Вы находитесь на странице: 1из 1

S06,S09 & S12 Selection Chart

S06, S09 & S12


Dimensional Drawing
SCHEMATIC 3/2 NC

68 86.5

50
T
34

TYPE ‘M’
OVERRIDE
OPTION

3
2

M20 x 1.5P EXTERNAL


CABLE ENTRY EARTH STUD
36.4
212.5

MOUNTING POSITIONS
3 x Ø5.2 THRO' HOLES SCHEMATIC 3/2 NO
187.9
157.1

=
38

T
=

VIEW OF DETAIL 'A'


1/8" NPT
PILOT VENT 20.7
50.8

52.2

DETAIL A 1 2 3
3
36.3 2
50.8 52.2
67.4
125.3 1

S06/S09/S12 Selection Chart - Ordering Example


S06 ¼" NPT
S09 3⁄8" NPT Model Code
S12 ½" NPT
E1 Internal Pilot - Auto Reset E13 Internal Pilot electrical and manual required to
E2 External Pilot - Auto Reset latch - tamperproof
E3 Manual Override - Electrical to switch E14 External Pilot electrical and manual required to
OR temporary manual override latch - tamperproof Primary Actuator
E4 External Pilot - Manual Override E15 Internal Pilot Manual Override Rotary - Electrical
E5 Manual reset - Electrical AND manual required to switch OR temporary manual override
to latch OR temporary manual override E16 External Pilot Manual Override Rotary - Electrical
E6 External Pilot - Manual Reset to switch OR temporary manual override
22 2 - way, 2 - position
52 5 - way, 2 - position Valve Configuration
32 3 - way, 2 - position
NC Normally Closed NO Normally Open Valve Configuration
XX 52 Valves Only
00 Spring return end cap 03 Spring cap with mechanical latch
02 Spring cap with E1 Internal Pilot Secondary Actuator
microswitch plunger
XX Refer to Solenoid options tables. 74 (Ex emb) Page 12 - Table 1
77 (Ex d) Page 13 - Table 2 Solenoid *
78 (Ex ia) Page 14 - Table 3 **
74(Ex emb) 77(Ex d) 78(Ex ia)
A ATEX/IECEx Dual Certified/Labelled   
G GOST x   Solenoid Approval
I INMETRO x  
N NEPSI* x  x
U CSA (US) ATEX Dual Certified/Labelled x  x
XXX Voltage, refer 74 (Ex emb) Page 12 - Table 1
to Solenoid 77 (Ex d) Page 13 - Table 2 Voltage
option tables.
XX Power (W) 74 (Ex emb) - 1.8 & 3.6 Watts Page 12 - Table 1 Power
77 (Ex d) - 1.5 & 3.0 Watts Page 13 - Table 2
XX Resistance (Ω) 78 (Ex ia) - 370 Ohms Page 14 - Table 3 Resistance
K6 BSPP ports Option
K85 ½" NPT conduit entry Option

S06 E1 32 NC 00 77 A 24D 30 K6 K85 Ordering Example


For green block sections, please refer to the same colour section on pages 12, 13 or 14.
* For China (NEPSI), please note that the solenoid operator is Type 87.
** Special conditions for safe use Type 74 - The supply circuit shall be fitted with a fuse capable of meeting a 1500 mA short circuit current.
Accuracy of information
We take care to ensure that product information in this
catalogue is reasonably accurate and up-to-date. However,
our products are continually developed and updated
so to ensure accurate and up-to-date information please Quality Assurance
refer to the product catalogue issue list on our web site or All Bifold products are manufactured to a most stringent
is a member of the
www.bifold.co.uk contact a member of our sales team.

When selecting a product, the applicable operating system


QA programme to ensure that every product will give optimum
performance and reliability. We are third party certified to
BS EN ISO 9001:2008. Functional test certificate, letter of
21
design must be considered to ensure safe use. The products conformity and copies of original mill certificates, providing of companies
function, material compatibility, adequate ratings, correct total traceability are available on request, to BS EN 10204 3.1
installation, operation and maintenance are the where available. We reserve the right to make changes
to the specifications and design etc., without prior notice.
BFD15/2 December ‘12 responsibilities of the system designer and user.
© Bifold 2012