Shutdown SIS

Previous Screen

Product: GENERATOR SET


Model: G3520B GENERATOR SET GZP
Configuration: G3520B Generator Set GZP00001-UP

Operation and Maintenance Manual


G3500B Generator Sets
Media Number -SEBU7566-07 Publication Date -01/10/2012 Date Updated -10/10/2012

i01494879

Varistor - Test
SMCS - 4466-081

Illustration 1 g00677004

29/05/2018
Página 2 de 3

PMPE Generator Wiring Diagram

(CR1-CR6) Diodes

(CR7) Varistor

(L1) Exciter field (stator)

(L2) Exciter armature (rotor)

(L3) Main field (rotor)

(L4) Main armature (stator)

(L5) Pilot exciter armature

(PM) Permanent magnet

(RFA) Rotating field assembly

(CST) Customer supplied transformer

Ohmmeter
An ohmmeter can be used to check a varistor (CR7). Place an ohmmeter across the varistor. The
resistance should be a minimum of 15000 ohms. If the resistance is less than 15000 ohms, the varistor is
faulty.

Test Light

Illustration 2 g00555113

Test Light

Refer to the test light that is shown in Illustration 2. Follow these steps in order to test the varistor:

1. Disconnect either lead of the varistor (CR7) .

2. Place the test light across the varistor.

29/05/2018
Página 3 de 3

3. Observe the results. The lamp should not light.

4. Reverse the test light.

5. Observe the results. The lamp should not light.

If the test light illuminates in either direction, there is a short in the varistor. Replace any faulty
varistors with varistors that have comparable operating characteristics. Include the following
information when a varistor is being ordered for replacement:

Part number of the varistor

Serial number of the generator

After the varistor has been replaced, verify that the strapping of the field winding lead is securely
wound on the shaft. Also, verify that the strapping of the field winding lead is securely tied.

Copyright 1993 - 2018 Caterpillar Inc. Tue May 29 18:17:44 UTC-0400 2018