Академический Документы
Профессиональный Документы
Культура Документы
Fan Selection
Fan Type
Unit TDA1250-V-25BJ-8-8 / 26°
Operating Conditions Ducted
Required Volume 60,000 m³/h
Required Static Pressure 600 Pa
Air Volume 60,765 m³/h
Static Pressure 615 Pa
Velocity Pressure 114 Pa
Total Pressure 729 Pa
Outlet Velocity 13.75 m/s
Fan Total Efficiency 64.2 %
Fan Static Efficiency 54.2 %
Fan Speed 950 rpm
Air Temperature 20 °C
Altitude 0m
Fan Absorbed Power 19.2 kW
Motor Selection
Recommended Motor D200L (22.0 kW)
Motor Speed 960 rpm
Service Factor 5%
Operating Limits
Max. Absorbed Power -
Max. Fan Speed -
Temperature (Min-Max) -
Fan Selection
Fan Type
Unit BSB900/UIM (I)
Operating Conditions Ducted
Air Volume 30,000 m³/h
Static Pressure 1,000 Pa
Velocity Pressure 92 Pa
Total Pressure 1,092 Pa
Outlet Velocity 12.39 m/s
Fan Total Efficiency 75.3 %
Fan Static Efficiency 68.9 %
Fan Speed 1024 rpm
Air Temperature 20 °C
Altitude 0m
Fan Absorbed Power 12.1 kW
Motor Selection
Recommended Motor D160L (15.0 kW)
Motor Speed 1450 rpm
Service Factor 10 %
Operating Limits
Max. Absorbed Power 14.00 kW
Max. Fan Speed 1050 rpm
Temperature (Min-Max) -20° to 180°C
C H KG L W
1293 1728 346 2000 1390