200 4550 200 200 4550 200 3. This drawing must be read in conjuction with separate
Architectural drawings.
4. Cover to main reinforcement to be as follows:
(a) Foundation = 50mm. (b) Columns = 40mm.
200
200
01
(c) Beams = 30mm. (d) Slabs = 25mm
4T8-200-03-T2
200
200
5. "Y" Denotes square twisted high yield bars to BS 4461.
600
6. Reinforcement in walls and columns must be inspected before
being enclosed in the formwork.
7. All reinforcement and formwork must be approved by the
01
structural Engineer.
8. All masonary works must be reinforced with hoop iron after
3000
3000
36T10-200-09-B2
4T8-200-01-T2 every alternate course.
600
3000
3000
600 9. Mass/Blinding concrete ~ 1:3:6.
10. Reinforced Concrete (R.C.) ~ 1:1.5:3. {fcu=25N/mm2}
8T8-200-06-T2
18T10-200-07-T1
03
commencing work.
200
200
13. Holding-Down/Anchor Bolts to be cast to 5mm Accuracy and
200
200
should be Re-cast if this Tolerance is Exceeded.
03 Biggest bar.
1950
15. Place TOP BARS on ALL BEAMS even where not indicated
8T8-200-05-T2
7T8-200-02-T2 on drawing. Where lengths of TOP 'T1' BARS are not given
1950
10T10-200-08-T1
use minimum of 600mm .
2950
16. Concreting of steps to be done in layers
600
17. Engineer(s) to Ensure Foundation is Placed on Well
2950
03 03 Compacted Soil, Murram, Hardcore or Hard Rock.
18. All Steel Works to be Wire-Brush Cleaned Prior Application.
19. All Bolts Grade 4.6.
20. All Fillet welds to be >= 6mm Unless Otherwise Stated.
200 1000
7T8-200-04-T2
600
1200
REVISIONS
02
200
Date Description:
200
450
450
02
450
200 1000 1150 200 2200 200
1200 1150 200 2200 200
RING BEAM AND SLAB {150mm Thick} CONSULTANT:
FOUNDATION LAYOUT LAYOUT & DETAILS WESNICK PROJECTS LIMITED,
P.O. BOX, 18258-20100,
NAKURU.
Mob. +254-723-78 38 48
CLIENT:
FRIENDS APARTMENT LIMITED,
P.O. BOX, 2119-20100,
NAKURU.
200
200
200
TO BE DETEMINED ON SITE
450
T8@200
TO BE DETEMINED ON SITE
NAKURU COUNTY.
3T10-02-B2
3T10-02-B2
3T10-200-04-T2
2T12
T10-200-03-B1/T1
200
200
Blinding
TITLE:
200
Blinding
600 Blinding
600
600
TYPICAL 450 X 200 BEAM A
T10-200-01-B1 STRUCTURAL WORKING DRAWINGS.
T10-200-01-B1
3T10-200-02-B2
FOUNDATION, ROOF BEAM AND SLAB {150mm Thick}
SECTION 03-03 (1:30) SECTION 02-02 (1:30) LAYOUT & DETAILS
SECTION 01-01 (1:30)
Designed by: Wambugu Scale ~ 1:30
Sheet 01 of 01