Job Info: Job Info: Job 21: "getting ing" Current Version: Version 8: Comments: get 0005 Created on: 2018-06-30 by: admin Language Show system messages in English Options: Manual Signal Silence Yes Fire Drill Yes Waterflow Retard Operation No Auxiliary Disconnect Alm&Spv No Alarm Transmit Silence No Common Supervisory Relay No Signal Isolator Used No Strobes Type Normal Evacuation Code Continuous Two Stage Operation No Second Stage Alarm Relay Op. N/A Monitor alert No Polled Device Flashes Yes Class A Loop No Agency Selection ULC Standard Positive Alarm Sequence No Timers: Signal Silence Inhibit Disabled Auto Signal Silence Disabled General Alarm N/A Power Fail Delay None Date and Time: Enable Daylight Saving Yes Clock Daily Compensation (sec) 0 Enable Auto After Hours No Day Start Time: N/A Night Start Time: N/A Weekend Start: N/A Weekend End: N/A Holidays Reprogram Holiday Trouble: N/A N/A Holidays Defined xxxx-01-01 xxxx-12-25 - xxxx-12-26
Job21-08: getting ing Page 1 of 7
Job21-08: getting ing sábado, 30 de junio de 2018 Job Details: FX-350/1/3-126 Series / Base I/O / Loop 0 (Hardwired)
Addr Device Type F1 F3 Tag (Line1) Tag (Line2) Delay
Job21-08: getting ing sábado, 30 de junio de 2018 Job Details: FX-350/1/3-126 Series / Base I/O / Loop 1
Addr Device Type F1 F3 Sens Tag (Line1) Tag (Line2) Delay
1 Photo Det Alarm Input 3.20% Sensor de Humo Garita 1CCTV 2 Photo Det Alarm Input 3.20% Sensor de Humo Ofic. Admin 2 Piso 3 Photo Det Alarm Input 3.20% Sensor de Humo Mant 1 Piso 4 Photo Det Alarm Input 3.20% Sensor de Humo Comedor 5 Photo Det Alarm Input 3.20% Sensor de Humo Ofic. Recepcion 6 Photo Det Alarm Input 3.20% Sensor de Humo Gerencia 7 Photo Det Alarm Input 3.20% Sensor de Humo Sala de Reuniones 8 Photo Det Alarm Input 3.20% Sensor de Humo Subestacion 9 Photo Det Alarm Input 3.20% Sensor de Humo Garita 2 10 Photo Det Alarm Input 3.20% Sensor de Humo Almacen 2 11 Photo Det Alarm Input 3.20% Sensor de Humo Electrobomba 101 Contact Mini Module Alarm Input Estacion Manual Tango 1 102 Contact Mini Module Alarm Input Estacion Manual Comedor 103 Contact Mini Module Alarm Input Estacion Manual Tango 2 104 Contact Mini Module Alarm Input Estacion Manual Pati 2 Nave 2 105 Contact Mini Module Alarm Input Estacion Manual Pati 4 Nave 5 6 106 Contact Mini Module Alarm Input Estacion Manual Pati 3 Nave 6 107 Contact Mini Module Alarm Input Estacion Manual Pati 3 Nave 5 108 Contact Mini Module Alarm Input Estacion Manual Pati 1 Nave 2
Job21-08: getting ing Page 3 of 7
Job21-08: getting ing sábado, 30 de junio de 2018 Job Details: FX-350/1/3-126 Series / Main Display
Section Name Value
System Messages System Normal Sistema sin Problema Pass Codes Level 1 1111 Level 2 2222 Level 3 3333 Access Levels Reports 0 Aux Bypass 0 Dev Bypass 1 Group Bypass 1 Loop Bypass 1 Walk Test 1 Set After Hours 0 Set Time/Date 1 Daylight Saving and Clock 1 Clear Event Logs 2 Clear Verif Cntrs 2 Dialer Test 1 Dialer Configuration 2 Panel Configuration 2
Job21-08: getting ing Page 4 of 7
Job21-08: getting ing sábado, 30 de junio de 2018 Job Details: FX-350/1/3-126 Series / Dialer
Section Name Value
Account 1 Account ID 123456 Telephone 101 Report Format Contact ID Account 2 Account ID 654321 Telephone 101 Report Format Contact ID Line 1 Dial using tone Yes Wait for dial tone Yes Line 2 Dial using tone Yes Wait for dial tone Yes Report Priority Alarm Account 1 Supervisory Account 1 Trouble Account 1 Timers: AC loss delay 0 Line 2 cellular test No Day of month N/A Auto test at 12:30 a. m. Dialer Line retries 6 Rings 5 Mode UDACT Enable No Aux Disconnect No
Job21-08: getting ing Page 5 of 7
Job21-08: getting ing sábado, 30 de junio de 2018 Input Summary