Ld for M40 concrete

Grade of concrete 40 Mpa


Grade of reinforcement fy = 500 Mpa
Bond strength 1.9 Mpa
Bond strength for deformed bar = 3.04 Mpa
σs = 0.87*fy = 435 Mpa
Ld = 35.77 ɸ For compression = 28.618 ɸ

Ld for M35 concrete


Grade of concrete 35 Mpa
Grade of reinforcement fy = 500 Mpa
Bond strength 1.7 Mpa
Bond strength for deformed bar = 2.72 Mpa
σs = 0.87*fy = 435 Mpa
Ld = 39.98 ɸ For compression = 31.985 ɸ

Ld for M30 concrete


Grade of concrete 30 Mpa
Grade of reinforcement fy = 500 Mpa
Bond strength 1.5 Mpa
Bond strength for deformed bar = 2.4 Mpa
σs = 0.87*fy = 435 Mpa
Ld = 45.3125 ɸ For compression = 36.25 ɸ

Ld for M25 concrete


Grade of concrete 25 Mpa
Grade of reinforcement fy = 500 Mpa
Bond strength 1.4 Mpa
Bond strength for deformed bar = 2.24 Mpa
σs = 0.87*fy = 435 Mpa
Ld = 48.55 ɸ For compression = 38.839 ɸ