Академический Документы
Профессиональный Документы
Культура Документы
ModernPowerSystems
COMMUNICATING POWER TECHNOLOGY WORLDWIDE
Combined cycle
Capture ready CCGT:
what does it really mean?
Nuclear power
UAE takes the next steps,
while Koreans look to APR+
Renewables
European offshore wind:
outlook fair to good
Navigating the hazards
of offshore consenting
Putting marine energy
on trial in Scotland
Gas turbine
technology
Using membranes to filter
out compressor problems
Recips
Diesel gensets take off at
Larnaka
EXPPERTS
2010
Berlin, Germany
27-28 September 2010
www.arena-international.com/expperts2010
GAS TURBINE TECHNOLOGY
C
ompressor fouling and blade thereabouts), without the penalty of increased
corrosion due to ingress of pressure drop or shorter filter life.
contaminants in the incoming air The key is the 3-layer membrane structure,
(dust, soot, salt, etc) has been an all too see Figure 1. Conventional F9 media
common problem for gas turbine operators, The pre-filter layer removes the bulk of
requiring frequent compressor washing – coarse and submicron particles storing them
which itself has been implicated in some depth-wise, with a minimal increase in
instances of compressor blade cracking, pressure drop.
notably in the case of FA machines. The second layer consists of an ePTFE
Improved filtering of the incoming air membrane that removes the smallest particles,
Gore E12 membrane based media
(about 2 million m3 per hour for a large gas water and dissolved salt crystals. As this
turbine, typically containing around 50 g per membrane provides a huge surface area due to
hour of dust) is an obvious route to take – its nanostructure it achieves very high
bearing in mind that over 99% of atmospheric filtration efficiency, water tightness and salt
particles have diameters of less than 1 µm. repellence.
But there have been downsides with When becoming wet over long periods of
increased filtration. For example, higher levels high relative humidity, standard nano-fibre
of filtering efficiency can result in higher glass media tend to unload accumulated
pressure drops, and even the filters themselves particles and salt (leeching effect) into the
can be a source of corrosive particles due to compressor, resulting in fouling and corrosion.
reactions between salt and water within the In contrast, the ePTFE membrane is
filter media. Also, conventional HEPA filters hydrophobic and therefore not susceptible to
require an additional pre-filter stage if water ingress and salt penetration (Figure 2). no salt penetration
adequate lifetime is to be achieved. Furthermore, its nanometer-scale fibrils
Membrane based (as opposed to and nodes keep the pressure drop at a low level Figure 2. Salt test: 72 h salt fog plus 24 h
“conventional” micro or nano fibre glass due to the so called slip-flow. In contrast to drying. The Gore membrane based media
based) HEPA filters are proving an effective micrometer-size fibres the drag force on a shows no salt penetration
way to steer through these issues, and have been nanometer-scale fibril is smaller as the
applied to increasingly large gas turbines in the molecular movement of the air molecules
six years or so since they were first introduced contributes to the overall airflow. This slip- Figure 3. Square,
by W. L. Gore & Associates, with excellent flow regime results in a lower pressure drop. cylindrical, and conical
performance being reported from the field. The third layer is a high strength backer, panels with the Gore
which provides high burst strength even when membrane-based HEPA
Three layers wet. Wet burst tests of cartridge and panel media
The GORE® Turbine Filter uses membranes filter elements containing this media show
made of ePTFE (expanded polytetrafluo- burst pressures well above 6200 Pa.
roethylene) and achieves the remarkable feat The combination of these three filtration
of increasing the filtration efficiency to the layers is pleated and integrated into standard
E12/H12 level (which means they keep out at cartridge (cylindrical) or panel (square)
least 99.5% of contaminants at the most designs (Figure 3), which can be easily
penetrating particle size of 0.1 µm or retrofitted into nearly all types of existing gas
turbine filter houses (unlike micro fibre glass of existing filter houses are needed, such as Remarkably, all sites have reported the
media, which are only available in square shapes). that needed to accommodate an additional elimination of compressor fouling and a filter
In addition, to take full advantage of the pre-filter stage. Consequently, just about any life similar to the F8 or F9 rated cartridge
membrane-based technology, a new Z- gas turbine can benefit from H12/E12 HEPA filters used before.
configuration panel design was developed (see filtration with a low pressure drop and a According to Wilson Poon, Research &
Figure 4). This Z configuration results in reasonable filter life-time. Development leader for GORE® Turbine Filters,
about half of the pressure drop (135 Pa at 3400 “customers who installed the new technology
m3/h airflow, 180 Pa at 4250 m3/h airflow) How are the membrane filters experienced within a matter of weeks significant
compared with H12 V-shaped panels using performing in the field? power output and efficiency increases relative
micro fibre glass media. Installations of GORE® Turbine Filters what they would have been with their incumbent
The membrane-based media (be it either Z containing the new membrane-based media go filters...due to capture of the submicron particles
or V shaped) require only one pre-filter stage, back to the end of 2004, initially at relatively by the filter’s membrane layer.”
the preferred pre-filter class being G4 or F5, small facilities, and their performance has
depending on application. No modifications been extensively monitored. TransCanada experience
Gore worked with TransCanada Corporation
Figure 5. Used compressor washing fluids to field test the new filter in a direct
from two adjacent GE LM6000 turbines. comparison with a nano fibre filter in identical
Left: 1st turbine after 1450 operating hours LM6000 turbines.
with F9 rated nano fibre filters. Right: 2nd After 1450 operating hours, an off-line wash
turbine after 2500 operating hours with the was performed on the compressor section of the
membrane based Gore filter turbine that had the nano fibre filters. The
resultant used wash fluid was black, indicating
significant fouling of the compressor. However,
after 2500 hours of operation, an off-line wash
performed on the turbine with the Gore filter
yielded white effluent, with no evidence of particle
contamination. Figure 5 illustrates the point.
Despite running the Gore installation nearly twice
Figure 6. Boroscope picture of compressor as long as the other one before the wash there is
section of LM6000 fitted with Gore filter, after virtually no dirt to wash off during the soak
10600 hours, showing totally clean blades washes, hence the milky white wash fluid.
Rick MacDonald, plant manager at
Figure 7. Power output variance from corrected target. Red: conventional F9 filter with 2 offline TransCanada Corporation’s Grandview
washings. Blue: Gore H12 filter without any washings power plant in New Brunswick, sums up his
experience thus: “Prior to installation of the
new filters, we were required to offline soak-
wash each of our turbines every five to six
weeks, and we typically experienced up to
1 MW of power loss on each 44 MW turbine
between washes. With the Gore filters, we now
operate for four months between washing, and
we do not see any power loss at all. In fact, the
turbine power output and heat-rate have held
steady for the entire 18 months of filter
operation so far, and we expect to get two or
more years of total service life. What a
difference in performance!”
He also notes that the installation of the filters
was simple – a direct replacement “of our old
filters with the Gore filters” – and that “use of the
filters has resulted in a clean turbine compressor
section from initial installation to-date.”
Figure 6 shows the compressor section of the
LM6000 fitted with the Gore filter, after 10 600
hours of operation. This explains why the
wash fluid in Figure 5 is white. The blades
appear unsoiled and the compressor section
seems “to be as clean as the day we installed
the Gore filters,” says Rick MacDonald.
RB211 in the UK
Figure 8. Compressor running with F9 filter, left, and with Gore H12 filter, right Another example is a Rolls-Royce RB211 31 MW
gas turbine running in baseload at an industrial
Figure 9. Total inlet pressure drop over time, F9 filter vs Gore H12 filter site on the western coast of England (as reported,
along with the other case studies mentioned
below, in a paper* presented at PowerGen
Europe, Amsterdam, June 2010). The single stage
filter house contains 112 pairs of conical and
cylindrical cartridges and was originally equipped
with standard F9 rated filters.
Operating the gas turbine with this level of
filtration, the operator, E.ON UK,
experienced significant power loss, up to 3
MW before an offline washing due to
compressor fouling (left side of Figure 7). The
left side of Figure 8 shows the fouled
compressor resulting from operation with the
F9 filtration. Offline washing needed to be compressor washings were required. Figure 8, compressor fouling, with no observed
scheduled about every 2 months. right hand side, shows the clean compressor reduction in compressor efficiency and gas
In March 2008, GORE® Turbine Filters after about 2000 hours running with the Gore turbine power output capability.
were installed, including an additional pre- H12 filters and no washing.
filter wrap. When running the gas turbine with Looking at operating life, the new Gore H12 9FA in Spain
these H12 cartridges neither compressor filters exhibited a pressure drop over time Some 700 H12 Gore cartridge pairs were
fouling nor a drop in power output was comparable with the previous F9 rated installed at a GE Frame 9FA in Spain in
observed (Figure 7, right hand side). So no cartridges (Figure 9) – but also eliminated November 2009, at an industrial site about two
km from the Mediterranean Sea. The operator
Figure 10. Performance data for Gore cartridge pair installed on GE Frame 9FA, Spain had experienced corrosion and compressor
fouling with the previously installed F9 filters.
After installation of the new filters, no such
problems have been encountered. There has
been no decline in power output capability due
to the compressor, and no significant increase
in pressure drop across the filters.
Figure 10 shows performance data for the first
three months following the change of filters.