Вы находитесь на странице: 1из 2

9900V

MICROCODE VERSION 21-14-31-00/00


RELEASED 12/07/06
Newly supported features and functions for Version 21-14-31-00/00

1. Mainframe & OPEN System


None

2. Mainframe System
None

3. Open System

3-1 System Option Mode 346 for LUN Security Function


Description When the subsystem was connected with an HBA containing HP WWN*1, the LUN Security was
not operational unless the host mode was set to 03. System option mode 346 added to enable the
LUN Security function without host mode setting restriction.

System option mode 346 ON:


LUN Security is operational without host mode setting restriction.

System option mode 346 OFF:


LUN Security is operational only when host mode 03 is set to ON.

*1: The WWN contained in the HBA below:


- The HBA installed on the HP Integrity server for Windows/Linux use
(no problem when the HP-UX host mode is set for the HP-UX connection)
- The HBA installed on the HP Blade server
Changed Part DKCMAIN

HDS Confidential 1of 2


The change of contents for Version 21-14-31-00/00

1 Pairs with Duplicate MU# Created Invalidly


Contents Unable to delete pairs after creating Shadow Image, Cruise Control and Hi-Copy pairs with
duplicate MU numbers. Micro-program modified so that the duplicate pairs are not created.
Conditions The problem occurs with all conditions met.
- Create the following Shadow Image pairs simultaneously
P-VOL=VOL#a MU#=A, S-VOL=VOL#b and P-VOL=VOL#a MU#=A, S-VOL=VOL#c
- The problem does not occur in case of LUSE VOL
Category Shadow Image
Changed DKCMAIN

2 CQUERY ABEND after Installing APAR OA14852


Contents After installing APAR OA14852, the CQUERY command of GDPS ended abnormally
(SSB=747B F/M=04).
Conditions The problem occurs when all the conditions are met.
1. True Copy – S/390 pair
2. Install APAR OA14852
3. After #2, issue the CQUERY command from the GDPS environment
Category True Copy – S/390
Changed DKCMAIN

3 WCHK1 at all FICON PCBs


Contents WCHK1 occurred at all FICON PCBs during a Write command processing for a TC390 Async
pair.
Micro-program modified as follows.
1. The WCHK1 is prevented
2. SSB=0x6cc0 or SSB=0x6cc1 is reported for information enhancement
Conditions The problem occurs when all the conditions are met.
1. True Copy – S/390 Async
2. A reset occurs during a Write command processing
3. An invalid processing occurs
Category True Copy – S/390 Async
Changed DKCMAIN

HDS Confidential 2of 2

Вам также может понравиться