Академический Документы
Профессиональный Документы
Культура Документы
COARSE TARGETS
TRANSPARENT/MIRROR TARGETS
FINE TARGETS
Highest repeatability in it s class Highest accuracy in its class Fastest in the world
8 ±0.5 mm
LK-H008W 0.005 μm
0.32" ±0.02"
20 ±3 mm
LK-H027 0.02 μm
0.79" ±0.12"
50 ±10 mm
LK-H057 0.025 μm
1.97" ±0.39"
80 ±18 mm 0.1 μm
LK-H087
3.15" ±0.71" 0.000004"
FINE TARGETS
F O CU S ED S P OT T Y P E
8 ±0.5 mm
LK-H008 0.005 μm
0.32" ±0.02"
20 ±3 mm
LK-H022 0.02 μm
0.79" ±0.12"
50 ±10 mm
LK-H052 0.025 μm
1.97" ±0.39"
80 ±18 mm 0.1 μm
LK-H082
3.15" ±0.71" 0.000004"
8 ±0.5 mm
LK-H008 ( W ) 0.005 μm
0.32" ±0.02"
16.1 ±2.8 mm
LK-H027K 0.02 μm
0.63" ±0.11"
46.3 ±5.2 mm
LK-H057K 0.025 μm
1.82" ±0.20"
0.005 µm
The need to improve product quality makes high
performance critical. The LK-G5000 Series provides the
highest repeatability in its class and is highly capable in
any application.
±0.02%
High-linearity enhances the LK-G5000’s capabilities.
By taking advantage of new technology, the series
provides high performance with the high accuracy that
is increasingly required.
392 kHz
The world’s fastest sampling rate not only captures
displacement of moving or rotating targets, but also
increases stability in all manner of applications.
RS-CMOS
R = HIGH-RESOLUTION
S = HIGH-SPEED
MEASUREMENT
PRINCIPLE
HDE Lenses &
Delta Cut Technology
Target
Without DELTA CUT With DELTA CUT
RS-CMOS The focal point RS-CMOS Focal point
is out of place is sharp
3× 4× 8× Conventional model
Dynamic Range Resolution of High-Speed Emission time too short Emission time too long
Laser Emission Time Tracking Capability Too little
laser power
emission time, laser power, and gain. Furthermore, ABLE II Laser power High
ABLE II has a high-speed tracking ability that is eight
times faster than conventional models. Laser power Low
Surfaces that may appear flat, once magnified will often contain minute
projections and depressions. This microscopic surface roughness can often
cause measurement errors with conventional focused spot sensors. By using
a sensor head with a wide beam spot, the effect of the uneven surface is
averaged and stable measurements of even coarse targets are possible.
Conventional LK-H087
2× the
averaging
Semiconductor Semiconductor result
laser laser
2×
Cylindrical lens
S P OT D I A M E T E R
LK-H008W LK-H027 LK-H057 LK-H087 LK-H157
20 × 550 μm 25 × 1400 μm 50 × 2000 μm 70 × 2500 μm 120 × 4200 μm
0.000787" × 0.021654" 0.000984" × 0.055118" 0.001969" × 0.078740" 0.002756" × 0.098425" 0.004724" × 0.165354"
2× wider than
conventional
model
Due to the advanced cylindrical lensing used in the LK-G5000 Series, the wide
axis of the beam spot is kept very consistent throughout the measurement
Measurement of metal surfaces range. This allows the averaging area to stay consistent even if the target is
moved closer to or further from the sensor head.
Conventional
A P P L I C AT I O N
Measurement of electrode thickness Measurement of the disc-rotor vibration Position control of an air knife
Measured value
4 4
0.16" 0.16"
RS-CMOS 3 3
0.12" 0.12"
2 2
Linear collimator lens 0.08" 0.08"
1 1
0.04" 0.04"
0 0
-5 -4 -3 -2 -1 0 1 2 3 4 5 -5 -4 -3 -2 -1 0 1 2 3 4 5
-0.20" -0.16" -0.12" -0.08" -0.04" 0.04" 0.08" 0.12" 0.16" 0.20" -0.20" -0.16" -0.12" -0.08" -0.04" 0.04" 0.08" 0.12" 0.16" 0.20"
Position Position
S P OT D I A M E T E R
LK-H008 LK-H022 LK-H052 LK-H082 LK-H152
ø25μm
ø0.000984" ø20 μm ø25 μm ø50 μm ø70 μm ø120 μm
ø0.000787" ø0.000984" ø0.001969" ø0.002756" ø0.004724"
Unit: mm inch
0.2
0.0079" —LK-H022 — Conventional product
Measurement of the IC pin height
0.1
0.0039"
Measured value
A P P L I C AT I O N
Active layer measurement of solar modules Zoom lens assembly accuracy Measurement of connector height
The LK-G5000 Series incudes a group of heads specifically designed for use
on highly reflective targets such as glass or other mirror surfaces. These heads
are available with wide or focused beam spots and are ideally suited for high
accuracy measurements on such surfaces.
Conventional LK-H052K
0.10 0.10
0.00 0.00
-0.02 -0.02
-0.05 -0.05
-0.10 -0.10
0 Stroke distance [mm inch ] 5 0.20" 0 Stroke distance [mm inch ] 5 0.20"
RS-CMOS
—Sample1 —Sample2 —Sample3 —Sample4 —Sample5
S P OT D I A M E T E R ( W I D E T Y P E )
HDE Lens
LK-H008W LK-H027K LK-H057K LK-H087+LK-F3 LK-H157+LK-F2
20 × 550 μm 25 × 1400 μm 50 × 2000 μm 70 × 2500 μm 120 × 4200μm
0.000787" × 0.021654" 0.000984" × 0.055118" 0.001969" × 0.078740" 0.002756" × 0.098425" 0.004724" × 0.165354"
S P OT D I A M E T E R ( S P OT T Y P E )
Wide/spot
Both types LK-H008 LK-H022K LK-H052K LK-H082+LK-F3 LK-H152+LK-F2
available
ø20 μm ø25 μm ø50 μm ø70 μm ø120μm
ø0.000787" ø0.000984" ø0.001969" ø0.002756" ø0.004724"
50
48 Measurement of the touch panel surface height and air gap
44
42
40
38
36
The optical system in these specialized heads has been 34
32 —OUT1 Air gap
optimized to obtain the maximum resolution possible 30
10
Surface height [µm]
A P P L I C AT I O N
Step measurement between the HDD reader Measurements of glass board thickness,
Z-axis positioning of a patterned wafer arm and the media warpage and parallelism
Remote Control
The controller can be placed
up to 10 m 32.81' away from the
3 S EL E C TA B L E
operation/display units.
ST YLES
Direct Control
The compact controller
with a built-in display
can be operated directly
via easy to use push
buttons incorporated
directly into the unit.
Up to 12 heads connection
* The EtherNet/IPTM interface cannot be used when
LK- G5000 Series 9
a CC-Link unit or a DeviceNetTM unit is installed.
Pursuit of usability and new functions
Instantly calculates values based on measurements obtained by more than one head, enabling the user to easily set complicated
calculations inside the controller that were conventionally done with PLCs or PCs.
Measured value1=B-A Measured value2=B-C Measured value1=MA X(A ,B,C...) Measured value1=MA X(A ,B,C...)−MIN(A ,B,C...)...
Measured value3=A-C… Measured value2=MIN(A ,B,C...)
A B
A D
D E F
Measured value1=B - (A+C)/2… Measured value1=X+(A+D) Measured value2=Y+(B+E) Measured value1=Ave(A ,B,C,D,...)
Measured value3=Z+(C+F)...
Measurement of Speed (m/s), Acceleration (m/s2) Data filter functions made easy
The LK-G5000 Series is equipped with a function to directly 4 types of easy to use data processing filters are incorporated
measure the speed (m/s) and acceleration (m/s2) of targets. directly in the controller. The filters are user selectable for ease
Just select the type of measurement: “displacement”, “speed”, of use.
or “acceleration”. Since the differential processing circuit is
inside the controller, it is possible to directly output or evaluate
measurements that were previously calculated externally. The
Median filter
LK-G5000 Series is suitable for lightweight, easily deformed,
Removes any intermittent noise in the values.
and high-temperature targets which are difficult to measure with
Unfiltered wave pattern Wave pattern when using the median filter
contact accelerometers.
P ER I P H ER A L E Q U I PM EN T
USB / Ethernet
PC
PLC, etc.
Analog
High-flex cables are standard on Because individual head adjustment data is stored within the
the LK-G5000 Series. These cables head itself, all LK-G5000 Series heads are cross-compatible. This
allow the sensors to be safely makes it possible to use any LK-G5000 Series sensor head with
attached to robots etc. any LK-G5000 Series controller.
Drop-down menu Easy to follow illustrations Received-light from the front surface Received-light from the The LK-G5000 can store 1.2 million data points internally. In
back surface addition these can be exported and easily analyzed without
The easy to use menus make configuring the system simple. Mounting errors and stray laser reflections are easy to identify lengthy data processing.
and correct using a simple waveform graph.
17 mm 0.67"
20 mm 0.79" 20 mm ±3 mm 25 µm × 1400 µm
LK-H027 LK-H025 23 mm 0.91" 0.02 µm
0.79" ±0.12" 0.000984" × 0.055118"
Measurement range
40 mm 1.57"
50 mm 1.97"
50 mm ±10 mm 50 µm × 2000 µm
LK-H057 LK-H055 60 mm 2.36" 0.025 µm
1.97" ±0.39" 0.001969" × 0.078740"
Measurement range
62 mm 2.44"
80 mm 3.15" 80 mm ±18 mm 0.1 µm 70 µm × 2500 µm
LK-H087 LK-H085 98 mm 3.86"
3.15" ±0.71" 0.000004" 0.002756" × 0.098425"
Measurement range
110 mm 4.33"
150 mm 5.91" 150 mm ±40 mm 0.25 µm 120 µm × 4200 µm
LK-H157 LK-H155 190 mm 7.48"
5.91" ±1.57" 0.000010" 0.004724" × 0.165354"
Measurement range
17 mm 0.67"
20 mm 0.79" 20 mm ±3 mm ø25 µm
LK-H022 LK-H020 23 mm 0.91" 0.02 µm
0.79" ±0.12" ø0.000984"
Measurement range
40 mm 1.57"
50 mm 1.97" 50 mm ±10 mm ø50 µm
LK-H052 LK-H050 60 mm 2.36" 0.025 µm
1.97" ±0.39" ø0.001969"
Measurement range
62 mm 2.44"
80 mm 3.15"
80 mm ±18 mm 0.1 µm ø70 µm
LK-H082 LK-H080 98 mm 3.86"
3.15" ±0.71" 0.000004" ø0.002756"
Measurement range
110 mm 4.33"
150 mm 5.91" 150 mm ±40 mm 0.25 µm ø120 µm
LK-H152 LK-H150 190 mm 7.48"
5.91" ±1.57" 0.000010" ø0.004724"
Measurement range
20 µm × 550 µm
Wide LK-H008W —
8 mm 0.31" 0.000787" × 0.021654"
8 mm ±0.5 mm
0.005 µm
0.32" ±0.02" ø20 µm
Spot LK-H008 — Measurement range
ø0.000787"
Wavelength 655 nm 650 nm 650 nm 650 nm 650 nm 655 nm 650 nm 655 nm 650 nm
Laser IEC 60825-1 Class 1 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2
class FDA(CDRH)21CFR Part 1040.10 Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II
Output 0.3mW 4.8mW 0.95mW 4.8mW 0.95mW 4.8mW 0.95mW 4.8mW 0.95mW
20 μm × 550 μm 25 μm × 1400 μm 50 μm × 2000 μm 70 μm × 2500 μm 120 μm × 4200 μm
Spot diameter (at reference distance)
0.000787" × 0.021654" 0.000984" × 0.055118" 0.001969" × 0.078740" 0.002756" × 0.098425" 0.004724" × 0.165354"
±0.05% of F.S. ±0.02%of F.S. ±0.02% of F.S. ±0.02% of F.S. ±0.02% of F.S.
Linearity* 2
(F.S.=1 mm 0.04") (F.S.= 6 mm 0.24") (F.S.= 20 mm 0.79") (F.S.= 36 mm 1.42") (F.S.= 80 mm 3.15")
Repeatability* 3 0.005 μm (0.001 μm) 0.02 μm (0.01 μm) 0.025 μm 0.1 μm 0.000004" 0.25 μm 0.000010"
Sampling cycle 2.55/5/10/20/50/100/200/500/1000 μs (9 steps selectable)
0.02% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C
Temperature fluctuation
(F.S.=1 mm 0.04") (F.S.= 6 mm 0.24") (F.S.= 20 mm 0.79") (F.S.= 36 mm 1.42") (F.S.= 80 mm 3.15")
Enclosure rating IP67
Environment resistance
Incandescent lamp
Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max. or fluorescent lamp
: 5000 lux max.
Ambient temperature 0 to +50°C 32 to 122°F *4 0 to +50°C 32 to 122°F 0 to +50°C 32 to 122°F *4
Relative humidity 35 to 85%RH (No condensation)
Vibration resistance 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively
Material Aluminum die-cast
Weight Approx. 240 g Approx. 230 g Approx. 260 g Approx. 280 g Approx. 300 g
*1 Measurement range when the sampling cycle is 20 μs or more. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384.
The value in parentheses is a typical example of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs. *4 When the ambient temperature rises to 40°C 104°F or more, mount this on a metal plate before use.
Wavelength 655 nm 650 nm 650 nm 650 nm 650 nm 655 nm 650 nm 655 nm 650 nm
Laser IEC 60825-1 Class 1 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2 Class 3R Class 2
class FDA(CDRH)21CFR Part 1040.10 Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II Class IIIa Class II
Output 0.3mW 4.8mW 0.95mW 4.8mW 0.95mW 4.8mW 0.95mW 4.8mW 0.95mW
Spot diameter (at reference distance) ø20 μm ø0.000787" ø25 μm ø0.000984" ø50 μm ø0.001969" ø70 μm ø0.002756" ø120 μm ø0.004724"
±0.05% of F.S. ±0.02% of F.S. ±0.02% of F.S. ±0.02% of F.S. ±0.02% of F.S.
Linearity* 2
(F.S.=1 mm 0.04") (F.S.= 6 mm 0.24") (F.S.= 20 mm 0.79") (F.S.= 36 mm 1.42") (F.S.= 80 mm 3.15")
Repeatability* 3 0.005 μm (0.001 μm) 0.02 μm (0.01 μm) 0.025 μm 0.1 μm 0.000004" 0.25 μm 0.000010"
Sampling cycle 2.55/5/10/20/50/100/200/500/1000 μs (9 steps selectable)
0.02% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C 0.01% of F.S./°C
Temperature fluctuation
(F.S.=1 mm 0.04") (F.S.= 6 mm 0.24") (F.S.= 20 mm 0.79") (F.S.= 36 mm 1.42") (F.S.= 80 mm 3.15")
Enclosure rating IP67
Environment resistance
Incandescent lamp
Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max. or fluorescent lamp
: 5000 lux max.
Ambient temperature 0 to +50°C 32 to 122°F *4 0 to +50°C 32 to 122°F 0 to +50°C 32 to 122°F *4
Relative humidity 35 to 85%RH (No condensation)
Vibration resistance 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively
Material Aluminum die-cast
Weight Approx. 240 g Approx. 230 g Approx. 260 g Approx. 280 g Approx. 300 g
*1 Measurement range when the sampling cycle is 20 μs or more. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008) is measured at the reference distance with the number of averaging measurements set to 16384.
The value in parentheses is a typical example of a measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 µs. *4 When the ambient temperature rises to 40°C 104°F or more, mount this on a metal plate before use.
Incandescent lamp or
Ambient light Incandescent lamp or fluorescent lamp: 10000 lux max. fluorescent lamp
: 5000 lux max.
Ambient temperature 0 to +50°C 32 to 122°F *5 0 to +50°C 32 to 122°F 0 to +50°C 32 to 122°F *5
Relative humidity 35 to 85% RH (No condensation)
Vibration resistance 10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively
Material Aluminum die-cast
Weight Approx. 240 g Approx. 230 g Approx. 260 g Approx. 280 g Approx. 300 g
*1 Measurement range when the sampling cycle is 20 μs or more. *2 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured in the normal measurement mode.
*3 This value is obtained when the KEYENCE standard target (White diffuse workpiece or workpiece with a metal mirror surface only for the LK-H008/LK-H008W) is measured at the reference distance with the number of averaging measurements set to 16384. The value in parentheses is a typical example of a
measurement with the number of averaging measurements set to 65536 and the sampling cycle to 200 μs.
*4 Use one of the following dark filters when measuring a transparent or mirror surface object: LK-H082/LK-H087: LK-F3, LK-H152/LK-H157: LK-F2 *5 When the ambient temperature rises to 40°C 104°F or more, mount this on a metal plate before use.
*6 Value measured at an event of diffuse reflection installation. Please contact us for the case of specular reflection installation.
* Use under an environment that exceeds the recommended environment of the your OS.
*1 Home, Pro, and Enterprise editions are supported.
*2 Home Premium, Professional, and Ultimate editions are supported.
*3 Ultimate, Business, Home Premium, and Home Basic editions are supported.
*4 Professional and Home editions are supported.
*5 Connection through a USB hub is not included in the guarantee.
*6 Connection to LAN and connection via a router is not included in the guarantee.
Built-in type Separate display type Additional head unit CC-Link unit DeviceNetTM unit Touch panel display Compact display
LK-G5001(P)V LK-G5001(P) LK-H A100 LK-CC100 LK-DN100 LK-HD1001 LK-HD500
S P E C I FI C AT I O N S
Sensor head-to-controller cable Extension cable between the head and cable
Model CB-A07 CB-A2 CB-A5 CB-A10 CB-A20 CB-A30 Model CB-A5E CB-A10E
Cable Cable
0.7 m 2.30' 2 m 6.56' 5 m 16.40' 10 m 32.81' 20 m 65.62' 30 m 98.43' 5 m 16.40' 10 m 32.81'
length length
Weight Approx. 100 g Approx. 200 g Approx. 400 g Approx. 750 g Approx. 1400 g Approx. 2000 g Weight Approx. 400 g Approx. 750 g
D I M EN S I O N S
75 + 0.6 +0.02"
0 2.95" 0
5.05"
178 128.2 167 91 80 74.5
7.01" (Effective 6.57" 3.58"3.15" 2.93"
display area) 100 min.
3.94" 45 + 0.6
0
1.77" +0.02"
51 0.33" 8.5 0
25
2.01" 0.98"
WARNING
The LK-G Series conforms to the following FDA and IEC standards:
LK-H008/ LK-H022/H022K/H027/H027K/H052/H052K/ LK-H020/H025/H050/H055/
Model
LK-H008W H057/H057K/H082/H087/H152/H157 LK-H080/H085/H150/H155
FDA (CDRH)
Laser Class II Laser Class II Laser Class IIIa
21CFR Part 1040.10
IEC60825-1 Laser Class 1 Laser Class 2 Laser Class 3R
FDA
CAUTION AVOID EXPOSURE
CAUTION AVOID EXPOSURE
LASER RADIATION- LASER RADIATION- LASER RADIATION-
AVOID EXPOSURE DO NOT STARE INTO BEAM LASER RADIATION DO NOT STARE INTO BEAM AVOID DIRECT EYE EXPOSURE LASER RADIATION
SEMICONDUCTOR LASER IS EMITTED FROM SEMICONDUCTOR LASER SEMICONDUCTOR LASER IS EMITTED FROM
LASER RADIATION WAVELENGTH 655nm THIS APERTURE. WAVELENGTH 650nm WAVELENGTH 650nm THIS APERTURE.
IS EMITTED FROM
MAXIMUM OUTPUT 0.3mW MAXIMUM OUTPUT 0.95mW MAXIMUM OUTPUT 4.8mW
THIS APERTURE.
CLASS LASER PRODUCT CLASS LASER PRODUCT CLASS a LASER PRODUCT
Unit: mm inch
Controller
LK-G5001(P)V LK-G5001(P)
65 128 (65) 65 (65) 105.5
2.56" 5.04" (2.56") 2.56" (2.56") 4.15"
62.1
2.44"
0.24"6 0.24"6
47 47
1.85" 1.85"
9 0.35" 9 0.35"
34.5 79.5 4 × M4 Depth: 6 0.24" 14 79.5 4 × M4 Depth: 6
1.36" 3.13" 0.55" 3.13" 0.24"
124 124
4.88" 4.88" 35.9 1.41"
62.1 2.44"
0.24" 6 0.24" 6
M4 Depth: 6 0.24"
13.5 0.53"
124 124
4.88" 4.88" 35.9 1.41"
62.1 2.44"
0.24" 6 0.24" 6
M4 Depth: 6 0.24"
(3.2) (0.13")
0.53" 13.5
13.5 0.53"
(0.13") (3.2)
M4 Depth: 6 0.24" 14
114 4.49" 0.55"
124 124
4.88" 4.88" 35.9 1.41"
62.1 2.44"
0.24" 6 0.24" 6
M4 Depth: 6 0.24"
(3.2) (0.13")
0.53" 13.5
13.5 0.53"
(0.13") (3.2)
M4 Depth: 6 0.24" 14
114 4.49" 0.55"
Unit: mm inch
Head ø14
ø0.55"
LK-H008 / LK-H008W
55
2.17"
500
31.2 1.23" 19.69"
22.8 0.90" ø7 ø0.28"
12.7 13.5 0.53"
13.5 max. 0.5" LASER ON/STABILITY LED
0.53"
0.5 0.02"
73.5 57.5
2.89" 2.26" 2 × ø4.4 ø0.17"
Mounting hole
0.46"11.8 90°
8
0.32" 12.3 0.48"
66
2.60" 27.5
1.08"
ø14
ø0.55"
LK-H020/LK-H022/
LK-H025/LK-H027 LK-H022K/LK-H027K
55
2.17"
500
19.69" 75.9 2.99"
11 ø7 4.6 66.6 2.62"
LASER ON/STABILITY LED 0.43" 0.18"
15 13.4 ø0.28"
0.59" 0.53"
13 max.
0.51"
0.5
0.02" 89 max.
77.7
3.50"
3.06"
62 53.4 55.4
2.44" 2.1" 2.18"
22.8
0.90"
40° 40°
2 × ø4.4 ø0.17" 16.1 0.63"
20 4.4
0.79" 0.17" Mounting hole
ø14
ø0.55"
55
2.17"
LK-H050/LK-H052/ LK-H052K/LK-H057K
LK-H055/LK-H057 500
19.69" 74.8 2.94"
ø7 ø0.28" 37.6 1.48"
LASER ON/STABILITY LED 10.1 max. 13.4
22.1
0.40" 0.53"
ø0.17" 0.87"
7.7 max. 24 2 × ø4.4
0.30" 0.94" Mounting hole
0.5
0.02"
89.9 max.
68.5 59.9 3.54"
68
2.70" 2.36" 2.68"
0.40"
10.1
4.4 30°
30°
50 0.17" 46.3
1.97" 1.82"
9.2 12.2
0.36" 0.48"
ø14
ø0.55" Unit: mm inch
LK-H080 / LK-H082/ 55
LK-H085 / LK-H087 2.17"
500
19.69"
80.3
ø7 ø0.28" 3.16"
LASER ON/STABILITY LED 10.1 max. 35.4
ø0.17" 13.5 1.39"
7.7 max. 2 × ø4.4 0.40" 0.53"
24 22.7
0.30" Mounting hole 0.89"
0.94"
0.5
0.02"
90.5 max.
70 3.56"
61.4
2.76" 2.42" 69
2.72"
9
0.35"
4.4
0.17"
24° 24°
80
3.15" 76.7
3.02"
9.2 12.3
0.36" 0.48"
55
LK-H150 / LK-H152/ 2.17"
LK-H155 / LK-H157
500
19.69" 86.6
LASER ON/STABILITY LED 0.16" 3.41"
3.24" 4 ø7 ø0.28" 20.6
82.2 0.81"
20.2 ø0.17" 33.3 10.1
0.02" 0.8" 2 × ø4.4 1.31" 0.40"
0.6 Mounting hole
76.2 68 84.3
3" 2.68" 67.3 3.32"
2.65"
6.8
0.27"
4.2
0.17"
8.2 18
0.32" 0.71"
150 17°
5.91" 147.5
17° 5.81"
1.02" 26
0.45" 11.5
WIDE-RANGE MEASUREMENT
UP to 1000 mm 39.37"
HIGH-ACCURACY WIDE PRODUCT LINEUP REPEATABILITY
Type Spot type Model Reference distance & Measurement range Repeatability Beam spot dimensions
Detecting displacement of a water Measuring the thickness/width of a steel plate Thickness measurement/loop control of a rubber sheet
www.keyence.com
E-mail: keyence@keyence.com
E-mail: keyencecanada@keyence.com
E-mail: keyencemexico@keyence.com
Copyright (c) 2018 KEYENCE CORPORATION. All rights reserved. LKG5-KA-C3-US 1048-1 611H36