User Instructions
1
Model 498KL
Thank you for your purchase of this Health o meter® Professional product. Please read this
manual carefully, and keep it for easy reference or training.
TABLE OF CONTENTS
Note: This scale has been factory calibrated, and does not
require calibration prior to use.
3
SPECIFICATIONS FOR THIS SCALE
General
The Model 498KL remote display digital scale uses highly sophisticated microprocessor
technology. Each precision scale is designed to provide accurate, reliable and repeatable
weight measurements. In addition, each scale is designed to provide the user with features that
make the weighing process simple, fast, and convenient.
This scale is set up to use motion-sensing weighing technology in order to determine the actual
weight of a moving patient.
Weight can be displayed in pounds (lb) or in kilograms (kg). For privacy and convenience in
use, the scale features a remote display head which may be held by the operator, placed on a
table or other flat surface, or mounted on a wall. This scale can be powered using an AC
adapter (not included), or by 6 - AA batteries (included).
4
CERTIFICATIONS / CONNECTIVITY / DISPOSAL
Certification Descriptions
To enable reliable transmission of weight, height, and Body Mass Index (BMI) data, this scale is
designed to connect to a computer, monitor, or other electronic device via a built-in USB port.
This connectivity helps minimize a source of potential medical errors caused by incorrectly
copying and then recording patient data.
This scale is EMR-EHR compatible. For more information regarding how to connect this scale to
other electronic devices, please contact Health o meter® Professional Scales Technical
Support, available during normal business hours at 1-800-683-3722.
This Health o meter® Professional scale must be disposed of properly as electronic waste.
Follow the national, regional or local regulations which apply to you for disposal of electronic
waste or batteries. Do not dispose of this device in the domestic waste stream.
5
498KL ASSEMBLY INSTRUCTIONS
Before Assembly
Each 498KL remote display digital scale is shipped disassembled in one carton. Carefully
inspect the carton for shipping damage before unpacking. If damage is found, contact your
shipper or a Health o meter® Professional representative immediately at 1-800-815-6615.
Claims must be filed with the shipper as soon as possible after receipt of the package. The
following information details what you will find inside the main carton as you unpack the parts for
assembly.
To prevent scratching any components, carefully remove each assembly from the carton and
unwrap the packing materials. Set the carton aside for storage. To avoid damaging the scale
parts when unpacking, do not use a box cutter, knife, scissors, or any sharp object to open the
protective inner packaging.
Parts List
Carton
Tools Required
6
498KL ASSEMBLY INSTRUCTIONS (CONTINUED)
Note: For wall mounting, mount display assembly directly to the wall do not use display bracket
for wall mount. Display bracket is for surface use only.
1. Carefully remove the scale platform with the display assembly from the carton, and place the
scale platform and display assembly on a flat, level, and dry surface (see Figure 3).
2. Ensure that the cable is securely connected to the scale platform RJ jack (see Figures 2 & 3).
3. Remove the display bracket from the carton (see Figure 1).
4. Remove the two small screws from plate B (see Figure 1).
5. While holding plate A, slide the tab of plate B up and under the center tab on the back of plate
A (see Figure 1).
6. Align plate A and plate B, and ensure that the screw holes are lined up (see Figure 1).
7. Insert the two small screws into the front of plate A and through the holes in plate B
(see Figure 1).
8. Using a Phillips head screwdriver, tighten the screws to secure plate A to plate B
(see Figure 1).
9. Slide the two mounting studs on the display bracket into the two mounting holes in the back of
the display assembly (see Figures 1 & 4). The display bracket is now ready for use.
7
498KL ASSEMBLY INSTRUCTIONS (CONTINUED)
Display Bracket
Mounting studs
Screws
Center tab
Plate A
Screw
holes
Tab
Plate B
Figure 1
Scale platform
RJ jack
Adaptor Jack
Figure 2
8
498KL ASSEMBLY INSTRUCTIONS (CONTINUED)
Scale platform
Display assembly
RJ jack
Cable
Figure 3
9
DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS
Caution: When wall mounting the display assembly, ensure that the
mounting location is free of electrical lines, gas pipes, and other safety
hazards. Ensure that wall is of construction that can support the display
assembly.
Note: Remote head can be mounted to a wall up to 6 feet (1.83 m) from the base or it can be
mounted on the display bracket (included) for placement on a table up to 6 feet (1.83 m) from
the base.
Note: For wall mounting, mount display assembly directly to the wall do not use display bracket
for wall mount. Display bracket is for surface use only.
1. Position the display assembly on the wall, and carefully trace around the
display outline.
2. Mark a level horizontal line, 2-¾” (70 mm) below the top of the display outline.
3. Mark a vertical line 3.1” (80 mm) from each side of the display outline.
4. Use the appropriate plastic or metal anchors for the type of wall construction.
5. At the horizontal and vertical intersection, carefully drill the appropriate sized
holes.
6. Insert the anchors into the wall, and screw the two mounting screws into the
anchors. Adjust the screw head depth such that the screw heads protrude
1/8” (3.2 mm) from the wall.
Warning: Extending the screw heads beyond 1/8” (3.2 mm) can damage the
display assembly.
7. Position the display assembly mounting holes onto the mounting screws and
pull down on the display assembly to secure the bracket over the screws.
Required Parts
Note: Anchors and anchoring screws are not included with this scale.
10
DISPLAY ASSEMBLY WALL MOUNT INSTRUCTIONS
(CONT)
Display assembly
Figure 4
11
SETUP / BATTERIES / TRANSPORT
1. Remove the protective plastic film covering the display (the film says “FACTORY
CALIBRATED”).
2. Unplug the optional AC adapter, if connected to a power source.
3. Use a Phillips head screwdriver to remove the battery cover on the side of the display
assembly by unscrewing the (2) battery cover screws (see Figure 5).
4. Replace or install the batteries with new units. Health o meter recommends using an alkaline
or lithium battery, rated for 130°F (54°C) operation. Do not use zinc-carbon batteries.
5. Re-attach the battery cover to the display assembly.
6. Ensure all objects are removed from the scale’s assembly, and then press the ON/OFF
button to turn the scale on. The display will show “Start”, then “0.0” LB or “0.0” KG. Press the
LB/KG button to select the weight mode (LB or KG).
Note: This scale will always default to the settings and units last used (LB or KG).
Note: If the set up procedure failed, refer to the troubleshooting instructions. If the problem is
not corrected, refer to qualified service personnel.
Warning: If the scale will not be used for some time, remove the batteries to avoid a
safety hazard. Disposal of batteries must be performed in accordance with the prevailing
national, regional or local regulations which apply to you.
Figure 5
12
SETUP / BATTERIES / TRANSPORT (CONTINUED)
Optional AC Adapter
1. Remove the protective plastic film covering the display (the film says “FACTORY
CALIBRATED”).
2. Connect the optional AC adapter into the adaptor jack on the scale platform (see Figure 2).
Warning: To avoid a safety hazard, use AC adapter model ADPT30 (International, plug kit)
or ADPT31 (Domestic, USA).
3. Plug the scale’s AC adapter into the power source.
4. Ensure all objects are removed from the scale’s assembly. Press the ON/OFF button to turn
the scale on. The display will show “Start”, then “0.0” LB or “0.0” KG. Press the LB/KG button to
select the weight mode (LB or KG).
Note: This scale will always default to the settings and units last used (LB or KG).
5. When the AC adapter is disconnected from the scale, the scale will switch to battery power if
batteries are installed.
Note: If the set up procedure failed, refer to the troubleshooting instructions. If the problem is
not corrected, refer to qualified service personnel.
13
SETUP / BATTERIES / TRANSPORT (CONTINUED)
This scale can be easily placed into carrying case (# 64771) for storage, or transport from one
room to another. This scale does not include the carrying case item # 64771, and must be
acquired separately (see Figure 6). To prepare the scale for transport, follow these steps:
1. Remove the display assembly and display bracket from its current position.
2. Unplug the AC adapter and USB cable from the scale platform, and remove the AC adapter
from the outlet.
3. Carefully store the AC adapter, display bracket, and display assembly in carrying case to
prevent damage during transport (see Figure 7).
4. With the scale platform on the floor, lift scale platform carefully and place scale platform into
the carrying case. Position scale platform such that the adaptor jack and USB port are facing
up (see Figure 7).
5. Close carrying case flap over the scale (see Figure 6).
6. Grasp the carrying case strap and lift carefully into the upright position. Position the strap
over a shoulder (see Figure 8). The scale can now be transported.
Required Parts
Figure 6
14
SETUP / BATTERIES / TRANSPORT (CONTINUED)
Scale platform
Display assembly
Display bracket
Figure 7
Strap
Figure 8
15
QUICK START / OPERATING INSTRUCTIONS
Keypad
Figure 9
Function Description
ON/OFF Turns scale on and off.
ZERO Tares the scale prior to a weighing.
Holds the weight value of the patient on the display until the button is
HOLD/RELEASE
pressed again to clear the value.
Prompts entry of height data to calculate patient’s Body Mass Index
BMI
(BMI).
LB/KG Toggles between pounds (LB) and kilograms (KG).
CLEAR Clears the incorrect height input when in BMI mode.
UP▲ Increases height input (0.5 in / 0.5 cm increments)
DOWN▼ Decreases height input (0.5 in / 0.5 cm increments)
Used to accept height value in BMI mode. Also releases the recall value
ENTER
and BMI value.
16
QUICK START / OPERATING INSTRUCTIONS (CONT)
Auto-Off Function
As an energy saving feature, the scale will automatically turn off after 2 minutes of inactivity. By
default this function is enabled.
Note: Ensure cable is attached to the display assembly RJ jack, and make sure there is no
object on the scale platform.
Disable Auto-Off
1. While the scale is turned off, press and hold the HOLD/RELEASE button.
2. While holding the HOLD/RELEASE button, press the ON/OFF button to turn the scale on.
3. “START” will briefly appear on the display followed by “AOF=0”.
4. Auto-off is now disabled and the scale will remain on until the scale is manually turned off.
Enable Auto-Off
1. While the scale is turned off, press and hold the HOLD/RELEASE button.
2. While holding the HOLD/RELEASE button, press the ON/OFF button to turn the scale on.
3. “START” will briefly appear on the display followed by “AOF=1”.
4. Auto-off is now enabled.
Note: The default weighing mode for this scale can be changed from LB/KG to KG only or LB
only.
17
QUICK START / OPERATING INSTRUCTIONS (CONT)
Weighing a Patient
Note: When this scale is turned on, it will always default to the settings and units last used (LB
or KG).
1. Make sure there is no object on the scale platform.
2. Press the ON/OFF button to turn the display assembly on.
3. Wait until the “0.0” LB or “0.0” KG appears on the display.
4. Ask the patient to step on the scale. The scale will begin to display weight information and will
lock on the patient’s weight when the stable weight of the patient is determined. Depending on
the movement of the patient on the scale, it may take several seconds for the scale to lock onto
the weight.
Caution: To prevent patient injury, the patient must be attended throughout the entire
weighing event.
5. The weight may be held on the display by pressing the HOLD/RELEASE button. To release,
press the HOLD/RELEASE button again.
6. After the weight measurement has been taken and recorded, have the patient step off the
scale.
7. Press the ON/OFF button to turn the scale off.
BMI Function
Body Mass Index is another name for Quetelet Index, a formula that is a convenient indicator of
BMI with various exemptions, such as athletes, children, the elderly, and the infirm.
Note: The scale will not calculate BMI for a patient that is 24 pounds (12 kg) or less. If a height
is not entered for the patient within 30 seconds of pressing the BMI button, the scale will return
to the normal weighing mode.
1. Make sure there is no object on the weighing platform.
2. Press the ON/OFF button to turn the scale on.
3. Wait until the “0.0” LB or “0.0” KG appears on the display.
4. Ask the patient to step on the scale. The scale will begin to display weight information and will
lock on the patient’s weight when the stable weight of the patient is determined. Depending on
the movement of the patient on the scale, it may take several seconds for the scale to lock onto
the weight.
5. Once a weight has been displayed, while the patient is still on the scale, Health o meter
recommends performing a second weighing by pressing the REWEIGH button.
6. After obtaining the patient’s weight on the scale, press the BMI button while the scale is on.
7. The scale will prompt you to enter the patient’s height. Use the keypad ▲ and ► buttons to
enter the patient’s height.
Note: When weighing in pounds, the height is displayed in inches. When weighing in kilograms,
the height is displayed in centimeters.
8. Once height is keyed in, press the ENTER button.
9. The display will show the patient’s BMI.
10. Press the ENTER button to return to the normal weighing mode of the scale.
18
QUICK START / OPERATING INSTRUCTIONS (CONT)
Zero Function
When using this scale, the weight of an object, can be zeroed out allowing additional weight to
be added and displayed. The zero function automatically performs this subtraction.
1. With all weight off the scale, press the ON/OFF button to turn on the scale.
2. Wait until the “0.0” LB appears on the display.
3. Set the unit (LB or KG).
3. Place the object on the scale. The display will show a value for the object’s weight.
4. Press the ZERO button. The word “TARE” will appear on the display, followed by “0.0” LB or
“0.0” KG.
5. Place additional item (object) on the platform and only the weight of the additional item will be
displayed.
6. When you remove the item from the platform “under” will be temporally displayed and then
the displayed will return to “0.0” LB
19
MAINTENANCE
Maintenance
The following pages provide instructions for maintenance, cleaning, calibration, and
troubleshooting for the 498KL scale. Maintenance operations other than those described in this
manual should be performed by qualified service personnel.
Caution: Before first use, or after long periods of non-use, check the scale for proper
operation and function. If the scale does not operate correctly, refer to qualified service
personnel.
1. Check overall appearance of the total scale for any obvious damage, wear, and tear.
2. Inspect the AC adapter for cord cracking or fraying, or for broken/bent prongs.
Note: This scale is an extremely sensitive weighing device. If the auto-off function is disabled,
battery power will be consumed.
Cleaning
Proper care and cleaning is essential to ensure a long life of accurate and effective operation.
Caution: Disconnect the scale from the AC adapter power source prior to cleaning the
unit.
1. Clean all external surfaces with a clean damp cloth or tissue. Mild antimicrobial or
antibacterial soap and water solution may be used. Dry with a clean soft cloth.
2. Do not immerse the scale into cleaning or other liquid solutions.
3. Do not use Isopropyl Alcohol or other solutions to clean the display surface.
4. Do not use abrasive cleaners.
20
CALIBRATION
Calibration
This scale has been factory calibrated, and does not require calibration prior to use. If
required, the scale can be calibrated. Calibration of your 498KL scale is performed using
kilograms (KG) or pounds (LB), according to the units of measure used upon entering into the
calibration path. The following calibration assumes the scale is set to pounds, and 100 (40 kg) /
200 (80 kg) / 300 (120 kg) / 500 (200 kg) lb is employed as the calibration standards.
Scale Calibration
21
TROUBLESHOOTING
Troubleshooting
Before contacting service personnel, refer to the following instructions to check and to correct
any failures.
22
WARRANTY
Limited Warranty
PELSTAR, LLC
11800 South Austin Avenue • Alsip, IL 60803 • USA
1-800-638-3722 or 1-708-377-0600
PLEASE REGISTER YOUR SCALE FOR WARRANTY COVERAGE AT:
http://www.homscales.com/customers/registration.aspx
Health o meter® is a registered trademark of Sunbeam Products, Inc. used under license.
Health o meter® Professional products are manufactured, designed, and owned by Pelstar, LLC.
We reserve the right to improve, enhance, or modify Health o meter® Professional product features or specifications
without notice.
© Pelstar, LLC 2012
23