Katie Lazarus-Born IIT Calibration IIT Calibration is made up of the following calibration features. White Reference CCD Calibration – Reflection Ratio and B* Calibration Coefficients Optical Axis Calibration • This routine should only be run after replacing a CCD Lens Assembly, Xenon Lamp, IIT /IPS PWB, or if directed by the service documentation • RUNNING THIS ROUTINE WITH INCORRECT PAPER, OR AN INCORRECT OR DIRTY/DAMAGED TEST PATTERM CAN ADVERSLY AFFECT IMAGE QUALITY
Xerox Internal Use Only
IIT Calibration
Xerox Internal Use Only
White Reference White Reference values should be 135 + 5 bits White Reference Things to do, check if these readings are off • Make sure NVM location 715-106 (paper code) is set to 5 for XC (Digital Color Xpressions+) or 6 for XE (Color Value Tech+). • Make sure you use 10 sheets of 11X17 Color Expressions + Red 136 98 brightness paper to perform the setup. Kit # (128E1460) • Clean both sides of the Document Glass, Document Cover, Green 137 White Reference Strip, Reflector, and Mirror. • Clean the Exposure Lamp with a clean cloth and Film Blue 141 Remover. • Clean the Lens with Lens and Mirror Cleaner and lint free cloth. • Replace the Xenon lamp. Lamp ballast PWB, IIT/IPS PWB, and CCD Lens Assembly Note: If White Reference numbers are off and you do not have color expressions 98 media input the values on the manufacturing sheets in tray 1 for 715-092 through 715- 094
Xerox Internal Use Only
CCD Calibration b* Calibration – the Patch Measurement should b* Calibration be within + 10 bits of the Standard Value Things to do, check if judgment fails PCON SCAN • Make sure you have the correct test pattern (82E13120) and it is clean and free of defects. Correction Coefficient 3 3 • Make sure the test pattern is positioned with the L.E. toward the left of the platen glass. b* Patch Measurement 225 211 • Clean both sides of the Document Glass, Value Document Cover, White Reference Strip, Reflector, and Mirror. b* Standard Value 225 225 • Clean the Exposure Lamp with a clean cloth and Film Remover. Result OK OK • Clean the Lens with Lens and Mirror Cleaner and lint free cloth. • Replace the Xenon lamp. Lamp ballast PWB, IIT/IPS PWB, and CCD Lens Assembly If the standard value is 0 and the judgment fails go to NVM locations 715-260 and 715-266 and set them both to 225
Xerox Internal Use Only
CCD Calibration Reflection Ratio
R G B Y 73 107 215
M 136 227 208
C 230 171 101
K 242 242 243
Result ok
• CCD Calibration – Uses the standard test pattern
82E13120 to calibrate the sensitivity of the CCD. It looks at the 5 squares in the upper center of the test pattern as a reference to do the calibration. • Highlighted squares in the above table should be 200 or higher • Yellow subtracts Blue (blue 200 or higher) • Magenta subtracts green (green 200 or higher) • Cyan subtracts red (red 200 or higher)
Xerox Internal Use Only
CCD Calibration Things to do, check if these readings are off Make sure you have the correct test pattern (82E13120) and it is clean and free of defects. Make sure the test pattern is positioned with the L.E. toward the left of the platen glass. Clean both sides of the Document Glass, Document Cover, White Reference Strip, Reflector, and Mirror. Clean the Exposure Lamp with a clean cloth and Film Remover. Clean the Lens with Lens and Mirror Cleaner and lint free cloth. If problem remains try replacing the Xenon lamp. Lamp ballast PWB, IIT/IPS PWB, and CCD Lens Assembly
Xerox Internal Use Only
Optical Axis Optical Axis Correction The purpose of this adjustment is to align the CCD with the Lens. This Result ok procedure should only be performed if the Lens or CCD is replaced, or if Front Nut Correction angle -15 the documentation specifically directs. Rear Nut Correction angle -15 Follow your Service Documentation Adjustment 6.1 to complete this adjustment.