Application Manual for NEMA Motors

Section 5

Electrical Information Page

Part 1 Frame Assignment

Part 2 Speed Torque Curves


GP10 1
GP10A 32
GP100 63
GP100A 88
RGZEESD 113
RGZEESDX 178
RGZESD 241
RGZP (SD) 329
RGZZESD 385
SD10 465
SD100 IEEE-841 496
SD100 521

Part 3 Insulation System

Part 4 External Load WK2 Capabilities

Part 5 Connection Diagrams


Single Speed
Two Speed

Part 6 Temperature Rise

Part 7 Reduction Factors


SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%
CURRENT

900%
400%

800%
350%

700%
300% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

CURRENT

300%
500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

300% 500%

CURRENT
450%

250%
400%

350%
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE

150% 250%

200%

100%
150%

100%
50%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% TORQUE 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

900%
400% CURRENT

TORQUE 800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 700%

400% CURRENT
600%

350%

500%

300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
250%
TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

450% 600%

CURRENT
400%

500%

350%

300% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250%

300%

200%

150% 200%

100%

100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

CURRENT

900%
400%

800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
TORQUE
250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 900%

CURRENT
450%
800%
TORQUE

400%
700%

350%
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

500%

250%

400%

200%

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURVE VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 600%

CURRENT

350%
500%

300%

400%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 300%

150%
200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 1000%

CURRENT
900%
350%

800%

300%

700%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

200% TORQUE 500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 900%

CURRENT 800%
350%

700%
300%

600%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

500%
TORQUE
200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300%
CURRENT 500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%
TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT 500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 900 TYPE GP10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT
350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE GP10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%

CURRENT

300% 600%

250% TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
CURRENT
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE GP10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
250% CURRENT

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE GP10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%
CURRENT

900%
400%

800%
350%

700%
300% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

CURRENT

300%
500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

300% 500%

CURRENT
450%

250%
400%

350%
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE

150% 250%

200%

100%
150%

100%
50%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% TORQUE 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

900%
400% CURRENT

TORQUE 800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 700%

400% CURRENT
600%

350%

500%

300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
250%
TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

450% 600%

CURRENT
400%

500%

350%

300% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250%

300%

200%

150% 200%

100%

100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

CURRENT

900%
400%

800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
TORQUE
250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 900%

CURRENT
450%
800%
TORQUE

400%
700%

350%
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

500%

250%

400%

200%

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURVE VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 600%

CURRENT

350%
500%

300%

400%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 300%

150%
200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 1000%

CURRENT
900%
350%

800%

300%

700%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

200% TORQUE 500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 900%

CURRENT 800%
350%

700%
300%

600%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

500%
TORQUE
200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300%
CURRENT 500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%
TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT 500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 900 TYPE GP10A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT
350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE GP10A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%

CURRENT

300% 600%

250% TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
CURRENT
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE GP10A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
250% CURRENT

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE GP10A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%
CURRENT

500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

300%

600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1200%
CURRENT

450%

1000%
400%

350%
800%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 600%
TORQUE

200%

400%
150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT 700%

350%
600%

300%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

400%

200% TORQUE

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%

CURRENT
500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE
600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%
CURRENT

450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%
CURRENT

400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450% CURRENT
700%

400%

600%

350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

TORQUE
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
TORQUE 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE GP100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% TORQUE 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%
TORQUE
200%

% FULL L0AD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE GP100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE GP100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%
CURRENT

500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

300%

600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1200%
CURRENT

450%

1000%
400%

350%
800%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 600%
TORQUE

200%

400%
150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT 700%

350%
600%

300%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

400%

200% TORQUE

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%

CURRENT
500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE
600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%
CURRENT

450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%
CURRENT

400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450% CURRENT
700%

400%

600%

350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

TORQUE
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
TORQUE 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE GP100A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% TORQUE 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%
TORQUE
200%

% FULL L0AD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE GP100A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE GP100A

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT
700%

350%
600%

300%
500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

250%

400%

200%

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300%
CURRENT 500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200%

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

400% 800%
CURRENT

350% 700%

TORQUE
300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%
CURRENT

450%
700%

400%

600%
TORQUE
350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

CURRENT 900%
400%

800%
350%

700%
300%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450%
CURRENT
700%

400%

600%
TORQUE
350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 900%

CURRENT

800%
350%

700%
300%

TORQUE
600%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%

700%
TORQUE
250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

800%
CURRENT
300%

700%

250% TORQUE
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT

800%
300%

700%
TORQUE
250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
TORQUE
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

TORQUE
600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE VS. SPEED

300%

250% TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE 600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE VS. SPEED

350%

300%
TORQUE

250%
% FULL LOAD TORQUE

200%

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE VS. SPEED

300%

250% TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%
TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 284TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 25 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 230/460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 230/460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 286TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 324TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
1 26 51 76 101
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 326TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE VS. SPEED

250%

200%
TORQUE
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 364TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE VS. SPEED

300%

250%

TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
1 26 51 76 101
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 365TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE VS. SPEED

300%

250%

TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 75 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 100 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 100 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT 600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 125 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 445TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 150 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE VS. SPEED

250%

200%

TORQUE
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 447TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%
CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 200 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA A

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

400%

100% TORQUE
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME 449TS NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT
600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1200 TYPE RGZEESD

HZ 60 PHASE 3 FRAME S449 NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE 400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%
% FULL LOAD TORQUE

150%

400%

100%
TORQUE 300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100% TORQUE

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 400 VOLTS 460 RPM 3600 TYPE RGZEESD

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

TORQUE

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 400 VOLTS 460 RPM 1800 TYPE RGZEESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
TORQUE
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT
700%

350%
600%

300%
500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

250%

400%

200%

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300%
CURRENT 500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200%

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

400% 800%
CURRENT

350% 700%

TORQUE
300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%
CURRENT

450%
700%

400%

600%
TORQUE
350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

CURRENT 900%
400%

800%
350%

700%
300%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450%
CURRENT
700%

400%

600%
TORQUE
350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 900%

CURRENT

800%
350%

700%
300%

TORQUE
600%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%

700%
TORQUE
250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

800%
CURRENT
300%

700%

250% TORQUE
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT

800%
300%

700%
TORQUE
250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
TORQUE
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

TORQUE
600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE VS. SPEED

300%

250% TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE 600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE VS. SPEED

350%

300%
TORQUE

250%
% FULL LOAD TORQUE

200%

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE VS. SPEED

300%

250% TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%
TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 20 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 284TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 25 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 286TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 324TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
1 26 51 76 101
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 326TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE VS. SPEED

250%

200%
TORQUE
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC. Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
1 26 51 76 101
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 364TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE VS. SPEED

300%

250%

TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 365TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE VS. SPEED

300%

250%

TORQUE

200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 75 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 100 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 100 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT 600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 125 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 445TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 150 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE VS. SPEED

250%

200%

TORQUE
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 447TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%
CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 200 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 449TS NEMA A

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME 449TS NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME S449 NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT
600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1200 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME S449 NEMA A

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE 400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%
% FULL LOAD TORQUE

150%

400%

100%
TORQUE 300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 1800 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100% TORQUE

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 400 VOLTS 460 RPM 3600 TYPE RGZEESDX

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

TORQUE

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300% CURRENT
500%
TORQUE

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

300% 450%
CURRENT

400%

250%

TORQUE 350%

200% 300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

150%

200%

100% 150%

100%

50%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%
TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT

800%
300%
TORQUE

700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%
TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

250% CURRENT 500%

TORQUE

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 1000%
CURRENT

900%
300%
TORQUE
800%

250%
700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
200%

500%

150%
400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%

CURRENT
300% 600%

250% 500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

700%

250%
TORQUE
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% TORQUE 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE
600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
TORQUE
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% 400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%
TORQUE

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

TORQUE
600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 10 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%
TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 600%
CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE & CURRENT VS. SPEED

250% 500%
CURRENT

450%

TORQUE
200% 400%

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 284TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 500%
CURRENT

450%

200% 400%
TORQUE

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 286TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE & CURRENT VS. SPEED

250% 500%
CURRENT

450%

TORQUE
200% 400%

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 324TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 40 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 500%

CURRENT

450%

200% 400%
TORQUE

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 326TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 50 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 404T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

TORQUE 500%
200%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 364TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 404T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 60 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%
CURRENT

600%
TORQUE
200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 365TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 445TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 447TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%
CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 200 VOLTS 460 RPM 900 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

400%

100% TORQUE
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT
600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE 400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE VS. SPEED

300%

250%

200%
% FULL LOAD TORQUE

TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%
% FULL LOAD TORQUE

150%

400%

100%
TORQUE 300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100% TORQUE

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

CUSTOMER: ______________________ PO#: ______________________ ORDER#: ______________________

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 350 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100% TORQUE

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 400 VOLTS 460 RPM 3600 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449SS NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

TORQUE

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 400 VOLTS 460 RPM 1800 TYPE RGZESD

HZ 60 PHASE 3 FRAME S449 NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
TORQUE
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300% CURRENT
500%
TORQUE

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%
TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT

800%
300%
TORQUE

700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 1000%
CURRENT

900%
300%
TORQUE
800%

250%
700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
200%

500%

150%
400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 1000%
CURRENT

900%
300%

800%
TORQUE

250%
700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
200%

500%

150%
400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%
TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%
CURRENT

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%
TORQUE

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

TORQUE
600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 1800 TYPE RGZPSD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%
TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 600%
CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 284TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 286TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 324TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 40 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 326TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 364TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 404T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT
600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 365TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

700% 250%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 125 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 3600 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 445TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 3600 TYPE RGZPSD

HZ 60 PHASE 3 FRAME 447TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1800 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1200 TYPE RGZP(SD)

HZ 60 PHASE 3 FRAME 449T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300% CURRENT
500%
TORQUE

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

300% 450%
CURRENT

400%

250%

TORQUE 350%

200% 300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

150%

200%

100% 150%

100%

50%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%
TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT

800%
300%
TORQUE

700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%
TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

250% CURRENT 500%

TORQUE

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 1000%
CURRENT

900%
300%
TORQUE
800%

250%
700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
200%

500%

150%
400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300% TORQUE

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%

CURRENT
300% 600%

250% 500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

700%

250%
TORQUE
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

TORQUE
700%

250%

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%

CURRENT
800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% TORQUE 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 900%
CURRENT

800%
300%

700%

250% TORQUE

600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT
700%
300%

TORQUE
600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
TORQUE
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

200% 400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%
TORQUE

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

TORQUE
600%

200%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 10 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 800%
CURRENT

700%
250%

600%

200% TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 400%

300%
100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

500%
TORQUE
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 15 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%
TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 20 VOLTS 230/460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 600%
CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 230/460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE & CURRENT VS. SPEED

250% 500%
CURRENT

450%

TORQUE
200% 400%

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 284TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 284T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

400%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 25 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 500%
CURRENT

450%

200% 400%
TORQUE

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 286TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 30 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 286T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 30 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE & CURRENT VS. SPEED

250% 500%
CURRENT

450%

TORQUE
200% 400%

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 324TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 324T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 40 VOLTS 460 RPM 1200 TYPE RGZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 40 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 500%

CURRENT

450%

200% 400%
TORQUE

350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

250%

100% 200%

150%

50% 100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 326TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

TORQUE
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 326T NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 50 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 50 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 404T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%
CURRENT

TORQUE 500%
200%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 364TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%
CURRENT

600%
250%

500%

200% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 364T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 60 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 404T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 60 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%
CURRENT

600%
TORQUE
200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 365TS NEMA B

TORQUE AND CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 365T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 75 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 405TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 405T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 100 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 444TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 444T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%
TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 125 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 445TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 445T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


TORQUE
% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 150 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 447TS NEMA B

TORQUE AND CURRENT VS. SPEED

250% 800%
CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 447T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%
CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% TORQUE
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors
HP 200 VOLTS 460 RPM 900 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449T NEMA B

TORQUE AND CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
TORQUE

400%

100%
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE VS. SPEED

250%

TORQUE
200%
% FULL LOAD TORQUE

150%

100%

50%

0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 250 VOLTS 460 RPM 1200 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 3600 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 800%

CURRENT

700%

200%

600%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

400%

100% TORQUE
300%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
MOTORS & DRIVES DIVISION
Application Manual for NEMA Motors

HP 300 VOLTS 460 RPM 1800 TYPE RGZZESD

HZ 60 PHASE 3 FRAME 449TS NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT
600%

200%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%
TORQUE

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% TORQUE 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

900%
400% CURRENT

TORQUE 800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 700%

400% CURRENT
600%

350%

500%

300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
250%
TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

450% 600%

CURRENT
400%

500%

350%

300% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250%

300%

200%

150% 200%

100%

100%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%
CURRENT

900%
400%

800%
350%

700%
300% TORQUE

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

CURRENT

300%
500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

300% 500%

CURRENT
450%

250%
400%

350%
200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE

150% 250%

200%

100%
150%

100%
50%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

450% 1000%

CURRENT

900%
400%

800%
350%

700%
300%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%
TORQUE
250%

500%

200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 900%

CURRENT
450%
800%
TORQUE

400%
700%

350%
600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

500%

250%

400%

200%

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURVE VS. SPEED

450% 900%

400% CURRENT 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250% 500%
TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 600%

CURRENT

350%
500%

300%

400%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 300%

150%
200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 1000%

CURRENT
900%
350%

800%

300%

700%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

600%

200% TORQUE 500%

400%
150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

400% 900%

CURRENT 800%
350%

700%
300%

600%
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

500%
TORQUE
200%

400%

150%
300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 600%

300%
CURRENT 500%

250%

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%
TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%
TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%

CURRENT

700%
300%

600%
250%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT 500%
200%
TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE 400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 900 TYPE SD10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 600%

CURRENT

500%
200%

TORQUE

400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT
350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE SD10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT

600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 700%

CURRENT

300% 600%

250% TORQUE 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
CURRENT
250%

TORQUE

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE SD10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

600%
250% CURRENT

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE SD10

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% 500%

TORQUE
200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1200%
CURRENT

450%

1000%
400%

350%
800%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 600%
TORQUE

200%

400%
150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT 700%

350%
600%

300%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

400%

200% TORQUE

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%
CURRENT

500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

300%

600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%

CURRENT
500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE
600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%
CURRENT

450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%
CURRENT

400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450% CURRENT
700%

400%

600%

350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

TORQUE
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
TORQUE 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE SD100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% TORQUE 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%
TORQUE
200%

% FULL L0AD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE SD100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE SD100

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1200%
CURRENT

450%

1000%
400%

350%
800%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 600%
TORQUE

200%

400%
150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%

CURRENT
450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1.5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 800%

400% CURRENT 700%

350%
600%

300%
500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

250%

400%

200% TORQUE

300%
150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%
TORQUE

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 143T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%
CURRENT

500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

300%

600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 1 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

550% 1200%

CURRENT
500%

1000%
450%

400%

800%
350%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%
TORQUE
600%

250%

200%
400%

150%

100%
200%

50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 145T NEMA B

TORQUE & CURRENT VS. SPEED

500% 1000%
CURRENT

450% 900%

400% 800%

350% 700%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300% 600%

TORQUE

250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 2 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%

CURRENT
400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 182T NEMA B

TORQUE & CURRENT VS. SPEED

450% 900%
CURRENT

400% 800%

350% 700%

300% 600%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
250% 500%

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 3 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

% FULL LOAD CURRENT


250% 500%
% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

500% 800%

450% CURRENT
700%

400%

600%

350%

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

300%

250% 400%

TORQUE

200%
300%

150%

200%

100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 184T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

TORQUE
250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT

350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE

200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

CURRENT
350% 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200% TORQUE 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 213T NEMA B

TORQUE & CURRENT VS. SPEED

400% 700%

CURRENT

350%
600%

300%
500%

TORQUE
250%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

200%

300%

150%

200%
100%

100%
50%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 7.5 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

600%
CURRENT
200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

400% 800%

350% CURRENT 700%

300% 600%

250% 500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

TORQUE
200% 400%

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 215T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
TORQUE 600%
250%

500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 10 VOLTS 460 RPM 1200 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 600%

CURRENT

250% TORQUE 500%

200% 400%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150% 300%

100% 200%

50% 100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

350% 800%
CURRENT

700%
300%

600%
250%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

200%

400%

150%

300%

100%
200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 15 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 254T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT 600%
250%

500%
TORQUE
200%

% FULL L0AD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 3600 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

300% 700%

CURRENT
600%
250%

TORQUE 500%

200%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

400%

150%

300%

100%

200%

50%
100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1
SIEMENS ENERGY & AUTOMATION, INC.Section 5
Part 2
Application Manual for NEMA Motors

HP 20 VOLTS 460 RPM 1800 TYPE SD100 IEEE-841

HZ 60 PHASE 3 FRAME 256T NEMA B

TORQUE & CURRENT VS. SPEED

250% 700%

CURRENT

600%

200%
TORQUE

500%

% FULL LOAD CURRENT


% FULL LOAD TORQUE

150%
400%

300%
100%

200%

50%

100%

0% 0%
0% 25% 50% 75% 100%
% SYNCHRONOUS SPEED

Customer: PO No.: Order No.:

PERFORMANCE BASED ON DESIGN CALCULATIONS. SUBJECT TO CHANGE WITHOUT NOTICE.


REV. 1

Вам также может понравиться