Вы находитесь на странице: 1из 8

CRANE 10 TONNE CAPACITY

CRANE BEAM SPLICE CONNECTION CALCULATION

Beam : WF450x200x9x14 (with additional cap plate 20 mm)

Bolt A 325
3
fy = 635 Mpa (Yield Stress) Sx = 1618353 mm
σ = 423.33 Mpa
τ = 140 Mpa (allowable shear stress) M = fy x Sx = 388404720 Nmm
N
σ tu = 444 Mpa (allowable bearing stress) Q = 0.4 x tw x (d-2tf) ##
σ ta = 381 Mpa (allowable tension) N = ##

Actual Loads
Q = 826393 N (Actual shear Load)
N = 0N (Actual axial load)

Try bolt (D) M 25


numb of bolt (n) = 14
Check for shear

Ag = 1/4 π D2 = 490.8594 mm
2
(cross section area of bolt)
τ = P / n Ag
= 120.2584 Mpa < τ OK! 1

Beam : WF450x200x9x14 (with additional cap plate 20 mm)

Bolt A 325
fy = 635 Mpa (Yield Stress) M = #
σ = 423.33 Mpa Q = 0.4 x tw x (d-2tf) = 364608 N
τ = 140 Mpa (allowable shear stress) N = #
σ tu = 444 Mpa (allowable bearing stress)
σ ta = 381 Mpa (allowable tension)

Actual Loads
Q = 364608 N (Actual shear Load)
N = 0N (Actual axial load)

Try bolt (D) M 25


numb of bolt (n) = 6

Check for shear


Ag = 1/4 π D2 = 490.8594 mm
2
(cross section area of bolt)
τ = P / n Ag
= 123.8031 Mpa < τ OK! 1
DEMAG DRAWING

The number and diameter of


bolts is not adequate

Please use the number and diameter of bolts as follow

A325 14M-25

A325 6M-25
PILE BEARING CAPACITY CALCULATION

Maximum reaction from upper steel structure based on service load combinations is in the table
below.

Hence the pile reaction is in the table below

Below is the calculation for bored pile foundation using Reese and Wright Method

BORED PILE BEARING CALCULATION - REESE & WRIGHT, 1977

BH : 1
Diameter (B) : 0.35 m SF Skin friction 3
Perimeter (p) : 1.100 m SF End bearing 3
Area (Ap) : 0.096 m2
Inertia (I) : 0.001 m4

cu φ qp fs Fs Qp Qult Qall
Kedalaman (m) Soil N-SPT
(kPa) (kPa) (kPa) (kN) (kN) (kN) (ton)
Data NSPT
0 1 Clay 13 78 702 42.9 47.17 67.51 114.68 3.82
1 3 Clay 14 84 756 46.2 148.77 72.70 221.47 7.38
3 5.1 Clay 22 132 1188 72.6 316.41 114.24 430.65 14.35
5.1 8 Sand 19 30 1092.5 36.80 433.75 105.06 538.81 17.96
8 10 Clay 35 210 1890 115.5 687.75 181.75 869.50 28.98

Data CPT
0 1 Clay 3 18 162 9.9 10.89 15.58 26.46 0.88
1 3 Clay 8 48 432 26.4 68.94 41.54 110.48 3.68
3 5.1 Clay 14 84 756 46.2 175.62 72.70 248.32 8.28
5.1 8 Sand 12 30 690 36.80 292.97 66.35 359.32 11.98
8 10 Clay 35 210 1890 115.5 546.97 181.75 728.71 24.29

Average Qall 26.64 ton

Up Lift Resistance 14.58574 ton


Efficiency factor 0.88
Qall 23.44044 ton
Below is the pile lateral capacity calculated with L Pile

The pile lateral capacity is 15 ton

Based on the pile reaction and pile bearing calculation, the summary is as follows :

1. The pile bearing capacity = 23 ton > pile reaction = 20.2 ton
2. The pile uplift capacity = 14 ton > pile reaction = 6.4 ton
3. The pile lateral capacity = 15 ton > pile reaction 1.3 ton

Please revise the pile design as follow:

160 D13-150

Bored pile
350 350 mm
600
350 D16-150

350

350 900 350 1000 D10-100


spiral

L= 10000
6 D13

D10-100 spiral
CRANE 5 TONNE CAPACITY

CRANE BEAM SPLICE CONNECTION CALCULATION

Beam : WF450x200x8x13 (with additional cap plate 20 mm)

Bolt A 325
3
fy = 635 Mpa (Yield Stress) Sx = 1295318 mm
σ = 423.33 Mpa
τ = 140 Mpa (allowable shear stress) M = fy x Sx = 310876320 Nmm
N
σ tu = 444 Mpa (allowable bearing stress) Q = 0.4 x tw x (d-2tf) ##
σ ta = 381 Mpa (allowable tension) N = ##

Actual Loads
Q = 740181.7 N (Actual shear Load)
N = 0N (Actual axial load)

Try bolt (D) M 25


numb of bolt (n) = 12
Check for shear

Ag = 1/4 π D2 = 490.8594 mm
2
(cross section area of bolt)
τ = P / n Ag
= 125.6649 Mpa < τ OK! 1

Beam : WF450x200x8x13 (with additional cap plate 20 mm)

Bolt A 325
fy = 635 Mpa (Yield Stress) M = #
σ = 423.33 Mpa Q = 0.4 x tw x (d-2tf) = 323136 N
τ = 140 Mpa (allowable shear stress) N = #
σ tu = 444 Mpa (allowable bearing stress)
σ ta = 381 Mpa (allowable tension)

Actual Loads
Q = 323136 N (Actual shear Load)
N = 0N (Actual axial load)

Try bolt (D) M 25


numb of bolt (n) = 6

Check for shear


Ag = 1/4 π D2 = 490.8594 mm
2
(cross section area of bolt)
τ = P / n Ag
= 109.7213 Mpa < τ OK! 1
The number and diameter of
bolts is not adequate

Please use the number and diameter of bolts as follow


PILE BEARING CAPACITY CALCULATION

Maximum reaction from upper steel structure based on service load combinations is in the table
below.

Hence the pile reaction is in the table below

Below is the calculation for bored pile foundation using Reese and Wright Method
Below is the pile lateral capacity calculated with L Pile

The pile lateral capacity is 15 ton

Based on the pile reaction and pile bearing calculation, the summary is as follows :

1. The pile bearing capacity = 9.9 ton > pile reaction = 8.8 ton
2. The pile uplift capacity = 6 ton > pile reaction = 0.5 ton
3. The pile lateral capacity = 15 ton > pile reaction 0.28 ton

Please revise the pile design as follow:

160 D13-150

Bored pile
350 350 mm
600
350 D16-150

350

350 900 350 1000 D10-100


spiral

L= 6000
6 D13

D10-100 spiral