Вы находитесь на странице: 1из 3

HITACHI OIL-FREE SCREW COMPRESSOR

OIL FREE SCREW SINGLE STAGE(15/22/37/55kW)

Specifications
■ Air-Cooled, Fixed Speed Model (15−55kW) [ ]: indicates model with Dryer integrated
Model DSP-15A[R]5N DSP-22A[R]5N DSP-37A[R]5N DSP-55A[R]5N
Item・Unit DSP-15A[R]6N DSP-22A[R]6N DSP-37A[R]6N DSP-55A[R]6N
Discharge Pressure MPa 0.7 0.4 0.7 0.4 0.7 0.4 0.7 0.4
Discharge Air Capacity m3/min 2.0 2.5 3.4 4.0 5.0 5.9 6.4 8.0
Nominal Motor Output kW 15 22 37 55
Motor Type − 4-Pole TEFC Motor
Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 [5–40]

SINGLE STAGE(15/22/37/55kW)
Discharge Temperature ˚C Ambient Temperature +15 or below
Discharge Air Pipe Connection B Rc1 Rc1-1/2
Starting Method − Full Voltage Start Star-Delta (3 contact)
Driving Method − V-Belt+Gear-Driven
Oil Quantity L 12 (Not filled) 18 (Not filled)
Cooling Fan Motor Output kW 0.4 0.75 0.9
Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3
P.D.P ˚C [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] −
[Dryer] Refrigerator Nominal Output kW [0.5] − [1.1] − [1.1] − [1.1] −
Refrigerant − [R407C] − [R407C] − [R407C] − [R407C] −
Weight kg 750 [780] 800 [860] 1,020 [1,170] 1,240 [1,390]
Dimensions (W×D×H) mm 1,400×970×1,400 1,830×980×1,580 [2,230×980×1,580]
Sound Level (1.5m from front) dB(A) 62 63 63 64 66 68 68 70

■ Air-Cooled, V-type Model (22−55kW) [ ]: indicates model with Dryer integrated
Model DSP-22VA[R]5N DSP-37VA[R]5N DSP-55VA[R]5N
Item・Unit DSP-22VA[R]6N DSP-37VA[R]6N DSP-55VA[R]6N
Discharge Pressure MPa 0.7 0.3 0.7 0.3 0.7 0.3
Discharge Air Capacity m3/min 3.4 4.6 5.0 6.7 6.4 8.5
Discharge Pressure MPa 0.6 − 0.6 − 0.6 − Asia & Oceania India Thailand Russian Federation
PQ Discharge Air Capacity m3/min 3.7 − 5.5 − 7.0 − China Hitachi India Pvt. Ltd. Hitachi Asia (Thailand) Co., Ltd. Hitachi, Ltd. (Moscow Office)
WIDEMODE Discharge Pressure MPa 0.4 [0.5] − 0.4 [0.5] − 0.4 [0.5] − Hitachi Industrial Equipment Systems Units 304-306, 3rd Floor, ABW Elegance 18th Floor, Ramaland Building, 952 Millenium House, 12, Trubnaya, Moscow
(China) Co., Ltd. Tower, Jasola District Centre, New Delhi Rama IV Road Bangrak, Bangkok 10500 103045
Discharge Air Capacity m3/min 4.3 [4.0] − 6.4 [6.0] − 8.2 [7.6] −
(Shanghai Branch) 110 025, India TEL : +66 (2) 632-9292 TEL : +7 (095) 787-4022, -4020
PQ WIDEMODE Range MPa 0.4–0.7 [0.5–0.7] − 0.4–0.7 [0.5–0.7] − 0.4–0.7 [0.5–0.7] −
Room1207, Rui Jin Building, No.205 TEL : +91 (11) 4060-5252 FAX : +66 (2) 632-9299 FAX : +7 (095) 787-4021
Nominal Motor Output kW 22 37 55
Maoming Road(S) Shanghai 200020 FAX : +91 (11) 4060-5253
Motor Type − 4-Pole TEFC Motor TEL : +86 (21) 5489-2378 Viet Nam Latin America
Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 [5–40] FAX : +86 (21) 3356-5070 Indonesia Hitachi Asia Ltd. Mexico
Discharge Temperature ˚C Ambient Temperature +15 or below (Beijing Branch) PT Hitachi Asia Indonesia (Ho Chi Minh City Office) Hitachi Industrial Equipment
Discharge Air Pipe Connection B Rc1-1/2 Room1420, Beijing Fortune Building, Menara BCA 38th Floor Suite #3804 & 4th Floor, The Landmark, 5B Ton Duc Mexico S.A. de C.V.
Starting Method − Inverter No.5 Dong San Huan Bei Road, 3805 JI. M. H Thamrin No.1, Jakarta Thang Street District 1, Ho Chi Minh City Avenida Rio Seguro 161, Parque Tecno
Driving Method − V-Belt+Gear-Driven Chao Yang District, Beijing 100004 10310, Indonesia TEL : +84 (8) 829-9725 Industrial Castro del Rio Tramo
Oil Quantity L 12 (Not filled) 18 (Not filled) TEL : +86 (10) 6590-8180 TEL : +62 (21) 2358-6757 FAX : +84 (8) 829-9729 Irapuato-Silao km125, Carretera
Cooling Fan Motor Output kW 0.75 0.9 FAX : +86 (10) 6590-8189 FAX : +62 (21) 2358-6755 (Ha Noi Office) Panamericaa C.P.36810, Irapuato, Gto.,
(Guangzhou Branch) Sun Red River Bldg., 5th Floor, Mexico
Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3
P.D.P ˚C [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] −
Room3403, Office Tower, CITIC Plaza , Malaysia 23 Phan Chu Trinh Street TEL : +52 (462) 693-7088, -7089, -7090
No.233 Tianhe North Road, Guangzhou Hitachi Asia (Malaysia) Sdn. Bhd. Hoan Kiem District, Hanoi FAX : +52 (462) 693-7091
[Dryer] Refrigerator Nominal Output kW [1.1] − [1.1] − [1.1] −
510613 Suite 17.3, Level 17, Menara IMC TEL : +84 (4) 933-3123
Refrigerant − [R407C] − [R407C] − [R407C] − TEL : +86 (20) 3877-0438 (Letter Box No.5) No. 8 Jalan Sultan FAX : +84 (4) 933-3125 North America
Weight kg 850 [910] 1,080 [1,230] 1,180 [1,330] FAX : +86 (20) 2735-3820 Ismail, 50250, Kuala Lumpur U.S.A.
Dimensions (W×D×H) mm 1,650×970×1,400 1,830×980×1,580 [2,230×980×1,580] TEL : +60 (3) 2031-8751 Australia Hitachi America, Ltd.
Sound Level (1.5m from front) dB(A) 63 64 66 68 68 70 Hitachi Industrial Equipment Systems FAX : +60 (3) 2031-8758 Hitachi Australia Pty Ltd. (Industrial Components & Equipment
(HongKong) co., Limited Level 8, 123 Epping Road, Macquarie Division)
■ Water-Cooled Model (37/55kW) [ ]: indicates model with Dryer integrated 6th Floor, North Tower World Finance Philippines Park NSW 2113 50 Prospect Avenue, Tarrytown,
Model Fixed Speed Model V type Centre, Harbour City, Canton Road, Hitachi Asia Ltd. Philippine Branch TEL : +61 (2) 9888-4100 New York, 10591-4698
DSP-37W5N DSP-55W5N
Tsim Sha Tsui, Kowloon Hong Kong Unit 8, 11th Floor Zuellig Bldg., FAX : +61 (2) 9888-4188 TEL : +1(914) 332-5800
DSP-37VWN DSP-55VWN TEL : +852 2735-9218 Makati Avenue corner Paseo de Roxas FAX : +1(914) 332-5555
Item・Unit DSP-37W6N DSP-55W6N
Discharge Pressure MPa 0.7 0.4 0.7 0.4 0.7 0.3 0.7 0.3
FAX : +852 2735-6793 Makati City, Philippines 1225 Europe (Charlotte Office)
TEL : +632 886-9018 Germany (Industrial Components & Equipment
Discharge Air Capacity m3/min 5.0 5.9 6.4 8.0 5.0 6.7 6.4 8.5
Taiwan Hitachi Asia Pacific Co., Ltd FAX : +632 887-3794 Hitachi Europe GmbH Division)
Discharge Pressure MPa − − − − 0.6 − 0.6 − 3th Floor, No. 167, Tun Hwa N. Road, (Industrial Components & Equipment 6901 Northpark Blvd., Charlotte, NC 28216
PQ Discharge Air Capacity m3/min − − − − 5.5 − 7.0 − Hung-Kuo Building, Taipei 10512, Taiwan Singapore Group) TEL : +1(704) 494-3008
WIDEMODE Discharge Pressure MPa − − − − 0.4 − 0.4 − TEL : +886 (2) 2718-3666 Hitachi Asia Ltd. Am Seestern 18 (Euro Center) FAX : +1(704) 494-3809
Discharge Air Capacity m3/min − − − − 6.4 − 8.2 − FAX : +886 (2) 2514-7664 (Industrial Components & Equipment D-40547 Düsseldorf
PQ WIDEMODE Range MPa − − − − 0.4–0.7 − 0.4–0.7 − Group) TEL : +49 (211) 5283 0
Nominal Motor Output kW 37 55 37 55 No.30, Pioneer Crescent FAX : +49 (211) 5283 649
Motor Type − 4-Pole TEFC Motor 4-Pole TEFC Motor #10-15, West Park Bizcentral
Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 Atmospheric Pressure/0–40 Singapore 628560
TEL : +65-6305-7400
Discharge Temperature ˚C Cooling Water Temperature +13 or below Cooling Water Temperature +13 or below
FAX : +65-6305-7401
Discharge Air Pipe Connection B Rc1-1/2 Rc1-1/2
Starting Method − Star-Delta (3 contact) Inverter
Driving Method − V-Belt+Gear-Driven V-Belt+Gear-Driven
Oil Quantity L 14 (Not filled) 14 (Not filled)
Cooling Fan Motor Output kW 0.1 0.2
Cooling Water Flow Rate L/min 80 80
Cooling Water Temperature ˚C 32 or below 32 or below
Cooling Water Pipe Connection B Rc1 Rc1
Weight kg 970 1,190 1,050 1,150
Dimensions (W×D×H) mm 1,830×980×1,580 1,830×980×1,580
Sound Level (1.5m from front) dB(A) 64 66 64 66 64 66 64 66
NOTE:
1. Capacity is measured according to ISO 1217, Third Edition, Annex C. 7. Pressure is indicated as the gauge pressure.
2. Sound Levels is the value at 1.5m in front and 1m height in an anechoic room. 8. Dimensions do NOT include protruding objects such as piping.
It varies in different operating conditions and/or different environment with echo of actual 9. Specifications and/or appearances are subject to change without notice.
field installations.
For V-type models, sound level is increased by 2dB at PQ WIDEMODE ON.
ISO14001 ISO9001
D S P - 37 V A R 5 N EC97J1107 JQA-QM3443
3. P.D.P is measured at 30˚C of intake air temperature and rated discharge pressure.
P.D.P is much worse at 0.4MPa or less of discharge pressure. Dry DSP Hitachi Screw Compressor is manufactured at a factory approved by Environmental Standard
P.D.P rises 3˚C at PQ WIDEMODE ON and 0.6MPa of discharge pressure. Screw Frequency (5:50Hz, 6:60Hz) (ISO 14001) and Quality Standard (ISO9001) of International Organization for Standardization.
4. Air Capacity of Built-in Dryer model decreases by up to 3% when drain condensates. Package R:Built-in Dryer (Without R:without dryer type)
5. Discharge air temperature with Dust Proof option or Simple Package Filter option is Nominal A:Air-cooled, W:Water-cooled
ambient temperature + 18˚C or below. Output (kW) V:V-type (Without V:Fixed Speed type)
6. Earth leakage circuit breaker is NOT equipped within. Prepare it in advance.

2 E177 1214
Hitachi Original Oil-free Screw Technology – OIL FREE SCREW SINGLE STAGE(15/22/37/55kW)

Single-Stage Up to 0.7MPa Specifications


■ Air-Cooled, Fixed Speed Model (15−55kW) [ ]: indicates model with Dryer integrated
Instrumental Panel Model DSP-15A[R]5N DSP-22A[R]5N DSP-37A[R]5N DSP-55A[R]5N
Item・Unit DSP-15A[R]6N DSP-22A[R]6N DSP-37A[R]6N DSP-55A[R]6N
Discharge Pressure MPa 0.7 0.4 0.7 0.4 0.7 0.4 0.7 0.4
Discharge Air Capacity m3/min 2.0 2.5 3.4 4.0 5.0 5.9 6.4 8.0
Air-End Nominal Motor Output kW 15 22 37 55
Motor Type − 4-Pole TEFC Motor
Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 [5–40]
Inverter Discharge Temperature ˚C Ambient Temperature +15 or below
Gear Case Discharge Air Pipe Connection B Rc1 Rc1-1/2
Starting Method − Full Voltage Start Star-Delta (3 contact)
Driving Method − V-Belt+Gear-Driven
Oil Quantity L 12 (Not filled) 18 (Not filled)
Cooling Fan Motor Output kW 0.4 0.75 0.9
Main Motor Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3
Control Panel P.D.P ˚C [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] −
[Dryer] Refrigerator Nominal Output kW [0.5] − [1.1] − [1.1] − [1.1] −
Refrigerant − [R407C] − [R407C] − [R407C] − [R407C] −
Weight kg 750 [780] 800 [860] 1,020 [1,170] 1,240 [1,390]
Dimensions (W×D×H) mm 1,400×970×1,400 1,830×980×1,580 [2,230×980×1,580]
Sound Level (1.5m from front) dB(A) 62 63 63 64 66 68 68 70

■ Air-Cooled, V-type Model (22−55kW) [ ]: indicates model with Dryer integrated
Model DSP-22VA[R]5N DSP-37VA[R]5N DSP-55VA[R]5N
*The above picture shows the internal structure Item・Unit DSP-22VA[R]6N DSP-37VA[R]6N DSP-55VA[R]6N
of 55kW Air-Cooled model (V-type). Discharge Pressure MPa 0.7 0.3 0.7 0.3 0.7 0.3
Discharge Air Capacity m3/min 3.4 4.6 5.0 6.7 6.4 8.5
Discharge Pressure MPa 0.6 − 0.6 − 0.6 −
PQ Discharge Air Capacity m3/min 3.7 − 5.5 − 7.0 −
WIDEMODE Discharge Pressure MPa 0.4 [0.5] − 0.4 [0.5] − 0.4 [0.5] −

Premium Air Quality Discharge Air Capacity


PQ WIDEMODE Range
m3/min
MPa
4.3 [4.0]
0.4–0.7 [0.5–0.7]


6.4 [6.0]
0.4–0.7 [0.5–0.7]


8.2 [7.6]
0.4–0.7 [0.5–0.7]


Nominal Motor Output kW 22 37 55
True Oil-free Air at Class 0 Level Motor Type − 4-Pole TEFC Motor
Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 [5–40]
Air purity class of the discharge air from Hitachi Oil-free Screw air compressor (DSP) is proved to be the ISO-8573-1 Discharge Temperature ˚C Ambient Temperature +15 or below
highest level “Class 0” from the test result which was conducted by the renowned TÜV institute, in Discharge Air Pipe Connection B Rc1-1/2
Starting Method − Inverter
accordance with ISO8573-1. Driving Method − V-Belt+Gear-Driven
Oil Quantity L 12 (Not filled) 18 (Not filled)
Cooling Fan Motor Output kW 0.75 0.9
Coolant Pump Motor Output (50/60Hz) kW 0.2/0.3
■ ISO8573-1:2010 CLASS 0 TÜV Certification P.D.P ˚C [10 (Under Pressure)] − [10 (Under Pressure)] − [10 (Under Pressure)] −
[Dryer] Refrigerator Nominal Output kW [1.1] − [1.1] − [1.1] −
TÜV (The Technische Überwachungs Verein), a Refrigerant − [R407C] − [R407C] − [R407C] −
Germany based international test service provision Weight kg 850 [910] 1,080 [1,230] 1,180 [1,330]
Dimensions (W×D×H) mm 1,650×970×1,400 1,830×980×1,580 [2,230×980×1,580]
third-party on aspects of technical safety and quality Sound Level (1.5m from front) dB(A) 63 64 66 68 68 70
evaluation, is globally well-reputed on its neutrality
■ Water-Cooled Model (37/55kW) [ ]: indicates model with Dryer integrated
and expertise as well as its strictness in testing. Model Fixed Speed Model V type
DSP-37W5N DSP-55W5N
DSP-37VWN DSP-55VWN
Item・Unit DSP-37W6N DSP-55W6N
Discharge Pressure MPa 0.7 0.4 0.7 0.4 0.7 0.3 0.7 0.3
Discharge Air Capacity m3/min 5.0 5.9 6.4 8.0 5.0 6.7 6.4 8.5
Discharge Pressure MPa − − − − 0.6 − 0.6 −
PQ Discharge Air Capacity m3/min − − − − 5.5 − 7.0 −
WIDEMODE Discharge Pressure MPa − − − − 0.4 − 0.4 −
Discharge Air Capacity m3/min − − − − 6.4 − 8.2 −
High Performance Air-End Cut Down Overhaul and Initial Cost PQ WIDEMODE Range
Nominal Motor Output
MPa
kW

37
− −
55
− 0.4–0.7
37
− 0.4–0.7
55

Motor Type − 4-Pole TEFC Motor 4-Pole TEFC Motor


Stainless Steel Rotor Intake Air Pressure/Temperature ˚C Atmospheric Pressure/0–40 Atmospheric Pressure/0–40
100 100
Air-End Discharge Temperature ˚C Cooling Water Temperature +13 or below Cooling Water Temperature +13 or below
Particular stainless steel, Discharge Air Pipe Connection B Rc1-1/2 Rc1-1/2
which is superior in corrosion Starting Method − Star-Delta (3 contact) Inverter
50 50 Driving Method − V-Belt+Gear-Driven V-Belt+Gear-Driven
resistance and durability, is Oil Quantity L 14 (Not filled) 14 (Not filled)
applied for rotor with highly Cooling Fan Motor Output kW 0.1 0.2
Cooling Water Flow Rate L/min 80 80
accurate grinding. 0 0 Cooling Water Temperature ˚C 32 or below 32 or below
Furthermore, compensated Single-stage Two-stage Single-stage Two-stage Cooling Water Pipe Connection B Rc1 Rc1
Comparison of Comparison of Weight kg 970 1,190 1,050 1,150
profile, which is optimized for Dimensions (W×D×H) mm 1,830×980×1,580 1,830×980×1,580
Overhaul Cost (%) Initial Cost (%)
thermal expansion during Sound Level (1.5m from front) dB(A) 64 66 64 66 64 66 64 66
Example of Hitachi 55kW (single-stage) and 45kW (2-stage), without dryer model
NOTE:
operation, enables to keep 1. Capacity is measured according to ISO 1217, Third Edition, Annex C. 7. Pressure is indicated as the gauge pressure.
optimal clearance. 2. Sound Levels is the value at 1.5m in front and 1m height in an anechoic room. 8. Dimensions do NOT include protruding objects such as piping.
It varies in different operating conditions and/or different environment with echo of actual 9. Specifications and/or appearances are subject to change without notice.
Comparison of cost with the same air capacity level field installations.
For V-type models, sound level is increased by 2dB at PQ WIDEMODE ON.
High Performance Coating Because there is only one air end for DSP single-stage model, 3. P.D.P is measured at 30˚C of intake air temperature and rated discharge pressure. D S P - 37 V A R 5 N
P.D.P is much worse at 0.4MPa or less of discharge pressure. Dry DSP
Hitachi original coating, which can withstand the high tempera- the initial cost is lower than two-stage model. P.D.P rises 3˚C at PQ WIDEMODE ON and 0.6MPa of discharge pressure. Screw Frequency (5:50Hz, 6:60Hz)
4. Air Capacity of Built-in Dryer model decreases by up to 3% when drain condensates.
ture of over 300˚C, protects the rotors from a decrease in per- The overhaul cost, which covers the most of maintenance cost, 5. Discharge air temperature with Dust Proof option or Simple Package Filter option is
Package R:Built-in Dryer (Without R:without dryer type)
Nominal A:Air-cooled, W:Water-cooled
formance (efficiency, air purity, etc.). is about half of two-stage for the same reason. ambient temperature + 18˚C or below. Output (kW) V:V-type (Without V:Fixed Speed type)
6. Earth leakage circuit breaker is NOT equipped within. Prepare it in advance.

1 2
Hitachi Original Oil-free Screw Technology – OIL FREE SCREW SINGLE STAGE(15/22/37/55kW)

Single-Stage Up to 0.7MPa PQ WIDEMODE (V type)


Instrumental Panel
Energy Saving from Various Combinations -type based Systems
Air capacity increases accordingly at PQ WIDEMODE ON.
Proposal for Energy-Saving
Capacity in PQ WIDEMODE PQ WIDEMODE is possible to switch between ON and OFF, responding
Air-End unit:m3/min Three proposal systems responding to various requirements
Discharge to customers’ requirements.
Pressure
For Energy-saving For Maximum Performance of Compressor
Combination V-type with fixed speed type achieves
Inverter MPa 0.4 0.5 0.6 0.7
PQ WIDEMODE [OFF] PQ WIDEMODE [ON]
Gear Case Model
Energy saving operation without Energy saving operation with Energy saving operation by more than
(%) (%)
100 100 PQ
Conventional WIDEMODE external controller external controller one V-type with multi-unit controller
22kW 4.3 4.0 3.7 3.4

Power Consumption Ratio (%)

Power Consumption Ratio (%)


Operation
75 75
Main Motor 0.7MPa
0.7MPa
Control Panel 50 50
37kW 6.4 6.0 5.5 5.0 0.6MPa
0.6MPa V-M Combination System Single-V System Multi-V System
25 25 0.5MPa
0.5MPa
Energy saving operation by one V-type Energy saving operation by one V-type Energy saving operation and
0.4MPa
0 (%) 0.4MPa 0 (%) and maximum two fixed speed type and more than one fixed speed type averaging V-type operating hour
55kW 8.2 7.6 7.0 6.4 0 20 40 60 80 100 0 20 40 60 80 100 109 119 128
Air Consumption Ratio (%) Air Consumption Ratio (%) with multi-unit controller.
1. When the operating pressure is reduced from 0.7MPa to 0.6MPa, the 1. When the operating pressure is reduced from 0.7MPa to 0.4MPa, the
Note: For dryer built-in model, minimum pressure is 0.5Mpa in Max power consumption is automatically reduced to approx. 92% of power consumption is reduced to approx. 79%.

*The above picture shows the internal structure


the PQ WIDEMODE. 0.7MPa. 2. With the excess power from depressurization, you can increase the air
Basic Example of V-M Combination System Following Energy-Saving effect can be
2. When the pressure is reduced to 0.5MPa, the power consumption capacity to 128%* of the rated one. At that time, the power consump-
of 55kW Air-Cooled model (V-type). reaches about 85%. When the pressure is reduced to 0.4MPa, the tion reaches 100%. achieved due to the V-M Combination
power consumption reaches about 79%. If you wish to use maximum performance under rated power consump-
(55kW × 2 units)
If you know your air consumption for sure and wish to achieve Energy- tion, PQ WIDEMODE [ON] is recommended. DSP-55AN×2 Energy-Saving of 73MWh/y can be achieved in case of air consumption at 150%.
Fixed Speed type 55kW with

Power Consumption Ratio (%)


Saving, PQ WIDEMODE [OFF] is recommended. * In case of 55kW
AUTO operation function Comparison of Annual Power Consumption
in case of Air Consumption at 150% Approx.
Premium Air Quality
73MWh

Annual Power Consumption (MWh/y)


800

Environment Response Energy-Saving


True Oil-free Air at Class 0 Level 600 Effect
Air purity class of the discharge air from Hitachi Oil-free Screw air compressor (DSP) is proved to be the ISO-8573-1 DSP-55VAN+55AN
Oil Mist Remover (OMR) and Auto Drain Valve Oil Mist Remover Auto Drain Solenoid 400 Calculation Condition:
highest level “Class 0” from the test result which was conducted by the renowned TÜV institute, in Valves for After-cooler ·8,000h/year operation
installed as Standard Equipment 200
accordance with ISO8573-1. ·Control pressure
55AN×2: 0.7MPa
Oil Mist Remover (OMR) and auto drain solenoid valves V-type 55kW Air Receiver Tank Air Consumption Ratio (%) 0 55VAN+55AN:0.6MPa
DSP-55AN DSP-55VAN
×2 +DSP-55AN
are equipped as standard. OMR can collect almost all oil
■ ISO8573-1:2010 CLASS 0 TÜV Certification fumes from the gear casing and recycle them.
TÜV (The Technische Überwachungs Verein), a Auto drain solenoid valves for condensate of both Single-V (Multi-V)
Germany based international test service provision inter-cooler and after-cooler minimize air consumption. Example of Multi-Unit Control System Multi-Roller EX 400
Explanation

Power Consumption Ratio (%)


third-party on aspects of technical safety and quality Multi-Roller EX + 300
V

evaluation, is globally well-reputed on its neutrality DSP     -type + S -type


Fixed Full load lock V
200 Always running, follow the fluctuation of air
and expertise as well as its strictness in testing. DSP Fixed Speed Models Speed consumption
Expanded Line-Up (Low Pressure) Fixed
Speed
Model
Start/Stop
100
V S S

Fixed Model Fixed speed type or -type


V S S S
Speed
0.3 MPa model is newly added Capacity Comparison Model 0 100 200 300 400
Full load or stop
-type *S indicates Fixed Speed Type.
Air Consumption Ratio (%)
Air capacity is improved by the 0.7 MPa Model 0.4 MPa Model 0.3 MPa Model
newly-developed high efficiency air-
end.
22kW 3.4 4.0 4.6
High Performance Air-End Cut Down Overhaul and Initial Cost
Stainless Steel Rotor 37kW 5.0 5.9 6.7
100 100
Air-End
Particular stainless steel,
which is superior in corrosion
50 50
55kW 6.4 8.0 8.5
resistance and durability, is (m3/min) ■ Application
applied for rotor with highly ● The compressor described in this catalog utilizes only air as a gas. Never use any gases other than air.
accurate grinding. Applications   This could result in a fire hazard or damage to the equipment.
0 0
Single-stage Two-stage Single-stage Two-stage Main Production Line ● Hitachi Compressors are not designed, intended or approved for Breathing Air Applications.
Furthermore, compensated In case that the pressure require-
Comparison of Comparison of
  Hitachi assumes no responsibility or liability for compressors used in breathing air applications.
profile, which is optimized for ment is higher than blower but lower ■ Installation
Overhaul Cost (%) Initial Cost (%)
thermal expansion during ● Install these compressors indoor. Environments susceptible to moisture such as precipitation or vapors should be avoided
than standard compressor SPEC,
Example of Hitachi 55kW (single-stage) and 45kW (2-stage), without dryer model
  — this could result in fire hazard, electric shock, rusting, or shortened life of parts.
operation, enables to keep low pressure SPEC DSP can be your ● There should be no explosives, flammable gas (acetylene, propane, etc.), organic solvent, explosive powder, or flame used near the
optimal clearance. solution. 0.7MPa SPEC   compressor — it may cause fire hazard.
Comparison of cost with the same air capacity level Low Pressure Equipment ● Avoid using the compressor at a place where there is corrosive gas such as ammonia, acid, salt sulfurous acid gas, etc.
High Performance Coating Because there is only one air end for DSP single-stage model,
Powder
  — this could result in rusting, shortened life, or damage to the equipment.

Hitachi original coating, which can withstand the high tempera- the initial cost is lower than two-stage model. ■ Usage
ture of over 300˚C, protects the rotors from a decrease in per- The overhaul cost, which covers the most of maintenance cost, ● Before use, be sure to read the instruction manual thoroughly for correct use of the compressor.
formance (efficiency, air purity, etc.). is about half of two-stage for the same reason. ● Do not modify the compressor or its components — this could result in damage or malfunction.
0.3MPa SPEC Air Blow Powder Transport
1 3 4