arising from the original design, material, fabrication and
erection deficiencies for this tower. The maximum liability of Hodge Design Associates, P.C.
pursuant to this report shall be limited to the total fee received for the preparation of this report.
12 July, 2004
Mr. John Smith
ABC TOWER AND TOWER MAINTENANCE, INC.
123 Main Street
St, Louis, Missouri 99999
Re: Structural Analysis Report
300’ Self-Supporting Antenna Tower
Henderson, Henderson County, Kentucky
HDA Project No. 04S-9999
Page 6
If you have any questions regarding this matter, please do not hesitate to contact me.
Sincerely,
4
SR 1 1/2
SR 3/4
SR 3/4
SR 3/4
SeeDB858DDH65E-SX
Lightning
(4)
12'
Lighting
T-Frame
E-7 -for
Rod
Dual
Beacon
Feedlines
Sector
6'Obstruction
Mount
and Linear 300
295
280
260
200
100
0
APPURTENANCES
0.7
T1
Appurtenances
12 @ 3.20833
TYPE ELEVATION TYPE ELEVATION
280.0 ft Lighting - Beacon 300 (4) DB858DDH65E-SX 280
Lightning Rod 6' 300 12' T-Frame Sector Mount 280
SR 7/8
SR 7/8
SR 7/8
(4) DB858DDH65E-SX 295 (4) DB858DDH65E-SX 260
SR 2
1.1
T2
12' T-Frame Sector Mount 295 12' T-Frame Sector Mount 260
(4) DB858DDH65E-SX 295 (4) DB858DDH65E-SX 260
260.0 ft 12' T-Frame Sector Mount 295 12' T-Frame Sector Mount 260
(4) DB858DDH65E-SX 295 (4) DB858DDH65E-SX 260
12' T-Frame Sector Mount 295 12' T-Frame Sector Mount 260
SR 3
2.0
T3
SYMBOL LIST
L2x2x3/16
SR 3 1/4
MATERIAL STRENGTH
2.4
T5
GRADE Fy Fu GRADE Fy Fu
200.0 ft A572-50 50 ksi 65 ksi A36 36 ksi 58 ksi
9.07813
3. Tower is also designed for a 61 mph basic wind with 0.50 in ice.
L2x2x1/4
SR 3 1/2
6. It is assumed that the tower has been properly maintained and is in good condition.
160.0 ft 7. It is assumed that there have been no structural modifications to the tower unless
12.4609
A36
9. All welds and bolted connections are assumed capable of developing the member
3.0
T8
L2 1/2x2 1/2x3/16
11. This structural analysis is based on information provided by others and assumed to be
39 @ 6.16667
N.A.
3.8
A
100.0 ft
17.5391
L3x3x3/16
T11
3.8
80.0 ft
MAX PIER FORCES:
19.2318
DOWN: 344 K
L3x3x1/4
UPLIFT: -287 K
T12
4.7
SHEAR: 26 K
SR 4
60.0 ft
20.9219
AXIAL
96 K
T13
4.6
B
MOMENT
SHEAR
40.0 ft
6901 kip-ft
40 K
22.6146
TORQUE 3 kip-ft
T14
5.7
C
20.0 ft
66 K
24.3073
MOMENT
L4x4x1/4
7244 kip-ft
SHEAR
T15
6.3
42 K
0.0 ft
26
49.6
TORQUE 2 kip-ft
REACTIONS - 70 mph WIND
Diagonal Grade
# Panels @ (ft)
Face Width (ft)
Bottom Girts
Weight (K)
Leg Grade
Diagonals
Top Girts
Section
Legs
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-1
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Leg Capacity Leg Compression (K)
1000 500 <- Minimum 0 Maximum -> -500 -1000
300' 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-3
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice Maximum Values
Vx Vz Mx Mz
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
0 50 0 5000 10000
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-4
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
TIA/EIA-222-F - Service - 50 mph Maximum Values
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-5
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
Feedline Distribution Chart
0' - 300'
Round Flat App In Face App Out Face Truss Leg
300'
Face A Face B Face C 300'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
(12) 1 5/8
140' 140'
(12) 1 5/8
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
10' 10'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
Feedline Plan
(12)Ladder
Feedline 1 5/8
B
A
(12) 1 5/8
Feedline Ladder
C
1 der
uit
5/8
nd
2) d
(1e La
Co
lin
gid
ed
Ri
Fe
2"
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
Stress Distribution Chart
0' - 300'
> 100% 90%-100% 75%-90% 50%-75% < 50% Overstress
300'
Face A Face B Face C 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower Condition Analysis
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-8
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R1.eri
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 1 of 20
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:49:20 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
The main tower is a 3x free standing tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 4' at the top and 26' at the base.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Tower is located in Henderson County, Kentucky.
Basic wind speed of 70 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 61 mph is used in combination with ice.
Temperature drop of 75 °F.
Deflections calculated using a wind speed of 50 mph.
EXISTING TOWER CONDITION ANALYSIS.
It is assumed that the tower has been properly maintained and is in good condition..
It is assumed that there have been no structural modifications to the tower unless specifically noted otherwise..
There are no known structural defects and that there is no structural deterioration..
All welds and bolted connections are assumed capable of developing the member strength, unless noted otherwise..
Material strengths are as noted elsewhere in this report..
This structural analysis is based on information provided by others and assumed to be reliable and correct..
See Sheet E-7 for Feedlines and Linear Appurtenances..
See Sheet E-8 for Code Check/Stress Distribution..
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.333.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform v Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals v Assume Rigid Index Plate v Calculate Redundant Bracing Forces
Use Moment Magnification v Use Clear Spans For Wind Area v Ignore Redundant Members in FEA
v Use Code Stress Ratios v Use Clear Spans For KL/r v SR Leg Bolts Resist Compression
v Use Code Safety Factors - Guys v Retension Guys To Initial Tension v All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz v Use Azimuth Dish Coefficients v Consider Feedline Torque
Use Special Wind Profile v Project Wind Area of Appurt. v Include Angle Block Shear Check
Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
v Leg Bolts Are At Top Of Section v SR Members Have Cut Ends v Include Shear-Torsion Interaction
v Secondary Horizontal Braces Leg v Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) v Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 2 of 20
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:49:20 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Wind 180
Leg A
Wind 90
Fa
A
ce
ce
B
Fa X
Leg C Z Leg B
Face C
Wind Normal
Triangular Tower
Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt
Section Elevation Spacing Type K Brace Horizontals Offset Offset
End
ft ft Panels in in
T1 300'-280' 3'2-17/32'' X Brace No No 4.5000 4.5000
T2 280'-260' 3'2-17/32'' X Brace No No 4.5000 4.5000
T3 260'-240' 6'2-1/32'' X Brace No No 9.0000 9.0000
T4 240'-220' 6'2-1/32'' X Brace No No 9.0000 9.0000
T5 220'-200' 6'2-1/32'' X Brace No No 9.0000 9.0000
T6 200'-180' 6'2-1/32'' X Brace No No 9.0000 9.0000
T7 180'-160' 6'2-1/32'' X Brace No No 9.0000 9.0000
T8 160'-140' 6'2-1/32'' X Brace No No 9.0000 9.0000
T9 140'-120' 6'2-1/32'' X Brace No No 9.0000 9.0000
T10 120'-100' 6'2-1/32'' X Brace No No 9.0000 9.0000
T11 100'-80' 6'2-1/32'' X Brace No No 9.0000 9.0000
T12 80'-60' 6'2-1/32'' X Brace No No 9.0000 9.0000
T13 60'-40' 6'2-1/32'' X Brace No No 9.0000 9.0000
T14 40'-20' 6'2-1/32'' X Brace No No 9.0000 9.0000
T15 20'-0' 6'2-1/32'' X Brace No No 9.0000 9.0000
Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Elevation
ft
Net Width U Net Width U Net Width U Net U Net U Net U Net U
Deduct Deduct Deduct Width Width Width Width
in in in Deduct Deduct Deduct Deduct
in in in in
T14 40'-20' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T15 20'-0' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Load Combinations
Comb. Description
No.
1 Dead Only
2 Dead+Wind 0 deg - No Ice
3 Dead+Wind 30 deg - No Ice
4 Dead+Wind 60 deg - No Ice
5 Dead+Wind 90 deg - No Ice
6 Dead+Wind 120 deg - No Ice
7 Dead+Wind 150 deg - No Ice
8 Dead+Wind 180 deg - No Ice
9 Dead+Wind 210 deg - No Ice
10 Dead+Wind 240 deg - No Ice
11 Dead+Wind 270 deg - No Ice
12 Dead+Wind 300 deg - No Ice
13 Dead+Wind 330 deg - No Ice
14 Dead+Ice+Temp
15 Dead+Wind 0 deg+Ice+Temp
16 Dead+Wind 30 deg+Ice+Temp
17 Dead+Wind 60 deg+Ice+Temp
18 Dead+Wind 90 deg+Ice+Temp
19 Dead+Wind 120 deg+Ice+Temp
20 Dead+Wind 150 deg+Ice+Temp
21 Dead+Wind 180 deg+Ice+Temp
22 Dead+Wind 210 deg+Ice+Temp
23 Dead+Wind 240 deg+Ice+Temp
24 Dead+Wind 270 deg+Ice+Temp
25 Dead+Wind 300 deg+Ice+Temp
26 Dead+Wind 330 deg+Ice+Temp
27 Dead+Wind 0 deg - Service
28 Dead+Wind 30 deg - Service
29 Dead+Wind 60 deg - Service
30 Dead+Wind 90 deg - Service
31 Dead+Wind 120 deg - Service
32 Dead+Wind 150 deg - Service
33 Dead+Wind 180 deg - Service
34 Dead+Wind 210 deg - Service
35 Dead+Wind 240 deg - Service
36 Dead+Wind 270 deg - Service
37 Dead+Wind 300 deg - Service
38 Dead+Wind 330 deg - Service
Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load K K K
Comb.
Leg C Max. Vert 10 343.67 22.25 -12.80
Max. Hx 10 343.67 22.25 -12.80
Max. Hz 16 -216.66 -17.38 11.60
Min. Vert 4 -286.94 -19.49 11.21
Min. Hx 17 -248.71 -20.16 11.58
Min. Hz 10 343.67 22.25 -12.80
Leg B Max. Vert 6 343.87 -22.23 -12.83
Max. Hx 25 -248.39 20.13 11.61
Max. Hz 26 -216.34 17.34 11.66
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 12 of 20
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:49:20 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. K K K K K K
1 0.00 -66.38 0.00 0.00 66.38 0.00 0.000%
2 0.00 -66.38 -42.23 0.00 66.38 42.23 0.005%
3 20.04 -66.38 -34.72 -20.04 66.38 34.71 0.005%
4 34.10 -66.38 -19.69 -34.09 66.38 19.68 0.005%
5 40.09 -66.38 0.00 -40.08 66.38 0.00 0.005%
6 36.57 -66.38 21.12 -36.57 66.38 -21.11 0.005%
7 20.04 -66.38 34.72 -20.04 66.38 -34.71 0.005%
8 0.00 -66.38 39.37 0.00 66.38 -39.37 0.005%
9 -20.04 -66.38 34.72 20.04 66.38 -34.71 0.005%
10 -36.57 -66.38 21.12 36.57 66.38 -21.11 0.005%
11 -40.09 -66.38 0.00 40.08 66.38 0.00 0.005%
12 -34.10 -66.38 -19.69 34.09 66.38 19.68 0.005%
13 -20.04 -66.38 -34.72 20.04 66.38 34.71 0.005%
14 0.00 -96.00 0.00 0.00 96.00 0.00 0.000%
15 0.00 -96.00 -40.22 0.00 96.00 40.22 0.003%
16 18.43 -96.00 -31.92 -18.43 96.00 31.91 0.003%
17 30.95 -96.00 -17.87 -30.94 96.00 17.86 0.003%
18 36.86 -96.00 0.00 -36.85 96.00 0.00 0.003%
19 34.83 -96.00 20.11 -34.83 96.00 -20.11 0.003%
20 18.43 -96.00 31.92 -18.43 96.00 -31.91 0.003%
21 0.00 -96.00 35.73 0.00 96.00 -35.73 0.003%
22 -18.43 -96.00 31.92 18.43 96.00 -31.91 0.003%
23 -34.83 -96.00 20.11 34.83 96.00 -20.11 0.003%
24 -36.86 -96.00 0.00 36.85 96.00 0.00 0.003%
25 -30.95 -96.00 -17.87 30.94 96.00 17.86 0.003%
26 -18.43 -96.00 -31.92 18.43 96.00 31.91 0.003%
27 0.00 -66.38 -21.55 0.00 66.38 21.54 0.003%
28 10.23 -66.38 -17.71 -10.23 66.38 17.71 0.003%
29 17.40 -66.38 -10.04 -17.39 66.38 10.04 0.003%
30 20.45 -66.38 0.00 -20.45 66.38 0.00 0.003%
31 18.66 -66.38 10.77 -18.66 66.38 -10.77 0.003%
32 10.23 -66.38 17.71 -10.23 66.38 -17.71 0.003%
33 0.00 -66.38 20.09 0.00 66.38 -20.09 0.003%
34 -10.23 -66.38 17.71 10.23 66.38 -17.71 0.003%
35 -18.66 -66.38 10.77 18.66 66.38 -10.77 0.003%
36 -20.45 -66.38 0.00 20.45 66.38 0.00 0.003%
37 -17.40 -66.38 -10.04 17.39 66.38 10.04 0.003%
38 -10.23 -66.38 -17.71 10.23 66.38 17.71 0.003%
Compression Checks
Tension Checks
T4 240 - 220 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 130.62 248.87 0.525
T5 220 - 200 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 149.18 248.87 0.599
T6 200 - 180 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 165.58 288.63 0.574
T7 180 - 160 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 180.51 288.63 0.625
T8 160 - 140 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 194.69 288.63 0.675
T9 140 - 120 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 208.58 331.34 0.630
T10 120 - 100 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 222.13 331.34 0.670
T11 100 - 80 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 235.58 331.34 0.711
T14 40 - 20 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 275.08 425.59 0.646
T15 20 - 0 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 287.83 425.59 0.676
T2 280 - 260 7/8 5'1-9/16'' 2'5- 134.8 21.600 0.6013 4.81 12.99 0.370
17/32''
T3 260 - 240 L2x2x3/16 7'6-3/8'' 3'9- 74.0 21.600 0.7150 5.36 15.44 0.347
19/32''
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 19 of 20
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower 12:49:20 07/23/04
Condition Analysis
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Program Version 3.0.0.16 - 7/10/2004 File:C:/Documents and Settings/ghodge.HODGEDESIGN.000/My Documents/ERITower Project Data Files/Sample
Reports/Sample-SS-R1.eri
APPENDIX C
Antenna Tower With Proposed Additional Antennas
4
SR 1 1/2
SR 3/4
SR 3/4
SR 3/4
SeeDB858DDH65E-SX
Lightning
(4)
12'
UHX8-59
Lighting
T-Frame
E-7 -for
Rod
Dual
Beacon
(Proposed)
Feedlines
Sector
6'Obstruction
Mount
and Linear 300
295
280
260
200
100
0
APPURTENANCES
0.7
T1
Appurtenances
12 @ 3.20833
TYPE ELEVATION TYPE ELEVATION
280.0 ft Lighting - Beacon 300 12' T-Frame Sector Mount 280
Lightning Rod 6' 300 (4) DB858DDH65E-SX 260
SR 7/8
SR 7/8
SR 7/8
(4) DB858DDH65E-SX 295 12' T-Frame Sector Mount 260
SR 2
1.1
T2
2.0
T3
12' T-Frame Sector Mount 280 See E-7 for Feedlines and Linear 0
(4) DB858DDH65E-SX 280 Appurtenances
2.3
T4
L2x2x3/16
SYMBOL LIST
SR 3 1/4
220.0 ft
MARK SIZE MARK SIZE
7.38542
MATERIAL STRENGTH
200.0 ft GRADE Fy Fu GRADE Fy Fu
9.07813
2. Tower designed for a 70 mph basic wind in accordance with the TIA/EIA-222-F Standard.
L2x2x1/4
SR 3 1/2
3. Tower is also designed for a 61 mph basic wind with 0.50 in ice.
3.0
T7
7. It is assumed that there have been no structural modifications to the tower unless
specifically noted otherwise.
A572-50
A36
3.0
8. There are no known structural defects and that there is no structural deterioration.
T8
L2 1/2x2 1/2x3/16
9. All welds and bolted connections are assumed capable of developing the member
140.0 ft strength, unless noted otherwise.
14.1536
11. This structural analysis is based on information provided by others and assumed to be
N.A.
N.A.
3.8
A
100.0 ft
17.5391
L3x3x3/16
T11
3.8
80.0 ft
MAX PIER FORCES:
19.2318
DOWN: 374 K
L3x3x1/4
UPLIFT: -315 K
T12
4.7
SHEAR: 28 K
SR 4
60.0 ft
20.9219
AXIAL
98 K
T13
4.6
B
MOMENT
SHEAR
40.0 ft
7441 kip-ft
44 K
22.6146
TORQUE 3 kip-ft
T14
5.7
C
20.0 ft
67 K
24.3073
MOMENT
L4x4x1/4
7919 kip-ft
SHEAR
T15
6.3
46 K
0.0 ft
26
49.6
TORQUE 2 kip-ft
REACTIONS - 70 mph WIND
Diagonal Grade
# Panels @ (ft)
Face Width (ft)
Bottom Girts
Weight (K)
Leg Grade
Diagonals
Top Girts
Section
Legs
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-1
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Leg Capacity Leg Compression (K)
1000 500 <- Minimum 0 Maximum -> -500 -1000
300' 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-3
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice Maximum Values
Vx Vz Mx Mz
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
0 50 0 5000 10000
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-4
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
TIA/EIA-222-F - Service - 50 mph Maximum Values
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-5
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
Feedline Distribution Chart
0' - 300'
Round Flat App In Face App Out Face Truss Leg
300'
Face A Face B Face C 300'
240' 240'
220' 220'
180' 180'
Elevation (ft)
(12) 1 5/8
140' 140'
(12) 1 5/8
(2) EW63 (to Proposed Antennas)
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
10' 10'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
Feedline Plan
(12)Ladder
Feedline 1 5/8
B
A
C
1 der
uit
5/8
nd
2) d
(1e La
Co
lin
gid
ed
Ri
Fe
2"
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
Stress Distribution Chart
0' - 300'
> 100% 90%-100% 75%-90% 50%-75% < 50% Overstress
300'
Face A Face B Face C 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Additional Antennas
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-8
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R2.eri
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 1 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
The main tower is a 3x free standing tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 4' at the top and 26' at the base.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Tower is located in Henderson County, Kentucky.
Basic wind speed of 70 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 61 mph is used in combination with ice.
Temperature drop of 75 °F.
Deflections calculated using a wind speed of 50 mph.
EXISTING TOWER WITH PROPOSED ADDITIONAL ANTENNAS.
It is assumed that the tower has been properly maintained and is in good condition..
It is assumed that there have been no structural modifications to the tower unless specifically noted otherwise..
There are no known structural defects and that there is no structural deterioration..
All welds and bolted connections are assumed capable of developing the member strength, unless noted otherwise..
Material strengths are as noted elsewhere in this report..
This structural analysis is based on information provided by others and assumed to be reliable and correct..
See Sheet E-7 for Feedlines and Linear Appurtenances..
See Sheet E-8 for Code Check/Stress Distribution..
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.333.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform v Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals v Assume Rigid Index Plate v Calculate Redundant Bracing Forces
Use Moment Magnification v Use Clear Spans For Wind Area v Ignore Redundant Members in FEA
v Use Code Stress Ratios v Use Clear Spans For KL/r v SR Leg Bolts Resist Compression
v Use Code Safety Factors - Guys v Retension Guys To Initial Tension v All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz v Use Azimuth Dish Coefficients v Consider Feedline Torque
Use Special Wind Profile v Project Wind Area of Appurt. v Include Angle Block Shear Check
Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
v Leg Bolts Are At Top Of Section v SR Members Have Cut Ends v Include Shear-Torsion Interaction
v Secondary Horizontal Braces Leg v Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) v Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 2 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Wind 180
Leg A
Wind 90
Fa
A
ce
ce
B
Fa X
Leg C Z Leg B
Face C
Wind Normal
Triangular Tower
Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt
Section Elevation Spacing Type K Brace Horizontals Offset Offset
End
ft ft Panels in in
T1 300'-280' 3'2-17/32'' X Brace No No 4.5000 4.5000
T2 280'-260' 3'2-17/32'' X Brace No No 4.5000 4.5000
T3 260'-240' 6'2-1/32'' X Brace No No 9.0000 9.0000
T4 240'-220' 6'2-1/32'' X Brace No No 9.0000 9.0000
T5 220'-200' 6'2-1/32'' X Brace No No 9.0000 9.0000
T6 200'-180' 6'2-1/32'' X Brace No No 9.0000 9.0000
T7 180'-160' 6'2-1/32'' X Brace No No 9.0000 9.0000
T8 160'-140' 6'2-1/32'' X Brace No No 9.0000 9.0000
T9 140'-120' 6'2-1/32'' X Brace No No 9.0000 9.0000
T10 120'-100' 6'2-1/32'' X Brace No No 9.0000 9.0000
T11 100'-80' 6'2-1/32'' X Brace No No 9.0000 9.0000
T12 80'-60' 6'2-1/32'' X Brace No No 9.0000 9.0000
T13 60'-40' 6'2-1/32'' X Brace No No 9.0000 9.0000
T14 40'-20' 6'2-1/32'' X Brace No No 9.0000 9.0000
T15 20'-0' 6'2-1/32'' X Brace No No 9.0000 9.0000
Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Elevation
ft
Net Width U Net Width U Net Width U Net U Net U Net U Net U
Deduct Deduct Deduct Width Width Width Width
in in in Deduct Deduct Deduct Deduct
in in in in
T14 40'-20' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T15 20'-0' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ° ° ft ft ft2 K
UHX8-59 A Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Leg 0' 1/2'' Ice 51.29 0.51
0'
UHX8-59 C Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Face 0' 1/2'' Ice 51.29 0.51
0'
Load Combinations
Comb. Description
No.
1 Dead Only
2 Dead+Wind 0 deg - No Ice
3 Dead+Wind 30 deg - No Ice
4 Dead+Wind 60 deg - No Ice
5 Dead+Wind 90 deg - No Ice
6 Dead+Wind 120 deg - No Ice
7 Dead+Wind 150 deg - No Ice
8 Dead+Wind 180 deg - No Ice
9 Dead+Wind 210 deg - No Ice
10 Dead+Wind 240 deg - No Ice
11 Dead+Wind 270 deg - No Ice
12 Dead+Wind 300 deg - No Ice
13 Dead+Wind 330 deg - No Ice
14 Dead+Ice+Temp
15 Dead+Wind 0 deg+Ice+Temp
16 Dead+Wind 30 deg+Ice+Temp
17 Dead+Wind 60 deg+Ice+Temp
18 Dead+Wind 90 deg+Ice+Temp
19 Dead+Wind 120 deg+Ice+Temp
20 Dead+Wind 150 deg+Ice+Temp
21 Dead+Wind 180 deg+Ice+Temp
22 Dead+Wind 210 deg+Ice+Temp
23 Dead+Wind 240 deg+Ice+Temp
24 Dead+Wind 270 deg+Ice+Temp
25 Dead+Wind 300 deg+Ice+Temp
26 Dead+Wind 330 deg+Ice+Temp
27 Dead+Wind 0 deg - Service
28 Dead+Wind 30 deg - Service
29 Dead+Wind 60 deg - Service
30 Dead+Wind 90 deg - Service
31 Dead+Wind 120 deg - Service
32 Dead+Wind 150 deg - Service
33 Dead+Wind 180 deg - Service
34 Dead+Wind 210 deg - Service
35 Dead+Wind 240 deg - Service
36 Dead+Wind 270 deg - Service
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 12 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Comb. Description
No.
37 Dead+Wind 300 deg - Service
38 Dead+Wind 330 deg - Service
Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load K K K
Comb.
Leg C Max. Vert 10 366.41 23.71 -13.75
Max. Hx 10 366.41 23.71 -13.75
Max. Hz 16 -231.34 -18.35 12.42
Min. Vert 4 -306.82 -20.82 12.16
Min. Hx 17 -264.12 -21.23 12.33
Min. Hz 10 366.41 23.71 -13.75
Leg B Max. Vert 6 366.51 -23.73 -13.71
Max. Hx 25 -264.17 21.26 12.29
Max. Hz 26 -231.38 18.39 12.35
Min. Vert 12 -306.72 20.84 12.12
Min. Hx 6 366.51 -23.73 -13.71
Min. Hz 6 366.51 -23.73 -13.71
Leg A Max. Vert 2 374.04 -0.04 27.90
Max. Hx 10 -158.94 3.31 -12.81
Max. Hz 2 374.04 -0.04 27.90
Min. Vert 8 -314.64 0.05 -24.66
Min. Hx 6 -158.94 -3.25 -12.81
Min. Hz 21 -270.27 0.05 -24.98
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. K K K K K K
1 0.00 -67.07 0.00 -0.00 67.07 0.00 0.000%
2 0.00 -67.07 -46.21 -0.00 67.07 46.20 0.005%
3 21.02 -67.07 -38.08 -21.02 67.07 38.08 0.005%
4 35.80 -67.07 -22.04 -35.80 67.07 22.03 0.005%
5 42.54 -67.07 0.00 -42.53 67.07 0.00 0.005%
6 38.68 -67.07 23.70 -38.67 67.07 -23.70 0.005%
7 21.02 -67.07 38.08 -21.02 67.07 -38.08 0.005%
8 0.00 -67.07 42.88 0.00 67.07 -42.88 0.005%
9 -21.02 -67.07 38.08 21.02 67.07 -38.08 0.005%
10 -38.68 -67.07 23.70 38.67 67.07 -23.70 0.005%
11 -42.54 -67.07 0.00 42.53 67.07 0.00 0.005%
12 -35.80 -67.07 -22.04 35.80 67.07 22.03 0.005%
13 -21.02 -67.07 -38.08 21.02 67.07 38.08 0.005%
14 0.00 -97.73 0.00 0.00 97.73 0.00 0.000%
15 0.00 -97.73 -43.51 -0.00 97.73 43.50 0.003%
16 19.26 -97.73 -34.64 -19.26 97.73 34.63 0.003%
17 32.37 -97.73 -19.73 -32.36 97.73 19.73 0.003%
18 38.89 -97.73 0.00 -38.89 97.73 0.00 0.003%
19 36.65 -97.73 22.21 -36.65 97.73 -22.21 0.003%
20 19.26 -97.73 34.64 -19.26 97.73 -34.63 0.003%
21 0.00 -97.73 38.56 0.00 97.73 -38.56 0.003%
22 -19.26 -97.73 34.64 19.26 97.73 -34.63 0.003%
23 -36.65 -97.73 22.21 36.65 97.73 -22.21 0.003%
24 -38.89 -97.73 0.00 38.89 97.73 0.00 0.003%
25 -32.37 -97.73 -19.73 32.36 97.73 19.73 0.003%
26 -19.26 -97.73 -34.64 19.26 97.73 34.63 0.003%
27 0.00 -67.07 -23.58 0.00 67.07 23.57 0.003%
28 10.73 -67.07 -19.43 -10.72 67.07 19.43 0.003%
29 18.26 -67.07 -11.24 -18.26 67.07 11.24 0.003%
30 21.70 -67.07 0.00 -21.70 67.07 0.00 0.003%
31 19.73 -67.07 12.09 -19.73 67.07 -12.09 0.003%
32 10.73 -67.07 19.43 -10.72 67.07 -19.43 0.003%
33 0.00 -67.07 21.88 0.00 67.07 -21.88 0.003%
34 -10.73 -67.07 19.43 10.72 67.07 -19.43 0.003%
35 -19.73 -67.07 12.09 19.73 67.07 -12.09 0.003%
36 -21.70 -67.07 0.00 21.70 67.07 0.00 0.003%
37 -18.26 -67.07 -11.24 18.26 67.07 11.24 0.003%
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 14 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Compression Checks
Tension Checks
T4 240 - 220 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 130.68 248.87 0.525
T5 220 - 200 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 149.33 248.87 0.600
T6 200 - 180 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 171.24 288.63 0.593
T7 180 - 160 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 190.59 288.63 0.660
T8 160 - 140 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 208.29 288.63 0.722
T9 140 - 120 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 225.11 331.34 0.679
T10 120 - 100 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 241.14 331.34 0.728
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 19 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
T14 40 - 20 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 301.40 425.59 0.708
T15 20 - 0 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 315.54 425.59 0.741
T2 280 - 260 7/8 5'1-9/16'' 2'5- 134.8 21.600 0.6013 4.81 12.99 0.370
17/32''
T3 260 - 240 L2x2x3/16 7'6-3/8'' 3'9- 74.0 21.600 0.7150 5.37 15.44 0.347
19/32''
T4 240 - 220 L2x2x3/16 8'7-7/16'' 4'3- 83.9 21.600 0.7150 3.80 15.44 0.246
27/32''
T5 220 - 200 L2x2x3/16 10'8- 5'4-3/16'' 104.0 21.600 0.7150 3.62 15.44 0.235
17/32''
T6 200 - 180 L2x2x3/16 12'1- 6'19/32'' 117.6 21.600 0.7150 4.70 15.44 0.305
9/16''
H1-3 (1.40 CR) - 160
T7 180 - 160 L2x2x1/4 13'7- 6'9- 133.8 21.600 0.9380 4.77 20.26 0.235
5/16'' 15/32''
T8 160 - 140 L2 1/2x2 1/2x3/16 15'1- 7'6- 116.5 21.600 0.9020 4.92 19.48 0.252
11/16'' 19/32''
T9 140 - 120 L2 1/2x2 1/2x3/16 16'8- 8'3- 128.4 21.600 0.9020 5.28 19.48 0.271
13/32'' 27/32''
T10 120 - 100 L2 1/2x2 1/2x1/4 18'3- 9'1-7/16'' 142.3 21.600 1.1900 5.69 25.70 0.221
15/32''
T11 100 - 80 L3x3x3/16 19'10- 9'11- 126.7 21.600 1.0900 5.99 23.54 0.254
11/16'' 1/32''
H1-3 (1.38 CR) - 266
T12 80 - 60 L3x3x1/4 21'6'' 10'8- 138.2 21.600 1.4400 6.58 31.10 0.212
17/32''
T13 60 - 40 L3 1/2x3 1/2x3/16 23'1- 11'6-3/8'' 125.7 21.600 1.2773 6.84 27.59 0.248
9/16''
H1-3 (1.33 CR) - 308
T14 40 - 20 L3 1/2x3 1/2x1/4 24'9-1/8'' 12'3- 135.8 21.600 1.6900 7.38 36.50 0.202
31/32''
T15 20 - 0 L4x4x1/4 26'4- 13'1- 126.3 21.600 1.9400 9.11 41.90 0.217
29/32'' 29/32''
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 20 of 21
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 12:55:40 07/23/04
Proposed Additional Antennas
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Program Version 3.0.0.16 - 7/10/2004 File:C:/Documents and Settings/ghodge.HODGEDESIGN.000/My Documents/ERITower Project Data Files/Sample
Reports/Sample-SS-R2.eri
APPENDIX D
Antenna Tower With Proposed Additional Antennas and Modifications
4
SR 1 1/2
SR 3/4
SR 3/4
SR 3/4
SeeDB858DDH65E-SX
Lightning
(4)
12'
UHX8-59
Lighting
T-Frame
E-7 -for
Rod
Dual
Beacon
(Proposed)
Feedlines
Sector
6'Obstruction
Mount
and Linear 300
295
280
260
200
100
0
APPURTENANCES
0.7
T1
Appurtenances
12 @ 3.20833
TYPE ELEVATION TYPE ELEVATION
280.0 ft Lighting - Beacon 300 12' T-Frame Sector Mount 280
Lightning Rod 6' 300 (4) DB858DDH65E-SX 260
SR 7/8
SR 7/8
SR 7/8
(4) DB858DDH65E-SX 295 12' T-Frame Sector Mount 260
SR 2
1.1
T2
2.0
T3
12' T-Frame Sector Mount 280 See E-7 for Feedlines and Linear 0
L2x2x3/16
2.3
T4
SYMBOL LIST
SR 3 1/4
220.0 ft
MARK SIZE MARK SIZE
7.38542
MATERIAL STRENGTH
200.0 ft GRADE Fy Fu GRADE Fy Fu
9.07813
2L2x2x1/4x3/4 2L2x2x3/16x3/4
2. Tower designed for a 70 mph basic wind in accordance with the TIA/EIA-222-F Standard.
SR 3 1/2
3. Tower is also designed for a 61 mph basic wind with 0.50 in ice.
3.7
T7
7. It is assumed that there have been no structural modifications to the tower unless
specifically noted otherwise.
A572-50
A36
3.6
8. There are no known structural defects and that there is no structural deterioration.
T8
9. All welds and bolted connections are assumed capable of developing the member
140.0 ft strength, unless noted otherwise.
14.1536
11. This structural analysis is based on information provided by others and assumed to be
N.A.
N.A.
120.0 ft
14. TOWER RATING: 97.2%
15.8464
SR 3 3/4
T10
5.1
C
100.0 ft
17.5391
2L3x3x1/4x3/8 2L3x3x3/16x3/4
2L2x2x3/16x3/4
T11
5.9
80.0 ft
MAX PIER FORCES:
19.2318
DOWN: 383 K
N.A.
UPLIFT: -313 K
T12
6.6
SHEAR: 29 K
SR 4
60.0 ft
20.9219
AXIAL
2L2x2x3/16x3/4
119 K
2L3 1/2x3 1/2x1/4x3/4
T13
8.5
MOMENT
SHEAR
40.0 ft
7519 kip-ft
44 K
22.6146
TORQUE 3 kip-ft
T14
8.2
N.A.
20.0 ft
82 K
24.3073
MOMENT
L4x4x1/4
8007 kip-ft
SHEAR
T15
6.3
47 K
0.0 ft
26
64.1
TORQUE 2 kip-ft
Sec. Horizontals
# Panels @ (ft)
Face Width (ft)
Bottom Girts
Weight (K)
Leg Grade
Diagonals
Top Girts
Section
Legs
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-1
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice
Leg Capacity Leg Compression (K)
1000 500 <- Minimum 0 Maximum -> -500 -1000
300' 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-3
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
TIA/EIA-222-F - 70 mph/61 mph 0.5000 in Ice Maximum Values
Vx Vz Mx Mz
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
0 50 0 5000 10000
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-4
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
TIA/EIA-222-F - Service - 50 mph Maximum Values
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-5
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
Feedline Distribution Chart
0' - 300'
Round Flat App In Face App Out Face Truss Leg
300'
Face A Face B Face C 300'
240' 240'
220' 220'
180' 180'
Elevation (ft)
(12) 1 5/8
140' 140'
(12) 1 5/8
(2) EW63 (to Proposed Antennas)
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
10' 10'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
Feedline Plan
(12)Ladder
Feedline 1 5/8
B
A
C
1 der
uit
5/8
nd
2) d
(1e La
Co
lin
gid
ed
Ri
Fe
2"
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-7
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
Stress Distribution Chart
0' - 300'
> 100% 90%-100% 75%-90% 50%-75% < 50% Overstress
300'
Face A Face B Face C 300'
280' 280'
260' 260'
240' 240'
220' 220'
200' 200'
180' 180'
Elevation (ft)
160' 160'
140' 140'
120' 120'
100' 100'
80' 80'
60' 60'
40' 40'
20' 20'
0' 0'
Hodge Design Associates, P.C. Job: Structural Analysis Report -- 300' Self-Supporting Tower (HDA Project No. 04S-9999)
Project: Henderson, Henderson County, KY --- Existing Tower With Proposed Modifications
22 Chestnut Street
Client:
Evansville, Indiana 47713-1022 ABC Towers and Tower Maintenance Drawn by: Gray Hodge App'd:
Code: Date: Scale:
www.hodgedesign.com Phone: 812.422.2558 TIA/EIA-222-F 07/23/04 NTS
Path: Dwg No.
FAX: 812.422.3337 E-8
C:\Documents and Settings\ghodge.HODGEDESIGN.000\My Documents\ERITower Project Data Files\Sample Reports\Sample-SS-R3.eri
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 1 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
The main tower is a 3x free standing tower with an overall height of 300' above the ground line.
The base of the tower is set at an elevation of 0' above the ground line.
The face width of the tower is 4' at the top and 26' at the base.
This tower is designed using the TIA/EIA-222-F standard.
The following design criteria apply:
Tower is located in Henderson County, Kentucky.
Basic wind speed of 70 mph.
Nominal ice thickness of 0.5000 in.
Ice density of 56 pcf.
A wind speed of 61 mph is used in combination with ice.
Temperature drop of 75 °F.
Deflections calculated using a wind speed of 50 mph.
EXISTING TOWER WITH PROPOSED MODIFICATIONS.
It is assumed that the tower has been properly maintained and is in good condition..
It is assumed that there have been no structural modifications to the tower unless specifically noted otherwise..
There are no known structural defects and that there is no structural deterioration..
All welds and bolted connections are assumed capable of developing the member strength, unless noted otherwise..
Material strengths are as noted elsewhere in this report..
This structural analysis is based on information provided by others and assumed to be reliable and correct..
See Sheet E-7 for Feedlines and Linear Appurtenances..
See Sheet E-8 for Code Check/Stress Distribution..
A non-linear (P-delta) analysis was used.
Pressures are calculated at each section.
Stress ratio used in tower member design is 1.333.
Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered.
Options
Consider Moments - Legs Distribute Leg Loads As Uniform v Treat Feedline Bundles As Cylinder
Consider Moments - Horizontals Assume Legs Pinned Use ASCE 10 X-Brace Ly Rules
Consider Moments - Diagonals v Assume Rigid Index Plate v Calculate Redundant Bracing Forces
Use Moment Magnification v Use Clear Spans For Wind Area v Ignore Redundant Members in FEA
v Use Code Stress Ratios v Use Clear Spans For KL/r v SR Leg Bolts Resist Compression
v Use Code Safety Factors - Guys v Retension Guys To Initial Tension v All Leg Panels Have Same Allowable
Escalate Ice Bypass Mast Stability Checks Offset Girt At Foundation
Always Use Max Kz v Use Azimuth Dish Coefficients v Consider Feedline Torque
Use Special Wind Profile v Project Wind Area of Appurt. v Include Angle Block Shear Check
Include Bolts In Member Capacity Autocalc Torque Arm Areas Poles
v Leg Bolts Are At Top Of Section v SR Members Have Cut Ends v Include Shear-Torsion Interaction
v Secondary Horizontal Braces Leg v Sort Capacity Reports By Component Always Use Sub-Critical Flow
Use Diamond Inner Bracing (4 Sided) v Triangulate Diamond Inner Bracing Use Top Mounted Sockets
Add IBC .6D+W Combination
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 2 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Wind 180
Leg A
Wind 90
Fa
A
ce
ce
B
Fa X
Leg C Z Leg B
Face C
Wind Normal
Triangular Tower
Tower Tower Diagonal Bracing Has Has Top Girt Bottom Girt
Section Elevation Spacing Type K Brace Horizontals Offset Offset
End
ft ft Panels in in
T1 300'-280' 3'2-17/32'' X Brace No No 4.5000 4.5000
T2 280'-260' 3'2-17/32'' X Brace No No 4.5000 4.5000
T3 260'-240' 6'2-1/32'' X Brace No No 9.0000 9.0000
T4 240'-220' 6'2-1/32'' X Brace No No 9.0000 9.0000
T5 220'-200' 6'2-1/32'' X Brace No No 9.0000 9.0000
T6 200'-180' 6'2-1/32'' X Brace No No 9.0000 9.0000
T7 180'-160' 6'2-1/32'' X Brace No No 9.0000 9.0000
T8 160'-140' 6'2-1/32'' X Brace No Yes 9.0000 9.0000
T9 140'-120' 6'2-1/32'' X Brace No No 9.0000 9.0000
T10 120'-100' 6'2-1/32'' X Brace No No 9.0000 9.0000
T11 100'-80' 6'2-1/32'' X Brace No Yes 9.0000 9.0000
T12 80'-60' 6'2-1/32'' X Brace No No 9.0000 9.0000
T13 60'-40' 6'2-1/32'' X Brace No Yes 9.0000 9.0000
T14 40'-20' 6'2-1/32'' X Brace No No 9.0000 9.0000
T15 20'-0' 6'2-1/32'' X Brace No No 9.0000 9.0000
Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle
Elevation Area Thickness Af Factor Stitch Bolt Stitch Bolt
(per face) Ar Spacing Spacing
Diagonals Horizontals
ft ft2 in in in
T13 60'-40' 2.50 0.7500 A36 1.01 1.01 1.01 36.0000 36.0000
(36 ksi)
T14 40'-20' 2.50 0.7500 A36 1.01 1.01 1.01 36.0000 36.0000
(36 ksi)
T15 20'-0' 2.50 0.7500 A36 1.01 1.01 1.01 36.0000 36.0000
(36 ksi)
Tower Leg Diagonal Top Girt Bottom Girt Mid Girt Long Horizontal Short Horizontal
Elevation
ft
Net Width U Net Width U Net Width U Net U Net U Net U Net U
Deduct Deduct Deduct Width Width Width Width
in in in Deduct Deduct Deduct Deduct
in in in in
T1 300'-280' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T2 280'-260' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T3 260'-240' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T4 240'-220' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T5 220'-200' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T6 200'-180' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T7 180'-160' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T8 160'-140' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T9 140'-120' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T10 120'-100' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T11 100'-80' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T12 80'-60' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T13 60'-40' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T14 40'-20' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
T15 20'-0' 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75 0.0000 0.75
Dishes
Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside Aperture Weight
or Type Type Horz Adjustment Beam Diameter Area
Leg Lateral Width
Vert
ft ° ° ft ft ft2 K
UHX8-59 A Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Leg 0' 1/2'' Ice 51.29 0.51
0'
UHX8-59 C Paraboloid From 1.00 0.0000 200' 8.00 No Ice 50.26 0.25
(Proposed) w/Shroud (HP) Face 0' 1/2'' Ice 51.29 0.51
0'
Load Combinations
Comb. Description
No.
1 Dead Only
2 Dead+Wind 0 deg - No Ice
3 Dead+Wind 30 deg - No Ice
4 Dead+Wind 60 deg - No Ice
5 Dead+Wind 90 deg - No Ice
6 Dead+Wind 120 deg - No Ice
7 Dead+Wind 150 deg - No Ice
8 Dead+Wind 180 deg - No Ice
9 Dead+Wind 210 deg - No Ice
10 Dead+Wind 240 deg - No Ice
11 Dead+Wind 270 deg - No Ice
12 Dead+Wind 300 deg - No Ice
13 Dead+Wind 330 deg - No Ice
14 Dead+Ice+Temp
15 Dead+Wind 0 deg+Ice+Temp
16 Dead+Wind 30 deg+Ice+Temp
17 Dead+Wind 60 deg+Ice+Temp
18 Dead+Wind 90 deg+Ice+Temp
19 Dead+Wind 120 deg+Ice+Temp
20 Dead+Wind 150 deg+Ice+Temp
21 Dead+Wind 180 deg+Ice+Temp
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 12 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Comb. Description
No.
22 Dead+Wind 210 deg+Ice+Temp
23 Dead+Wind 240 deg+Ice+Temp
24 Dead+Wind 270 deg+Ice+Temp
25 Dead+Wind 300 deg+Ice+Temp
26 Dead+Wind 330 deg+Ice+Temp
27 Dead+Wind 0 deg - Service
28 Dead+Wind 30 deg - Service
29 Dead+Wind 60 deg - Service
30 Dead+Wind 90 deg - Service
31 Dead+Wind 120 deg - Service
32 Dead+Wind 150 deg - Service
33 Dead+Wind 180 deg - Service
34 Dead+Wind 210 deg - Service
35 Dead+Wind 240 deg - Service
36 Dead+Wind 270 deg - Service
37 Dead+Wind 300 deg - Service
38 Dead+Wind 330 deg - Service
Maximum Reactions
Location Condition Gov. Vertical Horizontal, X Horizontal, Z
Load K K K
Comb.
Leg C Max. Vert 10 375.17 24.27 -14.08
Max. Hx 10 375.17 24.27 -14.08
Max. Hz 16 -226.76 -18.39 12.51
Min. Vert 4 -305.09 -21.01 12.27
Min. Hx 17 -259.77 -21.33 12.39
Min. Hz 10 375.17 24.27 -14.08
Leg B Max. Vert 6 375.27 -24.30 -14.04
Max. Hx 25 -259.81 21.35 12.35
Max. Hz 26 -226.80 18.43 12.43
Min. Vert 12 -304.99 21.03 12.23
Min. Hx 6 375.27 -24.30 -14.04
Min. Hz 6 375.27 -24.30 -14.04
Leg A Max. Vert 2 382.81 -0.04 28.55
Max. Hx 10 -156.07 3.42 -12.87
Max. Hz 2 382.81 -0.04 28.55
Min. Vert 8 -312.91 0.05 -24.88
Min. Hx 6 -156.07 -3.37 -12.87
Min. Hz 21 -265.92 0.05 -25.09
Solution Summary
Sum of Applied Forces Sum of Reactions
Load PX PY PZ PX PY PZ % Error
Comb. K K K K K K
1 0.00 -81.59 0.00 0.00 81.59 0.00 0.000%
2 0.00 -81.59 -47.12 0.00 81.59 47.12 0.005%
3 21.41 -81.59 -38.75 -21.40 81.59 38.74 0.005%
4 36.42 -81.59 -22.40 -36.42 81.59 22.39 0.004%
5 43.30 -81.59 0.00 -43.30 81.59 0.00 0.005%
6 39.47 -81.59 24.16 -39.47 81.59 -24.15 0.005%
7 21.41 -81.59 38.75 -21.40 81.59 -38.74 0.005%
8 0.00 -81.59 43.60 0.00 81.59 -43.60 0.004%
9 -21.41 -81.59 38.75 21.40 81.59 -38.74 0.005%
10 -39.47 -81.59 24.16 39.47 81.59 -24.15 0.005%
11 -43.30 -81.59 0.00 43.30 81.59 0.00 0.005%
12 -36.42 -81.59 -22.40 36.42 81.59 22.39 0.004%
13 -21.41 -81.59 -38.75 21.40 81.59 38.74 0.005%
14 0.00 -119.05 0.00 -0.00 119.05 0.00 0.000%
15 0.00 -119.05 -44.29 0.00 119.05 44.29 0.003%
16 19.59 -119.05 -35.21 -19.59 119.05 35.21 0.003%
17 32.90 -119.05 -20.04 -32.90 119.05 20.04 0.003%
18 39.55 -119.05 0.00 -39.55 119.05 0.00 0.003%
19 37.33 -119.05 22.60 -37.33 119.05 -22.60 0.003%
20 19.59 -119.05 35.21 -19.59 119.05 -35.21 0.003%
21 0.00 -119.05 39.18 0.00 119.05 -39.18 0.003%
22 -19.59 -119.05 35.21 19.59 119.05 -35.21 0.003%
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 14 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Compression Checks
T10 120 - 100 3 3/4 20'1/4'' 6'2-1/32'' 79.0 19.206 11.0447 -274.94 212.13 1.296
K=1.00
T11 100 - 80 3 3/4 20'1/4'' 3'1-9/16'' 40.1 25.819 11.0447 -296.31 285.17 1.039
K=1.00
T12 80 - 60 4 20'1/4'' 6'2-1/32'' 74.1 20.168 12.5664 -318.08 253.44 1.255
K=1.00
T13 60 - 40 4 20'1/4'' 3'1-7/16'' 37.5 26.178 12.5664 -340.32 328.96 1.035
K=1.00
T14 40 - 20 4 1/4 20'1/4'' 6'2-1/32'' 69.7 20.988 14.1863 -362.54 297.74 1.218
K=1.00
T15 20 - 0 4 1/4 20'1/4'' 6'2-1/32'' 69.7 20.988 14.1863 -383.68 297.74 1.289
K=1.00
Tension Checks
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 19 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
T4 240 - 220 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 130.70 248.87 0.525
T5 220 - 200 3 1/4 20'1/4'' 6'2-1/32'' 91.2 30.000 8.2958 149.34 248.87 0.600
T6 200 - 180 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 171.10 288.63 0.593
T7 180 - 160 3 1/2 20'1/4'' 6'2-1/32'' 84.7 30.000 9.6211 190.23 288.63 0.659
T8 160 - 140 3 1/2 20'1/4'' 3'1- 43.2 30.000 9.6211 207.89 288.63 0.720
13/16''
T9 140 - 120 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 224.72 331.34 0.678
T10 120 - 100 3 3/4 20'1/4'' 6'2-1/32'' 79.0 30.000 11.0447 240.55 331.34 0.726
T11 100 - 80 3 3/4 20'1/4'' 3'1-9/16'' 40.1 30.000 11.0447 255.81 331.34 0.772
T14 40 - 20 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 299.21 425.59 0.703
T15 20 - 0 4 1/4 20'1/4'' 6'2-1/32'' 69.7 30.000 14.1863 313.82 425.59 0.737
T2 280 - 260 7/8 5'1-9/16'' 2'5- 134.8 21.600 0.6013 4.81 12.99 0.370
17/32''
T3 260 - 240 L2x2x3/16 7'6-3/8'' 3'9- 74.0 21.600 0.7150 5.37 15.44 0.347
19/32''
T4 240 - 220 L2x2x3/16 8'7-7/16'' 4'3- 83.9 21.600 0.7150 3.80 15.44 0.246
27/32''
T5 220 - 200 L2x2x3/16 10'8- 5'4-3/16'' 104.0 21.600 0.7150 3.58 15.44 0.232
17/32''
Job Page
ERITower Structural Analysis Report -- 300' Self-Supporting Tower (HDA 20 of 22
Project No. 04S-9999)
Project Date
Hodge Design Associates, P.C.
22 Chestnut Street Henderson, Henderson County, KY --- Existing Tower With 13:04:30 07/23/04
Proposed Modifications
Evansville, Indiana 47713-1022 Client Designed by
Phone: 812.422.2558 ABC Towers and Tower Maintenance
FAX: 812.422.3337 Gray Hodge
Program Version 3.0.0.16 - 7/10/2004 File:C:/Documents and Settings/ghodge.HODGEDESIGN.000/My Documents/ERITower Project Data Files/Sample
Reports/Sample-SS-R3.eri
APPENDIX E
Suggested Recommendations for Tower Reinforcement