Вы находитесь на странице: 1из 4

PROJECT TITLE: 0536 TAHAP WARISAN DESIGNER JIA HONG

SLAB MARK: TY CANTILEVER SLAB CHECKER


DATE 12/05/2018
CANTILEVER LENGTH 1.600 m
Fcu 25 N/mm2 3
Fy 460 N/mm2
SLAB THK 160 mm 3.84
SDL 1.2 kN/m2 BRICK WALL BRICK WALL
LIVE LOAD 1.5 kN/m2 HEIGHT 0m THICKNESS 0m

ULTIMATE LOAD
FLOOR LOAD BRICK WALL LOAD
= 9.456 kN/m2 = 0 kN/m

ULTIMATE MOMENT = 12.1 kNm/m


129
k = 0.029
125
Z = 123

As req = 247 mm2/m 247


As min = 208 mm2/m
PROVIDE
TOP
T 12 --- 200 566 mm2/m 1
BOT 0.727
T 10 --- 200 393 125 mm2/m 1

M.F (Ten) = 2.35


M.F (Com) = 1.092

M.F = 2
L/d (actual) = 12.4

L/d (allow) = 14 DEFLECTION OK


PROJECT TITLE: DESIGNER How
SLAB MARK: CANTILEVER SLAB CHECKER
DATE 12/05/2018
CANTILEVER LENGTH 1.600 m
Fcu 25 N/mm2
Fy 460 N/mm2
SLAB THK 125 mm
SDL 1.2 kN/m2 BRICK WALL BRICK WALL
LIVE LOAD 1.5 kN/m2 HEIGHT 0m THICKNESS 0m
Slab dead load 3 kN/m2
Water tank load 0 kN/m2
ULTIMATE LOAD
DESIGN LOAD BRICK WALL LOAD
= 8.28 kN/m2 = 0 kN/m

ULTIMATE MOMENT = 10.6 kNm/m


d = 94 mm
k = 0.047978271
z = 88.68884743 mm
Z = 88.68884743 mm

As req = 273 mm2/m 273


As min = 162.5 mm2/m
PROVIDE
TOP
T 12 --- 200 566 mm2/m 1 M/bd^2 = 1.199
BOT fs = 148.3
T 12 --- 200 566 139 mm2/m 1
Modification Factor (Tension reinforcement)

Mf = 0.55+ + ((477 - fs)/(120(0.9 + M/bd^2) < 2.0

s,req)/(3*As,prov) = 148

M.f 1.855 > 2 Less than 2.0 as per code, PASS!

Modification Factor (Compresion reinforcement)

Mf = 1+(100As'prov/bd)(3+100As'prov/bd) <1.5
100As'prov/bd = 0.602
Mf = 1.167 < 1.5 Less than 1.5 as per code, PASS!

M.F = 1.854789

L/d (actual) = 17.02128


L/d (allow) = 12.98352 DEFLECTION FAIL

Вам также может понравиться