Вы находитесь на странице: 1из 2

ALJ Electronics, Inc.

El Segundo, CA
0315 CJ

ALJ QUICK GUIDES


EDC Dryer Controls 120V / 24V
Changing Price (Manually)

VEND PRICE CHANGE


Note: Tumbler must be in “Ready” mode. Make sure no coins have been entered and the control
is not in an active cycle.
1. Open and close service door.
2. Press and hold HIGH TEMP, then press MED TEMP.
3. “SPC” will appear on the display.
4. Press and hold HIGH TEMP, then press MED TEMP.
5. “Sig” will appear on the display.
6. Press LOW TEMP pad until “nCL” appears on the display.
7. Press START to display current number of minutes per quarter.
8. Press LOW TEMP (+) or NO HEAT (-) to change the number.
9. Press START to save this number.
10. Press the LOW TEMP (+) or the NO HEAT (-) to scroll through the program until “Add”
appears on the display. This is the additional time / minutes per quarter.
11. Press START to show the current value.
12. Adjust the value, see table: Press the LOW TEMP (+) or the NO HEAT (-) to change the
number where:
VALUE = 128 + desired ADDITIONAL MINUTES.
i.e. at 15 minutes per quarter, value = “143”
at 10 minutes per quarter, value = “138”
13. Press START to save this number.
14. Press the LOW TEMP (+) or the NO HEAT (-) to scroll through the program to the next
step that needs to be changed. IF DONE, goto step 20.
15. Press START to show the current value.
16. Adjust the value, see table for guidelines.
17. Press START to save this number.
18. Repeat steps 15-19 for whatever feature needs to be changed.
19. When done, press HIGH TEMP, then press MED TEMP. Control returns to “Ready”
mode.

For more information or to change other settings, see EDC Programming and Operating
Instructions Manual (p/n M411843R2).

NORMAL DELICATES
HIGH START LOW
TEMP TEMP

PERM TUMBLE
PRESS NO
MED TEMP HEAT

Page 1 of 2
ALJ Electronics, Inc.
El Segundo, CA
0315 CJ

For more information or to change other settings, see EDC Programming and Operating
Instructions Manual (p/n M411843R2).

Step Display Description Comments Value


1 “SIg” Audio Signal
2 “nPr” Normal Vend Price number of 001 = 1 quarter
quarters to start
3 “SPA” Special Vend A On/Off Days of Week
4 “AnP” Special Vend A Normal Price
5 “AFP” Special Vend A NO HEAT price
6 “AnL” Special Vend A Normal Time
7 “AFL” Special Vend A NO HEAT Time
8 “ASH” Special Vend A Start Hour
9 “AEH” Special Vend A End Hour
10 “nCL” Normal Cycle Time (HIGH, MED, LOW) minutes to start at 010 = 10 min/quarter
normal vend 012 = 12 min/quarter
015 = 15 min/quarter
…etc…
11 “HCL” HIGH TEMP Cool Down Time minutes 002 = 2 minutes
003 = 3 minutes
…etc…
12 “HdE” HIGH TEMP Temperature
13 “PCL” MED TEMP Cool Down Time minutes 002 = 2 minutes
003 = 3 minutes
…etc…
14 “PdE” MED TEMP Temperature
15 “LCL” LOW TEMP Cool Down Time minutes 002 = 2 minutes
003 = 3 minutes
…etc…
16 “LdE” LOW TEMP Temperature
17 “Add” Additional Time Additional 136 = 8 min
minutes per 138 = 10 min
quarter 140 = 12 min
Value = 143 = 15 min
128+minutes …etc…
18 “FPr” NO HEAT Vend Price number of 001 = 1 quarter
quarters to start
19 “FCL” NO HEAT Cycle Time minutes per 010 = 10 min/quarter
quarter 012 = 12 min/quarter
015 = 15 min/quarter
…etc…
20 “COI” Coin Value
21 “dCS” Default Cycle Status
22 “rPF” Reset After a Power Failure
23 “CFg” Control Configuration
24 “Cln” Set Real-Time Clock (minutes)
25 “CHr” Set Real-Time Clock (hours)
26 “CdA” Set Real-Time Clock (days of week)
27 “CdE” Set Real-Time Clock (date)
28 “Con” Set Real-Time Clock (month)
29 “Cyr” Set Real-Time Clock (year)

Page 2 of 2