Вы находитесь на странице: 1из 4

Measuring Principle Comparison

Level
Continuous / Liquids
22.10.2017 05:07 PM
Measuring principle Level radar Guided radar Ultrasonic
Image

Application Liquids Liquids Liquids


Preferences Non-contact measurement with Measurement with preadjusted Non-contact measurement with
no wear and tear measuring range no wear and tear
Safe to use with gas-generating Measurement of liquids is No calibration with the medium
media and production of vapour not affected by surface foam, required
Not affected by changing media, obstructions or false reflections Not affected by changing media,
e.g variations °F conductivity e.g. variations in density
Reliable and proven technology Cost effective, reliable and proven
technology
Process temperature -60 °C ... 450 °C -196 °C ... 450 °C -40 °C ( -40°F) ... 135 °C (275 °F)
(–321 °F...+842 °F)
Process pressure absolute / max. Vacuum ... 160 bar Vacuum ... 400 bar 0.7 bar abs ... 4 bar abs
overpressure limit (10 psi ... 58 psi)
Measuring range 0.3 m ... 70 m 0.2 m (0.6ft)...45 m (148 ft) 0.07 m (0.23 ft) ... 25 m (85 ft)
Function may be influenced by Foam Extreme build-up Foam
Extreme turbulent / boiling Extreme foam Extreme turbulent surface
surface Build-up / strong condensate at
Conductive build-up at antenna the sensor or in the nozzle
Application limits Measurement to abs. 0% 1) Measurement to abs. 0% 2) Measurement to abs. 0% 1)
DK ( Er )< 1.4 DK ( Er ) < 1.4 Media with vapor pressure > 50
Bottom installation Agitator blades mbar ( 20 °C )
Bottom installation Blocking distance
Bottom / side installation
Accuracy 6 GHz : < 10 m : +/- 6 mm Rod probe :+/- 2 mm (0.08 in) +/- 2mm + 0.17% of measured
26 GHz : < 10 m : +/- 2 mm Rope probe <= 15 m (49 ft): +/- 2 distance
mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10
mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
Accuracy may be influenced by Weak echoes caused by moving Weak echoes caused by moving The gas composition may
surface, small DK ( Er ),... surface, small DK ( Er ),... influence the sound velocity
Tank wall effects, false echoes False echoes considerably
Temperature layers in the gas
above the medium
Weak echoes caused by moving
surface,...
False echoes

1/4
Measuring Principle Comparison
Level
Continuous / Liquids
22.10.2017 05:07 PM
Measuring principle Capacitive Hydrostatic Differential pressure
Image

Application Liquids Liquids Liquids


Preferences Accurate measurement of very Not affected by surface foam or Not affected by surface foam or
small measurement ranges tank installations tank installations
Interface measurement possible Easy planning Easy planning
Cost effective, reliable and proven Reliable proven technology Reliable, proven technology
technology
Process temperature -200 °C ... 400 °C -70...400°C/ -94...+752°F -70°C...+400°C
(-94...+752°F)
Process pressure absolute / max. Vacuum ... 500 bar 1050bar 420bar
overpressure limit
Measuring range 0.1 m ... 20 m 100mbar ... 700bar 10mbar ... 40bar
Function may be influenced by Plastic vessel Hardening build-up Hardening build-up
Build-up or foam Density variations of the medium Density variations of the medium
Dynamic pressure caused by Dynamic pressure of agitators
agitor resp. vortex and squinches
Application limits Measurement to abs. 0% 2) Hardening build-up Hardening build-up
DK ( Er ) < 2.0 Vacuum and temperatures > Aggressive media
Agitator blades 200°C at the same time
Changing media with Lf < 200
us / cm
Calibration with process medium
necessary
Accuracy +/- 1 % +/- 0,075% (0,05%) +/- 0,075% (0,05%)
Accuracy may be influenced by LF < 200 us / cm : variable Changing density Changing density
dielectric constant Tk with capillaries and remote Tk with capillaries and remote
LF > 200 us / cm : high pressure / seals [ process temperature, seals [process temperature,
temperature with PTFE - isolation ambient temperature ] ambient temperature]

2/4
Measuring Principle Comparison
Level
Continuous / Liquids
22.10.2017 05:07 PM
Measuring principle Radiometric Servo / Float Tank Gauging Gauge pressure
Image

Application Liquids Liquids general_selection_


Preferences Contactless measurement Absolute measurement general_selection_
Accurate measurement under Level, interface and density
extreme conditions, e.g. toxicity, profile measurement with only
abrasion, aggressiveness one sensor
Interface and density Reliable and proven technology
measurement possible Low maintenance
Communications output up to 6
km
Process temperature Any -200 °C ... 200 °C   general_selection_
Process pressure absolute / max. Any Vacuum ... 25 bar general_selection_
overpressure limit
Measuring range < 2 m / 4 m / 6 m / 8m / 10m 0 m ... 36 m   general_selection_
Function may be influenced by general_selection_ Foam general_selection_
Extreme turbulence / boiling
surface
Build-up on displacer/measuring
wire
Application limits general_selection_ Process connection > 3"/ DN80 general_selection_
0.500 g/cm3 < Density < 2.000 g/
cm3
Accuracy general_selection_ Liquid level: +/- 0.7 mm general_selection_
Liquid Interface: +/- 2.7 mm
Density: +/- 0.005 g/cm3
Accuracy may be influenced by Physically created statistical Turbulence general_selection_
variations of the measuring Vibration
equipment Displacer type
Variations in density may lead to
incorrect measurements in small
containers (< 500mm)
High pressure may cause
variations in gas density

3/4
Measuring Principle Comparison
Level
Continuous / Liquids
22.10.2017 05:07 PM
Measuring principle Absolute and gauge pressure
Image
Application
Preferences
Process temperature
Process pressure absolute / max.
overpressure limit
Measuring range
Function may be influenced by
Application limits
Accuracy
Accuracy may be influenced by

4/4