Вы находитесь на странице: 1из 40

2016

THE YEAR OF
ALL FLASH

Технологический обзор
1
Архитектура

UNISPHERE

Эффективность & DATA


SERVICES

Файловая система

Защита данных

Виртуализация & UNITY VSA


2
EMC UNITY
TM

ALL FLASH HYBRID

ALL FLASH
DESIGN

Просто Гибко
SLICK UX  CLOUDIQ™ VIRTUAL & PURPOSE-BUILT & CONVERGED
PROACTIVE ASSIST UNIFIED NAS & SAN & VVOLS

Современно Доступно
ALL FLASH DESIGN WITH
INTEGRATED COPY DATA MGMT

3
MID-RANGE PORTFOLIO
VNX8000

CLOUD MANAGEMENT, TIERING, & ANALYTICS


VNX7600
Unity 600
(1000** drives/5PB ***cap)

VNX5800
S Unity 500
C
(500* drives/3.5PB*** cap)

VNX5600
A Unity 400
L
(250 drives/2.5PB cap)

VNX5400
E Unity 300
(150 drives/1.5PB cap)
VNX5200
UnityVSA
(up to 50TB cap)
ONE Architecture VNXe3200
ONE Interface
One Platform VNXe1600

SERVICE LEVELS
*350 drives available at initial release. 500 drive support will come within a year.
**500 drives available at initial release. 1000 drive support will come within a year.
***Maximum raw capacity will vary based on drive sizes available at time of purchase.

4
POWERFUL, SIMPLE HARDWARE
Before & After (VNX5800 to UNITY 600F)

BEFORE AFTER IMPROVEMENT


FORM FACTOR 7U 2U 71%
CABLES 30 6 80%
POWER CONSUMPTION 1495W 703W 53%
RACK INSTALL 60 min 2 min 97%
PERFORMANCE 101K 295K 3X

Test Profile: Thin LUN, Small Block Random Workload (8KB, 80/20 R:W, All SSD)

UNITY 600F
VNX5800

5
UNITY FAMILY
Flexible Deployment Options
UNITY 600F UNITY 600

UNITY 500F UNITY 500

UNITY 400F UNITY 400

UNITY 300F UNITY 300

ALL FLASH HYBRID


VIRTUAL & CONVERGED

6
THE UNITY OE
Новая архитектура

Protocol End Points

Replication
VMDK/VHD

Unified Svcs
Block File System VVOLs
(Thick/Thin LUNs) (64-bit)

Unified SUSE
Control Unified Pool based
Path

Multi-Core Architecture
• Cache
• FAST Cache
• RAID

Back End

7
UNITY HYBRID ARRAY MAXIMUMS
CPU, Memory, Capacity, Ports
Unity 300 Unity 400 Unity 500 Unity 600
2 x Intel 6- 2 x Intel 8- 2 x Intel 10- 2 x Intel 12-
CPU
core, 1.6GHz core, 2.4GHz core, 2.6GHz core, 2.5GHz
System Memory 48 GB 96 GB 128 GB 256 GB
Min/Max Drive Count supported 5/150 5/250 5/500* 5/1000**
Max Raw Storage Capacity supported*** 1.5 PBs 2.5 PBs 3.5 PBs 5.0 PBs
Max FAST Cache 800 GB 1.2 TBs 3.2 TBs 6 TBs
Max FE (front end) Ports per Array (all
24 24 24 24
types)
Max Initiators 1,024 2,048 2,048 4,096
4 x 4 lane 12Gb/s 4 x 4 lane 12Gb/s 4 x 4 lane 12Gb/s SAS 4 x 4 lane 12Gb/s
Embedded SAS IO Ports per Array, for
SAS ports SAS ports ports SAS ports
back end (BE) connectivity
Optional SAS IO ports per Array, for back NA NA
8 x 4 lane 12Gb/s SAS 8 x 4 lane 12Gb/s
end (BE) connectivity ports SAS ports

*350 drives available at initial release. 500 drive support will come within a year.
**500 drives available at initial release. 1000 drive support will come within a year.
***Maximum raw capacity will vary based on drive sizes available at time of purchase.
8
UNITY PROCESSOR ENCLOSURE (DPE)
Simple and Compact Design
12Gb SAS BUILT-IN BUILT-IN 16/8/4Gb FC
BACKEND 10GbT IP PORTS OR 10GbE IP OPTICAL PORTS
(2 PER SP) (2 PER SP) (2 PER SP)

2U

OPTIONAL MANAGEMENT
IO MODULES AND SERVICE PORTS
IO MODULE

(2 PER SP) (1+1 PER SP)


CHOICES

12Gb SAS BE (4-PORT) | 16/8/4Gb FC (4-PORT) |


1GbT IP (4-PORT) | 10GbT IP (4-PORT) |
10GbE IP OPT (2-PORT) | 10GbE IP OPT (4-PORT)

9
UNITY SLIC SUPPORT
• Available add-on SLIC options:
– 16Gb Fibre Channel frontend (4-port)
– 1GbE BaseT frontend (4-port)
– 10G BaseT frontend (4-port)
– 10GbE Optical (2-port)
– 10GbE Optical (4-port)
– 12Gb SAS backend (4-port)

10
DISK PROCESSOR ENCLOSURE (DPE)
UNITY CHASSIS – FRONT VIEWS

2.5”

3.5”

UNITY CHASSIS – REAR VIEWS

SPB

SPA

11
DRIVE ARRAY ENCLOSURES (DAEs)

2U 25 drive
2.5” enclosure

3U 15 drive
3.5” enclosure

12
UNITY DRIVE SUPPORT
Overview
• All drives leverage 12Gb/s SAS backend connections
– Flash
• eMLC
• TLC
– SAS
• 15K RPM
• 10K RPM
– NL-SAS
• 7.2K RPM

• Flash drives are formatted to 520 bytes/sector


• SAS and NL-SAS drives uses 4K drive block size

13
DRIVE SUPPORT
Unity Hybrid System Drive Matrix

12 Drive DPE 15 Drive DAE 25 Drive DPE /


12Gb Drive Type Supported Capacities (3.5” LFF) (3.5” LFF) 25 Drive DAE
(2.5” SFF)
SSDs for FAST Cache 200GB, 400GB, 800GB* ✔ ✔ ✔
SSD for FAST VP 200GB, 400GB, 800GB, 1.6TB ✔ ✔ ✔
SSDs for “only” All FLASH Pool 400GB, 800GB, 1.6TB, 3.2TB ✔
15K RPM SAS 600GB ✔ ✔ ✔
10K RPM SAS 600GB, 1.2TB, 1.8TB ✔ ✔ ✔
7.2K RPM NL-SAS 2TB, 4TB, 6TB ✔ ✔

* For Unity 600 only with FAST Cache

14
Архитектура

UNISPHERE

Эффективность & DATA


SERVICES

Файловая система

Защита данных

Виртуализация & UNITY VSA


15
UNITY UNISPHERE
• Новый графический интерфейс на основе HTML5
– Wide range of browsers supported

• Uses standard markup language used in web pages


• Supported browsers and versions
– Google Chrome v33 or later
– Internet Explorer v10 or later
– Mozilla Firefox v28 or later
– Apple Safari v6 or later

16
UNISPHERE INITIAL CONFIGURATION
WIZARD
• Guides users in configuring a new storage system
• Seen when logging into Unisphere for the first time
• Configures user and system information
– Unisphere Licenses
– Network settings (i.e. DNS, NTP)
– Provision Storage Pools, FAST Cache, and system interfaces
– Alerts and SMTP settings
– Customer support information

17
UNISPHERE DASHBOARD

18
SYSTEM – SYSTEM VIEW

Commit newly
installed SLICs

19
SYSTEM - PERFORMANCE
• Performance Charts
– System Cache
– System IO
– System Resources
– LUN
– File System
– Fibre Channel Port
– iSCSI Interface
– Ethernet Port
– Disk

• Various metrics chart options can be chosen for each type of


performance chart

20
STORAGE - POOLS
• A single storage pool can source all user resource requirement:
LUNs, File Systems, and VMware VVols
• Modify operations include create, expand, modify, and delete
• User can monitor and configure storage pools
– View current and historical capacity usage
– FAST VP relocation and data distributions across storage pool tiers
– Snapshot storage consumption thresholds and deletion policies

21
22
23
UNISPHERE – SUPPORT
• The Support page provides an ecosystem designed to empower
the end user
– Online Training
• Online training modules, how-to videos, whitepapers
• Downloading the latest product software documentation
• Quick access to EMC online community and support forums
– Contact and Assistance
• Live Chat with EMC Support
• Create a Service Request
• Access to order and replace faulted system components
– Contract and License statuses

24
UNISPHERE – DATA PROTECTION
• Snapshots Schedule
– System Defined Schedules
• Less Protection, Default Protection, More Protection
– Customize schedules based on your SLAs
• Replication
– Manage replication operations such as session failover and failback
– View replication session states and statuses

25
Архитектура

UNISPHERE

Эффективность & DATA


SERVICES

Файловая система

Защита данных

Виртуализация & UNITY VSA


26
FAST CACHE
Architecture & Configuration Options
Protocol End Points • Support for file and block
Maximum
Supported
Replication •System FAST with Flash
Extends cache Drives
VMDK/VHD drives Cache
Unified Svcs

Block
(Thick/Thin
File System
(64-bit)
VVOLs • Unity
Hot data 800 GBs 200GB
automatically &
ends
LUNs) 300in FAST Cache
up 400GB
Unified
Control Unified Pool In an SP failure;
• Unity 1.2 TBs no need
200GBto&
Path
warm
400 up the cache, it’s
400GB
DRAM MAP
mirrored.
Policy Unity 3.2 TBs 200GB &
Engine
Driver 500 400GB
Flash Drives Disk Drives
Unity 6.0 TBs 200GB,
Back End
600 400GB, &
800GB

27
FAST CACHE
• FAST Cache supports online
expansion
– Up to the system maximum
FAST Cache
• FAST Cache supports online 200 GB 200 GB
shrink
200 GB 200 GB
– Ability to remove all but 1 fast
Cache pair

28
FAST CACHE IS VERY SMART
• FAST Cache knows what it was designed for and promotes data
according.
• It will not promote data that already resides on SSDs
• What is not considered for promotion (System Cache is used
instead)

29
FAST VP POLICIES
Policy Ensures Storage Service Levels are Met
Protocol End Points 1. Start High, then Auto-Tier
Maximizes initial performance;
Replication
then optimizes for TCO
VMDK/VHD 2. Auto-Tier
Unified Svcs

Block Optimize TCO and performance


File System VVOLs
(Thick/Thin e.g., databases with varied levels of
(64-bit)
LUNs)
activity among tables, or file
systems with varied levels of
Unified
Unified Pool activity across files
Control
Path 3. Highest Available Tier
Maximize performance
e.g., high-performance OLTP
system
4. Lowest Available Tier
SSD HDD Reduce TCO
e.g., archived or infrequently
Back End
accessed data

30
QUALITY OF SERVICE (QoS)
Priority Controls for Block Storage BLOCK

• Supported on Unity & UnityVSA


IOPS

• System wide Pause/Resume control


– Paused by default BANDWIDTH

• Host IO Limits are based on a user created


policy
– A LUN without a Host IO Limit is not impacted
– Does not limit internal IO (migration, replication, etc.)
– Host IO Limit settings can be changed at any time
• Without Pausing/Resuming Host IO Limits on the system

31
UNIVERSAL API
Managed via Standard REST API

GUI
ONE Architecture CLI
ONE Interface
One Platform

REST
API
INTUITIVE REST API
PROGRAMMER’S GUIDE
WITH MODULAR CODE SNIPPETS

UNIVERSAL INTERFACE
ANY STORAGE | ANY PROTOCOL
ANY STORAGE SUB-SYSTEM

32
ARCHITECTURE

UNISPHERE

EFFICIENCY & DATA SERVICES

FILE SYSTEM

DATA PROTECTION

VIRTUALIZATION & UNITY VSA


33
UNITY FILE SYSTEM
• New 64-bit, 64 TB file system being
introduced in Unity storage systems
• More scalable, flexible, and efficient than
existing 32-bit file systems
• Support for various NAS protocols
– SMB (including SMB 3.02)
– NFS v3 & v4
– FTP/SFTP
– Multiprotocol access to the same file systems

34
UFS64 SCALABILITY

UFS32 UFS64
File system size 16 TB 64 TB (architecture 32 PB)
Files per file system 4 billion > 10’s of billions
File names per directory 500 K ~ 10 million
Subdirectories per directory 64 K ~ 10 million
Maximum file size 16 TB 64 TB (architecture 32 PB)
File system snapshots 96 256 (architecture unlimited)
ACLs per file system 1 million 4 million
Quota trees per file system 2K 8K (architecture unlimited)
Timestamp granularity 1 second 1 nanosecond*

*100 nanosecond granularity exposed to SMB clients


35
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
Private LUN
256MB

RAID Group
256MB
256MB 256MB
256MB 256MB
256MB
256MB
256MB 256MB

256MB
256MB
256MB
256MB
256MB
256MB
UNIFIED STORAGE POOLS

256MB
256MB
256MB
256MB
Storage Pool

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB 256MB
Private LUN

RAID Group

256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
36
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
Private LUN
256MB

RAID Group
256MB
256MB 256MB
256MB 256MB
256MB
256MB
256MB 256MB

256MB
256MB
256MB
256MB
256MB
256MB
UNIFIED STORAGE POOLS

256MB
256MB
256MB
256MB
Storage Pool

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB 256MB
Private LUN

RAID Group

256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
256MB 256MB
37
UNIFIED STORAGE POOLS
NAS NAS User Snap
Server Server File File
Root Config System System
Pool
NAS Server
LUN VVOL VVOL VVOL

File Layer
File File File Snap Snap File File File Snap

NAS Server File System LUN VVol Datastore


Container Container Container Container
Unified Pool

Storage Pool
256MB

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB

256MB
256MB
256MB
256MB
256MB
256MB

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
38
UNITY DATA SERVICES
Unified
– Snapshots and replication
• Unified async replication, ROW
snapshots, and snapshot scheduling
for block and file without savvol
– FAST Cache and FAST VP
• Intelligent data movement with file
system level tiering policies
– Encryption
• Data at Rest controller based
encryption for all block and file data
no impact to performance or data
services

39

Вам также может понравиться