Вы находитесь на странице: 1из 4

Isolated Footing Design Page 7 of 986

Input Values
Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 450.000 mm
Footing Length - X (Fl) : 500.000 mm
Footing Width - Z (Fw) : 500.000 mm
Eccentricity along X (Oxd) : 0.000 mm
Eccentricity along Z (Ozd) : 0.000 mm

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 0.400 m
Column Width - Z (Pw) : 0.400 m

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters
Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 8/6/2016
Isolated Footing Design Page 8 of 986

Unit Weight of Concrete : 24.000 kN/m3


Strength of Concrete : 25.000 N/mm2
Yield Strength of Steel : 250.000 N/mm2
Minimum Bar Size : T16
Maximum Bar Size : T25
Minimum Bar Spacing : 50.000 mm
Maximum Bar Spacing : 500.000 mm
Pedestal Clear Cover (P, CL) : 50.000 mm
Footing Clear Cover (F, CL) : 50.000 mm

Soil Properties

Soil Type : Drained


Unit Weight : 18.000 kN/m3
Soil Bearing Capacity : 300.000 kN/m2
Soil Surcharge : 0.000 kN/m2
Depth of Soil above Footing : 2100.000 mm
Cohesion : 0.000 kN/m2
Min Percentage of Slab : 0.000

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Initial Footing Dimensions

Footing Thickness (Ft) : 450.000 mm


Footing Length - X (Fl) : 500.000 mm
Footing Width - Z (Fw) : 500.000 mm

------------------------------------------------------

Design Calculations

Reduction of force due to buoyancy = 0.000 kN


Effect due to adhesion = 0.000 kN

Area from initial length and width, Ao = Lo * Wo = 0.250 m 2


Min. area required from bearing pressure, Amin = P / qmax = 0.242 m 2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
4 GENERATED BRITISH BS 8110 1
5 GENERATED BRITISH BS 8110 2
6 GENERATED BRITISH BS 8110 3
Load Combination/s- Strength Level

Load Combination Load Combination Title

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 8/6/2016
Isolated Footing Design Page 9 of 986

Number
4 GENERATED BRITISH BS 8110 1
5 GENERATED BRITISH BS 8110 2
6 GENERATED BRITISH BS 8110 3

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
4 66.627 -7.279 -0.412 -0.475 10.304
5 50.344 -0.725 4.031 2.642 0.992
6 52.730 -2.459 3.378 2.184 3.422

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kN) (kN) (kN) (kNm) (kNm)
4 66.627 -7.279 -0.412 -0.475 10.304
5 50.344 -0.725 4.031 2.642 0.992
6 52.730 -2.459 3.378 2.184 3.422

Final Footing Dimensions

Length (L2) = 1.300 m Governing Load Case : #4

Width (W2) = 1.300 m Governing Load Case : #4

Depth (D2) = 0.450 m Governing Load Case : #4

Area (A2) = 1.690 m2

Calculated Pressures At Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kN/m2) (kN/m2) (kN/m2) (kN/m2) (m2)

4 123.3354 49.1618 45.5562 119.7299 0.000

5 66.2412 59.0434 83.3797 90.5776 0.000

5 66.2412 59.0434 83.3797 90.5776 0.000

4 123.3354 49.1618 45.5562 119.7299 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative
pressure will be set to zero and the pressure will be redistributed to remaining corners.

Summary Of Adjusted Pressures At Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)
Load Case (kN/m2) (kN/m2) (kN/m2) (kN/m2)

4 123.3354 49.1618 45.5562 119.7299

5 66.2412 59.0434 83.3797 90.5776

5 66.2412 59.0434 83.3797 90.5776

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 8/6/2016
Isolated Footing Design Page 10 of 986

4 123.3354 49.1618 45.5562 119.7299

Detail of Out-of-contact Area

Maximum Out-of-contact Area = 0.000 sq.m


Plan Area of Footing = 1.690 sq.m
Ratio of Out-of-contactArea = 0.000%

Overturning and Sliding

- Factor of safety against sliding Factor of safety against overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

4 9.804 173.295 140.526 6.831

5 87.230 15.682 18.444 62.361

6 26.190 19.066 22.604 18.488

Critical load case and the governing factor of safety for overturning and sliding -X Direction

Critical Load Case for Sliding along X-Direction : 4


Governing Disturbing Force : -7.279 kN
Governing Restoring Force : 71.357 kN
Minimum Sliding Ratio for the Critical Load Case : 9.804
Critical Load Case for Overturning about X-Direction : 5
Governing Overturning Moment : 4.455 kNm
Governing Resisting Moment : 82.178 kNm
Minimum Overturning Ratio for the Critical Load Case : 18.444

Critical load case and the governing factor of safety for overturning and sliding -Z Direction

Critical Load Case for Sliding along Z-Direction : 5


Governing Disturbing Force : 4.031 kN
Governing Restoring Force : 63.215 kN
Minimum Sliding Ratio for the Critical Load Case : 15.682
Critical Load Case for Overturning about Z-Direction : 4
Governing Overturning Moment : 13.580 kNm
Governing Resisting Moment : 92.762 kNm
Minimum Overturning Ratio for the Critical Load Case : 6.831

Check For Trial Depth against moment about Z Axis

(Shear Plane Parallel to Z axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 8/6/2016