Вы находитесь на странице: 1из 1

DRG.

No : XXXXXXXX SHEET - XXX 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A A

TB1 (230 X 450) RB1 (230 X 450)


8 8 8

800
950
950

C.S OF TIE BEAM C.S OF TIE BEAM

5100

5100

5100
B B
S1 TB1 - (230 x 450) TB1 - (230 x 450)
150mm THK.
AT SUPPORT AT MID SPAN

1000
RB2 (230 X 450)
7 7 7

1125
C C

S2

3750

3750

3750
150mm THK.
C.S OF TIE BEAM C.S OF TIE BEAM
TB2 - (230 x 300) TB2 - (230 x 300)
AT SUPPORT AT MID SPAN
RB2 (230 X 450)
6 6 6
D D
3750

3750

3750
S2
150mm THK.

RB2 (230 X 450)


E
5 5 5 E
EXISTING BUILDING

EXISTING BUILDING

EXISTING BUILDING
C.S OF ROOF BEAM C.S OF ROOF BEAM

RB3 (230 X 450)


TB2 (230 X 300)

RB1 - (230 x 450) RB1 - (230 x 450)


AT SUPPORT AT MID SPAN
3750

3750

3750
S2
150mm THK.

F RB2 (230 X 450) F


4 4 4

S2
3750

3750

3750
150mm THK.

C.S OF ROOF BEAM C.S OF ROOF BEAM


G G
RB2 - (230 x 450) RB2 - (230 x 450)
RB2 (230 X 450)
3 3 3 AT SUPPORT AT MID SPAN
3750

3750

3750
S2
150mm THK.
H H

RB2 (230 X 450)


2 2 2

C.S OF ROOF BEAM C.S OF ROOF BEAM


RB3 - (230 x 450) RB3 - (230 x 450)
AT SUPPORT AT MID SPAN
3750

3750

3750
S2
150mm THK.
I I

TB1 (230 X 450) RB1 (230 X 450)


1 1 1

6150* 6150* 6150*

A B A B A B
LAYOUT OF TIE BEAMS LAYOUT OF ROOF BEAMS LAYOUT OF ROOF SLABS NOTES:-
J J
1. ALL DIMENSIONS ARE IN 'MM' & ALL LEVELS ARE IN 'M'

2. USE CONCRETE MIX : M25

3. LAP LENGTH 50∅

4. CLEAR COVER TO THE REINFORCEMENT FOR

FOOTING : 50MM, COLUMN : 40MM, PLINTH BEAM : 40MM


X
REINFORCEMENT STPS. REINFORCEMENT STPS. ROOF BEAM : 25MM & SLAB : 20MM
K 0.25 L 0.25 L 0.25 L 0.25 L K
5. HIGH YIELD STRENGTH DEFORMED BARS

CONFIRMING IS 1786-1985 TO BE USED


DEPTH

6. Y DENOTES FOR Fe 500 STEEL


0.1 L 0.15 L 0.15 L 0.1 L 7. SBC OF SOIL IS TAKEN AS 20 T/sq.m &
LENGTH LENGTH
2.0M DEPTH BELOW N.G.L

8. ALL STRUCTURAL DRAWINGS ARE TO BE READ


L L
ALONG WITH ARCHITECTURAL DRAWING.
9. FOR LOCATION AND CO-ORDINATE REFER ARCHITECTURAL
SITE LAYOUT.
10. THIS BUILDING IS DESIGNED FOR GROUND FLOOR ONLY.

SLAB REINFORCEMENT DETAILS


DGN. P.S.D TITLE:-
SLAB NO THICK SHORTER DIRECTION ROD LONGER DIRECTION ROD
M DRN. MOHAN M

Y10 AT 100 C/C Y10 AT 100 C/C CHKD. P.S.D LAYOUT & DETAILS OF TIE BEAMS & ROOF BEAMS
S1 125

SIZE : A1
APPD. MOHAN
S2 125 Y10 AT 200 C/C Y10 AT 200 C/C DRG. No :001
DATE 16.05.18 SCALE:- 1:75 SHEET - 1OF1 REV. 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
FILE NAME :- XXXXXXXX

Вам также может понравиться