Вы находитесь на странице: 1из 4

Step N.

Start Sequence Step Steps Details

- Trip reset
01 From zero-speed to 1st IDLE - Selector to IDLE position
- Permissive to start verification
- Start command

02 IDLE in progress - Speed at 1500 rpm

- IDLE time expired


03 From IDLE speed to critical band - Selector in RATED position
- Speed between 1500 - 2500 rpm

04 Speed in critical band - Speed between 2500 - 3500 rpm

05 From critical band to rated - Speed between 3500 - 5950 rpm

- Speed above 5950 rpm


06 Start sequence ended - Speed SP Raise/Lower command enabled
- External SP command from Customer enabled

Step N. Normal Stop Sequence Steps Steps Details

- Normal stop command


01 To minimum operative speed - From operative point to rated speed
- Anti-surge opening

02 Unload (External SP disabled) - Speed between 5950 - 3500 rpm

03 In critical band - Speed between 3500 - 2500 rpm

04 From critical band to IDLE speed - Speed between 2500 - 1500 rpm

05 At IDLE speed - Speed at 1500 rpm

06 Turbine trip - Turbine is tripped as soon as speed SP reaches IDLE


Normal Stop Command Halt

- Turbine is tripped - SP is halted

- SP remains halted even if IDLE time is


- Turbine is tripped
finished

- Normal stop sequence begins (step 04)


- Turbine decreases the speed SP till IDLE - SP is halted
speed

- Normal stop sequence begins (step 03) - Halt command is disabled within the critical
- Turbine SP decreases and passes the critical band
band - SP continues to raise to pass the critical
- Turbine decreases the speed SP till IDLE band
speed - SP is halted once critical band is finished

- Normal stop sequence begins (step 02)


- SP is halted
- Turbine SP decreases till critical band

- SP is halted if external SP command from


- Normal stop sequence begins (step 01)
Customer is selected
- Turbine SP decreases till rated speed
- Halt command is not active if external SP
- ASV opens
command from Customer is not selected

Start Command Halt

- Command is not available - SP is halted

- Command is not available - SP is halted

- Halt command is disabled


- SP continues to decrease to pass the critical
- Command is not available
band
- SP is halted once critical band is finished

- Command is not available - SP is halted

- SP is halted eve if RATED mode is selected


- Command is not available in case IDLE mode has been previously
selected
Continue Selector in IDLE position

- Turbine in IDLE mode


- SP is continued
- Turbine continues to raise SP till IDLE

- SP increases after an halt command is given - Turbine in IDLE mode


only if RATED mode has been previously - Turbine is halted in IDLE mode also at the
selected end of IDLE time

- Turbine in IDLE mode


- Normal stop sequence begins (step 04)
- Turbine decreases the speed SP till IDLE
- SP is continued
speed
- Turbine will remain at IDLE speed without
tripping

- Turbine in IDLE mode


- Normal stop sequence begins (step 03)
- Command not applicable since Halt - Turbine decreases the speed SP till exiting
command is not active from critical band
- Turbine will remain at IDLE speed without
tripping

- Turbine in IDLE mode


- Normal stop sequence begins (step 02)
- SP is continued - Turbine SP decreases till critical band
- Turbine will remain at IDLE speed without
tripping

- Turbine in IDLE mode


- SP is continued if halt command has been - Normal stop sequence begins (step 01)
previously sent - Turbine SP decreases till rated speed
- ASV opens

Continue Selector in IDLE position

- Normal stop sequence is disengaged


- Turbine continues to raise SP till Customer
SP if external SP command from Customer is
selected - Turbine in IDLE mode
- Turbine remains halted at current SP is
external SP command from Customer is not
selected

- Start sequence is resumed (step 05)


- Turbine increases the speed SP till rated - Turbine in IDLE mode
speed

- Command not applicable since Halt


- Turbine in IDLE mode
command is not active

- Start sequence is resumed (step 03)


- Turbine increases the speed SP till critical - Turbine in IDLE mode
band

- Turbine in IDLE mode


- SP is continue after switching in RATED
- If IDLE mode has been previously selected,
mode
turbine remains at IDLE speed
Selector in RATED position Trip

- Turbine in RATED mode


- Turbine is tripped
- Turbine continues to raise SP till IDLE

- Turbine in RATED mode


- Turbine continues to raise the speed SP - Turbine is tripped
once IDLE time is finished

- Turbine in RATED mode


- Turbine is tripped
- Turbine continues to raise SP till cirtical band

- Turbine in RATED mode


- Turbine continues to raise SP till exit from - Turbine is tripped
critical band

- Turbine in RATED mode


- Turbine is tripped
- Turbine continues to raise SP till rated speed

- Turbine in RATED mode


- Turbine continues to raise SP till Customer
SP if external SP command from Customer is
selected - Turbine is tripped
- Turbine remains halted at current SP is
external SP command from Customer is not
selected

Selector in RATED position Trip

- Turbine in RATED mode - Turbine is tripped

- Turbine in RATED mode - Turbine is tripped

- Turbine in RATED mode - Turbine is tripped

- Turbine in RATED mode - Turbine is tripped

- Turbine in RATED mode


- If IDLE mode has been previously selected,
- Turbine is tripped
turbine is resumed and starts to raise SP till