DESCRIPTION UOM For 1 Engine For 4 Engines Make Remarks
1 Generator capacity KW 1117 4468 2 Gas quantity at flue gas duct - wet Am3/min,w 280 NA 3 O2 - Actual Vol %, w 6 4 O2 - Ref Vol %, d 15 5 NOx Base line value dry @ 15%(ref) O2 ppmvd,ref.O2 671 6 Target Nox after SCR- dry @ 15%(ref)O2 ppmvd,ref.O2 201.3 7 Ammonia Slip ppmvd,ref.O2 5 8 Maximum Pressure drop across SCR mbar <15 9 Flue Gas Pressure mbar 1013 10 Temperature at reagent injection point °C 500 Adblue solution Customer 11 Type of reagent used (Urea Soln 32%) Scope 12 Reagent concentration w-% 25 13 Storage Tank Capacity ltr 2000 14 Nominal Reagent consumption Design kg/h 40 160 15 Nozzle Capacity lpm 2 8 16 No. of Nozzle 1 4 ERC Chemtrols 17 Reagent Pump Capacity M3/hr 0.5 @ 6bar KSB /Grundfos/ERC 1 Working + 18 Motor rating for Pump KW 0.5 Chemtrols 1 Stand by 19 Compressed air required Nm3/h 20 80 Customer 20 Compressed air FAD with 10% margin m3/h 29 115 Scope 21 Number of reactor 1 4 ERC Chemtrols 22 Reactor Size W x H x L mm 1000x1000x2700 NA 23 Number of Mixing Duct 1 4 ERC Chemtrol 24 Mixing duct size mm ф600X2650 NA 25 Number of Distribution Module 1 4 26 Catalyst Type Honeycomb IBIDEN /EQ 27 Catalyst Pitch mm 2.5 28 Catalyst Volume Per Reactor m3 1.46 29 Number of catalyst Layer per reactor 3 NA 30 Catalyst size W x H x L mm 312 X 312 X 462 NA 31 NRV for Reagent Pump 2 ERC Chemtrols 32 Pressure Transmitter in pump discharge 1 E&H / WIKA / 33 Pressure Transmitter in air line 1 Honeywell 34 Pressure Transmitter in Reagent line 1 4 35 Pneumatic Control Valve in Reagent Line 1 4 Chemtrols with Rotex 36 Pneumatic Control Valve in Air Line 1 37 Rotameter with Transmitter in Reagent line 1 4 Chemtrols 38 Solenoid valve in Reagent line 1 4 Rotex/Chemtrols 39 Solenoid valve in Air line 1 4 40 Temperature Transmitter 1 4 Tempsens/Chemtrols 41 DP Transmitter across Catalyst 1 4 Honeywell 42 PLC 1 Siemens / EQ