Technical data

Mechanical life Contact blocks (cont.)


Operators Micro switch block
Pushbuttons with flush or extended Ratings as per IEC 60 947-5-1
Mechanical life, selector switch
button, momentary mushroom push- Rated insulation voltage, Ui 125 V
button 2 million operations Rated thermal current, Ith 3 A
Present standard
Selector switch
(no operating of
Rated operational current, Ie
center contact) 500 000 utilisation category AC 14, at 125 V 0.5 A
Present standard (no
operation of center 500 000 operations Rated operational current, Ie
utilization category DC 13, at 24 V 0.3 A
contact)
250 000
Rated operational current, Ie
utilization category DC 12, at 24 V 0.1 A
Minimum switching capacity 3 V DC 1 mA
With operating
of center contact Ratings as per UL 508
With operation of center 250 000 operations
250 000 3 A, 125 V AC
contact
0.1 A, 48 V DC
0.2 A, 60 V DC
150 000 operations
150 000
Contact resistance < 25 mΩ

Maintained mushroom Compulsory function test at 5V, 16 mA


pushbutton, key operated selector Max. number of contact blocks per operator
switch and double pushbutton 500 000 operations
The contact blocks can be stacked in max
Emergency stop pushbutton 100 000 operations two levels on the 3- block holder.
Toggle switch 1 million operations Only one level is accepted on the 5-block
holder.
Temperature Pushbutton, toggle switch and mush-
Ambient temperature during operation -25 to +70 °C room pushbutton 6
Maintained pushbutton 6
Storage temperature -40 to +85 °C Double pushbutton, selector switch,
key operated selector switch and
Terminals Make-and-break
emergency stop pushbutton 6 contact
Plus-minus Pozidriv No.2 screw with DIN-washer.
Short circuit protection
Connectable area min. 1 x 0.5 mm2/AWG 20
Max. fuse at 1 kA Modular pushbutton
10 A delayed
max. 2 x 2.5 mm2/2 x AWG14
Compact pushbutton Compact emergency
Recommended torque 0.9 Nm Diagram for make-and-break contact

Tightening torque NC
NC -1 -2 -1 -2
Locking nut, M22 Min. 2 Nm
Max. 2.3 Nm
NO -3 -4 NO -3 -4

Contact blocks = Closed contact = Clos


Mechanical endurance 10 million operations
Self cleaning contacts of silver, NC contact with positive opening.
At voltages and currents below 24 V and 5.6 mA two contact blocks in
parallel are recommended or micro switch block. As an alternative, gold
plated contacts can be used.
Ratings as per UL, CSA, NEMA A600 Q600
AC DC
Rated insulation voltage 600 V 600 V
Rated thermal current 10 A 2.5 A
Rated operational current at 120 V 6 A at 125 V 0.55 A
240 V 3 A 250 V 0.27 A
480 V 1.5 A 480 V 0.10 A
600 V 1.2 A 600 V 0.10 A
Ratings as per IEC 60 947-5-1
Rated insulation voltage, Ui 690 V
Rated thermal current, Ith 10 A
Rated operational current, Ie
utilisation category AC 15, at 120 V 8 A
230 V 6 A
400 V 4 A
690 V 2 A
Rated operational current, Ie
utilisation category DC 13, at 24 V 5 A
125 V 1.1 A
250 V 0.55 A

40
1SFC151003C0201