Structural Analysis Four Storey Residential Building

______________________________________________________________________

Designer:

TULINAO, MARK VINCENT A.

SOAN, BRAIVEN C.

Project: FOUR STOREY RESIDENTIAL BUILDING

Location: KARUHATAN VALENZUELA CITY, PHILIPPINES

DESIGN CRITERIA

Reference Code:

NATIONAL STRUCTURAL CODE OF THE PHIL, Vol. I - 2010 ed.

LOADS:

I. DEAD LOADS (Table 204-2)

a. ROOF Deck

Metal 20 Gage 0.12 kPa

b. WALLS

Exterior Wall 6" CHB 3.45 kPa

Interior Wall (CHB plastered) 1.72 kPa

c. Water Proofing 0.05 kPa

d. Mechanical and Electrical Fixtures 0.20 kPa

e. FLOOR FINISHES

Ceramic or quary tile (20 mm) on 13 mm mortar bed 0.77 kPa

Partition loads 1.00 kPa

f. CEILING Plaster on Wood lath 0.38 kPa


II. LIVE LOADS (Table 205-1)

RESIDENTIAL (4 STOREY)

Basic Floor Area (Residential) 1.9 kPa

Exterior Balconies 2.8kPa

Roof Deck 1.9 kPa

Storage 1.9 kPa

III. EARTHQUAKE LOADS

Seismic Zone 4; Z=0.4 (Figure 208-2A)

Seismic Source Type A (Table 208-6)

Soil Profile Type Sc

Near Source Factor

Na 1.0 (Table 208-4)

Nv 1.0 (Table 208-5)

Seismic Coefficient

Ca 0.4xNa=0.4 (Table 208-7)

Cv 0.56xNv=0.56 (Table 208-8)

IV. DESIGN LOAD COMBINATION

U = 1.4D

U = 1.2D + 1.6L

U = 0.9D + 1.0E

U = 1.2D + 1.0L + 1.0EL

U = 0.5CalD + 1.2D + 1.0L + 1.0E