Вы находитесь на странице: 1из 341

BERGEN-POWER PIPE SUPPORTS, INC.

A wholly owned subsidiary of The Paterson Group, Inc.

PIPE SUPPORTS
FOR
NUCLEAR
CONSTRUCTION

CATALOG NF09.
• Certified Design Report Summaries
• Load Capacity Data Sheets
• Product Information Sheets
• Ordering Instructions

DRAFT COPY FOR REFERENCE ONLY


Quality Standard Supports Meeting ASME Section III Subsection NF Requirements.
CATALOG 09.5NF - INDEX SHEET

Part Number Rev. Description


1000 0 Restraint End Connection
1001 0 Restraint End Attachment
1003 0 Snubber Bracket and Pin
1047 0 Welded Beam Attachment
1052 2 Welding Lug
1200 0 Washer Plate
2015 0 Rigid Rod Strut
2250 0 Adjustable Rigid Strut
2252 0 Field Adjustable Rigid Strut
2420 1 Short Strut Assembly with MSA by PSC (Size 0.35 to 15)
2421 0 Short Strut Assembly with MSA by PSC (Size 50 and 120)
2440 3 Strut Assembly with PSC MSA
2825-4" 0 Short STC Hydraulic Snubber Assembly (2 to 60 kips)
2825-6" 0 Short STC Hydraulic Snubber Assembly (2 to 60 kips)
2825-10" 0 Short STC Hydraulic Snubber Assembly (2 to 60 kips)
2826-4" 0 Short STC Hydraulic Snubber Assembly (100 to 250 kips)
2826-6" 0 Short STC Hydraulic Snubber Assembly (100 to 250 kips)
2826-10" 0 Short STC Hydraulic Snubber Assembly (100 to 250 kips)
2830-4" 0 Standard STC Hydraulic Snubber Assembly (2 to 60 kips)
2830-6" 0 Standard STC Hydraulic Snubber Assembly (2 to 60 kips)
5

REV 2830-10" 0 Standard STC Hydraulic Snubber Assembly (2 to 60 kips)


2831-4" 0 Standard STC Snubber Assembly (100 to 250 kips)
2831-6" 0 Standard STC Snubber Assembly (100 to 250 kips)
2831 10"
2831-10" 0 Standard STC Snubber Assembly (100 to 250 kips)
2860-4" 0 Short STC Mechanical Snubber Assembly
2860-6" 0 Short STC Mechanical Snubber Assembly
2860-10" 0 Short STC Mechanical Snubber Assembly
2870-4" 0 Standard STC Mechanical Snubber Assembly
2870-6" 0 Standard STC Mechanical Snubber Assembly
2870-10" 0 Standard STC Mechanical Snubber Assembly
3100 1 Variable Support Hanger
3100 Type GB 0 Variable Support Hanger
3200 1 Variable Support Hanger

End of Index Page


2

REV

BERGEN-POWER PIPE SUPPORTS, INC. Sheet 1 of 4


TRANSMITTAL INDEX SHEET DATE:
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
CATALOG 09.5NF - INDEX SHEET

Part Number Rev. Description

3200 Type GB 0 Variable Support Hanger


3201 0 Variable Support Hanger
3400 1 Variable Support Hanger

3400 Type GB 0 Variable Support Hanger


3401 0 Variable Support Hanger
4000 SHT. 1 0 Constant Support
4000 SHT. 2 1 Constant Support
4000 SHT. 3 2 Constant Support
4000 SHT. 4 2 Constant Support
4000 SHT. 5 2 Constant Support
4000 SHT. 6 1 Constant Support
4000 SHT. 7 N/A Not Used
4000 SHT. 8 N/A Not Used
4000 SHT. 9 0 Constant Support
4000 SHT. 10 0 Constant Support
4004 2 TC-4 Connection
4007 2 TC-7 Connection
4100 SHT. 1 1 Constant Support
5

REV 4100 SHT. 2 2 Constant Support


4100 SHT. 3 2 Constant Support
4100 SHT. 4 2 Constant Support
4100 SHT
SHT. 5 1 Constant Support
4100 SHT. 6 NA Not Used
4100 SHT. 7 NA Not Used
4100 SHT. 8 0 Constant Support
4100 SHT. 9 0 Constant Support
5000 0 Machine Thread Rod
5006 0 All Thread Rod
5100 0 Forged Steel Turnbuckle
5110 0 Forged Steel Clevis
5130 0 Forged Steel Weldless Eye Nut-RH
5131 0 Forged Steel Weldless Eye Nut-LH
6015 SHT. 1 0 Friction Type Anchor
6015 SHT. 2 0 Friction Type Anchor
6015 SHT. 3 0 Friction Type Anchor
6100 0 Two Bolt Pipe Clamp

End of Index Page


2

REV

BERGEN-POWER PIPE SUPPORTS, INC. Sheet 2 of 4


CATALOG INDEX SHEET DATE:
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
CATALOG 09.5NF - INDEX SHEET

Part Number Rev. Description


6101 0 Heavy Two Bolt Pipe Clamp
6140 3 Pipe Saddle
6150 0 Three Bolt Pipe Clamp
6152 0 Heavy Three Bolt Pipe Clamp
6175-0.7 0 Yoke Type Restraint Pipe Clamp
6175-1.5 0 Yoke Type Restraint Pipe Clamp
6175-4 0 Yoke Type Restraint Pipe Clamp
6175-7 0 Yoke Type Restraint Pipe Clamp
6175-12 0 Yoke Type Restraint Pipe Clamp
6175-25 0 Yoke Type Restraint Pipe Clamp
6175-35 0 Yoke Type Restraint Pipe Clamp
6175-60 0 Yoke Type Restraint Pipe Clamp
6175-80 0 Yoke Type Restraint Pipe Clamp
6175-130 0 Yoke Type Restraint Pipe Clamp
6202-.35 0 Pipe Clamp for Strut Assemblies
6202-.65 0 Pipe Clamp for Strut Assemblies
6202-0.7 0 Pipe Clamp for Strut Assemblies
6202-1.5 0 Pipe Clamp for Strut Assemblies
6202-4 0 Pipe Clamp for Strut Assemblies
6202-6 0 Pipe Clamp for Strut Assemblies
5

REV 6202-7 0 Pipe Clamp for Strut Assemblies


6202-12 0 Pipe Clamp for Strut Assemblies
6202-15 0 Pipe Clamp for Strut Assemblies
6202 25
6202-25 0 Pipe Clamp for Strut Assemblies
6202-35 0 Pipe Clamp for Strut Assemblies
6202-50 0 Pipe Clamp for Strut Assemblies
6202-60 0 Pipe Clamp for Strut Assemblies
6202-80 0 Pipe Clamp for Strut Assemblies
6202-120 0 Pipe Clamp for Strut Assemblies
6202-130 0 Pipe Clamp for Strut Assemblies
6202-200 0 Pipe Clamp for Strut Assemblies
6242 0 Pipe Strap
6243 0 Pipe Strap
6252-.35 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-.65 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-0.7 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-1.5 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-4 0 Off-Axis Pipe Clamp for Strut Assemblies

End of Index Page


2

REV

BERGEN-POWER PIPE SUPPORTS, INC. Sheet 3 of 4


CATALOG INDEX SHEET DATE:
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
CATALOG 09.4NF - INDEX SHEET

Part Number Rev. Description


6252-6 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-7 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-12 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-15 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-25 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-35 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-50 0 Off-Axis Pipe Clamp for Strut Assemblies
6252-60 0 Off Axis Pipe Clamp for Strut Assemblies
6280-0.7 0 Restraint Riser Clamp
6280-1.5 0 Restraint Riser Clamp
6280-4 0 Restraint Riser Clamp
6280-7 0 Restraint Riser Clamp
6280-12 0 Restraint Riser Clamp
6280-25 0 Restraint Riser Clamp
6280-35 0 Restraint Riser Clamp
6280-60 0 Restraint Riser Clamp
6300-0.73 0 Riser Clamp
6300-1.35 0 Riser Clamp
6300-3.23 0 Riser Clamp
6363 0 Straight Pin & Cotter Pins
5

REV 6439 0 Bolted Pipe Strap


6440 0 Pipe Strap
6441 0 Pipe Strap
6500 SHT
SHT. 1 0 Long Tangent U U-Bolt
Bolt
6500 SHT. 2 0 Long Tangent U-Bolt
6502 SHT. 1 0 Long Tangent U-Bolt
6502 SHT. 2 0 Long Tangent U-Bolt
6504 SHT. 1 1 Variable Tangent U-Bolt
6504 SHT. 2 0 Variable Tangent U-Bolt
6525-0.7 1 U-Bolt Restraint Clamp
6525-1.5 1 U-Bolt Restraint Clamp
6526-0.7 1 U-Bolt Restraint Clamp
6526-1.5 1 U-Bolt Restraint Clamp
8460 0 U-Bolt Slide Guide
8520 0 Clamp Slide
8560 0 Clamp Slide
8820 0 Plate with Graphite Slide (Welded)
8821 0 Pre-Insulated Slide w/ No Strap
8822 0 Pre-Insulated Slide w/ Strap
8823 0 Pre-Insulated Slide w/ U-Bolt
8827 Pre-Insulated U-Bolt Guide Assy.
8828 Pre-Insulated Strap Guide Assy.
8840 0 Plate with Graphite Slide (Bolted)
8860 0 Graphite Guide Base (Welded)
End of Index Page
2

REV

BERGEN-POWER PIPE SUPPORTS, INC. Sheet 4 of 4


CATALOG INDEX SHEET DATE:
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tit r, N
CERTIFIED DESIGN REPORT SUMI'JIARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
-
RESTRA'A'T END ATTACHMENT . PART NUMBER |OOO

SIZES .7 THROUGH 4 SIZES 7 THROUGH 2OO

<-__-_____>
FORCE

._ J ._
FORCE --1 FORCE
1g"J

Temperature: 3500F

no"t
,0r' the test condition (Hydro)the maximum temperature is 1000F, For higher
Design Spec. No. D91000
temperatures in the Test Condition, use Level B loads up to the temperature
Design Repoft No. DR-1000
shown for the Operating Condition.

Kip Operating Conditions Test Condition


Design Condition
Size Level A Level B Level C Level D {see Note)
0.7 700 700 931 1,050 1,315 931

1.5 1,500 1,500 1,995 2,250 2,819 1,995


4 4,000 4,000 5,320 6.000 7,516 5,320
7 7,000 7.000 9,310 10:500 13,153 9,310
12 12,000 12,000 15,960 18,000 22,il8 15,960
25 25,000 25,000 33,250 37,500 46,975 33,250
35 35,000 35,000 46,550 52,500 65,765 46,550
60 60,000 60,000 79,800 90,000 112,740 79,800
80 90,000 80,000 106,400 120,000 150,320 106,400

130 130,000 130,000 172,900 195,000 244,270 172,900


200 200,000 200,000 266,000 300,000 375,800 266,000
-oads (lbs)
//bsl for Classes 1.2,3 & MC
I certify this CDRS complies with be CONTROLREFNO. 1()(l(}
rcquirements of the applicaHe ode MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36, A108 Gr 1018 CW (CC N-71)
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: SA 564 TYP 630
Bergen Power Pipe Supporfs, lnc.
Studs: N/A
Product Engineering DePaftment
ilemptCotter pins, Washers, Retainers (NF-21 21)
REVISIONS
/^
4,{'>/.d'fr /o\ Oriqinal lssue 10/27109
/r\ /^
SEAL | /a/r7/a? lslGNED /\ /J

BERGEru POWER PIPE SUPPORIS, INC, SHEET 1 OF r REV.


A PART NO. l(l(}(l
CDRS CATALOG INFORMATION SHEET

RESTRA''VI END ATTACHMENT


. PART NUMBER |OOO

SIZE 7 THROUGH 2OO

SIZE .7 THROUGH 4

__J
*lT

l. *---J

KIP SIZE E tt L N P R T W K*
3/8 7t8 1t2 1112 1.0
0.7 17t8 1t2 1118 9/1 6

1.5 2114 5/8 1112 3t4 11t2 1 1t8 1t2 13t4 2.5

11t2 3t4 11t2 1118 1t2 1314 2.5


4 21t4 5/8
7 27t8 7t8 3112 1112 3t4 1 118 314 31t4 3.0

12 27lB 7t8 3112 11t2 3t4 11t8 314 31t4 3.0

1 3/8 5 21t8 1 15t8 1 4114 3.0


25 3718
35 4114 1 112 5 314 23t8 11t4 17 t8 1114 5 3.0

111116 71t4 3 11t2 23t8 1112 6 6.6


60 5 5/8
113118 9114 3 5/8 13t4 25t8 1314 7 314 7.2
80 6114
130 8112 2 111 11 5/8 4 518 21t2 3 3/8 13t4 8718 8.0

10 3t4 2 5/16 15 5114 3 4118 23t4 111t2 nla


200

*xloE lb/in.

NOTES:
1.) All dimensions are in inches'
2.) Dimbnsions are provided for user application only'
plate'
3,) Spring rate (K) is for loads applied perpendicular to the base
4.)This assembly is to be use with BPPS parts 2015, 2250,2252,2525,2530,2420,2421&2440'

ORDERING INSTRUCTIONS:
Designation.
Specify: part Number, CDRS Revision Number, and Kip Size

DGMPLE: 1000-R/0-60

lssue 10/27109

PART NO. lO(lO


BERGEN POWER PIPE SUPPORTS' INC,
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

RESIRII'fVT END ATTACHMENT . PART NUMBER 1OO1

SIZES .65 THROUGH 6 SIZES15 THROUGH 120

1 80" <----)> .+
FORCE FORCE

<___-__--__>
J H-
FORCE
-l
1oo--J
FORCE

Temperature: 3500F

Nott'
the test condition (Hydro)the maximum temperature is 1000F. For higher
Fo1.
Desion Soec. No. DS-1000
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-1000
shown for the Operating Condition'

Kip Operating Conditions Test Condition


Design Gondition Level D {see Note}
Size Level A Level B Level C
0.65 650 650 865 975 1,221 865

1.s 1,500 1,500 1,995 2,250 2,819 1,995

6 6,000 6,000 7,980 9,000 11,274 7,980


15 15,000 15,000 19,950 22,500 2E,185 19,950

50 50,000 50,000 66,500 75,000 93,950 66,500


120 120,000 120,000 159,600 180,000 225,480 159,600

Rated Loads (lhs) for Classes 1,2,3 &MC

NO.
I certily this CDRS comdies wilh he
rcquirements of the applicable code
The Design Report & Design Specification are in
ffir1o18cw(ccN-71 accordance with ASME BPVC Section lll, Subsection
NF 2007 Edition and are on file at:

Bergen Power PiPe SuPPods' lnc.


Product Engineering DePartment
ffiRetainers(NF-2121
REVISIONS

BERGEN POWERPIPE SUPPORTS, INC,


CDRS CATALOG INFORMATION SHEET

RESIRII'TIJT END ATTACHMENT - PART NUMBER 1AO1

SIZE 15 THROUGH 120

SIZE.65 THROUGH 6

R-r
\-
I
I

L-*--l

KIP SIZE E t.' L N P R T W

0.65 1 3/8 0.42 1 1t2 3t8 7t8 3/8 1114


1.5 1314 0.52 11t2 3t4 1t2 1118 1t2 1112

6 2114 0.77 2114 1118 3t4 11t2 5/8 2114


15 3718 1.01 5 21t8 1 1 3/8 1 4114
50 5 5/8 1.70 7 114 3 11t2 2318 1112 6

120 8112 2.07 115t8 4 5t8 21t2 3 3/8 1314 8718

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only'
replacement rear brackets for
3.) For use with pacific scientific company manufactured struts and as
BPPS Parls 2420,2421, and 2444'

ORDERING INSTRUCTIONS:
specify: Part Number, CDRS Revision Number, and Kip size Designation'

DGMPLE: 1001-R/0-50

lssue 10/27109

BERGEN POWER PIPE SUPPORTS, INC.


CDRS CATALOG INFORMATION SHEET

SfVUBBER BRACKET and PIN - PART NUHBER 1003

r'l

,,,,,*nllhlllil,u" q"nn,p
KIP SIZE L P R T w
*{lll#ll,} 718 1112 112 u4 5/10 11t2
!{iin*. 1 3/4
.'i11
.r4$P3 2 3/14"'- 1 21t8 9/16 I 9/16 2
Ir' $dl, ulInk#il 1 5/16 2 9t16 11t16 11t4 5/8 2 7t16
Iti,dfilt "r5'1/4 I 3/8 31t4 1 1ffi 7t8 3

't{ "||ll*$ ..af


t" 3718 1ffi 37t8 1 3/16 17t8 1 1/10 3ffi
illtu' 1 13/3 43t8
{ullilfl" 4 9/16 1 7t8 411t16 9/16 2114
'll}lu" .url nxr$lF0 6718 2 3t4 61t4 2 3 1 9/16 5 11/16

-$ffiffi
1.)Alldimensions are in inches.
2.) Dimensions ire provided for user application only.
3.) This assembly is to be use wiilt B'P Parts 2825 and 2830.

ORDERING INSIRUCTIOI{S:
Specfy: Part Number, CDRS Revision Number, and Kip Size Designation.

$fiMPLE: 1003'R/0-60

BERGEN',POWERHPE SUPPORT$ r tc.


( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tiE,
d*
dY
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

WELDED BEAM ATTACHMENT . PART NUMBER 1047

TYPE 1 TYPE 2

__i ri_

DIRECTION OF LOADING

Temperature: 3500F

N*t'
Fol, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D91047
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-1047
shown for the Operating Condition.

0perating Conditions Test Condition


Size Design Gondition (see Note)
Level A Level B Level C Level D
3/8 730 730 971 1,095 1,153 971
1t2 1,350 1,350 1,796 2,025 2,133 1,796

5'8 2,160 2,160 2,873 3,240 3,413 2,873


3t4 3,230 3,230 4,296 4,845 5,103 4,296
1 5,900 5,900 7,847 8,850 9,322 7,847
- 12,635
11t4 9,500 9,500 12,635 14,250 15,010
11t2 13,800 13,800 18,354 20,700 21,804 19,354

1314 18,600 18,600 24,738 27,900 29,388 24,738


2 24,600 24,600 32,718 36,900 38,868 32,718
21ll4 32,300 32,300 42,959 48,450 51,034 42,959
21n 39,800 39,800 52,934 59,700 62,884 52,934
Rated Loads ilbd for Classes 1,2,3 & MC
CONTROL REF NO. 1047
lcertify this CDRS complies with he
rcquircments of the aPPlicabh code MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: SA-193 Gr 87
Bergen Power PlPe SuPPorts,lnc,
Studs: N/A
Product Engineering DePartment
E-xemtt-otter pins, Was hers, Reta i n ers (N F-2 1?])
REV|StONS
/d, Oriqinal lssue 1 0/27109 /J
4-4;,.-/.M*G, /1' /t
lpfr*f lslcNED
s'Ear /) /i
BERGEN POWER PIPE SUPPORTS, INC, SHEET 1 0F I REv. a PARTNO. 1047
CDRS CATALOG INFORMATION SHEET

WELDED BEAM ATTACHMENT


. PART NUfrIIBER 1047

TYPE 2

-J-J--

r:= t_
rt-Yt P
J+-+L f--
c -*1 I
w --*l

--l oL
E G H P T w
ROD SIZE E1

1718 1114 2718 1t2 1t4 2


3'8 2
13t4 1 1t4 27t8 5/8 114 2
112 2
27t8 3t4 114 2
5/8 2 13t4 1114
1314 1112 3 1/8 7t8 3/8 2112
314 2

1 3 2314 2 4112 11t8 1t2 3

27lB 2112 5 1 3/8 5/8 4


11//4 3
4 3 6112 1518 3t4 5
11//2 4
E
1314 5 5 33t4 7 314 17t8 314

2 5 5114 3314 8114 21t4 314 6

21|4 6 6114 41t4 9112 21t2 3t4 6

41t2 I314 2314 314 6


2112 6 6114

NOTES:
L)All dimensions are in inches'
2) Dimensions are provided for user application only'

ORDERING INSTRUCTIONS:
Specify: part Number, CDRS Revision Number, and Rod Size and Type

EXAMPLE: 1047-R/0-3/4"-Type 1 (or) 2

inallssue 10127109

PART NO. 1047


AENOEN POWER PIPE SUPPORTS'
'NC'
LOAD CAPACITY DATA SHEET
for
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS
WELDING LUG

o DIRECTION
OF
LOADING

oF
DESIGNED BY: Load ratinq TEMPERATURE: 350
LOAD RATTNG (LBS)
for Class 1,2,3 & MC
OPERATING CONDMONS
DESIGN
srzE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
a NORMAL UPSET EMERGENCY FAULTED CONDITION
EIIJ> 3/8 610 610 810 915 1220 810
1/2 1 130 1 130 500
1 1 695 2260 1500
5/8 1810 1810 2400 2715 3620 2400
314 2710 2710 3600 4065 5420 3600
1 4960 4960 6600 7440 9920 6600
1 1t4 8000 8000 1 0600 12000 1 6000 1 0600

1 1t2 11630 11630 1 5500 17445 23260 1 5500

13t4 1 5700 1 5700 20900 23550 31 400 20900


2 20700 20700 27600 31 050 41400 27600
JI
ol 21/4 27200 27200 36200 40800 54400 36200
<l FD
FI o 2 112 33500 33500 44600 50250 67000 44600
ol
<l t2
2 314 580 580 55400 62370 831 60 55400
ol t 41 41
JI o 67400 75870 101160 67400
url 3 50580 50580
t2 I tr 80600
>I ltl 3114 60480 60480 80600 90720 1 20960
url
EI 31t2 71280 71280 95000 1 06920 142560 95000
ol
z1 ==J
<l 3 314 82890 82890 1 1 0500 124335 1 65780 1 1 0500
al
<l ul
UJ
4 95400 95400 127200 1 431 00 1 90800 127204
(,
>l z
rJ,t I

ul
clI C)
ol
()I g
urI tr
FI
<t o NOI E: I cenify that this LUUU comphes
Materials: Stress calculations or test data for this Droduct werc
al
o-I I with the requirements of the applicable

4fl 4
code. Plate: SA-36 perlormed ln accordance with: ASME BPVC
CENTII"IN III CIINCEI1TI..IN NFNNMDT1NFNT
N .<
2007 Edltlon and are on file at:
EIIJ> fiueeOnTs
BEBGEN.POWEB PIPE SUPPORTS, INL.
J Product Engineering Department

Cotter Pins, Washers, Retainers Exempt ( NF-2121) NO. 1052


FilF BERGEN-aIwER ptpE suppo+Ts, tvc.
sONTROLREF.

o nlS LoAD cAPActw DATA sHEET


Sheet
j!_of 1
REV
A
PART NO.
1 052

-EI
BY
CUSTOAAER

ROD R
E H T w
SIZE
3/8 112 9/1 6 1 114 1/4 2 1t2
1/2 1 112 11/16 1 1t4 114 2 112
518 1 1/2 13/16 1 1/4 1/4 2 112
3/4 1 3t4 15/16 1114 3/8 2 1t2
1 2114 1 114 1 1t2 1/2 3
1 114 3 1 1t2 2 5/8 4
1 112 31t4 1314 2 1/2 3/4 5
1 3/4 3 1t4 2 2 1/2 314 5
2 4 2 3/8 3 3/4 6
21/4 4 114 2 5/8 3 314 6
2 112 4112 27t8 4 1 8
2 314 5 31t8 4 1 8
3 5 3 3/8 4 1 114 8
3 1t4 5 3 5/8 41t2 1114 I
3112 6 3 7/8 41t2 1 112 I
3 3t4 6 41t8 41/2 1 314 9
4 6 4 3t8 5 1 3/4 10

NorES:
I 3',',1$3[1,"-l],1""11.lilii", "=", """,,"",,"" "",".
ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 1052-Rl2- 314"

IETS BERGEN.POWER PIPE SUPPORTS INC. PART 1052

ru
HJ
CATALOG INFORMATION SHEET DATE 3/3/e3
tit ],
rul
E
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

WASHER P4I/.TE. PART NUMBER 12OO

O
I

DIRECTION OF LOADING

Temperature: 3500F

Nott'
For, the test condition (Hydro)the maximum temperature is 1000F, For higher
Design Spec. No. DS-1200
temperatures in the Test Condition, use Level B loads up to the temperature
Design Repoil No. DR-1200
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
318 730 730 971 1,095 1,372 971
112 1,350 1,350 1,796 2,025 2,537 1,796
518 2,160 2.160 2,873 3,240 4,059 2,873
3t4 3,230 3,230 4,296 4,845 6,069 4,296
1 5,900 5,900 7,847 8,850 11,086 7,847
11ll4 9,500 9,500 12,635 14,250 17,851 12,635
1112 13,800 13,800 18,354 20,700 25,930 18,354
13|,4 18,600 18,600 24,738 27.900 34,949 24,738
2 24,600 24,600 32,718 36,900 46,223 32,718
2114 32,300 32,300 42,959 48,450 60,692 42,959
21//2 39,800 39,800 52.934 59.700 74,784 52,934
Rated Loads /lbs) for ,2,

I certify lhis CDRS comdies with lhe CONTROLREFNO. 12(l(l


requirements of lhe applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Bergen Power Pipe Supports,lnc,
Studs: N/A
Product Engineering DePailment
Exempt N/A
REVISIONS
/o\ Orioinal lssue 1 0/27109 /s\
/'d"fr /i /l
s(AL lp/n/a' lslGNED /^ /J

BERGEN POWER PIPE SUPPORTS, NC, sHEEr 1 OF 1 REV.


A PART NO. 12OO
trl I,
JI-..
FJ
CDRS CATALOG INFORMATION SHEET

-
WASHER PLATE - PART NUMBER 12OO

-@-
I

L __-]

tt H
ROD SIZE L&W T
GAP HOLE
3/8 11t2 7t16 3 1t4
1t2 11t2 9/16 3 1t4
5/8 1112 11t16 3 3/8
314 2 13t16 4 3/8
1 21t2 1 1/1 6 4 1t2
11/,4 3 1 3/8 5 1t2
11t2 31t2 1 5/8 5 5/8
1314 31t2 1718 5 5/8
2 4 21t8 5 314

211,4 4 23t8 6 314

2112 4112 2518 6 3t4

NOTES:
. L)Alldimensions are in inches'
2.) Dimensions are provided for user application only.

ORDERING INSTRUCTIONS:
specify: Part Number, Revision Number, and Rod size Designation.

EXAMPLE: 1200-R/0-3/8"

REVISIONS
/) Oriqinal lssue 10/27109 /t\
/1' /i
A /i
BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV.
A PART NO. 12OO
titJ, r*
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

RIGID RAD STRUI . PART NUMBER 2015

,A \)
Y Ir ilil Itl
(z

DIRECTIOI{ OF DnECnoil 0F
LOADING LOADIiIG

10' .,e ...--------------

Temperature: 3500F

Nott'
Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D92010
temperatures in the Test Condition, use Level B loads up to fie temperature
Design Report No. DR-2015
shown for the Operating Condition.

Strut OperatinE Conditions Test Condition


Size Design Condition
Lensth * Level A Level B Level G Level D (see Note)
0.7 2',-gu 700 700 931 1,050 1,315 931
1.5 2'-9" 1,500 1,500 1,995 2,250 2,819 1,995
4 3'-0u 4,000 4,000 5,320 6.000 7,516 5,320
Rated Loads (lbs) for Classes 1,2,3 &MC

* <
Maximum strut length (without adjustment)for rated loads shown with transverse acceleration 1G.

I certify this CDRS mmflies with $e CONTROLREFNO. 2015


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36, A108 Gr 1018 CW (CC N-71)
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe Supporfg /nc.
Rod: 5A-36
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers, (NF-2121)
REVtSt0NS
/d, Oriqinal lssue 1 0/27109 )
E--bK'4'.e /i
l/
SEAL ln/zz/ai lslGNED /i It i
BERGEA' POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REV.
A PART NO. 2015
lit r, b
d
CDRS CATALOG INFORMATION SHEET

RIGID ROD STRUT . PART NUMBER 2015

Strut Length (P-P)

irlr --a-- +-l-


rrlt
IL_V_
-e
_!-
rlrt
-l-: t

--.1- l

Swing Rad.

KIP P.P a X
A B D E L P R s T W
+l-314
srzE MIN MAX FT.LBS
0.7 3t4 1t2 7t16 1718 1 118 3/8 10314 33 15 1 1 1t2 1t2 11t2 23t4
1.5 314 5/8 1t2 21t4 11t2 1t2 10 3t4 33 15 11t8 11t2 1t2 13t4 23t4
4 1 5/8 1t2 21t4 11t2 112 131t4 36 35 11t4 13t4 1t2 13t4 3 5/8

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only,
3.) P-P dimensions given allow for a +l'1-112'adjustment.
. 4.) Set adjustment at the desired P-p and tighten the nuts to the nominal torque value (Q) as specified in the table above
. 5.)This strut is compatible with B-P Parts 6175,6202,6252,6280, 6525 and 6526.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length,

EMMPLE: 2015-R/0-4k P-P = 24"

REVISIONS
i0\ Oriqinal lssue 10/27109 /z\

A /+\
/^ /5'

BERGEN PAWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REV.


A PARTNO. 2015
CERTIFIED DESIGN REPORT SUMMARY
tiJ J, ,d
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
-
ADJUSTABLE RIGID STRUT . PART NUMBER 2250

(t 2" Adjustment)

DIRECTION DIREGTION
OF OF
LOADING LOADING

...H> .+

Temperature: 3500F

Design Spec. No. DS-2100


For the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Report No. DR-2250
temperatures in the Test Condition, use Level B loads up to the temperature
shown for the Operating Condition.

Strut Operating Conditions Test Condition


Size * Design Condition (see Note)
Length Level A Level B Level C Level D
0.7 9'-4n 700 700 931 1,050 1,315 931

1.5 9'-4n 1,500 1,500 1,995 2,250 2,819 1,995


4 10'-0' 4,000 4,000 5,320 6,000 7,516 5,320
7 10'-0" 7,000 7,000 9,310 10,500 13,153 9,310
12 10'-0" 12,000 12,000 15,960 18,000 22,548 15,960
25 10'-0n 25,000 25,000 33,250 37,500 46,975 33,250
35 10'-0' 35,000 35,000 46,550 52,500 65,765 46,550
60 10'-0' 60,000 60,000 79,800 90,000 112,740 79,800
80 10'-0n 90,000 80,000 106,400 120,000 150,320 106,400
130 10'-0* 130,000 130,000 172,900 195,000 244,270 172,904
200 10'-0' 200,000 200,000 266,000 300,000 375,800 266,000
Rated Loads (lbs) for Classes 1,2,3 & ML

*
Maximum strut length with adjustment, for rated loads shown,

I certify this CDRS complies with the CONTROL REF NO. 2250
requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36, SA515 Gr 70
accordance with ASME BPVC Section lll, Subsection
Rod: 5A-36, 4108 Gr 1018 (CC N-71)
NF 2007 Edition and are on file at:
Nuts: 54-563 Gr A
Pin: S4-564 TYP 630
Bergen Power Pipe SuPPods, lnc.
Pipe: 54-106 Gr B, SA-53 Gr B
Product En gineerin g DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISIONS
/o\ Oriqinal lssue 10/27109 /i
b*fr,&ffi
pa/27/af
/r' 4\
/s\
SEAL ISIGNED /z\

BERGE J POWER PIPE SUPPORTS, lNC. SHEET 1oF 1 | nev. /o\ I PART No. 2250
CDRS CATALOG INFORMATION SHEET

ADJUSTABLE RIGID STRUT - PART NUMBER 2250

By P-P (± 2" Adjustment)


Customer P
(Typ.)

Q
Torque Size 0.7 through 12 R
D (Typ.) Swing
Pipe (Nominal Dia.) Rad.

A
C

Size 25 through 200


S
E
Part 1000 T

B 10°
U

KIP P-P
A B C D E PIPE Q R S T U
SIZE MIN MAX
0.7 1 1/8 1 1/2 9/16 1/2 1 7/8 20 112 1 1/2 S/40 15 1 1 1/2 1/2 7/16
1.5 1 1/2 1 3/4 3/4 1/2 2 1/4 20 112 1 1/2 S/40 25 1 1/8 1 3/8 5/8 1/2
4 1 1/2 1 3/4 3/4 1/2 2 1/4 26 120 2 S/80 50 1 1/4 1 9/16 5/8 1/2
*7 3 1/2 3 1/4 1 1/2 3/4 2 7/8 26 120 2 1/2 S/80 100 2 1 3/16 7/8 5/8
* 12 3 1/2 3 1/4 1 1/2 3/4 2 7/8 26 120 2 1/2 S/80 100 2 1 3/16 7/8 5/8
25 5 4 1/4 2 1/8 1 3 7/8 28 120 3 S/80 100 2 5/8 3 1 3/8 1
35 5 3/4 5 2 3/8 1 1/4 4 1/4 32 120 3 1/2 S/80 100 2 5/8 3 1/2 1 1/2 1 1/4
60 7 1/4 6 3 1 1/2 5 5/8 34 120 5 S/80 100 3 5/8 3 1/2 1 11/16 1 1/4
80 9 1/4 7 3/4 3 5/8 1 3/4 6 1/4 38 120 6 S/80 100 4 1/8 4 1 13/16 1 1/2
130 11 5/8 8 7/8 4 5/8 1 3/4 8 1/2 44 120 8 S/80 100 6 5 1/4 2 1/16 1 1/2
200 15 11 1/2 5 1/4 2 3/4 10 3/4 56 120 8 S/160 100 7 1/8 6 1/4 2 5/16 2

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) P-P dimensions given allow for a + 2 " adjustment.
4.) Set strut at desired P-P and tighted nut to the nominal torque value (Q) for locking.
5.) This strut is compatible with B-P Parts 6175, 6202, 6252, 6280, 6525, and 6526.
* 6.) The 7/12 kip strut use the welded type end attachment.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length.

EXAMPLE: 2250-R/0-4k P-P = 30"

REVISIONS
0 Original Issue 10/27/09 3

1 .7k "C", 7k "B", Added Note #6 8/3/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 0.7 (700 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 114 100 80 60 40 18
3/4 3.50E+05 1.42E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.52E+04
1 3.68E+05 1.42E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 1.52E+04
1 1/4 3.18E+05 1.41E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.51E+04
1 1/2 3.33E+05 1.42E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04 1.51E+04
2 2.92E+05 1.41E+04 1.42E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04
2 1/2 2.33E+05 1.39E+04 1.40E+04 1.42E+04 1.44E+04 1.46E+04 1.48E+04
3 2.50E+05 1.40E+04 1.41E+04 1.43E+04 1.45E+04 1.47E+04 1.49E+04
4 1.84E+05 1.37E+04 1.38E+04 1.40E+04 1.42E+04 1.44E+04 1.46E+04
5 1.63E+05 1.36E+04 1.37E+04 1.39E+04 1.40E+04 1.42E+04 1.44E+04
6 1.35E+05 1.33E+04 1.35E+04 1.36E+04 1.38E+04 1.40E+04 1.42E+04
8 1.21E+05 1.32E+04 1.33E+04 1.35E+04 1.36E+04 1.38E+04 1.40E+04
10 1.25E+05 1.32E+04 1.33E+04 1.35E+04 1.37E+04 1.39E+04 1.41E+04

Size 1.5 (1,500 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 114 100 80 60 40 18
3/4 9.38E+05 1.86E+04 1.88E+04 1.92E+04 1.95E+04 1.99E+04 2.03E+04
1 7.14E+05 1.85E+04 1.87E+04 1.91E+04 1.94E+04 1.98E+04 2.02E+04
1 1/4 5.77E+05 1.84E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 2.00E+04
1 1/2 6.00E+05 1.84E+04 1.86E+04 1.90E+04 1.93E+04 1.97E+04 2.01E+04
2 6.25E+05 1.84E+04 1.87E+04 1.90E+04 1.93E+04 1.97E+04 2.01E+04
2 1/2 5.56E+05 1.84E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 2.00E+04
3 5.00E+05 1.83E+04 1.85E+04 1.88E+04 1.92E+04 1.95E+04 1.99E+04
4 4.17E+05 1.82E+04 1.84E+04 1.87E+04 1.90E+04 1.94E+04 1.98E+04
5 5.00E+05 1.83E+04 1.85E+04 1.88E+04 1.92E+04 1.95E+04 1.99E+04
6 3.66E+05 1.81E+04 1.83E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04
8 2.31E+05 1.75E+04 1.77E+04 1.80E+04 1.84E+04 1.87E+04 1.90E+04
10 1.65E+05 1.70E+04 1.72E+04 1.75E+04 1.78E+04 1.81E+04 1.84E+04
12 2.68E+05 1.77E+04 1.79E+04 1.82E+04 1.86E+04 1.89E+04 1.93E+04

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 4 (4,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
2 1/2 1.14E+06 5.52E+04 5.69E+04 5.86E+04 6.04E+04 6.23E+04 6.39E+04
3 1.38E+06 5.56E+04 5.74E+04 5.91E+04 6.10E+04 6.29E+04 6.46E+04
4 1.25E+06 5.54E+04 5.72E+04 5.89E+04 6.07E+04 6.26E+04 6.42E+04
5 1.54E+06 5.59E+04 5.77E+04 5.94E+04 6.12E+04 6.32E+04 6.49E+04
6 1.05E+06 5.49E+04 5.67E+04 5.84E+04 6.01E+04 6.20E+04 6.36E+04
8 1.03E+06 5.49E+04 5.66E+04 5.83E+04 6.00E+04 6.19E+04 6.35E+04
10 7.55E+05 5.38E+04 5.55E+04 5.71E+04 5.88E+04 6.06E+04 6.21E+04
12 8.16E+05 5.41E+04 5.58E+04 5.74E+04 5.92E+04 6.10E+04 6.25E+04
14 6.78E+05 5.34E+04 5.50E+04 5.66E+04 5.83E+04 6.01E+04 6.16E+04
16 6.15E+05 5.30E+04 5.46E+04 5.61E+04 5.78E+04 5.95E+04 6.10E+04
18 5.71E+05 5.26E+04 5.42E+04 5.58E+04 5.74E+04 5.91E+04 6.05E+04
20 5.00E+05 5.19E+04 5.35E+04 5.50E+04 5.66E+04 5.82E+04 5.96E+04
24 6.06E+05 5.29E+04 5.45E+04 5.61E+04 5.77E+04 5.94E+04 6.09E+04
30 4.40E+05 5.12E+04 5.27E+04 5.42E+04 5.57E+04 5.73E+04 5.87E+04
36 3.74E+05 5.02E+04 5.16E+04 5.30E+04 5.45E+04 5.60E+04 5.73E+04

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 7 (7,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
3 1.27E+06 1.57E+05 1.67E+05 1.77E+05 1.88E+05 2.00E+05 2.11E+05
4 1.30E+06 1.58E+05 1.67E+05 1.77E+05 1.88E+05 2.01E+05 2.12E+05
5 1.89E+06 1.64E+05 1.74E+05 1.85E+05 1.97E+05 2.11E+05 2.24E+05
6 1.49E+06 1.60E+05 1.70E+05 1.80E+05 1.92E+05 2.05E+05 2.17E+05
8 1.21E+06 1.56E+05 1.66E+05 1.75E+05 1.86E+05 1.99E+05 2.10E+05
10 1.25E+06 1.57E+05 1.67E+05 1.76E+05 1.87E+05 2.00E+05 2.11E+05
12 1.00E+06 1.52E+05 1.61E+05 1.70E+05 1.80E+05 1.92E+05 2.02E+05
14 8.43E+05 1.48E+05 1.56E+05 1.65E+05 1.75E+05 1.85E+05 1.95E+05
16 7.87E+05 1.46E+05 1.54E+05 1.63E+05 1.72E+05 1.82E+05 1.92E+05
18 6.73E+05 1.42E+05 1.49E+05 1.57E+05 1.66E+05 1.76E+05 1.84E+05
20 5.93E+05 1.38E+05 1.45E+05 1.52E+05 1.61E+05 1.70E+05 1.78E+05
24 4.86E+05 1.31E+05 1.38E+05 1.44E+05 1.52E+05 1.60E+05 1.67E+05
30 5.47E+05 1.35E+05 1.42E+05 1.49E+05 1.57E+05 1.66E+05 1.73E+05
32 3.80E+05 1.22E+05 1.28E+05 1.33E+05 1.39E+05 1.46E+05 1.52E+05
36 4.07E+05 1.25E+05 1.30E+05 1.36E+05 1.43E+05 1.50E+05 1.56E+05

Size 12 (12,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
3 2.18E+06 2.70E+05 2.99E+05 3.32E+05 3.73E+05 4.26E+05 4.81E+05
4 2.22E+06 2.70E+05 3.00E+05 3.33E+05 3.75E+05 4.28E+05 4.83E+05
5 3.24E+06 2.81E+05 3.13E+05 3.50E+05 3.96E+05 4.55E+05 5.18E+05
6 2.55E+06 2.75E+05 3.05E+05 3.40E+05 3.83E+05 4.39E+05 4.97E+05
8 2.07E+06 2.68E+05 2.97E+05 3.29E+05 3.70E+05 4.22E+05 4.75E+05
10 2.14E+06 2.69E+05 2.98E+05 3.31E+05 3.72E+05 4.25E+05 4.79E+05
12 1.71E+06 2.61E+05 2.88E+05 3.19E+05 3.57E+05 4.05E+05 4.54E+05
14 1.45E+06 2.54E+05 2.80E+05 3.08E+05 3.43E+05 3.88E+05 4.32E+05
16 1.35E+06 2.51E+05 2.76E+05 3.04E+05 3.38E+05 3.80E+05 4.23E+05
18 1.15E+06 2.43E+05 2.67E+05 2.93E+05 3.24E+05 3.63E+05 4.02E+05
20 1.02E+06 2.36E+05 2.59E+05 2.83E+05 3.12E+05 3.48E+05 3.84E+05
24 8.33E+05 2.25E+05 2.45E+05 2.67E+05 2.92E+05 3.24E+05 3.54E+05
30 9.38E+05 2.32E+05 2.53E+05 2.76E+05 3.04E+05 3.39E+05 3.72E+05
32 6.52E+05 2.09E+05 2.26E+05 2.45E+05 2.66E+05 2.92E+05 3.17E+05
36 6.98E+05 2.14E+05 2.32E+05 2.51E+05 2.74E+05 3.01E+05 3.27E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 25 (25,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 26
4 3.25E+06 5.03E+05 5.83E+05 6.82E+05 8.21E+05 1.03E+06 1.26E+06
5 3.62E+06 5.11E+05 5.94E+05 6.97E+05 8.43E+05 1.07E+06 1.31E+06
6 3.47E+06 5.08E+05 5.90E+05 6.91E+05 8.35E+05 1.05E+06 1.29E+06
8 2.98E+06 4.96E+05 5.74E+05 6.69E+05 8.03E+05 1.00E+06 1.21E+06
10 2.96E+05 1.97E+05 2.09E+05 2.20E+05 2.33E+05 2.47E+05 2.58E+05
12 2.78E+06 4.90E+05 5.66E+05 6.59E+05 7.87E+05 9.79E+05 1.18E+06
14 2.66E+06 4.86E+05 5.61E+05 6.52E+05 7.78E+05 9.64E+05 1.16E+06
16 2.38E+06 4.76E+05 5.47E+05 6.34E+05 7.52E+05 9.24E+05 1.10E+06
18 2.25E+06 4.71E+05 5.40E+05 6.24E+05 7.39E+05 9.04E+05 1.07E+06
20 2.07E+06 4.62E+05 5.29E+05 6.09E+05 7.17E+05 8.73E+05 1.03E+06
24 1.75E+06 4.44E+05 5.05E+05 5.78E+05 6.75E+05 8.11E+05 9.44E+05
30 1.27E+06 4.05E+05 4.56E+05 5.14E+05 5.89E+05 6.90E+05 7.84E+05
36 1.32E+06 4.10E+05 4.62E+05 5.21E+05 5.99E+05 7.03E+05 8.01E+05

Size 35 (35,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 30
8 4.27E+06 6.34E+05 7.39E+05 8.70E+05 1.06E+06 1.35E+06 1.56E+06
10 3.80E+06 6.23E+05 7.24E+05 8.49E+05 1.03E+06 1.30E+06 1.49E+06
12 3.18E+06 6.03E+05 6.98E+05 8.13E+05 9.75E+05 1.22E+06 1.39E+06
14 3.24E+06 6.06E+05 7.01E+05 8.17E+05 9.80E+05 1.22E+06 1.40E+06
16 2.78E+06 5.87E+05 6.76E+05 7.84E+05 9.33E+05 1.15E+06 1.31E+06
18 2.69E+06 5.83E+05 6.71E+05 7.77E+05 9.23E+05 1.14E+06 1.29E+06
20 2.27E+06 5.61E+05 6.41E+05 7.38E+05 8.68E+05 1.05E+06 1.18E+06
24 2.08E+06 5.49E+05 6.25E+05 7.17E+05 8.39E+05 1.01E+06 1.13E+06
30 1.88E+06 5.34E+05 6.06E+05 6.91E+05 8.04E+05 9.62E+05 1.07E+06
36 1.73E+06 5.21E+05 5.90E+05 6.70E+05 7.76E+05 9.22E+05 1.02E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 60 (60,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 32
10 5.04E+06 9.39E+05 1.08E+06 1.24E+06 1.46E+06 1.78E+06 1.95E+06
12 5.08E+06 9.40E+05 1.08E+06 1.24E+06 1.46E+06 1.78E+06 1.95E+06
14 4.69E+06 9.26E+05 1.06E+06 1.22E+06 1.43E+06 1.73E+06 1.89E+06
16 4.20E+06 9.05E+05 1.03E+06 1.18E+06 1.38E+06 1.66E+06 1.81E+06
18 4.41E+06 9.15E+05 1.04E+06 1.20E+06 1.40E+06 1.69E+06 1.85E+06
20 3.92E+06 8.92E+05 1.01E+06 1.16E+06 1.35E+06 1.62E+06 1.75E+06
24 3.39E+06 8.61E+05 9.74E+05 1.11E+06 1.28E+06 1.52E+06 1.64E+06
30 3.02E+06 8.34E+05 9.40E+05 1.06E+06 1.22E+06 1.44E+06 1.55E+06
36 2.48E+06 7.87E+05 8.81E+05 9.88E+05 1.12E+06 1.30E+06 1.39E+06

Size 80 (80,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 36
10 7.55E+06 1.49E+06 1.75E+06 2.07E+06 2.54E+06 3.28E+06 3.49E+06
12 6.67E+06 1.45E+06 1.70E+06 2.00E+06 2.43E+06 3.10E+06 3.29E+06
14 6.50E+06 1.45E+06 1.69E+06 1.98E+06 2.41E+06 3.07E+06 3.25E+06
16 5.80E+06 1.41E+06 1.63E+06 1.91E+06 2.31E+06 2.90E+06 3.06E+06
18 5.63E+06 1.40E+06 1.62E+06 1.89E+06 2.28E+06 2.86E+06 3.01E+06
20 4.76E+06 1.34E+06 1.54E+06 1.78E+06 2.12E+06 2.62E+06 2.75E+06
24 4.68E+06 1.33E+06 1.53E+06 1.77E+06 2.11E+06 2.59E+06 2.72E+06
30 3.79E+06 1.25E+06 1.42E+06 1.63E+06 1.90E+06 2.29E+06 2.39E+06
36 3.51E+06 1.22E+06 1.38E+06 1.57E+06 1.83E+06 2.19E+06 2.28E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 5 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with CLAMP 6202

Size 130 (130,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 42
14 8.90E+06 1.95E+06 2.23E+06 2.57E+06 3.03E+06 3.60E+06
16 8.44E+06 1.93E+06 2.20E+06 2.53E+06 2.97E+06 3.52E+06
18 7.78E+06 1.89E+06 2.16E+06 2.47E+06 2.89E+06 3.40E+06
20 7.22E+06 1.86E+06 2.11E+06 2.41E+06 2.80E+06 3.29E+06
24 6.91E+06 1.84E+06 2.08E+06 2.37E+06 2.76E+06 3.23E+06
30 6.07E+06 1.77E+06 2.00E+06 2.27E+06 2.61E+06 3.03E+06
36 5.10E+06 1.68E+06 1.88E+06 2.11E+06 2.41E+06 2.77E+06

Size 200 (200,000 lbf)


Pipe Size 6202 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 52
16 1.39E+07 3.11E+06 3.51E+06 3.99E+06 4.62E+06 4.93E+06
18 1.38E+07 3.10E+06 3.51E+06 3.99E+06 4.61E+06 4.92E+06
20 1.40E+07 3.11E+06 3.52E+06 4.00E+06 4.63E+06 4.95E+06
24 1.31E+07 3.06E+06 3.46E+06 3.92E+06 4.53E+06 4.83E+06
30 1.50E+07 3.16E+06 3.58E+06 4.08E+06 4.74E+06 5.07E+06
36 1.50E+07 3.16E+06 3.58E+06 4.08E+06 4.74E+06 5.07E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 6 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 0.7 (700 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 114 100 80 60 40 18
3 1.17E+06 1.46E+04 1.48E+04 1.50E+04 1.52E+04 1.54E+04 1.56E+04
4 1.00E+06 1.46E+04 1.47E+04 1.49E+04 1.51E+04 1.54E+04 1.56E+04
5 7.78E+05 1.45E+04 1.47E+04 1.49E+04 1.51E+04 1.53E+04 1.55E+04
6 7.00E+05 1.45E+04 1.46E+04 1.48E+04 1.50E+04 1.53E+04 1.55E+04
8 5.00E+05 1.44E+04 1.45E+04 1.47E+04 1.49E+04 1.51E+04 1.54E+04
10 4.12E+05 1.43E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 1.53E+04
12 3.89E+05 1.43E+04 1.44E+04 1.46E+04 1.48E+04 1.50E+04 1.52E+04

Size 1.5 (1,500 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 114 100 80 60 40 18
3 1.36E+06 1.87E+04 1.90E+04 1.93E+04 1.97E+04 2.00E+04 2.04E+04
4 1.15E+06 1.87E+04 1.89E+04 1.93E+04 1.96E+04 2.00E+04 2.04E+04
5 8.33E+05 1.86E+04 1.88E+04 1.91E+04 1.95E+04 1.98E+04 2.03E+04
6 7.50E+05 1.85E+04 1.87E+04 1.91E+04 1.94E+04 1.98E+04 2.02E+04
8 5.56E+05 1.84E+04 1.86E+04 1.89E+04 1.93E+04 1.96E+04 2.00E+04
10 4.41E+05 1.82E+04 1.84E+04 1.87E+04 1.91E+04 1.94E+04 1.98E+04
12 2.24E+05 1.75E+04 1.77E+04 1.80E+04 1.83E+04 1.86E+04 1.90E+04

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 4 (4,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
3 2.11E+06 5.64E+04 5.83E+04 6.00E+04 6.19E+04 6.39E+04 6.56E+04
4 1.74E+06 5.61E+04 5.79E+04 5.97E+04 6.15E+04 6.35E+04 6.52E+04
5 1.29E+06 5.55E+04 5.73E+04 5.90E+04 6.08E+04 6.27E+04 6.43E+04
6 1.14E+06 5.52E+04 5.69E+04 5.86E+04 6.04E+04 6.23E+04 6.39E+04
8 9.09E+05 5.45E+04 5.62E+04 5.79E+04 5.96E+04 6.15E+04 6.30E+04
10 7.14E+05 5.36E+04 5.53E+04 5.69E+04 5.86E+04 6.03E+04 6.19E+04
12 7.02E+05 5.35E+04 5.52E+04 5.68E+04 5.85E+04 6.03E+04 6.18E+04
14 6.15E+05 5.30E+04 5.46E+04 5.61E+04 5.78E+04 5.95E+04 6.10E+04
16 4.82E+05 5.17E+04 5.33E+04 5.48E+04 5.63E+04 5.80E+04 5.94E+04

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 7 (7,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
3 1.15E+06 1.55E+05 1.65E+05 1.74E+05 1.85E+05 1.97E+05 2.08E+05
4 1.43E+06 1.59E+05 1.69E+05 1.79E+05 1.91E+05 2.04E+05 2.15E+05
6 1.27E+06 1.57E+05 1.67E+05 1.77E+05 1.88E+05 2.00E+05 2.11E+05
8 1.15E+06 1.55E+05 1.65E+05 1.74E+05 1.85E+05 1.97E+05 2.08E+05
10 8.33E+05 1.48E+05 1.56E+05 1.65E+05 1.74E+05 1.85E+05 1.94E+05
12 7.78E+05 1.46E+05 1.54E+05 1.62E+05 1.72E+05 1.82E+05 1.91E+05
14 6.19E+05 1.39E+05 1.47E+05 1.54E+05 1.62E+05 1.72E+05 1.80E+05
16 4.83E+05 1.31E+05 1.37E+05 1.44E+05 1.51E+05 1.59E+05 1.66E+05
18 3.70E+05 1.21E+05 1.26E+05 1.32E+05 1.38E+05 1.45E+05 1.51E+05
20 2.92E+06 1.69E+05 1.80E+05 1.92E+05 2.05E+05 2.20E+05 2.33E+05
24 3.93E+05 1.23E+05 1.29E+05 1.35E+05 1.41E+05 1.48E+05 1.54E+05

Size 12 (12,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 24
3 1.97E+06 2.66E+05 2.95E+05 3.27E+05 3.67E+05 4.17E+05 4.70E+05
4 2.45E+06 2.73E+05 3.04E+05 3.38E+05 3.81E+05 4.36E+05 4.93E+05
6 2.18E+06 2.70E+05 2.99E+05 3.32E+05 3.73E+05 4.26E+05 4.81E+05
8 1.97E+06 2.66E+05 2.95E+05 3.27E+05 3.67E+05 4.17E+05 4.70E+05
10 1.43E+06 2.53E+05 2.79E+05 3.08E+05 3.43E+05 3.87E+05 4.31E+05
12 1.33E+06 2.50E+05 2.75E+05 3.03E+05 3.37E+05 3.79E+05 4.22E+05
14 1.06E+06 2.39E+05 2.61E+05 2.86E+05 3.16E+05 3.54E+05 3.90E+05
16 8.28E+05 2.24E+05 2.44E+05 2.66E+05 2.92E+05 3.23E+05 3.53E+05
18 6.35E+05 2.07E+05 2.24E+05 2.42E+05 2.64E+05 2.89E+05 3.13E+05
20 5.00E+06 2.90E+05 3.24E+05 3.63E+05 4.13E+05 4.79E+05 5.49E+05
24 6.74E+05 2.11E+05 2.29E+05 2.48E+05 2.70E+05 2.97E+05 3.22E+05
30 4.27E+05 1.79E+05 1.91E+05 2.04E+05 2.19E+05 2.36E+05 2.52E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 25 (25,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 26
6 3.09E+06 4.99E+05 5.78E+05 6.75E+05 8.10E+05 1.01E+06 1.23E+06
8 2.84E+06 4.92E+05 5.69E+05 6.62E+05 7.92E+05 9.86E+05 1.19E+06
10 2.10E+06 4.64E+05 5.31E+05 6.12E+05 7.21E+05 8.79E+05 1.04E+06
12 2.08E+06 4.63E+05 5.30E+05 6.10E+05 7.19E+05 8.76E+05 1.03E+06
14 1.54E+06 4.30E+05 4.87E+05 5.54E+05 6.42E+05 7.64E+05 8.80E+05
16 1.40E+06 4.17E+05 4.71E+05 5.33E+05 6.15E+05 7.26E+05 8.31E+05
18 1.00E+06 3.74E+05 4.16E+05 4.64E+05 5.25E+05 6.03E+05 6.74E+05
20 8.45E+05 3.49E+05 3.86E+05 4.27E+05 4.78E+05 5.42E+05 5.98E+05
24 7.02E+05 3.22E+05 3.53E+05 3.87E+05 4.28E+05 4.79E+05 5.23E+05
30 7.72E+05 3.36E+05 3.70E+05 4.07E+05 4.53E+05 5.11E+05 5.61E+05
36 6.30E+05 3.06E+05 3.34E+05 3.64E+05 4.00E+05 4.45E+05 4.82E+05

Size 35 (35,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 30
12 2.99E+06 5.96E+05 6.88E+05 8.00E+05 9.56E+05 1.19E+06 1.35E+06
14 2.50E+06 5.74E+05 6.58E+05 7.60E+05 9.00E+05 1.10E+06 1.24E+06
16 2.38E+06 5.67E+05 6.50E+05 7.49E+05 8.84E+05 1.08E+06 1.21E+06
18 2.33E+06 5.65E+05 6.46E+05 7.44E+05 8.77E+05 1.07E+06 1.20E+06
20 2.03E+06 5.45E+05 6.21E+05 7.11E+05 8.31E+05 1.00E+06 1.11E+06
24 2.11E+06 5.50E+05 6.28E+05 7.20E+05 8.43E+05 1.02E+06 1.14E+06
30 1.47E+06 4.94E+05 5.56E+05 6.27E+05 7.19E+05 8.42E+05 9.21E+05
36 1.47E+06 4.94E+05 5.56E+05 6.27E+05 7.19E+05 8.42E+05 9.21E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 60 (60,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 32
12 7.79E+06 1.01E+06 1.16E+06 1.36E+06 1.63E+06 2.03E+06 2.25E+06
14 6.59E+06 9.82E+05 1.13E+06 1.31E+06 1.57E+06 1.94E+06 2.14E+06
16 6.52E+06 9.80E+05 1.13E+06 1.31E+06 1.56E+06 1.93E+06 2.13E+06
18 5.22E+06 9.45E+05 1.08E+06 1.25E+06 1.47E+06 1.80E+06 1.97E+06
20 3.33E+06 8.57E+05 9.69E+05 1.10E+06 1.27E+06 1.51E+06 1.63E+06
24 3.06E+06 8.38E+05 9.45E+05 1.07E+06 1.23E+06 1.45E+06 1.56E+06
30 2.47E+06 7.86E+05 8.80E+05 9.86E+05 1.12E+06 1.30E+06 1.39E+06
36 1.97E+06 7.28E+05 8.07E+05 8.96E+05 1.01E+06 1.15E+06 1.22E+06

Size 80 (80,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 40 36
12 1.07E+07 1.58E+06 1.88E+06 2.25E+06 2.82E+06 3.76E+06 4.03E+06
14 1.14E+06 7.08E+05 7.61E+05 8.16E+05 8.80E+05 9.55E+05 9.72E+05
16 1.05E+07 1.58E+06 1.87E+06 2.25E+06 2.81E+06 3.74E+06 4.01E+06
18 9.52E+06 1.56E+06 1.84E+06 2.20E+06 2.73E+06 3.61E+06 3.86E+06
20 9.64E+06 1.56E+06 1.84E+06 2.20E+06 2.74E+06 3.63E+06 3.88E+06
24 7.69E+06 1.50E+06 1.76E+06 2.08E+06 2.56E+06 3.31E+06 3.52E+06
30 7.21E+06 1.48E+06 1.73E+06 2.04E+06 2.50E+06 3.22E+06 3.41E+06
36 6.61E+06 1.45E+06 1.69E+06 1.99E+06 2.42E+06 3.09E+06 3.27E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 5 OF 6 REV. 1 PART NO. 2250


SPRING RATE INFORMATION SHEET

ADJUSTABLE RIGID STRUT ASSEMBLY with YOKE CLAMP 6175

Size 130 (130,000 lbf)


Pipe Size 6175 Max ** Assembly Pin - Pin (inches) Min
Clamp 122 100 80 60 42
14 1.57E+07 2.16E+06 2.50E+06 2.94E+06 3.55E+06 4.37E+06
16 1.59E+07 2.16E+06 2.51E+06 2.94E+06 3.56E+06 4.38E+06
18 1.44E+07 2.13E+06 2.47E+06 2.89E+06 3.48E+06 4.27E+06
20 1.40E+07 2.12E+06 2.46E+06 2.87E+06 3.45E+06 4.22E+06
24 1.23E+07 2.08E+06 2.40E+06 2.79E+06 3.34E+06 4.05E+06
30 1.13E+07 2.05E+06 2.36E+06 2.74E+06 3.26E+06 3.94E+06
36 9.42E+06 1.98E+06 2.26E+06 2.61E+06 3.08E+06 3.68E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Strut, End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 6 OF 6 REV. 1 PART NO. 2250


rfi J, d
?
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

ADJUSTABLE RIGID STRUT . PART NUMBER 2252

(t 4. Adjustment)

DIRECTIOI{ DIRECTION
OF OF
LOADING LOADING

fu) t
.H ..H

T emperature: 3sooF

Design Spec. No. DS-2100


For the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Report No. DR-2250
temperatures in the Test Condition, use Level B loads up to the temperature
shown for the Operating Condition.

Strut Operating Conditions Test Condition


Size Design Condition
Lenqth * Level A Level B Level C Level D (see Note)
0.7 9',-2n 700 700 931 1,050 1,315 931
r.5 9'-2n 1,500 1,500 1,995 2,250 2,819 1,995
4 9'-10u 4,000 4,000 5,320 6,000 7,516 5,320
7 9'-10" 7,000 7,000 9,310 10,500 13,153 9,310
12 9'-10'. 12,000 12,000 15,960 18,000 22,548 15,960
25 9'-10' 25,000 25,000 33,250 37,500 46,975 33,250
35 9'-10' 35,000 35,000 46,550 52,500 65,765 46,550
60 9'-10" 60,000 60,000 79,800 90,000 112,740 79,800
80 g',-10' 80,000 80,000 106,400 120,000 150,320 106,400
130 9'-10' 130,000 130,000 172,900 195,000 244,270 172,900
200 9'-10n 200,000 200,000 266,000 300,000 375,800 266,000
Rated Loads (lbs) for Classes 1,2,3 &MC

*
Maximum strut length with adjustment, for rated loads shown.

lcertit this CDRS complies with the CONTROL REF NO. 2252
requirements of he applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36, SA515 Gr 70
accordance with ASME BPVC Section lll, Subsection
Rod: SA-36, A108 Gr 1018 (CC N-71)
NF 2007 Edition and are on file at:
Nuts: 3A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe Supporfs, lnc.
Pipe: SA-106 Gr B, SA-53 Gr B
Product Engineering Department
Exempt: Cotter pins, Washers, Retainers {Ifi?l?]l
REVISIONS
/N Oriqinal lssue 1 0/27109 /J
{, ,e' -r- r(r&.* A A
SEAL l747gz/al ISIGNED /z\ /J

BERGEN POWERPIPE SUPPORTS, INC. SHEET 1oF I I nev. /o\ I PART No. 2252
CDRS CATALOG INFORMATION SHEET

ADJUSTABLE RIGID STRUT - PART NUMBER 2252


P-P (± 4" Adjustment)
Cut Length (note 3)
P

Q
Torque Size 0.7 through 12 E70XX R
D (Typ.) Note 6 Swing
Pipe (Nominal Dia.) W (Typ.) Rad.

A
C

Size 25 and 35
S
Part 1000 Note 7

E Cut Length (note 3)

B 10°
U
N E70XX
By Note 6
M W (Typ.)
Customer Size 60, 80, 130, 200
(Typ.)

KIP P-P
A B C D E P PIPE Q M N R S T U W X
SIZE MIN
0.7 1 1/8 1 1/2 9/16 1/2 1 7/8 3/8 22 1 1/2 S/40 15 - - 1 1 1/2 1/2 7/16 1/8 10 7/8
1.5 1 1/2 1 3/4 3/4 1/2 2 1/4 1/2 22 1 1/2 S/40 25 - - 1 1/8 1 3/8 5/8 1/2 1/8 10 7/8
4 1 1/2 1 3/4 3/4 1/2 2 1/4 1/2 28 2 S/80 50 - - 1 1/4 1 9/16 5/8 1/2 3/16 12 1/4
*7 3 1/2 3 1/4 1 1/2 3/4 2 7/8 3/4 28 2 1/2 S/80 100 - - 2 1 3/16 7/8 5/8 1/4 15
* 12 3 1/2 3 1/4 1 1/2 3/4 2 7/8 3/4 28 2 1/2 S/80 100 - - 2 1 3/16 7/8 5/8 1/4 15
25 5 4 1/4 2 1/8 1 3 7/8 1 30 3 S/80 100 - - 2 5/8 3 1 3/8 1 1/4 18
35 5 3/4 5 2 3/8 1 1/4 4 1/4 1 1/4 34 3 1/2 S/80 100 - - 2 5/8 3 1/2 1 1/2 1 1/4 5/16 20
60 7 1/4 6 3 1 1/2 5 5/8 1 1/2 36 5 S/80 100 2 3/4 5/8 3 5/8 3 1/2 1 11/16 1 1/4 3/8 14 9/16
80 9 1/4 7 3/4 3 5/8 1 3/4 6 1/4 1 3/4 40 6 S/80 100 3 1/2 5/8 4 1/8 4 1 13/16 1 1/2 3/8 15 11/16
130 11 5/8 8 7/8 4 5/8 1 3/4 8 1/2 2 1/2 46 8 S/80 100 4 1/8 3/4 6 5 1/4 2 1/16 1 1/2 1/2 19 11/16
200 15 11 1/2 5 1/4 2 3/4 10 3/4 3 58 8 S/160 100 5 5/8 1 1/8 7 1/8 6 1/4 2 5/16 2 7/8 24 1/4
NOTES: 1.) All dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) Cut length = Desired "P-P" - X. All struts are supplied at maximum.
4.) Set strut at desired P-P and tighted nut to the nominal torque value (Q) for locking.
5.) This strut is compatible with B-P Parts 6175, 6202, 6252, 6280, 6525, and 6526.
6.) Weld "W" performed by others after cutting the pipe to suit the desired P-P.
7.) Drill 3/8" dia. sight hole at "M" on cut end only, sizes 60 thru 200.
8.) Configuration is the same on both ends for sizes 25 thru 200 .
* 9.) The 7/12 kip strut use the welded type end attachment.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Kip Size Designation, and P-P Length.
EXAMPLE: 2252-R/0-4k P-P = 30"

REVISIONS
0 Original Issue 10/27/09 3
1 .7k "C", Added Note #9 8/3/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2252


til {Ctl:77

LOAD CAPACITY DATA SHEET


for
NUCTEAR POWEN PIAI{T COTAPONENT STAHDAND SUPPC'TTS
SHORT STRUT ASSEMBLY T{ITIT MSA BY PSC

DIRECTION
c)F
TOADING
LOAD RATING &
1949_RAING_[bd
DESIGNED BY: LINEAR ANALYSIS cl. r,2.3,8MC TEMPERAruRE 350 oF

OPERATING CONDITIONS
DESIGN I.EVEI A & B IEVEI C TEVEI D
SIZE CONDITION NORMAT & UPSET E,MERGENCY FAUTTED

.35 350 350 450 500


Ig\ 650 550 450 850
"65
1.5 1 500 1 500 2000 2100
6"0 6000 6000 8000 9000
15- 0 15000 15000 20000 22140
-
q
I
u
c\
I
\l

o
!-
o
}J
o
= 3tnr colcul.floir ce torl ddc lor thb producr
Moierlolr: ren prr{ororrd ln occoedcnco wllh:
\ As.m.e sECilON ilt.SUtStCnOil ilt
-ri COmAOil:tfT $l?lOr|ll (dctr C lrrr t l-t7)
oad orooa lllo cl:

Mechanical Snubber: Pacific


ll,
Iaa lcientific DR1501 I;Effi
fuBEncEN-PArERsoN
2 FSffi? I ttco*it xcr xtttttraG ot2te -u 3
^
g ! CONTROL REF. NO. 2420
4
o
,,^:'wutffi] BCNGEN?A'CNSON PIPESUPPOn? CORP.
lolo catAcltl Dltl 3tlttt
$l:r.t
1ot1 b ?Attllo.
2420
--l
i
4ET j

EF
ra ?o
gwrrfG RADIUS

PARt toot TORQUE q BY BP.


$tzE 6,t5
(A T' I n s r A r. I r r i b ru I
PSA
L I
SIZE PART NO. STK A B c D F
MTN It{ P IN- R S T U rJ
LBS.
1801104-05 4 I ti 'l J
8
1J 9 ,* J
22 !I 1* 1
l4 3
"35 (PsA- 1/4 ) 2 8 8 T 8
"65
180r104-07 2;
(PSA-1/2)
1
i 1

)
L
I ,* 7.5 ,l II 22 Z
8
1:
1

B
I2 I4 Itt
1.5 180 I 102-05
( PSA-3 )
4
i 4 L
4
L
2
15
4
ll 3+
I
2
45 1 11
2
:
I lI :l
z
6
1801106-05
(PSA-3)' 5 tln ,l .'* E
R
,i 14.-t €
I4 120 ,i ,: 7
s
1
)
:5
,S
180 1 rO3-0? 6 5- 2; I 3t l4
15

NOTES.
(PSA-101 ^l
*:t l=f, nin. * set DosiEion
1'7 .
'i I 440
,1e
i l: I

1. Rll dimensions are in inches.


2. Dimensions provided for user applicatj_L-on onlv.
3. Each PSA snubber has a scale to indicate the numlir of inches of extension. The
scale is uncovered as the snubber is extended- To determine the scale reading
(set position) at instaltation use the appli.cation formula.

For extension, set position stroke - moyement (Use if thermaL movement from cold
= to hot will cause the snubber
to extend. )
+ (Use if thernral movement from colcl
For retraction, set position - stro\e movement to hot will cause the snubber
to ret.ract. )
4. This assenbly is compatible with BP Parrs 6175, 62Q2, 6252, 628Q, 6520 , 6521 ,
6es23, 6526, 6410, 1000.

ORDERING INSTRUCIIONS :

Specify Part No., Load Capacity Data Sheet Rev. Irle-, Size Designition, .Stroke, Thernal
Mvt. .(Extension or Retraction), "L". Dim., & P-P at S€C position - ex : 242O-R1'l -6 ,
stroke=S", tilvt=l-1/2" E:;f-t., L=l6", p-p.*18-t/4".

BENGEN+ATERSC'N PIPE SUPPIOIT CORP.


DATE 4-1-87
IOAD CAPACITY DATA SHEET
lor
NUCLEAI POWER PLAilT COT,IPOilEilT STAT{DAID SUPPONTS
SHORT STRUT ASSEI{BI,Y WITH MSA BY PSC

DIREC'ION
OF
LOADING
LOAD RATING & LOAO RATING 0br.l
DESIGNED 8Y: LINEAR AIIALYSIS cl. r,2.3, tMc TEMPERATUR6 350 o6

OPERATING CONDITIONS
DESIGN rEvEt A t I tEvE[ c IEVET D
srzE. CONDITION NORMA! t UPSET EMERG€NCY FAUTTED

50 50000 50000 66600 72400


120 120000 1 20000 160000 1 60000

Strrrt cokuldlont o?l.d ff. ior filr producl


lere podonnrd ln ociordonco wlti:
AJ-m.:. 3ECfl Oil fi . 3U!SCCnO!{ Hr
Pin: 5A-564, TYP. 630 cbflFoilalfi 3rt?'o|t3 (dolr ol lttl,. 7.1.77)
rad rrrcrl[e ct:
ss: Mechanical Snubbbi! Pacific
ut
:,
lt,
I
fr' Scientific. per PSC CDRS DR1601
LACOdrl
BERGEN.PATERSON
,t atua(qt corDutTo|
NCd dttathtaa cJz.t r- t 4

o CONTROL REF. NO. 2421


c
o ttnGt lr.PAftrtoN PlPtsuPPOrt conP
tolDCrrrclrl oeri $lttl ,
onorrEot zo FT-LBs
l- I
nwll{o FAOltlg

/r:-leuil llZE 60
!'-ltUil tlZE l2O

FAFT t00t

,TL Mi1n 5e o5 on-


*
KIP PSA
P' r_P 'R
STK A B c D E L M S T U w
SIZE PART !,1O.
min hln

-5 _L ,1i
50 1801 1
rpsa- iq)
12-09 6 ?* 6 3 L+ s* 24 6
+ '+ 5F
5 -L6 4 L+

t20 18011i9-09 6 tt; * 45


'8 LI 8+ 29 tt
,8 ,+ t+ 6 -1
-4
.,L
-16 9
+
/psl- r nnr
* P-P (lutax) = P-P (tlin) + St,roke
NOTES.

1- Q=150 ft. lbs. Size 50 and Size 12O - to be torqued at installation.


2- All dinensions are in inches.
3, Dinensions are providgd for user application only.
4- Each PSA Snubber has a scale to indicate the nurnber of inches of extension.
The scale is uncovered as the snubber is extencied. To deter:nine the scale
reading (Set position) at installation, use the applicable .forrnuia.
For extension, set position = Stroke-Movenent - (Use if therslal novernent
2 from cold to ilot wiil
cause the snubber to
extend. )

For retracti.on, set position = Stroke + Movement- (Use if thernal move!;rent


2 from cold to hot uill
cause the snubber to
retract . )

5. This assereb'ly is conpatible'with B/P Farts 6175, 6202, 6252, 628Q, 1000.
Ordering Instructions :
Specify Part No., Load Canacity Data Sheet Rev". No., Size designation, stroke,
thermal novenent (Extension or Retraction), [Lrr Dimension, and Pin to Pin at
set position. EXAITIPLE: Patt 2421-R/0, Stroke=6ri, l'lvt=2t' (P.etraction),L=28",P-P=58f'
PAnf 242t
BGNGEilfATENSON PIPE SUPFOffi CONP.
IOAD CAPACITY DATA SHEET
lor
NUCLEAN POWEN PTANT COTiPONENT STANDARD SUPPOTTS
STRUT ASSEI'IBLY WITH PSC MSA

DlnECNON
OF
TOADINC
LOAD RAING (lbg.l
OCSIGNEDBY: Linear Analysis cl. r.2.3,8MC TEMpERATURS 300 op

O P E R A T I N'G C O N D I T IO N S
S TRUT *a tEvct A I I r.EvEt c I,EVEt D
stzE LEN GTH NORMAT & UPSEI EMERGENCY FAUTTED

.35 7' - ott 350 450 500


.65 7t - 0,t 550 850 850
l-5 l0' 0r' !.500 2000 2LOA
6 1-2t - 0rr 6000 8000 9000
l5 ltr - nll 15000 20000 22LOO
50 13' - o" 50000 66600 72400
12o' l4r - 0rr 120000 160000 160000

d
6
L
o
r,
qt


k .-,
(u 0{
+r c
strut length for rated Ioads shsrn with transverse acceleration ( lc
q, o
Ff .i* Max.
0,
&
rJ Code Case N-55 lpplies. A
.J .b
tlrrlr cdculdlorr cr tll drlo lilr poducl
ftlotorlob: Plate: sA36 , SA5I5Gr.
A. l:l 0or
r.r. tarlonnoa In cccdorco wlilr:
Rod: 5A36'A108 Gr.1018 * A.t-mr. $cflo}l n. tursrctlor ilt
pipe: SA.53. 6t.3 *(Co<ie Case i{ )COFoilEm $t?om3 (dd. ol hr. 7-l.m
cdcrlcrlllorr:
Pin: 5A564 TYP.
bolts: A574 (Code Case N-249
tll
D ^lirF6^ Nuts: SA3O7 Gr.B M"rrGEN-PArERsoN
I ?tzatatatca,/ril.tton
rA
I {.r"rrS tarx^aatdtrE
L^CO'at.^ ta, x^aatdtre ot2.a.u
0t2.a.u s a
^
E CONTROL REF. NO. 2440
E -- trfitr
o tlt/t;..orto EEROEll-PAtEnSClll
LC)IO Clract?l DltA llltlT 1or I
P-P(r2") J
(SW ING
FRW.35&.65 PIPE
(NOM. DIA) FRW RADIUS}
Y BYBP srzEs R
USTOMER -1.5-15 w .95-15
M
BY BP
T-
A'r 1
/
\

P
QT (NOTE 4'.
BY CUSTOMER
Q2 (NOTE 5''
PIPE
E L** M
(NOM. DIA)
BY
BP
l*s
TYP. TW
Ll
TT
BY BP TYP.. ol BY BP
(srzEs r s-i aoi
Q2 BY stzEs 50&120
BP
L**
**.L_{ MINhSET POSITION
.:,.--
THIS CONFIGURATION sr4Es so8120 oNLY

[ote
D-D
3
0^
KIP L
SIZE
PSC
PAnt ilo. I B c D E .trll t{ P !t tlt u.Ax P IPE ,11""" rrilss R s STROKE T U

rI I
.35 t80 r 104-05 I rI 1

7
3
6 rt 9 zl 3
6 23 a4 rt, s/40 r5 2 lt
2 ie
7

rt zl I 7
.65 18011 o4-0? I rt 2
I 3
6 rI -l 3 2l 84
7.5 aE 6 rt" s/40 I5 2 I 2 16

rt I
1.5 l80rlo2-05 rt rI 3
h
I
z Q II {
L
z 23 L2( rt" sroo 35 4 r$ 4
5
6 2

6 r80r 106-05 zL6 -I


.T rI 5
z! 14.5 al 3
4
29 L41 et" srao 100 l0 2 zl 5
7
6
5
6
E

r5 l80l 103-07 5 tl zI 1
{ r?. r sl t 34 144 3n s/80 100 36 zl 3 6 r$

.1r rI
50 r80ll12-rl fi 6 3 rI .5 z4
t6 6 rI q6 .56 5F S/80 100 150
'i { 6 -16

120 t80rlr9-11 r16


t
e$ e] rf { ,o
C
r6 '2 ,! 55 t68 8i s/80 roo r50 6 -l
t6 6 ^I
-r6 r!

BERCEI{fATERSOil PIPE SUPP|ORT CORP.


DATE "n-rs-eJ
NOTES:

1. All dimensions are in inches.


2. Di:nensions are Provided for user aPglication onllz'
3. P-P uinirouu will be increased bv the set position'
4- Set P-P at desired position and tighten nut to nominal torgue "ttt" (=Qf) for
locking.
5. Torgue at installation to nominal torque value t=QZ)'
6. Each pSA snubber has a scale to indicate the number of inches of extension-
The scale is uncovered as the snubber is extended. To determine the scale
reading (set position) at installation use the apPlicable formula-

Forextension,setposi'tio,'=#.:ilu'|".ffiffil'l":il::..fi.'
snubber to extend. )
stroke + qolgneg! (use if thermal movement from
For retraction, set Position = cold to hot $rill cause the
snubber to retract. )

7. This assenbly is compatible with B-P Parts 10oo; 6L75,6202,6252' 6280,6525r


6526.

ORDERING INSTRUCTIONS :

specify Part. No., Load ca.pacity Data sheet Revision No' , Slze Designation.
Slroke, Thermal Movement (Extension or Retraction), "L" Dimension, and P-P
at set position. ( Pricing wilt be in two parts. ie: Attachnents and PSA
urnits. )
Exanrple: ParL2440-R/'3- 6- StrOke = 5", Mvt. = 2" Ext" L=16tr' P-P= 36"

PARI 2440
BERGENfATERSON PIPE SUPP(ORT CORP. DATE rI-r.g-sz
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tit J' d
b
CDRS CATALOG INFORMATION SHEET

SHORT HYDRAUUC S'I'U8BER ASSEI'BLY - PARr NUHBER 2826.6"

f-
A

L
PART 1OO3

t-
B

L
fi:;:l$Mmffi*
.,,,,,,utllJlll1,,,,
u'k&, * R T w
KIP SIZE A D E P P.P

100 6 illfl, 7 7/8nifilh|Ill'15 13 3/8 71t4 21t2 55 1t16 7 3t8 2 1116 1 112
150 .,rrl|lt1/4\ 8 5/8*l{' 161t2 14314 8718 21t2 57 114 748 2 1t16 1 112
250 .,1611x" tgllP ilrl.,sfiItll0 18112 16 3/4 11 3 61114 I5/8 2 5t16 2
l}',il

Preset Equetion't

in inches and torque in foot pounds. Tendon = Stoke-Movement


irted lor user application only. 2
2"
is compatible with B-P Parts 1000, 6175,6202,6252, and 6280. Compresslon = Stoke + Mqrvement
maintenance manual lor installation and operation instructions. 2

' 6.) the P-P [rAX dimoGslon is b6ed o0 lhe Pisbn d cenEr strok8'
7.)'The Cy'inder Sfol6 21.2 x irowment.

oRDERtirc [rsTRucIloils:
gze D€signalion, Diruclirn (Comprcsion/fensbn),
Specify: Part Number, CDRS RoYision Number, Kip
Prulct ffd Movement

EXA PLE: 2826{-R/0-100 Dirsdion = Tension Presct= 21/f Mwttt=11//

I'lt
PrcImhw lssue,ln7rlo l/r\l
/il /t
A /]
BERGE U.POWER PIPE SUPPORTS, INC, SHEET I OF I REv. a PART NO. 2E2S6
lir J, d
E
CDRS CATALOG INFORMATION SHEET

SHORT HYDRAUL'C STUBBERASSEI'BLY . PART NUMBER 282610"

t-
t
A

PART 1OO3
L R
Swing
Rad.

f-
B

'*hlh," {,'u,$, P.P


* R T w
KIP SIZE A D E P

tm 6 rn'' t tn'qg$$.15 13 3/8 7114 21n 601t2 7 3/8 2 1t16 11t2


150 ,ir$iilI1/4"til I5/ft*w 16112 143t4 8718 2ffi 62ffi 7 3t8 2 1/16 11t2
250 .rrlil$"' 1..0tlF' l,il.*rflill6 18112 18 3/4 11 3 66 1/2 I5/8 2 5/16 2

PF**,Equation'r

in indtes and torque in loot Pounds, Tenglon = Stoke-Movement


for user application only. 2
2:
is compatible with B-P Parts 1000, 6175,6202,6252, and 6280. Compreeelon = Stoke+ Movement
2
maintenance manual lor installation and operation instructions.
' 6.) The P-P MAX dimalgm is basod on he Pist at slbr strcke
7.) The Cy'hder Sfrols :
1.2 x Mov€mcnt.

ORDERI]IG II{STRUGTIOIIS:
sp€city: Part Numbsf, CDRS Revinlln Number, lcp sik6 D€ignalion, Dir€C{On (comPression/Tensbo),
Pteset and Mo\iemenl.

EIA PLE: 282F1FR/['1m Di€c{00 = Tension PEset =11/4' MYmt=I1E

/r\ /t
ZT /J

BERG EN''POWER PIPE SUPPORT$, lNC. SHEET 1 OF r REv. a PART No. 2826.10
SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 2 (2,000 lbf)


Pipe Size 6202-4k Max **Assy. Pin - Pin (inches) Min
Clamp 66 50 38
2 1/2 1.14E+06 1.84E+04 1.85E+04 1.86E+04
3 1.38E+06 1.85E+04 1.86E+04 1.87E+04
4 1.25E+06 1.84E+04 1.86E+04 1.87E+04
5 1.54E+06 1.85E+04 1.86E+04 1.87E+04
6 1.05E+06 1.84E+04 1.85E+04 1.86E+04
8 1.03E+06 1.84E+04 1.85E+04 1.86E+04
10 7.55E+05 1.83E+04 1.84E+04 1.85E+04
12 8.16E+05 1.83E+04 1.84E+04 1.85E+04
14 6.78E+05 1.82E+04 1.83E+04 1.84E+04
16 6.15E+05 1.82E+04 1.83E+04 1.84E+04
18 5.71E+05 1.81E+04 1.82E+04 1.84E+04
20 5.00E+05 1.80E+04 1.82E+04 1.83E+04
24 6.06E+05 1.81E+04 1.83E+04 1.84E+04
30 4.40E+05 1.79E+04 1.81E+04 1.82E+04
36 3.74E+05 1.78E+04 1.79E+04 1.80E+04

Size 3 (3,000 lbf)


Pipe Size 6202-4k Max **Assy. Pin - Pin (inches) Min
Clamp 66 50 38
2 1/2 1.14E+06 4.40E+04 4.48E+04 4.54E+04
3 1.38E+06 4.43E+04 4.51E+04 4.57E+04
4 1.25E+06 4.41E+04 4.49E+04 4.55E+04
5 1.54E+06 4.44E+04 4.52E+04 4.58E+04
6 1.05E+06 4.38E+04 4.46E+04 4.52E+04
8 1.03E+06 4.38E+04 4.46E+04 4.52E+04
10 7.55E+05 4.31E+04 4.39E+04 4.44E+04
12 8.16E+05 4.33E+04 4.41E+04 4.46E+04
14 6.78E+05 4.29E+04 4.36E+04 4.42E+04
16 6.15E+05 4.26E+04 4.33E+04 4.39E+04
18 5.71E+05 4.24E+04 4.31E+04 4.36E+04
20 5.00E+05 4.19E+04 4.26E+04 4.32E+04
24 6.06E+05 4.25E+04 4.33E+04 4.38E+04
30 4.40E+05 4.14E+04 4.21E+04 4.26E+04
36 3.74E+05 4.08E+04 4.14E+04 4.19E+04
NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 4 REV. 1 PART NO. 2830


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 9 (9,000 lbf)


Pipe Size 6202-12k Max **Assembly Pin - Pin (inches) Min
Clamp 90 70 50 43
3 2.18E+06 1.07E+05 1.11E+05 1.15E+05 1.16E+05
4 2.22E+06 1.07E+05 1.11E+05 1.15E+05 1.16E+05
5 3.24E+06 1.08E+05 1.12E+05 1.17E+05 1.18E+05
6 2.55E+06 1.07E+05 1.11E+05 1.16E+05 1.17E+05
8 2.07E+06 1.06E+05 1.10E+05 1.14E+05 1.16E+05
10 2.14E+06 1.07E+05 1.10E+05 1.15E+05 1.16E+05
12 1.71E+06 1.05E+05 1.09E+05 1.13E+05 1.15E+05
14 1.45E+06 1.04E+05 1.08E+05 1.12E+05 1.13E+05
16 1.35E+06 1.03E+05 1.07E+05 1.11E+05 1.13E+05
18 1.15E+06 1.02E+05 1.06E+05 1.10E+05 1.11E+05
20 1.02E+06 1.01E+05 1.04E+05 1.08E+05 1.10E+05
24 8.33E+05 9.88E+04 1.02E+05 1.06E+05 1.07E+05
30 9.38E+05 1.00E+05 1.04E+05 1.07E+05 1.09E+05
32 6.52E+05 9.57E+04 9.88E+04 1.02E+05 1.03E+05
36 6.98E+05 9.66E+04 9.98E+04 1.03E+05 1.04E+05

Size 16 (16,000 lbf)


Pipe Size 6202-25k Max **Assembly Pin - Pin (inches) Min
Clamp 111 90 70 47
4 3.25E+06 1.74E+05 1.81E+05 1.88E+05 1.96E+05
5 3.62E+06 1.75E+05 1.82E+05 1.89E+05 1.98E+05
6 3.47E+06 1.75E+05 1.81E+05 1.88E+05 1.97E+05
8 2.98E+06 1.73E+05 1.80E+05 1.87E+05 1.95E+05
10 2.96E+05 1.13E+05 1.16E+05 1.19E+05 1.22E+05
12 2.78E+06 1.72E+05 1.79E+05 1.86E+05 1.94E+05
14 2.66E+06 1.72E+05 1.79E+05 1.85E+05 1.94E+05
16 2.38E+06 1.71E+05 1.77E+05 1.84E+05 1.92E+05
18 2.25E+06 1.70E+05 1.76E+05 1.83E+05 1.91E+05
20 2.07E+06 1.69E+05 1.75E+05 1.82E+05 1.90E+05
24 1.75E+06 1.66E+05 1.73E+05 1.79E+05 1.87E+05
30 1.27E+06 1.61E+05 1.66E+05 1.72E+05 1.79E+05
36 1.32E+06 1.61E+05 1.67E+05 1.73E+05 1.80E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 4 REV. 1 PART NO. 2830


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 25 (25,000 lbf)


Pipe Size 6202-25k Max **Assembly Pin - Pin (inches) Min
Clamp 111 90 70 49
4 3.25E+06 2.17E+05 2.28E+05 2.39E+05 2.51E+05
5 3.62E+06 2.18E+05 2.29E+05 2.40E+05 2.53E+05
6 3.47E+06 2.18E+05 2.29E+05 2.40E+05 2.53E+05
8 2.98E+06 2.16E+05 2.26E+05 2.37E+05 2.50E+05
10 2.96E+05 1.30E+05 1.34E+05 1.38E+05 1.42E+05
12 2.78E+06 2.15E+05 2.25E+05 2.36E+05 2.48E+05
14 2.66E+06 2.14E+05 2.24E+05 2.35E+05 2.47E+05
16 2.38E+06 2.12E+05 2.22E+05 2.32E+05 2.45E+05
18 2.25E+06 2.11E+05 2.21E+05 2.31E+05 2.43E+05
20 2.07E+06 2.09E+05 2.19E+05 2.29E+05 2.41E+05
24 1.75E+06 2.05E+05 2.15E+05 2.24E+05 2.36E+05
30 1.27E+06 1.96E+05 2.05E+05 2.14E+05 2.24E+05
36 1.32E+06 1.98E+05 2.06E+05 2.15E+05 2.26E+05

Size 40 (40,000 lbf)


Pipe Size 6202-35k Max ** Assembly Pin - Pin (inches) Min
Clamp 146 120 100 80 60 54
8 4.27E+06 3.11E+05 3.27E+05 3.40E+05 3.55E+05 3.71E+05 3.76E+05
10 3.80E+06 3.08E+05 3.24E+05 3.37E+05 3.52E+05 3.67E+05 3.72E+05
12 3.18E+06 3.03E+05 3.18E+05 3.31E+05 3.45E+05 3.61E+05 3.65E+05
14 3.24E+06 3.04E+05 3.19E+05 3.32E+05 3.46E+05 3.61E+05 3.66E+05
16 2.78E+06 2.99E+05 3.14E+05 3.26E+05 3.40E+05 3.55E+05 3.59E+05
18 2.69E+06 2.98E+05 3.13E+05 3.25E+05 3.39E+05 3.53E+05 3.58E+05
20 2.27E+06 2.92E+05 3.06E+05 3.18E+05 3.31E+05 3.45E+05 3.49E+05
24 2.08E+06 2.89E+05 3.02E+05 3.14E+05 3.27E+05 3.40E+05 3.45E+05
30 1.88E+06 2.84E+05 2.98E+05 3.09E+05 3.21E+05 3.34E+05 3.39E+05
36 1.73E+06 2.81E+05 2.94E+05 3.05E+05 3.17E+05 3.29E+05 3.33E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 3 OF 4 REV. 1 PART NO. 2830


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 60 (60,000 lbf)


Pipe Size 6202-60k Max ** Assembly Pin - Pin (inches) Min
Clamp 170 140 120 100 80 58
10 5.04E+06 4.25E+05 4.61E+05 4.89E+05 5.20E+05 5.55E+05 6.00E+05
12 5.08E+06 4.25E+05 4.62E+05 4.89E+05 5.20E+05 5.56E+05 6.01E+05
14 4.69E+06 4.22E+05 4.58E+05 4.85E+05 5.16E+05 5.51E+05 5.95E+05
16 4.20E+06 4.18E+05 4.53E+05 4.79E+05 5.09E+05 5.43E+05 5.86E+05
18 4.41E+06 4.20E+05 4.55E+05 4.82E+05 5.12E+05 5.47E+05 5.90E+05
20 3.92E+06 4.15E+05 4.49E+05 4.76E+05 5.05E+05 5.38E+05 5.81E+05
24 3.39E+06 4.08E+05 4.41E+05 4.67E+05 4.95E+05 5.27E+05 5.67E+05
30 3.02E+06 4.02E+05 4.34E+05 4.59E+05 4.86E+05 5.17E+05 5.56E+05
36 2.48E+06 3.91E+05 4.21E+05 4.44E+05 4.70E+05 4.99E+05 5.34E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 4 OF 4 REV. 1 PART NO. 2830


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 100 (100,000 lbf)


Pipe Size 6202-80k Max ** Assembly Pin - Pin (inches) Min
Clamp 170 140 120 100 80 70
10 7.55E+06 5.40E+05 5.67E+05 5.87E+05 6.08E+05 6.30E+05 6.42E+05
12 6.67E+06 5.35E+05 5.62E+05 5.81E+05 6.01E+05 6.23E+05 6.35E+05
14 6.50E+06 5.34E+05 5.60E+05 5.79E+05 6.00E+05 6.22E+05 6.33E+05
16 5.80E+06 5.29E+05 5.55E+05 5.73E+05 5.93E+05 6.15E+05 6.26E+05
18 5.63E+06 5.27E+05 5.53E+05 5.72E+05 5.91E+05 6.13E+05 6.24E+05
20 4.76E+06 5.18E+05 5.43E+05 5.61E+05 5.80E+05 6.01E+05 6.11E+05
24 4.68E+06 5.17E+05 5.42E+05 5.60E+05 5.79E+05 5.99E+05 6.10E+05
30 3.79E+06 5.04E+05 5.28E+05 5.45E+05 5.63E+05 5.82E+05 5.92E+05
36 3.51E+06 4.99E+05 5.22E+05 5.38E+05 5.56E+05 5.75E+05 5.85E+05

Size 150 (150,000 lbf)


Pipe Size 6202-130k Max ** Assembly Pin - Pin (inches) Min
Clamp 122 110 100 90 80 72
14 5.48E+06 6.66E+05 6.82E+05 6.96E+05 7.10E+05 7.25E+05 7.38E+05
16 5.19E+06 6.61E+05 6.77E+05 6.91E+05 7.05E+05 7.20E+05 7.33E+05
18 4.79E+06 6.54E+05 6.70E+05 6.83E+05 6.97E+05 7.12E+05 7.24E+05
20 4.44E+06 6.48E+05 6.63E+05 6.76E+05 6.89E+05 7.04E+05 7.16E+05
24 4.26E+06 6.43E+05 6.58E+05 6.71E+05 6.85E+05 6.99E+05 7.10E+05
30 3.74E+06 6.30E+05 6.45E+05 6.57E+05 6.70E+05 6.83E+05 6.94E+05
36 3.14E+06 6.10E+05 6.24E+05 6.36E+05 6.48E+05 6.60E+05 6.71E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 2 REV. 1 PART NO. 2831


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 250 (250,000 lbf)


Pipe Size 6202-200k Max ** Assembly Pin - Pin (inches) Min
Clamp 122 110 100 90 80 82
16 1.39E+07 9.61E+05 9.81E+05 9.97E+05 1.01E+06 1.03E+06 1.03E+06
18 1.38E+07 9.61E+05 9.80E+05 9.97E+05 1.01E+06 1.03E+06 1.03E+06
20 1.40E+07 9.62E+05 9.81E+05 9.98E+05 1.02E+06 1.03E+06 1.03E+06
24 1.31E+07 9.57E+05 9.76E+05 9.93E+05 1.01E+06 1.03E+06 1.02E+06
30 1.50E+07 9.66E+05 9.86E+05 1.00E+06 1.02E+06 1.04E+06 1.03E+06
36 1.50E+07 9.66E+05 9.86E+05 1.00E+06 1.02E+06 1.04E+06 1.03E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 2 REV. 1 PART NO. 2831


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 100 (100,000 lbf)


Pipe Size 6202-80k Max ** Assembly Pin - Pin (inches) Min
Clamp 170 140 120 100 80 70
10 7.55E+06 5.40E+05 5.67E+05 5.87E+05 6.08E+05 6.30E+05 6.42E+05
12 6.67E+06 5.35E+05 5.62E+05 5.81E+05 6.01E+05 6.23E+05 6.35E+05
14 6.50E+06 5.34E+05 5.60E+05 5.79E+05 6.00E+05 6.22E+05 6.33E+05
16 5.80E+06 5.29E+05 5.55E+05 5.73E+05 5.93E+05 6.15E+05 6.26E+05
18 5.63E+06 5.27E+05 5.53E+05 5.72E+05 5.91E+05 6.13E+05 6.24E+05
20 4.76E+06 5.18E+05 5.43E+05 5.61E+05 5.80E+05 6.01E+05 6.11E+05
24 4.68E+06 5.17E+05 5.42E+05 5.60E+05 5.79E+05 5.99E+05 6.10E+05
30 3.79E+06 5.04E+05 5.28E+05 5.45E+05 5.63E+05 5.82E+05 5.92E+05
36 3.51E+06 4.99E+05 5.22E+05 5.38E+05 5.56E+05 5.75E+05 5.85E+05

Size 150 (150,000 lbf)


Pipe Size 6202-130k Max ** Assembly Pin - Pin (inches) Min
Clamp 122 110 100 90 80 72
14 5.48E+06 6.66E+05 6.82E+05 6.96E+05 7.10E+05 7.25E+05 7.38E+05
16 5.19E+06 6.61E+05 6.77E+05 6.91E+05 7.05E+05 7.20E+05 7.33E+05
18 4.79E+06 6.54E+05 6.70E+05 6.83E+05 6.97E+05 7.12E+05 7.24E+05
20 4.44E+06 6.48E+05 6.63E+05 6.76E+05 6.89E+05 7.04E+05 7.16E+05
24 4.26E+06 6.43E+05 6.58E+05 6.71E+05 6.85E+05 6.99E+05 7.10E+05
30 3.74E+06 6.30E+05 6.45E+05 6.57E+05 6.70E+05 6.83E+05 6.94E+05
36 3.14E+06 6.10E+05 6.24E+05 6.36E+05 6.48E+05 6.60E+05 6.71E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 2 REV. 1 PART NO. 2831


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with CLAMP 6202

Size 250 (250,000 lbf)


Pipe Size 6202-200k Max ** Assembly Pin - Pin (inches) Min
Clamp 122 110 100 90 80 82
16 1.39E+07 9.61E+05 9.81E+05 9.97E+05 1.01E+06 1.03E+06 1.03E+06
18 1.38E+07 9.61E+05 9.80E+05 9.97E+05 1.01E+06 1.03E+06 1.03E+06
20 1.40E+07 9.62E+05 9.81E+05 9.98E+05 1.02E+06 1.03E+06 1.03E+06
24 1.31E+07 9.57E+05 9.76E+05 9.93E+05 1.01E+06 1.03E+06 1.02E+06
30 1.50E+07 9.66E+05 9.86E+05 1.00E+06 1.02E+06 1.04E+06 1.03E+06
36 1.50E+07 9.66E+05 9.86E+05 1.00E+06 1.02E+06 1.04E+06 1.03E+06

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 2 OF 2 REV. 1 PART NO. 2831


SPRING RATE INFORMATION SHEET

HYDRAULIC STRUT ASSEMBLY with YOKE CLAMP 6175

Size 100 (100,000 lbf)


Pipe Size 6175-80k Max ** Assembly Pin - Pin (inches) Min
Clamp 170 140 120 100 80 70
12 1.07E+07 5.52E+05 5.80E+05 6.00E+05 6.22E+05 6.46E+05 6.58E+05
14 1.14E+07 5.54E+05 5.82E+05 6.03E+05 6.25E+05 6.48E+05 6.61E+05
16 1.05E+07 5.51E+05 5.79E+05 6.00E+05 6.22E+05 6.45E+05 6.58E+05
18 9.52E+06 5.48E+05 5.76E+05 5.96E+05 6.18E+05 6.41E+05 6.53E+05
20 9.64E+06 5.49E+05 5.76E+05 5.97E+05 6.18E+05 6.42E+05 6.54E+05
24 7.69E+06 5.41E+05 5.68E+05 5.87E+05 6.08E+05 6.31E+05 6.43E+05
30 7.21E+06 5.38E+05 5.65E+05 5.84E+05 6.05E+05 6.28E+05 6.39E+05
36 6.61E+06 5.35E+05 5.61E+05 5.80E+05 6.01E+05 6.23E+05 6.34E+05

Size 150 (150,000 lbf)


Pipe Size 6175-130k Max ** Assembly Pin - Pin (inches) Min
Clamp 120 110 100 90 80 72
14 9.64E+06 7.03E+05 7.18E+05 7.33E+05 7.49E+05 7.66E+05 7.80E+05
16 9.76E+06 7.03E+05 7.18E+05 7.34E+05 7.50E+05 7.67E+05 7.81E+05
18 8.89E+06 6.98E+05 7.13E+05 7.28E+05 7.44E+05 7.61E+05 7.75E+05
20 8.60E+06 6.97E+05 7.11E+05 7.26E+05 7.42E+05 7.59E+05 7.72E+05
24 7.55E+06 6.89E+05 7.03E+05 7.18E+05 7.33E+05 7.49E+05 7.63E+05
30 6.96E+06 6.84E+05 6.98E+05 7.12E+05 7.27E+05 7.43E+05 7.56E+05
36 5.80E+06 6.70E+05 6.84E+05 6.98E+05 7.12E+05 7.28E+05 7.40E+05

NOTES:
1.) Spring Rates = lbs. / inch.
** 2.) Assembly Pin - Pin data (Max through Min) includes the overall Spring Rate for the assembly at the Struts specified length.
The assembly includes the Hydraulic Snubber with End Attachment (bracket) and Clamp.
3.) The Maximum and Minimum strut length values are based on the strut at full adjustment and the Snubber at center stroke.
4.) The Hydraulic Snubber and Strut Assembly spring rates are based on the 4 and 6 inch stroke units.

REVISIONS
0 Original Issue 9/21/10 3

1 Revised all Spring Rates 10/1/10 4

2 5

BERGEN-POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. 1 PART NO. 2831


( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
lire GDRS CATALOG INFORMATION SHEET

IfiECHANICAT SHORT STRUT. PART NUMBER 28ffi4"

Swing Rad.

2 1/,16

11 7t16

for user application only. Premt Eouation'r


compatible with B-P Parb 1()ff), 6175, 6202, 6252, and 6280.
4.1 the maintenance manualfor installation and operation instructions. Tension = Stoke- Moveme,n!
* 5.) L=Lmin+SetPosition. 2
' 6.) P-P MlN. dimension based on the Snubber set at Zero on he scale. Compnsslon = Stoke+ Movement
2

ORDERIilO INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Kip Size Designation, Direc{ion (Compression/Tension),
Movement, the'L' dimension and Pin . Pin at the set dimension.

D$MPLE: 2860-4-R/0-9 Direction = Tension Mvmt = 1112' L = 17 5/8" P'P = 20 7E

REVTSTOf{S

/o\ Aefminary lssue 4126110


J
/i
/r\ /1\
/z\ /i
BERG EN.POWER PIPE SUPPORTS, INC. SHEEI 1 OF I REV.
A PART NO. 2860"f
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tflJ., dJ,
J
CDRS CATALOG INFORMATION SHEET
i

ITECHANICAI. SHORTSTRUT. PART NUTBER 2860.6"

Swing Rad,

I 11/16

4311116 51 15/16

for user application only. Pnget Eouation'g


'compatible witr B-P Parts '1000, 6175, 6202,6252, and 6280.
4) the maintenance manualfor installation and operation insfuctions. Tentlon = Stohq -.Movement
* 5,) L=Lmin+SetPosition. 2
. 6.) P-P MlN. dimension based on the Snubber set at Zero on fie scale. Comprerrion = Stoke +Movement
2

ORDERING INSTRUCTIONE:
Specity: Part Number, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension),
Movement, ilre "L'dimension and Pin. Pin at the set dimension,

DGITIPLE: 2860-6-R/0-g Direction = Tension Mvmt = 1112' L = 21" P-P = 24-114

AlPnliminary lssp l,/N


/l\
'f26li0 /t
A /\
BERG EN.POWER PIPE SUPPORTS, INC, SHEET 1 OF I REv. a PART ltlO. 2860'6
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
lit D' d
fl
CDRS CATALOG
'NFORIIIAT'ON
SHEET

TTECHANICAI SHORT STRUT- PART NU'TBER 2860-10"

Swlrq Rad.

111t16

11 7116

for user application only, Prcrt Equatlon'e


compatible wifi B-P Parts 1000, 6175, 6202,6252, and 6280.
4,)Ri he maintenance manualfor installation and operation instructions, Tension = Stoke- Movement
' 5.)Di L=Lmin+SetPosition. 2
- 6.) P-P MlN. dimension based on he Snubber set at Zero on ttre scale, Comprecrion = Stoke + Mowment
2

OROERING IilSTRUCTIONS:
Specify: part Numbel, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension),
Movement, he'L'dimension and Pin - Pin atthe set dimension.

D(AMpLE: Z8O&10-R/0-9 Direction = Tension Mvmt = 1 112' l= 2F112' P-P = 2S3/4'

/t\ /t
A /J

BERG EN-POWER PIPE SUPPORTS,//NC. SHEET 1 0F I Rry. A PART t{O. 2860-10


( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tir I' ?
CDRS CATALOG INFORMATION SHEET
-
MECHANICAL LONG STRUT. PART NUMEER 28704"

Part 1003
Palt 2850
1* Swing Rad.

ifrn'-*ql

M
KIP L P.FIII PI
B D E
Mtil illtlllttnr
,P o QI R T w
stzE Irrrr.. $r.

1 I 1t2 3 5/8 13t4 123t8 s 7/81 -"luul 1t2 50 45 11t4 5/8 1t2
2 1 1t2 4 144 1?3t8 ,*lllXUII/8 Ih36 5/8 1t2 50 45 11t4 5/8 1t2
3 2 5112 2 3/16 15 ri{lllNr,, 29'T "rtIl59 ffi 50 45 11t4 5/8 1t2
I 2 7t16 61/8 25t8 16 3/8'll$l'qffi0z 7/8'tt[lllr*1162 5/8
''t{l&"
314 100 120 2 718 5/8
16 3 7112 31t4 slllilil**,.- 'il 76 9/16 1 100 120 2518 1 3/8 1

25 31t2 8 3/16 3 7/8 p20 m3878 87 7t16 11t4 100 Afi 2 5/8 11t2 1

40 4 3/8 11 4 9/1ff1'r'1trhh.23 5'l 4A 1t8 1023t4 1m 100 440 3 5/8 111t16 11t4
60 5 11/16 12 5718
'{t,tfr,,112'ni , 49 3/4 107 1U4 100 440 41t8 I 13/16 1 1t4
,l00 7 7t8 14 ,illiE,1/4 3T'll 58 1/8 1241416 21t2 100 44 748 2 1/16 11t2
15{t 8 5/8 15 3/4.,rrllll} Srq!10. 350'.?/16 61 2/3 128 3t8 21t2 100 4N 7 3/8 2 1116 1112
250 11 7116 2S$lp" .*ir,1 1'"lllilir,J.,'$ll{1 3/8 723t4 154 3 100 440 I5/8 2 5/16 2
,lr. rl

NOTES:
1.)Ail tuque in foot pounds.
2.) user application only.
3.) P allow for at
2" adiustment. Preaet Eouetion's
4.) and tighted nut to the nominaltorque value (Q)br locking,
5,)This is compatible with B-P parb 1000,6175, 6202, 6252,and6280. Tension = Stoke-Movement
6.) Reler to manual for installation and operation instructions. 2
* 7,) Dimension L L min + Set Position.
= Compreeslon = Stoke + Movement

' 8.) P-P MlN. dimension based on tre Snubber set at Zero on the scab' 2

ORDERING INSTRUCTIONS:
Speciff Part Number, CDRS Revision Number, Kip Size Designation, Direction (Compressim/Tension),
Movement, the 'Ln dimension and Pin - Pin at he set dimension,

HGIIPLE: 28704-R/0-9 Direction = Tension Mvmt = 1 llt L = 17 5/8" P'P = 34'1/8'

RB/|S!ONS
/; Prel imi narv lssue 4/26/1 0 /t\
/r\
/r\
A /i
BERGEIV-POWER PIPE SUPPORTq, lNC. sHEEr 1 oF t REv. a PART NO. 2870-4
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
CDRS CATALOG INFORMATION SHEET

MECHANICAL LONG STRUT. PART NUITBER 2870.6"

Part 1ffi3 Part 2850

lth.ull
1l
KIP L P-P'rlffilho.
B D E P o Q1 R T w
stzE lilN Mtl#lfirrn r,,,,,.lllilll,,.
*qufi|ld
1 11t2 3 5/8 13t4 143t4 20'1/js, 1t2 50 45 11t4 5/8 1t2
,{ilrH$r**l/4.F{llrdo 1/8 11t4
2 1 1t2 4 1314 14314
'0&'5/8
1t2 50 45 5/8 1t2
3 2 5ffi 2 3t16 17 USrullll'. 31.Ii 1n 50 45 114 5/8 1t2

9 2 7t16 6 1/8 25t8 18314


|
85 t/4"t1[lr*ll)'66 1/E 3t4 100 120 2 7t8 5/8

16 3 71t2 31t4 ,ffiirl#.. r. S$lil/$


uri
80 1/8 I 100 120 25t8 1 3/8 1

.Iffi,*uu,rf{l$ u0
25 31t2 8 3/16 37/8 n 41 1'14 91 1114 100 2 5/8 1 112 1

40 4 318 11 4 g/16ltnlllltr,,, Z6,ql 46112 106 1/4 11t2 100 440 3 5/8 I 11/16 11t4
o'tllil$0 ql
il. 52 1/4 110 5/8 1U4 100 440 41t8 1 13/16 1114
60 5 11/.16 12 5718
100 7 7t8 14 ll,.1l4 35{ 61112 1283t8 21t2 100 MO 7 3/8 2 1/16 1ffi
150 I5/8 15 3/4,d 8i'Tlfl *7;314 64 131 ft8 21t2 100 440 7 318 2 1t16 11t2
250 11 7116 ill'' ,'dhl1 "'ll H',11/16 75 157 112 3 100 440 I 5/8 2 5/16 2
h, ,d

NOTES:
1.) All torque in foot pounds,
2.1 user application only.
3,) t
2' adiustment.
allow for a Preaet Eguatlon's
4.) and tighted nut to the nominal torque value (Q) for loc*ing
5,)This is compatible with B-P parts 1000,6175,6202, 6252,and 6280- Tension = Stoke' Movement
manual for installation and operation instructbns. 2
6.) Refer to
* 7,) Dimension L = L min + Set Position, Compretslon = Stoke +Movernent
2
' 8.) P-P MlN, dimension based on fte Snubber set at Zero on the scale.

ORIIERING IT{SI RUCTIONS :


Specify: part Number, CDRS Revision Number, Kip Size Designation, Direction (Compression/Tension),
Movement, the "L' dimenSion and Pin - Pin at he set dimension'

EXAilIPLE: 2870-6.R/0.9 Direction = Tension Mvmt = 1112' L = 21" P-P = 37-112'

BERG EN.POWER PIPE SUPPORTS,'IUC.


( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
lir *,, CDRS CATALOG INFORMATION SHEET

-
MECHANICAL LONG SIRUT. PART NUMBERaSTO-10"

Part 1003
Swing Rad.

-'uqililli

llh' .d1

ri
KIP L P-FIllllhL
B D E P 0 Q1 R T w
slzE tTtil Mll*$ttlltr ,u".'Mlilu
I 1ffi 3 5/8 13t4 18 5/16 .38,4 OSur]flS 1t2 50 45 11t4 5/8 1t2
2 1ffi 4 13t4 18 5t16 ils 7t16 1t2 50 45 11t4 5/8 1t2
3 2 5112 2 3t16 "l|Sr*/5
20 7/8xllllr, 35 S 'g['l,7/8 1t2 50 45 1t4 5/8 1t2
I 2 7t16 6 1/8 25t8 221141 8S U4"ll F1 7t16 3t4 100 120 2 718 5/8
t6 3 7112 3114 #l*flI;1,6 3fi1iil5'rr 85 7t16 1 100 120 25t8 13/8 1

25 31t2 I 3/16 3718 b 261lllfl15{i Ilti 44 4'l8 961/4 11t4 100 444 25t8 11t2 1

{0 4 3/8 11 4 9/161"'{Illrr'291fi 50 111 5/8 11t2 100 440 3 5/8 1 11/16 1114
'Str'7116"i
60 5 11/16 12 5 7/8 h 55213 116 144 100 440 41tg 1 13/16 11t4
100 7 718 14 ,{I11f,.'.1/4
3ltuil#tl 64 133 5/8 2112 100 440 7 3/8 2 1t16 1 112
1flt I5/8 15 3/4..rrl srQtg. 43n13116 69 417 137 1t4 21t2 100 440 7 3t8 2 1t16 1ffi
250 11 7t16 2oillll"' .aiir11''tlj 'n il4 78 5/8 1627t8 3 100 440 I5/8 2 5/16 2
Ir

NOTES:
1.) All torque in foot pounds.
2.) Di user application only.
3) t
allow for a 2' adjustment. Prsret Eouatont
4.1 :P and tighted nut lo the nominaltorque value (Q) for locking.
5.)This is compatible witr B-P parts 1000, 6175,6202,6252, and 6280. = Stoke- Movement
Tenslon
6,) Refer to manual for installation and operation instuctions. 2

' 7.) Dimension L = L min + Set Position, Compreoelon = Stgke t Movement


' 8.) P-P MlN. dimension based on the Snubber set at Zero on the scale. 2

ORDERIIII G IT{ST RUCTIONS:


Specify: Part Number, CDRS Revision Number, Kip Size Designation, Directbn (Compression/Tension),
nL*
Movement, the dimension and Pin - Pin at the set dimension.

DGIIPLE: 2870-10-FU0-9 Direction = Tension Mvmt = l1l2' L=26-112" P-P = 43"

REV|StONS
/o\ ffi J
n t\
A /t
BERG EN',POWER PIPE SUPPORIS, INC. SHEET 1 OF I REV,
A PART NO. 2870.10
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
UE}I I IFIEU UEsiI(iN HEP(JiI I 5UMMA]{Y
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
VARIAELE SUPPORT HANGER 31OO GE

DIRECTION OF
LOADING

,IAAX. Temperature: 350f .


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-31OOGB RO


7 a DESIGN REPORT NO.: DR.31OOGB RO
e E]
REV Rated Loads for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size c-c MAx. Condition Level A Level B Level C Level D (see Note)
1 9',-2" 196 196 196 196 196 392
2 8"6" 260 260 260 260 260 520
3 7',-11" 344 344 344 344 344 688
4 7'.-5" 458 458 458 458 458 916
5 6'.9" 610 610 610 610 610 1220
6 6',-2" 810 810 810 810 810 1620
7 5"9" 1078 1078 1078 1078 1078 2156
8 5''3" 1434 1434 1434 1434 1434 2868
9 4',-9" 1906 1906 1906 1906 1906 3812
10 5'-8" 2534 2534 2534 2534 2534 5068
11 5"0" 3770 3770 3770 3770 3770 7540
12 4',-11" 4480 44W 4480 4480 4480 8960
13 4"8" 5956 5956 5956 5956 5956 11912
14 4"3" 7380 7380 7380 7380 7380 14760
15 4"8" 10530 10530 10530 10530 10530 21060
16 6'.11" 14000 14000 14000 14000 14000 28000
17 6''4" 18620 18520 18620 18620 18620 37240
18 5''9" 24750 24750 24750 24750 24750 49500

Thg tempelaturc as specilbd is rclatsd to tho mosl sEvore loadlng condltlon and doos not take into account
the temperatjro eltect on the spring coil'
ffifis-''d-rffi'l
rquiremenb dth€ applcaue Cods. I
Materlals: The Design Report & Design Specification
N
o Plate. Load Pin & Channel: 5A-36 are in accordance with ASME Section lll,
o
o) Studs: SA-36 Subsection NF, 2004 Edition with
IIJ
f Iurnbuckle: ASTM 4-668 CL C per CC N-71 2006 Addenda and are on file at
a
o Bergen Power Pipe Supports, lnc.
J
Product Engineerlng Depanment
z
o Spring Coil Exempt (NF-1110)
(r
o CONTROLREFNO. 31OO
PART NO.
Sheet REV.
BERGEN.POWER PIPE SUPPORTS, INC. 1of1 /O\ 3100-GB
REV Certification
VARIABLE SUPPORT HANGER 31OO GB

HETGHT AT
AAAX LOAD

li
I Lc 3100-68
stzE A B c K N w z c-c MAx.
1 1t2 4 3t8 47t8 11 5/8 87t8 314 3 9'-2"
2 1t2 4 318 4 7t8 11 5/8 I7 t8 3t4 3 8'-6"
3 1t2 4 314 4 7t8 11 5/8 87t8 314 3 7',-11"
REV 4 1t2 4 314 5 5/8 11 5/8 8 7t8 314 3 7',-5"
5 1t2 5 5 5/8 11 3/8 I5/8 314 3 6'-9"
6 1t2 5 5 5/8 11 3/8 I5/8 314 3 6'-2"
7 5t8 5112 6 5/8 12 91/8 1 3 5''9"
8 5t8 5112 6 5/8 12 91/8 1 3 5'-3"
9 5/8 6112 6 5/8 12 91/8 1 3 4'-9"
10 3t4 61t2 6 5/8 15 12 1 4 5',-8"
11 314 6112 6 5/8 15 12 1 4 5t'0"
12 1 6718 I 5/8 16 127t8 1 1t2 4 4'-11"
13 1 7 118 8 5/8 161/8 127 t8 1 112 4 4'-8"
14 1 81/8 8 5/8 161t2 13 1 112 4 4'-3"
15 1114 8 7t8 8 5/8 16 3/4 13 114 'l 112 4 4'-9"
16 1114 91/8 101/8 21 17 1t4 2 7 6'-11"
17 11t2 10114 101/8 181t2 15 2 7 6t'4"
18 11t2 11 5/8 101/8 19 3/8 15 5/8 2112 7 5r-orr

NO 1. All dimensions are in inches.


2. Dimensions are orovided for user application onlv.
t-
o 3. This product is of welded construction.
Q
o,
]U
J ORDERING INSTRUCTIONS :
o
a Specify Part No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt.
J
z & Direction (Up or Down) from Cold to Hot & C'C Dim.
o
tr
o EXAMPLE: 3100-GB-R/0- 6 HL = 373#; MVT. =1l4" DOWN ; Cto C = 2"0"
ar

REV I SHEET 1 OF 2

BERG EN-POWER PIPE SUPPORTS PART


ET
H CDRS CATALOG INFORMATION SHEET DATE
31OO.GB
9t112007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

/
\
ffi \,.'
f --., ill

fl
\

3?oo-GB
I
DIRECTION OF
I]c-c_ l
LOADING

*
Temperature: 350oF
tr11AX.
Note: The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS.3lOOGB RO


DESIGN REPORT NO.: DR-31OOGB RO
Rated Loads (lbs) lor Classes 1,2,3 & MC

Itt "*T-".u*. ffi


l r,onqluo"
oPERAnNGcoNDrnoNS ffi
(.tee Nure, I
I

| 1 | g'-2"
I z I
m
| 4 |
8'-6"

7'-5"
t-t-
lgqalg++lgqqlgqqlgttloeall
lcsel45s1458 1458 1458 1916 ll
I

| 5 | 6'-9" letolsrol610l610l610l1220ll
ffi
| 7 | 5'-9"
lsrolarolSl0larolsroltezoll
L--!-

I rozs I rozs I rozs I roze I toze I ztso |


ffi
+
g |
I I
llgq I 1434
ll;gt I 1434 I 1434 I | 2868 |
|

I 4'-9" | 1e06 | 1so6 | 1e06 | 1e06 | 1e06 | 3812 | |

| 10 | 5'-8" I ,
zssq I zsgt I zsgq I 2534 | 2534 | 5068 | I

| 11 | 5'-0" | ,
3T7O | 3770 | 3r7O | 3770 | 3770 | 7540 | |

| 12 | 4'-11" | ,
4480 | 4480 | 4480 | 4480 | 4480 | 8e60 | |

I tg I 4'-8" It----.! sgse I sgse | 5e56 | 5e56 | 5e56 | 11e12 |


ffi
| ls 4'-8" | |
zgeo I zgso I zgso I zseo I zgeo I
I 10s30 tosgo 10530 10530 10530
| | | |
tlzeo |
21060
|

28000 |I
| ,

| 16 | 6'-11" I tcooo I rqooo I 14000 I 14000 I 14000 I I

| 17 | 6'-4" I rsszo I reezo I 18620 I 18620 I 18620 I 37240 | I

49500 |
|- 1g | 5'-9" I zqtso I
,
z+zso I 24750 I 24750 I
*The temperat ure as specified is related to the most severe loading condition and does not take into accounl
24750 I
'l I

the temperatut re effect on the spring coil. I

cenrry rnrs uuHD


r
"oroffi
requirements of the applicable Code.

ilaterials: The Design Report & Design Specification


t-
o )late, Load Pin & Channel: 54-36 are in accordance with ASME BPVC Section lll
o
o) Studs:5A-36 Subsection NF, 2007 Edition and are on file at
t!
lq lurnbuckle:ASTM A-668 CL C per CC N-71
a furgen Power Pipe Supports, lnc.
J
Product Engineering llepartment
z
(5 Spring Coil Exempt (NF-1110)
(r
o coNTRoLREF NO. 32OO
Sheet REV. PART NO.
BERGEN.POWER PIPE SUPPORTS, INC.
REV Certification l-of l- ,6. 3200-GB
VARIABLE SUPPORT HANGER 32OO GB

l
c-c
HETGHT AT
,IAAX LOAD

l
t
w

Fc-
i
3200-GB
SIZE A B c K N W z c-c MAx.
1 1t2 6 5/8 4718 16 5/8 129t8 3t4 3 9',-2"
2 1t2 6 5/8 47t8 16 5/8 123t8 3t4 3 8'-6"
REV 3 1t2 7 114 47t8 16 5/8 129t8 314 3 7',-11"
4 1t2 7 1t4 5 5/8 16 5/8 123t8 314 3 7'-5"
5 1t2 7 718 5 5/8 16 3/8 121t8 3t4 3 6'-9"
6 1t2 7 7t8 5 5/8 16 3/8 121t8 314 3 6',-2"
7 5/8 81t2 6 5/8 17 1t8 12 5t8 1 3 5'-9"
I 5/8 8112 6 5/8 17 1t8 12 5t8 1 3 5'-3"
I 5/8 I3t4 6 5/8 17 118 12 5t8 1 3 4'-9"
10 3t4 I314 6 5/8 197t8 15 3/8 1 4 5"8"
11 314 I3t4 6 5/8 197t8 15 3/8 I 4 5"0"
12 1 10 3/8 I5/8 20 5t8 157t8 1112 4 4',-11"
13 1 11 I5/8 207t8 161/8 1 112 4 4'-8"
14 1 12 318 8 5/8 21 1t2 16 1t2 11t2 4 4'-3"
15 11t4 13 314 I5/8 21 3t4 16 314 1 112 4 4"8"
16 11t4 13 718 10 1/8 231t2 18114 2 7 6'-11"
17 1 1t2 15 314 10 1/8 24 18 1t2 2 7 6'-4"
18 1 112 17 5t8 10 1/8 257t8 19 7t8 21t2 7 5'-9"

lO 1. All dimensions are in inches.


2. Dimensions are orovided for user application onlv.
t-
o 3. This product is of welded construction.
o
o,
l )RDERING INSTRUCTIONS :
TU

a
a Specify Pafi No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt.
J
z & Direction (Up or Down) from Gold to Hot & C'C Dim.
g
tr 3200-GB-R/0-6 HL= 373#; MVT. =114" DOWN; GtoC=2"0"
o EXAMPLE:

REV ffi
PART
Ef,
fr
B ERG EN-POWER PI PE SU PPOBTS
CDRS CATALOG INFORMATION SHEET DATE
32OO.GB
9t1t2007
CERTIFIED DESIGN REPORT SUMMARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
TAHIABLE SUPPORT HANGER 34OO GB

3400-GB DIRECTION OF
c-c LOADING

A,IAX. Temperature: 350oF *

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Gondition.

DESIGN SPEC NO.: DS.31OOGB RO


{! K DESIGN REPORT NO.: DR-31OOGB RO
REV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS TEST CONDITION
Size c-c MAx. Condition (See Note)
Level A Level B Level C Level D
1 g'.-2" 196 195 196 196 196 392
2 8'-6" 260 260 260 260 260 520
3 7',-11 344 344 344 344 344 688
4 7"5" 458 It58 458 458 458 916
5 6'-9" 610 610 610 610 610 1220
6 6'-2" 810 810 810 810 810 1620
7 5''9" 1078 1078 1078 1078 1078 2156
I 5'-3" 1434 1434 1434 1434 1434 2868
9 4''9" 1906 1906 1906 1906 1906 3812
10 5''8" 2534 253/. 2534 2534 2534 5068
11 5'-0" 3770 3770 3770 3770 3770 7540
12 4'-l1" 4480 44J,,0 4480 4480 4480 8960
13 4'-8" 5956 5956 5956 5956 5956 11912
14 4'-3" 7380 7380 7380 7380 7380 14760
15 4t'8" 10530 10530 10530 10530 10530 21060
16 6'-11 14000 1lm00 14000 14000 14000 28000
17 6''4" 18620 18620 18620 18620 18620 37240
18 5'-9" 24750 24750 24750 24750 24750 49500

*The temperature as specified is related to the most severe loading condition and does not take into accou
the temperature effect on the spring coil.
I certity this CDRS complies with the I
requirements of the applicable Code. I

Materials: The Design Report & Design Specification


t\
o Plate, Load Pin & Channel: 54-36 are in accordance with ASME Section lll,
a
o, Studs:5A-36 Subsection NF, 2004 Edition with
uJ
f Turnbuckle:ASTM A-668 CL C per CC N-71 2006 Addenda and are on file at
a
o Bergen Power Plpe Suqqorts, Inc.
J
Product Engineering DePartment
o
= Sprins Coil Exempt (NF-1 1 10)
E
o 3ONTROL REF NO. 34OO
Sheel REV. PART NO.
BERGEN.POWER PIPE SUPPORTS, INC.
REV Certilication
1of 1 /N 3400-GB
VARIABLE SUPPORT HANGER 31OO GB

i.+
I

c-c
HEIGHT AT
AAAX LOAD

/
t_
w

3400-GB
SIZE A B c K N w z c-c MAx.
1 112 11 1t2 4 718 19 7t8 137t8 3t4 3 9',-2"
2 1t2 11 1t2 47t8 197t8 13 718 314 3 8'-6"
REV 1t2 12 114 47t8 19 7t8 137t8 3t4 3 7',-11"
3
4 1t2 12 1t4 5 5/8 19 7t8 137t8 3t4 3 7'.-5"
5 1t2 13 3t4 5 5/8 19 5/8 13 5/8 314 3 6"9"
6 1t2 13 3t4 5 5/8 19 5/8 13 5/8 3t4 3 6',-2"
7 5/8 14112 6 5/8 19 7t8 137t8 1 3 5'-9"
I 5/8 141t2 6 5/8 19 718 137t8 1 3 5'-3"
I 5t8 17 6 5/8 197t8 137t8 1 3 4'-9"
10 314 17 6 5/8 227t8 16 5/8 1 4 5"8"
11 3t4 17 6 5/8 227t8 16 5/8 1 4 5"0"
12 1 18 8 5/8 24 3t8 17 7t8 1 112 4 4',-11"
13 1 18 114 8 5/8 24 3t8 17 7t8 1 1t2 4 4'-9"
14 1 20 3t4 I 5/8 241t2 18 1 112 4 4'-3"
15 11t4 23112 I 5/8 24 3t4 18 114 1 112 4 4"8"
16 1114 23 10 1/8 29 114 22 2 7 6'-11"
17 1 112 27 101/8 27 1t2 20 2 7 6'-4"
18 1 112 30 101/8 28 5t8 21 118 21t2 7 5'-9"

lO 1. All dimensions are in inches.


2. Dimensions are provided for user application onlv.
F-
o 3. This product is of welded construction.
o
d
f )RDERING INSTRUCTIONS:
lrJ

o
a Specify Part No.; CDRS Rev. No., Size & Designation. Also Operating Load (HL), Thermal Mvt.
J
z & Direction (Up or Down) from Gold to Hot & C'C Dim.
g
tr 3400-GB-R/0-O HL= 373#; MVT. =114" DOWN; CtoC=2'-0"
o EXAMPLE:

REV I SHEET 1 OF 2

BERG EN-POWER PI PE SU PPOBTS PART 34OO.GB


ET
H CDRS CATALOG INFORMATION SHEET DATE 911t2007
f.rtttttt
IOAD CAPACITY DATA SHEET
[or
NUCTEAR POWER PTANT COIAPONENT STANDARD SUPPORTS
CONSTANT SUPPORT HANGER

DIRECTION
OF
TOADING
LOAD RATING_(lh,s.)
DESIGNED BY:
Linear Analysis cl. r, 2. 3, t Mc TEMpERATURE 3 5 0* oF

OPERATING CONDITIONS
DESIGN LEVEI. A & 8 TEVEL C TEVEL D
stzE CONDITION NORMAI & UPSET EMERGENCY FAUTTED

I 130 130 130 130


clrr> L75 L75 17s 17s
2
3 235 235 235 235
4 325 32s 325 325
5 445 44s 445 445
6 600 600 500 600
7 755 755 755 755

TOTAL TRAI/EL in inches- ltA"YIMtrM RATED InAD in pounds FoR EAGI SIZE
(lhe ninimqsr load is the load for the preceeding size- Ex: the full load
for size 5 at 5" tR. is frorn 110* to lsOlt)

Loads shown permit field adjustnent of up to t 15t without exceeding allowable


stress values.
* Load rating for all components except for temperature effect on spring coil.
3lmrr colculctlonr or lod ddo lor thh producl
'^'i t,/' tft'
Molcrlolt: 5A-36, SA-307GrB wrn prdormod ln occordoncr wlth:
\
/'t SA-193GrB7 A.S*tr.E. SECTION lll -SUlSECrlON il;
3e> COllPOl{EilT SUP"OITS (dorr of lnoo 7.1.771
oad orron llb ot:
A-668CL I or F ** ,
A-108-Gr10t8** M"ERGEN-PA,ER*,N
tlt
f rJ
a/,
.t, @
(Spring coil, bearings, washers' ruW
LA CON tA. NEJt tl^atrSH t A E 0t2.6 U, S a.

-l
rinqs exempt NF-2L?I)
9R **Code Case lJ-71 coNTROt REF. NO. 4000
&l
oN EENGEN.PATERSON PIPESUPPORT CORP. SlrcEf
ro;lo /0- 4000
PATTilO.
IOAD CAPACIIY DATA 3HC3I
sttEs 1-? I?PGS al rnd th

?ae tl tEiilf IElcl|.t_ frr- (lDPloI.l


lldtgEf,
Srzl ? D G E at r I 3 t I rzr l rmronr
I
BT 1i. 2; I
i 7 t 2e tri .L
tt I sl 26 ao
l-l 21 I
aL tit 2
t
2
7 1 at rrl. tt t t
I 2l I sf l5
BI rf, z| 2
el I 2 ,t t ao
a-? I ri ri ZL I
lL ti. 2
2
I 2
E i d
'For tLr I
+ lrrr .1r.. 5 to 7
tlrrcd rrqutruntF ?' l-i. thr.d f.ottb tor rod ll'ntcr 5P'. (tll thc.dr ottlqrel co.n 12 fltl .
Fil OnDBrnt tISlGlIClSr tatlFtl 9310
PART 40oo
BENCEN+ATENSO}I PIPE SUPrcRT G(ORP.
IOAD CAPACITY DATA SHEET
for
TUGIEAN FOWER PTAT'IT COMPOiIENT STANDAND SUPPOffiI

CONSTANT SUPPORT HANGER

4000-A1 4 00 0-81 4000-c1


F 4000-Dl
400 0-Bla

!
Dnccnolt
OF
toADll{o
IOAO nAnNG flbcJ
Linear Analvsis cl. 1,2.3, tl,lc TEMpERATURE 350*-op
rr--

OPERATING CONDITIONS
OESIGN Level A & B Level C Level 0
srzE CONDMON NORTAAT t UPSET E,TAERGENCY FAUTTED

I 905 905
9 rc90 r090 NOT APPLICABLE
10 13 10 13 10
1I 1465 L465
L2 L620 L620

Tabulated loads shown are maxirnum rated values at mini-mum total t,rave I
offered for each unit size. Refer to Size Selection Table on Sheets
g & 10 for Load-Travel combinations '
Loadsshovrrperuiifieldloadadjustmen!ofuPtoJl5lwithoutexceed-
ing al.I,owable stress values.
*Load rating for all components except for temperature effect on sPring
coil.
tlrrrr crlnJrtlat tlrrr d.0.lotr{rlr 9€4lst
ffia* 3={:36 5A-!9ZE
' rrr pedmrrd h rcrldrecr wllh:
A-519 Gr 10!.8 Cl'j** A.3-r.:. Stcne{ n -3u]3tctKrr ilt
CWtDrl:flT $.FFOII3 (dci. ol lrrrr t'l'77)
A.-553 CLC & F**
--i:;!c-rT
flAtru n,a..._9tth*-

W"W
=--*,'/nonuil A-108 Gr 1014a
trl
J
(n
cn
HI
rl
(\
r-
C'\
=rffi
=,1
=S
i r"ne l,.=
iR SA-193 Gr 87 & SA-194 Gr
rino coil beari
ffiF,212!
**Code Case 1644-6
2H

Control Ref. No. 4000


CIN ATERIiC'II PIPCSUPFONT CORP.
$fir
F{ F{
& srlr le-1-17 sEP 'TR6CN+ LOTD CA'ACI'Y DA'A $ltrl ? etla
o
oEtctQ. r." I
rycD !o lrr
llLBllllctrtE

a'l $''om30 Eof


ElrElrttrrtra.a tilr T *".:ED ^EYE

aal DIrrEXSIONS in lnchcs lfi. (Aeeor.) Lbr.


c F lt t L It N s So T w Ncr 5hc.
HAI.IGERSIZE Bt G
60 75
t- tz a'-r. g/. c.L l'/, l'/. !|. 2 7'.l.

rolc.ogl ir dirnrlorr
t llcriot,r- dirronlicr. fr; t'at?-'

Dlmenciom Provl&d Fa
R
t fbcrfpilcado Only
=
x

tleld lord FOR ORDERI I.IG I NSTRUCT T ONS


tot.l tord rlruld !tr|uts rn rddltloml t5l for D6stblc
nod Selcctton-thc 'djuttllnt SEE SHEETS 9 &10
Ri:"hl?:9.:TrHlh:',rffi il,,illtl^gt th'crds mtromr corrtt fz rrt)'
PARr 4OOO
BERGEN+ATCISON PIPC SUPPORT CORP.
DAIE 8-18-8s
LOAD CAPACTTY DATA SHEET
lor
NUGI,EAT POWEN PTANT COXIPC'NET.IT $fAilDARD SUP?ONTS
CONSTANT SUPPORT HAT{GER

::

i-
FI
h*
V 4 ooo-A1
J

4 000-81
4 0 00-BIa
{000{1 4 000-Dl
!
DINCCilOl{
OF
TOADING
IOAD RAflNG flbf.)
Li,near furalvs i s cl. l, 2, 3, t lAc TEITPERATURE 35.d,OT
DESIGT{S tY:
OPERAI ING CONDITIONS
D€SIGN LevelI UPS
&ea Level c A
ra Level
FAULTED L9)
D I
srzE ccrNDlncrN NORIAAL T Eriehbixcv
18 10 1810 18 10 18l.n
13
2 000 2t00 2000
t4 2240 ?240
I5 2240 2240
247 5 247 5 z:47 5 t i?'c
16
271 0 277 0 277 s
L7 277 A
3060 30,50 r00 t)
18 3060
3400 3{,0 0 3ro0
I9 340 0
1735
3735 37,35
20 37 35
1120
2l 4729_ 4L20 4:l2O
4500 4500
22 4500 4500
495 0 4 950
23 4950 495A
r\ s4 00 5400 54m
24 5 400
t\ 59 40 594 0 59{O
I 25 5940
o
fn 26 6480 648 0 648 0 64 8I)
I
27 5 7I0 5710 5;7L 0 sTlo
N
c-l 6234 62'30 6 230
28 6230

tabulated load! shown are maximrur rated.values at minimum total travel


Table on sheetg
of,fered for eacb o"it litt'-- nefer to size seiection
;-;-10-ia; Ioac-Travel cobinationg'
IoadE shoen Per.mj.t field load adjusuBent of, up
to + t5t ttj'thout exceed-
ing atloable stress values '
*I€ad ratlng for all conPonents excePt for iemPerature effect on sPr:'ng
coil.
Slnr cdadcttcr ct t .t dcll ior lill prodrrl
wur fer{ccnrd la ecccrdncrwlltl
l3.I.1.3rctKf,l l[ -3utslcnoil ilt
A-568 CLC .9 Fthhda t:fse-til-- COillOll0ff 3lt?tO[t! (dc.. c{ lgro 7.1.77)
ndrroerlFcti
ffitrde
W
Qggg-H-Z,l
14 SA-193 Gr 87
st
glF
Sorinq coil beariogS, washers
Hf-
Ci \o
HI
Et-
I
,# t:noal.PArER3oH PIP:SUPFOS| COIP.
control Ref. llo. -
3HEf
4000
PAtt llct.
o l.Ar z / a/z tlltlll
to^Dclt crroltA ?- or lo 4000
#s
J

Lb
ioo tArE-out

Prodrct of wscd
Cmr&rc{on
ITiFtsT
orefiqr
gaD lo raY I
lrr
aalrialggtlnll
I

Er
Hlrt{It

FE6cl fwFpr-llmvt
ttE Jttort[o G,il ?p€ SlttorrtD
IrrnE'|rr I l' llrt: I

Dilt -lii- (A-.or-l I hr.


Al t Blo lftf
HAIGER SIZE ffi ]ti
v, l3l
Slrorg.
150
13. a 5V,
It.a CV, 5t/t Itt lt/, 14 t/, ,ta ta
l8 200
tt

81, cl
ADI HGR. SIZE

up lrovrl, dirnonrlonr rhorn lhould


t tlorarun dknorler lor 7anP. ---
noo olereten tnt
2t-
Dlrebo ProvldFor
13. 16 11.79 ol'

rt/.-(tat2le,
-(&3 rnl t7.-(2 Tn)
|,/.-lla.t?
l6-tz-''ArRl
I tbcr APD[cado otttY
,r 4t4.t rRl -(.{!4 rRt
.a TRI 7.-(7.12 TO FOR ORDERTNG INSTRUCTIONS
SEE SHEETS
.9 E I,O

BEROI}I+ATTTSO}I PIPI 3I.IPPogT GOTP.


DATE 8-2T-C2
LOAD CAPACITY DATA SHEET
lor
M,CI.EAT PC'WET PtAffi COTIPONENT STAIIIDARD SI.l?PONns

CONSTANT SUPPORT HANGER

F
4000-c1

!
4000-A1 4000-81 4000-D1
400 0-Bla

DnEcrroN
o;
tOADlllG
roeo nenxc nu.t
__j

DESIGNED BY: Linear Analvsis cl. l. 2, 3, & MC TETAPERATSP 350*oP


OPERATING CONDITIONS
oeircN Level A & B Level C Level D

srzE coNofnof{ NORr,lAt I UPSET EMERGENCT FAUTTED

29 684 5 684 5 z z
30 7 645 7645 r# -i -
31 8650 86 50 E
-9 rlt
32 9{80 9480 F
33 10515 r05 15 H l-{

117 00 I17 00 c)
34 \-
f\ 35 107 00 107 00 r
ru
F
a: t 36 11750 11750 L.l

c3 o
I (Vt
(\t
ac
I abulated loads Shown are rnaximum rated values at minimrrn total travel
offered for each unit size. Refer 'r-o Si-ze Selection Table on Sheets
@ F{

9 & 10 for Load-Travel cornbinations.


Loads shown pernit field load adjustrnent of up to I lst without exceed-
ing allowable stress values-
iLoad rating for all comPonents except for temperature eifect on spring
i]. .

o
L
$il crlrrdc{or oe tret a.t lc" thh pcArcl
rre fdcmd h rcordlrcr ;llh:
A-519 611018 C!{** A.s.*L 3GItO?a n -$Ngrctrtil ilt
A-668 CLC & F** COpOilttff 3lJt?OfG (dob ol hnr 7'l'74)
sndrrcllilrct-
r 1018**
tr SA-193 Gr 87
('Jr\ Sori nq coi 1 beari nQs J{alh€r!
vtt
t{ rt s exempt i{F,
rr{ **Code Case 1644-6 ontrol Ref. No. - 4000
ol
l'.t o
&,d BINCT*PATERSON PIPESUPFOffi CORP.
o to^ocltrclw Dlll $ltt?
i-R
#,Tr I I
G w
I
ol

t@
Prcdrct ot wdftd
lEregil Cotrrmcton

%
+Ci ffi! oncln ral I

tffiT InlD ro rtt


rttlf,L^?.|.o.'mw

Er [trfli
''-..-H
ITffiI
*T3-
Ll I

I TDI
tll'lrcr
E? IN
it
rim
turtomfe
EEnFttElrry.!
Gfl
tl;ltl
h-r:=fypEpr I
tFE grprofircD rtorf.

; Rca-riil.cor li-trot ilin rrrvrl (ccld rc rhoold 5o iocreorod by cclucl lrcvrl dhcaricrrr.
t lfurtrrn dirroria lc reqrr..

. .Bl, cl DlrfFXSlO}lS lr lnchrr l!-Gep-:erJut.


eDl lrcn. stzE tt c D F H t T x 3 3o 3L T U Y U llrt I 3$-
29-tf, )L a T 7 lrr JA */. lrl, r% t!A x ltA I t2i.a 3t0 3.0
no'o DtAnETET__(n Dt-;L* Prrovtdcd For
29 -3f2 3l .36
t'4-0'#3 TRI r16-t2'+r rnl ()rrtY
t7.-(rr&s rnl rU-{3,t,-.UTRI tbcr Appficafrm
| -(5%16 rRl t%-tS-Z'{ rnt
I -.r-ra tRl FOR ORDERING INSTRUCTIONS
noc setdiitor.-tiii tout to.a grotd i*rucr.i tiitrdilITst tor p:rlbtc rlcld lord dJul*rt
urd th. nlght of thr urrlt for type Al only'
SEESHEETSg&10
iiiiit-nii i il'riiti- id' i. r. u'iii rinitrr' irlt tt'@
-

PARr 4OOO
BERGEN+ATTIR'I'Oil PIPE 3U PFORT GORP.
DATE 8- 1.8-83
TOAD CAPACITY DATA SHEET
lor
lflr€tEAt POWEn H.Affi comP{oNENT STANOARD SUPPOnnS

CONSTANT SUPPORT HANGER

4000-Al 4000-81
4 000-BIa
El
Io
#.Jil
?
-
4ooo-cL
i
F 4000-DI
!
DINECNON
OF
tOADIilG
LOAD RAnNG
(lbr.l
l,2,3,&lc 350*oP
Oe16NEgy, Linear Analvsis cl. TEMPERATURE

OPERATING CONDITIONS
DESIGN Level A Leve I B Level C

NORAAAT & UPSET EMERGENCT FAUTTED


srzE CONDMON
37 1305 5 13055
4 3s0 IItJfU z
o zo
38
i5-eE'5 H ra
39 1598s
40 t7615 ffi }'
tt
E
vU
E
4l l9 10 19 3ro r{
21000 H H
42 (1
v@ o
43 22L80 22L80 }'td
44 24000 24000 F rl
trl H
rl I 45 21700
46 23250 21250
-
Eabulated loads shown are maxlnqa rated-values at llinlmum total tf,avel
;E;;Al";-"icr, ,roit Refer ro size selection rable on sheets
t-e-10 for r.ad-Travel"i"..
coobinations '
IoadssbownperritfleldloadadjustmentofuPtoll5twithoutexceed-
ing allowable stress
values '
*tpadratingforallcouPonentsexceptfortenPeratureeffectonspring
coil.
$rrr. cdcrdcdcm ct t d ddc 0cr thlr fc*rcr
ffi;'-A-35, SA:!02-Gr-E rer prdonnrd ln rcccdcocr wllh:
A-519 Gr AS.n"a, $cnoil lll .3ulsfctpil NF
C0mtOilfl|| 3rt''tOlll! (dob o{ rre7'r'77)
-Ir> r* A-668 CLC & F** and crr on llh c$

?-t

o
-I
+{ Sorinq coil bearings' washers
BENGEN.PATEN.SON
c1o'ptilUlfpx
"'plarD"ull
LACOTTA Aat H tranrra otraJ' u t ..
Q
t{ f\
rl
t\ rreode Case 1644-6 conEof Ref . No. - 4oo0
3llEf ?AlTllo.
Ci tn ITROEH-PAIIRSOil PIPCSUPPOffi COIP' 4000
xr
HF{
Oo ilAr a / n/n tct ocltactrtoAtA$trr 5. or 1o
P roduc s truc
rhs
J

Prodrct ol W€lded
fT/-YPElil Cornrucffn
l-wr-FBil
tv1r ffiIU
grE llt TAV I

t :1 Irr
lllttt.l. rnmtB

t
l
P

cl
or

frvp-E-l
lEt-trqr
lrt aarrf, r
t@t
ttc $ttqTfo ctor tTffii-l
ltrrlE?t.irlr aa r''tt rpc lt.?roi?ED r.Orf

in lnchrr

qr Rod tsko.ooiir for lorr llovr rg trovol dirnrnrioar rhown r lacroorod by octuc! trcvrl dirnenlicor.
? llorirnu- dlmrnriqr lor grcuP. , Dldor Pnovld For
to ' Ulcr App[cailo Onty
ROD D1A. (Rl tv rrt ua z 2rA
FOR ORDERING
8.000 I I .630 l s.700 20.700 27 200
LOAD.
flcld lord rdJushnt
INSTRUCTIONS SEE
S.t*tt--th. totll lord rhorrtd 'lacludl rn rddltlon'l l5t for Porrlblc
SHEETS I t 10
noa
lltlr*l*&l.l5ry*rirffi flSllti^tt rhrurdc nrHoarr co*rc 12 flt).

ltlcllrl+AttrSOll Pf PC IUP|rOIT (gE)l?'


LOAD CAPACITY DATA SHEET
lor
ilt CtEAn POWET P[Arr comPoNErf sfAl{DARD SlrP?Orrs
CONSTANT SUPPORT HANGER

4 000-A1 4 000-81
tl000-Bla
ffiF! D|ICCTION
OF
LOADIl.G
LOAO RAIING (lbr.)
Linear ir-nalvsis ct. l,2,3,tlc TETTAPERATURE 350* oP'
OPERATING CONDITIONS
Le'vel A & B Level 0
NORAAA! t UPSET FAUTTED

22325 -22325
zo zo
-l rJ

3059C 'tt rtr


33065 33065 -
F
l-l
rT'
l-{
(') c)
387 35 387 35
@ tt
F F
rfl fil
5O | 44I
57 I AZrS
50250
5J250
53700 53700
54000

tabulated loads shsrgn are naxirirum rated. valueg at minimun total travel
;E;;;1";-eictr-"nii gi.ze. Refer to slze selection Table on sheets
i r fO for Load-Tlavel conblnations '
toads shown perurit field load adjustment of uP to t Lst without exceed-
ing allowable stress values ' ..

*Load rating for all conPonents except for temperature effect on sPring
coil. 3lnrr cdculCtocr ct ffi dorc lor rhh p.oduct
morrrtolr: 5A-36 ' SA-307 GI-q rarl ;.rfotild la ccccedcm drh:
A-519 Gr 10 A.3.tI. 3lcnoil lll - Surstcnora flt
@PCtilGtlT Slr?iCttl! (d.r. oa irrrr 7.1.7?)
A-668 CLC & Fffi ori crqrf,lo cr:-
Gr 1018**
ld SA-193 Gr 87
Dr\
rn.t\ sori ne coi 1 beari ngs--t1e5-hg-fs
gtt tza r^J2tHtte ct2ae.u t
^
HO
14 **Code Case L6,U-6 Control Ref. No.
ur
HSI
C,A lEtonr+ ArEn3Ctt{ PlPt3UPPCtn conP-
o 3rlr 1L- 3c- i1 sop LOTO CA'ACII' DAIA 3TCt?
l iOO
El
tlrC.Olrt

Rrodrt ot Wdded
Ccffitry FTFF6II
r-A ,

Er
attE-'

lfr"E st"l
lEarrctrylt ti
g.ari! f
rtxllffo lr-qr
'pa
FlEFlr'FltE.l litf I
efoduqt of Welded Constructien.

I
c
n

:[lcrirnn dlrcarigr l* go,og.


tt- (Aooror.l Lbr.
Bl, cl Net I Shoo.
&DI HGR. SIZE
rs I r% It --'#
l2s0 I 1300
|/-fu
sr-60 7 t* clrt tzv. t/. t0 7 tX t'{ TA %l tn 1610 I rrao

eSX_ 0 to 60 | Icads exceeding max


ROD DIA. (Rl tlt tx 2 2\ 2h
specified reguire
non-standard rod
LOAD. I t -630 r5-700 20.700 27,200 33..00 connectiong.
'inoc
l;J s"t*ttoo-thc totri toU rtroold lrcluda ur rddltloael l5l for postuic flrld lord ffultnnt-
ih;;iirit or thc-ittia-tb; @ g orlr. . .r, FOR ORDERING INSTRUCTTONS
iffi;in&;iiifrti-Ie;'i.r.-irril'i-.tq'dt''trtt :h'._d:_yjtg] Tf. l.111!,: SEE SHEETS & IO e

BINGIil+ATTTSO}I PIPE SUPP'OTT GOTP.


8-1 8-83
IOAD CAPACITY DATA SHEET
lor
NUCI."EAR PC'WER PTANT COTiFONCiIT STAI.IOARD SUPPORNS

CONSTANT SUPPORT SIZE SELECTION TABLE

f tr..drti (!! uarlr o'c'isblr rr rrrr 16'


i 6;;;;"';i"i esv .tt" il9 unrrr rglrci tc tcgrotica lrcr rcbl''

Orderinq Instructions :
Specify-Part No., TyPe, Load Capacity_Data sheet
niv, N6. , Size Designation, l{ark No - Operating
Load, Total Travel, Thermal Mvt., and Directicn
+Tq. !-8 C to H, Dia. and l4aterial of Supporting Rod (C-S-
or H.s. ) .
Example: 4000-BL-R/1-9, rYk. RHH-7, O.L. 620*'
T . T . 3-J-/ 2" !{VT .2-L/2 " UP , Rod Dia -
5/8', C.S, '
r"?
IENGTN.PATERSON PI PESUPPC'ffi CORP.
I
7/6/ta tolo Grtlctrr oAlA SHln
Fildr#c
TOAD CAPACITY DATA SHEET
lor
NUCTEAR POWCN PTANT COTiFONENT STANDATD SUP?ORTS

CONSTANT SUPP-ORT S I.ZE SELECT I ON CHART


- F.r Tln lc:ll l-l tanolt.ir. l0.t l0'tf.i

NOTE: Carrrcrt SsPeorrl


rhcold br rllocted ritt rgffi.
cnr-t?avd lc ingrc cn
Giaatt
odrqrrrr lrcvd lrrrrrr tfisr
providiq tor ony porribb
dircrgctcy betrrr rhoc'
reiiccl qrd ccruol pipial
moYata'lr.

ordering Instructions :
iil;i;y'eii[ -No. , tttpe , LoadMark
Capacity _Data Sheet
nlV. N6., Slze Desiination, Mvt. No. Operati+g
Dj'rection
I and
il;a,- Total Travel, Thermalof Supporting
<,rL Pt.t -a E-t"'ff, Dia. and, llaterial Roq (C.S.
or H.S.).
Example; 4OO0-BL-R/1-9, !4k. RHH-7 r O.L. 620* '
t.T. 3-I/2", !{\t\t.2-L/2" UP, Rod Dia'
5/8u C . S.
SEnGE'|+ATEnSON PIPCSUPPTORT CORP.
,.Ar llCllt $om tolD cltActll ortA 3Httr
frtli
TOAD CAPACITY DATA SHEET

NUCTEAR POWER PLANT COTAPONENT STANDARD SUPPOTTS

TC-4 CONNECTION

++ !
DTR ECTION
OF
ro ADING
LO,{D RATING (lbs.)
350
DE5IGNED gy. Linear AnalYsis
op
ct. l. 2, 3, & MC TEMPERATURE

OPERATINGCONDITIONS
o€stcN LEVEL A& B LEVEL C LEVEL D

CONDITION NORMAL & UPSET EMERGENCY FAULTED


..'l 'l
t'.1'.i'.r
'i

755 755 1000 l4 l0


L lt)
1520 t5 20 210 0 3040
5480 5480 8500
11760 11760 155 00 2210 0

5 240 00 24 000 32000 4sI20


6 57 2AO 572 7 62A0 I07530
7 75000 75000 100000 14I000
I 87500 87500 115 500 154500

Slrur coiculctlom or lorl ddo lor thh product


wrc potiorrned ln cccordonct wilh:
As-S-E- SECTIOX lll - SUtlSECTlOll Hf
.A '/1. \
z3z {dorr ol lruo 7.1---l
oLZ
uz'.
HAROLD lnt'-
I:OF.TEN JR.
{ Nc. i36 l7 =
fr.o t
,4.
oD r\ ,v{
HI l",rtr4 .svs 9-\
'.-\
--- LAcoHta
^t€frhaAttsxtnL
oJ2a5 (/ s

.;N
cn
11{A
S
..\\- Ccnt=ol Ref. No. 4004
Hl
oi cl
IKT.
1il1
rtnceN-PATEnsox PlPEsuPPoRr coRP.l SHCET PAm xo.
O Fi L \--rf
J to rcr{@ |
I
rolD c^r?lclTv Drtl 3Hrrt I
rorl 4004
A -|l-i
!

I
T?
4-C+D I f

--r
I

+l)
B

vI
L-s-I{OLE l-
-T
F

r-H.LE

H J
SIZEI HANGER SIZE A B C D F HOLE HOLE T S

2i 2L
1 lcsH l-ToT 4+ n n 3 3
I
3
)L_
I
2 1 "2 T B G
2L
2 1 CSH 8 rol2 5 2 1 3
3
T
2T
T T
3
8-
3
16
29 29
3 I CSH L3 ro28 r2trl 3 1l 3 1+ T n 3
T
1
T
o .It- I
4 lCSH29 ro 36i 7 3
I

4 Li 4 1i I-
L32 l-32 T T
rl ,q 5
5 I csH 37 ro45i loi )z 3+ 5 2+ 1u"
-L32 1+ L 16-

6 jcsH 47 rosotrz+ or j+ ^L7 1r


L32
3
o2 5 5 L32 * 8-

.9 I
7 I (,SH 6C ro54 14+ o3
c4 5 8
,3_
)4
n25
.' ') ')
-)/- !32 2 z
I
.E
,L7 lc
8 | csH 55 ro58 L5+ o3
OT 5 I z3
)T
11
L32
LJ
t-
L32
fiiJ
ll
!-g

ONDERING INSTP.UCTIONS :

Specify Part }lo., Load CaPacitY Data Sheet Revrsron No. r ano
Size Designation-
Example: Part 4004 R/ 2-4

PART 4OO 4
BERGEN-PATERSON PIPE SUPPORT CORP.
DATE s / 3/ s4
F n !t-xf 6

LOAD CAPACITY DATA SHEET


for
NUCTEAR POWER PLANT COMPONENT STANDARD SUPPORTS

TC-7 CONNECT I ON

DIRECTION
I

OF
LOADING
LOAD R6TING_(lbs.')
DESIGNED BY: Linear Analvsis cl. 1.2.3.&MC TEMPERATURE
350 oF

OPERATING CONDITIONS
DESIGN LEVEL A & B LEVEL C LEVEL D
CONDITION NORMAT 8 UPSET EMERGENCY FAUTTED

1620 210 0 3040


6480 5480 8600 i218 0
1175 0 1r750 15500 22!0 0
4'24ooolz4oooi32ooo'45120
5720A 37200 7 6200 107530
75000 750 i41000
87500 875 56 154500
t-.
r-.
I

ca
I
I c-'l

Strerr cqlculoiionr or lert dato for ihlr product


wcrc pcrlormcd in sccordonce wilh:
& Bar 5A-36
.i!;ntiz
A.S.M.E. SECTION m . SUESECnON NF
COAAPONENT SUPPORTS (dorc of isruc 7't'i7)

1m
ond ore on lile ot:
-- ,/ ,; \ r: i,l l t-e- ';'
=.
| ; ,- ri., jF: fr= i-
tEl -
r-l | L4J gJ BERGEA-PA.TERSAN
=,^ =: fr P IP E S U PPORf C-ON PORA| OH

i-; rl LACOPta Ne wHaJaSHtnt '


OtZttE U S A-

fn
I Control. Re f. No . 40A7
9r
./ (N BERGEN.PATERSON PIPESUPPORT CORP. sHEEr I RF^v' I renr Ho.
C-r sEAt i?-?3'i6 siorreo roAD cAPActrY DATA SHEET I l- oF I Al 4oo7
rz1 =

i lrr
I

I
!

' H.HOLI

H
HANGER A B D S
SIZE SIZE HOLE
3 2L J 3l
11 112 7 ? T T 6' 16 I

29 I
2 13 28 3 3 1+ T T
3
T
q 3 I
3 29 36 4 4 1? L32 T T

37 116 I sl (r ,r t#l r 5

,w
4 )2 L2 fe

5 r+7 60 i sl q ;
t2
J
6-
!)

; 61 64 is? 10
-)L z$l z
1
7
t, s* c25l
L32 | tt- g
5

-
*DO NoT usE oN csv 65 58
-
ORDERING INSTRUCTIONS:
specify Part No. , Load capacity Data sheet 3ev.
No,, and S:-ze Designation.
Example: Part 4007 9.i 2'4

BERGEN.PATERSON PIPE SUPPORT CORP.


I eanr 4oo7
loare s/:/st
LOAD CAPACITY DATA SHEET
lor
NUCLEAR POWER PTANT COMPONENT STANDARD SUPPORTS

CONSTATIT SUPPOI?T HA|\IG ER


6l

I-,n"d
t=E
ii'
4I0O-LBI
4I00-LBla
DIRECTION
of
LOAOING
LOAO RATING (lbs-)
DESIGNED BY: Linear AnaL',zs'i s cl. r. 2. 3. 8 Mc TEMpERATURE 350* op
OPERATINGCONDITIONS
Levei A & 3 Level i
C Leve'l D

srzE NORMAI. & UPSET i


EM€RGENCY FAULTED

l-090
NOT ;\PPLICABLE

':abulated. ioads shown are :naxi.:num rated vai-ues at ninirer:::l total i.ravel
offer:c :cr each u!:it si=e. Refer to Size Selection Tabie on Sbeets
g&9 :or Lcad-T=3"el ccnbj.nalicns.
loai,s s ho'*6 per#.t ilei.d load ac.y: us-;nent oi sp to + t5* 'tithout exceed-
ing altowable str3ss l'a1';es.
iLoaC 33t:::g f or aJ,1 ccmi:cnents esce9t f o iernPera--u:e ei:ect on s!:rr ng .
Ln

L
ccr-1 -
1J
o. lort dcto for fill prorirrct
Slrrr colcrrlatlor
Moteriok: 5A-36, 5A-307 G,-
won grr{omrrd in occordcncr wiit:
A-519 Gr 10i8 Chl** AsJ,r.a SECnON m . SUgSEg;rOll ilF
IlI> i A-668 CLC & F** COmFOilEilt SLr?PCtt.llt (dcl. of irrre 7.f.77)
gnd crronfile sl:
i ,4.-1:8 Gr lo!.8**

ij: r-
U]r-
HI ri ncs exesi.'lt ilF , 2!2!
ri
(n
t'4gr,ll'il,l i **Ccde Case 1644-6
ijl N *'t"
iBERGEN+ATERSON PTPESUPPIORT CORP-| ., t-/;
3 sEAr. I L-q'11 scilto itoAocAPAclr?DArlsHEt?lIorv."
.B
rls r;1iF

J,ffi
tAxE<lrT I

_j;
ffi
5Y- coxN Ecr oN

*Same as LBl except top tus rotated. e0 desree.q-,. tt"g**[ffi"d


Product of Welded Construction

,ld bc increoscd bY ocruol trovcl dimen3ion-


.Turnb.cklc ond bolr not iurnished with rhcsc gnits; connccling rod lo bc furnishcd wirh lull ond holf nut lor 5Y'Contccr,ott-

LAI & LBI NS in lnc

f Mor. dirncarioa lor 9roup.

R D

t/ta

rn roditional 15! for oo3sible


ficld load adiusuent
-RooSelec:ion-the ictal loed shosid ineludc
iii ii"-r"isht of thc uait ror t:/pelAl qnlr:--.
rhr:ro Requirem"nts'iZ; q.x.'.nriro lenqttr (Ai'i :hretds nrtional coarse J2 frt).

Dimensions Provided For


User APPlication OntY

FOR ORDEF.ING INSTRUCTIONS


SEESHEETSB&9
PARr 4tOO
BERGEN.PATERSON PIPE SUPFORT CORP.
DATE 8-1e-83
LOAO CAPACITY DATA SHEET
for
NUCLE.AR POWER PTANT COMPONENT STANDARD SUPPORTS

CONSTANT SUPPORT HAN GE R


n o

DIRECTION
OF
410 o_r.Ar
i lB B:lBi" LOADING
(lbs.)
U?AD RATING
DESIGNED BY: Linear AnaI'rs!s ct. 1.2,3.&MC IEMpERATURE 350*oe
OPERATING CONDITIONS
DESIGN Levei A & I Levei C Level D

CONDITICN NORMAT I UPSET EMERGENCY FAULTED


lqln 18 L0

7 !
2
_' -; I

3400
L
-1 I

- a) ,I
!
I

't -- c
!
c-l
i/
i 23 4950 i- I
l
I i
cC'
,c\ ?'1 l
I :l -.- t
I

i': zt
,s

Tabulatei, ioads shorrtn are naximr:$ rated vai-ues at !::i :riaricl lctal trave l
offeraci io! eacn unii size. Refer to size selecticn Table on sheets
I & 9 for Load-T:a"'el combinatlous -
Load€ shor,{n permit f ielC loa<i ad justment o l- uo to + 15 a wi--hout exceed-
ing allowable stress values.
*Loai, rating all- components except iot temperature eii3C-r- oI1 sprir.g
cci'l .
Stlrr calculntion! or lrrt doro {or rhir pro<iucr
ilvlolrriob: SA-35. SA,-3Cj 3rBi
t wero periomrrd in occotdcncr wilh:
A.s-U.E. SECTION ilr - SUSSECnON Nf
-668 qLC, t,.f** COr,l?Of{CnT SUP?Of,f:S (dctr of iruo 7.1- ?7)
w ;,1
ffi8**
i

i
cnd orc on file ot:

SA-193 Gr B7 I

BEEGEN-PATERSON
'J: t-- , (sorino coii beann(rs, washet"s AzeauaFoe, cot^ntltox
'n r\ ffiqs e.te:not i'lF, 2\2i
1 fidA- Contrcl 3.e=. .100t
8ERGEN-PATERSON PIPESUPPORT CORP.I -
t"t- i
sEAr. ? / S/ZZ srcucD i
lolo GAPAC'IY DAIA SH:EI i 2 o, .9 i
l-Mr {,is rifF
l+l 'ri,
_T
Eo
lll€-qJY
ffi
I

A
tr^L..-=
.'H +
fr
rq'ii
S Y - coHN ECTI oN

* Sarne as LBI except toP lug rotated 9 0 declrees .

Product of Welded Construction. Product of Welded


Comtrustion

ffio".l(cotarohol|;foruptrovcl,dimcnrion:rhornrhogldbcincrcorcdbyocruollrovcldimenrion.
tTurnbuckle ond boir not furnichcd with thcrc unitr; connccling rod to be furnirhcd wirh full cnd holf nur for SY.Connccraon.

LAI & LBI in lnche

t Mor. dimcnrion f or group.

ROD DIAMETER (R) Dimensions Provided For


l3 l6 17.20 21 -21 25-28
It/,-tlV.tz
-{2-3 TR) l TR) I z-{2-31i rR) User Application Onty
ttla tat r"i-{2
-(2%-4 TR)
r,i-{l7rtz rR}
r -(l-o7r tR)
'l-lt-t2 TR)

Rod Selection-thc total lo.d should include an addit'lonel l5t for possible field load edjustmnt
and the ieight ot the unit for typerAl only.
Thread Reguireoents-12.'R.H. thread length (A]l threads national coarse rZ fit).

FOR ORDER I NG I NSTRUCT I ONS

SEE SHEETS 8 &9


PART 4IOO
BERGEN.PATERSON PIPE SUPPORT CORP.
DATE R-1R-R.r
LOAD CAPACITY DATA SHEET
for
NUCLEAR POWER PTANT COMPONENT STANDARD SUPPORTS

CONSTANT SUPPORT HANGER


n

-l-....1_.{
G
[-]f
t_l
410 0-I"A t 4 100-LBl
410 0-LBIa
DIRECTION
OF
LOADING

ine a r Ana '1.


is @ 350* oP
DESIGNED 8Y: i, '.zS ct. l, 2, 3, & Mc TEJVIpERATURE

OPERATING CONDITIONS
OESIGN Levei A & B Level Levei
C D

SIZE CONDITION NORMAL & UPSET EiAERGENCY FAUTTED


> >
6E 45 I

30 7645 7545 F;
r.l I

3t 8550 8650
I
32 9480 94
- i-
?? 10515 r0515 H i

Tabuf,ated loads shown are maxi:rum rated values at iiininum total travei
for each unit size. Refer to Size Selecticn TabLe on sheets
"fi"""a
gg9 icr ioaci-T:avel combj'nations '
Loads shown ;enit f iei-d Load adjustlen: oi up to + 153 eithout esceed-
ing allowabie stress values .
*Load rati-ng icr ali ccnponents excEpt for temperatrire ei:ect on sPrlngf
coii -

Slrar colcslstlonr or ttrt dcto lor thlr product


I Matrrislr: S}.- -16 , -cA- woc prr{ornrrd in occotdorrcr wiltr:
A-5i9 Gr i'li3 C:'l** A.SJrr.E- SECflON lll - SUSSECltOttl xF

i A-559 ctc ! F**


COTIPONCNT SUPPOf,nS (dcre oi krue 7.1.7? )
qad srr on lib ot:
tA-108 Gr lflS**
i SA-19 3 Gr
EERGEN-?ATERSON
(s3r:-rls ecil beerli ,DEsurFntcorrn ron
in r\ ffie:cenrct lF, 2L2L\
F-r r\
I
**Ccde Case 1644-5 lContrcl P.er. No. - 4000
o r<t sHEgf I ^:i PAIT NO.
U-i I ggncgN+ATERSoN PIPESUPPoET coRP-
h-.
p.e I sEAr tC/t4h7 srcnEo I toro cAPActrY DATA sHCEI 2"'i Lori-l di00
,i
'll
.;:t '
r ?F{
h.o
-a
*-
Z- ?^rtaltf
t{
r'l

5Y- coxN Ecrl oN

*Same as LBl excePt top lug rotated 90 degrees.


Product of Welded Construction- Product of Welded
Consfrusticn

LAI & LBI


HANGER SIZE
i-2,,..i Z .t r;___'l,rfu.,, 11S?, its lts nq4 tatAlt4 llr
rc tr8% ltSi
29 to 36
'Rod toke.our rs lor imcn:ionr rhown shol e increorco by ocruoi lrovcl drmen!rort.
t Turnbtrckle ond bolr nor lurnishcd wirh thcse unils; connccling rod to bc furaishcd with lull ond holf nut {or SY-Connccrion.

LAI & LBI

ROD DIAftTETER (R

possible rield !ord rdjustmnt


f,oo ieiectron-the tatal loro snouid 'inciudc atr addition.a l5Z for
anc :lre weight cf ihe unit 'cr :yoctJl oniy:.. rA frtl.
iiitrJa-niquirenents-12" R.H. thra.o lengtn (All !hret63 nttional colrsr

Dimensions Provided For


User Application OntY
FOR ORDERING INSTRUCT IONS
SEE SHEETS B &9

PART 4ICO
BERGEN.PATERSON PIPE SUPPORT CORP.
DATE B-18-83
LOAD C.APACITY DATA SHEET
for
NUCTEAR POWER PTANT COMPONENT STANDARD SUPPOTTS

CONSTANT SUPPORT HANGER

4l0c-LA1 4100-LB1
4100-LB1a DIRECTION
OF
LOADING
Lo@
DESIGNED 8Y: Linear Anal'zsis cl. 1,2,3, &MC TEMPERATURE
350*OF

PERATING ONDITIONS
OESIGN LEVEL A&B LEVEL C LEVEL D

coNolTloN NORMAL & UPSET EiAERGENC/ FAUTTED


':l<l<
13053 r_3055 I

14350 l_4350 ry z I

o o
Fi
15985 15985 Fl I

r7515 FO

-l
Fd
310
19 \t
rH
FO

21000 F I
H
o o i

{,
F
EI
I

t -t

Tabuiatec loads shown are maxi:nun rateo vaL':es atr' ninirnun total trave-l-
offereo for each unit size. Refer to Size Sel-ection Tabie on Sheecs
8&gforLoao-Travel cornbinaticns
+ 15t *ithout exceed-
Loads shown pernit fieiC load adj ustment of u! tc
rng allcwable st:ess r,'aJ-ues.
*Load r3ti:ig :cr aiJ. ccnFonenEs except for t3srperature eii=ct on spri::g
coil.
Slrrr colculotlorr ot l.lt deto lor rhir producr
Motrriolrr Sri-35. SA-307 Cr 3 wore prrforrned in qccordoncr wilh:
!!?r,-'' A.Sl .€- SECITON il. SUUTECTTON NF
COIIPIONENT SUP?Of,nS (dctr o{ lrrre 7-l-ll )
snri cre on {ih ct:
HAROTD ,A- i 08 Gl. 1',1 lEl- - .l

,J; i,Odill J3 :SA.-i93


lr'-
Cr 3; i
BERGEN-PATERSON
r^
tu Fs..." l ( Scr :no cc'i l , bearings ,washers
' :

(J,lc-
HT\ i ri ncs exenDt l,lF-2i21
Uot
I
l**Code Case 1644-6 Conc=ci Ref. No. - 4t-rC0
Hl PAf,I NO.
<o\ i eenoeN+ATERSoN PIPESUPPoRT coRP.
7/77 srGNGO .olocAPAClTl oltA sHtET 1100
|
rls r;irbF

J,-ffi
TAx€-d.tT
o
A

ffi
ITYPE LBr"l *
IIYPE LBrl S Y . cOxN EcTI oN
-_l
Product of Welded
Product of Welded Construction. Constnrctbn
* Same as LBI except top lug rotated 9 0 degrees .
LAI & LBI Torl L TRAvEL in loche s
HANGER SIZE DIM. ? 2l\ 4 4, 5 A 6\ I 9% t0 t014t I I I 12 t4 I5 l6
'Es a. 3it: Jtj 3'/f 116!t 16i l6 l6 l5'( l5'4 l5 l5 I d": l4 l4 l4 lt3 r3 13 I 2';l't 2 ll ll
9. 8t!r' 22 22 21'/, 2'l 2l 2l 20'i, 20'i 20 20 t 9'i I9"119 t9 r8 l8
t7 l7 I6",
'Eb 9Vr' 9',/r'
K f1, q/. v' 9'/t l0:" ld, ll 1l ll I t?l l3'l r3 I d'.. 1 4"" l5 l5 l5
17", l8 t8'
16t./, l9t"
37 to 4l a I a/. I l'4 I I I I I I 2"il 2", It
Rod toxc-our rs i"t oo-" r.oici (cold ro hot); lor up trovai. dimcorronr:hown 3lloshould be iocrcosco
iocrcosco by ctuoi trcvei oimensron
t Tsrnbucklc ond bolr nor l,.rrnirhcd wirh tharc uaits; connccting rod to bc furnirhcd wirh full ond holl nur lor SY-Conncction.

Wt, (Approx.) Lbs


LAI & LBI
I{ANGFP (I7F tA tB c
--u.i
F
rlvlCFlJl -9.i
Ll -Tt L
N TITI W Nei 5hpo.
5f, ','1 I l 5'r 650 680
37 - 6.
I
aAf. I a'/, 25'A l'/. !/" {',/. 7',/, .'a

t Mdr- diF...io lr grogt. di6'n'ic'r o' ccalication'


tTc6ct.r.d dimnri.6 do oor crpl, t6 unir. J!6or.d by (a) ir si.G s.l.dion cho'r F 819. l.stollihs 'Yoil'llG

ROD 5ELECTION CXINT ffi


ROD DIA. (R) lth rr5 lt/t 2 '2Y.

LOAD. 8.000 r.630 rs700 I 20.700 I 27.200


lnclude addltlonal l5t for Possible field load adjustmnt
Rod Selection-the total load should an
ino irti-reieht of the unit for typerA.f onlyr(All
-- {? fit).
i'ii"io-niiui"enents-tz; R-H- tnriia lensth thrrads national coarse

Dimensions Provided For


User APPlication OntY

FOR ORDERING INSTRUCTIONS


SEESHEETSs&9
PART 4IOO
BERGEN+ATERSON PIPE SUPPORT CORP.
DATE 6'l'r g-g3
LOAD CAPACITY DATA SHEET
for
NUCTEAR POWER PLANT COMPONENT STANDARD SUPPOTTS

CONSTANT SUPPOI?T HANGES.


{1 16'l

4100-LAl 4100-LBl
4100-rBIa
DIRECTION
OF
LOADING
LOAD RATING (lbs-.)
DESTGNED By: i:::-ear i.nal'zs i s cl. l, 2. 3, & MC TEMPERATURE ]-? O
"-OT
OPERATING CONDITIONS
OESIGN Le,rel A,1., B Le,rel C Leve I D

coNotiloN NORMAL & UPSET EftTERGENCY FAULTED


.l 1
-l 22325 22325
{8 24290 24290 z,
2520A )G)nn
-J4gV
--
5C zELL5 28lL5
30590
33065
53 35900 35900 '-
i-
4L{cc 41400
t .. I An
-{.lrUU 44100
>t 4.7 L3 0
i 58 50253 30250
jj700 3700
60 54 C00 54000
lailuflte<i lcacis siown are maxinum rated values at m:-ni::rl5o total travei
offer:i fc= each uni-. size- F.efer to size Sel ect:cn Table on Sheets
6 3,9 icr :oad-T:al'e1 combinations -

Loads siloH:r per:3d r-- :-ielC load ad justnen;- of up tc + i51 '"/ithou*- exceei-
irg alictrable st:ess ',-alues.
rload rai:::g for all com-Ecnents exceP+- ior '.emperature eiiect on sprinE
coiL. Stnr caiculctionr or t.d doto for thir prcdu<f
wccr por{orrnrd in cccordomr with:
1-5:9 3r i018 C't** A.Slr.E SECnON m. SUE36CnON Nf
) f**
:{r COlllPOt{€llT SUPPOT$ (dcrr ot ixtuo 7.1- li)
cnd orooa lilo cr:
i l.- 1CE r:r i n1 Q*:f,

3 , SA-133 Cr" 87
(scrino coil bear':ngs, Iers.i EEEGEN-PATERSON
cnr\ 1.'as ,t?csazFottawtntnod
U:I i rina r )lF. 2\21 i &lcor
I
t4 ttcr,la(ttutac.0traa.4 s
^
rn **Cooe Case I tlf'-6 Consrol - 4000
li at PATI HO.
BERGEN.PATERSON PIPESUPPORT CORP. 4100
gHCfT
IOAO CAPACITI DAIA
Sle'.{F i
ri
rls rJFF ,lr
.5\r
.?Y1
B
Lo

rffi
iL * -a

TAx€ -OrJT
/ sil
rll
I
Eo
llxe{r?
rAxE-qrr
,,'fioA ; I --6-
I

;o---r-

ffi '*" I
"-, l.
Eb
lt

5 Y - CONN ECTI ON

* Same as LB1 except toP 1ug rotated 90 degrees.


Product of l^Ielded Construction. Produst of weHed
Comtntcdott
LAI & LB
22',/,122 l'22 l2l:, 21 l2l .|20",120.,\ 20 il9'."119 llSi;
I I '/,'129 |.29 128 27 126"\ 26 126 125';125 124"\121

od tokc-oul is lor down rrovel (cold to hot); lot up ?rovcl, dimenrionr sho*n rhosld bc increosed by ocruol irovel dttn.naroo.
'Turnbucklc ond bolt nor furnirhcd with thcsc unilr: connccting rod to bc futnished with full ond holl nur for SY-Conncction.

LAI & LBI

ll&:_- dimcnrion lor group.

ROD SELECTION cH A R_l 17 to 6A )

RoD DtA. (R) ztt Loads exceeoing nn'ax


I tlr lY. 2 2V

ls700 I I specifj-ed require


LOAD- I 11.630 zo.zoo zz,zoo :t3 d00
non-standard rod
Rod Selection-the total load should lnclude an additional 15t for possible field load adjustment
conlrections.
and the reight of the unit for typeul only.
Thread Requirennnts-le' R.H. rhread length (All threads national coarse l2 fit).
Dimensions hovided For
User Application OntY

FOR ORDER I I.IG I I'ISTRUCTI ON

SEESHEETSB&9
PART 4ICO
BERGEN.PATERSON PIPE SUPPORT CORP.
DATE 8-i 8-83
F!{n 6t.xFa

LOAD CAPACITY DATA SHEST


for
NUCLEAR POWER PTANT COMPONENT STANDARD SUPPOffiS

CONSTANT SUPPORT S I ZE SELECT I ON TABLE


IT-i" .t.r-r - rtlXll Utr RATE
{Tho aiaiova tooo rr rh. lood lor tt'. ol!!!4i!!-!.!s-3.4
4r', I-- | 5ti
FOR SIZES I THRU 7 SEE PAGE I'.
605 | 505 13sl 38ol J35 los-l- ,rs t 2is i 23s | 2t5 I :05 | leo
773 I 505 s20 I {55 I .r05 3651 r30l 30sl 2801 2601 2151 230

I-oso-T srot 540 l_fgoI {65 I 135 I {

1605 I 1335 I ll4


r- ees I eoo I al5l 500 r 560
1655 I l4l5
I t230 | lll0 I :010
18 -T I 2.t.t5 I 20{5 r36s I t22S il 15 I 1020
-1060 272OT- 7255 i- ledo I 1670 I lslg I I
1070 I 99J I

t650 I I 1175t i2701 ll80l 1100


I 3600 I 1000 I 2575 I i385 r 1285 I r2C0 I ll
1525 i 1.
:4001 {320r 3 t60l le65l I 1665 r 15,15 I l{40
se{o-T- 17s5T 3960 t rrgs | 2e70J }!le l60r 19801 ls30l 1700
I 5l85 I r I 2160 | 1995 i 1855 I 1730 I 16

:sosI 3{:sl:ttoi 2a5s | ?435 I ?1r5 I :235 l2lr0


75 I 3190 I

7215 | 6l raro r 1330 I 3e35 i j!q0l--:-l-l-q-L--j!.!gl


?t
11 d5l 5260t !7aO
J. I i il7oorl 9640 I 8265 I
trs3t 11301 iaast !610

i : r ll760rt 10060 7EI'6-T- zoSS r aars i s8so | )430 | 5040 t :600 i r{10
n -i i :l3055rlll80l 9790 s70ot 783ti-71201 65301 60301 jllsl 51701 .t8e5

o-ZE-T--T3E5-T--d725 I 7ee5 I 737st 6ry91-__9

{t I ' tlgll0^ll
l3390lt2l70tlll60
mi5-T-mEs fll825 I 10910 I l0l3s I e{50 I EE6o

i 2r700^l icosoel 16925 r l5


70rl 18100 6295 I 14815 I
-i
ffi r 3 zro ! _]_2_Dl_i_11!t9_illl
I
19.25 i I d9a5 13870 I t2960 |
llgto I 13100
r:gt ts i '.14990I 2

: i I 17 195 I ?rir75 i i7{t0 : i6320 | I


st---l---- lJo i
:8910 I 176.O
t9l 15 |
i la,l.o r llo3o I 2al9o I

iExo-T-:rooo i :edoo I 2?r!5 I zs2oo I 2

I t2710 I :05

Conrtont SuPPocrr
NOT E:
J5,{50 I r1550 I

:hogid bc rciccted wirh :uifi'


cicnt ovcr.trovci lo ingulr on
ao€ouote trovci rctcrvs thul 7ro0 I 53300 I re800 I {6t50
;roviding for ony porribla
oircrcooncy bctwccn thco'
rcrrcoi onri octuol piping

I i':n:::l L]3 rt'r: :vorrtora'" I rc 'lo,


lor c3/ onq ii3 s..t ;ubta€r to ,crlcllon rlaf, tttr?3.
t i.cqrroat

Oraering Inst:uctions :
Specriy- Par+- Nc - , TYPe, Loai ,:apaci:: Data Sheec
?.ev. No. , S j-ze Desig:racion, )la.r:< )lo. Cperatiagr
Load., Tctal Travel, thermal i'!vt . , anc Direct i.cn
C to ,': , Dia. ano Material of S uppor=ing Rocr
(C.S. or li.S.) -
IxannnLe: .i10C-LBl-R/1 -9, l1k- PJIS-7, O'L' 5201r,
T.T. 3-L/2", l'Ivt .2-L/2" ii?, P.od Dia.
5/8" C.S-

BERGEN-PATERSON PI PESUPPORT CORP.


i srssr I ^::' PARTHO.

SEAI q /t/tt SIGI{ED LOAO CAPACTTY OATA SI{TCI i * o, 9 ! 'oj d100


tlrn C?.IFI

LOAD CAPACITY DATA SHEET


for
NUCLEAR POWER PTANT COMPONENT STANDARD SUPPOffiS

CONSTANT SUPPOP.T SIZE SELECTION TABLE


li ron EAcl{ 5lz€
i*.--.---,." r.., - gr, ftt. t"t! f"oa to"q. t"t.,..
f' lo I I

lsot rTol 160l !

NOTE: Conrtonl SuPporrr


rhould be rcicctcd with luifi'
cient over.trovcl to in:urc on
odrquota trovcl relcrve t{rul
i-3EFi lso i 330,1---flu9l provrriing [or cny Porriblr
di:crcocnqT bct*ccn rheo'
!36-T--i6-l-Toi | 3eo :75 rcricol onci octuoi Piping
l5Er {3oi rlo movGmca?-

720 t 6t5 I

IOSO | 1035 i ?e0 I

:{30 I ;j65 I r5 I il90 I

lll0l I 1040
1200t llr0 10401 970
I ld90 I lt r3'i0!!??0 lll40 ll
I t9t0 I i8
I l{15 | l

2020! 13751 1750

,i
' "r ---lt-. 'l
I

I
:l.i.l :seot:ltol 12551 301

cua> : 45!5 I .

I r.55 I .t I 35. | 3a6o

irc65 I I
i ao65 , ;.ras I a99o I 6550 I !!
1870 r u2r
rrrio i r36Jo | 12935 Ll in"66o t tot9s t 9620 1 3710 l 3160 r 7

12525 1 l?C20 11525 | l! t0185 | ?{


tolrr970lll050r!
16160|15500Il{790|l{ ffiiLotu_l__:l!9_l5l
ffifor ltgtoI t5o!5rltr25 lr
iiii tsgrot 180051 l7lr0l I tJsr0 t t3t8o I 12580 I llTr
I 17900 r 16520 ; i5310 ri:roir3.r3ot tq
iTlB.rol-2oteo I lee?t I ieo6o I l7

20650 | 54
i- rrooTl?{co I 37300 l 3:600

61a001583001553t0

Oree::-:lg Inst,=uctj-cns :
Spec \:l Par-- )Io - , T!'Pe , Load Capacat:'Dat,a Sheet
Re-r. )lo.r Size Desigracj-on, Mark -\..o. Ogeracing
Loai, 'Total T=a';el, lhennal M'/t. , and, Direction
I C to J, Dia. aio Material of Supgortlag F.cC
*rlr> !
I
1==- / ls. lr
(C.S. or I{.S.) -

SxampIe: ,1100-LBI-R'i 1-9, :'Ik. R-HH-?, O.L ' 520i '


- T.T. 3-L/2",Ilvt.2-L/2" UP, Rod Dj-a.
5/8" C.S

SHEET PATT ilO.


BERG EN.P AT.ERS.OTTI PI P€5 RT CO RP. !
;! I i1,n
a /.t/-- YTSO 9 --3
CERTIFIED DESIGN REPORT SUMMARY

H
rH;
Hd
MACHINE THREAD ROD
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS

DIRECTION
OF
LOADING

Temperature:ff
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100 f.
For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-5000 R0


v 7
q, DESIGN REPORT NO.: DR-5000 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size (see Note)
Condition Level A Level B Level C Level D
3/8 610 610 810 915 1 140 810
1t2 1130 1130 1500 1695 2120 1500
5t8 1810 1810 24/J,O 2715 3400 2400
314 2710 2710 3500 4065 s090 3600
1 4960 4960 6600 744o 9320 5600
1-1t4 8000 8000 10600 12000 15040 10600
1-1t2 1 1630 1 1630 15500 17445 21860 15500
1-3t4 15700 15700 20900 23550 29510 20900
2 20700 20700 27600 31050 38910 27600
2-1t4 27200 27200 36200 40800 51130 36200
2-1t2 33500 33500 44600 50250 62980 44600

NOTE:
SA- 307 Gr. B hex nuts may be used as a part of this component standard support at the above
load ratings.

lc"^"Yry
equirements of the applicable Code. I
Materials; The Design Report & Design Specification
t-
o Rod: 54-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at:
o)
ul
:)
o Bergen Power Pipe Supports, lnc.
a
J
Product Englneering Deparlment
z
(,
ro ]ONTROL REF NO. 5OOO
PART NO,
BERcEN-powER ptpE s.tppo?rs, rNc.I i:Tl I K 5000
REV Certitication
MACHINE THREAD ROD

STD.
ROD SIZE THREAD LENGTH
THREAD
A
T{ T2

3t8 3/8 16 UNC -2A 6 6

1t2 1t2 13 UNC -2Al 6 6

5/8 5/8 11 UNC - 2A 6 6

314 3t4 - 10 UNC -2Al 6 6

s \sf { 1 1 8 UNC.2A 6 6
REV

1-114 1-114 - 7 UNC -2A 6 6

1-1t2 1-1t2 - 6 UNC -2A 6 6

1-314 1-314 -s UNC -2A_ 12 12

2 2- 4-112 UNC - 2A 12 12

2-114 2-1t4 - 4-112 UNC - 2A 12 12

2-112 2-1t2 -4 UNC -2A 12 12

NOTES:
1. All dimensions are in inches.
2. Dimensions are provided for user application only.
o 3. Part No. 5000 as shown. (right hand threads, both ends)
o
o, 4. Part No. 5001 with special thread. (right and/or left hand threads)
l! 5. Quantity of hex nuts must be specified if required.
f
a
U)
J
z Orderinq lnstructions:
o Specify part No., CDRS revision No., and size designation.
e
o
<" G Example: Part 5000 - FU0.1" x 3' ' 8" Lg.
IEV

nns BERGEN-POWER PIPE SUPPORTS PART 5OOO


Hd
H CDRS CATALOG INFORMATION SHEET DATE 91112007
Effi CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
EONTINUOUS THREAD ROD

DIRECTION
OF
LOADING

Temperature: @iE
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-5000 R0


7 7
(',
{ (a) DESIGN REPORT NO.: DR-5000 R0
REV cl
Rated Loads (lbs) lor Classes ,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size Level D (see Note)
Condition Level A Level B Level C
3/8 610 610 810 915 1 140 810
1t2 1130 1130 1500 1695 2120 1500
5/8 1810 1810 24AO 2715 3400 2400
314 2710 2710 3600 4065 5090 3600
1 4960 4960 6600 744fJ/ 9320 6600
1-1t4 8000 8000 10600 12000 15040 10600
1-112 11630 11630 15500 17445 21860 15500
1-3t4 15700 15700 20900 23550 29510 20900
2 20700 20700 27600 31050 38910 27600
2-1t4 27200 27200 36200 40800 51130 36200
2-1t2 33500 33500 44600 50250 62980 44600

NOTE:
sA- 307 Gr. B hex nuts may be used as a part of this component standard support at the above
load ratings.

I Cenrry Inrs uuFtD


"ornp@
'equirements of the applicable Code. I

Materials: The Design Report & Design Specilication


r\
o Rod: 5A-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at:
o,
uJ
f
a Bergen Power Pipe Supports,lnc.
a
J Producl Englneering DePartment

o
=
E
o 3ONTROLREFNO. 5006
Sheet REV. PAtt I NU.
BERGEN-POWER PIPE SUPPONTS, INC. lof 1 5006
REV Certification

^\
CONTINUOUS THREAD ROD

A
l-_
r ROD SIZE
L rI/4"
L
THREAD
A
MIN. MAX.

3/8 3/8 16 UNC -2A_ 6 6'-0"

112 112 13 UNC -2A- 6 6'-0"

5/8 5/8 11 UNC - 2A 6 6"0"

3t4 3t4 - 10 UNC -2A- 6 6'-0"

{t sl 1 1 8 UNC -2A 6 6',-0"


REV
1-114 1-1t4 - 7 UNC -2A- 6 6',-0"

1-112 1-112 - 6 UNC -2A- 6 6'-0"

1-314 1-314 - 5 UNC -24 12 6"0"

2 2- 4-112 UNC -2A 12 6'-01'

2-114 2-1t4 - 4-112 UNC - 2A 12 6'-0"

2-112 2-112 - 4 UNC -2A. 12 6''0"

NOTES:
1. All dimensions are in inches.
F-
2. Dimensions are provided for user application only.
o 3. Longer lengths availablre, if required , on special order.
o
o,
lrJ
f
U)
9,
J
Orderinq lnstructions :
z Specify part No., CDRS revision No., and size designation.
o
e.
o
G G Example: Part 5006 - R/0-1" x 3' ' 8" Lg.
REV
PART
ffi
H
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET DATE
5006
91112007
tit J. ri
E
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

FORGED SIEET TURNBUCKLE. PART NUMBER 51OO

DIRECNON
OF
LOADING

t Temperature: 3500F

Nott'
For, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-5100
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-5100
shown for $e Operating Condition.

OperatinE Conditions Test Condition


Size Design Condition
Level A Level B Level C Level D lsee Note)
3'8 730 730 971 1,095 1,460 971
112 1,350 1,350 1,796 2,Azs 2,700 1,796
5'8 2,130 2,130 2.833 3,195 4,260 2,833
3t4 3,230 3,230 4.296 4,845 6,460 4,296
1 5,900 5,900 7,847 8,850 11,800 7,947
1114 9,500 9,500 12,635 14,250 19,000 12,635
11t2 13,800 13,800 18,354 20,700 27,600 18,354
13//4 18,600 18,600 24,738 27,900 37,200 24,738
2 24,600 24,600 32,718 36,900 49,200 32,718
21t4 32,300 32,300 42,959 48,450 64,600 42,959
21t2 39,800 39,800 52,934 59,700 79,600 52,934
Rated loads (lbs) for C/asses 1,2,3 &MC
I cerlify this CDRS complies with fie CONTROLREFNO. 51()()
requirements ol the applicatk code MATERIALS
The Design Report & Design Specification are in
Forqino: ASTM 4-668 CI-ASS C/D (CC N-249)
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Bergen Power Pipe Supports,lnc.
Studs: N/A
Product Engineering Department
Exempt N/A
REVISIONS
/i Oriqinal lssue 1 0/27109 /t
/t\
sEpJ- Va/zzhf lslGNED /z\ /i
BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REv.
a PARTNO. 51(l(}
litJ, al
CDRS CATALOG INFORMATION SHEET

-
FORGED STEET TURNBUCKLE. PART NUMBER'I0,O

ROD
S T
DIAMTER
3t8 71t8 9t16
1t2 7 1t2 3t4
5/8 7 7t8 15/16
3t4 81t4 11t8
1 I 1112
1 1t4 I 1/8 1 9t16
1 112 I3t4 17 t8
1314 10112 21t4
2 111t2 23t4
21t4 12314 3 3/8
21t2 131t2 33t4

1.)Alldimensions are in inches.


. 2.) Dimensions are provided for user application only.
3.) One end is right hand tap, one end is left hand tap'

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Rod Size.

DGMPLE: 5100-R/0-3/4"

REVISIONS
/0\ Oriqinal lssue 10/27109 /3'
'l
/A
/2\ /s'

BERGEN POWER PIPE SUPPARTS, NC. SHEET 1 OF 1 REV.


A PART NO. 51OO
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

FORGED SIEET CTEYIS . PART NUMBER 5110

DIRECTION
OF
LOADII{G

i Temperature: 3500F

Note:
For the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D95110
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. pR-lfllll
shown for the Operating Condition.

Rated Loads 1,2,3 &MC


I certify this CDRS complies with $e
requirements of the applicable code
The Design Report & Design Specification are in
ASTM A-668 CLASS C/D (CC
accordance with ASME BPVC Section lll, Subsection
NF 2007 Edition and are on file at:

Bergen Power Pipe Supports, lnc.


Product Engineering Department
Retainers NF-2121

lssue 10/27109

BERGEV POWERPIPE SUPPORTS, INC, PART NO. 5110


lir ft
:J
I
CDRS CATALOG INFORMATION SHEET

FORGED STEET CLEY'S . PART NUMBER 5110

raoFt-t.)
1 I

Grip Equals
Thickness of
Plate Plus/t"
,-- Grip
TAP BLANK
A c D E F PIN GRIP
stzE slzE
318 3112 1 7t16 1 5/8 1 5/16 1t2 2 1t2
1t2 3112 1 7116 1 5/8 1 5t16 5/8 2 5/8

5/8 31t2 1 7t16 I 5/8 1 5t16 3t4 2 5/8

3t4 4 21t2 1 114 11t8 1 5/16 7t8 21t2 3t4


1 5 3 1112 1 5/16 1t2 11t8 3 7t8
111/4 5 3 1 1t2 1 5t16 1t2 1 3/8 3 1

1112 6 31t2 1314 1518 1t2 1 5/8 31t2 11t4


13//4 6 4 2 13t4 1t2 17t8 4 11t4
2 7 5 2112 21t4 5i8 21t4 5 11t2
21t4 I 6
e
rJ 2314 3t4 21t2 6 11t2
2112 I 6 3 23t4 3t4 23t4 6 1314

NOTES:
' 1.)Alldimensions are in inches.
. 2.) Dimensions are provided for user application only.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Tap Size'

DGMPLE: 5110-R/0-3/4'

Part Number 5111is for Left Hand Threads.

REVISIONS
/3\
/o\ Oriqinal lssue
A /4\
/s\
./ z\

BERGEN POWER PIPE SUPPORIS, INC, SHEET 1 OF I REV.


A PART NO. 5110
tit f' d
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

FORGED STEET WELDLESS EYE VUT RIGHT HAND . PART NUMBER 5130

---r--
I

DIRECTION
I

OF
I
LOADING

i
Temperafure: 3500F

Nott'
Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D95130
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-5130
shown for the Operating Condition.

Operatinq Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
3'8 730 730 971 1,095 1,460 971
1t2 1,350 1,350 1,796 2,025 2,700 1,796
5'8 2,160 2,160 2,873 3,240 4,320 2,873
3t4 3,230 3,230 4,296 4,845 6,460 4,296
1 5,900 5,900 7,847 8,850 11,800 7,847
11Il4 9,500 9,500 12,635 14,250 19,000 12,635
11t2 13,800 13,800 18,354 20,700 27,600 18,354
13t4 18,600 18,600 24,738 27,900 37,200 24,738
2 24,600 24,600 32,718 36,900 49,200 32,718
2114 32,300 32,300 42,959 48,450 64,600 42,959
2112 39,800 39.800 52,934 59,700 79,600 52,934
Rafed Loads (lbs) for C/asses 1,2,3 & MC
lcertify this CDRS oomplies with he CONTROLREFNO. 5130
rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
'orqinq: ASTM A-668 CLASS C/D (CC N-249) accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Bergen Power Pipe Supports, lnc.
Studs: N/A
Product Engineering Department
Exempt N/A
REVISIONS
/o\ Orioinal lssue 10/27109 /)
ea-hK.C66 A /a,
*.Al Vo,/zz/a? ISIGNED /z\ /i
BERGEN POWER PIPE SUPPORTS, NC, SHEET 1 OF 1 REV.
A PARTNO. 5130
ti7 r, J
CDRS CATALOG INFORMATION SHEET
b

FORGED SIEET WELDLESS EYEA'UT RIGHT HAND. PART NUMBER il34

- --l- -
I

TAP SIZE
B c D E F G
A
3/8 11t2 1 3116 1t2 2 1 3/8 11t16
1t2 11t2 1 3/16 112 2 1 3/8 11116

5/8 11t2 1 3/16 112 2 1 3/8 11t16


3t4 11t2 1 3/16 1t2 2 1 3/8 11t16
1 2 111t16 3t4 25t8 115t16 1

11/i4 2112 1 13/16 1 3 3/8 2318 11t4


11//2 21t2 113116 1 3 3/8 23t8 11t4
13,4 4 4 1112 6114 4 21t4
2 4 4 11t2 61t4 4 21t4
21t4 4 4 11t2 61t4 4 2114
21t2 4 4 1112 61t4 4 21t4

1,) All dimensions are in inches.


2.) Dimensions are provided for user application only'

ORDERING INSTRUCTIONS :
Specify: Part Number, CDRS Revision Number, and Tap Size'

DGMPLE: 5130-Rl0-3/4'

REVISIONS
/il Oriqinal lssue 1 0/27109 /t\
/t /i\
/s\

BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV. A PART NO. 5130
tit ],
d
Y
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

FARGED SfEEt WELDLESS EyElrUT - PART NUMBER 5131 . Left Hand Tap

_f I
DIRECTION
OF
I
LOADING

Temperature: 3500F

*ott'
,0r' the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D95130
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-5130
shown for the Operating Condition.

Operating Gonditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
3'8 730 730 971 1,095 1,460 971
1t2 1,350 1,350 1,796 2,025 2,700 1,796
5'8 2,160 2,160 2,873 3,240 4,320 2,873
3t4 3,230 3,230 4,296 4,945 6,460 4,296
1 5,900 5,900 7,847 8,850 11,800 7,847
1114 9,500 9,500 12,635 14,250 19,000 12,635
11//2 13,800 13,800 18,354 20,700 27,600 19,354
13//4 18,600 18,600 24,738 27,900 37,200 24,738
2 24,600 24,600 32,718 36,900 49,200 32,718
2114 32,300 32,300 42,959 48,450 64,600 42,959
2112 39,800 39,800 52.934 59,700 79,600 52,934
Rated Loads {JbsJ for Classes t,2,3 & MC
I certify fris CDRS complies with lhe CONTROLREFNO. 5131
requirements of the applicabh code MATERIALS
The Design Report & Design Specification are in
Foiqins: ASTM A-668 CLASS C/D (CC N-249)
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Bergen Power Pipe $upports,lnc,
Studs: N/A
Product Engineering DePartment
Exempt N/A
REVISIONS
/N I Orioinal lssue 1 0/27109 /3\
At-*/,&.% /t /il
senl I lslcNED /i iJ

BERGETV POWER PIPE SUPPORTS, INC. SHEET 1 0F I REV. A PARTNO. 5131


CDRS CATALOG INFORMATION SHEET

FARGED SIEET WELDLESS EyE JUT ' PART NUMBER 5131 ' Left Hand Tap

_l_
I

TAP SIZE
B c D E F l.t
A
318 11t2 1 3t16 1t2 2 1 3/8 11t16
112 1 112 1 3/16 1t2 2 1 3/B 11t16
5/8 1112 1 3i16 1t2 2 1 3/8 11t16
314 11t2 1 3116 1t2 2 1 3/8 11t16
1 2 1 11116 314 25t8 1 15/16 1

1114 21t2 1 13/16 1 3 3i8 23t8 1 114

11t2 21t2 113116 1 3 3/8 23t8 1 1t4


13t4 4 4 1112 6114 4 21t4
2 4 4 11t2 6114 4 21t4
214 4 4 11t2 6114 4 21t4
2112 4 4 11t2 61t4 4 2114

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only'

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Tap Size'

DGMPLE: 5131-R/0-3/4"

REVISIONS
ioinallssue 10127109

PART NO. 5131


BERG EN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
FRICTION TYPE ANCHOR

DIRECTION
OF
LOADING

LOADIN€ DIA6RAA,I Temperature:650 " F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6015 R0


7
K { DESIGN REPORT NO.: DR-6015 R0
REV
FA (LBS) / MA (|N-LBS)
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
3t8 120/1000 120/1000 160/1333 180/1500 240t2000 160/1333

1t2 200/1600 200/1600 266t2133 300t2400 400t3200 266t2133

3t4 200/1600 200/1 600 266t2333 300t2400 400t3200 266t2333

1 400t3200 400t3200 533/4266 600/4800 800/6400 533t4266

11t4 600/4500 600/4500 800/6000 900/6750 1200/9000 800/6000

11t2 800/5500 800/5500 1066t7333 1200t8250 1600/1 1000 1066fl333

2 1000/7800 1000t7800 1330/10400 1500/11700 2000t15600 1330/10400

lcertify this CDRS complies with the


requirements of the applicable Code.

Materials: The Design Report & Design Specification


t\
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
a
o) Bar: 5A-36 Subsection NF, 2007 Edition and are on file at
UJ
f Studs: SA-193 GR 87
a
a Nuts: SA-194 GR 2H Bergen Power Pipe Supports,lnc.
J
Washers: SA-325 Ty 1 Product Engineering Department
z
Itr
o CONTROL REF NO. 601 5
PAHI N(,.

REV
BERGEN.POWEN PIPE SUPPORTS, INC.
Sheet
lof 3 AREV.
6015
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
FRICTION TYPE ANCHOR

DIRECTION
OF
LOADING

LOADINo DIAERA'I,I Temperature: 650 'F


NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6015 R0


rp DESIGN REPORT NO.: DR-6015 R0
REV
FB (LBS) / MA (|N-LBS)
Rated Load ls (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Gondition Level A Level B Level C Level D (see Note)
3t8 120/1000 120/1000 160/1333 180/1500 240t2000 160/1333

1t2 200/1600 200/1600 266t2133 300/2400 400t3200 266t2133

3t4 200/1600 200/1600 266t2333 300/2400 400/3200 266t2333

1 400/3200 400/3200 533/4266 600/4800 800/6400 533t4266

11t4 600/4800 600/4800 800/6400 900/6750 1200/9600 800/6400

11t2 800/6000 800/6000 1066/8000 1200/9000 1 600/1 1000 1066/8000

2 1000/8000 1000/8000 1330/10666 1500/11700 2000t16000 1330/10666

I certify this CDRS complies with the


requirements ol the applicable Code.

Materials: The Design Report & Design Specification


i-
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
o, Bar: 5A-36 Subsection NF, 2007 Edition and are on file at
Lu
f Studs: SA-193 GR 87
a
a Nuts: SA-194 GR 2H Bergen Power Pipe SupPorts,lnc.
J
Washers: SA-325 Ty 1 Product Englneerlng DePartment
z
g
tr CONTROLREFNO. 6015
o
PART NO.
Sheet
BEBGEN.POWER PIPE SUPPORTS, INC. /ot 3 /N 6015
REV Certification
CERTIFIED DESIGN REPORT SUMMARY
TFA
Nd
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
H FRICTION TYPE ANCHOR

DIRECTION
OF
LOADING

Lq4AtM E49B4r Temperature:ff


NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6015 R0


tp DESIGN REPORT NO.: DR-6015 R0
REV
FC (LBS) / MA (|N-LBS)
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
3t8 120/1000 120/1000 160/1333 180/1500 240t2000 160/1333

1t2 200/1600 200/1600 266t2133 300/2400 400/3200 266t2133

3t4 200/1600 200/1600 266t2333 300t2400 400/3200 266t2333

1 400/3200 400t3200 533t4266 600/4800 800/6400 533/4266

11t4 600/4800 600/4800 800/6400 900/6750 1200/9600 800/6400

11t2 800/6000 800/6000 1066/8000 1200/9000 1600/1 1000 1066/8000

2 1000/8000 1000/8000 1330/10666 1500/1 1700 2000t16000 1330/10666

rcenrryInrs uuHD
"o.o@ Code. I
equirements of the applicable

Materials: The Design Report & Design Specification


t\
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at
o) Bar: 5A-36
TU
fa Studs: SA-193 GR 87
a Nuts: SA-194 GR 2H Bergen Power Pipe Supports, lnc.
J
Washers: SA-325 Tv 1 Product Engineerlng Department
z
g
tr CONTROLREFNO. 6015
o
PART NO.

EV Certification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet
lof 3 A 6015
FRICTION TYPE ANCHOR

STUD DIA.

I [, -f
6 6 REO'0.
TORQUE
REV
PIPE STUD PER BOLT
A B c D E F G H
SIZE DIA. IN-LBS.

3/8 5 41t4 315/16 3ffi 23t4 3 3t4 1 3/16 5/8 170

1t2 5 41t4 4 3ffi 23t4 3 3t4 1 1t4 5/8 290

3t4 5 4114 458 3112 23t4 3 3t4 1 1t4 5/8 140

1 5 43t4 4 7t8 3112 31t4 3 3t4 1 5/8 5/8 260

11t4 5 5114 5 1/8 31n 3314 3 314 2 5/8 300

1ffi 5 5112 5 1/8 3112 4 3 3t4 2 1n6 5/8 290

2 5 6114 5 3/8 3ffi 43t4 3 314 2ffi 5/8 330

NOTE
1. All dimensions are in inches and are provided for user application only.

r-
ORDERING INSTRUCTIONS:
o Specify Part Number, CDRS Rev. No. and Pipe Size
o
o)
UJ
:f E)GMPLE: 6015-R0-2"
a
ct>

J
z
0
tr
o
<" - G
REV

ffi
H
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART 6015
DATE 911 t2007
CERTIFIED DESIGN REPORT SUMMARY
rH;
Hd
fl 2-BOLT PIPE CLAMP
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

DIRECTION
OF
LOADING

Temperature:ff
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown lor the Operating Condition.

DESIGN SPEC NO.: DS-6100 R0


K ft DESIGN REPORT NO.: DR-6100 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size
Gondition Level A Level B Level C Level D (see Note)
4 1000 1000 1330 1500 2000 1330
5 1000 1000 1330 1500 2000 1330
6 1600 1600 2128 2400 3200 2128
I 1600 1600 2128 2400 3200 2128
10 2400 2400 3192 3600 4800 3192
12 2400 240/0 3192 3600 4800 3192
14 2400 2400 3192 3600 4800 3192
16 2400 24AO 3192 3600 4800 3192
18 3000 3000 3990 4500 6000 3990
20 3000 3000 3990 4500 6000 3990
24 3000 3000 3990 4500 6000 3990
30 3500 3500 11655 5250 7000 4555

'*""ttW
equirements of the applicable Code. I

Materials: The Design Report & Design Specification


tr
o Plate:5A-36 are in accordance with ASME BPVC Section lll,

o) Studs:5A-36 Subsection NF, 2007 Edition and are on file at:

ffi
L.IJ
Nuts: 5A-563 Gr. A
cn
a CLOUTIER Bolts: SA-307 Gr. B Bergen Power Pipe Supports, Inc.
-.'] Product Engineering Department
1
Cotter pins, Washers, Retainers Exempt (NF-l1 10)
tr SONTROL REF NO. 175
PART NO.
SE BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

REV Certilication l-or ! /N 6100


2-BOLT PIPE CLAMP

UP5ET THREAD5 AFTER


TNSTALLATTON (NF-4725)

Pipe Size A c D E F Stock Size

4 4-318 314 4.a,B 3-5/8 5t8 1l4x 1-112

5 4-15116 314 4-15t16 4-3tI6 5/8 114x 1-112

6i 6i 6 5-718 7//8 5-718 5 314 318x1-112


IEV
I 7 1 7 6-1/8 314 318x1-112

10 8-9/16 1 8-9/16 7-7116 7t8 112x2

12 9-9/16 1 9-9/16 8-7116 718 1li2x2

14 10-s/8 1-1//8 10-5/8 9-1t4 7t8 112x2-112

16 11-518 1-1t8 11-5/8 10-1t4 7t8 112x2-112

18 13 1-114 13 11-518 1 518x2-112

20 14-118 1-3/8 14-118 12-3t4 1 518x2-112

24 16-718 1-5/8 16-7t8 15-1t4 1-1t4 5/8x3

30 20-314 2 20-3t4 18-1t2 1-112 314x4

F-
o NOTES:
o 1. Clamp shown with bolts. Studs may be used at manufacture's option. ln
CD
LrJ
f that case, upset threads at ends after installation.
a
U) 2. Dimensions provided for user information only.
J
z Orderinq lnstructions :
o Specify part No., CDRS revision No., and size designation.
&
o
G G Example: Part 6100 - R/0 - I
REV

r77f, BERGEN-POWER PIPE SUPPORTS PART 61 OO


Hfl
U CDRS CATALOG INFORMATION SHEET DATE 91112007
CERTIFIED DESIGN REPORT SUMMARY
rf,n
fr
Hd
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
HEAVY 2-BOLT PIPE CLAMP

DIRECTION
OF
LOADING

Temperature:650 f
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6100 R0


DESIGN REPORT NO.: DR-6100 R0
F tEV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size
Condition Level A Level B Level C Level D (see Note)
3 3400 3400 4522 51 00 6800 4522
3-112 3400 3400 4522 51 00 6800 4522
4 3550 3550 4722 5325 71 00 4722
5 3550 3550 4722 5325 7100 4722
6 4900 4900 651 7 7350 9800 651 7
8 4900 4900 651 7 7350 9800 651 7
10 6000 6000 7980 9000 1 2000 7980
12 8700 8700 11571 1 3050 17400 11571
14 91 50 91 50 12170 13725 18300 12170
16 91 50 91 50 12170 13725 18300 12170
18 91 50 91 50 12170 13725 18300 12170
20 91 50 91 50 12170 13725 18300 12170

-"ry
'equiremenls of the applicable Code. I

Materials: The Design Report & Design Specification


Plate:5A-36 are in accordance with ASME BPVC Section lll,
Studs: 54-36 Subsection NF, 2007 Edition and are on file at:
Nuts: SA-307 Gr. B
Bolts: SA-307 Gr. B Bergen Power Pipe Supports, lnc.
Product Englneering Department
Cotter pins, Washers, Retainers Exempt (NF-11 10)
SONTROLREFNO. 298
Sheet REV. PART NO.
BERGEN.POWEN PIPE SUPPORTS, INC, lofl /a\ 6101
REV Certification
HEAVY 2.BOLT PIPE CLAMP

II c

UPSET THREADS AFTER


TNSTALLATTON (NF-4725)

Pipe Size A c D E F Stock Size

3 4 7t8 4 3-1/8 3t4 318x2

3-1t2 4-1t4 7t8 4-1t4 3-3/8 314 318x2

\lJ) 6 4 4-7tA 1 4-7t8 3-3t4 7t8 318x2


tEV 5 5-1t2 1 5-1t2 7t8 318x2

6 6-5/8 1-1t8 6-5/8 5-1t4 1 112 x 2-112

I 7-5t8 1-1t8 7-5t8 6-1t4 1 112 x 2-112

10 9-1/8 1-3/8 9-1/8 7-3t4 1-1t4 5/8 x 2-112

12 10-7t8 1-5/8 10-7t8 9-114 1-1t2 314x3

14 11-7t8 1-5l8 11-7t8 10 1-1t2 314 x 3-112

16 12-7t8 1-5t8 12-7 t8 11 1-1t2 314 x 3-112

18 13-7t8, 1-5/8 13-7t8 12 1-1t2 314 x 3-112

20 14-7t8 1-5/8 14-7t8 13 1-1t2 314 x 3-112

NOTES:
1. Clamp shown with bolts. Studs may be used at manufacture's option. ln
l-
o that case, upset threads at ends after installation.
o
F

2. Dimensions are provided for user application only.


o,
uJ
f
U)
a Orderino lnstructions:
z Specify part No., CDRS revision No., and size designation.
(,
[E
o Example:
G G Part 6101 - R/0 - 10
IEV

ffi
fl
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE
6101
9t1t2007
LOAD CAPACITY DATA SHEET
for
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS
PIPE SADDLE
I -\-
./l:r-

I
DIRECTION

rof,iruc
DESIGNED BY: LOAD RATING TEMPERATURE:650 T
LOAD RATTNG (LBS)
for Class 1,2,3 & MC
OPERATING CONDITIONS
DESIGN
SIZE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
{o {o \< NORMAL UPSET EMERGENCY FAULTED CONDITION
EUI> 4 1000 1 000 '1330 1500 1 880 1 330
5 1 000 1 000 1 330 1 500 1 880 1 330
6 1 000 1 000 1 330 1500 1880 1 330

8 1 000 1 000 1 330 1 500 1 880 1 330

i- 10 1 200 1 200 1 596 1 800 2256 1 596


oI

I
12 1 500 1 500 1 995 2250 2820 1 995
ct)
14 2000 2000 2660 3000 3760 2660
]u
d] 16 2500 2500 3325 3750 4700 3325
F 18 3500 3500 4655 5250 6580 4655
o zJ- 20 4000 4000 5320 6000 7520 5320
o
J f- 24 6000 6000 7980 9000 11280 7980
f-t
o
lu o 30 7500 7500 9975 1 1250 14100 9975
(9
U) 2 I
(\l 36 11000 11000 1 4630 1 6500 20680 14630
uJ
E o
o @I E(U
z C\l
I
o
E o
o
IU
o
L
o t
o)
UJ
o EE
o
() (6
ul IU
F-
o o 2 NOTE: I certify that this LCDS complies Materials:
gllEo9 gElq
(L rU tr
wql9ulqtlvll- 9l fg-f rga llll-
with the requirements of the applicable Prvs!

= o code. Plate: 54-36 performed in accordance wlth: ASME BPVC SECTION lll,
SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon
6 Bolts: and are on file at:
EIJJ> Pin:
\uts: BERGEN-POWEB PIPE SUPPORTS, INC.
IU Studs: Product Engineering Department
=
o A
o 3otter pins, Washers, Retainers Exempt (NF-1110) CONTROLREF. NO. 6140
g BERGEN-IowER ptpE suppo+rs, INc. ,ART N(
E
o
IFT]
?rI LoAD cAPActrY DATA SHEET
Sheet
_!of 1 A REV.
61 40
COVERING THfCKNESS = 4"

PIPE
c L oo T T,
Tr stzE
4 61t2 4 7t16 20" 3/16

5 7 413t16 20" 3/16

6 7 1t2 5 3/16 20" 3/16

8 8 3t4 6 20" 1t4

10 I3t4 611/16 20" 1t4

12 10 3t4 11 15/16 30" 3/16 3/16

14 11 1t4 12 9t16 30., 1t4 3/16

16 12 1t4 131t2 30" 1t4 1t4

18 131t4 14 5t8 30" 1t4 1t4

20 141t4 15 3t4 30" 1t4 1t4

24 161t2 18 30" 3/8 3/8

191t2 21 1t2
VIEW A-A 30 300 3/8 3/8

36 221t2 25 30" 3/8 3t8

NOTES: 1. All dimensions are in inches.


2. Dimensions are orovided for user application onlv.

ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 6140-R/3- 8"

r77; BERGEN.POWER PIPE SUPPORTS INC. PART 6140


HJ
H CATALOG INFORMATION SHEET DATE 9t112007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
3.BOLT PIPE CLAMP

DIRECTION
OF
LOADING

Temperature: 650 f
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100 F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6100 R0


DESIGN REPORT NO.: DR-6100 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size Level D (see Note)
Condition Level A Level B Level C
1-112 1 500 1 500 1 995 2250 3000 1995
2 1 500 1 500 1 995 2250 3000 1995
2-112 1 500 1 500 1995 2250 3000 1995
3 1 500 1 500 1 995 2250 3000 1995
3-112 1 500 1 500 1 995 2250 3000 1995
4 2500 2500 3325 3750 5000 3325
5 2500 2500 3325 3750 5000 3325
6 2800 2800 3724 4200 5600 3724
8 2800 2800 3724 4200 5600 3724
10 3200 3200 4256 4800 6400 4256
12 3200 3200 4256 4800 6400 4256
14 4300 4300 571 I 6450 8600 571 I
16 4300 4300 5719 6450 8600 571 I
18 4300 4300 5719 6450 8600 571 I
20 5500 5500 7315 8250 11000 7315
24 6000 6000 7980 9000 1 2000 7980
30 8000 8000 1 0640 1 2000 1 6000 1 0640
36 8000 8000 1 0640 1 2000 1 6000 1 0640

I certify this CDRS complies with the


equirements of the applicable Code.

Materials: The Design Report & Design Specilication


tr
o are in accordance with ASME BPVC Section lll,
Plate:5A-36
o Pin:54-36 Subsection NF, 2007 Edition and are on file at:
o)
uJ
f Studs: 5A-36
U)
9. Nuts: 5A-563 Gr. A Bergen Power Pipe Supports, lnc.
J
Bolts: SA-307 Gr. B Product Englneering Department
z
0 Cotter pins, Washers, Retainers Exempt (NF-1110)
tr
o loNlH9L HEF NO. 304
PATII N(,.
\\ R
BERGEN-POWER PIPE SUPPORTS, INC.
Sheet

REV Certification
lofl K 6150
3.BOLT PIPE CLAMP

-.l
F c PIPE
c D E
G
F S
F
LJI
I
srzE Stock

f
1-112 1-1/16 +7t8 +1t8 114x1-112 5/8 2.3t8

2 1.1n6 5-7t8 5-1/8 114x1-112 5/8 2.3t4

2.1t2 1.1/16 6-1/4 5-112 114r1-112 5/8 3-1/16

3 1.1/16 6-11/16 5-15/16 114x1-112 5/8 3-3/8

3-112 1.1/16 6-15/16 G3/16 114x1-112 5/8 3-5/8

6 4 1-1/16 7-5t8 6-112 318x2 3t4 4.112


STOCK
srze 5 1.1 /1 6 8-1/8 7 318x2 3t4 5

6 1-7t16 10 8-5/8 318x2-112 1 6.3/16

UP5ET THREAD5 AFTER


I 1.7t16 1&15/16 9-9/16 318x2-112 1 7-1t8

TNSTALLATTON (NF-4725)
10 1-7t16 12.1t8 10-5/8 112x2-112 1 8-3/4

6 6 11-7t8 112x2-112 9.1t2


lEV 12 1.7116 13-114 1

14 2 14.5/8 13 5/8x3 1-114 11

16 2 15-7/16 13.13/16 5/8x3 1,114 1 1.13/1 6

18 2 16-1t2 14-718 5/8x3 1-114 12.7t8

20 2 17.7t8 16-1/4 3/4x3 1-112 1e3/8

24 2 19.11/16 18.1/16 314x4 1-112 16-3/16

30 2 26-1t2 24 1x5 1-314 20

36 2 30 27.1t2 1x5 1-3t4 2X1t2

l-
o NOTE:
o
F

1. Sizes 30 & 36 usestuds instead of bolts.


o,
[! 2. Dimensions provided for user application only.
:)
U)
I
J
z Orderinq lnstructions:
(, Specily part No., CDRS revision No., and size designation.
(f
o Example:
s G Part 6150- R/0 - 4
lEV

E7; BERGEN-POWER PIPE SUPPORTS PART 6150


U
Hd
CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
ffi
E
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
HEAVY 3-BOLT PIPE CLAMP

DIRECTION
OF
LOADING

Temoerature: 650 f
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS.61OO RO


7
(') DESIGN REPORT NO.: DR.61OO RO
REV Rated Loads 0bs for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
Size Level D (see Note)
Condition Level A Level B Level C
314 1 500 1 500 1 995 2250 3000 1995
1 1 500 1 500 1 995 2250 3000 1995
1-114 1 500 1 500 1 995 2250 3000 1995
5 5000 5000 6650 7500 1 0000 6650
6 8000 8000 1 0640 1 2000 1 6000 1 0640

8000 8000 1 0640 1 2000 1 6000 1 0640


8
10 11000 1 1000 1 4630 16500 22000 1 4630

11000 11000 1 4630 1 6500 22000 1 4630


12
14 12700 12700 1 6891 1 9050 25400 1 6891
16 12700 12700 1 6891 1 9050 25400 1 6891
18 12700 12700 1 6891 1 9050 25400 1 6891

20 1 5000 1 5000 1 9950 22500 30000 1 9950


24 1 5000 1 5000 1 9950 22500 30000 19950
1 5000 1 5000 1 9950 22500 30000 1 9950
28
30 1 5000 1 5000 1 9950 22500 30000 1 9950

36 1 5000 1 5000 1 9950 22500 30000 1 9950

equirements of the applicable Code. I


Materials: The Design Report & Design Specification
t-.
o )late: 54-36 are in accordance with ASME BPVC Section lll,
o Pin:54-36 Subsection NF, 2007 Edition and are on file at:
o,
uJ
l Studs: 5A-36
U)
Bergen Power PiPe SuPPorts, lnc.
I Nuts: SA-307 Gr. B
J
Bolts: SA-307 Gr. B Product Englneerlng DePartment
z
q Cotter pins, Washers, Retainers Exempt (NF-1110)
E L;ON IHL)L HEF NU. 91
o
PART NO.
ffi R
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

REV Certification Lor ! /il. 6152


3-BOLT PIPE CLAMP

tJr F
- PIPE
stzE
c D E F s Stock Size

f 314 5/8 4.7t16 3-1ln6 5/8 1-15n6 114x1-112

1 5t8 4-5/8 3-7t8 5/8 2.1t8 114x1-112

1-1t4 5/8 4-3t4 4 5/8 2-1t4 114x1-112

G 5 1.1t2 9-3/4 7-3t4 1.114 6 112x3


sTOCK
STZ;E
6 1.3t4 11.1t4 I FN 7.3t4 112x4

UP5ET THREADS 8 1-3t4 12-1t4 10 fin 8-5/8 112x4


AFTER INSTALLATTON
(NF-4725)
10 2 14.3/8 12 1-3t4 10-3/4 314x4

12 2 15-3/8 13 1.3t4 11-5/8 314x4

14 2.1t4 16-7/8 14 2 12-1t2 7l8xh1l2


cl 6x
REV 16 2-114 17.7t8 15 2 13.1t2 718x4-112

18 2-1t4 18.7/8 16 2 fl.1n 718x4-112

20 2-1t4 21 18 2 16-1t4 1x5

24 2-114 23 20 2 ft-1n 1-1/8 x 6

2g 2-1t4 27.1n 24 2 20-1t2 1-1/8 x 6

30 2-1t4 28-1t2 25 2 21-112 1-1/4 x 6

36 2-1t4 31.1t2 28 2 24.1t2 1-1/4 x 6

r-
o NOTE:
o
d 1. Glamp shown with bolts. Studs may be used at manufacture's option.
uJ
:) 2. Dimensions provided for user application only.
a
a
J
Orderino lnstructions :
(t
= Specify part No., CDRS revision No., and size designation.
(r
o Example:
AKrc Part 6152- R/0 - 4
REV

ffi
Y
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE 9t1t2007
61 52
tit L d
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

YOKE CIAMP RESTM'NT . PART NUMBER 6T75..7K

af-- 10' af-- 10'

DIRECTION
OF
LOADING

I
I

Temperature: 6500F

*o"t
Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operating Conditions Test Gondition


Size Design Condition (see Notel
Level A Level B Level C Level D
3 700 700 931 1,050 1,106 931
4 700 700 931 1,050 1,106 931
5 700 700 931 1,050 1,106 931
6 700 700 931 1,050 1,106 931

I 700 700 931 1.050 1,106 931

10 700 700 931 1,050 ,106 931


12 700 700 931 1,050 1,106 931
Rated loads (lbs) for C/asses 1,2,3 &MC

I certfy 0ris CDRS complies wilh $e CONTROLREFNO. 6175


requircments of lhe applcable mde MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports,lnc.
Studs: N/A
Product Engineering DePartment
Exempt Cofters, Washers, Retainers, Shims (NF-2121)
REVISIONS
/il Orioinal lssue 10/27109 /J
*sL,(.4'e A /i
/i
$EAL l/a/tz/ag lslGNED /^
BERGEfV POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REv.
a PART N0. 6175..7
CDRS CATALOG INFORMATION SHEET

YOKE CAMP RESTRA'NT . PART NUMBER 6175.,7K

*Q
PIPE SIZE c D E t, P T
FT.LBS
3 51t2 3t4 6 1t2 3/8 7,5 1

4 6 3/8 3t4 61t2 112 3/8 7.5 1

5 7 518 3t4 7 1t16 112 3/8 7.5 1

6 I3t4 314 7 9116 1t2 3/8 7.5 1

8 10 314 3t4 I 9/16 1t2 3/B 7.5 1

10 12718 3t4 10 5/8 112 3/8 7.5 1

12 147t8 314 11 5/8 1t2 3/8 7.5 1

1.)Alldimensions are in inches.


2.) Dimensions are provided for user application only'
3.) Minimum spring rate by test = 500 kips / in'
4.)This Clamp is compatible with B-P Parts 2015,2250,2252,2420 and2440.
* 5.) Torque Q tolerance = +l'10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

EMMPLE: 6175-.7-R/0-8.

Oriqinal Issue 1 0/27109

SHEET 1 OF PART N0. 6175..7


BERG EN POWER PIPE SUPPORTS, 1

'NC.
titD, d
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUGLEAR POWER PLANT STANDARD SUPPORTS

YOKE CUMP RESIRA''VT. PART NUMBER6l75-1.5K

ar- 10" aF- 10"

DIRECTION
OF
LOADING

I
I

Temperature: 6sooF

No"'
Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Gondition (see Notel
Level A Level B Level G Level D

3 1,500 1,500 1,995 2,250 2,370 1,995


1 1,500 1,500 1,995 2,250 2,370 1,995
,l,500
5 1,500 1,995 2,250 2,370 1,995
6 1,500 1,500 1,995 2,250 2,370 1,995
8 1,500 1,500 1,995 2,250 2,370 1,995
10 1,500 1,500 1,995 2,250 2,370 1,995
12 1,500 1,500 1,995 2,250 2,370 1,995
Rated Loads (lbs) for C/asses 1,2,3 &MC

I certity this CDRS complies with he CONTROLREFNO. 6175


mquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bol[ SA-193 87
NF 2007 Edition and are on flle at:
Nuts: SA-194 2H
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports , lnc.
Studs: N/A
Product Engineering DePartment
xempt: Cotters, Washers, Retainers, Shims (NF-2121)
REVtSt0NS
/il Oriqinal lssue 10/27109 /t
Eeit,(.il,,e /^
SEAL l/a,hz/af ISIGNED /^ /J

BERGEfV POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REv. a PART N0. 6175.1.5
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESTRIIINT . PART NUMBER 6175.1.5K

*Q
PIPE SIZE c D E t, P T
FT.LBS
3 51t2 314 6 5/8 1t2 32 1

4 6 3/8 3t4 6112 5/8 1t2 32 1

5 7 518 3t4 7 1t16 5/8 1t2 32 1

6 8314 3t4 7 9t16 5/8 1t2 32 1

I 10 314 3t4 I 9/16 5/8 1t2 32 1

10 12718 3t4 10 5/8 5/8 1t2 32 1

12 147t8 3t4 11518 5/8 1t2 32 1

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only'
3.) Minimum spring rate by test = 600 kips / in'
4.) This Clamp is compatible with B-P Parts 2015,2250,2252,2420 and 2440'
* 5.) Torque Q tolerance = +l- 10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

DGMPLE: 6175-1,5-R/0-8"

REVISIONS
lssue 10/27109

PART NO. 6175.1.5


BERG EN POWER PIPE SUPPORTS, INC.
CERTIFIED DESIGN REPORT SUMMARY
I
i"l NJ, b
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CLAMP RESTRII'NT . PART NUMBER 6175.4K

-1f-- "iF_ 10"

i- DIRECTION
OF
LOADING

I
I

Temperature: 6500F

Nott'
For, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

OperatinE Gonditions Test Condition


Size Design Condition (see Notc)
Level A Level B Level G Level D
3 4,000 4,000 5.320 6,000 6,320 5,320
4 4,000 4,000 5,320 6,000 6,320 5,320
5 4,000 4,000 5,320 6,000 6,320 5,320
6 4,000 4,000 5,320 6,000 6,320 5,320
I 4,000 4,000 5,320 6,000 6,320 5,320
10 4,000 4,000 5,320 6,000 6,320 5,320
12 4,000 4,000 5,320 6,000 6,320 5,320
14 4,000 4,000 5,320 6,000 6,320 5,320
16 4,000 4,000 5,320 6,000 6,320 5,320
Rated Loads (lbs) for C/asses 1,2,3 &MC

I certify this CDRS mmdies wi$ he CONTROLREFNO. 6175


rcquirements of lhe applicable code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: SA-564 TYP 630
Bergen Power Pipe Supports, lnc.
Studs: N/A
Product Engineering Department
Exempt: Cotters, Washers, Retainers, Shims (NF-2121)
REVISIONS
/dr I Orioinal lssue 1 0/27109 /3\
t#hR.(4fr 1 /i
SEAL lza /zz,/af I SIGNED l/z\ /i
BERGEN POWER PIPE SUPPORTS, SHEETl OF 1 REV.
A PART N0. 6175-4

'NC.
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESIRA'AJT - PART NUMBER 6175.4K

*Q
PIPE SIZE c D E t P T
FT.LBS
3 51t2 3t4 6 5/8 1t2 32 11t4
4 6 3/B 3t4 6112 5/8 1t2 32 11t4
5 7 5t8 314 7 1t16 5/8 1t2 32 11t4
6 8 314 3t4 7 9/16 5/8 1t2 32 1 1t4
8 10 3t4 314 I 9/16 5/8 1t2 32 11t4
10 12718 314 10 5/8 5/8 1t2 32 11t4
12 147t8 3t4 115t8 5/8 1t2 32 11t4
14 16 1/8 3t4 12114 5/8 1t2 32 1 1t4
16 18 1/8 3t4 131t4 5/8 1t2 32 1 1t4

1.) All dimensions are in inches'


2.) Dimensions are provided for user application only'
3,) Minimum spring rate by test = 1000 kips / in.
4.)This Clamp is compatible with B-P Parts 2015,2250,2252,2525 and 2530.
* 5.) Torque Q tolerance = +l'10o/o

ORDERING INSTRUCTIONS :

Specify: Part Number, CDRS Revision Number, and Pipe Size'

EXAMPLE: 61754-R/0-8"

PARr N0. 6175.4


BERG EN POWER PIPE SUPPORTS, INC,
tit t, d
H
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

YOKE CLAMP RESIM"VT . PART NUMBER 6175.7K

"1D- ar- 10'

DIRECTION
OF
LOADING

+
I

t Temperature: 6sooF

No"'
Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition,

Operating Gonditions Test Condition


Size Design Condition (see Notel
Level A Level B Level G Level D
3 7,000 7,000 9,310 10,500 11,060 9.310
4 7,000 7,000 9,310 10,500 11,060 9.310
5 7,000 7,000 9,310 10,500 11,060 9,310
6 7,000 7,000 9.310 10,500 11,060 9,310
8 7,000 7,000 9,310 10,500 11,060 9,310
10 7,000 7,000 9,310 10,500 11.060 9,310
12 7,000 7,000 9,310 10,500 11,060 9,310
14 7,000 7,000 9,310 10,500 11,060 9.310
t6 7,000 7,000 9,310 10,500 11,060 9,310
18 7,000 7.000 9,310 10,500 11,060 9,310
20 7,000 7,000 9,310 10,500 11,060 9,310
24 7,000 7,000 9,310 10.500 11,060 9,310
30 7,000 7,000 9,310 10,500 11.060 9,310
Rated Loads (lbs) tor C/asses 1,2,3 &MC

I cerlify this CDRS mmplies with he CONTROLREFNO. 6175


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports, Inc.
Studs: NiA
Product Engineering Department
Exempt Cotters, Washers, Retainers, Shims (NF-2121)
REV|St0NS
/il Oriqinal lssue 1 0/27109 /3\
e4'kr(.U'e A /t\
/J
s1n lopz/ol lsrcNED /^
BERGEfV POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REV.
A PART NO. 6175.7
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESTRAI'VT . PART NUMBER 6175.7K

t_
I
D

t I

*Q
PIPE SIZE c D E IJ P
FT.LBS
T

3 6 314 1 1t4 I 7t8 314 125 13t4


4 7 314 1 1t4 81t2 7t8 3t4 125 1314
6 9718 1114 9 9/16 718 3t4 125 13t4
8 11718 11t4 10 9/16 7t8 314 125 13t4
10 14 11t4 11518 7t8 3t4 125 13t4
12 16 11t4 12518 7t8 314 125 13t4
14 17 114 1 1t4 13114 7t8 314 125 13t4
16 19114 1 1t4 14114 7t8 3t4 125 13t4
18 21114 11t4 15114 7t8 3t4 125 1314
20 231t4 1 1t4 16114 7t8 3t4 125 1314
24 27 114 1 1t4 18114 7t8 3t4 125 13t4
30 33114 1 114 23114 7t8 3t4 125 13t4

1.) All dimensions are in inches.


2,) Dimensions are provided for user application only'
3.) Minimum spring rate by test = 1500 kips / in.
4.)This Clamp is compatible with B-P Parts 2250,2252,2420,2440,2525 and 2530'
* 5,) Torque Q tolerance = +l- 10o/o

ORDERING INSTRUCTIONS :
Specify: Paft Number, CDRS Revision Number, and Pipe Size'

DGMPLE: 6175-7-R/0-B'

inal lssue 10127109

SHEET 1 OF PART N0. 6175-7


BERGEN POWER PIPE SUPPORTS, 1

'NC.
titr, ffif
E
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

YOKE CUMP RESTRA'TVT . PART NUMBER 617&12K


,-1f'- -1f-'- 10"

DIRECTION
OF
LOADING

I
I

I Temperature: 6sooF

*ottt
,0r, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operating Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
3 12,000 12,000 15.960 18,000 18,960 15,960
4 12,000 12,000 15,960 18.000 18,960 15,960
5 12,000 12.000 15,960 18.000 18.960 15,960
6 12,000 12,000 15,960 18,000 18,960 15,960
I 12,000 12,000 15,960 18,000 18,960 15,960
10 12,000 12,000 15,960 18,000 18,960 15,960
12 12,000 12,000 15,960 18,000 18,960 15,960
14 12,000 12,000 15,960 18,000 18,960 15,960
16 12,000 12,000 15,960 18.000 18,960 15,960
18 12,000 12,000 15,960 18,000 18,960 15,960
20 12,000 12,000 15,960 18,000 18,960 15,960
24 12,000 12,000 15,960 18,000 18,960 15,960
30 12,000 12,000 15,960 18,000 18,960 15,960
Rated foads (lbs) for C/asses 1,2,3 &MC

I certify this CDRS complies wih he CONTROLREFNO. 6175


rcquirements of the applicaHe code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 3A-564 TYP 630
Bergen Power Pipe SuPqorts,lnc,
Studs: N/A
Produc't Engineering Department
Exemptfotters, Washers, Retainers, Shims (N F-2 1 21 )

REVISIONS
/i' Oriqinal lssue 1 0/27109 /3\
t4;qft.4,e /T /A
$EAL Va/22/a?lslGNED /^ /s\

BERGEN POWER PIPE SUPPORTS, SHEET 1 0F 1 REv. a PART N0. 6175.12

''VC.
CDRS CATALOG INFORMATION SHEET

YOKE CLAIIIP RESTRA'NT . PART NUMBER 6175.12K

i
1[-10"
ir

I
I
i I
l<_ T

*Q
PIPE SIZE c D E G P
FT.LBS
T

3 63t4 1 114 I 7t8 3t4 125 1314

4 7 314 11t4 81t2 7t8 3t4 125 13t4


6 97t8 1 1t4 I 9/16 7t8 3t4 12s 13t4
I 11718 1 114 10 9/16 7t8 3t4 125 13t4
10 14 11t4 11 5/8 7t8 3t4 125 13t4
12 16 11t4 125t8 7t8 3t4 125 13t4
14 17 114 1 114 13114 7t8 3t4 125 13t4
16 191t4 1 1t4 141t4 7t8 3t4 125 13t4
18 21114 1 1t4 15114 7t8 3t4 125 1314
20 23114 11t4 161t4 7t8 3t4 125 1314
24 27 114 1 114 181t4 7t8 3t4 125 13t4
30 33114 1 1t4 23114 7t8 3t4 125 13t4
NOTES:
1.) All dimensions are in inches.
2,) Dimensions are provided for user application only'
3.) Minimum spring rate by test = 1500 kips / in.
4.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530.
* 5.) Torque Q tolerance = +l- 10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

EMMPLE: 6175-12-R/0-8"

REVISIONS

PART NO. 6175-12


BERGEN POWER PIPE SUPPORTS,
'NC.
ti/It d
Y
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CLAMP RESTRA'IVT - PART NUMBER 6175.25K

-1f- -1r.-- 10'

DIRECTION
OF
LOADING

I
I

I
Temperature: 6sooF

nott'
For' the test condition (Hydro)the maximum temperature is 100oF. For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition,

Operating Gonditions Test Condition


Size Design Condition
Level A Level B Level G Level D {see Note}
6 25,000 25,000 33,250 37,500 39,500 33,250
8 25,000 25.000 33,250 37,500 39,500 33,250
10 25,000 25,000 33,250 37,500 39,500 33,250
12 25,000 25,000 33,250 37,500 39,500 33,250
14 25,000 25,000 33,250 37,500 39,500 33,250
16 25,000 25,000 33,250 37,500 39,500 33,250
18 25,000 25,000 33,250 37,500 39,500 33,250
20 25,000 25,000 33,250 37,500 39,500 33.250
24 25,000 25,000 33,250 37,500 39,500 33,250
30 25,000 25,000 33,250 37,500 39,500 33,250
36 25,000 25,000 33,250 37.500 39.500 33,250
Rated loads (lbs)for C/asses 1,2,3 &MC

I certify this CDRS complies with fte CONTROL REF NO. 6175
requirements ol the applicaFrle code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports, Inc.
Studs: N/A
Product Engineering Department
Exempl Cotters, Washers, Retainers, Shims (NF-2121)
REV|S|ONS
/il, lOriqinal lssue 1 0/27109 /3\
/N /t\
SEAL lta,/zt,/,t f ISIGNED /t\ /A

BERGEfV POWER PIPE SUPPORTS, SHEET 1 OF t REv. a PART NO. 6175.25

'NC,
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESIRA'NT . PART NUMBER 6175.25K

L-l f-
10'

L TJ
i

*Q
PIPE SIZE c D E G P T
FT.LBS
6 10 5/8 2 10 9/16 1 3/8 1 200 21t2
8 125t8 2 11 9/16 1 3/8 1 200 21t2
10 14 314 2 12 5/8 1 3/8 1 200 2112
12 16314 2 13 5/8 1 3/8 1 200 21t2
14 18 2 14 1t4 1 3/8 1 200 2112
16 20 2 15 114 13t8 1 200 21t2
18 22 2 16 114 13t8 1 200 21t2
20 24 2 17 1t4 1 3/8 1 200 21t2
24 28 2 21 114 1 3/8 1 200 21t2
30 34 2 24 114 1 3/8 1 200 2112
36 40 2 27 114 1 3/8 1 200 21t2

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only'
3.) Minimum spring rate by test = 2000 kips / in'
4.)This Clamp is compatible with B-P Parts 2250,2252,2420,2440,2525 and 2530.
* 5.) Torque Q tolerance = +l'100/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

EXAMPLE: 6175-25-R/0-8'

lssue 10/27109

PART N0. 6175-25


BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1
til I' d
b
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CLATIIP RESIRA'IVT . PART NUMBER 6175.35K

'1f.-- 10" -1f'-- 10'

DIRECTION
OF
LOADING

Temperature: 6500F

For the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operatins Conditions Test Condition


Size Design Condition (see Notel
Level A Level B Level C Level D
12 35,000 35,000 46,550 52,500 55,300 46,550
14 35,000 35,000 46,550 52,500 55,300 46,550
16 35,000 35,000 46,550 52,500 55,300 46,550
18 35,000 35,000 46,550 52,500 55,300 46,550
20 35,000 35,000 46,550 52.500 55,300 46,550
24 35,000 35,000 46,550 52,500 55,300 46,550
30 35,000 35,000 46,550 52,500 55,300 46,550
36 35,000 35,000 46,550 52,500 55,300 46,550
Rated Loads (lbs) for C/asses 1,2,3 & MC

I ceftify this CDRS complles wifi the CONTROLREFNO. 6175


rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolh SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 3A-564 TYP 630
Bergen Power Pipe Supports,lnc.
Studs: N/A
Product Engineeilng Department
Eiempt Cotters, Washers, Retainers, Shims (NF-2121)
REVISI0NS
/il\ Orioinal lssue 10/27109 /^
8.jt:.".tr.&6 A /t
sEAt lta/tz/d?ISIGNED /z\ /5\

BERGEII, POWERPIPE SUPPORTS, NC. SHEET 1 0F I REv. a PARTNo. 6175.35


titJ, d
CDRS CATALOG INFORMATION SHEET

-
YOKE CLATTP RESIRA'NT . PART NUFIIBER 6175-35K

*Q
PIPE SIZE c D E t5 P
FT.LBS
T

12 17 1t2 21t2 13 3/8 11t2 1 1t4 600 3

14 18 314 21t2 14 1 1t2 1114 600 3

16 20 314 21t2 15 11t2 11t4 600 3

18 223t4 21t2 16 11t2 11t4 600 3

20 24 314 2112 17 11t2 11t4 600 3

24 28 3t4 2112 20 1112 1 1t4 600 3

30 34 314 2112 24 11t2 1114 600 3

36 40 314 21t2 27 1t4 11t2 11t4 600 3

NOTES:
1.)Alldimensions are in inches.
2.) Dimensions are provided for user application only.
3.) Minimum spring rate by test = 3000 kips / in.
4.)This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530.
* 5.) Torque Q tolerance = +l- 10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

EXAMPLE: 6175-35-R/0-20"

REVISIONS
/i\ I Oriqinal lssue 10127 109 /3\

/1' /i
A /s'

BERGEN POWER PIPE SUPPORTS, NC, SHEET 1 OF 1 REV. A PART N0. 6175.35
tit*L Y
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CUMP RESIRA'IVT . PART NUMBER 6175.60K

-1f-- -1;-_ 10'

DIRECTION
OF
LOADING

I
I

t
Temperature: 6500F

Nott'
Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operatins Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
12 60,000 60,000 79,800 90,000 94,800 79,800
14 60,000 60,000 79,800 90,000 94,800 79,800
16 60,000 60,000 79,800 90,000 94.800 79,800
18 60,000 60,000 79,800 90,000 94,800 79,800
20 60,000 60,000 79,800 90,000 94,800 79.800
24 60,000 60.000 79,800 90,000 94,800 79,800
30 60,000 60,000 79,800 90,000 94,800 79,800
36 60,000 60,000 79,800 90,000 94,900 79,800
Rated Loads (lbs)for Classes 1,2,3 &MC

I certify this CDRS complies with the CONTROLREF NO. 6175


rcquirements of the applicabh code IIATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 5A-564 TYP 630
Bergen Power Prpe Sup porh, lnc,
Studs: N/A
Product Engineering Department
Exempt Cotters, Washers, Retainers, Shims {NF-2121)
REV|St0NS
/i
&.>/,&a /i
#.AL Va/zz/a/lslGNED /i
/o\ Oriqinal lssue 1 0/27109
/r\
/s\

BERGEN POWERPIPE SUPPORTS, NC, SHEET 1 OF 1 REV.


A PART N0. 6175.60
JJ-
trj I'
rd
bd
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESTRN'NT . PART NUMBER 6175.60K

*Q
PIPE SIZE c D E t: P T
FT.LBS
12 181t4 21t2 15 1/8 111116 1112 1000 3112
14 191t2 2112 16 111t16 11t2 1000 31t2
16 211t2 21t2 17 1t4 111116 11t2 1000 3112
18 23112 21t2 181t2 111t16 11t2 1000 3112
20 25112 21t2 19 3t4 111116 11t2 1000 3112
24 291t2 2112 22114 111t16 11t2 1000 31t2
30 35112 2112 26 111116 11t2 1000 3112
36 411t2 2112 29 111t16 1112 1 000 3112

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only'
3.)This Clamp is cornpatible with B-P Parts 2250,2252,2421,2440,2525 and 2530.
* 4.)Torque Q toleranca= +l- 100/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

DGMPLE: 6175-60-R/0-20"

REVISIONS
Al6qrnal lsa ie lOtZt tOg 3

/r\, /N
,/ )\ /s\

BERGEfV POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV.


A PART N0. 6175.60
tit D, d
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CLATtrP RESTRA''VT . PART NUMBER 6175.80K

af-- il'-- to'

DIRECTION
OF
LOADING

I
I

Temperature: 6sooF

Nott'
Fo, the test condition (Hydro)the maximum temperature is 1000F, For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition
Level A Level B Level C Level D {see Note)
12 80,000 80,000 106,400 120,000 126,400 106,400
14 80,000 80,000 106,400 120,000 126,400 106,400
16 80,000 80,000 106,400 120,000 126,400 106,400
18 80,000 80,000 106,400 120,000 126,400 106,400
20 80,000 80,000 106,400 120,000 126,400 106,400
24 80,000 90,000 106.400 120,000 126,400 106,400
30 80,000 80,000 106,400 120,000 126,400 106,400
36 80,000 80,000 106,400 120,000 126,400 106,400
Rated Loads (lbs) for C/asses 1,2,3 & MC

CONTROL REF NO. 6175


I certity ttis CDRS complies with fie
requirements of the applicable ode MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr 70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 3A-564 TYP 630
Bergen Power Pipe SuPPot{g lnc.
Studs: N/A
Product Engineering DePartment
fxernptl Cotters, Washers, Retainers, Shims (NF-z121)
REV|StONS
10/27109 |/i
fuK,&a /d\ Oriqinal lssue
A )
t, J
SEAL ltaAz/o? lslGNED /z\

BERGEAJ POWERPIPE SUPPORTS, INC.


-T $HEET 1 0F I REV.
A PART N0. 6175.80
CDRS CATALOG INFORMATION SHEET

YOKE CLAMP RESTruI'AJT . PART NUMBER 6175.80K

L-
i_ 1l-'o'
r
P

*Q
PIPE SIZE c D E TJ P T
FT.LBS
12 18112 3114 15 3/8 113t16 1314 525 6

14 20 31t4 17 113116 13t4 525 6

16 22 3114 18 113116 13t4 52s 6

18 24 31t4 19 113t16 13t4 525 6

20 26 3114 20 1 13/16 1314 525 6

24 30 31t4 23 113t16 13t4 525 6

30 36 3114 27 1 13/16 13t4 525 6

36 42 31t4 321t2 113t16 13t4 525 6

1,) All dimensions are in inches.


2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Parts 2250, and2252'
* 4.) Torque Q toleranca = +l^ 10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

DGMPLE: 6175-80-R/0-20"

PART N0. 6175.80


BERGEN POWER PIPE SUPPORTS,
'NC.
tit*J, CERTIFIED DESIGN REPORT SUMMARY
for
E
NUCLEAR POWER PLANT STANDARD SUPPORTS

YOKE CLAMP RESTRA'IVT . PART NUMBER6175.13OK

ar- -1l-- 10"

DIRECTION
OF
LOADING

i
I

i Temperature: 6500F

*ottt
,0, the test condition (Hydro) the maximum temperature is 100oF, For higher
Design Spec. No. D96175
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6175
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
14 130,000 130,000 172,900 195,000 205,400 172,900
16 130,000 130,000 172,900 195,000 205,400 172,900
18 130,000 130,000 fi2,904 195,000 205,400 172,900
20 130,000 130,000 fi2,904 195,000 205,400 172,900
24 130,000 130.000 172,900 195,000 205,400 172,900
30 130,000 130,000 172,900 195,000 205,400 172,900
36 130,000 130,000 172,900 195,000 205.400 fi2,904
Rated Loads (lbs) for Classes 1,2,3 & MC

I certify this CDRS complies with fie CONTROLREFNO. 6175


requirements of the applicabb code MATERIALS
The Design Report & Design Specification are in
Yoke: SA-515 Gr70
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: 3A-564 TYP 630
Bergen Power Ptpe Supports,lnc.
Studs: N/A
Product Engineering DePartment
Exempt Cotters, Washers, Retainers, Shims (NF-2121)
REVISIONS
/il Orioinal lssue 10/27109 )
*-rfu K,&& A l/4\
$F/rt Vo/zt /ct? lslGNED /i A

BERGEN POWER PIPE SUPPORTS, INC,


--_1, SHEET 1 0F 1 REV.
A PART NO. 6175.130
jJ-
,rl I, CDRS CATALOG INFORMATION SHEET
4
-/
YOKE CLAMP RESIRII'NT . PART NUMBER 6175.130K

*Q
PIPE SIZE c D E t P T
FT.LBS
14 20 4 19 2 1t16 2112 835 I
16 22314 4 20 2 1t16 21t2 835 I
18 25 4 21 2 1t16 2112 835 I
20 27 4 23 2 1t16 21t2 835 I
24 31 4 25 2 1116 21t2 835 8

30 37 4 29 2 1t16 21t2 835 I


36 43 4 32 2 1116 21t2 835 I

1,) All dimensions are in inches.


2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Parts 2250,2252,2421and2440.
* 4,) Torque Q toleran ca = +l' 10o/o

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

EXAMPLE: 6175-130-R/0-20"

REVISIONS
/N I Orioinal lssue 10127 109 /i
/ 1\ /A
l)
/s\

BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV.


A PART N0. 6175-130
jJ- CERTIFIED DESIGN REPORT SUMMARY
,TJ
*J,
for
d
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP for SIRUIS by P.S.C. - PART NUMBER 6202-,35k

DIRECTION
OF
LOADING

I
I
I

t Temperature: 6500F

Nott'
For, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D$6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
31,4 350 350 466 525 658 466
I 350 350 466 525 658 466
1114 350 350 466 525 658 466
1112 350 350 466 525 658 466
2 350 350 466 525 658 466
21t2 350 350 466 525 658 466
3 350 350 466 525 658 466
4 350 350 466 525 658 466
5 350 350 466 525 658 466
6 350 350 466 525 658 466
8 350 350 466 525 658 466
10 350 350 466 525 658 466
Rated Loads (lbs) for C/asses 1,2,3 & MC

*
Use only with mechanicalstruts manufactured by Pacific Scientific Co. per Bulletin PSA4

I certify this CDRS mmplies with he CONTROL REF NO. 6202


rcquirements of the applicabh code MATERIALS
The Design Report & Design Specification are in
>late: 3A-36
accordance with ASME BPVC Section lll, Subsection
Solts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 GrA
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports, lnc.
Studs: SA-36
Product Engineering Department
Eiempt Cotter pins, Washers, Retainers (NF-2121)
REV|SIONS
/; Orioinal lssue 1 0/27109 /t\
8,9tk 14,46. I /r\
5E L Vo/zt/o? lslGNED /^ /i
BERGEAJ POWER PIPE SUPPORTS, INC. SHEET 1 0F I REV.
A PART N0. 6202..35
CDRS CATALOG INFORMATION SHEET

ptPE 1LAMP for SIRUIS by P,S.C, - PART NUMBER 6202-,35k

10'

_l
I

STOCK
PIPE SIZE D E u P S
TxW
3t4 5/8 41t4 13t32 3/8 1 5/8 114x1 112
1 5/8 4112 13t32 3/8 1718 114x1112
11//4 5/8 43t4 13t32 3t8 21t8 114x1112
1112 5/8 4314 13132 3/8 21t4 114 x1 112

2 5/8 5 13t32 3/8 2 9116 114x1112


2112 5/8 5 314 13t32 3/8 2718 114x1112
3 5/8 6 13t32 3/8 3114 114 x1 112

4 5/8 7 13t32 3/8 3314 114x1112


5 5/8 71t2 13t32 3/8 4 3t8 114x1112
6 5/8 8 13t32 3/8 4718 114x1112
I 5/8 91t2 13t32 3/8 57t8 114 x2
10 5/8 11 13t32 3/8 7 118 114 x2

1.) All dimensions are in inches' :

2.) Dimensions are provided for user application only'


3,)This Clamp is compatible with PSA 1/4'
place.
4,) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock in

ORDERING INSTRUCTIONS:
specify: Part Number, oDRS Revision Number, and Pipe size.

D(AMPLE: 6202-.35-R/04"

ioinal lssue 10127109

PART N0. 6202-.35


BERG EN POWER PIPE SUPPORTS, INC,
lit f' d
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CIAIIIP for SIRUIS by P,S.C, - PART NUMBER 6202-,65k

DIRECTION
OF
LOADING

I
I

I
I

i Temperature: 6sooF

Nott'
For, the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. D$6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. PR-6202
shown for the Operating Condition.

Operating Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
314 650 650 865 975 1,221 865
1 650 650 865 975 1,221 865
11t4 650 650 865 975 1,221 865
11//2 650 650 865 975 1,221 865
2 650 650 865 9i5 1,221 865
21t2 6s0 650 865 975 1,221 865
3 650 650 865 9i5 1,221 865
4 650 650 865 975 1,221 865
5 650 650 865 975 1,221 865
6 650 650 865 975 1,221 865
I 650 650 865 975 1,221 865
10 650 650 865 975 1,221 865
Ratedloads (lbs)for Classes 1,2,3 &MC

*
Use only with mechanicalstruts manufactured by Pacific Scientific Co. per Bulletin PSA4

I certify this CDRS complies with the CONTROLREFNO. 6202


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 54-564 TYP 630
Bergen Power Pipe Supports,lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISIONS
/l Orioinal lssue 10/27109 /t\
8.ti*/,&fr, /il /i
sEAt lta/92/a9lslGNED /^ /5\

BERGEAJ POWERPIPE SUPPORTS, NC, SHEET 1. OF 1 REV.


A PART N0. 6202..65
CDRS CATALOG INFORMATION SHEET

P|PE CLAMP for STRIIIS by P.S.C. ' PART NUMBER 6202'.65k

10"

Ih-,ru
G-:r
ilrl
]'

STOCK
PIPE SIZE D E u P s
TxW
3t4 5/8 41t4 13t32 3/8 1 5/8 114x1112
1 5/8 4112 13t32 3/8 1718 114 x1 112

1tt4 5t8 4314 13132 3/8 21t8 114 x1 112

1112 5/8 43t4 13t32 3i8 21t4 114 x 1 112

2 5/8 5 13132 3i8 2 9116 114 x I 112

2112 5/8 5 314 13t32 3/8 2718 114 x I 112

3 5/8 6 13t32 3/8 3114 114 x1 112

4 5/8 7 13132 3/8 3 3t4 114 x1 112

5 5/8 7112 13t32 3/8 4 318 114 x1 112

6 5/8 I 13t32 3/8 47t8 114 x 1 112

I 5/8 9112 13t32 3/8 57t8 114 x2


10 5/8 11 13132 3/8 7 1t8 114 x2

1.) All dimensions are in inches.


2.) Dimensions are provided for user application only.
3,)This Clamp is compatible with PSA 1/2'
4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place'

ORDERING INSTRUCTIONS:
specify: Part Number, CDRS Revision Number, and Pipe size.

E)(AMPLE: 6202-.65-R/04"

REVISIONS
inal lssue 10127109

PART N0. 6202..65


BERGE'\' POWER PIPE SUPPORTS, INC, SHEET 1 OF 1
tit d
b
,,
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CLAMP for SIRUIASSEMBT,ES - PART NUMBER 6202-,7k

DIRECTION
OF
LOADING

Temperature: 6500F

No"'
For" the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No, D96202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operatins Conditions Test Condition


Size Design Condition
Level A Level B Level C Level D {see Note}
3t4 750 750 998 1,125 1,409 998
1 750 750 998 1,125 1,409 998
1114 750 750 998 1,125 1,409 998
1112 750 750 998 1.125 1,409 998
2 750 750 998 1,125 1,409 998
21//2 750 750 998 1,125 1,409 998
3 750 750 998 1,125 1,409 998
4 750 750 998 ,125 1,409 998
5 750 750 998 1.125 1,409 998
6 750 750 998 1,125 1,409 998
8 750 750 998 1,125 1.409 998
10 750 750 998 1,125 1,409 998
Rated Loads (lbs) for C/asses 1,2,3 &MC

I certify this CDRS complies with he CONTROL REF NO. 6202


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 54-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports, lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-2121)
REV|S|ONS
/o\ Oriqinal lssue 1 0/27109 /i
e'4t>K,&..6, 1 /r\
sEAr- lta/az/a / ISIGNED 2 /c

BERGEN POWER PIPE SUPPORTS, INC, sHEETloFl I nev. A PART N0. 6202..7
CDRS CATALOG INFORMATION SHEET

PIPE CLAMP fOT SIRUTASSEMBT'ES . PART NUMBER 6202-.7K

STOCK
PIPE SIZE D E tt P s
TxW
3t4 5/8 41t4 17t32 3/8 1 5/8 114 x1 112

1 5/8 4112 17t32 3/8 17t8 114 x1 112

1114 5/8 4 3t4 17t32 3/8 2118 114 x1 112

11t2 5/8 4 3t4 17t32 3/8 21t4 114x1112


2 5/8 5 17t32 3/8 2 9t16 114 x1 112

21112 5/B 5 3t4 17t32 3/8 2718 114 x1 112

3 5/8 6 17t32 3/8 3114 114 x1 112

4 5/8 7 17t32 3/8 33t4 114 x1 112

5 5/8 71t2 17t32 3/8 4 3t8 114 x1 112

6 5/8 I 17t32 3/8 47t8 114 x1 112

I 5/8 9112 17t32 3/8 57t8 114x2


10 5/8 11 17t32 3/8 7 1t8 114xZ
NOTES:
' L ) All dimensions are in inches.
2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Pads 2015,2250,2252,2440 and2420'
4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place.

ORDERING INSTRUCTIONS :

Specify: Part Number, CDRS Revision Number, and Pipe Size.

EMMPLE: 6202'J'N04'
REVISIONS

PART N0, 6202..7


BERGEN POWER PIPE SUPPORTS, INC.
titJ' d
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CUMP for SIRUI ASSEMBTTES - PART NUMBER 6202'1.sk

DIRECTION
OF
LOADING

Temperature: 650'F

no"'
Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Repoil No, DR-6202
shown for the Operating Condition,

Operating Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
314 1,500 1,500 1,995 2,250 2,819 1,995
1 1,500 1,500 1,995 2,250 2,819 1,995
11t4 1,500 1,500 1.995 2,250 2,819 1,995
1112 1,500 1,500 1,995 2,250 2,819 1,995
2 1,500 1,500 1,995 2,250 2,819 1,995
21t2 1,500 1,500 1,995 2,250 2,819 1,995
3 1,500 1,500 1.995 2,250 2,919 1,995
4 1,500 1,500 1.995 2,250 2,819 1.995
5 1,500 1,500 1.995 2,250 2,819 1,995
6 1,500 1,500 1,995 2,250 2,819 1,995
I 1,500 1,500 1,995 2,250 2.819 1,995
10 1,500 1,500 1,995 2,250 2,819 1,995
12 1,500 1,500 1,995 2,250 2,819 1,995
Rated Loads (lbs) for C/asses 1,2,3 &MC

I certifl this CDRS complies with the CONTROL REF NO. 6202
requiremenb ol the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe SupPorts, Inc.
Studs: SA-36
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISIONS
/i 0riqinal lssue 1 0/27109 /3\
/r-.>,&,il*fr- /t
#.AL Va/zzlot lslGNED /z\ /s\

BERGEA' POWERPIPE SUPPORTS, INC. SHEET 1 0F 1 REv.


a PART N0. 6202.1.5
CDRS CATALOG INFORMATION SHEET

P|PE CLAMP for STRTJIASSEMBLTES ' PART NUMBER 6202'1,5k

STOCK
PIPE SIZE D E ^*
st P s
TxW
3ii4 3t4 41t4 21t32 1t2 17t8 114 x2
1 3t4 41t2 21t32 1t2 21t8 114 x2
1114 314 4314 21132 1t2 23t8 114 x2

1112 3t4 4314 21132 1t2 25t8 114 x2

2 3t4 5 21t32 1t2 3 114x2


2112 3t4 5314 21t32 1t2 31t4 114 x2
3 314 6 21t32 1t2 31t2 114x2
4 3t4 7 21132 1t2 4114 3lB x2
5 3t4 7 112 21t32 1t2 413116 318x2
6 314 I 21132 1t2 s 3/8 318x2
I 3t4 9112 21t32 1t2 6 3/8 318x2
10 3t4 11 21t32 1t2 7 318 318x2
12 3t4 12 21132 1t2 8 5/8 112x2
NOTES:
1.) All dimensions are in inches'
2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Parts 2015,2250,2252,2440 and2420.
place.
4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in
* 5.) when used with PSA-1'
G = 112",

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Pipe Size and "G" Dimension'

EMMPLE: 6202-1.5-R/04' G= 21132"

ioinal lssue 10127109

PART N0. 6202-1.5


BERG EN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1
tit f' *
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CUMP for SIRUTASSEMBT,ES . PART NUMBER 6202-4k

I
DIRECTION
OF
LOADING

Temperature: 6500F

Nottt
Fol, the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Gonditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
2112 4,000 4,000 5,320 6,000 7,516 5,320
3 4,000 4,000 5,320 6,000 7,516 5,320
4 4,000 4,000 5,320 6,000 7,516 5,320
5 4,000 4,000 5,320 6,000 7,516 5,320
6 4,000 4,000 5,320 6,000 7,516 5,320
E 4,000 4,000 5,320 6,000 7,516 5,320
10 4,000 4,000 5,320 6,000 7,516 5,320
12 4,000 4,000 5,320 6,000 7,516 5,320
14 4,000 4,000 5,320 6,000 7,516 5,320
16 4,000 4,000 5,320 6,000 7,516 5,320
18 4,000 4,000 5,320 6,000 7,516 5,320
20 4,000 4,000 5,320 6,000 7,516 5,320
24 4,000 4,000 5.320 6,000 7,516 5,320
30 4,000 4,000 5,320 6,000 7,516 5,320
36 4,000 4,000 5,320 6,000 7,516 5,320
Rated Loads ilb$ for Classes 1,2,3 &MC
I certify this CDRS complies with the
CONTROLREFNO. 6202
rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 GrA
Pin: 3A-564 TYP 630
Bergen Power Pipe SuPqorts,lnc.
Studs: SA-36
Product Engineering DePartment
Exempt Cottei pins, Washers, Retainers (NF-2121)
REVIStONS

/; Orioinal lssue 10/27109 /3\

futuK,aur,a A /A
SEAL I ISIGNED /z\ /s\

BERGEN POWER PIPE SUPPORTS, INC. SHEET 1 0F I REV.


A PART N0. 6202-4
tijT, d
E
CDRS CATALOG INFORMATION SHEET

PIPE CIAMP fOr SIRUIASSEMBT'ES . PART NUMBER 6202.4K

IG;
L---_l I

STOCK
PIPE SIZE D E G P s
TxW
2112 7t8 71t4 21t32 1t2 41t4 518 x2-112
3 7t8 7 3t4 21t32 1t2 41t2 518 x2-112
4 7t8 81t4 21t32 1t2 5 1/8 518x2-112
5 718 8314 21t32 1t2 53t4 5/8x3
6 7t8 91t2 zil32 1t2 6 3/8 5/8x3
I 7t8 101t2 21t32 1t2 7 3t8 5/8x4
10 7t8 12 21t32 1t2 81t2 518 x4

12 7t8 13 21t32 1t2 9718 5/8x5


14 7t8 14 21132 1t2 10 5/8 314 x4

16 7t8 15 21t32 1t2 11518 314 x4

18 7t8 16 21t32 1t2 125t8 314x4-112


20 7t8 17 21t32 1t2 13 314 3/4x5
24 7t8 19 21t32 1t2 16118 1x4-112
30 7t8 23 21t32 1t2 19114 1x4-112
36 7t8 26 21t32 1t2 22114 1x5
NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Parts 2015,2250,2252,2525 and 2530'
4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock in place.

ORDERING INSTRUCTIONS:
specify: Part Number, CDRS Revision Number, and Pipe size,

DGMPLE: 6202-4-R/04"

REVISIONs
Albrtqrnal tssue t OlZZlOg /s\
/1' /A
/r\ /N

BERG EN POWER PIPE SUPPORTS, INC, SHEET L 0F l- REV.


A PARr N0. 6202-4
tit r, d
E
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CUMP for SIRUIS by P.S,C. - PART NUMBER 6202-6k

DIRECTION
OF
LOADING

Temperature: 6500F
V

Nott'
For' the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Repoil No. DR-6202
shown for the Operating Condition.

OperatinE Gonditions Test Condition


Size Design Condition (see f.lotel
Level A Level B Level C Level 0
3 6,000 6,000 7,980 9,000 11,274 7,980
4 6,000 6,000 7,980 9.000 11.274 7,980
5 6,000 6,000 7.980 9,000 11,274 7.980
6 6,000 6,000 7,990 9.000 11.274 7.980
E 6,000 6,000 7,990 9,000 11,274 7,980
10 6.000 6,000 7,980 9,000 11,274 7,980
12 6,000 6.000 7,980 9,000 11,274 7,980
14 6,000 6,000 7,980 9,000 11,274 7,980
16 6,000 6,000 7,980 9,000 11,274 7,980
18 6,000 6,000 7,980 9,000 11,274 7,980
20 6,000 6,000 7,980 9,000 11,274 7,980
24 6,000 6,000 7,980 9,000 11,274 7,980
30 6,000 6.000 7,980 9,000 11,274 7,980
36 b,000 6,000 7,980 9,000 11,274 7,980
Rated Loads (lbs)for C/asses 1,2,3 &MC
*
Use only with mechanical struts manufactured by Pacific Scientific Co. per Bulletin PSA4

I certify this CDRS complies with the CONTROLREFNO. 6202


requhements of tte applicable code [IATERIALS
The Design Report & Design Specification are in
Plate: 34-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 GrA
Pin: 5A-564 WP 630
Bergen Power Pipe Supporfg lnc.
Studs: 34-36
Product Engineering Depailment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISIONS

AlOriginal lssue 10/27109 ll/J


E-i-"K,&.ffi AI-
#,nr l/a/zz/as lslGNED /)
7, t, J
i

BERGETV POWER PIPE SUPPORTS, NC. SHEET 1 0F 1 REV.


A PARTN0. 6202.6
CDRS CATALOG INFORMATION SHEET

P|PE CLAMP for SIRUIS by P.S.C' ' PART NUMBER 6202-6k


10'

c-]l
ffi, W

STOCK
PIPE SIZE D E G P S
TxW
3 11t8 7 314 13132 314 4112 518 x2-112
4 1 1t8 8114 13t32 314 5 1/8 518 x2-112
5 11t8 I314 13t32 3t4 5314 5/8x3
6 11t8 9112 13t32 314 6 3/8 5/8x3
I 11t8 10112 13t32 314 7 318 518x4
10 1118 12 13t32 3t4 8112 5/8x4
12 11t8 13 13t32 3t4 g7t8 5/8x5
14 11t8 14 13t32 314 10 5/8 314x4
16 11t8 15 13132 3t4 11 5/8 314x4
t8 11t8 16 13132 3t4 125t8 314 x4-112
20 11t8 17 13132 3t4 13 3t4 3/4x5
24 11t8 19 13t32 3t4 161/8 1x4-112
30 11t8 23 13t32 3t4 191t4 1x4-112
36 1118 26 13t32 3t4 221t4 1x5
NOTES:
1.) All dimensions are in inches'
2')Dimensionsareprovidedforuserapplicationonly'
3.)This Clamp is compatible with PSA-3
place.
4.) lnstallation: Tension bolts to remove slack, plus 1l2lum of nut, then lock in

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

EXAMPLE: 6202-6-R/04-

al lssue 10127109

BERGEN POWER PIPE SUPPORTS, INC.


tltI' ffiJ
ry
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP for STRUIASSE?|BLIES - PART NUMBER 6202-7k

I DIRECTION
l
I
OF
LOADING

Temperature: 6500F
I
Nott'
Fol. the test condition (Hydro)the maximum temperature is 100"F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

0peratino Conditions Test Gondition


Size Design Condition
Level A Level B Level G Level D (see Note)
3 7,000 7,000 9,310 10,500 13,153 9,310
I 7,000 7,000 9,310 10,500 13,153 9,310
5 7,000 7,000 9.310 10,500 13,153 9,310
6 7,000 7,000 9,310 10,500 13,153 9,310
8 7.000 7,000 9,310 10,500 1 3,1 53 9,310
t0 7,000 7,000 9,310 10,500 13,153 9,310
12 7,000 7,000 9,310 10,500 1 3.1 53 9.310
14 7,000 7,000 9,310 10,500 13,153 9,310
16 7,000 7,000 9,310 10,500 13,153 9,310
18 7,000 7,000 9,310 10,500 13,153 9,310
20 7,000 7,000 9,310 10,500 1 3,1 53 9,310
24 7,000 7,000 9,310 10,500 13,153 9,310
30 7,000 7,000 9,310 10.500 1 3,1 53 9,310
36 7,000 7,000 9,310 10,500 13,153 9.310
Rated Loads (lbs)for Classes 1,2,3 & MC

I certify this CDRS mmplies with $e CONTROL REF NO. 6202


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe Supports, lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-2121)
REV|StONS
/il lOrioinal lssue $127109 /s\
t4rbK,d*fr /t\ /t
*.AL lta/qz/dq ISIGNED /z\ /i
BERGETV POWER PIPE SUPPORTS, NC, sHEErl 0F I REV.
A PART NO. 6202.7
ti7 T, FJ
E
CDRS CATALOG INFORMATION SHEET

PIPE CLAMP fOr SIRUT ASSEMBI'ES . PART NUMBER 6202.7K

STOCK
PIPE SIZE D E u P s
TxW
3 1 1t4 7 314 29t32 3t4 4 3t4 5/8x5
4 1t4 8114 29t32 3t4 51t4 5/8x5
5 1 114 8314 29t32 3t4 6 5/16 718 x4-112

6 1 1t4 9112 29t32 3t4 67t8 718x4-112


I 1114 101t2 29t32 3t4 I 718x4-112
10 1 1t4 12 29132 314 I 5/16 1x5
12 1114 13 29t32 3t4 10 3/8 1x5
14 1 1t4 14 29t32 314 111t4 1x5
16 1 114 15 29132 3t4 12114 1x5
18 1114 16 29132 3t4 131t4 1x5
20 1114 17 29132 3t4 14114 1x5
24 1114 19 29132 3t4 16 3t4 1xO
30 1 114 23 29ts2 314 20 1-114 x6
36 1 1t4 26 29t32 3t4 23 1-114 xE

1.) All dimensions are in inches.


2.) Dimensions are provided for usrir application only'
3.) This Clamp is compatible with B-P Parts 2250,2252,2440 and2420'
4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place'

ORDERING INSTRUCTIONS:
specify: Part Number, 0DRS Revision Number, and Pipe size.

DGMPLE: 6202-7-N0-4'

REVISIONS

/N Oriqinal lssue 1 0/27109 /t\


/a\
/^ /s\

BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV.


A PART N0. 6202-7
J,-
tJl CERTIFIED DESIGN REPORT SUMMARY

d
H
r, for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CLAMP for SIRUI ASSEIfBIIES - PART NUMBER 6202-12k

_l DIRECTION
OF
I

LOADING

Temperature: 6500F

Nott'
For the test condition (Hydro) the maximum temperature is 100oF. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
3 12,000 12,000 15,960 18,000 22,U8 15,960
4 12,000 12,000 15,960 18.000 22,548 15,960
5 12,000 12,000 15,960 18.000 22,548 15,960
6 12,000 12,000 15,960 18,000 22,548 15,960
I 12,000 12,000 15,960 18,000 22,548 15.960
10 12,000 12,000 15,960 18,000 22,548 15,960
12 12,000 12,000 15,960 18,000 22,548 15,960
14 12,000 12,000 15,960 18,000 22,548 15,960
16 12,000 12,000 15,960 18.000 22,548 15,960
18 12,000 12,000 15,960 18,000 22,548 15,960
20 12,000 12,000 15,960 18,000 22,548 15,960
24 12,000 12,000 15,960 18,000 22,548 15,960
30 12,000 12,000 15.960 18,000 22,548 15,960
36 12,000 12,000 15,960 18,000 22,548 15,960
Rated loads (lbs) for C/asses 1,2,3 &MC

I certify this CDRS complies with the CONTROLREFNO. 6202


requirements of the apflicable ode MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 3A-563 Gr A
Pin: 5A-564 WP 630
Bergen Power Pipe Suppotts,lnc.
Studs: SA-36
Product Engineering Department
Eiempt Cotter pins, Washers, Retainers (NF-2121)
REV|StONS
/il Oriqinal lssue 0127/09 /^
LhK,&.fr,
1

A A
9EAL Va/z2/oflSlGNED /i /i
BERGETI, POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV. A PART N0. 6202.12
JJ-,
,lJ r,
#l
CDRS CATALOG INFORMATION SHEET

-
PIPE CUMP fOT SIRUIASSEMBI.'ES - PART NUMBER 6202.12K

t-

c STOCK
PIPE SIZE D E G P
TxW
3 1114 7 3t4 29t32 3t4 4 3t4 5/Bx5
4 1114 81t4 29t32 3t4 51t4 5/8x5
5 1 1t4 8 3t4 29t32 3t4 6 5/16 718 x4-112

6 1 1t4 9112 29t32 3t4 6718 718 x4-112


8 1 1t4 10112 29t32 3t4 8 718 x4-112

10 1 1t4 12 29t32 3t4 I 5/16 1x5


12 1 114 13 29132 3t4 10 3/8 1x5
14 1 114 14 29t32 3t4 111t4 1x5
16 11t4 15 29132 3t4 12114 1x5
18 11t4 16 29t32 314 131t4 1x5
20 1 1t4 17 29t32 3t4 141t4 1x5
24 1 1t4 19 29t32 3t4 16 3/4 1x6
30 1 1t4 23 29t32 3t4 20 1-114 x6

36 1 1t4 26 29t32 3t4 23 1-114 x6


NOTES:
' 1,) All dimensions are in inches.
. 2.) Dimensions are provided for user application only.
3.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530.
4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place.

ORDERING INSTRUCTIONS :
Specify: Part Number, CDRS Revision Number, and Pipe Size'

D(AMPLE: 6202-12-N04'

REVISIONS
/N I Oriqinal lssue 10127 109 /i
iil /4\
/o\ /5'

BERGEN POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV. A PART N0. 6202-12
ti| J' d
k
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CLAMP for SIRUIS by P.S.C. - PART NUMBER 6202'15k

I
DIRECTION
OF
LOADING

Temperature: 6500F

Nott'
For the test condition (Hydro) the maxirnum temperature is 1000F. For higher
Design Spec. t{o. D96202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D

3 15,000 15,000 19,950 22,500 28,185 19,950


4 15,000 15,000 19,950 22,500 28,185 19,950
5 15,000 15,000 19,950 22,500 28,185 19,950
6 15,000 15,000 19,950 22,500 28,185 19,950
8 15,000 15,000 19.950 22,500 28,185 19,950
10 15,000 15,000 19,950 22,500 28,185 19,950
12 15,000 15,000 19,950 22,500 28,185 19,950
14 15,000 15,000 19,950 22,500 28,185 19,950
16 15,000 15,000 19,950 22,500 28,185 19,950
18 15,000 15,000 19.950 22,500 28,185 19,950
20 15,000 15,000 19,950 22,5A0 28,185 19,950
24 15,000 15.000 19,950 22,500 28,185 19,950
30 15,000 15,000 19,950 22,540 28,185 19,950
36 15,000 15,000 19,950 22,500 28,185 19,950
Rated Loads (lhs) for C/asses 1,2,3 & MC
*
Use only with mechanical struts manufactured by Pacific Scientific Co. per Bulletin PSA4

I certify this CDRS complies with the


CONTROLREFNO. 6202
requirements ol the appfrcable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 GrA
Pin: S4-564 TYP 630
Bergen Power Pipe SuPPorts,lnc.
Studs: SA-36
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISI0NS
/N 0riqinal lssue 10/27109 it
&->,tr,U"fr A 4\
SEAL lz/zz/a9 ISIGNED /^ /s\

BERGEAJ POWER PIPE SUPPORTS, INC. SHEET 1 0F I REv. a PART N0, 6202.15
CDRS CATALOG INFORMATION SHEET

ptPE 1LAMP for SIRUIS by P.S.C. - PART NUMBER 6202-15k

STOCK
PIPE SIZE D E t, P S
TxW
3 11t4 7 314 1 3132 I 5 1/8 5/8x5
4 11t4 8114 1 3132 1 5114 5/8x 5

5 1114 8 3/4 1 3t32 1 6 5/16 718 x4-112

6 1 114 91t2 1 3132 1 6718 718 x4-112

8 1 1t4 10112 1 3132 1 8 718 x4-112

10 11t4 12 1 3t32 1 I 5/16 1x5


12 1 1t4 13 1 3t32 1 10 3/8 1x5
14 1114 14 1 3132 1 11114 1x5
16 1 1t4 15 1 3132 1 12114 1x5
18 1114 16 1 3132 1 13114 1x5
20 11t4 17 1 3t32 1 14114 1x5
24 11t4 19 1 3132 1 16 314 1x6
30 11t4 23 1 3t32 1 20 1-114 x6
36 11t4 26 1 3t32 1 23 1-114 x6

1.)Alldimensions are in inches'


2.) Dimensions are provided for user application only'
3,)This Clamp is compatible with PSA-10
in place.
4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then lock

ORDERING INSTRUCTIONS:
specify: Part Number, 0DRS Revision Number, and Pipe size.

DGMPLE: 62a2-15-R/04"

PART N0. 62A245


BERGEN POWER PIPE SUPPORTS, INC.
titr, d
Y
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CLAMP for SIRUTASSEMBTTES - PART NUMBER 6202'25k

'l DIRECTION
* I
----'t'---- -
I
OF
LOADING

t Temperature: 6500F

No"'
For. the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition,

Operating Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
4 25,000 25,000 33,250 37,500 46,975 33,250
5 25,000 25,000 33,250 37,500 46,975 33,250
6 25,000 25,000 33,250 37,500 46,975 33,250
I 25,000 25,000 33,250 37,500 46,975 33,250
10 25,000 25,000 33.250 37,500 46,975 33,250
12 25,000 25,000 33.250 37,500 46,975 33,250
14 25,000 25,000 33,250 37,500 46,975 33,250
16 25,000 25,000 33,250 37,500 46,975 33,250
18 25,000 25,000 33,250 37,500 46,975 33,250
2g 25,000 25,000 33,250 37,500 46.975 33,250
24 25,000 25,000 33,250 37,500 46,975 33,250
30 25,000 25,000 33,250 37,500 46,975 33,250
36 25,000 25,000 33,250 37.500 46,975 33,250
Rated Loads (lbs) for Classes 1,2,3 &MC
I certify this CDRS oomplies with the
CONTROL REF NO. 6202
requircments of ths applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: S4-564 WP 630
Bergen Power Pipe SuPPods, lnc.
Studs: SA-36
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVISIONS
/o\ Oriqinal lssue 10/27109 /i
tt:,* 4,&.#' A
/^
4\
/n
Stet lra/zz/ol lslGNED

BERGET'J POWER PIPE SUPPORTS, INC, SHEET L OF l- REV. A PART N0, 6202.25
CDRS CATALOG INFORMATION SHEET

PIPE CUMP fOr STRIJIASSEMBT'ES . PART NUMBER 6202-25K

STOCK
PIPE SIZE D E l|:| P D
TiW
4 2114 91t4 1 7116 1 7 1-114x5
5 2114 10 1 7t16 1 7 3t4 1-114 x5
6 21t4 11 I 7t16 1 8 3/8 1-114 x5
8 21t4 12 1 7t16 1 I 5/8 1-114 x5
10 2114 131t2 I 7t16 1 10 3t4 1-114 x5
12 21t4 14112 1 7t16 1 11718 1-114 x5
14 2114 16 1 7116 1 131t8 1-112x5
16 21t4 17 1 7t16 1 14118 1-112x5
18 21t4 18 1 7116 1 151t4 1-112x6
20 2114 19 1 7t16 1 16 3/8 1-112x6
24 2114 22 1 7t16 1 183t4 1-314 x5
30 21t4 25 1 7116 1 22 1^314 x5
36 2114 28 1 7116 I 251t8 1-314 x7
NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only' '

3.) This Ctamp is compatible with B-P Parts 2250,2252, 2420,2440, 2525 and 2530'
place'
4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in

ORDERING INSTRUCTIONS :
Specify: Part Number, CDRS Revision Number, and Pipe Size.

DGMPLE: 6202-25-N04',

inallssue 10127109

PART N0. 6202-25


BERG EN POWER PIPE SUPPORTS, INC, SHEET 1 0F 1
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP for STRUIASSEMBTTES - PART NUMBER 6202-35k

DIRECTION
OF
LOADING

Temperature: 6500F

*ott'
For" the test condition (Hydro)the maximum temperature is 100oF. For higher
Design Spec. No. D96202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operatins Conditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
I 35,000 35,000 46,550 52,500 65,765 46,550
10 35,000 35,000 46,550 52,500 65,765 46,550
12 35,000 35,000 46,550 52,500 65,765 46,550
14 35,000 35,000 46,550 52,500 65,765 46,550
l6 35,000 35,000 46,550 52,500 65,765 46,550
18 35,000 35,000 46,550 52,500 65,765 46,550
20 35,000 35,000 46,550 52,500 65,765 46,550
24 35,000 35,000 46,550 52,500 65,765 46,550
30 35,000 35,000 46,550 52,500 65,765 46,550
36 35,000 35,000 46,550 52,500 65,765 46,550
Rated Loads (lbs) for Classes 1,2,3 &MC

I cortify this CDRS complies with he CONTROL REF NO. 6202


r€quirements of the applcable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power Pipe Suppodg lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-21 21)
REV|SIONS
/dr I Oriqinal lssue 1 0/27109 i
t*>K,&,.fr /.r\ J /r\
i
SFAL lta/Zz,/a? ISIGNED /^
BERGEN POWER PIPE SUPPORTS, INC.
-L
SHEET 1 0F 1 REV.
A PART NO. 6202.35
CDRS CATALOG INFORMATION SHEET

PIPE CLAMP fOT SIRUTASSEMBT'ES . PART NUMBER 6202'35K

STOCK
PIPE SIZE D E G P S
TxW
8 2518 12 117t32 11t4 101t4 1-114 x6
10 2518 13112 117t32 1114 113t4 1-112x5
12 2518 141t2 117132 11t4 12718 1-112x5
14 2518 16 117132 11t4 133t4 1-112xB
16 25t8 17 117132 11t4 14 3t4 1-112x6
18 25t8 18 117132 1 1t4 157t8 1-112x7
20 2518 19 117t32 1 1t4 17 1-112x7
24 2 518 22 117132 1 114 191t2 1-314 x6
30 2 518 25 117t32 1 1t4 22518 1-314 xT
36 25t8 28 117t32 1 114 25 5t8 1-314x8

1.) All dimensions are in inches.


2.) Dimensions are provided for user applbation only'
3.)This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530.
place'
4.) lnstallation: Tension bolts to remove slack, plus ll2lurnof nut, then lock in

ORDERING INSTRUGTIONS :
Specify: Part Number, CDRS Revision Number, and Pipe Size.

DGMPLE: 6202-35-R/0-16"

inallssue 10127109

0F
BERGETV POWER PIPE SUPPORTS, INC. SHEET 1 1
tir r, d
b
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP for STRUIASSEII4BL,ES - PART NUMBER 6202-50k

b
@@

DIRECTION
OF
LOADING

o@ I

1 Temperature: 6500F

Nott'
For the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Gonditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
10 50,000 50,000 66.500 75,000 93,950 66,500
12 50,000 50,000 66,500 75,000 93,950 66.500
14 50,000 50,000 66,500 75,000 93,950 66.500
16 50,000 50,000 66,500 75,000 93,950 66,500
18 50,000 50,000 66,500 75,000 93,950 66,500
20 50,000 50,000 66,500 75,000 93,950 66,500
24 50,000 50,000 66.500 75,000 93,950 66,500
30 50,000 50,000 66,500 75,000 93.950 66,500
36 50,000 50,000 66,500 75,000 93.950 66,500
Rated Loads (lbs) for C/asses 1,2,3 & MC

* Two bolt configuration is for Pipe Size 10 Only.

I certfy this CDRS complies with $e CONTROLREFNO. 6202


requirements of the applicatrle code MATERIALS
The Design Repoil & Design Specification are in
Plate: 5A-36
accodance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: SA-564 TYP 630
Bergen Power Prpe Supporls,lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-2121)
REV|S|ONS
/t Orioinal lssue 10/27109 /t\
e4-htr,d'fr /t\ /t\
/J
$EAL l/dh?/ot lslGNED /z\

BERGE,\J POWER PIPE SUPPORTS, INC. SHEET 1 OF 1 REV. A PARTNO. 6202-50


CDRS CATALOG INFORMATION SHEET

PIPE CUMP fOr SIRUIASSEMBT'ES . PART NUMBER 6202.50K

10'

'il[
b
r-

E
oo
I

t_
I

I
I

S :
.,4-
t919
-,4.

STOCK
PIPE SIZE D E t(t P s
TxW
{0 2114 141t4 13t4 11t2 101t4 1-112x6
12 2114 15114 13t4 11t2 113t4 1-112x7
14 21t4 16314 1314 1112 127t8 1-112 x7
16 2114 17 314 13t4 11t2 13314 1-112x7
18 2114 18 314 1314 1112 143t4 1-314 x7
20 21t4 193t4 1314 1112 15718 1-314x7
24 21t4 22314 13t4 11t2 17 1-3i4 x 8
30 21t4 2s314 13t4 11t2 19112 1-314 x9
36 2114 283t4 1314 11t2 225t8 1-314x10

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) This Clamp is compatible with PSA-35 and B-P Parls 2440,2525 and 2530'
4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place,
* 5.) Two bolt configuration is for Pipe Size 10 Only'

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

DGMPLE: 6202-50-R/0-16"

REVISIONS
inal lssue 10127109

PART N0. 6202.50


BERGEAJ POWER PIPE SUPPORTS, INC,
tit f' d
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PI PE CLAMP for SIRUI A SSE ItBt,ES - PART NU MBER 6202-60k

b
oo
I DIRECTION
OF
LOADING

@@ Temperature: 6500F

no"'
Fo, the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Repoft No. DR-6202
shown for the Operating Condition.

Operatins Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
10 60,000 60,000 79,800 90,000 112.740 79,800
12 60,000 60,000 79,800 90,000 112,740 79,800
14 60,000 60.000 79,800 90,000 112,740 79,800
16 60,000 60,000 79,800 90,000 112,740 79,800
18 60,000 60,000 79,800 90,000 112,740 79,800
20 60,000 60,000 79,800 90,000 112.740 79,800
24 60,000 60,000 79,800 90,000 112,740 79,800
30 60,000 60,000 79,800 90,000 112,740 79,800
36 60,000 60,000 79,800 90,000 112,740 79,800
Rated Loads (lbs) for C/asses 1,2,3 &MC

* Two bolt configuration is for Pipe Size 10 Only.

I certify this CDRS complies with lhe CONTROLREFNO. 6202


rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 3A-564 TYP 630
Bergen Power Pipe Supports, lnc.
Studs: 3A-36
Product Engineering Department
xempt Cotter pins, Washers, Retainers (NF-2121)
REVtStONS
/o\ Oriqinal lssue 10/27109 /i
A*'tu/,(%,fr' ZT /t
SEAL 176/22/a9 ISIGNED /z\ /)
BERGEfV POWERPIPE SUPPORTS, INC. SHEET 1 OF I REV.
A PART N0, 6202,60
litr, nl
CDRS CATALOG INFORMATION SHEET

-
PIPE CLAMP for SIRUIASSEMBTTES - PART NUMBER 6202'60k

10'

1,tr
b
4HFJ'
oo
L _l
I

o@
STOCK
PIPE SIZE D E t P s
TxW
10 21t4 141t8 1314 1112 11 1t2 1-3/4 x 6
12 21t4 15114 13t4 11t2 125t8 1-314 x7
14 2114 16 3t4 13t4 11t2 13112 1-314 x7
16 21t4 17 314 13t4 11t2 14 9/16 1-314 xT
18 21t4 18 3t4 1314 1112 16 1t16 2x7
20 21t4 19 3t4 13t4 11t2 17 1t8 2x7
24 21t4 223t4 13t4 1112 19 7116 2xB
30 21t4 2s3t4 13t4 11t2 22112 2x9
36 21t4 283t4 13t4 11t2 25 5t8 2x10

NOTES:
1.) All dimensions are in inches.
2,) Dimensions are provided for user application only.
3,)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525 and2530.
4.) lnstallation: Tension bolts to remove slack, plus ll2turn of nut, then lock in place.
* 5.)Two bolt configuration is for Pipe Size 10 Only.

ORDERING INSTRUCTIONS :

Specify: Part Number, CDRS Revision Number, and Pipe Size.

EXAMPLE: 6202-60-R/0-16"

REVISIONS
/o\ Oriqinal lssue 1 0/27109 /s\
/4'
/2' /i
BERG EN POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV.
A PART N0. 6202.60
titL *
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP Ior STRUTASSE,I'BIIES . PART NUMBER 6202.80K

b
e@
DIRECTION
OF
LOADING

Temperature: 6500F

No*t'
Fo, the test condition (Hydro)the maximum temperature is 1000F, For higher
Design Spec. No. D$6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition,

Operatino Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
10 80,000 80,000 106,400 120,000 150,320 106,400
12 80,000 80,000 106,400 120,000 150,320 106,400
14 90,000 90,000 106,400 120,000 150,320 106.400
16 80,000 80,000 106,400 120,000 150,320 106,400
18 80,000 80,000 106,400 120,000 150,320 106,400
20 80,000 80,000 106,400 120,000 150,320 106,400
24 80.000 80,000 106,400 120,000 150,320 106,400
30 80,000 80,000 106,400 120,000 150,320 106,400
36 80,000 80,000 106,400 120,000 150,320 106,400
Rated Loads (lbs) for C/asses 1,2,3 & MC

I certify this CDRS complies with he CONTROLREFNO. 6202


requiremenG of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 3A-564 TYP 630
Bergen Power Pipe Supporfs, lnc.
Studs: SA-36
Product Engineering Department
Exempt Cotter pins, Washers, Retainers (NF-21 21)
REVISIONS
/NlOriqinal lssue 10/27109 /3\
At>R,&.*, /t /t
$EAL 147a774t ISIGNED /i /s\

BERGEN POWER PIPE SUPPORTS, INC, SHEET 1 OF 1 REV. A PART N0. 6202.80
CDRS CATALOG INFORMATION SHEET

PIPE CUMP fOr SIRUIASSEMBI'ES . PART NUMBER 6202.80K

b
oo
I

oo
STOCK
PIPE SIZE D E G P s
TxW
10 3 15 17t8 13t4 11st8, 1-314x9
12 3 16 1718 13t4 12 3t4 1-3/4 x 9
14 3 17 17t8 13t4 1311t16 1-314 x 10
16 3 18 17t8 13t4 14314 1-314 x 10
18 3 19 1718 13t4 157t8 1-314 x 11
20 3 20 1718 13t4 17 1-314 x 11
24 3 23 17t8 13t4 19 1 1/16 2x11
30 3 26 17t8 13t4 2213116 2x11
36 3 291t4 1718 1314 26 5/16 2-114 x 11

NOTES:
1.)Alldimensions are in inches.
2.) Dimensions are provided for user application only.
3.) This Clamp is compatible with B-P Parts 2250,2252,2525 and 2530.
4.) lnstallation: Tension bolts to remove slack, plus ll2lurn of nut, then lock in place.

ORDERING INSTRUCTIONS :
Specify: Part Number, CDRS Revision Number, and Pipe Size'

DGMPLE: 6202-80-R/0-16"

REVISIONS
ffizzlog /i
/t /A
/z\ /i
BERGEA' POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 REV. A PARr N0. 6202.80
til J, *
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE CUMP for STRUI ASSEMBTTES - PART NUMBER 6202.120k

b
9-9
DIRECTION
OF
LOADING


+
oo Temperature: 6500F

Nott'
Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
11 120,000 120,000 159,600 180.000 225,480 159,600
16 120,000 120,000 159,600 180,000 225,480 159,600
18 120,000 120.000 159,600 180,000 225,480 159,600
20 120,000 120.000 159,600 180,000 225,480 159,600
24 120,000 120,000 159.600 180,000 225,480 159,600
30 120,000 120,000 159,600 180,000 225,480 159,600
36 120,000 120,000 159,600 180.000 225,480 159,600
Rated Loads (lbs) for C/asses 1,2,3 & MC

I certify tris CDRS complies with lhe CONTROL REF NO. 6202
rcquirements of lhe applicable ode MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: SA-564 TYP 630
Bergen Power Pipe Suppods, lnc.
Studs: SA-36
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REVtStONS
/o\ Oriqinal lssue 10/27109 /J
eq:* ft,d^'#" /t\
SEtt lp/p>/ogIS]GNED /^ /]
BERGEN POWERPIPE SUPPORTS, INC. SHEET 1 OF 1 REV.
A PART N0. 6202.120
CDRS CATALOG INFORMATION SHEET

PIPE CLAMP for SIRUIASSEI4BLIES ' PART NUMBER 6202'120k


10"

b
oo

-.:
oo
STOCK
PIPE SIZE D E G P s
TxW
14 3 1/8 19114 2 3132 2112 137t8 1-3/4 x 10

16 3 1/8 20114 2 3132 21t2 15 1-314 x10


18 3 1/8 21114 2 3t32 2112 161t8 1-3/4 x'10

20 3 1/8 221t4 2 3132 21t2 17 1t8 1'3/4 x 10


24 3118 24 3t4 2 3t32 2112 19112 1-314x14
30 31t8 28114 2 3132 2112 22518 1-314x14
36 31t8 31112 2 3t32 21t2 26 1-314 x15

NOTES:
1.)Alldimensions are in inches'
2')DimensionSareprovidedforuserapplicationonly.
3')ThisClampiscompatiblewithPsA-100andB.PPart'2440.
place.
4.) lnstallation: Tension bolts to remove slack, plus 1/2 tum of nut, then lock in

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

DGMPLE: 6202-120-R/0-16"

al lssue 10127109

PART N0. 6202-120


BERGEN POWER PIPE SUPPORTS, INC' SHEET 1 oF 1
titr, *
b
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CLAMP for SIRUI ASSEIfBITES - PART NUMBER 6202'130k

b
o@
DIRECTION
OF
LOADING

oo
.E-

Temperature: 6500F
I
Nott'
Fol. the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D$6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Gondition


Size Design Condition (see Note)
Level A Level B Level C Level D
14 130,000 130,000 172,900 195,000 244,270 172,900
16 130,000 130,000 172,900 195.000 244,270 172,900
1E 130,000 130,000 172,900 195,000 244,270 172,900
20 130,000 130,000 172,900 195,000 244,219 172,900
24 130,000 130,000 172,900 195,000 244,270 172,900
30 130,000 130,000 172,900 195,000 244,270 172,900
36 130,000 130,000 172,900 195,000 244,274 172,900
Rated Loads (lbs) tor C/asses 1,2,3 & MC

I certify this CDRS complies with he CONTROL REF NO. 6202


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 3A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 54-564 TYP 630
Bergen Power Pipe SupPorts, lnc.
Studs: 5A-36
Product Engineering DePailment
ile rn pt
-Cotter
p in s, Wa she rs, Reta i ne rs ( N F-2 1 2 !L
REVISIONS
/o\ Oriqinal lssue 1 0/27109 /J
{4":,*/'&,A /\ /t
/i
SEAL Va/zt/ot lslGNED /t\

BERGETV POWER PIPE SUPPORTS, INC, SHEET 1 0F I REV,


A PART NO. 6202.130
CDRS CATALOG INFORMATION SHEET

PIPE CLAtrIIP fOr STRUTASSEMBTIES


. PART NUMBER 6202'130K

\^\4

oo
%'
Tvp,

-:
oo
STOCK
PIPE SIZE D E lo P s
TxW
14 3112 19114 2 3132 2112 13718 1-3/4 x 10

16 3112 20114 2 3132 21t2 15 1-3/4 x 10

18 31t2 21114 2 3132 21t2 16 1/8 1-3/4 x 10

20 3112 22114 2 3132 21t2 17 118 1-il4 x10


24 3112 24 314 2 3132 2112 19112 1-314x14

30 31t2 28114 2 3t32 2112 22518 1-314 x14


36 3112 31112 2 3132 2112 26 1-3/4 x 15

NOTES:
1.) All dimensions are in inches'
2.) Dimensions are provided for usei application only'
and2530'
3,)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525
plus l12lurn of nut, then lock in place'
4.) lnstallation: Tension bolts to remove slack,

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

EXAMPLE: 62A2'130-R/0-16-

nallssue 10127109

0F PART N0. 6202'130


AERGflV POWER PIPE SUPPORIS' INC.
SHEET 1 1
tit f' r*
H
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE CLAIIIP for SIRUIASSEMBLTES - PART NUMBER 6202'200k

b
q9
-T DIRECTION
OF
LOADING

:
@o Temperature: 6500F

Nott'
Fo1. the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. t{o. DS-6202
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6202
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition Level D (see Note)
Level A Level B Level C
16 200,000 200,000 266,000 300,000 375,800 266,000
18 200,000 200,000 266,000 300,000 375,800 266,000

20 200,000 200,000 266,000 300,000 375,800 266,000


24 200,000 200,000 266,000 300,000 375,800 266,000

30 200,000 200,000 266,000 300,000 375,800 266,000

36 200,000 200,000 266,000 300,000 375,800 266,000


Ratedloads (lbs) for C/asses 1,2,3 & MC

he CONTROL REF NO. 6202


I certify this CDRS complies with
requirements of lhe applicable code MATERIALS The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: 5A-564 TYP 630
Bergen Power PtPe SuPPorts, Inc.
Studs: SA-36
Product Engineering DePartment
Exempt Totter pins, Washers, Retaine1g l!F-!l!])
REVIS|ONS
/il Orioinal lssue 10/27109 /J
Le*hR,&,ffi /1\ /\
Ster lto/tz/o?lslcNED /z\ /i
BERGEN POWER PIPE SUPPORTS, NC. SHEET 1 0F 1 REV. A PART NO. 6202-200
CDRS CATALOG INFORMATION SHEET

PIPE CLAMP for SIRUI ASSEMBTTES 'PART NUMBER 6202-204R

10"

AL
b
4HF]'
/8
7/n
oo
Tttp.

oo
#

_]-l l-_f

STOCK
PIPE SIZE D E G P s
TxW
16 6 21 31t2 4 16114 1-314x12
18 6 22 3112 4 17 112 1-314x12
20 6 23 3112 4 18 112 1-314x12
24 6 26 3112 4 207t8 1-314 x14
30 6 29 3112 4 24118 1-314 x14
36 6 32114 3112 4 27 112 1-3/4 x 15

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only'
3.)This Clamp is compatible with B-P Parts 2250,2252,2421,2440,2525 and2530.
lock in place.
4.) lnstallation: Tension bolts to remove slack, plus 1/2 turn of nut, then

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

DGMPLE: 6202-200-R/0-16'

al lssue 10127l\g

PART N0. 6202-200


BERGEN POWER PIPE SUPPORTS, INC,
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
PART NAME

DIRECTION
OF
LOADING

Temperature:-1Q50'lf

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100T. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

)ESIGN SPEC NO.: DS-6242 R0


e1 K :SIGN REPORT NO.: DR-6242 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MG
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D {see Note)
1/2 125 125 166 188 250 166
314 125 125 166 188 250 166
1 125 125 166 188 250 166
1 1t4 300 300 399 450 600 399
1 112 300 300 399 450 600 399
2 300 300 399 450 600 399
2112 450 450 599 675 900 599
3 450 450 599 675 900 599
4 450 450 599 675 900 599
6 500 500 665 750 1 000 665

I certify this CDRS complies with the


requirements of the applicable Code.

Materials: The Design Report & Design Specification


a Plate: 5A-36 are in accordance with ASME BPVC Section lll,
a
(D Subsection NF, 2007 Edition and are on file at
Irl

ffi
f,
a
a CLOUTIER Bergen Power Pipe Supports,lnc.
J
Product Englneerlng Department
z
o
E NO. 6242
o CONTROL REF
PART NO.

A
Sheet
BERGEN.POWER PIPE SUPPORTS, INC. 1of1 6242
REV Certification
LATERAL RESTRAINT PIPE STRAP

T/16" CLR.

f "o" w ----r

PIPE STZ;E A B T w
r/2" 1r' 3tt r/4" 2"
3/4" 1 3/16" 3" r/4" 2"
{ sv 1" 17/16" 3 r/4" r/4" 2"
IEV
1 r/4" 1 r3/1 6" 3 r/?" 3/9" 3"
1 r/2" ?,, 4" 3/9" 3"
2" 2 r/2" 4 r/2" 3/8" 3r'
2 r/2" 3t' 5" t /2" 3"
3t' 3 5/9" 5 r/2" I /?" 4"
4" 4 5/8" 6 r/2" r/2" 4"
6" 6 3/4" 8 r/2" r /2" 6"
NOTES:
1. All dim ensions are in inches.
N
2. Dimensions are provided for user application only.
o 3. A full penetration weld may be used in lieu of tillet weld both sides.
o
ct
tIJ
f Orderino lnstructions:
a
a Specity part No., CDRS revision No., and size designation.
J
z
CI Example:
E
o Part 6242 - R/0 - 4"
G \o
tEV

TiH BERGEN-POWER PIPE SUPPORTS PART 6242


HJ
fl CDRS CATALOG INFORMATION SHEET DATE 91112007
CERTIFIED DESIGN REPORT SUMMARY
for
TT7l.
Hd NUCLEAR POWER PLANT STANDARD SUPPORTS
H PART NAME

DIRECTION
OF
LOADING

Temperature:650 'F
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

)ESIGN SPEC NO.: DS-6243


:SIGN REPORT NO.: DR-6243
F iE'v Rated Loads (lbs) for classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
1/2 600 600 798 900 1 200 798
314 600 600 798 900 1 200 798
1 600 600 798 900 1 200 798
1 114 1 500 1 500 1 995 2250 3000 995
1

1 1t2 1 500 1 500 1 995 2250 3000 995


1

2 1 500 1 500 1 995 2250 3000 1 995

2112 2500 2500 3325 3750 5000 3325


3 2800 2800 3724 4200 5600 3724
4 2800 2800 3724 4200 5600 3724
6 3000 3000 3990 4500 6000 3990

I certify this CDRS *itn tn" I


requirements of the "otOfi"t
applicable Code. I

Materials: The Design Report & Design Specification


N
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
a Subsection NF, 2007 Edition and are on file at
O)
IU
EUGENE
:f R.
a
U) CLOUTIER Bergen Power Pipe Supports, lnc.
J
Product Engi neerlng DePartment
z
(,
tr CONTROLREFNO. 6243
o
PAt{ | N(,.
qKK Sheet REV.
BERGEN.POWER PIPE SUPPONTS, INC. 1of /a\. 6243
REV Certification 1
VERTICAL RESTRAINT PIPE STRAP

w--l
PIPE STZE A B T w
r/2" 3tt 29/32" r/4" 2"
3/4" 3 r/2" 1 r/8" r/4" 2t'
1" 4" 1 3/8" r/4" ?,,

{ \ s 1 r/4" 4 r/2" 1 3/4" 3/8" 3"


lEV 1 r/2" 5" 2" 3/8" 3"
2" 5 r/?" 2 7 /16" 3/8" 3"
2 r/2" 6" 2 r5/t6" r/2" 3"
3" 6 r/2" 3 9/16" r/2" 4"
4" 7 r/2" 4 9/16" r/2" 4"
6" 9 3/4" 5 r5/t6" r/2" 6t'

NOTES:
1. All dim ensions are in inches.
F-
2. Dimensions are provided for user application only.
O 3. A full penetration weld may be used in lieu of fillet weld both sides.
o
O)
uJ
l Orderinq lnstructions :
a
2 Specify part No., CDRS revision No., and size designation.
J
z
g Example:
E
o Part 6243 - R/0 - 4"
G (o
REV

m
fl
BERGEN.POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE
6243
9t112007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF. AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

l {---}

DIRECTION
OF
LOADING

I remperature: 650 " F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6202 R3


DESIGN REPORT NO.: DR-6202 R0
7 Rated Loads (lbs) for Glasses 1,2,3 & MC
6i -$

REV Design OPERATING CONDITIONS Test Condition


PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
11t2 350 350 466 525 650 466
2 350 3s0 466 525 650 466
21t2 350 350 466 525 650 466
3 350 350 456 525 650 466
4 350 350 466 525 650 466
5 350 350 466 525 650 466
6 350 350 466 52s 650 466
I 350 350 466 525 650 466
10 350 350 rt66 525 650 466
12 350 350 466 525 650 466
14 350 350 466 525 650 466
16 350 350 466 525 650 466

NOTE: For use only with Mechanical Struts manufactured by Pacific Scientific Company per
bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted
at 90oto each other and 45'from the vertical centerline of the clamp. Supplied by others.

lc"ry
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
t\
o
o
Plate: SA-36 are in accordance with ASME BPVC Section lll,
o, Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
)
UJ

U)
Pin: SA-654 TYPE 630
L
J
Nuts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
z Studs: 54-36 Product Engineering Department
o
E
o Cotter pins, Washers, Retainers Exempt (NF-l110) CONTROLREFNO. 6252
Sheet REV.
PAIII NU.
BERGEN.POWER PIPE SUPPORTS, INC. l
REV Certification of 1 /a\. 6252-.95
OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

D .no.

d
O -::T::-

+-
I

PIPE STOCK
D E G P s
SIZE SIZE TXW
1 1t2 7t16 4 3t4 13t32 3t8 213t16 1t2X 2
2 7t16 5 13t32 3/8 3 1/8 1t2X2
21t2 7116 5 314 13t32 3t8 31t2 1t2 X2 1t2
3 7t16 6 13t32 3t8 3 7t8 1t2X2 1t2
4 7t16 7 13t32 3t8 4 3t8 1t2 X2 112
5 7t16 7 1t2 13t32 3/8 5 1t2X2 1t2
6 7t16 8 13t32 3/8 5112 1t2X3
I 7t16 9112 13t32 3t8 6 13/16 1t2 X3
10 7t16 11 13t32 3t8 8 3/16 5/8 X3
12 7t16 12 13t32 3t8 9112 5/8 X3
14 7t16 13 13t32 3/8 10 1/8 s/8 x3
16 7t16 14 13t32 3/8 11 1t4 5/8 X3
F-
o NOTES: 1 . All dimensions are in inches and are provided for user information only.
o
F

o, 2. This clamp is compatible with B-PPS Parts 2440 and PSA- 114.
uJ
f 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
U)
L then lock in place
J
z
g ORDERING INSTRUCTIONS:
CE
o Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size.
EXAMPLE: Part 6252-.35--Rl0-2"

BERGEN.POWER PIPE SUPPONTS INC. PART 6252-.35


CDRS CATALOG INFORMATION SHEET DATE 9/01 t2007
a

nls
Hd
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF - AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

90"

--r {*

DIRECTION
OF
LOADING

I femperature: 650 'F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6202 R3


DESIGN REPORT NO.: DR-6202 R0
a Rated Loads (lbs) tor classes 1,2,3 & MG
RRV Design OPERATING CONDMONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
11t2 650 650 865 975 1220 865
2 650 650 865 975 1220 865
21t2 650 650 865 975 1220 865
3 650 650 865 975 1220 865
4 650 650 865 975 1220 865
5 650 650 865 975 1220 865
6 650 650 865 975 1220 865
8 650 650 865 975 1220 865
10 650 650 865 975 1220 865
12 650 650 865 975 1220 865
14 650 650 865 975 1220 865
16 650 650 865 975 1220 865

NOTE: For use only with Mechanical Struts manufactured by Pacific Scientific Company per
bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted
at 90oto each other and 45ofrom the vertical centerline of the clamp. Supplied by others.

-".ry
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
r\
O
Plate: sA-36 are in accordance with ASME BPVC Section lll,
<)
o) Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
LU
l
a
Pin: 5A-654 TYPE 630
a
J
Nuts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
z Studs: SA-36 Product Engineering Department
CI
CE
o Ootter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252
(K 7
e Shest REV.
PAH| N(,.
BERGEN.POWEN PIPE SUPPORTS, INC. l of /a\. 6252-.65
REV Certification 1
OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

10"
--P D nno.
_t

d
O +
I

6 6 PIPE STOCK
lEV D E G P S
SIZE SIZE TXW
1 112 7t16 4 314 13t32 3t8 213t16 1t2X2
2 7t16 5 13t32 3/8 3 1/8 1t2X 2
2 1t2 7t16 5 314 13t32 3t8 31t2 1t2X2 1t2
3 7t16 6 13t32 3t8 3 7t8 1t2 X2 112
4 7t16 7 13t32 3t8 4 3t8 1t2X2 112
5 7t16 7 1t2 13t32 3/8 5 1t2X2 1t2
6 7t16 8 13t32 3/8 5112 1t2X3
8 7t16 91t2 13t32 3t8 6 13/16 1t2 X3
10 7116 11 13t32 3t8 8 3/16 5/8 X3
12 7t16 12 13t32 3/8 9112 s/8 x3
14 7t16 13 13t32 3/8 10 1/8 5/8 X3
16 7t16 14 13t32 3t8 11 1t4 5/8 X3
F-
c)
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o
o, 2. This clamp is compatible with B-PPS Parts 2440 and PSA- 112.
3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
TIJ
l
ct)
a then lock in place
J
z
0 ORDERING INSTRUCTIONS:
E
o Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size.
G G EXAMPLE: Part 6252-.65--Rl0-2"
REV

rns BERGEN.POWER PIPE SUPPORTS INC. PART 6252-.65


Hf
fl CDRS CATALOG INFORMATION SHEET DATE 9/01t2007
a

ms
CERTIFIED DESIGN REPORT SUMMARY
for
Hd NUCLEAR POWER PLANT STANDARD SUPPORTS
H OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

90"

\ <+

DIRECTION
OF
LOADING

I remperature:-U
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6252


DESIGN REPORT NO.:
Rated Loads (lDs) ror glasses 1r2r3 & M(;
SI
F IRV Design OPERATING CONDITIONS Test Condition
PIPE SIZE (see Note)
Condition Level A Level B Level C Level D
1 1t2 700 700 931 1 050 1300 931
2 700 700 931 1 050 1300 931
2 112 700 700 931 1 050 1300 931
3 700 700 931 1 050 1300 931
4 700 700 931 1 050 1 300 931
5 700 700 931 1 050 1 300 931
6 700 700 931 1 050 1 300 931
I 700 700 931 1 050 1300 931
10 700 700 931 1 050 1300 931
12 700 700 931 1 050 1300 931
14 700 700 931 1 050 1300 931
16 700 700 931 1 050 1 300 931

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45'from the vertical centerline of the clamp. Supplied by others.

requirements of the applicable Code.

Materials: The Design Report & Design Specification


N
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
o, Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
t.U
f
a
Pin: 5A-654 TYPE 630
a
) Nuts: S4-563 GR A Bergen Power Pipe Supports, lnc.
z Studs: 5A-36 Product Engineering DePartment
g
tr CONTROLREFNO. 6252
o lotter pins, Washers, Retainers Exempt (NF-1 110)
PART NO.
Sheet REV.

REV Certification
BERGEN.POWER PIPE SUPPORTS, INC. 1of1 ,A 6252-.7
OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

D .no.

7l\ d I

\to I 6 PIPE STOCK


lEV D E G P S
SIZE SIZE TXW
1 112 7 t16 4 314 17132 3/8 213116 1l2X 2
2 7 t16 5 17132 3/8 3 1/8 1lzx 2
2 112 7 t16 5 314 17132 3/8 3 112 112X2 112
3 7 t16 6 17132 318 3 718 112X2 112
4 7116 7 17132 3/8 4 3t8 1t2X2 112
5 7116 7 112 17132 318 5 112X2 112
6 7116 8 17132 318 5 112 1t2X3
I 7 t16 I 112 17132 318 6 13/1 6 1t2X3
10 7 t16 11 17132 318 8 3116 5/8 X3
12 7 t16 12 17132 318 I 112 5/8 X3
14 7 t16 13 17132 318 101/8 5/8 X3
16 7 t16 14 17132 318 11 114 5/8 X3
r-
o NOTES: 1 . All dimensions are in inches and are provided for user information only.
o
F

CD 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420 and 2440.


3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
LU
f
ct)
a then lock in place
J
z
0 ORDERING INSTRUCTIONS :
E
o Specify Part No. ,Size Designation, CDRS Rev. No. and Pipe size.
<" G EXAMPLE: Part 6252-.7 -Rl0-2"
lEV

fi75 BERGEN-POWER PIPE SUPPORTS INC. PART 6252-.7


HN
E CDRS CATALOG INFORMATION SHEET DATE 9/01t2007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF - AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

.e

DIRECTION
OF
LOADING

I femperature: 650 " F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6202 R3


DESIGN REPORT NO.: DR-6202 R0
HateilL6eds (lbs) tor Classes 1,2,3 & MC
RRV Design OPERATING CONDMONS Test Gondition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
2 1500 1500 1995 2250 2820 1995
21t2 1500 1500 1995 2250 2820 1995
3 1500 1500 1995 2250 2820 1995
4 1500 1500 1995 2250 2820 1995
5 1500 1500 1995 2250 2820 1995
6 1500 1500 1995 2250 2820 1995
8 1500 1500 1995 2250 2820 1995
10 1500 1500 1995 2250 2820 1995
12 1500 1500 1995 2250 2820 1995
14 1500 1500 1995 2250 2820 1995
16 1500 1500 1995 2250 2820 1995
18 1500 1500 1995 2250 2820 1995
20 1500 1500 1995 2250 2821 1995

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.

I certify this CDRS complies with the


requirements of the applicable Code.

Materials: The Design Report & Design Specification


F-
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
o, EUGENE Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
LU
:)
a R. Pin: 5A-654 TYPE 630
@ CLOUTIER Nuts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
J
Studs: 5A-36 Product Engineering DePartment
g
=
(r
o Cotter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252
PART NO.
Sheot REV.
BERGEN.POWER PIPE SUPPORTS, INC. ,/N
REV Certification lof 1 6252-1.5
OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

10"
D .no.

d
5
0 +-
I

PIPE STOCK
D E G* P S
SIZE SIZE TXW
C \(Y)

REV 2 518 5 21132 112 3 114 5/8X3


2112 5/8 5 314 21132 112 3 5/8 5/8X3
3 5/8 6 21132 112 4 5/8X3
4 518 7 21132 112 415116 314X3
5 5/8 7 112 21132 112 5 9/1 6 314X3
6 5/8 8 21132 112 6 112 314X3
8 5/8 I 112 21132 112 7 13116 3t4X3
10 5/8 11 21132 112 I 114 314X4
12 5/8 12 21132 112 10 3/8 314X4
14 5/8 13 21132 112 11 314X4
16 5/8 14 21132 112 12 314X4
18 518 15 21132 112 13 314X5
20 5/8 16 21132 112 14 314X5

N
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,2525
o
o, 2530 and PSA-1 per PSA Bulletin PSA-4.
3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
uJ
l
a
U) then lock in place
4. * G=1/2" when used with PSA-1. ( Use alternate washers supplied.)
J
z
o ORDERING INSTRUCTIONS:
(E
o Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size. and "G" Required.
G G EXAMPLE: Part 6252-1.5-Rl0-2" G= 21132"
lEV
BERGEN-POWER PIPE SUPPORTS INC. PART 6252-1 .5
TFTS
U
H*
CDRS CATALOG INFORMATION SHEET DATE 9/01 t2007
ffi
ru
CERTIFIED DESIGN REPORT SUMMARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

f-----
90"

_\ {*

DIRECTION
I OF
Note: The temperature shown above is for Design and Operating Conditions. For the Test Condi LOADING
the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
3 4000 4000 5320 6000 5600 5320
tEr
F t\ I 4 4000 4000 5320 6000 5600 5320
5 4000 4000 5320 6000 5600 5320
6 4000 4000 5320 6000 5600 5320
8 4000 4000 5320 6000 5600 5320
10 4000 4000 5320 6000 5600 5320
12 4000 4000 5320 6000 5600 5320
14 4000 4000 5320 6000 5600 5320
16 4000 4000 5320 6000 5600 5320
18 4000 4000 5320 6000 5600 5320
20 4000 4000 5320 6000 5600 5320
22 4000 4000 5320 6000 5600 5320
24 4000 4000 5320 6000 5600 5320
26 4000 4000 5320 6000 5600 5320
28 4000 4000 5320 6000 5600 5320
30 4000 4000 5320 6000 5600 5320
32 4000 4000 5320 6000 5600 5320
34 4000 4000 5320 6000 5600 5320
36 4000 4000 5320 6000 5600 5320

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.
cenry rnrs uu.D
r
"oroffiTl
equirements of the applicable Code. I
Materials: The Design Report & Design Specification
N
o
o
Plate: 5A-36 are in accordance with ASME B PVC Section lll,
O) Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
tu
l
a
Pin: 5A-654 TYPE 630
a Nuts: 54-563 GR A Bergen Power Pipe Supports, lnc.
J
z Studs: SA-36 Product Engineering Department
(9
tE
o ]otter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252
PART NO.
Sheet REV.
BERGEN.POWER PIPE SUPPORTS, INC. 1of 1 ,4. 6252-4
REV Certification
a

OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

10"
.P
I

-T

t-l
16" THRU 36"
ONLY

PIPE STOCK
D E G P S
SIZE SIZE TXW
3 7t8 7 3t4 21t32 1t2 4 3t4 1X6
4 7t8 8114 21t32 1t2 6 1t4 1114X5
5 7t8 8 314 21t32 1t2 6 7t8 11t4X5
6 7t8 I 1t2 21t32 1t2 7 5t8 11t4)(5
I 7t8 10 112 21132 1t2 I 114 11t4)(5
C \ct) 10 7t8, 12 21t32 1t2 10 1/2 1114)(6
REV 12 7t8 13 21t32 1t2 115/8 11t4X6
14 7t8 14 21t32 1t2 121t4 1114)(6
16 7t8 15 21t32 1t2 1 1 13/16 11t4X7
18 7ta 16 21t32 1t2 131/8 11t4X7
20 7t8 17 21132 1t2 14 3t8 11t4X7
22 7t8 18 21t32 1t2 15 3/8 11t4X7
24 7t8 19 21t32 1t2 16 15/16 11t2X7
26 7t8 20 21132 1t2 18 114 11t2)(7
28 7t8 22 21t32 1t2 19 114 1112)(7
30 7t8 23 21t32 1t2 20 3t8 11t2X7
32 7t8 24 21t32 1t2 21 3t8 11t2X7
34 7t8 25 21t32 1t2 22 3t8 11t2)(7
36 7t8 26 21t32 1t2 23 3t8 11t2X8
NOTES: 1 . All dimensions are in inches and are provided for user information only.
2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2525 and 2530.
t- 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut.
o then lock in place
o
F

o, 4.4 Bolt configuration for pipe sizes 16" through 36" only.
uJ
f
U)
U) ORDERING INSTRUCTIONS:
z Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size.
o
E EXAMPLE: Part 6252-4-Rl0-4"
o
G s G
IEV

ffi
fl
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART
DATE 9t1t2007
6252.4
a

CERTIFIED DESIGN REPORT


for
NUCLEAR POWER PLANT STANDARD SUPPORTS

Note:
lor
Condi
The temperature shown above is for Design and Operating Conditions. For the Test
+ DIRECTION

the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
LOADING

up to the temperature shown for the Operating Condition. Temperature: 650 o F

DESIGN SPEC NO.: DS-6202 R3


DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level G Level D (see Note)
3 6000 6000 7980 9000 1 1208 7980
4 6000 6000 7980 9000 11208 7980
5 6000 6000 7980 9000 11208 7980
6 6000 6000 7980 9000 1 1208 7980
I 6000 6000 7980 9000 11208 7980
10 6000 6000 7980 9000 1 1208 7980
12 6000 6000 7980 9000 11208 7980
14 6000 6000 7980 9000 11208 7980
16 6000 6000 7980 9000 1 1208 7980
18 6000 6000 7980 9000 11208 7980
20 6000 6000 7980 9000 11208 7980
22 6000 6000 7980 9000 11208 7980
24 6000 6000 7980 9000 11208 7980
26 6000 6000 7980 9000 11208 7980
28 6000 6000 7980 9000 1 1208 7980
30 6000 6000 7980 9000 1 1208 7980
32 6000 6000 7980 9000 11208 7980
34 6000 6000 7980 9000 1 1208 7980
36 6000 6000 7980 9000 1 1208 7980
NOTE: For use only with Mechanical Struts manufactured by Pacific Scientific Company per
bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted
at 90oto each other and 45ofrom the vertical centerline of the clamp. Supplied by others.
I certify this CDRS complies with the

The Design Report & Design Specification


N
o are in accordance with ASME BPVC Section lll,
o
O) Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
tIJ
Pin:

ffi
l 5A-654 TYPE 630
U)
U)
J
CLOUTIER Nuts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
Product Engineering Department
z
(t
(E
o Washers, Retainers Exempt (NF-111

BERGEN.POWER PIPE SUPPORTS, INC.


OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C.
l-e l* wt
10" l

;P D.^0.
t

t-l
16" THRU 36"
ONLY

PIPE STOCK
D E G P S
SIZE SIZE TXW
3 1 7 3t4 13/16 3t4 4 314 1X6
4 1 f31t4 13/16 3t4 61t4 11t4X5
5 1 8 3t4 13/16 314 6 7t8 11t4X5
6 1 91t2 13/16 314 7 5t8 1114)(5
8 1 10 1t2 13t16 314 9114 11t4)(5
\to 6 10 1 12 13/16 3t4 10 1t2 11t4X6
lEV 12 1 13 13/16 314 115/8 11t4)(6
14 1 14 13/16 314 12 114 11t4X6
16 1 15 13t16 314 11 13/16 11t4X7
18 1 16 13/16 314 13 1t8 1 1t4 X7
20 1 17 13/16 314 14 3t8 1114)(7
22 1 18 13/16 314 15 3/8 1 114 X7
24 1 19 13/16 3t4 16 15/16 1 1t2X7
26 1 20 13/16 3t4 18 114 11t2X7
28 1 22 13/16 314 19 1t4 1 1t2X7
30 1 23 13/16 314 20 3t8 1 1t2X7
32 1 24 13/16 314 21 3t8 1 1t2X7
34 1 25 13t16 314 22 3t8 1 1t2X7
36 1 26 13/16 3t4 23 3t8 11t2X8
NOTES: 1 . All dimensions are in inches and are provided for user information only.
F*
2. This clamp is compatible with PSA-3.
o 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut.
o
F

ct) then lock in place.


uJ
f 4.4 Bolt configuration for pipe sizes 16" through 36" only.
U)
U'
J
z ORDERING INSTRUCTIONS:
0 Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size.
CT
o
G G EXAMPLE: Part 6252-6-R l0-4"
IEV

ffi
fl
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART
DATE
6252.6
9t1t2007
ms
CERTIFIED DESIGN REPORT SUMMARY
for
Nd NUCLEAR POWER PLANT STANDARD SUPPORTS
H OFF - AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

go"

t {--}

rl DIRECTION
OF
Note: The temperature shown is for Design and Operating Conditions. For the Test Condi LOADING
"oorl" For higher temperatures in the Test Condition use Level B loads
is 100'F.
the maximum temperature
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDMONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
G 4 7000 7000 9310 10500 14000 9310
RRV 5 7000 7000 9310 10500 14000 9310
6 7000 7000 9310 10500 14000 9310
8 7000 7000 9310 10500 14000 9310
10 7000 7000 9310 10500 14000 9310
12 7000 7000 9310 10500 14000 9310
14 7000 7000 9310 10500 14000 9310
16 7000 7000 9310 10500 14000 9310
18 7000 7000 9310 10500 14000 9310
20 7000 7000 9310 10500 14000 9310
22 7000 7000 9310 10500 14000 9310
24 7000 7000 9310 10500 14000 9310
26 7000 7000 9310 10500 14000 9310
28 7000 7000 9310 10500 14000 9310
30 7000 7000 9310 10500 14000 9310
32 7000 7000 9310 10500 14000 9310
34 7000 7000 9310 10500 14000 9310
36 7000 7000 9310 10500 14000 9310

NOTE: This product must be used with shear lugs,welded to the pipe, mounted at 90'to each
other and 45'from the vertical centerline of the clamp. Supplied by others.

*"*ry
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
I-
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
o, Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
r.rJ
f
a
Pin: SA-654 TYPE 630
a Nuts: SA-194 GR 2H Bergen Power Pipe Supports, lnc.
J
z Studs: SA-193 GR 87 Product Engineering DePartment

0
E CONTROLREFNO. 6252
o Ootter pins, Washers, Retainers Exempt (NF-1 110)
PART NO.
Sheet
EKK BERGEN.POWEB PIPE SUPPORTS, INC.
REV.

REV Certification 1of 1 /a\. 6252-7


OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

10"
tIP
-f

t-l

PIPE STOCK
D E G P s srzE Txw
SIZE
4 1 1t4 8114 29t32 314 5 314 11t2X7
5 1 1t4 8 314 29t32 3t4 61t2 1 1t2 X7
6 1 114 I 112 29t32 314 7 1t8 1112X7
I 1 114 10 1t2 29t32 314 8 3/8 11t2X7
10 1 114 12 29t32 314 I314 11t2X8
\lJ) 6 12 1 114 13 29t32 314 1 1 1116 11t2X8
lEV 14 1 1t4 14 29t32 314 12 3t8 13t4X7
16 1 114 15 29t32 3t4 13 3/8 13t4X7
18 1 1t4 16 29t32 314 14 1t2 13t4X7
20 1 114 17 29t32 3t4 15 1t2 13t4X8
22 1 114 18 29t32 3t4 16 5/8 13t4X8
24 1 114 19 29t32 314 17 5t8 13t4X8
26 1 114 20 29t32 3t4 18 314 13/4X9
28 1 114 22 29t32 3t4 20 5t8 2X8
30 1 114 23 29t32 314 21 314 2X8
32 1 114 24 29t32 3t4 22 314 2X8
34 1 114 25 29t32 3t4 23 3t4 2X9
36 1 114 26 29t32 314 24 3t4 2X9

NOTES: 1. All dimensions are in inches and are provided for user information only.
2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
l-
2525 and 2530.
o 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
o
CD then lock in place.
)
r.rJ

U)
U)
J
OR DERING INSTRUCTIONS:
z
0 Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size
E
o
G G EXAMPLE: Part 6252-7-RlO-4"
tEV

ffi
H
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART
DATE
6252.7
9t1t2007
Hffi CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF. AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

90"

l<+

-]-l
DIRECTION
OF
Note: The temperature shown is for Design and Operating Conditions. For the Test Condi LOADING
"oorl,"
the maximum temperature is 100'F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) lor Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Gondition Level A Level B Level C Level D (see Note)
4 12000 12000 15960 18000 16800 15960
F IRV 5 12000 12000 15960 18000 16800 15960
6 12000 12000 15960 18000 16800 15960
I 12000 12000 15960 18000 16800 15960
10 12000 12000 15960 18000 16800 15960
12 12000 12000 15960 18000 16800 15960
14 12000 12000 15960 18000 16800 15960
16 12000 12000 15960 18000 16800 15960
18 12000 12000 15960 18000 16800 15960
20 12000 12000 15960 18000 16800 15960
22 12000 12000 15960 18000 16800 15960
24 12000 12000 15960 18000 16800 15960
26 12000 12000 15960 18000 16800 15960
28 12000 12000 15960 18000 16800 15960
30 12000 12000 15960 18000 16800 15960
32 12000 12000 15960 18000 16800 15960
34 12000 12000 15960 18000 16800 15960
36 12000 12000 15960 18000 16800 15960

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.

*"
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
Ptate: sA-36 are in accordance with ASME BPVC Section lll,
Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
Pin: 5A-654 TYPE 630
Nuts: SA-194 GR 2H Bergen Power Pipe Supports, Inc.
Studs: SA-193 GR 87 Product Engineering Department

Cotter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252


PART NO.
Sheet REV.
BERGEN.POWER PIPE SUPPORTS, INC. ,/N
REV Certification lof1 6252-12
OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

10"
IP
t
I
I

d6
f ---r---

t-l
PIPE STOCK
D E G P S
SIZE SIZE TXW
4 1 114 8114 29t32 3t4 5 314 11t2X7
5 1 114 8 314 29t32 314 6112 1 1t2 X7
6 1 114 91t2 29t32 314 7 118 1112X7
8 1 114 10 112 29t32 3t4 I 3/8 11t2X7
10 1 114 12 29t32 3t4 I314 11t2X8
\l{) 6 12 1 114 13 29t32 3t4 1 1 1t16 11t2X8
lEV 14 1 114 14 29t32 314 12 3t8 1314X7
16 1 1t4 15 29t32 3t4 13 3/8 X7
1 3t4
18 1 114 16 29t32 314 14112 X7
1 3t4
20 1 114 17 29t32 314 15 1t2 13t4X8
22 1 1t4 18 29t32 314 16 5/8 13t4X8
24 1 114 19 29t32 3t4 17 518, 13t4X8
26 1 114 20 29t32 314 18 3t4 13t4X9
28 1 114 22 29t32 3t4 20 5t8 2X8
30 11t4 23 29t32 314 21 3t4 2){8
32 1 114 24 29t32 3t4 22 3t4 2X8
34 1 114 25 29t3,2 3t4 23 3t4 2X9
36 1 114 26 29t32 314 24 3t4 2X9

NOTES: 1 . All dimensions are in inches and are provided for user information only.
2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
t- 2525 and 2530.
o 3.. lnstallation Note: Tension Bolts to remove all slack plus l12turn of the nut.
F
o
o, then lock in Place.
uJ
=
U)
I
z ORDERING INSTRUCTIONS:
g Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
(r
o
<" G EXAMPLE: Part 6252'12'Rl0'4"
EV

ffi
E
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART 6252-12
DATE 9t1t2007
H
rn;
Nd
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF. AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

90"

-]-t
DIRECTION
OF
Note: The temperature shown is for Design and Operating Conclitions. For the Test Condi LOADING
"oo,l"
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) lor Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
qt 4 15000 15000 19950 22500 28200 19950
F iR 5 15000 15000 19950 22500 28200 19950
6 15000 15000 19950 22500 28200 19950
8 15000 15000 19950 22500 28200 19950
10 15000 15000 19950 22500 28200 19950
12 15000 15000 19950 22sOO 28200 19950
14 15000 15000 19950 22500 28200 19950
16 15000 15000 19950 22500 28200 19950
18 15000 15000 19950 22500 28200 19950
20 15000 15000 19950 22500 28200 19950
22 15000 15000 19950 22500 28200 19950
24 15000 15000 19950 22500 28200 19950
26 15000 15000 19950 22500 28200 19950
28 15000 15000 19950 22500 28200 19950
30 15000 15000 19950 22500 28200 19950
32 15000 15000 19950 22500 28200 19950
34 15000 15000 19950 22500 28200 19950
36 15000 15000 19950 22500 28200 19950

NOTE: For use only with Mechanical Struts manufactured by Pacific Scientific Company per
bulletin PSA-4. This product must be used with shear lugs ,welded to the pipe, mounted
o
at 90 o to each other and 45 from the vertical centerline of the clamp. Supplied by others.
r cenry Inrs uuFrD
"otiffiTfi
Code. I
requirements of the applicable

Materials: The Design Report & Design Specification


r\
o
o
Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o, Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
Irl
f
a
Pin: SA-194 GR 2H
a
J
Nuts: SA-193 GR 87 Bergen Power Pipe Supports, lnc.
z Studs: 5A-36 Product Engineering Department

0
E.
o lotter pins, Washers, Retainers Exempt (NF-1 110) CONTROL REFNO. 6252
PART NO.

REV Cerlification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

lof 1 A 6252-15
OFF-AXIS PIPE CLAMP FOR STRUTS BY P.S.C.

w __+.1
D r^o.

dd
- T------ r
__t]__
tt
tt

PIPE STOCK
D E G P s SIZE TXW
SIZE
4 7t8 I 1
114 3t32 1 5 314 1 1t2X7
5 7t8 I3t4 1 3t32 1 6 1t2 1 1t2X7
6 7t8 I 1t2 1 3t32 1 7 1t8 1 1t2X7
8 7/8 10 1t2 1 3t32 1 8 7t8 1 1t2X7
10 7t8 12 1 3t32 I3t4 1 1t2X 8
6 6 12 7t8 13 1 3t32
1

1 1 1 1116 11t2X8
REV
14 7t8 14 1 3t32 1 12 3t8 1 314 X7
16 7t8 15 1 3t32 1 13 3/8 1 314 X7
18 7t8 16 1 3t32 1 141t2 13t4X7
20 7t8 17 1 3t32 1 15 1t2 13t4X8
22 7t8 18 1 3t32 1 16 5/8 13t4 X I
24 7t8 19 1 3t32 1 17 5t8 13t4 X I
26 7t8 20 1 3132 1 18 3t4 13t4 X 9
28 7t8 22 1 3t32 1 20 5t8 2X8
30 7t8 23 1 3t32 1 21 3t4 2X8
32 7t8 24 1 3t32 1 22 3t4 2X8
34 7t8 25 1 3t32 1 23 3t4 2X9
36 7t8 26 1 3t32 1 24 3t4 2X9

F-
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with PSA-10.
o
o) 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
uJ
f then lock in place.
a
a
J
z ORDERING INSTRUCTIONS:
q Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
IE
o
G G EXAMPLE: Part 6252-15-R/0-4"
lEV

ri\f, BERGEN-POWER PIPE SUPPORTS INC. PART 6252-15


Hd
fl CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
ffi
E
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES


dd I T -'

+t
DIRECTION
OF
Note: The temperature shown is for Design and Operating Conditions. For the Test Condi LOADING
"oorl.
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
4 25000 25000 33250 37500 35000 0
F E 5 25000 25000 33250 37500 35000 33250
6 25000 25000 33250 37500 35000 33250
I 25000 25000 33250 37500 35000 33250
10 25000 25000 33250 37500 35000 33250
12 25000 25000 33250 37500 35000 33250
14 25000 25000 33250 37500 35000 33250
16 25000 25000 33250 37500 35000 33250
18 25000 25000 33250 37500 35000 33250
20 25000 25000 33250 37500 35000 33250
22 25000 25000 33250 37500 35000 33250
24 25000 25000 33250 37500 35000 33250
26 25000 25000 33250 37500 35000 33250
28 25000 25000 33250 37500 35000 33250
30 25000 25000 33250 37500 35000 33250
32 25000 25000 33250 37500 35000 33250
34 25000 25000 33250 37500 35000 33250
36 25000 25000 33250 37500 35000 33250

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.

*"
equirements of the applicable Code. I
Materials: The Design Report & Design Specification
F-
o Plate: S4-36 are in accordance with ASME BPVC Section lll,
o
o, Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
tu
f
a
Pin: 5A-654 TYPE 630
a Nuts: SA-194 GR 2H Bergen Power Pipe Supports, lnc.
J
z Studs: SA-193 GR 87 Product Engineering Department
o
tr CONTROLREFNO. 6252
o Cotter pins. Washers, Retainers Exempt (NF-1110)
PARI NO.

REV
P

Gertification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

l_of 1 A 6252-25
a

OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

10"
;P
I
D pno.

--r

l-l
tt

PIPE STOCK
D E G P S
stzE SIZE TXW
5 2114 10 1 7116 1 6 7t8 1 3t4 X I
\lr)l 6 6 21t4 11 1 7116 1 I 1t8 2X8
lEV
I 2 1t4 12 1 7t16 1 9 3/8 2X9
10 2 114 13 1t2 1 7t16 1 10 5/8 2X 10
12 2 114 15 1 7t16 1 11 718 2X 11
14 21t4 16 1 7t16 1 12 1t2 2X 11
16 2114 17 17t16 1 13 5/8 2X 12
18 2 114 18 1 7t16 1 14 3t4 2X 12
20 2 1t4 19 1 7116 1 15 718 2X 12
24 2 1t4 22 17t16 1 18 1t8 2X 14
30 2 114 25 1 7t16 1 21 5t8 2X 15
36 2114 28 1 7t16 1 24 3t4 2X 16

f-
NOTES: 1 . AII dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
o
CD 2525 and 2530.
uJ
l 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
U)
a then lock in place.
J
z ORDERING INSTRUCTIONS:
g Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
E
o
G EXAMPLE: Part 6252-25-R/0-6"
lEV

fi\;
Hfl
fl
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART 6252-25
DATE 9t1t2007
CERTIFIED DESIGN REPORT SUMMARY

E\n
ru
Hd
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

90"

| +-+

rl DIRECTION
OF
Note: The temperature shown is for Design and Operating Oonditions. For the Test Condi LOADING
"ooJ"
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) lor Classes 1,2,3 & MC
Design OPERATING CONDMONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
G 4 35000 35000 46550 52500 49000 46550
RRV 5 35000 35000 46550 52500 49000 46550
6 35000 35000 46550 52500 49000 46550
8 35000 35000 46550 52500 49000 46550
10 35000 35000 46550 52500 49000 46550
12 35000 35000 46550 52500 49000 46550
14 35000 35000 46550 52500 49000 46550
16 35000 35000 46550 52500 49000 46550
18 35000 35000 46550 52500 49000 46550
20 35000 35000 46550 52500 49000 46550
22 35000 35000 46550 52500 49000 46550
24 35000 35000 46550 52s00 49000 46550
26 35000 35000 46550 52500 49000 46550
28 35000 35000 46550 52500 49000 46550
30 35000 35000 46550 52500 49000 46550
32 35000 35000 46550 52500 49000 46550
34 35000 35000 46550 52500 49000 46550
36 35000 35000 46550 52500 49000 46550

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45"from the vertical centerline of the clamp. Supplied by others.

I certify this CDRS complies with the


requirements of the applicable Code.

Materials: The Design Report & Design Specification


F*
o Plate: SA-36 are in accordance with ASME BPVC Section lll,
o
o) Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
uJ
l
a
Pin: 5A-654 TYPE 630
IJ Nuts: SA-194 GR 2H Bergen Power Pipe Supports, lnc.
z Studs: SA-193 GR 87 Product Engineering Department
g
CE
o Cotter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252
PART NO.
qKK Sheet REV.
BERGEN.POWER PIPE SUPPORTS, INC. l_of 1 /a\. 6252-35
REV Certification
OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

!<__ w ---- I

10" 1

D
;P
L
n^0.

-T

PIPE STOCK
D E G P S
SIZE SIZE TXW
C, 6 8 2 5t8 13 1 17t32 1 1t4 I 114 2X 13
IEV 10 2 5t8 14 1 17t32 1 1t4 10 1t2 2X 14
12 2 5t8 15112 1 17t32 1 1t4 11 3t4 2X 15
14 2 5t8 16 1 17t32 1 1t4 12 1t2 2X 15
16 2 5t8 17 1 17t32 1 1t4 13 5/8 2X 15
18 2 5t8 18 1 17t32 1 1t4 14 3t4 2X 15
20 2 5t8 19 1t2 1 17t32 1 1t4 15 7t8 2X 16
24 2 5t8 22 1t2 1 17t32 1 1t4 19 1t4 21t2 X 16
30 2 5t8 25 1t2 1 17t32 1 1t4 22 3t8 21t2 X 16
36 2 5t8 29 1 17t32 1 1t4 25 1t2 21t2 X 16

l-
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
o
F

o, 2525 and 2530.


IIJ
f 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
v)
I then lock in place.
J
z ORDERING INSTRUCTIONS:
(t Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
E
o
G EXAMPLE: Part 6252-35-R/0-10"
REV

ffi
fl
BERGEN-POWER PIPE SUPPORTS INC.
CDRS CATALOG INFORMATION SHEET
PART 6252-35
DATE 911t2007
CERTIFIED DESIGN REPORT SUMMARY

E7;
Hd
H
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

90"

\ {*
-Y-
64 _I-I

-
ft- DIRECTION
OF
Note: The temperature shown is for Design and Operating Conditions. For the Test Condi LOADING
"oo,l"
the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads
o
up to the temperature shown for the Operating Condition. Temperature: 650 F

DESIGN SPEC NO.: DS-6202 R3


DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) lor Glasses 1,2,3 & MC
Design OPERATING CONDMONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
G 4 50000 50000 66500 75000 94000 0
RRV 5 50000 50000 66500 75000 94000 66500
6 50000 50000 66500 75000 94000 66500
I 50000 50000 66500 75000 94000 65500
10 50000 50000 66500 75000 94000 66500
12 50000 50000 66500 75000 94000 66500
14 50000 50000 66500 7s000 94000 66500
16 50000 50000 66500 75000 94000 66500
18 50000 50000 56500 75000 94000 66500
20 50000 50000 66500 75000 94000 66500
22 50000 50000 66500 75000 94000 66s00
24 50000 50000 66500 75000 94000 66500
26 50000 50000 66s00 75000 94000 66500
28 50000 50000 66500 75000 94000 66500
30 50000 50000 66500 75000 94000 66500
32 50000 50000 66500 75000 94000 66500
34 50000 50000 66500 75000 9r1000 66500
36 50000 50000 66500 75000 94000 66500

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.

equirements of the applicable Code. I


Materials: The Design Report & Design Specification
N
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
o) Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
ul
l Pin: 5A-654 TYPE 630
U)
IJ Nuts: SA-194 GR 2H Bergen Power Pipe SupPorts, lnc.
z 3tuds: SA-193 GR 87 Product Engineering Department
g
(r
o Sotter pins, Washers, Retainers Exempt (NF-1 110) CONTROL REFNO. 6252
PAHI N(J.

REV Certification
BERGEN.POWER PIPE SUPPORTS, INC. lof
Sheet
1 A 6252-50
OFF.AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

D p^o.

PIPE STOCK
D E G P S
stzE SIZE TXW
10 21t4 14 1t4 13t4 1 1t2 10 3/8 2X 16
C 6 12 21t4 15 3t4 13t4 1 1t2 11 5/8 2X 18
lEV 14 21t4 16 3t4 1 3t4 1 1t2 123t8 2 X 19
16 21t4 17 3t4 1 3t4 1 1t2 13 1t2 2 X 19
18 21t4 18 3t4 13t4 1 1t2 14 5t8 2X20
20 21t4 20 13t4 1 1t2 157t8 21t4 X 20
22 21t4 21 3t4 13t4 1 1t2 18 21t2 X 16
24 21t4 223t4 13t4 1 1t2 19 1/8 21t2 X 16
26 21t4 23 3t4 13t4 1 1t2 20 1t8 21t2 X 16
28 21t4 25 1t2 13t4 1 1t2 221t8 23t4 X 16
30 21t4 26 3t4 13t4 1 1t2 231t4 23t4 X 16
32 21t4 27 3t4 13t4 1 1t2 241t4 23t4 X 16
34 21t4 28 3t4 13t4 1 1t2 25 3t8 23t4 X 16
36 21t4 29 3t4 13t4 1 1t2 26 3t8 23t4 X 16

l-
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
o
F

CD 2525,2530 and PSA-35 (as per bulletin PSA-4.


[!
:) 3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
ct)
a then lock in place.
J
z ORDERING INSTRUCTIONS:
(, Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
E
o
G G EXAMPLE: Part 6252-50-Rl0-12"
lEV

TFA BERGEN-POWEN PIPE SUPPORTS INC. PART 6252-50


Hd
H CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
OFF . AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

f-- 90"

-\ G-*

dd
T=-
-]-t
DIRECTION
OF
NOte: The temperature shown is for Design and Operating Conclitions. For the Test Condi LOADING
"oorl,,
the maximum temperature is 100oF. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition. Temperature: 650 'F
DESIGN SPEC NO.: DS-6202 R3
DESIGN REPORT NO.: DR-6202 R0
Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDMONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
4 60000 60000 79800 90000 112800 79800
RRV 5 60000 60000 79800 90000 112800 79800
6 60000 60000 79800 90000 112800 79800
8 60000 60000 79800 90000 1 12800 79800
10 60000 60000 79800 90000 1 12800 79800
12 60000 60000 79800 90000 1 12800 79800
14 60000 60000 79800 90000 1 12800 79800
16 60000 60000 79800 90000 1 12800 79800
18 60000 60000 79800 90000 1 12800 79800
20 60000 60000 79800 90000 1 12800 79800
22 60000 60000 79800 90000 1 12800 79800
24 60000 60000 79800 90000 1 12800 79800
26 60000 60000 79800 90000 1 12800 79800
28 60000 60000 79800 90000 1 12800 79800
30 60000 60000 79800 90000 1 12800 79800
32 60000 60000 79800 90000 1 12800 79800
34 60000 60000 79800 90000 112800 79800
36 60000 60000 79800 90000 112800 79800

NOTE: This product must be used with shear lugs ,welded to the pipe, mounted at 90'to each
other and 45ofrom the vertical centerline of the clamp. Supplied by others.

-"*ry
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
N
o
o
Plate: 54-36 are in accordance with ASME BPVC Section lll,
O) Bolts: SA-193 GR 87 Subsection NF, 2007 Edition and are on file at
)a
ul
Pin: SA-654 TYPE 630
a
J
Nuts: SA-194 GR 2H Bergen Power Pipe Supports, lnc.
z Studs: SA-193 GR 87 Product Engineering DePartment
(9
(r
o ]otter pins, Washers, Retainers Exempt (NF-1 110) CONTROLREFNO. 6252
PART NO.
\KK
REV Certification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

l-of 1 AREV.

6252-60
OFF-AXIS PIPE CLAMP FOR STRUT ASSEMBLIES

D n^o.

t-t
tt

PIPE STOCK
D E G P S
SIZE SIZE TXW
10 21t4 141t4 13t4 1 1t2 10 3/8 21t4 X 16
Jr) 6 12 21t4 15 3t4 1 3t4 1 1t2 11 5/8 2X 18
lEV 14 21t4 16 3t4 13t4 1 1t2 123t8 2X19
16 21t4 17 3t4 13t4 1 1t2 13 1t2 2X19
18 21t4 18 3t4 1 3t4 1 1t2 14 5t8 2X20
20 21t4 20 1 3t4 1 1t2 157t8 21t4X20
22 21t4 21 3t4 13t4 1 1t2 18 21t2X 16
24 21t4 22 3t4 13t4 1 1t2 19 1/8 21t2X 16
26 21t4 23 3t4 13t4 1 1t2 20 1t8 21t2X 16
28 21t4 25 1t2 13t4 1 1t2 221t8 23t4 X 16
30 21t4 26 3t4 13t4 1 1t2 23 1t4 23t4 X 16
32 21t4 27 3t4 13t4 1 1t2 24 1t4 23t4 X 16
34 21t4 28 3t4 13t4 1 1t2 25 3t8 23t4 X 16
36 21t4 29 3t4 13t4 1 1t2 26 3t8 23t4 X 16

N
NOTES: 1 . All dimensions are in inches and are provided for user information only.
o 2. This clamp is compatible with B-PPS Parts 2015,2250,2252,2420,2440,
o
o, 2525 and 2530.
3.. lnstallation Note: Tension Bolts to remove all slack plus l12lurn of the nut.
TIJ
f
U)
a then lock in place.
J
z ORDERING INSTRUCTIONS:
o Specify Part No. ,Size Designation, CDRS Rev. No.,Pipe Size .
E
o
<' G EXAMPLE: Part 6252-60-Rl0-12"
lEV

TF1; BERGEN-POWER PIPE SUPPORTS


INC. PART 6252-60
u
Ht'
CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
ffi
ru
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

DIRECTION
OF
LOADING

I Temperature: 650 'F


NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS.628O


p G DESIGN REPORT NO.:
REV Rated Loads (lbs) lor Classes 1,2,3 & MC
Design OPERANNG CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
3t4 700 700 931 1050 1300 931
1 700 700 931 1050 1300 931
11t4 700 700 931 1050 1300 931
11t2 700 700 931 1050 1300 931
2 700 700 931 1050 1300 931
21t2 700 700 931 1050 1300 931
3 700 700 931 1050 1300 931
4 700 700 931 1050 1300 931
5 700 700 931 1050 1300 931
6 700 700 931 1050 1300 931
8 700 700 931 1050 1300 931
10 700 700 931 1050 1300 931
12 700 700 931 1050 1300 931

NOTE: This product must be used with shear lugs top & bottom, mounted at 90"to each other and 450
from the vertical centerline of the clamp, supplied by others. Each pin supports the full design
condition load.

equirements of the applicable Code. I

Materials: The Design Report & Design Specification


N
o Plate: sA-36 are in accordance with ASME Section lll,
o
o, Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
UJ
Pin:

ffi
l 5A-6564 TYP. 630
U)
a
J
Nuts: SA-563 GR A Bergen Power Pipe SupPorts, lnc.
Studs: Product Engineering Department
z
CI
TE
o Cotter pins, Washers, Retainers Exempt (NF-1 110) CONTROL REF NO. 6280
PAlt I N(,.
qKK Sheet
BERGEN.POWER PIPE SUPPORTS, INC. lof /a\. 6280-.7
REV Certification 1
RESTRAINT RISER CLAMP

+ l

PIPE SIZE

L_l
-G

-.il I
Gt)
t,,
@
T
@
I
+ W

PIPE c-c D G P
STOCK
SIZE MIN MAX T w
\to 1t2
\(f)
3t4 5 24 3t4 1t2 3/8 4
REV
1 5112 24 3t4 1t2 3/8 1t2 4
1 1t4 6 24 3t4 1t2 3/8 1t2 4
1 1t2 61t2 24 3t4 1t2 3/8 1t2 4
2 7 24 3t4 1t2 3/8 1t2 4
21t2 8 24 3t4 1t2 3/8 1t2 4
3 8112 24 3t4 1t2 3/8 1t2 4
4 9 24 3t4 1t2 3/8 1t2 4
5 11 24 3t4 1t2 3/8 1t2 4
6 12 1t2 30 3t4 1t2 3/8 1t2 4
8 141t2 30 3t4 1t2 3/8 1t2 4
10 16 1t2 36 314 1t2 3/8 1t2 4 1t2
12 19 36 3t4 1t2 3/8 1t2 4 1t2

NOTES:
1 . All dimensions are in inches and are provided for user application onlv.
F-
o 2. This clamp is compatible with BPPS Parts 2015,2250,2252,2420 and 2440.
o
CD 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
uJ
f
a
q ORDERING INSTRUCTIONS:
J
Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
g
=
TT
o EXAMPLE: Part 6280-.7-R0-3"-C-C= 10"
G
lEV
BERGEN-POWER PIPE SUPPORTS PART 6280-.7
TFN
Hd
fl CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
CERTIFIED DESIGN REPORT SUMMARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

0
DIRECTION
OF
LOADING

Temperature:.$Qlf

Note: The temperature shown above is for Design and Operating Gonditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


3l
DESIGN REPORT NO.: DR-6280 RO
F E ,l Rated Loads (lbs) lor Classes 1,2,3 & MC

NOTE: This product must be used with shear lugs top & bottom, mounted at 90"to each other and 45
from the vertical centerline of the clamp, supplied by others. Each pin supports the full design
condition load.

'equirements of the applicable Code. I

Materials: The Design Report & Design Specification


Fr
o Plate: SA-36 are in accordance with ASME BPVC Section lll,
o
o, Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
uJ
Pin: 54-6564 TYP. 630

ffi
f
@
a
J
CLOUTIER Nuts: 5A-563 GR A Bergen Power Pipe SuPPorts, lnc.
Studs: Product Engineering DePartment
z
CI
(E
o Cotter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF NO. 6280

K
PART NO.
qKTA Sheet
BERGEN.POWER PIPE SUPPORTS, INC. l-of 1 6280-1.5
REV Certification
RESTRAINT RISER CLAMP

c-c
PIPE SIZE -
I

I
I
r eouio r>
oR sruDu
,_

+
@
I
e+
PIPE c-c D G P
STOCK
SIZE MIN MAX T W
{ \ct,
21t2 9 24 7t8 5t8 1t2 314 4
REV
3 10 24 7t8 5/8 1t2 3t4 4
4 11 24 7t8 5t8 1t2 3t4 4
5 12 26 7t8 5t8 1t2 3t4 4
6 13 1t2 30 7t8 5/8 1t2 3t4 4
I 15 1t2 30 7t8 5t8 1t2 3t4 5
10 17 1t2 32 7t8 5t8 1t2 314 5
12 20 34 7t8 5/8 1t2 3t4 5
14 21 36 7t8 5/8 1t2 3t4 5
16 23 1t2 38 7t8 5/8 1t2 3t4 5

NOTES:
1 . All dimensions are in inches and are provided for user application onlv.
l-
o 2. This clamp is compatible with BPPS Parts 2015,2250,2252,2420 and 2440.
o
o) 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
r,rJ
f
@
I ORDERING INSTRUCTIONS:
J
z Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
g
(r
o EXAMPLE: Part 6280-1 .5-R0-3"-C-C= 10"
F
\o
lEV
BERGEN.POWER PIPE SUPPORTS PART 6280-1 .5
TFI;
U
Irdtd
CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
rn;
H*
U
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

DIRECTION
OF
LOADING

I Temperature: 650 'F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f . For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


- DESIGN REPORT NO.: DR-6280 RO
REV Rated Loads (lbs) for Classes 1,2,3 & Mc
Design OPERATING CONDITIONS
Test Gondition
PIPE SIZE
Condition Level A Level B Level G Level D (see Note)
21t2 4000 4000 5320 6000 7500 5320
3 4000 4000 5320 6000 7500 5320
4 4000 4000 5320 6000 7500 5320
5 4000 4000 5320 6000 7500 5320
6 4000 4000 5320 6000 7500 5320
8 4000 4000 5320 6000 7500 5320
10 4000 4000 5320 6000 7500 5320
12 4000 4000 5320 6000 7500 5320
14 4000 4000 5320 6000 7500 5320
16 4000 4000 5320 6000 7500 5320

NOTE: This product must be used with shear lugs top & bottom, mounted at 90" to each other and 45"
from the vertical centerline ol the clamp, supplied by others. Each pin supports the lull design
condition load.

-"*ry
equirements of the applicable Code. I

Materials: The Design Report & Design Specification


t-
o
o
Plate: 5A-36 are in accordance with ASME BPVC Section lll,
b Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
LlJ
f
a
Pin: 5A-6564 ryP. 630
L
J
Nuts: 54-563 GR A Bergen Power Pipe Supports, lnc.
Studs: Product Englneerlng Department
z
Itr
Cotter pins, Washers, Retainers Exempt (NF-1110) CONTROLREFNO. 6280
PART NO.
Sheet
BERGEN-POWER PIPE SUPPORTS, INC. 1of 1 ,,4. 6280-4
REV Certilication
TO P${
Ii
rii
tf
l'

'1_
:1

il1il -1-il
ilOTES:
I. Al I d imens ions are in i nches.
2. D imens ions are prov i ded f or user
3. This clamp is cornpatible with B-P
Parts 2015, 2250, 2252,
2525 and 2530.

ORDERI I{G II(STRUCTIOITS :


Specify Part l{o., Load Size
ignet ion, Load Capac i ty Data.
Des
Sheet Revision No., Pipe Size
and C-C required
EXAiIPUE: Part 6280-4-nl4'6'-'-C-g=15,".

I IOiI NOTE:
}ISTALLAT
Tension bolts to remove slack
plus l/2 turn of the nut. Then
lock in place.

ItilCEI+ATTrIO}I PIPE sUPFlOnr GORP.


DltE 11-19-E7
ffi
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

DIRECTION
OF
LOADING

Temperature: 650 " F

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


7
\+
7 DESIGN REPORT NO.: DR-5280 RO
REV Rated Loads lor Classes ,2,3 & MC
Design OPERANNG CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)

4 7000 7000 9310 10500 14000 9310


5 7000 7000 9310 10500 14000 9310
6 7000 7000 9310 10500 14000 9310
I 7000 7000 9310 10500 14000 9310
10 7000 7000 9310 10500 14000 9310
12 7000 7000 9310 10500 14000 9310
14 7000 7000 9310 10500 14000 9310
16 7000 7000 9310 10500 14000 9310
18 7000 7000 9310 10500 14000 9310
20 7000 7000 9310 10500 14000 9310
22 7000 7000 9310 10500 14000 9310
24 7000 7000 9310 10500 14000 9310
26 7000 7000 9310 10500 14000 9310
28 7000 7000 9310 10500 14000 9310
28 7000 7000 9310 10500 14000 9310
28 7000 7000 9310 10500 14000 9310

NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45"
from the vertical centertine of the clamp, supplied by others. Each pin supports the full design
condition load.
rcenrylnrs uuFrD
"oto@ Code. I
equirements of the applicable

Materials: The Design Report & Design Specification


Fr
o
o
Plate: SA-36 are in accordance with ASME BPVC Section lll,
q) Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
Lll
f
a
Pin: SA-6564 TYP. 630
a
) Nuts: 5A-563 GR A Bergen Power Pipe SuPPorts, lnc,
Studs: Product Engineering Department
g
=
E
o lotter pins, Washers, Retainers Exempt (NF-1110) CONTROL REF NO. 6280
PAft I N(,.

REV Gertification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

lof 1 A 6280-7
RESTRAINT RISER CLAMP

c-c
PIPE sIzE --l I

I
-I
T I

BOLTA
ORI 5TUDZ
----->1
l* ! t,,
--T-
@ @
+
I

W
I

i
PIPE c-c D G P
STOCK
SIZE MIN MAX T W
4 141t2 25 1 1t2 7t8 3t4 1 1t2 6
6 6 5 16 28 1 1t2 7t8
7t8
3t4
3t4
1 1t2
1 1t2
7
7
IEV 6 17 1t2 30 1 112
8 20 112 30 1 1t2 7t8 3t4 1314 7
10 23 36 1 1t2 7t8 3t4 1 3t4 7
12 25 1t2 36 1 1t2 7t8 314 1314 7
14 26 1t2 36 1 1t2 7t8 3t4 1 1t2 8
16 29 48 1 1t2 7t8 3t4 1 3t4 9
18 31 48 1 1t2 7t8 3t4 1314 9
20 34 48 11t2 7t8 314 1314 9
22 36 48 1 1t2 7t8 3r4 1 1t2 10
24 37 1t2 48 1 1t2 7t8 314 1 1t2 10
26 40 50 1 1t2 7t8 314 1 1t2 10
28 42 25 1 1t2 7t8 3t4 1 1t2 10
30 44 23 1 1t2 7t8 314 1 1t2 10
36 50 60 1 1t2 7t8 3t4 1 1t2 11

N
NOTES:
o 1 . All dimensions are in inches and are provided for user application onlv.
r
o
o, 2. This clamp is compatible with BPPS Parts 2250,2252,2420,2440,2525 and 2530.
uJ
l 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
a
I
J
z ORDERING INSTRUCTIONS:
g Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
IT
o
G G EXAMPLE: Part6280-7-R0-6"-C-C=20"
lEV
PART
ffl;
Hd
fl
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET DATE
6280.7
9t112007
CERTIFIED DESIGN REPORT SUMMARY
f*l lor
llt NUCLEAR POWER PLANT STANDARD SUPPORTS

-
I , i:- - - r

0
rolo,,-i-_, DIRECTION
OF
LOADING

Temperature:-.QSf
I

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


DESIGN REPORT NO.: DR-6280 RO
REV Rated Loads (lbs) for Glasses 1,2,3 & MC

l;rr= .*T Des.is.n


t- oPERATING CONDITIONS -l r"", condition I
I I vons*ren I a" l (see Note) I

l+lrzoooltzoooltsgeolteooolzzsooltsg0ol
lsl12000lrzoooltsgeoltsoool22500l15960l
lol12000ltzoooltsgeol18000l22500l15960l -
lal12000lreooolt5960l18000l22500l15960l
I ro I 12000 I 12000 I t5960 I 18000 I 22500 | 15960 I
I rz I 12000 I 12000 I 15960 I 18000 I 22500 | 15960 I
I r+ | tzooo I tzooo I tsgeo I teooo I zzsoo I tsg0o I
I re I rzooo I tzooo I tsgso I taooo I zzsoo I tsgoo I
I rs I rzooo I tzooo | 15960 I t8000 | 22500 | 15960 |

l-.-.+
NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45
from the vertical centerline ol the clamp, supplied by others. Each pin supports the full design
condition load.
r cenrry Inrs uuFrD*tiffiT*-;
requirements of the applicable Code. I
Materials: The Design Report & Design Specification
F-
o
o
Plate: 54-36 are in accordance with ASME BPVC Section lll,
o, Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
TIJ
:)
a
Pin: SA-6564 TYP. 630
a
J
Nuts: SA-563 GR A Bergen Power Pipe Supports, lnc,
Studs: Product Engineering DePartment
z
a
(f,
o Cotter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF NO. 6280
PART NO.
\K.F
REV Certification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet
1of 1 A
FEV.
6280-12
RESTRAINT RISER CLAMP

>t D
I

Ir
-G

-->]
l

t,,
-T
@ @
I
+ W

i
PIPE c-c D G P
STOCK
SIZE MIN MAX T w
4 14112 25 1 1t2 7t8 3t4 1 1t2 6
6 \(t)
5 16 28 1 1t2 7t8 3t4 1 112 7
REV 6 17 1t2 30 1 1t2 7t8 314 1 1t2 7
8 20 1t2 30 1 1t2 7t8 3t4 1 3t4 7
10 23 36 1 1t2 7t8 3t4 1 3t4 7
12 25 1t2 36 1 1t2 7t8 3t4 1 3t4 7
14 26 1t2 36 1 1t2 7t8 3t4 1 1t2 8
16 29 48 1 1t2 7t8 3t4 1 3t4 9
18 31 48 1 1t2 7t8 3t4 13t4 I
20 34 48 1 112 7t8 314 13t4 9
22 36 48 1 1t2 7t8 3t4 1 1t2 10
24 37 112 48 1 1t2 7t8 314 1 1t2 10
26 40 50 1 1t2 7t8 3t4 1 112 10
28 42 25 1 1t2 7t8 3t4 1 1t2 10
30 44 23 1 1t2 7t8 3t4 1 1t2 10
36 50 60 1 1t2 7t8 314 1 1t2 11

F-
NOTES:
o 1 . All dimensions are in inches and are provided for user application onlv.
o
F

o, 2. This clamp is compatible with BPPS Parts 2250,2252,2525 and 2530.


r!
f 3. Tension bolts to remove slack plus l12turn of nut. Then lock in place.
U)
a
J
ORDERING INSTRUCTIONS:
z
Itr Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
o
G G EXAMPLE: Part6280-12-R0-6"-C-C= 20"
lEV
PART 6280-12
rn;
Hd
fl
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET DATE 911t2007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

DIRECTION
OF
LOADING

Temperature:1Q5O '' E

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


DESIGN REPORT NO.: DR-6280 RO
REV Rated Loads (lbs) lor Glasses 102,3 & MC
Design OPERANNG CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level G Level D (see Note)
6 25000 25000 33250 37500 47000 33250
I 25000 25000 33250 37500 47000 33250
10 25000 25000 33250 37500 47000 33250
12 25000 25000 33250 37500 47000 33250
14 25000 25000 33250 37500 47000 33250
16 25000 25000 33250 37500 47000 33250
18 25000 25000 33250 37500 47000 33250
20 25000 25000 33250 37500 47000 33250
22 25000 25000 33250 37500 47000 33250
24 2s000 25000 33250 37500 47000 33250
26 25000 25000 33250 37500 47000 33250
28 25000 25000 33250 37500 47000 33250
30 25000 25000 33250 37500 47000 33250
36 25000 25000 33250 37500 47000 33250

NOTE: This product must be used with shear lugs top & bottom, mounted at 90'to each other and 45"
lrom the vertical centerline ol the clamp, supplied by others. Each pin supports the full design
condition load.
I certify this CDRS complies with the I
requirements of the applicable Code. I

Materials: The Design Report & Design Specification


N
o Plate: SA-36 are in accordance with ASME BPVC Section lll,
o
o) Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
UJ
Pin: 5A-6564 TYP. 630

ffi
:)
U)
a I CLOUTIER Nuts: SA-563 GR A Bergen Power Pipe SuPPorts, lnc.
-J Studs: Product Engineering Department
z
o
E
o Cotter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF NO. 6280
PART NO.
qKK BERGEN.POWER PIPE SUPPORTS, INC.
Sheet REV.

REV Certification Lof 1 /a\ 6280-25


RESTRAINT RISER CLAMP

c-c
PTPE SIZE
I

--T
@ @
+ I
+ W

PIPE c-c STOCK


D G P
SIZE MIN MAX T W
6 20 1t2 30 2114 1 3/8 1 2 7
\to s 8 23 35 2114 1 3/8 1 2 7
tEV
10 25 112 42 2114 1 3/8 1 2 7
12 27 112 42 2114 1 3/8 1 2 7
14 28 112 42 2114 1 3/8 1 2 8
16 31 112 48 2114 1 3/8 1 2 I
18 34 48 2114 1 3/8 1 2 9
20 36 48 21t4 1 3/8 1 2 I
22 38 1t2 48 2114 1 3/8 1 2 10
24 40 112 51 21t4 1 3/8 1 1 314 10
26 42 112 60 2114 1 3/8 1 2 10
28 45 60 21t4 1 3/8 1 2 10
30 47 60 21t4 1 3/8 1 2 10
36 53 63 2114 1 3/8 1 1 314 11

r-
NOTES:
O 1 . All dimensions are in inches and are provided for user application onlv.
r
o
O) 2. This clamp is compatible with BPPS Parts 2250,2252,2420,2440,2525 and 2530.
3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
LrJ
f
U)
a
J
z ORDERING INSTRUCTIONS:
E Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
cc
o
<" G EXAMPLE: Part 6280-25-R0-8"-C-C= 28"
IEV
BERGEN-POWER PIPE SUPPORTS PART 6280-25
Hd
rilfl,
fl CDRS CATALOG INFORMATION SHEET DATE 911t2007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
RAINT RISER CLAMP

0
DIRECTION
OF
LOADING

Temperature: 650 " F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-6280 R0


q9 DESIGN REPORT NO.: DR-6280 RO
REV Rated Loads (lbs) lor Classes 1,2,3 & MC
CONDITIONS
F;T.ff;:fl:" I
oPERAT|NG I Test Condition I
(see Note) l
lsl35000l
. 3s000 I 46550 I 52500 I 65800 | 46550 I

lalssoool 3s000 I +esso I szsoo I 65800 | 465s0 I


3s000 | 46ss0 | 52s00 I 65800 | 46550 I
I tz I ssooo I 35000 I 46s50 I 52500 | 65800 I 465s0 |
.

I r+ |
gsooo 35000 | 465s0 | 52500 I 65800 | 46550 |
I ro I gsooo I
I 35000 | 46s50 I 52500 | 6s800 | 46550 |
. 35000 I +osso I szsoo I 65800 | 46550 I
II zo I gsooo 35000 | 46550 | 52500 | 65800 | 46s50 |
. zz I gsooo
I
I 35000 I 46550 I 52500 | 65800 | 46550 |
I z+ I
.
gsooo I 35000 I 465s0 I SZSOO I 65800 | 46550 I
I
. zs I 35000 I 35000 I +osso I szsoo I 6s800 I 46550 I
I za I 35000 35000 I +0sso I s2500 I 65800 I 46550 |
go I
. I

I ge gsooo
gsooo
I 35000 I 46550 I s2500 I 65800 | 46550 I
I I I

NOTE: This product n nust be used with shear lugs top & bottom, mounted at 90'to each other and 45

lrom the vertir cal centerline of the clamp, supplied by others. Each pin supports the full design
condition load,
I certify this CDRS complies with the I

requirements of the applicable Code. I

Materials: The Design Report & Design Specification


F-
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o
b Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
ul
Pin: 5A-6564 TYP. 630

ffi
f
a
a
J
CLOUTIER Nuts: 54-563 GR A Bergen Power Pipe SuPPorts, Inc.
Studs: Product Engineering DePartment
z
0
(E
o Cotter pins, Washers, Retainers Exempt (NF-!!19L CONTROL REF NO. 6280
PAffT NO.

REV Certification
BERGEN-POWER PIPE SUPPORTS, INC, Lof 1
Sheet
A 6280-35
RESTRAINT RISER CLAMP

->l

-I
t
T-i
BoLra
R STUD@
OR -J l<-
I

! t,,
@ @
-r
+ I
+ W

L
PIPE c-c P
STOCK
D G
SIZE MIN MAX T W
6 21 1t2 32 2 1 1t2 1 114 2 12
g
\lf)

tEV
I 24 36 2 1 112 1 114 2 14
10 26 1t2 38 2 1 112 1 114 2 15
12 29 41 2 1 1t2 1 114 2 16
14 31 1t2 42 2 1 1t2 1 114 2 16
16 34 47 2 1 1t2 1 114 2 18
18 36 48 2 1 1t2 1 114 2 18
20 38 50 2 1 1t2 1114 2 18
22 40 53 2 1 1t2 1114 2 18
24 42 1t2 53 2 1 1t2 1 114 2 18
26 44 112 66 2 1 112 11t4 21t4 20
28 46 112 66 2 1 1t2 1 1t4 21t4 20
30 48 112 66 2 1 1t2 1 1t4 2114 20
36 55 66 2 1 1t2 1 1t4 21t4 20

l-
NOTES:
o 1 . AII dimensions are in inches and are provided for user application onlv.
o
ct 2. This clamp is compatible with BPPS Parts 2250,2252,2525 and 2530.
tIl
l 3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
a
a
J
OR DERING INSTRUCTIONS:
z
g Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
(f
o
G G EXAMPLE: Part 6280-35-R0-14"-C-C = 32"
REV

BERGEN.POWER PIPE SUPPORTS PART 6280-35


rF\;
Hd
fl CDRS CATALOG INFORMATION SHEET DATE 911t2007
GERTIFIED DESIGN REPORT SUMMARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
RESTRAINT RISER CLAMP

DIRECTION
OF
LOADING

Temperature: 650 'F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100 f.For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO,: DS-6280 R0


DESIGN REPORT NO.: DR-6280 RO
REV Rated Loads for ctasses 1,2.3 & MC
Design OPERANNG CONDII1ONS
PIPE SIZE Test Condition
Condltion Level A Level B Level C (see Note)
Level D
10 60000 60000 79800 90000 112800 79800
12 60000 60000 79800 90000 112800 79800
14 60000 60000 79800 90000 112800 79800
16 60000 60000 79800 90000 112800 79800
18 60000 60000 79800 90000 112800 79800
20 60000 60000 79800 90000 112800 79800
22 60000 60000 79800 90000 1 1 2800 79800
24 60000 60000 79800 90000 112800 79800
26 60000 60000 79800 90000 112800 79800
28 60000 60000 79800 90000 112800 79800
30 60000 60000 79800 90000 112800 79800
36 60000 60000 79800 90000 112800 79800

NOTE: This product must be used with shear lugs top & bottom, mounted at 90.to each other and 45"
from the vertical centerline of the clamp, supplied by others. Each pin supports the full design
condition load.
I certify this CDRS complies wimrn-ll
requirements ol the applicable Code. I

ro Materials: The Design Report & Design Specification


rlate: 5A-36 are in accordance with ASME BPVC Section lll,
o
b 3olts: SA-307 GR B Subsection NF. 2007 Edition and are on file at
tIl
f
a
rin: 5A-6564 TYP. 630
a
J
\,luts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
z ituds: Product Engineering Department
Itr
o )otter pins, Washers, Retainers Exempt (NF-1 1 10) CONTROL REF NO. 6280
K Sheet rAr I NU.
BEBGEN-POWER PIPE SUPPORTS, INC.
REV Certilication 1of 1 ,4. 6280-60
RESTRAINT RISER CLAMP

c-c

I G

I T
t

I G1

PA

@ @
I
+
PIPE c-c D P
STOCK
G
SIZE MIN MAX T W
\lJ) \(f)
10 29 1t2 40 2 3t4 1 11t16 1 1t2 2 3t4 16
REV 12 32 44 2 3t4 1 11t16 1 1t2 21t2 18
14 33 48 2 3t4 1 1 1/16 1 1t2 21t2 20
16 36 49 2 3t4 1 1 1/16 1 1t2 21t2 20
18 38 50 2 3t4 1 11t16 1 1t2 21t2 20
20 40 51 2 3t4 1 11t16 1 1t2 21t2 20
22 43 56 2 3t4 1 11t16 1 1t2 2 3t4 20
24 45 1t2 56 2 3t4 1 11t16 1 1t2 21t2 22
26 47 1t2 66 2 3t4 1 11t16 1 1t2 2 3t4 22
28 49 1t2 66 2 3t4 1 11t16 1 1t2 2 3t4 22
30 51 112 66 2 3t4 1 11t16 1 1t2 2 3t4 22
36 58 68 2 3t4 1 1 1/16 1 1t2 2 3t4 22

f-
NOTES:
O 1 . All dimensions are in inches and are provided for user application onlv.
o
ct 2. This clamp is compatible with BPPS Parts 2250,2252,2421,2440,2525 and 2530.
3. Tension bolts to remove slack plus l12lurn of nut. Then lock in place.
r.rJ
l
q
U)
J
z ORDERING INSTRUCTIONS:
g Specify Part No. , Load Size Designation, CDRS Rev. No. Pipe Size and C-C required.
tE
o
G { G EXAMPLE: Part6280-60-R0-16"-C-C=38"
lEV

ffi
fl
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART 6280-60
DATE 9t1t2007
tit I' d
E
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

R'SER CUMP. PART NUMBER630/0,.,73K

s .lll lll .P
DIRECTION
OF
LOADING

I
I

Temperature: 6500F

No"t
For' the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6300
temperatures in fre Test Condition, use Level B loads up to the temperature
Design Report No. DR-6300
shown for the Operating Condition.

Operatins Conditions Test Condition


Size Design Condition (see Note)
Level A Level B Level G Level D
3t4 730 730 971 1,095 1,278 971
1 730 730 971 1,095 1,278 971
11t4 730 730 971 1,095 1,27E 971
1112 730 730 971 1,095 1,278 971
2 730 730 971 1,095 1,278 971
21//2 730 730 971 1,095 1,278 971
3 730 730 971 1,095 1,278 971
4 730 730 971 1,095 1,278 971
5 730 730 971 1,095 1,278 971
6 730 730 971 1,095 1,278 971
8 730 730 971 1,095 1,278 971
t0 730 730 971 1,095 1,278 971
12 730 730 971 1,095 1,278 971
Rated Loads (lbs) for Classes 1,2,3 &MC
This product must be used with shear lugs, mounted at 900 to each other and 450
from the vertical centerline of the clamp, lugs will be supplied by others. Each pin
supprts the full design condition.

I cenify this CDRS comflies with he CONTROLREFNO. 6300


requirements of the apflicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: SA-193 87
Bergen Power Pipe Supports,lnc.
Studs: N/A
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REV|St0NS
/J, Oriqinal lssue 10/27109 /3\
A-tu/,&"fr /1\
$EAL vdhr/aglslcNED /i /s\

BERGEAJ POWER PIPE SUPPORTS, INC, SHEET 1 0F 1 REV.


A PART N0. 6300..73
CDRS CATALOG INFORMATION SHEET

RISER CLAMP . PART NUMBER 6300..73K

PIN to PIN (C-C)

L _+
T
r
--l
G
_1

PIN O

.lll .
-1

p W
I

lll I

-J

PIPE SIZE
c.c D
PIN VW. LBS.
\J
sTocK slzE
MIN MAX DIA. (MAX C.Cl T W
3t4 6 18 1 1t2 18 3t4 1t2 3

1 6112 18 1 1t2 18 3t4 1t2 3

1114 7 18 1 1t2 18 3t4 1t2 3

1112 7 1t2 18 1 112 18 3t4 1t2 3

2 I 24 1 1t2 31 3t4 1t2 4

2112 I 24 1 1t2 31 3t4 1t2 4

3 9112 24 1 112 32 3t4 112 4

4 101t2 24 1 1t2 32 3t4 1t2 4

5 12 30 1 1t2 49 3t4 5/8 4

6 13112 30 1 1t2 50 3t4 5/8 4

8 16 36 1 1t2 60 3t4 5/8 4

10 18112 48 1 1t2 79 3t4 5t8 4

'12 20112 48 1 1t2 81 3t4 5/8 4

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) For use with BPPS parts 5130 and 5131 eyenuts.

ORDERING INSTRUCTIONS :

Specify: Part Number, CDRS Revision Number, Pipe Size and C-C dimension.

DGMPLE: 6300-.73-R/04" C-C= 20"

REVISIONS
lssue 10/27109

PART N0. 6300..73


BERGEN POWER PIPE SUPPORTS,
'NC'
tit r, *b
CERTIFIED DESIGN REPORT SUMMARY

NUGLEAR POWER PLANT STANDARD SUPPORTS


for

R'SER CLAMP . PART NUMBER 6300.1,35K

s .lll lll
.s
DIRECTION
OF
LOADING

Temperature: 6sooF

Nottt
,0l' the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96300
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6300
shown for the Operating Condition.

Operating Conditions Test Condition


Size Design Condition
Level A Level B Level C Level D {see Note)
3//4 1,350 1,350 1,796 2,025 2,363 1,796
1 1,350 1,350 1,796 2,025 2,363 1,796
11t4 1,350 1,350 1,796 2,025 2,363 1,796
11t2 1,350 1,350 1,796 2,025 2,363 1,796
2 1.350 1,350 1,796 2,025 2.363 1,796
2112 1,350 1,350 1,796 2,025 2.363 1,796
3 1,350 1,350 1,796 2,025 2,363 1,796
4 1,350 1,350 1,796 2,025 2,363 1,796
5 1,350 1,350 1,796 2,025 2,363 1,796
6 1,350 1,350 1,796 2,025 2,363 1,796
I 1,350 1,350 1,796 2,025 2,363 1,796
10 1,350 1,350 1,796 2,025 2,363 1,796
12 1,350 1,350 1,796 2,025 2.363 1,796
Rated Loads (lbs) for C/asses 1,2,3 &MC

This product must be used with shear lugs, mounted at 900 to each other and 450
from the vertical centerline of the clamp, lugs will be supplied by others, Each pin
supports the full design condition.

I certify this CDRS complies with the


CONTROL REF NO. 6300
rcquirements of lhe applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: SA-193 87
Bergen Power Pipe Suppods, Inc.
Studs: N/A
Product Engineering DePartment
Exempt Cotter pins, Washers, Retainers (NF-2121)
REV|SIONS
/il /3\
etLl'Affi Oriqinal lssue 1 0/27109
/n
Senr 1ru722/o7lslGNED /z\ /i
BERGEAJ POWERPIPE SUPPORTS, NC, SHEET 1 OF 1 REv.
a PART N0. 6300.1.35
lit r, d
b
CDRS CATALOG INFORMATION SHEET

R'SER CUMP . PART NUMBER 6300-1,35K

__J

-t
PIN O

.il| lll
. p
--l

_J
W
I

c-c D
PIN WT. LBS.
IJ
STOCK SIZE
PIPE SIZE (MAX C-C) W
MIN ruAx DIA. T
3t4 7 24 1 1t2 34 3t4 3t4 3

1 8 24 1 1t2 34 3t4 3t4 3

1114 8112 24 1 1t2 35 3t4 3t4 3

11t2 o 24 1 1t2 35 314 3t4 3

2 9112 24 1 1t2 35 3t4 314 4


2112 101t2 36 1 1t2 67 314 3t4 4
3 11 36 1 1t2 67 3t4 3t4 4
4 121t2 36 1 1t2 68 3t4 314 4

5 14 36 1 1t2 70 3t4 3t4 4

6 15 36 1 1t2 71 3t4 314 4

I 16 36 1 1t2 73 314 3t4 4


10 18 112 48 1 1t2 119 314 3t4 4

12 21 48 1 1t2 122 314 3t4 4

NOTES:
1.) All dimensions are in inches.
2,) Dimensions are provided for user application only'
3.) For use with BPPS parts 5130 and 5131 eyenuts.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Pipe Size and GC dimension.

E)(AMPLE: 6300-1.35-R/0-4' C-C = 20"

REVISIONS
/r\ Oriqinal lssue 1 0/27109 /t\
i,r\ /il
/z\ /il
BERGEN POWER PIPE SUPPORTS, INC. SHEETl OF 1 REV.
A PART N0. 6300.1.35
tit f' A
t
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

R'SER CUMP . PART NUMBER 6300.3,23K

s .lll il|. P
DIRECTION
OF
LOADING

Temperature: 6500F

Nottt
For. the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. D96300
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6300
shown forthe Operating Condition.

Operatins Conditions Test Condition


Size Design Condition (see Notel
Level A Level B Level C Level D
2112 3,230 3,230 4,296 4,845 5,653 4,296
3 3,230 3,230 4,296 4,845 5,653 4,296
4 3,230 3,230 4,296 4,845 5,653 4,296
5 3,230 3,230 4.296 4,845 5,653 4,296
6 3.230 3,230 4.296 4,845 5,653 4,296
8 3,230 3,230 4,296 4.U5 5,653 4,296
10 3,230 3,230 4,296 4,945 5,653 4,296
12 3,230 3,230 4,296 4,845 5,653 4,296
14 3,230 3,230 4,296 4,845 5,653 4,296
16 3.230 3,230 4,296 4,845 5,653 4,296
Rated loads (bs) for C/asses 1,2,3 & MC

This product must be used with shear lugs, mounted at 900 to each other and 450
from the vertical centerline of the clamp, lugs will be supplied by others. Each pin
supports the full design condition,

I certify this CDRS complies with fie CONTROLREFNO. 6300


rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-36
accordance with ASME BPVC Section lll, Subsection
Bolts: SA-307 Gr B
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: SA-193 87
Bergen Pawer Pipe Sup ports, lnc.
Studs: N/A
Product Engineering Depailment
ExempL Cotter pins, Washers, Retainers (NF-2121)
REVISIONS
/o\ Oriqinal lssue 10/27109 /s\
A /r\
SEAL Va/L2/ot ISIGNED /t\ /t
BERGEfV POWER PIPE SUPPORTS, INC, SHEETl OF 1 REV.
A PART N0. 6300'3.23
Jr-
,,J dT, CDRS CATALOG INFORMATION SHEET
t

R'SER CLAMP . PART NUMBER 6300.3.23K

PIN to PIN (C-C)

L _l
J- u
-t
PIN O

.il| lll
. p I I

__l

PIPE SIZE
c.c D
PIN
IJ
STOCK SIZE
MIN MAX DIA. T W
21t2 11112 36 1 3t4 7t8 1 6
3 121t2 36 1 3t4 1118 1 6
4 14 36 1 3t4 11t8 1 6
5 15 36 I 3t4 11t8 1 6
6 161t2 36 1 3t4 11t8 1 6
8 18112 36 1 3t4 11t8 1 6
10 211t2 48 1 3t4 11t8 11t4 6
12 24 48 1 3t4 1118 11t4 6
14 25 60 1 3t4 11tB 1 1t4 6

16 27 60 1 3t4 1 1t8 11t4 6

NOTES:
1.) All dimensions are in inches. :

2.) Dimensions are provided for user application only.


3.) For use with BPPS parts 5130 and 5131 eyenuts.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, Pipe Size and C-C dimension.

E)(AMPLE: 6300-3.23-R/0-4" C-C = 20"

REVISIONS
vr
/r\ /^
A /i
BERG EN POWER PIPE SUPPORTS, SHEET 1 0F 1 REV.
A PART NO. 6300-3.23

'NC,
tit*T, H
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

PIPE STMP . PART NUMBER 6UO

DIRECTION
OF
LOADING

Temperature: 4000F

*ottt
For. the test condition (Hydro) the maximum temperature is 1000F, For higher
Design Spec. No. DS-6440
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6440
showrt for the Operating Condition,

Operating Gonditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
1t2 1,270 1,270 1.689 1.905 2.386 1,689
314 1.045 1,045 1,390 1.568 1.964 1,390
1 850 850 1,131 1,275 1,597 1.131
11t4 2,265 2,265 3,012 3,398 4,256 3,012
1112 2,015 2,015 2,680 3,023 3,786 2,680
2 1,620 1,620 2,155 2,430 3,0M 2,155
2112 2,385 2,385 3,172 3,578 4,481 3,172
3 2,630 2,630 3.498 3,945 4.942 3,498
4 2,060 2,060 2,740 3,090 3,871 2,740
5 2,095 2,095 2,796 3,143 3,937 2,786
6 2,115 2,115 2,813 3,173 3,974 2,813
8 1,630 1,630 2,168 2,M5 3,063 2,168
10 2,730 2,730 3.631 4.095 5,130 3,631
12 3,320 3,320 4,416 4.980 6.238 4.416
Ratedloads (lbs) for Classes 1,2,3 & MC
I certify this CDRS complies with the
CONTROL REF NO. 6440
requkements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: 5A-36
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Studs: N/A
Bergen Power Pipe Supporfs , lnc.
Product Engineering Department
Exempt N/A
REV|S|ONS
/t
f,n*K,e/e /d\ I Oriqinal lssue 1 0i27l09
/t
/i
sEat lq2z/o? lslGNED /z\

BERGETV POWERPIPE SUPPORTS, INC. SHEET 1 OF r REv. a PARTNO. 6440


CDRS CATALOG INFORMATION SHEET

PIPE STRAP . PART NUMBER 6440

I
I

r-_==-
l

PIPE SIZE A B T W

1t2 I 29t32 1t4 2

3/i4 1 3t16 1 1t8 1t4 2

1 1 7t16 1 3/8 1t4 2

1114 113t16 125t32 3/8 3

1112 2 131t32 3t8 3

2 2 112 2 7116 3/8 3

21//2 3 215116 1t2 3

3 3 5/8 3 9/16 1t2 4

4 4 518 4 9t16 1t2 4

5 s 11116 5 5/8 112 5

6 6 314 611116 1t2 6

8 B 314 8 11/16 112 6

10 10 718 10 13/16 5/8 I


12 12 718 1213116 3t4 8

NOTES:
1.) All dimensions are in inches.
2,) Dimensions are provided for user application only'
3.) A full penetration weld on both sides can be used in lieu of a fillet weld.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

E/.AMPLE: 6440-R/0-4"

al lssue 10127109

BERG EN POWER PIPE SUPPORTS, INC,


tit r, N
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

PIPE STRAP. PART NUMBER644f

DIRECTION
OF
LOADING

Temperature: 4000F

Nott'
Fo, the test condiilon (Hydro)the maximum temperature is 1000F, For higher
Design Spec. No. DS-6440
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6440
shown for the Operating Condition.

Operatinq Gonditions Test Condition


Size Design Condition (see Note)
Level A Level B Level C Level D
1//2 847 847 1,127 1,271 1,694 847
3t4 697 697 927 1,046 1,394 697
1 567 567 7il 85'l 1,134 567
1114 1.510 1,510 2,008 2,265 3,020 1,510
11t2 1,343 1,343 1,786 2,015 2,686 1,343
2 1,080 1,080 1,436 1,620 2,160 1,080
21t2 1,590 1,590 2,115 2,385 3,180 1,590
3 1,753 1,753 2,331 2,630 3,506 1,753
4 1,373 1,373 1,826 2,060 2,746 1,373
5 1,397 1,397 1,858 2,096 2,794 1,397
6 1,410 1,410 1,875 2,115 2,820 1,410
8 1,087 1,087 1,446 1,631 2,174 1,087
10 1,820 1,820 2,421 2,730 3,640 1.820
12 2,213 2,213 2.943 3,320 4,426 2,213
Rated Loads ilbd for C/asses 1,2,3 &MC
I certify this CDRS comflies with $e CONTROLREFNO. 6441
rcquirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: SA-240 TYP 304
accordance with ASME BPVC Section lll, Subsection
Bolts: N/A
NF 2007 Edition and are on file at:
Nuts: N/A
Pin: N/A
Bergen Power Pipe Suppods, lnc.
Studs: N/A
Product Engineering Department
Exempt N/A
REVISIONS
/o\ Orioinal lssue 10/27109 /3\
t*h4.M.6 /i /\
/i
SEAI lp/z2/al lslGNED /I
BERGEfV POWERPIPE SUPPORTS, INC, SHEET I OF 1 REV.
A PART NO, 6U1
titr, d
CDRS CATALOG INFORMATION SHEET

-
PIPE SIMP . PART NUMBER644|

yyJ I

PIPE SIZE A B T W

11,2 1 29t32 1t4 ll


314 1 3/16 1 1t8 1t4 2
1 1 7116 1 3/8 1t4 2
11//4 113t16 125t32 3/8 3

11/,2 2 131132 3/8 3

2 2 112 2 7t16 3/8 3

21/,2 3 215t16 1t2 3

3 3 5/B 3 9/16 1t2 4

4 4 5/8 4 9t16 1t2 4


5 511t16 5 5/8 112 5

6 6 3/4 611t16 1t2 6

I 8 3/4 I 11/16 112 6

10 10 718 10 13/16 5/8 8

12 12 718 1213116 3t4 I

1.) All dimensions are ih inches.


2.) Dimensions are provided for user application only.
3.) A full penetration weld on both sides can be used in lieu of a fillet weld.

ORDERING INSTRUCTIONS :
Specify: Part Number, CDRS Revision Number, and Pipe Size.

EMMPLE: 6441-R/0-4"

REVISIONS
/il Oriqinal lssue 1 0/27109 ii
/N
A /)
BERGEN POWER PIPE SUPPORIS, INC. SHEET 1 OF 1 REV. A PARTNO. 6441
titf' #
a
CERTIFIED DESIGN REPORT SUMMARY

NUCLEAR POWER PLANT STANDARD SUPPORTS


for

LONG TANGENT U.BOLT . PART NUMBER 6500

Condition I

DIRECTION OF LOADING DIRECTION OF LOADING


.:
I Temperature: 6500F
I

Nottt
Fol. the test condition (Hydro) the maximum temperature is 1000F. For higher
Design Spec. No. DS-6500
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6500
shoum for the Operating Condition.

Desiqn Condition Operating Gonditions Test Condition


Size
Cond. I Cond.ll Level A Level B Level G Level D (see Note)
112 600 240 600 240 790 310 900 360 1,200 480 790 310
3//4 690 210 690 210 910 270 1,030 310 1,380 420 910 270
1 1,070 150 1.070 150 1,420 200 1,600 220 2,140 300 1,420 200
11t4 1,290 160 1,290 160 1.710 210 1,930 240 2,580 320 1,710 210
11t2 1,150 130 1,150 130 1.530 170 1,720 190 2,300 260 1,530 170
2 1,170 120 1,170 120 1,550 160 1,750 180 2,340 240 1,550 160
21//2 2,010 170 2,010 170 2,670 220 3,010 250 4,020 340 2,670 220
3 2,920 140 2,920 140 3,880 180 4,390 210 5,840 280 3,880 180
31t2 1,850 120 1,850 120 2,460 160 2,770 180 3,700 240 2,460 160
4 3,040 110 3,040 110 4.040 140 4,560 160 6,080 220 4,040 140
5 2,830 90 2,830 90 3,760 120 4,240 130 5,660 180 3,760 120
6 4,1 30 150 4,130 150 5,490 200 6.190 220 8,260 300 5,490 200
Rated Loads (lbs) for Classes 1,2,3 &MC
Loads for Condition I are listed first, Condition ll are listed second.
For simultaneous loading: Condition I Load .@
ConditionlAllowable ConditionllAllowable

lcertify this CDRS comdies wifi fie CONTROL REF NO. 6500
requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: N/A
accordance with ASME BPVC Section lll, Subsection
U-Bolt 5A-36, A-108 1018 CW (CC N-249)
NF 2007 Edition and are on file at:
Nuts: 5A-563 Gr A
Pin: N/A
Bergen Power Pipe Suppodq lnc.
Studs: N/A
Product Engineering Department
Exempl N/A
REVISIONS
/; Orioinal lssue 1 0/27109 /J
{,4.>/,Mr.ffi /r\ /t
$EAL Va/lt/ag lslcNED /) /5\

BERGEAJ POWER PIPE SUPPORTS, INC, SHEET 1 OF 2 REV.


A PART NO. 6500
CERTIFIED DESIGN REPORT SUMMARY
ti7 ,, d
b
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

LO'VG IA'VGE VT U.BOLT . PART NUMBER 6500

Plate
Supplied
by Others

Condition I

DIRECTION OF LOADING DIRECTION OF LOADING

I Temperature: 6500F
I

Nottt
Fo, the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No, D96500
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6500
shown for the Operating Condition,

Detisn Condition Operating Conditions Test Condition


Size (see Note)
Cond.I Cond.ll Level A Level B Level C Level D

I 6,490 120 6,490 120 8,630 160 9,730 180 12,980 240 8,630 160
10 9,280 180 9,280 180 12,340 230 13,920 270 18,560 360 12,340 230
12 12,170 280 12.170 280 1 6,1 80 370 18,250 420 24,340 560 16,180 370
14 12,550 250 12,550 250 16,690 330 18,820 340 25,100 500 16,690 330
16 13,370 200 13,370 200 17,780 260 20,050 300 26,740 400 17,780 260
18 12,170 250 12,170 250 16,180 330 18.250 370 24,340 500 16,180 330
20 14,660 260 14,660 260 19,490 340 21,990 390 29.320 520 19,490 340
24 12,930 230 12,930 230 17,190 300 19,390 340 25,860 460 17.190 300
26 15,350 190 15,350 190 20,410 250 23,020 280 30,700 380 20,410 250
28 15.850 180 15,850 180 21,080 230 23,770 270 31,700 360 21,080 230
30 15,790 130 15,790 130 21.000 170 23,680 190 31,580 260 21,000 170
36 12,070 150 12,070 150 16,050 200 18.100 220 24,140 300 16,050 200
Rated loads (lbs) for Classes 1,2,3 & MC
Loads for Condition I are listed first, Condition ll are listed second.
Forsimultaneous loading: Condition I Load @
ConditionlAllowable^ ConditionllAllowable

I certify this CDRS complies with he cot{TRoL REF NO. 6500


rcquirements of the applicable ode MATERIALS
The Design Report & Design Specification are in
Plate: N/A
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-36, A-108 1018 CW (CC N-249)
NF 2007 Edition and are on file at:
Nuts: 5A-563 GrA
Pin: N/A
Bergen Power Pipe Supports,lnc,
See Sheet I Studs: N/A
Product Engineering Department
Exempt N/A
REVISIONS
/il Orioinal lssue 10/27109 /3\
A 4\
I
SEAL ISIGNED /i /t
BERGEfV POWER PIPE SUPPORTS, INC, SHEET ZOF 2 REv. a PART NO. 6500
JJ-
,rJ
*f,
CDRS CATALOG INFORMATION SHEET

-
LONG TANGETVT U.BOLT . PART NUMBER 6500

PIPE
A B c D
L

srzE
1t2 3/8 15/16 1 5t16 21t2 21t4
3t4 3/8 1118 11t2 2518 2 5t16
1 3/8 1 3/8 13t4 2314 2 5t16
11t4 3/8 13t4 21t8 3 5/8 3

1112 3/8 2 2318 3 5/8 2718


2 3/8 2 7t16 213t16 3 3t4 3

2112 112 215t16 3 7t16 3 314 3


3 1t2 3 9/16 4 1t16 4 3
3112 1t2 4 1t16 4 9t16 41t4 3 3/8
4 1t2 4 9/16 E
1t16 41t2 3 3i8
5 1t2 5 5/8 6 1/8 5 3 3/8

---1 6 s/8 6 3/4 7 3/8 6 1/8 3 3i4


I I 5/8 I 3/4 I 3/B 7 1t8 33t4
I
10 314 107t8 115t8 8 3/8 4
I
I

12 7t8 127t8 13314 5/8 41t4


tri i
14 7t8 141t8 15 10114 41t4
I

16 7t8 16 1/8 17 11 114 41t4


18 1 18118 19 1/8 12518 4 3t4
20 1 201t8 21 1t8 13 5/8 4 314
24 1 241t8 251t8 15 5/8 43t4
261t8 27 1t8 16 5/8 4314
-J 26
28
1

1 28118 291t8 17 5t8 4314


30 1 30 1/8 31 1/8 18 5/8 43t4
36 1 361/8 37 1t8 21s18 4 314

NOTES:
t.; nll dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) When using as a Guide (Condition ll), upset threads after installation per NF-4725.
4.) lVtren using U-Bolt sizes 1/2" through 1-112" as a Guide (Condition ll). A spacer, supplied by others,
is recommended between the pipe and supporting member, tack welded in place.
Spacer = 114" xll{." x 1" lg.

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size'

D(AMPLE: 6500-Rl0-5"

REVISIONS
Al0rlqinal lssue 10/27109 /)
/1\ /;
/z\ /i
BERGFN POWER PIPE SUPPORIS, INC. SHEETl OF 1 REV. A PART NO. 6500
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
tit L d
b
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS

TOTVG TANGENT U.BOLT . PART NUMBER 6502

Condition I

DIRECTION OF LOADING DIRECTION OF LOADING

I <---_---> TemPerature: 6500F


I
No"t
Fo, the test condition (Hydro) the maximum temperature is 100oF. For higher
Design Spec. No. DS-6500
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6502
shou'n for the Operating Condition.

Desisn Condition Operating Conditions Test Condition


Size (see Note)
Cond. I Cond.ll Level A Level B Level C Level D
1t2 1,340 170 1,340 170 1,780 220 2.010 250 2,680 340 1,780 220
3/,4 1,530 90 1.530 90 2,030 120 2,29A 130 3,060 180 2,030 120
1 1,360 80 1,360 80 1,800 100 2,040 120 2.720 160 1,800 100
11/i4 2,850 360 2,850 360 3,790 470 4,270 540 5.700 724 3,790 470
11//2 2,540 310 2,540 310 3,370 410 3,810 460 5,080 620 3.370 410
2 2,600 210 2,600 210 3,450 280 3,900 310 5,200 420 3,450 280
2',112 4,430 420 4,430 424 5,890 550 6,640 630 8,860 840 5,890 550
3 6,460 270 6,460 270 8,590 350 9,690 400 12,920 540 8,590 350

31i/2 4,070 260 4,070 260 5,410 340 6,100 390 8,140 520 5,410 340
4 6,710 220 6,710 220 8.920 290 10,060 330 13,420 440 8,920 290
5 6,260 210 6,260 210 8,320 270 9,390 310 12,520 420 8,320 270
6 9,130 340 9,1 30 340 12,140 450 13.690 510 18,260 680 12,140 450
Rated Loads (lbs) for Classes 1,2,3 &MC
Loads for Condition I are listed first, Condition ll are listed second.
For simultaneous loading: Condition I Load * Condition ll Load
5
Condition I Allowable Condition ll Allowable

I certify ihis CDRS complies wiih fie CONTROL REF NO, 6502
mquirements ol the applicabh oode MATERIALS
The Design Report & Design Specification are in
Plate: N/A
accordance with ASME BPVC Section lll, Subsection
U-Bolt: sA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: N/A
Bergen Power Ptpe Sup ports, lnc.
Studs: N/A
Product Engineering Department
Exempt N/A
REV|SIONS
/d, Oriqinal lssue 0/27109 /i
fu;*K,&77
1

/t
$epg \rc,ltz/of ISIGNED /i /)
BERGEN POWER PIPE SUPPORTS, INC. SHEET |OF 2 REV.
A PART NO. 6502
tit*r, b
CERTIFIED DESIGN REPORT SUMMARY
for
NUGLEAR POWER PLANT STANDARD SUPPORTS

LONG TA'VGE VT U.BOLT . PART NUMBER 6502

DIRECTION OF LOADING DIRECTION OF LOADING

-e
I Temperature: 6500F
I

nott'
Fol. the test condition (Hydro)the maximum temperature is 1000F. For higher
Design Spec. No. DS-6500
temperatures in the Test Condition, use Level B loads up to the temperature
Design Report No. DR-6502
shown for the Operating Condition.

DesiEn Condition Operating Gonditions Test Gondition


Size (see Note)
Cond. I Cond.ll Level A Level B Level C Level D
8 14,520 270 14,520 270 19,310 350 21,780 400 29,040 540 19,310 350

10 20,610 400 20,610 400 27,410 530 30,910 600 41,220 800 27,410 530
12 27j60 630 27,160 630 36,120 830 40.740 940 54,320 1,260 36,120 830
14 27.860 560 27,860 560 37,050 740 41.790 840 55,720 1,120 37,050 740
16 29,620 440 29,620 440 39,390 580 44,430 660 59,240 880 39,390 580

18 26,820 570 26,820 570 35,670 750 40,230 850 53,640 1,140 35,670 750

20 32,380 580 32.380 580 43,060 770 48,570 870 64,760 1,160 43,060 770
24 28.400 s20 28,400 520 37,770 690 42.600 780 56,800 1,040 37,770 690

26 34,090 430 34,090 430 45,340 570 51.130 640 68,180 860 45,340 570

28 34,950 400 34,950 400 46,480 530 52,420 600 69,900 800 46,480 530

30 34,690 300 34,690 300 46,130 390 52,030 450 69,380 600 46,130 390

36 26,670 340 26,670 340 35,470 450 40,000 sl0 53,340 680 35,470 450
Rated loads (lbs) for C/asses 1,2,3 & MC
Loads for Condition I are listed first, Condition ll are listed second.
For simultaneous loading: gondition I Load *
Condition ll Load
ConditionlAllounable ConditionllAllowable

I certify this CDRS complies wifi he CONTROL REF NO, 6502


requirements of the applicable code MATERIALS
The Design Report & Design Specification are in
Plate: N/A
accordance with ASME BPVC Section lll, Subsection
U-Bolt SA-193 87
NF 2007 Edition and are on file at:
Nuts: SA-194 2H
Pin: N/A
Bergen Power Pipe SuPPorts, lnc.
See Sheet 1 Studs: N/A
Product Engineering DePartment
Exempt N/A
REV|StONS
io\ Oriqinal lssue 10/27109 /3\
/1\ /i
SEALI ISIGNED /i /il

BERGEIV POWER PIPE SUPPORTS, INC, SHEET ?OF 2 REV.


A PART NO. 6502
tit d
E
,, CDRS CATALOG INFORMATION SHEET

LONG IANGENT U.BOLT . PART NUT|f/BER 6502

PIPE
A B c D E
SIZE
112 1t4 15/16 1 3/16 2112 21t4
314 1t4 11t8 1 3/8 2 5t8 23t8
1 1t4 1 3/8 1 5/8 23t4 23t8
1114 3/8 13t4 21t8 27t8 21t2
11t2 3/8 2 23t8 3 21t2
2 3/8 21t2 27t8 31t4 21t2
2112 1t2 3 31t2 3 3t4 3

3 1t2 3 5/8 41t8 4 3

3112 1t2 41t8 4 5/8 41t4 3


4 1t2 4 5t8 5 1/8 4112 3

I
5 1t2 5 5i8 6 1t8 5 3

6 5/8 6 3t4 7 3t8 61/8 33t4


I 5i8 8 3t4 9 3t8 71t8 33t4
10 314 107t8 115t8 8 3/8 4
12 7t8 127t8 13314 I 5/8 41t4
E 14 7tB 141t8 15 10114 41t4
16 7t8 16 1/8 17 111t4 41t4
18 1 18 1/8 19 1/8 12518 4 3t4
20 1 201t8 21 1t8 13 5/8 4 314
24 1 241t8 25118 15 5/8 43t4
26 I 26118 27 118 16 5/8 43t4
28 1 281t8 291t8 17 518 43t4
30 1 30 1/8 31 118 18 5/8 43t4
36 1 36 1/8 37 1t8 215t8 4 3t4

NOTES:
1.) All dimensions are in inches.
2.) Dimensions are provided for user application only.
3.) When using as a Guide (Condition ll), upset threads after installation per NF-4725.
4.)When using U-Boltsize 112" as a Guide (Condition ll). Jam nuts are required on top of the steel,
instead of full nuts, ,

ORDERING INSTRUCTIONS:
Specify: Part Number, CDRS Revision Number, and Pipe Size.

E)(AMPLE: 6502-FU0-5"

REVISIONS
/il 1Orlqinal lssue 10/27109 /t'
r\ /r\
/2' /t
BERGE,\J POWER PIPE SUPPORTS, INC. SHEET 1 0F 1 REV.
A PART NO. 6502
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
LOAD CAPACITY DATA SHEET
for
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS
U.BOLT RESTRAINT CLAMP

l
LOAD
,l'
-+*
100 (ryP) I
,\l..
-,(.

F
il !
d
b \) DIRECTION
OF
LOADING

DESIGNED BY: Load Rating TEMPERATURE:650 f


LOAD RATTNG (LBS)
for Glass 1,2,3 & MC
OPERATING CONDITIONS
DESIGN
SIZE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
.{9 -p s NORMAL UPSET EMERGENCY FAULTED CONDITION
EUJ> 1t2" 700 700 930 1 050 1 400 931
314" 700 700 930 1 050 1 400 931
1 700 700 930 1 050 1 400 931
1 114 700 700 930 1 050 1 400 931
N 1 112 700 700 930 1 050 1 400 931
? 2 700 700 930 1 050 1 400 931
I
CD

ul
J
(n
F
o
o
J
o
uJ
a
l.U
E
o
z
tr.
]U

lIJ
o
o
O
lu
F NOTE: I certify that this LCDS complies Materials:
o with the requirements of the applicable I lg-t wts rvr tralc Pr 9vr
0-
f code. )tate: sA-36 perlormed in accordance with: ASME BPVC SECTION lll,

l< )in: 5A-564 TYPE 630


SUBSECTION NF COMPONENT SUPPORTS 2OO7 EditiON
n and are on file at:
EIII> J-Bolt: 5A-36 ,/1 \
\uts: SA-307 GR B BERGEN.POWER PIPE SUPPORTS, INC.
H* Product Englneerlng DePartment
dE
(ll - Sotter pins, Washers, Retainers Exempt (NF-1110) ]ONTROLREF. NO. 6525
gb
E,
o
Il|f,
?LE
BERcEN-powER ptpE s.tppoars, tNc.
LOAD CAPACITY DATA SHEET
Sheet
_!_ol1 A
REV. PART NO
6525-0.7
R SWIN6
G
l i--
l
TORQUE

fftl-ttt loot'vp
RADIUS

---I \/ \$\'
4
ffi I
L
-I
E
+
li
Iq
t

/i7>' \

k )'
\
()
-\,-
I
-T-
6
b A

3 11/16

NOTES: 1. All dimensions are in inches.


2. Minimum sprino rate by test = 500 Kips/in.
3. This assembly to be used with Parts 2015,2250,2252 &2440.
3. Dimensions are provided for user application only.

ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 6525-.7'R 11' 1"

EERGEN-POWER PIPE SUPPORTS INC. PART 6525-0.7


CATALOG INFORMATION SHEET DATE 91112007
LOAD CAPACITY DATA SHEET
for
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS
U.BOLT RESTRAINT CLAMP

A
LOAD
;f_
lOoorpl \
i

'\.{(
-\

ft

X
('
b \: DIRECTION
OF
LOADING

ESIGNED BY: Load Rating TEMPERATURE:650 f


LOAD RATTNG (LBS)
for Glass 1,2,3 & MC
OPERATING CONDITIONS
DESIGN
srzE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
€ -s, sr NORMAL UPSET EMERGENCY FAULTED CONDITION
EIU> 112' 1 500 1 500 2000 2250 3000 1 995
314" 1 500 1 500 2000 2250 3000 1 995
1 1 500 1 500 2000 2250 3000 1 995

1 1/4 1 500 1 500 2000 2250 3000 1 995

F* 1 112 1 500 1 500 2000 2250 3000 1 995


o I

I
2 1 500 1 500 2000 2250 3000 1 995
ct)
uJ
J
m
F
o
o
J
o
lIJ
U)

lU
E
o
z
E
UJ

lrJ
o
o
O
UJ
F NOTE: I certify that this LCDS complies Materials:
o
(L with the requirements of the applicable
f code. Plate: 5A-36 perrormed in
"ccoro"n""?;fft'ffi;i"-Ji.ttot,,,,
SUBSECTION NF COMPONENT SUPPORTS 2OO7 EditiON
G Pin: 5A-564 TYPE 630 and are on llle at:
EIJI> U-Bolt: SA-36 7\
Nuts: SA-307 GR B BENGEN-POWER PIPE SUPPORTS, INC.
H*

ffi
Product Engineerlng Department
CLOUTIER
6E
A- NO. 6525
Ootter pins, Washers, Retainers Exempt (NF-1110) 3ONTROLREF.
gb ms t ART NO
tr
o HJ
BERGEN.POWER PIPE SUPPORTS, INC.
LOAD CAPACITY DATA SHEET
Sheet
1ol1 AREV.
6525-1.5

-
R 5WIN6

:I G

I
TORQUE

ffi-ttt'
\t
loornp:
\K.
RADIU5

f
P r.J(

ffi I
E
+
t' n
n
L T

7) \
/
\
/)
\ )t (/

b It l>

3 13/16

3 15/16

NOTES: 1. All dimensions are in inches.


2. Minimum soring rate by test = 500 Kips/in.
3. This assembly to be used with Parts 2015,2250,2252 & 2440.
3. Dimensions are provided for user application only.

ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 6525-.1 .5-R/1- 1"

BER6EN.POWER PIPE SUPPORTS INC. PART 6525-1 .5


CATALOG INFORMATION SHEET DATE 91112007
LOAD CAPACITY DATA SHEET
lor
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS

-tr
B
R
E

b
I
\.,
I
DIRECTION
OF
LOADING

SIGNED BY: Load Rating TEMPERATURE:650 f


LOAD RATTNG (LBS)
for Class 1,2,3 & MC
OPERATING CONDITIONS
DESIGN
SIZE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
G al 'ltz"
NORMAL UPSET EMERGENCY FAULTED CONDITION
EUJ> 700 700 930 1 050 1400 931
314" 700 700 930 1 050 1400 931
1 700 700 930 1 050 1400 931
1 114 700 700 930 1 050 1400 931
l- 1 112 700 700 930 1 050 1 400 931
o
700 930 1 050 1 400 931
I

I
2 700
CD

lrJ
J
dt
F
o
o
J
o
lu
I
lIJ
tr
o
z
E
UJ

IU
o
o
O
]u
F NOTE: I certify that this LCDS complies Materials:
o with the requirements of the applicable
tL
f code. Plate: 5A-36 perrormed tn accordancffiffiti* tif.Ti"tto",t,,
SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon
Pin: 5A-564 TYPE 630 n and are on fite at:
EIJI> U-Bolt: 5A-36 ,/1 \
Nuts: SA-307 GR B BERGEN.POWER PIPE SUPPORTS, INC.
IJJ Cr) Product Engineering DePartment
f@
aa
U'< o, Cotter pins, Washers, Retainers Exempt (NF-1110) OONTROLREF. NO. 6525
gS BERcEN-powER ptpE suPPoRTs, tNc. ,ART NO
E,
o
IH;
:1 LoAD cAPActrY DATA sHEET
Sheet
-!ot 1
REV.
,/\ 6526-0.7
R 5WIN6
RADIU5
lOotrvp> i- {-
- TORQUE
/'.\ 15 FT-LBS.
!4

I
(T/P)
^1
i 1 -'-\
{ \l-/,
\\\; /////
,

3 11/16

NOTES: 1. All dimensions are in inches.


2. Minimum sprinq rate bv test = 500 Kips/in.
3. This assembly to be used with Parts2015, 2250,2252 &2440.
3. Dimensions are provided for user application only.

ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 6526-.7-R 11- 1"

BERGEN.POWER PIPE SUPPORTS INC. PART 6526-0.7


CATALOG INFORMATION SHEET DATE 9t112007
LOAD CAPACITY DATA SHEET
lor
NUCLEAR POWER PLANT COMPONENT STANDARD SUPPORTS

,l
LOAD
V

-fr

tR
5
,/ 1 ..\
/t

\
i--T-,
b
I

(
I
DIRECTION
"-2 OF
LOADING

SIGNED BY: Load Rating TEMPERATURE:650 T


LOAD RATTNG (LBS)
for Class 1,2,3 & MC
OPERATING CONDITIONS
DESIGN
stzE LEVEL A LEVEL B LEVEL C LEVEL D TEST
CONDITION
6 NORMAL UPSET EMERGENCY FAULTED CONDITION
EUJ> 1tz" 1 500 150t) 2000 2250 3000 1 995
314" 1 500 1 500 2000 2250 3000 1 995
1 1 500 1 500 2000 2250 3000 1 995

1 114 1 500 1 500 2000 2250 3000 1 995

F- 1 112 1 500 1 500 2000 2250 3000 1 995


o t

I
2 1 500 1 500 2000 2250 3000 1 995
CD

IIJ
J
d)
F
o
o
J
o
IJJ
9,
]JJ
E
o
z
E
lrJ

]U
o
o
O
Lu
F NOTE: I certify that this LCDS complies Materials:
o with the requirements of the applicable Stress calculations or tesl data for this product were
L
l code. )late: 5A-36 perlormed ln accordance with: ASME BPVC SECTION lll,
)in: S4-564 TYPE 630
SUBSECTION NF COMPONENT SUPPORTS 2007 Editlon
n and are on lile at:
EIJJ> J-Bolt: SA-36 ,/1\
\uts: SA-307 GR B BERGEN.POWER PIPE SUPPORTS, INC.
IJJ Cr) Product Engineerlng Department
f@
aa
(r) <
O) Sotter pins, Washers, Retainers Exempl(l',1!- l!_lQ) sONTROLREF. NO. 6525
ES
E,
o
BERGEN-POWER PIPE SUPPORTS, INC.
LOAD CAPACITY DATA SHEET
Sheet
1of 1
AREV.
'ART NO
6526-1.5
R 5WIN6
RADIUS
lQot"yp> l l .
/'&\ wj(

I
---\
/ 1,
{ \l-/,
\\\; --l///
,

3 13/16

3 15/16

NOTES: 1. All dimensions are in inches.


2. Minimum sprino rate bv test = 500 Kips/in.
3. This assembly to be used with Parts2015,2250,2252 &2440.
3. Dimensions are provided for user application only.

ORDERING INSTRUCTIONS: Specify Part No.; LCDS Rev. No. & Size Designation.

EXAMPLE: 6526-1.5-R/1- 1"

TERGEN-POWER PIPE SUPPOBTS INC. PART 6526-1 .5


CATALOG INFORMATION SHEET DATE 9t112007
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
U.BOLT CRADLE GUIDE

DIRECTION
OF
LOADING

Temperature-: 600'F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8460 R0


DESIGN REPORT NO.: DR-8460 R0
F lE' v Rated Loads (lbs) for Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS
PIPE SIZE
Condition Level A Level B Level C Level D Test Condltion (see Note)

2 10000 10000 13300 15000 20000 13300


2112 10000 10000 13300 15000 20000 13300
3 10000 10000 13300 15000 20000 13300
4 10000 10000 13300 15000 20000 13300
5 15000 15000 19950 22500 30000 19950
6 15000 15000 19950 22500 30000 19950
8 15000 15000 19950 22500 30000 19950
10 15000 15000 19950 22500 30000 19950
12 15000 15000 19950 22500 30000 19950
14 20000 20000 26600 30000 40000 26600
16 20000 20000 26600 30000 40000 26600
18 20000 20000 26600 30000 40000 26600
20 25000 25000 33250 37500 50000 33250
24 25000 25000 33250 37500 50000 33250

rcenrymrs uuHD
"otp@
equirements ol the applicable Code. I

Materials: The Design Report & Design Specification


t\
o Plate:54-36 are in accordance with ASME BPVC Section lll,
Q Subsection NF, 2007 Edition and are on file at:
O) Round Bar::5A-36
lLl
f Nuts:54-563 GR A
a
a Bergen Power Pipe Supports, Inc.
J
Producl Engineerlng Department
z
o Slide Bearings Exempt (NF-11 10)
E ]ONTROL REF NO. 8460
o
PAfI I N(,.
a Sheet REV.

REV Certification
=.RGEN-POWER PIPE SUPPORTS, 1of 3 ,/d\ 8460
''V
ms
H Hd
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
U.BOLT CRADLE GUIDE

+-

DIRECTION
OF
LOADING

Temperature:_.@9--T_

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8460 R0


7 7 DESIGN REPORT NO.: DR-8460 R0
rp -t
REV Rated Loads (lbs) for Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS
PIPE SIZE
Condition Level A Level B Level C Level D Test Condition (see Note)
2 500 500 665 750 1000 665
21t2 500 500 665 750 1000 665
3 500 500 665 750 1000 665
4 500 500 665 750 1000 665
5 1500 1500 1995 2250 3000 1995
6 1500 1500 1995 2250 3000 1995
I 2000 1500 1995 2250 3000 1995
10 2000 2000 2660 3000 4000 2660
12 2000 2000 2660 3000 4000 2660
14 4000 4000 5320 6000 8000 5320
16 4000 4000 5320 6000 8000 5320
18 4000 4000 5320 6000 8000 5320
20 5000 5000 6650 7500 10000 6650
24 5000 5000 6650 7500 10000 6650

cenrry mrs oDRS


r
"otpffiTil
equirements of the applicable Code. I

Materials: The Design Report & Design Specification


N
o Plate:5A-36 are in accordance with ASME BPVC Section lll,
o
o, Round Bar::5A-36 Subsection NF, 2007 Edition and are on file at:
TU
f, Nuts:5A-563 GR A
o
a Bergen Power Pipe Supports, lnc.
J
Product Engineering Department
1
Itr Slide Bearings Exempt (NF-11 10)
o SONTROL REF NO. 8460
PART NO.
Sheet

REV Certilication
=.RGEN.POWEB PIPE SUPPORTS, 2of3 ,/d\ 8460
''V
t-

CERTIFIED DESIGN REPORT SUMMARY


for
NUCLEAR POWER PLANT STANDARD SUPPORTS
U.BOLT CRADLE GUIDE

DIRECTION
OF
LOADING

Temperature: 600 " F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8460 R0


S DESIGN REPORT NO.: DR-8460 R0
IE V Rated Loads (lbs) lor Classes '|.,2,3 MC
FL Design OPERATING CONDITIONS
PIPE SIZE
Condition Level A Level B Level C Level D Test Condition (see Note)
2 250 250 333 375 500 333
2 1t2 250 250 333 375 500 333
3 250 250 333 375 500 333
4 250 250 333 375 500 333
5 500 500 665 750 1000 665
6 500 500 665 750 1000 665
I 500 1500 1995 2250 3000 1995
10 1000 1000 1330 1500 2000 1330
12 1000 1000 1330 1500 2000 1330
14 2000 2000 2660 3000 4000 2660
16 2000 2000 2660 3000 4000 2660
18 2000 2000 2660 3000 4000 2660
20 2500 2500 3325 3750 5000 3325
24 2500 2500 3325 3750 5000 3325

I certify this CDRS .otpli"t with the


I
'equirements ol the applicable Code.
I
Materials: The Design Report & Design Specification
t\
o Plate:5A-36 are in accordance with ASME BPVC Section lll,
o
o, Round Bar::54-36 Subsection NF, 2007 Edition and are on file at:
r.u
f, Nuts:3A-563 GR A
a
a Bergen Power Pipe Supports, Inc.
J
Product Engineering Department
z
g Slide Bearings Exempt (NF-11 10)
tr CONTROL REF NO. 8460
PAHT NO.
Sheet
:RGEN.POWER PIPE SUPPORTS, IN 3of3 i6'( 8460
REV Certification
U.BOLT CRADLE GUIDE

rrArr
I i* -r i
r--tr-ltFil

- -
116,
!-

PIPE STZ;E A c D E L
2 4 7 1t4 4 5 5 3/16
21t2 4 7 1t4 5 5 5 7t16
\lr, \s { 3 4 7 1t4 5 1t2 5 5 3t4
REV
4 4 7 1t4 61t2 5 6114
5 4 7 1t4 7 5t8 5 6 13/16
6 4 7 1t4 91/8 5 7 5/16
I 4 7 1t4 11 1t4 5 I 5/16
10 4 7 1t4 14 5 I 3/8
12 4 7 1t4 16 3t4 5 10 3/8
14 4 7 1t4 18 5 11
16 4 7 1t4 19 3t4 5 12
18 7 10 3t4 22 5112 13
20 7 10 3t4 24 5112 14
24 7 10 3t4 28 5 1t2 16

NOTES: 1 . All dimensions are in inches.


F-
2. Dimensions are provided for user application onlv.
o
o
F

o) ORDERING INSTRUCTIONS:
[U
f
CD
a Specify Part No.; CDRS Rev. No. & Size Designation.
J
z
g EXAMPLE: 9460-R/0- 6"
E
o
G (o
REV

rFls BERGEN-POWER PIPE SUPPORTS PART 8460


Hd
H CDRS CATALOG INFORMATION SHEET DATE 91112007
m;
Hd
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
UN]SLIDE CLAMP CRADLE SLIDE WITH BONDED SLIDE PLATE

DIRECTION
OF
LOADING

Temperature: 350F

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8520 RO


DESIGN REPORT NO.: DR-8520 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MC
Design OPERATING CONDITIONS
PIPE SIZE Test Condition
Condition Level A Level B Level C Level D (see Note)

2 10000 10000 13300 15000 20000 13300


2 112 10000 10000 13300 15000 20000 13300
3 10000 10000 13300 15000 20000 13300
4 10000 10000 13300 15000 20000 13300
5 15000 15000 19950 22500 30000 19950
6 15000 15000 19950 22500 30000 19950
I 15000 15000 19950 22500 30000 19950
10 15000 15000 19950 22500 30000 19950
12 15000 15000 19950 22500 30000 19950
14 20000 20000 26600 30000 40000 26600
16 20000 20000 26600 30000 40000 26600
18 20000 20000 26600 30000 40000 26600
20 20000 20000 26600 30000 40000 26600
24 20000 20000 26600 30000 40000 26600

I certify this CDRS complies with the


I
'equirements of the applicable Code. I

Materials: The Design Report & Design Specification


r\
o Plate: 5A-36 are in accordance with ASME Section lll,
o
b Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at:
uJ EUGENE
f R. \uts:5A-563 GR A
@
a CLOUTIER Studs:SA-36 Bergen Power Pipe Supports, lnc.
J
Product Englneerin g Department
z
CI Exempt (NF-l110) Graphite Slide, Cotter Pins,
(r
o Washers, Retainers OONTROLREFNO. 8520
PABT NO.
Sheet
BERGEN-POWER PIPE SUPPORTS, INC. 8520
REV Certification l-of 1

^\
UNISLIDE CLAMP CRADLE SLIDE WITH BONDED SLIDE PLATE WELD ryPE
ilDil +

! "e" -]
a
-12
PIPE
STZ:E A c D E L
2" 4" 12" 5 3/8" 5" 5 3/16"
2 t/?" 4" 72" 6 t/?" 5r' 5 7 /16"
\lo {ir \(t)
3rt 4" 12" 7" 5" 5 3/4"
lEV
4" 4" t?" 8 3/4" 5" 6 t/4"
5r' 4" t?" g7/9" 5" 6 3/4"
6" 4" t?" tl 3/4" 5" 7 5/t6"
gt' 4" l?" 14" 5r' g 5/16"
10" 4" t2" 77 t/8" 5r' g 5/16"
12" 4" 12" 19 t/8', 5r' 70 3/9"
14" 4" t2" ?7 t/4', 5" 11"

16" 4" t?" 23 l/4" 5rt 12"

19" 7" 15" ?6" 5 t/?" 13"

20" 7" 15" 2g l/4" 5 7/?" 14"

N 24" 7" 15" 33 3/4', 5 1/?" t6"


o
o NOTES: 1 dimensions are in inches.
. All
O)
TIJ
l 2. Dimensions are provided for user application onlv.
a
a
J
ORDERING INSTRUCTIONS: Specify Part No.; CDRS Rev. No. & Size Designation.
z
g
(r
o EXAMPLE: 8520-R/0- 6"
G \o
lEV

TFA BERGEN-POWER PIPE SUPPORTS PART 8520


Hi
H CDRS CATALOG INFORMATION SHEET DATE 9t1t2007
m;
HMd
CERTIFIED DESIGN REPORT SUMMARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
CLAMP CRADLE GUIDE

DIRECTION
OF
LOADING

Temperature-1Q@f

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8560 R0


E)
2
q DESIGN REPORT NO.: DR-8560 RO
REV Rated Loads (lbs) for Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS
PIPE SIZE Test Condition
Gondition Level A Level B Level C Level D (see Note)

2 10000 10000 13300 15000 20000 13300


2 112 10000 10000 13300 15000 20000 13300
3 10000 10000 13300 15000 20000 13300
4 10000 10000 13300 15000 20000 13300
5 15000 15000 19950 22500 30000 19950
6 15000 15000 19950 22500 30000 19950
I 15000 15000 19950 22500 30000 19950
10 15000 15000 19950 22500 30000 19950
12 15000 15000 19950 22500 30000 19950
14 20000 20000 26600 30000 40000 26600
16 20000 20000 26600 30000 40000 26600
18 20000 20000 26600 30000 40000 26600
20 25000 25000 33250 37500 50000 33250
24 25000 25000 33250 37500 50000 33250

requirements of the applicable Code. I

Materials: The Design Report & Design Specification


Ir
o Plate:5A-36 are in accordance with ASME BPVC Section lll,
o
ct) Round Bar::54-36 Subsection NF, 2007 Edition and are on file at:
Lu
f \uts:5A-563 GR A
C)
a Bergen Power Pipe Supports, lnc.
J
Product Engineerlng DePartment
z
o Slide Bearings Exempt (NF-1 1 10)
E SONTROL REF NO. 8560
o
PART NO.
Sheet REV.
EKF BERGEN-POWER PIPE SUPPORTS, INC.
REV Cerlilication l_of 3 8560
^\
nfr
Hf,
H
CERTIFIED DESIGN REPORT SUMM ARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
CLAMP CRADLE GUIDE

DIRECTION
OF
LOADING

Temperature: 600 'F


NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8560 R0


4 DESIGN REPORT NO.: DR-8560 RO
REV Rated Loads (lbs) for Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS Test Condition
PIPE SIZE (see Note)
Condition Level A Level B Level C Level D
2 500 500 665 750 1000 665
2 1t2 500 500 665 750 1000 665
3 500 500 665 750 1000 665
4 500 500 665 750 1000 665
5 1500 1500 1995 2250 3000 1995
6 1500 1500 1995 2250 3000 1995
I 2000 1500 1995 2250 3000 1995
10 2000 2000 2660 3000 4000 2660
12 2000 2000 2660 3000 4000 2660
14 4000 4000 5320 6000 8000 5320
16 4000 4000 5320 6000 8000 5320

18 4000 4000 5320 6000 8000 5320


20 5000 5000 6650 7500 10000 6650
24 5000 5000 6650 7500 10000 6650

equirements of the applicable Code. I


Materials: The Design Report & Design Specification
t-
o Plate:5A-36 are in accordance with ASME BPVC Section lll,
o
o, Round Bar::54-36 Subsection NF, 2007 Edition and are on file at:
IU
l Nuts:5A-563 GR A
a
9. Bergen Power Pipe Supports, lnc.
J
Producl Engineering Department
z
g Slide Bearings Exempt (NF-1 1 10)
(r NO. 8560
o CONTROL REF

K
PART NO.
Sheet
BERGEN.POWER PIPE SUPPORTS, INC. 2ot 3 8560
REV Certitication
CERTIFIED DESIGN REPORT SUMMARY

r7l;
Hd
U
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
CLAMP CRADLE GUIDE

DIRECTION
OF
LOADING

Temperature: 600 'F


Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8560 R0


DESIGN REPORT NO.: DR-8560 RO
REV Rated Loads for Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS Test Gondition
PIPE SIZE
Gondition Level A Level B Level C Level D (see Note)
2 250 250 333 375 500 333
2 1t2 250 250 333 375 500 333
3 250 250 333 375 500 333
4 250 250 333 375 500 333
5 500 500 665 750 1000 665
6 500 500 665 750 1000 665
I 500 1500 1995 2250 3000 1995
10 1000 1000 1330 1500 2000 1330
12 1000 1000 1330 1500 2000 1330
14 2000 2000 2660 3000 4000 2660
16 2000 2000 2660 3000 4000 2660
18 2000 2000 2660 3000 4000 2660
20 2500 2500 3325 3750 5000 3325
24 2500 2500 3325 3750 5000 3325

rcenrry mrs uuFrD


"otp@
equirements of the applicable Code. I

Materials: The Design Report & Design Specification


t\
Q
F Plate:54-36 are in accordance with ASME BPVC Section lll,
o
b Round Bar::54-36 Subsection NF, 2007 Edition and are on file at:
lU
l \uts:5A-563 GR A
a
a Bergen Power Pipe Supports, lnc.
- Product Engineering Department
z
o Slide Bearings Exempt (NF-11 10)
E sONTROL REF NO. 8560
IO
7 PAt{ r N(,.
(\
REV Certification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

lof 3 K 8560
CLAMP CRADLE GUIDE

PIPE 5,TZE A c D E L
2 4 7 1t4 5 1t2 5 5 3t16
2 1t2 4 7 1t4 6 5 5 7t16
6 3 4 71t4 7 1t4 5 5 314
lEV 4 4 7 1t4 8 114 5 6114
5 4 7 114 I 1t4 5 6 13/16
6 4 7 1t4 11 1t2 5 7 5/16
8 4 7 1t4 13 1t2 5 8 5/16
10 4 7 1t4 14 5 9 3/8
12 4 7 1t4 19 1t4 5 10 3/8
14 4 7 1t4 21 5 11
16 4 7 1t4 23 5 12
18 7 10 3t4 25 5 112 13
20 7 10 3t4 27 5112 14
24 7 10 3t4 31 1t2 51t2 16

NOTES: 1 . All dimensions are in inches.


l-
2. Dimensions are provided for user application onlv.
o
o
o) ORDERING INSTRUCTIONS :
tU
l
U)
a Specify Part No.; CDRS Rev. No. & Size Designation.
J
z
(, EXAMPLE: 8560-R/0- 6"
E
o
G (o
1EV

m
E
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE 91112007
8560
m;
Nd
fl
CER\IFIED DES\GN REPORT SUtltiltARY
lor
NUCLEAR POWER PLANT STANDARD SUPPORTS
GRAPHITE SLIDE PLATE WELDED TYPE

DIRECTION
OF
LOADING

Temperature:ff
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8820 R0


6 4 DESIGN REPORT NO.: DR-8820 RO
REV Rated Loads (lbs) lor Classes 1,2,3 & MC
Design OPERATING CONDITIONS Test Condition
stzE
Condition Level A Level B Level C Level D (see Note)
1 40000 40000 53200 60000 80000 53200
2 56000 56000 74480 84000 11 2000 74480
3 88000 88000 117040 132000 1 76000 117040
4 136000 1 36000 1 80880 204000 272000 1 80880
5 184000 1 84000 244720 276000 368000 244720
6 232000 232000 308560 348000 464000 308560
7 280000 280000 372400 420000 560000 372400
8 328000 328000 436240 492000 656000 436240
I 376000 376000 500080 564000 752000 500080
10 472000 472000 627760 708000 944000 627760
11 568000 568000 755440 852000 1 1 36000 755440
12 1 26000 1 26000 1 67580 1 89000 252000 1 67580

13 1 53000 1 53000 203490 229500 306000 203490


14 80000
1 1 80000 239400 270000 360000 239400
15 207000 207000 275310 31 0500 41 4000 275310
16 243000 243000 3231 90 364500 486000 3231 90
17 261 000 261 000 347130 391 500 522000 347',130
18 324000 324000 430920 486000 648000 430920

-"
equirements of the applicable Code. I
Materials: The Design Report & Design Specification
r\
o Plate: 5A-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at
b Slide Bearino: Graphite
IU
l
o
a Bergen Power Pipe Supports, lnc.
J
Product Englneering DePartment
o
=
tr CONTROL REF NO. 8820
o Slide Bearinq Exempt (NF-1 1 10)
PART NO.

REV Certification
BERGEN.POWER PIPE SUPPORTS, INC.
Sheet

lof 1 A 8820
GRAPHITE SLIDE PLATE WELDED TYPE

l/2" t/2" t/ 2"


!
I
ilFil
f, t
><
l

Tr4" ffi
l

il
T
uc'
3/8"

t6"5"
8" 7"

4 19"

6 6 36" 35"
IEV 42" 41"
9 48" 47" 4"
59" 4"
71" 4"
t2 15" t4" 5 t/2" 4 7/2"
13
5 t/2" 4 t/?"
5 7/?" 4 t/2"
t6 ?8" 27" 5 l/2" 4 t/2"
t7 30" 29" 5 t/2" 4 t/2"
5 t/2" 4 t/?"

f.r
o NOTES: 1. All dimensions are in inches.
o
o, 2. Dimensions are provided for user application onlv.
lrJ
f
U)
U) ORDERING INSTRUCTIONS:
J
z
g Specify Part No.; CDRS Rev. No. & Size Designation.
E
o
G EXAMPLE: 8820-R/0- 6"
REV

r77n
BERGEN-POWER PIPE SUPPORTS PART 8820
Hd
fl CDRS CATALOG INFORMATION SHEET DATE 91112007
m
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
Pre-lnsulated Ptpe Slide

)
\r' O
Et-

DIRECTION
OF
LOADING

Temperature: 650 o F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS.8821 RO


e DESIGN REPORT NO.: DR.8821 RO
REV Rated Loads (lbs) for Classes ,2,3 & MC
Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)

314" 380 380 505 570 760 505


1" 490 490 652 735 980 652
1114" 600 600 798 900 1200 798
11t2" 700 700 931 1050 1400 931
2" 810 810 1077 1215 1620 1077
3tt 1140 1 140 1516 1710 2280 1516
4" 1810 1810 2407 2715 3620 2407
5rt 2260 2260 3006 3390 4520 3006
6rt 2750 2750 3658 4125 5500 3658

rcenrry tnrs CDRS *tp,


equirements of the applicable Code. I
@ Materials: The Design Report & Design Specification
o
(o
C\I
Plate: 5A-36 are in accordance with ASME BPVC Section lll
AI
o Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
IU
lnsulation HD Calcium Silicate

ffi
:)
U)
a Nuts: 54-563 GR A Bergen Power PiPe SuPPorts,lnc.
J
z Studs: 54-36 Product Engineering DePartment

E Outer Clamp 54-36


t
o Slide Plates Exempt (NF-1 1 10) CONTROL REF NO. 8821
PART NO.

REV Certification
BERGEN.POWER PIPE SUPPORTS, INC. l
Sheet
of 1 AREV.
8821
Pre-lnsulated Pipe Slide

i/i
t/i,
,,. (:
:/,rz I
,r' ')

i
l

['-r" -]
I

-f

\lr) \(r)

lEV
1'' THK INSUL. 2'' THK INSUL. 3'' THK INSUL.
PIPE
SIZE
B c E L B c E L B c E L

314" 4" 1 112" 4 7 t16" 6" 4tt 2112" 6 1/8" 6"


1rt 4" 2" 4 11/16" 6" 4" 3rt 6 5/16" 6"
N/A
1 1t4" 4" 2" 5 1/1 6" 6" 4" 3" 611/16" 6rt
1 1t2" 4" 2" 5114'' 6" 4" 4" 6 3t4" 6"
2" 4" 21t2" 57t8" clrr 4" 4" 7 3t8" g" 6tt 5 112" I 1/1 6" g,
21t2" 4t' 21t2 6 3/8" g" 4" 4 1t2" 7 15116" g" 6" 5112" 9 9/16" gt'
3" 4" 3" 6 13/1 6" cltr 4" 4 112" 8 7 t16" clrr 6tt 5 1t2', 10 3/16" g"
4" 4" 4tt I 3/16" 12" 4" 5rt 9 13/16" 12" 6tt 6" 11 1t2" 12"
5" 4" 4112" 9 1/16 12" 4" 5" 0 1 1/16 12" 6tt g" 12318" 12"
6" 4" 5112" 9 15/16" 12" 4" 7 112" 1 1 9/16" 12" 6" g" 13114" 12"

NOTES: 1. All dimensions are in inches.


@
o 2. Dimensions are provided for user application only.
@
ol
(\I
uJ
l ORDERING INSTRUCTIONS:
U)
I Specify Part No.; CDRS Rev. No. & Size Designation and lnsulation Thickness.
J
z
o
E 8821-3"X2"-R/0
o EXAMPLE:
sr (o
]EV

ffi
U
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE 2t26t2008
8821
CERTIFIED DESIGN REPORT SUMMARY

Hd
TFli- for
NUCLEAR POWER PLANT STANDARD SUPPORTS
H Pre-lnsulated Pipe Slide

lFd
v,,/;
'lrJ;2

i/ii
iil2
DIRECTION
OF
LOADING

Temperature:.Qflf

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8821 R0


ra DESIGN REPORT NO.: DR-8821 R0
REV Rated Loads (lbs) for Glasses 1,2,3 & MC
Design OPERATING CONDITIONS Test Gondition
PIPE SIZE
Condition Fd Level A Level B Level C Level D (see Note)
314" 380 380 505 570 760 505
1tt 490 490 652 735 980 652
1114" 600 600 798 900 1200 798
1112" 700 700 931 1050 1400 931
2" 810 810 1077 1215 1620 1077
3rt 1 140 1140 1516 1710 2280 1516
4" 1810 1810 2407 2715 3620 2407
c 2260 2260 3006 3390 4520 3006
6" 2750 2750 3658 4125 5500 3658

NOTE: For simultaneous loading fd+fl


Fd allowable Fl allowable

I certify this CDRS complies with the I


requirements ol the applicable Code. I

@ Materials: The Design Report & Design Specification


o
(o
C! Plate: SA-36 are in accordance with ASME BPVC Section lll,
N
o Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
tIJ
f
a
lnsulation HD Calcium Silicate
L
J
Nuts: 5A-563 GR A Bergen Power Pipe Supports, lnc.
z Studs: 5A-36 Product Engineerlng DePartment
g Cuter Clamp 5A-36
tr Slide Plates Exempt (NF-1 1 10) CONTROL REF NO. 8822
o
PART NO.
Sheet
BERGEN.POWER PIPE SUPPORTS, INC. 1of 3 /N 8822
REV Certification
rn;
HH*
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
Pre-lnsulated Pipe Slide

-FU

DIRECTION
OF
LOADING

Temperature: 650 " F

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8821 R0


DESIGN REPORT NO.: DR-8821 R0
REV Rated Loads (lbs) for Classes 1,2,3 & MC
uesrgn OPERATING CONDITIONS Test Gondition
PIPE SIZE
Gondition Fu Level A Level B Level G Level D (see Note)
3t4 380 380 505 570 760 505
1rt 490 490 652 735 980 652
11t4" 600 600 798 900 1200 798
11t2" 700 700 931 1050 1400 931
2" 810 810 1077 1215 1620 1077
3rt 1 140 1 140 1516 1710 2280 1516
4" 1810 1810 2407 2715 3620 2407
5rt 2260 2260 3006 3390 4520 3006
6rt 2750 2750 3658 4125 5500 3658

NOTE: For simultaneous loading fu+fl


Fu allowable Fl allowable

lcertity this CDRS .otpti". with the I


requirements ol the applicable Code. I

@ Materials: The Design Report & Design Specification


O
b
ot Plate: SA-36 are in accordance with ASME BPVC Section lll,
N
o Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
lll
f
a
lnsulation HD Calcium Silicate
a Nuts: SA-563 GR A Bergen Power Pipe Supports, Inc.
J

z Studs: 5A-36 Product Englneerlng Departmenl


It Outer Clamp 5A-36
o Slide Plates Exempt (NF-1 1 10) CONTROLREFNO. 8822
PART NO,

REV Certification
BERGEN.POWER PIPE SUPPONTS, INC.
Sheet
2ol3 A 8822
m;
Hd
H
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
Pre-lnsulated Pipe Slide

Fl #-----) Fl

v'r't'< z'i
,, /4
/l
tr4
i/t
/i2 DIRECTION
OF
LOADING

Temperature:.lQ!0 'f
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8821 R0


7
{ DESIGN REPORT NO.: DR-8821 R0
F lE' 7 Rated Loads (lbs) for Classes 1,2,3 & MC
ueslgn OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Fl Level A Level B Level G Level D (see Note)
3t4" 380 380 505 570 760 505
1" 490 490 652 735 980 652
1114" 600 600 798 900 1200 798
1112" 700 700 931 1050 1400 931
2" 810 810 1077 1215 1620 1077
3" 1 140 1 140 1516 1710 2280 1516
4" 1810 1810 2407 2715 3620 2407
5rt 2260 2260 3006 3390 4520 3006
6" 2750 2750 3658 4125 5500 3658

I certify this CDRS compties wnn tne


I
'equirements of the applicable Code. I

@ Materials: The Design Report & Design Specification


o
(o
Plate: sA-36 are in accordance with ASME BPVC Section lll,
E
C\I
o Bolts: SA-307 GR B Subsection NF, 2007 Edition and are on file at
IU
f, lnsulation HD Calcium Silicate
U)
I
J
Nuts: 5A-563 GR A Bergen Power Pipe SupPorts, lnc.
z Studs: 5A-36 Product Engineerlng DePartment
(5 Cuter Clamp 5A-36
(r CONTROLREFNO. 8822
o Slide Plates Exempt (NF-1110)
PART NO.
She€t
BERGEN-POWER PIPE SUPPORTS, INC. 3_of 3 /N 8822
REV
nsulated Pipe Guide

T
r>' g
TT -fr
t7 L-
-J

1'' THK INSUL. 2'' THK INSUL.

411116"
6 11/16"

10 1 1/1 6"
13114"

NOTES: 1 dimensions are in inches.


. All
2. Dimensions are provided for user application only.
3. For full penetration weld specify optional beveled ends.
@
o
(o
c\I
c!
uJ
:)
U)
I OR DERING INSTRUCTIONS:
J
z Specify Part No.; CDRS Rev. No. & Size Designation, lnsulation Thickness
g and Beveled Ends if required.
(r
o
EXAMPLE: 8822-3"X2"-R/0

BERGEN-POWER PIPE SUPPORTS PART 8822


CDRS CATALOG INFORMATION SHEET DATE 2t26t2008
nsulated Pipe Guide

fi"cun.

\
A
T-

A +l/16"AHOLES
BY CUsT.

1t'
MAX.

NOTES: 1 . All dimensions are in inches.


2. Dimensions are provided for user application only.
@
o
(o
N
c\l
I.U
l
U)
I ORDERING INSTRUCTIONS:
J
z Specify Part No.; CDRS Rev. No. & Size Designation, lnsulation Thickness.
g
IL
o
EXAMPLE: 8823-3"X2"-R/0

BERGEN.POWER PIPE SUPPORTS PART 8823


CDRS CATALOG INFORMATION SHEET DATE 2t2612008
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
CERTIFIED DESIGN REPORT SUMMARY

g
TT7;
Hd
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
GRAPHITE SLIDE PLATE BOLTED TYPE

DIRECTION
OF
LOADING

Temperature:ff
NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition'

DESIGN SPEC NO.: DS-8840 R0


7 DESIGN REPORT NO.: DR-8840 R0
K
REV Rated Loads (lbs) for classes 1,2,3 & Mc
Design OPERATING CONDITIONS Test Condition
SIZE
Condition Level A Level B Level C Level D (see Note)
1 48000 48000 63840 72000 96000 63840
2 64000 64000 851 20 96000 1 28000 851 20
3 96000 96000 127680 144000 1 92000 127680
4 1 20000 1 20000 1 59600 1 80000 240000 1 59600
5 1 44000 144000 1 91 520 21 6000 288000 1 91 520
6 1 92000 1 92000 255360 288000 384000 255360
7 240000 240000 31 9200 360000 480000 31 9200
I 288000 288000 383040 432000 576000 383040
9 336000 336000 446880 504000 672000 446880
10 432000 432000 574560 648000 864000 574560
11 528000 528000 702240 792000 1 056000 702240
12 1 35000 1 35000 1 79550 202500 270000 1 79550

13 1 62000 1 62000 215460 243000 324000 215460


14 189000 1 89000 251370 283500 378000 251370
15 21 6000 21 6000 287280 324000 432000 287280
16 234000 234000 311220 351 000 468000 311220
17 270000 270000 3591 00 405000 540000 3591 00
18 288000 288000 383040 432000 576000 383040

-"
'equirements of the applicable Code. I
Materials: The Design Report & Design Specification
t-
o Plate:34-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at
o, Slide Bearino: Graphite
ul
f
U)
L Bergen Power Pipe Supports, lnc.
J
Product Englneering Deparlment
z
o
tr Slide Bearino Exempt (NF-1 10) 3ONTROLREFNO. 8840
o 1
PAHI N(,.

REV Certification
BERGEN.POWER PIPE SUPPOBTS, INC.
Sheet

l_of 1 AREV.

8840
GRAPHITE SLIDE PLATE WELDED TYPE
,'H" HOLE
!- 3" -l
ryP.
n
A..

l/4"
ilF..

I
__ ilBil
3/9" l---- rrErr

t 6" 10" t?" 5" 4"


?l g" 12" t4" 5" 4"
3, tzu 16" 1g" 5" 4"
4 15" 19' 21" 5rt 4" 1" t3/t6"
5 i 18" i 22" ?4" 5" 4" 1" t3/16"
6 24" 28" 30" 5" 4u 1r' t3/16"
\ro \(f) 7 30" 34" 36" 5" 4" 1" 73/t6',
lEV 8 36" 40" 4?" 5" 4" 1" t3/t6"
9 42" 46" 49" 5" 4" 1" t3/t6"
10 54" 59" 60" , 5" 4" 1tt 13/16"
n 66" 70" 72" 5rt 4" lrt 13/16"
t2 15" tg l/2" 2t" : 5 l/2" 4 t/2" t t/4' 15/t6"
13 19" 2t l/2" 24" 5 l/2" 4 t/2" t t/4' t5/16"
t4 21" ?4 t/z', ?7" " 5 t/?u 4 t/2" t 1/4" t5/16"
t5 24" 27 l/2" 30" "i 5 l/2" 4 t/z', t l/4" t t/8'
t6 26u 29 t/?" 32" 5 l/z', 4 7/2" t l/4" t t/9"
t7 30" 33 l/2" 36" 5 t/?' 4 t/zu 7 t/4', I t/9"
18
" 32', 35t/2" 38" 5 t/?' 4 l/2" tl/4" tt/8"
"
f-
o NOTES: 1 . All dimensions are in inches.
o
F

o, 2. Dimensions are provided for user application onlv.


r.rJ
f
U)
I ORDERING INSTRUCTIONS:
J
z
g Specify Part No.; CDRS Rev. No. & Size Designation.
E
o
G G EXAMPLE: 8840-R/0- 6"
lEV

TFTN
BERGEN-POWER PIPE SUPPORTS PART 8840
v-
U CDRS CATALOG INFORMATION SHEET DATE 9/1 12007
CERTIFIED DESIGN REPORT SUMMARY

{FA
Ebd
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
GUIDE BASE WELDED TYPE

DIRECTION
OF
LOADING

Temperature: 600" F

NOte: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8860 R0


DESIGN REPORT NO.: DR-8860 R0
F lE' Rated Loads lor Classes 1,2,3 & MC
FV Design OPERATING CONDITIONS
PIPE SIZE Test Condition
Condition Level A Level B Level C Level D (see Note)

2 10000 10000 13300 15000 20000 13300


2 112 10000 10000 13300 15000 20000 13300
3 10000 10000 13300 15000 20000 13300
4 10000 10000 13300 15000 20000 13300
5 15000 15000 19950 22500 30000 19950
6 15000 15000 19950 22500 30000 19950
8 15000 15000 19950 22500 30000 19950
10 15000 15000 19950 22500 30000 19950
12 15000 15000 19950 22500 30000 19950
14 20000 20000 26600 30000 40000 26600
16 20000 20000 26600 30000 40000 26600
18 20000 20000 26600 30000 40000 26600
20 25000 25000 33250 37500 50000 33250
24 25000 25000 33250 37500 50000 33250

I certify this CDRS complies with the


requirements of the applicable Code.

Materials: The Design Report & Design Specification


N
o are in accordance with ASME BPVC Section lll,
Plate:3A-36
o
b Slide Bearinos: Graphite Subsection NF, 2007 Edition and are on file at:
tU
f
@
U) Bergen Power Pipe Supports, lnc.
J
Product Engineerlng DePartment
z
o Slide Bearings Exempt (NF-11 10)
tr CONTROLREFNO. 8860
o
PART NO.
Sheet

REV Certification
BERGEN.POWER PIPE SUPPOBTS, INC.
lof 3 n\ 8860
CERTIFIED DESIGN REPORT SUMMARY
rflf-
Hd
H
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
GUIDE BASE WELDED TYPE

DIRECTION
OF
LOADING

Temperature: 600 'F


NOte: The temperature shown above is for Design and Operating Conditions. For the Test Gondition (Hydro)
the maximum temperature is100f. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8860 R0


7 DESIGN REPORT NO.: DR-8860 R0
s
REV Rated Loads (lbs) lor Classes 1,2,3 & MC
FL Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Gondition Level A Level B Level C Level D (see Note)
2 500 500 665 750 1000 665
2 1t2 500 500 665 750 1000 665
3 500 500 665 750 1000 665
4 500 500 665 750 1000 665
5 1500 1500 1995 2250 3000 1995
6 1500 1500 1995 2250 3000 1995
I 2000 1500 1995 2250 3000 1995
10 2000 2000 2660 3000 4000 2660
12 2000 2000 2660 3000 4000 2660
14 4000 4000 5320 6000 8000 5320
16 4000 4000 5320 6000 8000 5320

18 4000 4000 5320 6000 8000 5320


20 5000 5000 6650 7500 10000 6650
24 5000 5000 6650 7500 10000 6650

rcenrry Inrs uuhD


"o.o@
equirements of the applicable Code. I

Materials: The Design Report & Design Specification


t-
o )late:5A-36 are in accordance with ASME BPVC Section lll,
o
o) Slide Bearinqs: Graphite Subsection NF, 2007 Edition and are on file at:
Llt
f
o
a Bergen Power Pipe Supports, lnc.
J
Product Engineering Department
z
Itr Slide Bearings Exempt (NF-11 10)
o ]ONTROL REF NO. 8860
PART NO.
Sheet
BERGEN.POWER PIPE SUPPORTS, INC. Zot 3 8860
REV Certilication

^\
IM
HHd
CERTIFIED DESIGN REPORT SUMMARY
for
NUCLEAR POWER PLANT STANDARD SUPPORTS
GUIDE BASE WELDED TYPE

DIRECTION
OF
LOADING

Temperature: 600 " F

Note: The temperature shown above is for Design and Operating Conditions. For the Test Condition (Hydro)
the maximum temperature is 100"F. For higher temperatures in the Test Condition use Level B loads
up to the temperature shown for the Operating Condition.

DESIGN SPEC NO.: DS-8860 R0


DESIGN REPORT NO.: DR-8860 R0
REV Rated Loads (lbs) lor Glasses 1,2,3 & MC
FL Design OPERATING CONDITIONS Test Condition
PIPE SIZE
Condition Level A Level B Level C Level D (see Note)
2 250 250 333 375 500 333
21t2 250 250 333 375 500 333
3 250 250 333 375 500 333
4 250 250 333 375 500 333
5 500 500 665 750 1000 665
6 500 500 665 750 1000 665
I 500 1500 1995 2250 3000 1995
10 1000 1000 1330 1500 2000 1330
12 1000 1000 1330 1500 2000 1330
14 2000 2000 2660 3000 4000 2660
16 2000 2000 2660 3000 4000 2660
18 2000 2000 2660 3000 4000 2660
20 2500 2500 3325 3750 5000 3325
24 2500 2500 3325 3750 5000 3325

lcertity this CDRS compnes witn tne I


requirements of the applicable Code. I

Materials: The Design Report & Design Specification


t-
o rlate:5A-36 are in accordance with ASME BPVC Section lll,
o Subsection NF, 2007 Edition and are on file at:
O) 3lide Bearinos: Graohite
lrJ
f,
a
L Bergen Power Pipe Supports, Inc.
J
Product Englneerlng DePartment

I(r
= Slide Bearings Exempt (NF-11 10)
o 3ONTROLREFNO. 8860
PART NO.
Sheet
A
REV.
BERGEN.POWER PIPE SUPPORTS, INC. 8860
REV Certilication lof 3
'f'
GUIDE BASE WELDED TYPE

r/4"

7/
/8
,, l//2 ,,

TYP.

PIPE
STZE A c ]F
2" -16" 4" 7 r/4" 4"
19" -?o" 7" 10 3 /4" 4"
Ct 6 24" 7" n r/4" 5" 4"
lEV

NOTES: 1 . All dimensions are in inches.

F-
2. Dimensions are Drovided for user application onlv.
o 3. For use with 8460 & 8560.
o
F

o)
I.JJ
f
U)
U) ORDERING INSTRUCTIONS:
J
z
g Specify Part No.; CDRS Rev. No. & Size Designation
(E
o
G EXAMPLE: 8860-R/0- 6"
REV

ffi
fl
BERGEN-POWER PIPE SUPPORTS
CDRS CATALOG INFORMATION SHEET
PART
DATE
8860
9t112007
( THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK )
EXECUTIVE OFFICES
MASSACHUSETTS
225 Merrimac Street
Woburn, MA 01801
Tel: 781.935.9550
Fax: 781.938.0026
e-mail: bpwoburn@bergenpower.com

MANUFACTURING PLANT
PENNSYLVANIA
484 Galiffa Drive
Donora Industrial Park
Donora, PA 15033
Tel: 724.379.5212
Fax: 724.379.9363

Вам также может понравиться