Вы находитесь на странице: 1из 4

ETM-WT Electronic Temperature Monitor

1. Description:

ETM-WT Electronic Temperature Monitor accepts


Pt100 RTD resistance input from sensor mounted on
transformer tank and indicates the Top Winding
temperature of the transformer. Winding Temperature
of the oil-immersed transformers is calculated from
temperature gradient based on CT Secondary current
corresponding to the load current and the top oil
temperature. The CT secondary current, temperature
gradient and thermal time constant settings are all user
configurable. ETM also has 2 or 4 SPDT relay contact
outputs for winding temperature. Optionally, analog
4-20mA dc outputs and RS 485 ports can also be
provided. ETM has a simple user friendly front panel
configuration. ETM is field mountable with a rugged
IP55 water proof enclosure.

2. Features:

♦ Simple user friendly front panel configuration


♦ Input : Pt 100 RTD, 3 Wire
♦ 2 or 4 SPDT relay contact outputs for winding temperature
♦ User selectable Alarm / Trip /Fan settings
♦ The CT secondary current, temperature gradient and thermal time constant settings are all user
configurable
♦ 4 – 20mA Analog o/p for Remote indication (Optional)
♦ RS 485 Digital communications port (Optional)
♦ A GREEN LED Indicates that Instrument in program mode.
♦ A YELLOW LED indicates the Maximum Temperature of WTI
♦ RED LED indication for the ALARM, TRIP FAN1 or FAN2 ON
♦ Operates a relay with a SPDT contact when the inputs exceed the setting.
♦ If a RTD goes open circuit, it is detected, the displays “OPEN”. A failed RTD will not cause TRIP.
• Universal Power Supply 90-260V AC/DC
• Field Mountable IP55 Enclosure

3. Technical Specification

General Specification
Input PT 100 RTD (3 wire) (single i/p)
CT Sec Current Input 1.0A – 5.0A (User selectable) To be specified on order
Temperature Gradient 1°C – 45°C (User selectable) To be specified on order
Thermal Time Constant 1 to 60 minutes user settable
CT Overload Condition 300% for 1 min and 150% continuous
No. of set points 2 or 4 for WTI (Alarm, Trip, FAN1 & FAN2)

1
ETM-WT-D-001-01
ETM-WT Electronic Temperature Monitor

Range 0-1500C (other range on order)


Resolution 0.1°C
Accuracy ±1°C
Display 4 Digit Seven Segment LEDs (Red Colour)
Max Recording Maximum Temperature Recording with in steps of 20C
Electrical Specification
Power Supply 90-260V, ac/dc
Insulation Resistance ≥20MΩ Between Earth to all terminal when measured with 500 V DC
Insulation tester
Isolation 2500V, rms, AC between Power Supply terminal and all other terminal for
60 Secs
Warm Up time 15 minutes (Min)
Current Outputs 4-20mA dc Analog output (4-20mA suitable for 500Ω burden).
Relay contact Current 5A at 220V AC Res. Load or 1A at 220V DC
Rating
Digital Communication RS 485
Protocol Supported: MODBUS RTU
Terminals Screwed Caged suitable for one 2.5 Sq.mm wire
INDICATIONS 4 No Red LEDs to indicate- WTI Alarm
WTI Trip
WTI FAN1
WTI FAN2
2 No Yellow LEDs to indicate- Controller is in gradient mode
Controller is in maximum mode
1 No Green LEDs to indicate - Controller is in program mode
Mechanical Specification
Overall Dimensions 225x185x115 mm
Mounting Wall mounting with Anti-vibration pads and M6 screws.
Weight 3 Kgs appx without packing
Enclosure Water proof enclosure with acrylic viewing window.
Panel Protection Level IP 55
Ambient Temperature 0~500C 45~80% RH

USER CONFIGURATION

The 4 Front panel keys – PRG, INC, R/SHIFT, MAX are used to change the settings manually.
♦ Set values of WTI Alarm, Trip, FAN1 & FAN2.
♦ Differential setting of the Relays for the above.
♦ Winding Temperature Gradient Settings.
• CT Secondary current.
• Winding Temperature Rise.
• Thermal time constant.

2
ETM-WT-D-001-01
ETM-WT Electronic Temperature Monitor

SETTING LIMITS & DEFAULT SETTINGS:


SETTING LIMITS DEFAULT FACTORY
SETTINGS
WTI ALARM RELAY Set point : 0-149°C Set point : 90°C
WTI ALARM DIFFERENTIAL Differential : 0-99°C Differential : 10°C
WTI TRIP RELAY Set point : 0-149°C Set point : 100°C
WTI TRIP DIFFERENTIAL Differential : 0-99°C Differential : 5°C
WTI CT CURRENT 1.0A TO 5.0A CT Current :1.4A
WTI GRADIENT/TEMP.RISE 1°C TO 50°C Temp Rise : 15°C
WTI THERMAL TIME CONSTANT 1 min TO 60 min TIME : 5 min
WTI FAN1 RELAY Set point : 0-149°C Set point : 110°C
WTI FAN1 DIFFERENTIAL Differential : 0-99°C Differential : 5°C
WTI FAN2 RELAY Set point : 0-149°C Set point : 120°C
WTI FAN2 DIFFERENTIAL Differential : 0-99°C Differential : 5°C

ORDER FORM

ETM-WT

Display Range Communication


015 : 0 to 150°C N: No Digital Communication
315 : 30 to 150°C 4: RS 485
214 : 20 to 140°C 2: RS 232
Other range on special
order

Display Type Output


0 - WTI without any Relay output 0 : No Analog output
2 – WTI with 2 Relay output 1: 4-20mA dc analog output
4 – WTI with 4 Relay output