Вы находитесь на странице: 1из 6

Omron Weighing Indicator

Initial Setting Level LO-:

1) Press Level button for min 3 sec.


Displays “in-tA “ To change values in-tA Press Shift
button first then by up key set the
value to bLC for Input type B.

2) Press Mode key to go next option i.e FrE" is put to 50 Hz.

3) Press Mode key 4 times for decimal point selection.

Displays “dP" By pressing Shift Key adjust the


decimal point.

Input adjustment level Ll

4) Press Level button,


Displays 11E-Lim" Set it OFF by pressing Shift and up
key.
5) Press Mode key
Displays 11StEP" press shift & up key set the value
OFF.
6) Press Mode
Displays II AuG-t" pressing shift & up key set the value Sn
Pl.
7) Press mode
Displays "AuG-n" pressing Shift & up key set the value 1.

8) Press Mode
Displays memo pressing Shift & up key set it on.

Display Adjustment level L2

9) Press Level button,


Displays "d.rEF" pressing Shift & up key set it OFF.

10) Press Mode


Displays "Color" press shift and then by pressing up
key set the colour as required.
11) Press mode
Displays "dCSP" press shift key & then by pressing up
key set the value Pv.
12) Press mode
Displays "rEt" press shift key & then by pressing up
key set the value 10.
13) Press mode
Displays "PoS-t" Press shift key & then by pressing up
key set the value inc.
14) Press mode
Displays "PoS-H" Press shift key & then by pressing up
key set the value as required.(Max
capacity of Hooper, e.g.3000)
15) Press mode
Displays "PoS-L" Press shift key & then by pressing up
key set the value as required. (Agg=-
30, Cement=-10, Water=-10,
Addmixer=-0.5)

Linear output level Ls

16) Press Level button,


Displays "Lset.u" Then press shift & up key set the value
as required (e.g. 0 to Sv, 1 to Sv, 0 to 10v)

17) Press mode


Displays "Lset.H" Press shift key & then by pressing up
key set the value as required. (Max
capacity of Hooper, e.g.3000)
18) Press mode
Displays "LSet. Press shift key & then by pressing up
L" key set the value as required.(Agg=- 30
Cement=-10 Water=-
, I

10,Admixture=-0.5)

19) Press level key For 3 sec.


Calibration Process

1) Press level key For 3 sec.

Displays "in-tA"

2) Press Mode key 2 times


(Keep Hooper empty)
Displays "inP.Al"
Press up it shows some value, to
stable press up key again.

3) Press Mode key


Displays "dSP.Al" with Shift & up Key value must be
keep zero.
4) Press Mode key
Displays "inP.A2" Put weight on hooper which is 80% of
max capacity of Hooper For greater
accuracy.

Press up it shows some value, to


stable press up key again.

5) Press Mode key


Pressing Shift & Up key set the value of
Displays "dSP.A2"
weight which is put on hooper.
Change the settings

Use the Shift and Up key to change the settings. The setting to be
changed will flash.

Note-: If a key is not pressed within Ss, the present setting will be
saved and the display will return to monitor mode.

Abbreviations

ln-tA Input type

FrE Power Frequency

inP.Al Scalling input value Al

dSP.Al Scalling display value Al

inP.A2 Scalling input value A2

dSP.A2 Scalling display value A2

dP Decimal Point position

E-Lim Zero limit

StEP Step value

AuG-t Average type

AuG-n Averaging times

mEmo Power interruption memory

d.rEF Display refresh period


Color Display color selection
Di SP Display Value Selection

rEt Automatic display return

PoS-t Position meter type

PoS-H Position meter upper limit

PoS-L Position meter lower limit

Lset.u Linear voltage model

Lset.H Linear output upper limit

LSet.L Linear output lower limit

Вам также может понравиться