Академический Документы
Профессиональный Документы
Культура Документы
com
Issued: 2016
Contents
Swabable Valves 3
Male Luer Valves 11
Luer Activated Valves 13
Luer Lock Access Valves 15
One-Way Check Valves 17
Pressure-Activated/Relief Valves 19
Tubing Clamps 21
Hand Pumps & Fittings 23
Closures & Tube End Drain Valves 24
Flanges 24
Transfer Valve 25
A History of Innovation
Halkey-Roberts is a global leader
in the design and manufacture of
valves for medical device
companies whose products
require precise delivery of fluids
and gases.
Since 1941, Halkey-Roberts has focused innovation in the
production of products to the highest quality standards. Our
success in molding and high speed assembly of thermoplastics
and silicones is rooted in our unwavering commitment to our
customers, end-users, and employees. We constantly invest in our
people, infrastructure, and technologies and every product we
make is supported by R&D, Materials, Manufacturing, and Quality,
Engineers. Every customer is supported by a responsive customer
service team that is thoroughly educated about our products. Our
state-of-the-art facility in St. Petersburg, Florida, USA, is outfitted
with the very best equipment, and is staffed by highly trained
associates. Our total dedication to what we do enables us to
produce valves that far exceed Six Sigma quality standards, and
makes us the choice of major medical device companies around
the world.
Images herein are not to scale. For technical information and drawings,
terms and conditions, product disclaimers and patent information, please
visit our website: www.halkeyroberts.com
1
a. b. c.
d. e. f.
g. h. i.
j. k. l.
m. n. o.
2 p. q. r.
Swabable Valves
A comprehensive line of high flow, split septum
swabable valves for infection control and the
elimination of needles.
The unique and innovative patented design allows the valve
to be used in a wide variety of demanding applications where
high flow and a closed system is a must.
The valves are DEHP free, made with ISO-10993 materials, and
not made with natural rubber latex. Bodies are available in BPA-free
materials and polycarbonate.
The valves mate securely with standard ISO-594 compliant
syringes and connectors.
Swabable Products
Part No. Description
a. 245204 series Straight
b. 2456 series Y-port
c. 2455 series Tube End
d. 245501024 Bondable valve
e. 24542 series T-Port
f. 2454 series Small-Bore T-Port
g 245110024 Bag valve
h. 24511 series Break-off valve
i. 2455 series Barb Valves
j. 245700021 20 mm vial cap
k. 245720021 13 mm vial cap
l. 245680024 Build-In Assembly
m. 245814024 Hi-Flo Lever Handle Stopcock
n. 245824024 Hi-Flo T-Handle Stopcock
o. 245834024W Standard Lever Handle Stopcock
p. 245844024B Standard T-Handle Stopcock
q. 245854024W Standard Lever Bondable Stopcock
r. 245800912 Multiport Manifold
Performance Characteristics
245204024 polycarbonate
245204050 BPA-free copolyester Priming Volume: 0.09 ml
Performance Characteristics
Priming Volume: 0.19 ml
245624024 polycarbonate
0.160 inch ID (4.01 mm) Flow Rate Averages**
245624050 BPA-free copolyester 1 psi: 410 ml/minute
0.160 inch ID (4.01 mm)
3 psi: 710 ml/minute
245634024 polycarbonate
0.142 inch ID (3.6 mm) 5 psi: 930 ml/minute
Available in five sizes with clear or red 2.0, 2.5, 2.8, 3.0 mm = 0.12 ml
caps. 3.7 mm = 0.22 ml
4.1 mm = 0.24 ml
Bondable Valves
Designed to bond to either
4 mm I.D. tubing or open Performance Characteristics
luer connectors. Priming Volume
(without tubing): < 0.13 ml
Performance Characteristics
245424024 6.6 mm T-Port Priming Volume: <0.15 ml
Small-Bore T-Ports
Can be bonded in line on tubing sets
to provide an access port for taking
samples or injecting medication.
Performance Characteristics
Priming Volume: <0.15 ml
Performance Characteristics
245504024 1/4 inch Barb Priming Volume: 0.30 ml
245516024 3/16 inch Barb
Performance Characteristics
245720021 13 mm cap Priming Volume: 0.06 ml
Performance Characteristics
Priming Volume (without tubing)
Manifold Only = 1.4 ml
8
Stopcocks Our low profile series stopcocks offer
the safety of a closed system with the
versatility of a 4-way stopcock.
They enhance infection control and
help to prevent accidental blood loss
or leakage.
245824024 ‘T’ Handle ‘Hi-Flo’
245814024 Lever ‘Hi-Flo’ Performance Characteristics
Priming Volume: <0.35 ml
Performance Characteristics
Priming Volume: < 0.2 mL
9
a. b.
work in progress
c. d.
10
Male Luer Valves
Our Male Luer Valves (MLV) are ideal for flushing
and drainage applications, IV solutions and
home healthcare.
a. c.
d. e.
12
Luer Activated Valves
Our syringe check valves are designed to fill, hold
and release controlled amounts of fluids and gases
on demand.
They are used on endotracheal tubes, tracheostomy tubes,
and gastric and urethral catheters for balloon inflation and
deflation and specialized balloon catheter applications.
The valve stem and body mate securely with all standard
luer syringes.
a.
d.
c.
e.
f.
g.
Luer Lock Access Valves
As replacements for needle ports, this
comprehensive line of needlefree access
sites can be used for drug delivery/IV
administration applications.
They can also be used on a variety of balloon catheters
such as endotrachael tubes, tracheostomy tubes, gastric
feeding tubes as well as urethral catheters.
All materials are USP Class VI and not made with natural
rubber latex.
c. d.
e.
16
One-Way Check Valves
Designed as dependable, in-line check valves or
directional flow control valves for liquid and air.
For maximum flexibility, the valve stem and body mate
securely with all standard luer syringes and various
tubing sizes.
All materials are USP Class VI and not made with natural
rubber latex.
c. d.
e. f.
g. h.
18
Pressure-Activated/Relief Valves
Designed to hold and release gases and/or fluids at
predetermined pressures automatically.
The relief valves are used for a variety of purposes including
tube-end and in-line pressure control, over or under pressure
control, and IV drug delivery.
All plastic materials are USP Class VI and not made with
natural rubber latex.
d. e.
f. g.
20 h.
Tubing Clamps
Halkey-Roberts invented the precision plastic
tubing clamp almost 50 years ago. Although
widely copied, no company can match our
expertise. Our clamps are designed for both
standard and specialized applications.
Available in open/closed single position and multi-position
models with fine or coarse teeth adjustment, they provide one
hand control from totally open through gradual occlusion, to
completely closed.
The clamps are precision molded in a variety of materials
to maximize effectiveness to suit your sterilization needs.
Assorted colors are available. Please visit our website for
additional information.
a.
f.
g.
b.
h.
c. i.
j.
d.
22 Images not to scale.
Hand Pumps and Fittings
Molded from materials not made with natural
rubber latex, our hand pumps are designed for
fast response and comfort.
Our pumps are available with a wide variety of end fittings
and check valves.
Unlike others, our pumps are designed for user comfort and
are found on a wide variety of infusion cuffs, blood pressure
cuffs, air bladders, air cushions, and air sampling devices.
Flanges
Typically used to connect tubing to drainage, collection sets and
inflatable cushions and mattresses.
167 series
24
Transfer Valve
The swabable transfer valve is ideal for stem
cell, biopharmaceutical and drainage
applications involving large volumes and/or
viscous substances.
The transfer valve can be accessed with a standard
catheter-tipped syringe.
Available with a polycarbonate body and silicone stem,
the valve is made from ISO-10993 compliant, DEHP-free
materials and not made with natural rubber latex.
255004024
transfer valve
+1 727.471.4200
sales@halkeyroberts.com
www.halkeyroberts.com
©2016 HR®