IEC SYSTEM FOR CONFIRMITY TESTING

AND CERTIFICATION OF ELECTRICAL COMMITTEE OF TESTING LABORATORIES


EQUIPMENT

IEC 62560:2011
TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING
Self-ballasted LED lamps for general lighting services by voltage > 50 V
Safety specifications
R = Required by Lab
S = May be subcontracted
W = Witness testing
3PPS = Three Phase Power Supply required

Clause Measurement/testing Testing / measuring equipment / material needed Subcontracting


5.2. c) Eye protection Photobiological effects, in accordance with IEC/TR 62471-2 S
5.3 Marking Hexane, water, piece of cloth R
6.1 Cap interchangeability - Table 1 Gauges according to IEC 60061-1 and IEC 60061-3 R

6.2 Bending moment, axial pull and mass Test finger with indicating device and with force meter,
Weighting device R

Standard Test finger (IEC 60529) , IEC 60061-3, sheet 7006-


Protection against accidental contact 51A for E27 caps and sheet 7006-55 for E14 caps, Mega
7 with live parts R
ohmmeter, High Voltage transformer

2011-07-04 1/2 IEC 62560:2011


IEC SYSTEM FOR CONFIRMITY TESTING
AND CERTIFICATION OF ELECTRICAL COMMITTEE OF TESTING LABORATORIES
EQUIPMENT

Clause Measurement/testing Testing / measuring equipment / material needed Subcontracting


Insulation resistance and electric
8.2 - 8.3 strength after humidity treatment Humidity cabinet , Megaohmmeter , High Voltage transformer R
Test holders figures C.1 / C.1.2 and C.2 IEC 60432.1
9.1 - 9.3 Mechanical strength R
10 Cap temperature rise Temperature measuring device, according to IEC 60360 R
Heating cabinet. Ball pressure test apparatus (see also CTL
11 Resistance to the heat D.S. N. 391.mod), timer, digital caliper (or equivalent) R
12 Resistance to flame and ignition Glow-wire test apparatus, timer R
Draught free enclosure, power meter, temp measuring device,
13 Fault conditions high frequency spark generator, mega ohmmeter , voltmeter, R
stopwatch
14 Creepage distances and clearances Digital calliper (or equivalent) R

2011-07-04 2/2 IEC 62560:2011


Nome file: IEC 62560 2011 04_07_2011
Directory: C:\Documents and Settings\parma\Documenti
Modello: C:\Documents and Settings\parma\Dati
applicazioni\Microsoft\Templates\Normal.dotm
Titolo: List of test equipment for IEC 60950 3rd ed.
Oggetto:
Autore: Robert Wunderer
Parole chiave:
Commenti:
Data creazione: 28/12/2010 7.49.00
Numero revisione: 50
Data ultimo salvataggio: 04/07/2011 10.56.00
Autore ultimo salvataggio: parma
Tempo totale modifica 266 minuti
Data ultima stampa: 04/07/2011 10.56.00
Come da ultima stampa completa
Numero pagine: 2
Numero parole: 254 (circa)
Numero caratteri: 1.450 (circa)

Вам также может понравиться