Вы находитесь на странице: 1из 1

GESTRA Steam Boiler Equipment

GESTRA Steam
SPECTORmodule Boiler according
– for operation Equipment
to EN 12953
SPECTORmodule – for operation according to EN 12953

5 9 1 2 3

14

14
15 13
11 12 13 16 19
°C °F
40
100

1 2 1 3
30
20 80
10 60
0 40
32
-10 20
-20 0
-30 -20
-40 -40

18

19 20

26
27
5

19

7 8
24
25

21
13
9
6

22
17

20 23
19 19
10
19 19
19 19
Condensate Monitoring
Condensate Monitoring
G
B
B
C E
F

A
Type Approvals:
D
D EC approval
TÜV (Germany)

Example of a Steam Boiler Plant Operating without Continuous Supervision (72h)

GESTRA Steam Boiler Equipment Condensate monitoring


1 Low-level limiter of “high-integrity design”: 7 Blowdown flash vessel 17 Strainer A Steam trap with trap test set: test chamber VKE, electrode
level electrode NRG 16-50, level switch NRS 1-50, NRG 16-19 and test station NRA 1-3 for max. 16 traps
SIL 3 8 Residual blowdown cooler 18 Vent valve B Non-return valve RK 86
2 Separate high-level alarm of “high-integrity design”: 9 Automatic intermittent blowdown: 19 Stop valve (also in bypass) Quality control for ingress of foreign matter, using type-
level electrode NRG 16-51, level switch NRS 1-51, intermittent blowdown valve MPA, pilot valve approved systems as per VdTÜV bulletin on water monito-
SIL 3 20 Non-return valve ring facilities (WÜ 100)
10 Blowdown receiver C Monitoring for ingress of acids, blowdown, raw water etc.:
Electrical/pneumatic control valve V 725
819163-00/1211 · © 2011 · GESTRA AG · Bremen · Printed in Germany

3 Level control with high-level alarm and remote water 21


conductivity electrode with integrated resistance thermo-
level indicator: level probe NRG 26-21, level controller 11 Pressure limiter DSF meter LRG 16-9, conductivity switch LRS 1-7
NRR 2-52 and control valve V726 22 Feedwater pump
12 Pressure transmitter DRT D Monitoring for ingress of oil, grease etc.:
4 Water level gauge 23 Monitoring of the feedwater / condensate oil and turbidity detector OR
13 Pressure gauge E Electrical/pneumatic three-way valve for discharging the
5 Conductivity measurement with indicator, conductivity 24 Burner control unit contaminated condensate
limit switch and continuous blowdown control: 14 Safety valve GSV
25 Burner F Condensate tank
conductivity electrode LRGT 16-2, continuous blowdown
controller LRR 1-52, continuous blowdown valve BAE 15 Safety temperature monitor (limiter): resistance G Shutdown of the condensate-return system or interruption
thermometer TRG, temperature switch TRS 5-50, SIL 3 26 Superheater of the safety chain
6 Sample cooler
16 Thermometer 27 Economizer

GESTRA AG Münchener Straße


28215
Str 77, 77
P.O. BoxBremen
D-28215 Bremen
10 54 60, D-28054 Bremen
Telephone
Telefon +49
Telefax
+49 (0)
Telefax +49
(0) 421-35
+49 (0)
421-35 03-0
(0) 421-35
03-0
421-35 03-393
03-393
E-Mail
E-Mail martina.stark@de.gestra.com
Internet
gestra.ag@flowserve.com
Internet www.gestra.de
www.gestra.de