Example of Concrete Anchor Bolt Design Calculation –
Part­6: Determining Concrete Breakout Strength of
Anchor in Shear
Before diving into the concrete anchor bolt design calculation example for calculating anchor breakout strength in shear,
please go through the problem statement and part­1, part­2, part­3, part­4 and part­5 of this series. The calculation exercise is
carried out according to the ACI 318 appendix D codes.

Calculation

The code gives the following formula for finding out the break out strength in shear for a group of anchor bolts:

φVcbg= φ(AVc/AVco)ψec,V ψed,V ψc,V ψcp,VVb……………………………..D­22

Where,

Φ – Strength reduction factor for breakout strength and its value for non­reinforcement in tension is 0.70

Avc –  projected concrete failure area of the group of anchors, for calculation of strength in shear (in inch2) as approximated
by a rectangle with edges bounded by 1.5*Ca1 (1.5*5 = 7.5 inch in our case) and the free edges of the concrete from the
centerline of the anchors. We will calculate it little later.

Ca1 – Distance from the center of an anchor shaft to the edge of concrete in one direction (in inch). Refer Fig.1 below.

Avco – Total projected shear failure area approximated by a square bounded by 1.5*Ca1 (1.5*5 = 7.5 inch in our case) from
the centerline of a anchor at all the sides. We will calculate it little later.

ψec,V – Modification factor for the anchor group loaded eccentrically in shear, in our case there is no eccentric loading , so
ψec,V=1.

ψed,V – Modification factor for edge effect for the anchor group in shear, we will calculate it later.

Ψc,V – Modification factor based on the presence and absence of crack in the concrete, in our case value of it = 1..

ψcp,V – Modification factor for post weld types of anchor. For cast in place anchor ψcp,V = 1

Vb – Basic concrete break out strength for a single anchor in shear, we will calculate it later.

Calculation of AVc

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 1/6
02/04/2016 Concrete Anchor Foundation Bolt Design Calculations with Example According to ACI 318 Appendix D ­ Breakout Strength in Shear

Fig.1: Showing Ca1 for calculating Avc and Avco for Anchor Group

Fig.2: Anchor Bolt Elevation for calculating Avc

Refer the above two figure (Fig.1 and Fig.2), it should be clear by now that

AVC = 16.5*(5+6+16.5) = 453.75 inch2

Calculation of AVco

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 2/6
02/04/2016 Concrete Anchor Foundation Bolt Design Calculations with Example According to ACI 318 Appendix D ­ Breakout Strength in Shear

Fig.3: Anchor Bolt Elevation for calculating Avco

By referring the above figure (Fig.3), we can calculate

Avco= 16.5*(16.5+16.5) = 544.5 inch2

Calculation of ψed,V

For Ca2 <1.5 Ca1

ψed,V = 0.7+(0.3*Ca2)/(1.5*Ca1) = 0.7+ (0.3*5)/(1.5*11) = 0.79

Where,

Ca2 – Minimum concrete edge distance from anchor perpendicular to Ca1.

Calculation of Vb

Vb=(7*√da*[le/da]0.2 )*λ*√f’c*(Ca1)1.5 ………………………..D­24

Where,

da = Diameter of the anchor bolt in inch., in our case it is 0.75 inch. Remember we have started with the 0.75 inch anchor in
the part­1 of this calculation.

le = Length of the anchor inserted inside the concrete in inch. In our case it is 10 inch.

λ = A factor related to the reduced mechanical properties of concrete, for normal weight concrete λ=1.

Ca1 = we already know it from the Fig.1. Its value is 11 inch.

fc’ = Specified compressive strength of the concrete, in our case fc’=4000 psi (refer problem statement of part­1).

So, by putting all the values, the above equation (D­24) becomes

Vb = (7*√0.75*[10/0.75]0.2)*1*(√4000)*111.5

= 23482.02 lb

Now, from the equation D­22, after putting all the values at right hand side,

φVcbg = φ(AVc/AVco)ψec,V ψed,V ψc,V ψcp,VVb

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 3/6
02/04/2016 Concrete Anchor Foundation Bolt Design Calculations with Example According to ACI 318 Appendix D ­ Breakout Strength in Shear
= 0.7*(453.75/544.5)*1*0.79*1*1*23482.02 lb

= 10821.297 lb

The concrete break out strength in shear for the anchor bolt group according to the ACI codes is calculated as 10821.297 lb.
The next part (Part­7) will talk about Concrete Pullout Strength in Shear.

About Shibashis Ghosh
Shibashis is a mechanical design engineer by profession and writer/blogger by passion. He has worked in
various design projects in automobile, power plant and heavy earth moving equipment domain since 2005.
In his spare time apart from maintaining this blog, he enjoy investing time building his first RC plane 
Read More>>
Find more about me on:

2 2     More

Like this:

 Like
Be the first to like this.

Related

Example of Concrete Anchor Bolt Design Example of Concrete Anchor Bolt Design
Calculation ­ Part­4: Determining Side­face Calculation ­ Part­7: Determining Pryout
Blowout Strength of Anchor in Tension Strength of Anchor in Tension
In this part we will calculate the side­face In this part of the concrete anchor bolt
blowout strength of the concrete anchor design calculation example we will calculate
according to the ACI 318 Appendix D codes the concrete pry out strength under shear
and also consolidate the results of the force applied to the structural cast in place
Example of Concrete Anchor Bolt Design different types of anchor strengths in foundation anchor bolt of the column shown
Calculation ­ Part­2: Determining Concrete In "Engineering design"
tension we have calculated so far. Please In "Engineering design"
in the Figure­1 and 2 of the Part­1 of this
Breakout Strength of Anchor in Tension
In "Engineering design"

3 comments

1. 

asad

September 7, 2013 at 10:48 am (UTC 5.5)

nyc job

2. 

asad

September 7, 2013 at 10:52 am (UTC 5.5)

bt i guess there is some prob with the area calculated for shear for group of anchor.. 
there should be 35 degree leverage to the edge…

3. 

herb

February 8, 2016 at 10:57 pm (UTC 5.5)

Vb=9*1*sqrt 4000* (11)^1.5 =20766 lbs is smaller than 23482lbs as per ACi

Leave a Reply

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 4/6
02/04/2016 Concrete Anchor Foundation Bolt Design Calculations with Example According to ACI 318 Appendix D ­ Breakout Strength in Shear

Enter your comment here...

Anouncement
Science or Engineering Graduate? Write for
mechGuru

Subscribe

To get the latest post directly to your email box, Enter
your email address:

Subscribe

Recent Posts
Do Value Engineering Upfront, Right at Design
Stage
HPDC vs LPDC
Friction welding vs Friction Stir welding
7 Important 3D Printing Technologies – You
Must Know
Automobile Traction Control System Basics and
Application
How Automobile Air Bag System Works?
Why I­Section Beam is structurally better than
same weight other sections?
Micro vs Mild vs Full Hybrid Vehicle
How Chocolates are Made
How LCRV or LSPV Braking System Works
How to calculate vehicle speed from engine
RPM and vice versa
The Challenges of New Eco­Friendly Tech – Are
Electric Cars Really That Green?
Bolted Joint Design Calculation Example for
Joint in Tension
Worst Case Method Assembly Tolerance Stack
up Calculation for Non­Symmetric Dimensional
Tolerances with Example
DFMEA Creation Tutorial with Example

Search

  Search

Sponsors

Place Your Logo Here

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 5/6
02/04/2016 Concrete Anchor Foundation Bolt Design Calculations with Example According to ACI 318 Appendix D ­ Breakout Strength in Shear
Copyright

© 2008­2015

Return to top

Powered by WordPress and the Graphene Theme.

    Copyright Notice  |  Disclaimer  |  Privacy policy  |  Contact

Follow us:

                   

http://blog.mechguru.com/machine­design/example­of­concrete­anchor­bolt­design­calculation­part­6­determining­concrete­breakout­strength­of­anchor­in­sh… 6/6

Вам также может понравиться