Академический Документы
Профессиональный Документы
Культура Документы
HST
SV
Hydraulic components
for strip guiding
long life-time
high reliability
huge performance
range
Hydraulic control HR/HA
Hydraulic strip guiding system: Customer benefits of HR/HA:
The hydraulic control unit HR and the hydraulic power hydraulic energy for any power range
unit HA reliably generate hydraulic energy for any power units can be tailor-made for coilers
power range. A hydraulic control unit HR is a hydraulic that require extreme capacities
power unit HA with a proportional valve that controls
high level of reliability in all areas of
the volume flow of the fluid. application
monitoring device (level, temperature,
For strip guiding systems, hydraulic power units with a
pressure) integrated
rating of between 0.55 and 18.5 kW are normally used.
protection of the components from conta-
minants in the hydraulic oil via special filters
Standard hydraulic power units basically consist of an
is guaranteed
oil tank, a motor/pump assembly and a filter. Pressure-
regulated pumps with variable flow rates are used. customer specific design and optimization
Via the internal lines of the pilot valve the piston slide
valve is pushed with pressure against the spring force. By
control
this the hydraulic fluid is led to the operating lines A or lines
B. The inductive position transducer meanwhile monitors
position main valve
the position of the main control piston. The volume flow is
transducer
determined by the position of the piston slide valve and is
piston
proportional to the input current of the control amplifier. spring
The piston is held in the middle position by two pressure
springs, e. g. in case of power breakdown. piston front face control
channels
Servo valve SV2-16 (double-stage)
ent servo valve SV
Technical features — servo valve: Customer benefits — servo valve:
temperature- and pressure-independent zero cleaning flush of the valve during operation
point stability
also suitable for low pressure levels
practically constant dynamics (almost
single- and double-stage construction possible
independent of pressure and drive)
(SV1-.../SV2-...)
large control distances, long service life,
guaranteed minimum friction losses
low leakage flow
mechanical manual/emergency control and high repetition accuracy
external performance monitoring huge range of performance for single- and
spring-centred rotary slide (zero position in the double-stage valves
event of an electrical power failure) high level of reliability
standard connections, standard plug extremely easy to service
Q02(p) 5
F 0 0 ϕ
Q02(100 bar)
dB o
F 4
Q 100 -10 -40
I/min 80
SV 1 - 10/48
60
SV 1 - 10/32 -20 -80 3
40
SV 1 - 10/16
20 -30 -120
2
SV 1 - 10/8
10 -40 -160
SV 1 - 10/4
8
6 1
4 -50 -200
2 -60 -240
100 200 300
1 pS
5 6 7 8 9 10 20 50 100 150 f
0 20 50 70 100 150 200 250 300 bar
pv Hz
bar
Relationship of flow rate to valve Frequency response pS = 200 bar Relationship of leakage flow rate to
pressure drop at rated motion I / IN = 10 % ; 30 % ; 100 % operating pressure
100 100
Q p 1% 6%
% %
80 80 0
F 0 ϕ
dB o
60 60 F
-10 -40
6%
40 40
1% -20 -80
20 20
-30 -120
-60 -60
-60 -240
-80 -80
5 6 7 8 9 10 20 50 100 150 f
-100 Hz
-100
Group
.moving ahead.