Industrial strength cooling options


for your enclosure from AutomationDirect
Filter Fan Kits
Fan Kits • Easy filter change
• All models are 115V with an expected
service life of 30,000 hours • Outer door lock for outdoor models
• High-performance fan motors and • Impact resistant
finger guards • Weather/UV resistant UL 94V-0 (indoor)/
• Polycarbonate fire retardant plastic grilles, UL94H-B (outdoor)
UL94-V0 • No-screw installation -
• Durable, reusable filter mat included except outdoor models
• Patented “Click and Fit” system allows • Low noise
for rapid filter fan and exhaust filter • 120 VAC and 24 VDC
installation without screws models available

Heat Exchangers
• For NEMA 4 and 4X enclosures
• Closed loop cooling
• Energy efficient: uses approximately the same power as a filtered fan sytem
• 120 VAC and 24 VDC models available

Air Conditioning Units Enclosure Vortex Coolers


• For NEMA 12, 4, 4X type enclosures • For NEMA 12, 4, 4X type enclosures
• Digital temperature controller • Operates on compressed air
• Active condensate evaporation system • Stainless steel construction
• High unit efficiency • No moving parts, no maintenance required
• Tough industrial construction • Vortex coolers can be “resized” for chang-
• Compressor protection system ing applications by simply replacing the
generator inside the cooler. No need to
purchase a new unit
• Replacing the vortex generator takes
minutes

480 VAC
models now
available

Book 3 (14.3)
EN-246 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Enclosure Cooling
HOT HOT
Company
Information

Terminal Blocks
Natural Convection Cooling
Forced Convection Cooling HOT Forced Convection Cooling

Power
Distribution
Blocks

Wiring
Accessories

ZIPLink
COLD COLD Connection
HOT HOT System

Multi-wire
Connectors

Sensor Cables
HOT and Connectors

M12 Junction
Forced Convection Cooling
Vortex Coolers Blocks
Closed Loop Cooling Closed Loop Cooling
Typical Installation:
Mounts into a 3/4” (Filter - not pictured)
Electrical knockout Panel Interface
Connectors
Solenoid Valve
COLD COLD
Wiring Duct

Relief Valves to
Vent Hot Air Compressed
Cable Ties
Air
COLD
Wire
HOT

Bulk
Multi-conductor
Thermostat Cables
HOT HOT
Cold End Muffler

Clean Cold Wire


Air Inside Management
Products

You need to cool down


Closed Loop Cooling
Get the heat out
Power Supplies

DC Converters
Heat inside an enclosure can decrease the life expectancy of How do you get the heat out of your enclosure and away
controlling
COLD units such as your PLC, HMI, AC drives and other from those critical components? There are four basic cooling Transformers
items. Excessive heat can cause nuisance faults from your methods. and Filters

electrical and electronic components: for example, overloads


Circuit Protection
tripping unexpectedly. Heat will also change the expected Natural Convection Cooling
performance of circuit breakers and fuses, which can cause If the ambient temperature outside the enclosure is cooler than Tools
whole systems to shut down unexpectedly. So, if you have any the inside of the enclosure, then the heat can be dissipated Test
electronic equipment or other heat sensitive devices, you may into the atmosphere by radiating it through the surface of the Equipment
needHOT
cooling. enclosure and through the use of louvers or grilles with filters.
Enclosures
What causes all that heat? Forced Convection Cooling
Enclosure
There are basically two sources that can cause the enclosure’s If you have clean and cool ambient air outside of the enclosure, Climate Control
internal temperature to rise above the ratings of the control then a simple forced-air system may be adequate. A system
Safety: Electrical
equipment. such as a filter fan and the associated grille with the appro- Components
priate filter may be an acceptable option.
Internal Sources Safety: Protective

The same items that can be damaged by heat may also be the
Closed Loop Cooling Wear

source of the heat. These include items such as: A system that will keep the ambient air separate from the internal Terms and
Conditions
• Power supplies • Servos enclosure air is needed if the environment is harsh, there are
• AC Drives/inverters • Soft starters wash-down requirements, heavy dust and debris or the presence
• Transformers • PLC systems of airborne chemicals, and the ambient temperature is as high as
• Communication products • HMI systems or higher than the desired internal temperature. Air conditioners
and heat exchangers are examples of closed loop systems.
• Battery back-up systems
Vortex Coolers
External Sources
Vortex coolers create a stream of cold air from a supply of
Other sources of heat that can cause the internal tempera- filtered compressed air. The cold air is injected into the enclo-
ture of your enclosure to rise above a desired level involve the sure, displacing warm air which is exhausted back through the
external enviroment. These include items such as: vortex cooler. While not a closed-loop system, they can be used
• Industrial ovens • Solar heat gain in the same harsh environments since the cold air injected into
• Foundry equipment • Blast furnaces the enclosure is filtered.
Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-247
Prices as of June 29, 2016. Check Web site for most current prices.

Enclosure Cooling –
Selecting a Fan or Air Conditioner
Fan selection Fan Selection Example
To select the proper size (CFM) fan for your forced air cooling A NEMA 12 Hubbell Wiegmann N12302412 enclosure
solution, you need to determine the amount of heat to be (30” high x 24” wide x 12” deep) contains a GS3-2020 AC
removed (in watts) and determine the Delta T (Max. allow- drive (20 HP 230 volt) that has a maximum allowable oper-
able internal enclosure temperature °F – Max. outside ambient ating temperature of 104°F and is located in a warehouse
temperature°F). that has a maximum outside ambient air temperature of 95°F.
CFM = Cubic Feet per Minute
P = Power to be dissipated in watts
Power to be dissipated is stated in the specifications of the
CFM = (3.17 x Pwatts) / Delta T °F GS3-2020 and is found to be 750 watts, so P=750 watts
Delta T = m
 ax. allowable internal enclosure temperature °F – max. Delta T = Max. operating temperature for the GS3-2020 is
outside ambient temperature °F 104°F – Max. ambient air temperature of 95°F
Delta T = 9°F
CFM = (3.17 x 750 watts) / 9°F
CFM = 264
Choose a Hubbell Wiegmann WPF60-115BK filter fan kit
that provides 295 CFM with exhaust kit WPFA50-60BK

Air Conditioner Selection Example


Air conditioner and vortex cooler A NEMA 12 Hubbell Wiegmann N12302412 enclosure
selection (30” high x 24” wide x 12” deep) contains a GS3-4030 AC
drive 30 HP 460 volt) that has a maximum allowable operating
To select the proper size air conditioner or vortex cooler, the temperature of 104°F and is located in a warehouse that has
worst-case conditions should be considered, but take care not a maximum outside ambient air temperature of 115°F.
to choose an oversized unit.
Power to be dissipated is stated in the specifications of the
There are two main factors in choosing an uninsulated metal GS3-4030 and is found to be 1290 watts.
NEMA rated enclosure located indoors:
• Internal heat load Internal heat load:
BTU per Hour = 1290 watts x 3.413
• Heat load transfer
BTU per Hour = 4403 BTU/H
Heat load transfer:
Internal Heat Load
Heat load transfer (BTU/H) = 1.25 x 19 sq. ft. x (115°F – 104°F)
Internal heat load is the heat generated by the components Heat load transfer (BTU/H) = 261.25 BTU/H
inside the enclosure. This can be determined by a few different Cooling capacity:
methods. The preferred method is to add the maximum heat Cooling capacity (BTU/H) = 4403 BTU/H + 261.25 BTU/H
output specifications that the manufacturers list for all the Cooling capacity (BTU/H) = 4664.25 BTU/H
equipment installed in the cabinet. This is typically given in In this example, you are able to determine that a 5000
Watts, so use the following conversion: BTU/H unit is needed. Select a TA10-050-16-12 Stratus air
BTU per Hour = Watts x 3.413 conditioner.
Example: The Watt-loss chart for the GS3 Drives shows that a
GS3-2020 AC drive has a Watt-loss of 750 watts. Note: The same calculation method is used for sizing
BTU per Hour = 750 watts x 3.413 Stratus vortex coolers. However, in this example the
BTU per Hour = 2559 cooling requirements exceed the maximum capacity of
the largest available vortex cooler. If the example
Heat Load Transfer application required the use of a vortex cooler instead
of an air conditioner, two (2) TV35-025-4X units would
Heat load transfer is the heat lost (negative heat load transfer)
be needed.
or gained (positive heat load transfer) through the enclosure
walls with the surrounding ambient air. This can be calculated Thermal
Expansion
by the following formula: Valve
Condenser Evaporator
Heat load transfer (BTU/H) = 1.25 x surface area (sq. ft. ) x (max.
outside ambient air (°F) – max. allowable internal enclosure tem-
perature air (°F))
Surface Area (sq. ft.) = 2 [(H x W) + (H x D) + (W x D)] / 144 sq. inches
Note: 1.25 is an industry standard constant for metal enclosures;
0.62 should be used for plastic enclosures.

Once you have determined your Internal Heat Load and the
Heat Load Transfer, you can choose the proper size unit by Compressor

calculating the needed cooling capacity.


Cooling capacity (BTU/H) = Internal Heat Load ± Heat Load Transfer

Book 3 (14.3)
EN-248 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Enclosure Cooling – Company


Information

Selecting a Heat Exchanger Terminal Blocks

Power
Distribution
Blocks

Heat exchanger selection


Wiring
Heat Exchanger Selection Example Accessories

To select the proper size heat exchanger, the worst-case A NEMA 12 Hubbell Wiegmann N12302412 enclosure (30” ZIPLink
conditions should be considered. For a heat exchanger to high x 24” wide x 12” deep) contains a GS3-4010 AC drive 10
Connection
System
work, the ambient air temperature must be lower than the HP 460 volt) that has a maximum allowable operating tempera-
desired internal enclosure air temperature. ture of 104°F and is located in a warehouse that has a maximum Multi-wire
Connectors
There are three main factors in choosing a heat exchanger outside ambient air temperature of 90°F.
for an uninsulated metal NEMA rated enclosure located Power to be dissipated is stated in the specifications of the Sensor Cables
and Connectors
indoors: GS3-4010 and is found to be 345 watts.
• Internal heat load M12 Junction
• Delta T Blocks

• Heat load transfer Internal heat load:


Panel Interface
Internal Heat Load = 345 Watts Connectors

Internal Heat Load Wiring Duct


Internal heat load is the heat generated by the components Delta T:
Cable Ties
inside the enclosure. This can be determined by a few different ΔT (°F) 104°F – 90°F = 14°F
methods. The preferred method is to add the maximum heat Wire
output specifications that the manufacturers list for all the Heat load transfer:
equipment installed in the cabinet. This is typically given in Surface Area (ft.2) = 2 [(30 x 24) + (30 x 12) + (24 x 12)] / 144 sq. inches
Bulk
Multi-conductor
Watts. = 19 ft.2 Cables

Heat Load Transfer = 0.22 x 19 ft2 = 4.2 Watts/°F


Wire
Management
Delta T (ΔT) Products
Cooling capacity:
Delta T = maximum allowable internal enclosure tempera- Cooling Capacity = 345 Watts/14°F - 4.2 Watts/°F = 20.4 Watts/°F Power Supplies
ture °F – maximum outside ambient temperature °F.
DC Converters
In this example, you are able to determine that a Stratus heat
Transformers
exchanger, with a capacity of at least 20.4 Watts/°F is needed,
Heat Load Transfer and Filters
such as a TE30-030-17-04.
Heat load transfer is the heat lost (negative heat load Circuit Protection
transfer) or gained (positive heat load transfer) through the
enclosure walls with the surrounding ambient air. This can *This selection procedure applies to metal and non-metal, unin- Tools

be calculated by the following formulas: sulated, sealed enclosures in indoor locations. This selection
Test
procedure gives the minimum required size; be careful not to Equipment
Surface Area (sq. ft.) = 2 [(H x W) + (H x D) + (W x D)] / undersize when purchasing.
(144 sq. inches/sq. ft.) Enclosures

Note: Only include exposed surfaces of enclosue in calcu-


Enclosure
lations. Exclude surfaces such as a surface mounted to a Climate Control
wall.
Safety: Electrical
Heat Load Transfer (W/°F) = 0.22 W/°F sq. ft. x surface Components
area
Safety: Protective
Note: Use 0.22 Watts/°F sq. ft. for painted steel and non- Wear
metallic enclosures. Use .10 Watts/°F sq. ft. for stainless
Terms and
steel and bare aluminum enclosures. Conditions

Cooling Capacity
Once you have determined your Internal Heat Load, the
Heat Load Transfer and the Delta T, you can choose the
proper size unit by calculating the needed cooling capacity.
Cooling Capacity (W/°F) = Internal Heat Load / ∆T - Heat
Load Transfer

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-249
Prices as of June 29, 2016. Check Web site for most current prices.

Air Conditioners For NEMA 12


Enclosures
Applications Features
Designed to maintain the tempera- • Digital LED temperature controller with
visible alarm features and 14.2 mm (0.55”)
ture inside an electrical enclosure at numbers
or below a safe level for the enclosed
• Pre-wired for external alarm monitoring
equipment, while maintaining a closed connections (22 AWG three-conductor
loop environment inside the enclosure cable, 7 ft. long)
to keep out contaminates that can be • CFC-free refrigerant
in the ambient air. Can be used in such • Active condensate management system
environments as steel, food processing, • Thermal expansion valve for maximum effi-
petro-chemical, cement, paper/pulp and ciency over wide range of
plastics industries. temperatures and loads
• Fits 12 inch deep enclosures that have
Construction smooth/flat sides. Check enclosure dimen-
sions/specifications before ordering.
• F ree-standing rigid chassis for easy
installation and maintenance • Anti short-cycle compressor protection
• F abricated from 16-gauge cold rolled steel • High and low refrigerant cut-outs with fault
indication
•A  NSI-61 gray polyester powder coating
inside and out • Highly energy-efficient compressors
• P re-cut mounting gasket included, to be • UL/cUL listed
field installed
•A  ll mounting hardware, full-size template
and instruction manual included
Listings
• UL File: SA33404
• Power input terminal block on all models
• UL 50, Type 12
• Made in USA

TA10-060-26-12 shown

Price BTU/Hour Voltage/Hz Running Weight with/without Packaging Max. Ambient Frame
Part Number Amps (lbs) Temp Size
TA10-010-16-12 $1,398.00 120/60 3.44 72/54
1000
TA10-010-26-12 $1,554.00 230/60 2.67 72/54
1
TA10-015-16-12 $1,612.00 120/60 3.89 72/54
1500
TA10-015-26-12 $1,688.00 230/60 2.67 72/54
TA10-020-16-12 $1,698.00 120/60 5.15 87/69
TA10-020-26-12 $1,756.00 2000 230/60 3.07 87/69
TA10-020-46-12 $2,323.00 480/60 1.51 113/95
2
TA10-040-16-12 $1,787.00 120/60 3.76 88/70
125°F (51.67°C)
TA10-040-26-12 $1,841.00 3000 - 4000 230/60 3.07 88/70
TA10-040-46-12 $2,378.00 480/60 0.93 114/96
TA10-050-16-12 $2,058.00 120/60 7.26 107/89
TA10-050-26-12 $2,153.00 5000 230/60 3.76 107/89
TA10-050-46-12 $3,020.00 480/60 1.44 150/132
3
TA10-060-16-12 $2,313.00 120/60 7.83 114/96
TA10-060-26-12 $2,341.00 6000 - 8000 230/60 4.80 114/96
TA10-060-46-12 $3,213.00 480/60 1.80 157/39

* Voltage variation no greater than ± 10% from nameplate rating and Frequency variation no greater than ± 3Hz from
nameplate rating.

Book 3 (14.3)
EN-250 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Air Conditioners For NEMA 4 Company


Information

Enclosures Terminal Blocks

Power
Distribution

Applications Features
Blocks

• Digital LED temperature controller with Wiring


Designed to maintain the temperature inside Accessories
visible alarm features and 14.2 mm (0.55”)
an electrical enclosure at or below a safe numbers
level for the enclosed equipment, while main- ZIPLink
• Pre-wired for external alarm monitoring con- Connection
taining a closed loop environment inside the nections (22 AWG three-conductor cable, 7 System
enclosure to keep out contaminates that can ft. long)
Multi-wire
be in the ambient air. Can be used in such • CFC-free refrigerant Connectors
environments as steel, food processing, • Protective coated condenser coils for
petro-chemical, cement, paper/pulp and corrosion resistance Sensor Cables
and Connectors
plastics industries. • Active condensate management system
M12 Junction
• Thermal expansion valve for maximum effi- Blocks
Construction ciency over wide range of
temperatures and loads
• Free-standing rigid chassis for easy Panel Interface
• Fits 12-inch deep enclosures that have Connectors
installation and maintenance
smooth/flat sides. Check enclosure dimen-
• Fabricated from 16-gauge cold rolled steel sions/specifications before ordering. Wiring Duct
• ANSI-61 gray polyester powder coating inside • Anti short-cycle compressor protection
and out Cable Ties
• High and low refrigerant cut-outs with fault
• Pre-cut mounting gasket installed for NEMA/ indication Wire
UL type rating on all units
• Highly energy-efficient compressors
• All mounting hardware, full-size template and Bulk
instruction manual included • UL/cUL listed Multi-conductor
Cables
• Power input terminal block on all models
Listings Wire
Management
• UL File: SA33404 Products

TA10-060-26-04 shown • UL 50, Type 4 Power Supplies


• Made in USA
DC Converters

Transformers
and Filters

Circuit Protection
Running Weight with/without Max. Ambient Frame
Part Number Price BTU/Hour Voltage/Hz Amps Packaging (lbs) Temp Size Tools

TA10-010-16-04 $1,688.00 120/60 3.44 72/54


Test
1000
TA10-010-26-04 $1,717.00 230/60 2.67 72/54 Equipment
1
TA10-015-16-04 $1,774.00 120/60 3.89 72/54 Enclosures
1500
TA10-015-26-04 $1,842.00 230/60 2.67 72/54
Enclosure
TA10-020-16-04 $1,892.00 120/60 5.15 87/69 Climate Control

TA10-020-26-04 $1,919.00 2000 230/60 3.07 87/69 Safety: Electrical


Components
TA10-020-46-04 $2,469.00 480/60 1.51 113/95
2
TA10-040-16-04 $1,949.00 120/60 3.76 88/70 Safety: Protective
125°F (51.67°C) Wear
TA10-040-26-04 $1,976.00 3000 - 4000 230/60 3.07 88/70
Terms and
TA10-040-46-04 $2,525.00 480/60 0.93 114/96 Conditions
TA10-050-16-04 $2,216.00 120/60 7.26 107/89
TA10-050-26-04 $2,398.00 5000 230/60 3.76 107/89
TA10-050-46-04 $3,149.00 480/60 1.44 150/32
3
TA10-060-16-04 $2,464.00 120/60 7.83 114/96
TA10-060-26-04 $2,490.00 6000 - 8000 230/60 4.80 114/96
TA10-060-46-04 $3,378.00 480/60 1.80 157/139

* Voltage variation no greater than ± 10% from nameplate rating and Frequency variation no greater than ± 3Hz from
nameplate rating.

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-251
Prices as of June 29, 2016. Check Web site for most current prices.

Air Conditioners For NEMA 4X


Enclosures
Applications Features
Designed to maintain the temperature inside • Digital LED temperature controller with visible
alarm features and 14.2 mm (0.55”) numbers
an electrical enclosure at or below a safe
level for the enclosed equipment, while main- • Pre-wired for external alarm monitoring con-
nections (22 AWG three-conductor cable, 7
taining a closed loop environment inside the ft. long)
enclosure to keep out contaminates that can • CFC-free refrigerant
be in the ambient air. Can be used in such
• Protective coated condenser coils for
environments as steel, food processing, corrosion resistance
petro-chemical, cement, paper/pulp and • Active condensate management system
plastics industries.
• Thermal expansion valve for maximum effi-
ciency over wide range of
Construction temperatures and loads
• F ree-standing rigid chassis for easy • Fits 12-inch deep enclosures that have
installation and maintenance smooth/flat sides. Check enclosure dimen-
sions/specifications before ordering.
• F abricated from 16-gauge 304 stainless steel
• Anti short-cycle compressor protection
• P re-cut mounting gasket installed for NEMA/
UL type rating on all units • High and low refrigerant cut-outs with fault
indication
•A  ll mounting hardware, full-size template and
instruction manual included • Highly energy-efficient compressors
• P ower input terminal block on all models • UL/cUL listed

Listings
• UL File: SA33404
• UL 50, Type 4X
TA10-060-16-4X shown
• Made in USA

Running Weight with/without Max. Ambient Frame


Part Number Price BTU/Hour Voltage/Hz Amps Packaging (lbs) Temp Size
TA10-010-16-4X $2,260.00 120/60 3.44 72/54
1000
TA10-010-26-4X $2,288.00 230/60 2.67 72/54
1
TA10-015-16-4X $2,344.00 120/60 3.89 72/54
1500
TA10-015-26-4X $2,369.00 230/60 2.67 72/54
TA10-020-16-4X $2,434.00 120/60 5.15 87/69
TA10-020-26-4X $2,495.00 2000 230/60 3.07 87/69
TA10-020-46-4X $2,998.00 480/60 1.51 113/95
2
TA10-040-16-4X $2,635.00 120/60 3.76 88/70
125°F (51.67°C)
TA10-040-26-4X $2,660.00 3000 - 4000 230/60 3.07 88/70
TA10-040-46-4X $3,210.00 480/60 0.93 114/96
TA10-050-16-4X $2,868.00 120/60 7.26 107/89
TA10-050-26-4X $2,962.00 5000 230/60 3.76 107/89
TA10-050-46-4X $3,598.00 480/60 1.44 150/132
3
TA10-060-16-4X $3,106.00 120/60 7.83 114/96
TA10-060-26-4X $3,131.00 6000 - 8000 230/60 4.80 114/96
TA10-060-46-4X $3,785.00 480/60 1.80 157/139

Book 3 (14.3)
EN-252 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Air Conditioners – Specifications


Company
Information

Terminal Blocks

Power
Stratus Industrial Air Conditioners General Specifications Distribution
Blocks
BTU/H 1000 1500 2000 3000 - 4000 5000 6000 - 8000
95/95 BTU/H Rating 1366 1722 4438 4681 4438 4713 4990 4713 4400 5460 5460 7565 8215 8215 Wiring
Accessories
Rated Voltage (VAC) 120 230 120 230 120 230 480 120 230 480 120 230 480 120 230 480
ZIPLink
Frequency (Hz) 60 Connection
System
Starting Current (4.5 x 22.69 13.77 22.69 13.77 23.42 13.65 5.86 16.42 13.41 4.11 23.42 19.15 9.18 42.41 21.15 10.13
running Amps) Multi-wire
Connectors
Running Current (Amps) 3.44 2.67 3.89 2.67 5.15 3.07 1.51 3.76 3.07 0.93 7.26 3.76 1.44 7.83 4.80 1.80
Sensor Cables
Recommended Fuse Size/ 12 7 12 7 12 7 3 8 6 2 12 10 5 25 12 5 and Connectors
Time Delay (Amps)
M12 Junction
Blocks

Panel Interface
Connection Type Spring cage terminal block 8-24 AWG Spring cage terminal block 6-16 AWG Connectors

Wiring Duct
Ambient Temperature 50° to 125°F (10 to 52°C) Cable Ties
Range
Temp Control Range Programmable digital controller, with 3-digit, 0.55” high, RED LED display Wire
Temp Control Range 70° to 95°F (21° to 35°C)
(Adjustable) Bulk
Multi-conductor
Refrigerant Type R134a R422d Cables

Refrigerant Amount (oz) 12 10.25 9.75 10.25 9.75 10.25 12.5 18 Wire
Management
Refrigerant Flow Control Thermal expansion valve Products
Condensate Management Active condensate evaporation system with safety overflow; barbed fitting for 3/8” ID tubing
Power Supplies
Compressor Type Reciprocating Rotary
DC Converters
Housing Material/Finish NEMA 4 and NEMA 12 units: ANSI 61 gray polyester powder-coated steel housing. NEMA 4x units: 304 Stainless Steel
Atmosphere No corrosive gases or liquids Transformers
and Filters
Agency Approvals UL File: SA33404
* Voltage variation no greater than ± 10% from nameplate rating and Frequency variation no greater than ± 3Hz from Circuit Protection

nameplate rating.
Tools

Air Conditioners Performance Curves


Test
Equipment

Enclosures

TA10-010-26-xx Enclosure
TA10-010-16-xx Climate Control
acity (BTU/H)

2000
Cooling Capacity (BTU/H)

2000
Enclosure air Enclosure air
Temperature 1500 Temperature Safety: Electrical
1500 (oF) (oF) Components
Cooling Capacity

1000 1000 105


105
Safety: Protective
95 500 95 Wear
500
85
85 0
0
Terms and
85 95 105 115 125 85 95 105 115 125 Conditions
Ambient Temperature (oF) Ambient Temperature (oF)

TA10-015-16-xx TA10-015-26-xx
2500
Cooling Capacity (BTU/H)
Cooling Capacity (BTU/H)

2500
Enclosure air
2000 Enclosure air 2000
Temperature
Temperature
1500 (oF)
1500 (oF)

1000 105
1000 105
95
500
95 500
85
85 0
0
85 95 105 115 125 85 95 105 115 125

Ambient Temperature (oF) Ambient Temperature (oF)

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-253
Prices as of June 29, 2016. Check Web site for most current prices.

Air Conditioners Performance Curves

TA10-020-16-xx TA10-020-26-xx
TA10-020-46-xx 7000

pacity (BTU/H)
7000
pacity (BTU/H)

6000 Enclosure air


6000 Enclosure air Temperature
5000
5000 Temperature (oF)
(oF) 4000
4000

Cooling Capacity
3000
Cooling Capacity

105
3000 105
2000 95
2000 95
1000 85
1000 85 0
0
85 95 105 115 125
85 95 105 115 125
Tamb 105 95 85
Ambient Temperature (oF)
Ambient Temperature (oF) 85 6846.067823 6249.77757 4989.576519
95 5626.84892 4989.576519 4703.726037
105 5304.114505 3999.857645 3972.194695
115 4034.692471 2934.321797 2776.540527
125 2973.254837 1997.879715 1810.386388

TA10-040-16-xx TA10-040-26-xx
TA10-040-46-xx
apacity (BTU/H)

7000
pacity (BTU/H)
7000
6000 Enclosure air 6000 Enclosure air
5000 Temperature 5000 Temperature
(oF)
4000
(oF) 4000
Cooling Capacity

Cooling Capacity

3000 105 3000 105


2000 95
2000 95
1000 1000 85
85
0 0
85 95 105 115 125 85 95 105 115 125

Ambient Temperature (oF) Ambient Temperature (oF)

TA10-050-16-xx TA10-050-16-xx
TA10-050-26-xx
TA10-050-46-xx
oling Capacity (BTU/H)
oling Capacity (BTU/H)

8000 8000
Enclosure air Enclosure air
6000 Temperature 6000 Temperature
(oF) (oF)
4000 4000 105
105
2000 95 2000 95
0 85 0 85
Cooling
Cooling

85 95 105 115 125 85 95 105 115 125


Ambient Temperature (oF) Ambient Temperature (oF)

TA10-060-16-xx TA10-060-26-xx
TA10-060-46-xx
Cooling Capacity (BTU/H)

12000
acity (BTU/H)

12000
10000 Enclosure air 10000
Temperature
8000 (oF) 8000 Enclosure air
Temperature
Cooling Capacity

6000 6000 (oF)


105 105
4000 4000
95 95
2000 2000
85 85
0 0
85 95 105 115 125 85 95 105 115 125
A bi
Ambient T
Temperature (oF) Ambient Temperature (oF)

Book 3 (14.3)
EN-254 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Air To Air Heat Exchangers


Consider a Better Construction
Solution: Air to Air Heat • Heat pipe technology
• Closed loop design
Exchanger
• Always closed loop Listings
• Low cost • UL File: SA34086
• E asier to mount on only one side of your • Made in USA
enclosure
• E nergy efficient; uses no more power
than a filtered fan system
Features
• All units are available in NEMA Type 4
• F ilter-free; no diminished cooling capac- and 4X
ity • Available in 120 VAC and 24 VDC
Applications • Motors have a sealed overload protector
• Finned evaporator and condenser
A closed loop cooling system which sections provide a closed loop
employs the heat pipe principle to • Coil systems use aluminum end plates
exchange heat from an electrical and baffles which improve conduction Tall, compact, and deep
enclosure to the outside. and reduce corrosion for longer life. body styles shown
• UL/cUL listed

Air to Air Heat Exchange


The Air to Air Heat Exchanger is a closed loop
cooling system which employs the heat pipe prin-
ciple to exchange heat from an electrical enclo-
sure to the outside. Where ambient temperatures
are suitable for heat pipes, they are the most effi-
cient method of cooling as the waste heat is the
engine which drives the system. The only power
requirement is to operate two circulating fans or
blowers.
Heat pipes have a liquid refrigerant under a
partial vacuum inside sealed tubes. They operate
with a phase change process which is much like
that of mechanical air conditioning, but without
the compressor. Each heat pipe has an evapo-
rator section and a condenser section which are
separated by a permanent baffle so as to provide
a closed loop. The bottom of each heat pipe is in
contact with heated air from the electrical enclo-
sure. When the enclosure air reaches approxi-
mately 75 degrees F., the refrigerant changes to
vapor phase (boils) and the vapor (steam) rises to
the top of the tube which is in contact with cooler
outside (ambient) air.
When the outside air temperature is lower than the enclosure temperature, the refrigerant vapor gives up heat to the outside air
and returns to the liquid phase. It then falls to the bottom and repeats the cycle endlessly so long as there is a negative tempera-
ture differential between the enclosure and outside. Heat pipes will not operate in reverse cycle so heat cannot be transferred
from the ambient to the interior of the enclosure. Although the operation is self limiting, thermostatic control can be used to shut
off the fans when not needed.
The Stratus design has a top-to-bottom enclosure air flow pattern with maximum separation of the inlet and outlet. This design
pulls the hottest air from the top of the enclosure and returns the cooled air from the bottom of the heat pipe to the enclosure.
The air flow on the ambient side is bottom in, top out, so that the hotter discharge air moves up and away rather than being
recirculated.
The units use aluminum end plates and baffles which improve conduction and reduce corrosion for longer life. The center
aluminum baffle, which is swaged into the heat pipe coil, provides an air tight seal between the two air systems.

Book 3 (14.3)
EN-260 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Air To Air Heat Exchangers Company


Information

Specifications Terminal Blocks

Power
Distribution
Blocks

Wiring
Accessories

In this image, a standard In this image, a standard ZIPLink


installation demonstrates Connection
installation shows where the System
dirt and particulate will enter the closed loop condition
the enclosure and be pulled maintained by the Air to Air
in by the fans on your drives Heat Exchanger. Cool air Multi-wire
Connectors
and devices. Filters or not, inlet and outlet vents are
contamination is invited in completely covered by the
by this open loop approach. heat exchanger. This pro- Sensor Cables
vides NEMA type 4 or 4X. and Connectors

M12 Junction
Blocks

Panel Interface
Connectors

Wiring Duct
Stratus Air to Air Heat Exchangers General Specifications
Cable Ties
TE20-015-24D-4X

TE30-030-24D-4X

TE40-050-24D-4X
TE20-015-24D-04

TE30-030-24D-04

TE40-050-24D-04
TE20-015-17-4X

TE30-030-17-4X

TE40-050-17-4X
TE20-015-17-04

TE30-030-17-04

TE40-050-17-04
Wire
Part Number
Bulk
Multi-conductor
Cables

Price $1,028.00 $1,298.00 $1,045.00 $1,315.00 $1,120.00 $1,413.00 $1,145.00 $1,438.00 $1,383.00 $1,608.00 $1,417.00 $1,642.00 Wire
Management
Operating Voltage ± 10%
Products
Range (V)
Power Supplies
Inrush Current (Start 1.92 3.90 1.92 3.90 2.59 9.70
Up Current) (A)
DC Converters
Loading Current 0.37 0.80 0.37 0.80 0.47 1.94
(Running Current) (A) Transformers
and Filters
SCCR (Short Circuit Refer to Footnote 1
Current Rating) (A)
Circuit Protection
Recommended Circuit
Protection Device 1.5 2.5 1.5 2.5 2 6 Tools
Rating (A)
VA Rating (W) 42 20 42 20 56 47 Test
Equipment
Methanol Methanol Methanol Methanol
Refrigerant Type (oz) (0.41) (0.41) (0.81) (1.22) Enclosures
Watts/°C (F°) ­­22 (12) 44 (24) 71.6 (40)
Enclosure
Free Air Flow (CFM) 131 127 131 127 211 235 Climate Control

Weight Without 16 19 32 Safety: Electrical


Packaging (lbs) Components
Body Style compact deep tall
2 2 2 2 2 2 Safety: Protective
CRS with CRS with CRS with CRS with CRS with CRS with Wear
ANSI 61 ANSI 61 ANSI 61 ANSI 61 ANSI 61 ANSI 61
3
Stainless 3
Stainless 3
Stainless 3
Stainless 3
Stainless
Material Type gray
Steel
gray
Steel
gray
Steel
gray
Steel
gray
Steel
gray 3
Stainless Steel Terms and
powder powder powder powder powder powder Conditions
coat coat coat coat coat coat

Voltage/Hz 120 VAC 50/60 24 VDC 120 VAC 50/60 24 VDC 120 VAC 50/60 24 VDC
Maximum Ambient 160°F (71.1°C)
Temperature
Agency Approval UL File: SA34086
1 SCCR rating is based on the SCCR rating for the circuit protection device installed in the panel / enclosure per UL50 and UL508a to protect
the AC unit. Typically 10KA for Fast Acting Fuses.
2 Cold rolled steel with ANSI-61 gray polyester powder coating inside and out.
3 Fabricated from 16-gauge 304 stainless steel.

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-261
Prices as of June 29, 2016. Check Web site for most current prices.

Filter Fan Kits


018000-02
Applications Features
Filter fans provide an optimum • Easy filter change
climate in enclosures. The • Outer door lock for outdoor models
interior temperature of enclo- • Impact resistant
sures is reduced by chan- • Weather/UV resistant UL 94V-0 (indoor)/UL94H-B (outdoor)
neling cooler filtered outside • No-screw installation - except outdoor models
air into the enclosure, thus • Low noise
• 120 VAC and 24 VDC models available
expelling heated internal air.
• Service life - 50,000 hrs@77°F (25°C) + 65%RH
The resulting air flow prevents
• Connection type - 12 to 69 CFM - 2 wires w/case clamps, AWG
formation of localized heat 14, length 4”/136 to 373 CFM - 3 pole terminal, AWG 14, clamping
pockets and protects elec- torque 0.8 Nm
tronic components from overheating. • Airflow direction easily switched by reversing the axial fan
Outdoor filter fans are used in outdoor enclosures where (except on models 018040-01 and 018050-01)
warm air must be dissipated. To clean and exchange the filter • Includes self-adhesive gasket pre-installed on frame
mat, you open the lockable door of the outdoor hood, elimi- • Optional mounting screws for additional support
nating the need to allow interior access to the enclosure. IP55
protection type is achieved due to the special design of the Standards
hood and the use of fine filter mats. All models except outdoor: CE, RoHS, IP55, UL Type 12 when using
supplied filter. For use with NEMA 1 and NEMA 12 enclosures only.
UL #: E234324
Note: Using fine filter mat F5 reduces the airflow. (See Stego Air
Volume and Pressure Data, later in this section.)

Free Air Delivery Max. Operating


Power
Amps Rated Consumption Flow Air Filter Sound Required
Part Price
with Static Temp.
Density
Filtering
Level Cutout
Number (mA) Voltage (60 Hz for Delivery Exhaust Pressure (Max/Min (g/m2) Level
(dB) Sizes
120V models) (CFM)* (CFM)** (Pa)* °F/°C)
Filter Fans
018000-02 $92.00 90 24 VDC 2.2W 12 9 19 31 3.82 x 3.82 inch
(97.03mm x
018000-01 $68.00 160 120 VAC 13W 14 11 18 31 97.03mm)
018010-02 $101.00 210 24 VDC 5W 32 25 32 158/14 °F 40 4.92 x 4.92 inch
(124.97mm x
018010-01 $75.00 180 120 VAC 15W 37 28 30 (70/-10°C) 40 124.97mm)
018020-02 $104.00 210 24 VDC 5W 60 40 23 39
018020-01 $91.00 180 120 VAC 15W 69 46 27 39 6.93 x 6.93 inch
350 94% (176.02mm x
140/-13°F
176.02mm)
018040-01 $156.00 470 120 VAC 39W 136 84 60 (60/-25°C) 52

018030-03 $276.00 840 24 VDC 20W 176 135 23 158/14 °F 53


018030-01 $265.00 700 120 VAC 60W 202 156 27 (70/-10°C) 53 9.84 x 9.84 inch
(249.94mm x
140/-13°F 249.94mm)
018050-01 $218.00 780 120 VAC 85W 373 203 85
(60/-25°C)
52

Outdoor Filter Fans (Rain Hoods)


018210-04 $144.00 210 24 VDC 5W 12 11.8 48 158/14 °F 4.92 x 4.92 inch
360 98% 40 (124.97mm x
018210-02 $123.00 180 120 VAC 15W 14 14 54 (70/-10°C) 124.97mm)
Dimensions in inches (millimeters)

*Fan with filter and louver


**Fan with filter, louver, exhaust filter, and grille.

Book 3 (14.3)
EN-264 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Filter Fan Kits Company


Information

Terminal Blocks

Power
Distribution
Blocks

Wiring
Accessories

Features Standards ZIPLink


Connection
System
• All models are 115V with an expected • cUL Recognized/CSA fan motor
service life of 30,000 hours • NEMA 1 (NEMA 12 with optional Multi-wire
• High-performance fan motors and WPFG series gasket) Connectors
finger guards • IP43 (IP54 with optional WPFG
• Polycarbonate fire retardant plastic Sensor Cables
Series gasket) and Connectors
grilles, UL94-VO
• Durable, reusable filter mat included
• Patented “Click and Fit” system allows
Accessories M12 Junction
Blocks

for rapid filter fan and exhaust filter • Gaskets (WPFG  Series)
recommended Panel Interface
installation without screws Connectors
Applications (This time-saving feature cuts instal-
lation time by up to 30 minutes when
if installing on enclosure with
textured finish Wiring Duct
• Most innovative technology for fan compared to traditional box fan pack- • Replacement Filters
cooling and pressurizing of industrial ages) (WPFM Series) Cable Ties
enclosures.
• Cutout template provided with every
• Provides a high quality, economical unit Wire
method of cooling enclosures
• Filter fan or exhaust filter simply snaps
• Filtered passive ventilation can be Bulk
into cutout opening Multi-conductor
provided by an exhaust filter for either Cables
convection cooling or in combination • Connector type: WPF10 Series 2 has
with a fan in forced air cooling 12-inch wires. WPF20-WPF60 Series
has terminal strip. Wire
• Slim line design allows grille to pro- Management
Products
trude from enclosure surface less than
one quarter inch Power Supplies
• Maintains aesthetics of enclosure
DC Converters

Transformers
and Filters

Circuit Protection

Tools

Test
Equipment
Free Air Ambient
Amps at Delivery Max.
Power Flow Air Temp. Filter Sound Required Enclosures
Rated Static Filtering
Part Number Price 50/60
Voltage
Consumption with
Press.
Degree Density
Level
Level Cutout
Hz at 50/60 Hz Delivery Exhaust F Max/ (G/M2) (dB) Sizes Enclosure
(PA)
(CFM)1 (CFM)1 Min
Climate Control

3.62x3.62 Safety: Electrical


WPF10-115BK $194.00 0.15/0.15 115V 12/12 Watts 16 10 29 140/14 150 67% 39
(92x92) Components

4.92x4.92
WPF20-115BK $250.00 0.25/0.25 115V 19/19 Watts 38 28 69 122/14 350 83% 49
(125x125)
Safety: Protective
Wear
8.78x8.78
WPF25-115BK $342.00 0.25/0.25 115V 18/18 Watts 89 62 57 122/14 350 83% 53
(223x223) Terms and
Conditions
8.78x8.78
WPF30-115BK $435.00 0.5/0.5 115V 43/44 Watts 169 142 89 122/14 350 83% 55
(223x223)
11.46x11.46
WPF50-115BK2 $461.00 0.6/0.7 115V 63/76 Watts 324 249 205 122/14 350 83% 69
(291x291)
11.46x11.46
WPF60-115BK2 $517.00 1.2/1.6 115V 122/173 Watts 410 295 225 122/14 350 83% 71
(291x291)
Note 1: For operation at 50Hz, reduce CFM by 15%.
Note 2: Intake fan use only
Dimensions in inches (millimeters)

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-273
Prices as of June 29, 2016. Check Web site for most current prices.

Vortex Coolers Company


Information

Terminal Blocks
Features How vortex coolers
• Relief valves and seals built into the
vortex coolers which enable the units create cold air Power
Distribution
Blocks
to maintain the sealed nature of NEMA Compressed air is injected into the
enclosures. vortex tube at extremely high speeds Wiring
• No freon Accessories
and that creates a cyclone, or vortex,
• Small physical size spinning a million revolutions per ZIPLink
Connection
• Creates cool air without refrigerants minute. Part of the air is forced to spin System
(no CFCs, HCFCs) inward to the center and travels up
• Exceptionally reliable - no moving parts a long tube where a valve turns the Multi-wire
and virtually no maintenance Connectors
spinning column of air inside itself.
• No fans The inside column of air gives up its Sensor Cables
• Stainless steel construction heat to the outside column. The cold and Connectors

• All replacement generators fit any of air is directed out the cold end of the M12 Junction
the vortex coolers. No need to purchase Vortex Tube and the hot air is directed Blocks
a new cooler if you need to change your out the other end of the Vortex Tube.
cooling capacity. Panel Interface
And since there are no moving parts Connectors
• 5-year warranty
there is little need for maintenance.
Requirements Wiring Duct

• Uses clean, dry, oil-free compressed air Cable Ties


(80 to 100 PSIG / 70 degrees F or below)
Applications required to achieve published BTU/H
ratings. Lower pressures and/or higher
Wire

Compressed air cooling is used where temperatures will reduce BTU/H rating Bulk
Multi-conductor
conventional enclosure cooling by • A 5 micron water and particulate Cables
air conditioners or heat exchangers removal filter must be installed prior to
is not possible. (Examples: Small to any vortex cooler operation. Wire
Management
medium size enclosures, nonmetallic • An oil removal filter can be installed Products
enclosures, and areas where the size of between the 5 micron filter and the
Vortex Cooler if oil is present in the Power Supplies
cooling devices is restricted) compressed air line.
• Thermostats, filters and valves that DC Converters
Mounting holes work with Stratus Vortex Coolers are
sold separately and listed later in this Transformers
• Mounts in a 3/4” electrical conduit section. and Filters
knockout
• Operation above 100 PSIG is not Circuit Protection
recommended. The use of a pressure
regulator will be necessary for higher Tools
pressures.
Capacity  Air Consumption  Test
Part Type Part Number Price Description Equipment
BTU/H [KCAL/H] SCFM [SLPM]
Stratus vortex cooler, 500 BTUH (147W) / 8 SCFM (227 SLPM), stainless steel Enclosures
TV08-005-4X $270.00
body. For NEMA 4/4X/12 enclosures. Distribution tube and muffler included.
500 [126] 8 [227]
Enclosure
Stratus vortex cooler, 600 BTUH (176W) / 10 SCFM (283 SLPM), stainless Climate Control
TV10-006-4X $270.00 steel body. For NEMA 4/4X/12 enclosures. Distribution tube and muffler 600 [151] 10 [283]
included. Safety: Electrical
Stratus vortex cooler, 1000 BTUH (293W) / 15 SCFM (425 SLPM),
Vortex Components
TV15-010-4X $270.00 stainless steel body. For NEMA 4/4X/12 enclosures. Distribution tube and 1000 [252] 15 [425]
Coolers muffler included.
Safety: Protective
Stratus vortex cooler, 1800 BTUH (528W) / 25 SCFM (708 SLPM), Wear
TV25-018-4X $270.00 stainless steel body. For NEMA 4/4X/12 enclosures. Distribution tube and 1800 [454] 25 [708]
muffler included.
Terms and
Stratus vortex cooler, 2500 BTUH (732W) / 35 SCFM (991 SLPM), Conditions
TV35-025-4X $270.00 stainless steel body. For NEMA 4/4X/12 enclosures. Distribution tube and 2500 [630] 35 [991]
muffler included.
Stratus vortex generator, replacement, 500 BTUH (147W) / 8 SCFM
TV08-G $7.00
(227 SLPM), polypropylene, white. For all Stratus TV series vortex coolers.
500 [126] 8 [227]

Stratus vortex generator, replacement, 600 BTUH (176W) / 10 SCFM


TV10-G $7.00
(283 SLPM), polypropylene, orange. For all Stratus TV series vortex coolers.
600 [151] 10 [283]

Replacement TV15-G $7.00


Stratus vortex generator, replacement, 1000 BTUH (293W) / 15 SCFM
1000 [252] 15 [425]
Generators (425 SLPM), polypropylene, red. For all Stratus TV series vortex coolers.

Stratus vortex generator, replacement, 1800 BTUH (528W) / 25 SCFM


TV25-G $7.00
(708 SLPM), polypropylene, blue. For all Stratus TV series vortex coolers.
1800 [454] 25 [708]

Stratus vortex generator, replacement, 2500 BTUH (732W) / 35 SCFM


TV35-G $7.00
(991 SLPM), polypropylene, yellow. For all Stratus TV series vortex coolers.
2500 [630] 35 [991]

Book 3 (14.3)
www.automationdirect.com/enclosures Enclosures Thermal Management EN-279
Prices as of June 29, 2016. Check Web site for most current prices.

Vortex Coolers
Part Type Part Number Price Description
Stratus taper sleeve, replacement, brass. For all Stratus TV
TVACC-TS $12.00
series vortex coolers.
Replacement Stratus distribution tube, replacement, flexible PVC, 8ft.
TVACC-TUBE $8.00
Parts For all Stratus TV series vortex coolers.
Stratus muffler, replacement, polypropylene. For all Stratus
TVACC-MUFFLER $10.00
TV series vortex coolers.

Assembly

Dimensions in [mm]

Book 3 (14.3)
EN-280 Enclosures Thermal Management 1-800-633-0405
Prices as of June 29, 2016. Check Web site for most current prices.

Vortex Cooler Kits


Requirements How vortex coolers
• Uses clean, dry, oil-free compressed
air (100 PSIG / 70 degrees F or below) create cold air
required to achieve published BTU/H Compressed air is injected into the
ratings. Lower pressures and higher vortex tube at extremely high speeds
temperatures will reduce BTU/H
ratings. and that creates a cyclone, or vortex,
• A 5-micron water and particulate spinning a million revolutions per
removal filter must be installed prior to minute. Part of the air is forced to
any vortex cooler operation. spin inward to the center and travels
• An oil removal filter can be installed up a long tube where a valve turns the
between the 5 micron filter and the spinning column of air inside itself. The
Vortex Cooler if oil is present in the inside column of air gives up its heat
compressed air line.
to the outside column. The cold air is
NEMA 4/4X NEMA 12 directed out the cold end of the Vortex
Mounting holes Tube and the hot air is directed out
Applications • NEMA 12: (1) 1-3/32” (28mm) or 3/4”
knockout hole for cooling tube and (1)
the other end of the Vortex Tube. And
since there are no moving parts there
Compressed air cooling is used where 11/16” hole for thermostat
is little need for maintenance.
conventional enclosure cooling by • NEMA 4 and 4X: (1) 1-15/16” (49mm) or
air conditioners or heat exchangers 1-1/2” knockout hole for cooling tube
is not possible. (Examples: Small to and (2) #8 holes for thermostat
medium size enclosures, nonmetallic
enclosures, and areas where the size of Includes the
cooling devices is restricted).
following:
• Vortex cooler
Features • Vortex distribution tube
• Suitable for harsh environments
• Solenoid valve 120V / 60Hz - 110V /
• Small physical size 50Hz
• Creates cool air without refrigerants • Filter: 5-micron water and particulate
(no CFCs, HCFCs) removal
• Exceptionally reliable - no moving parts • Ducting kit
and virtually no maintenance
• Thermostat

Standards
• UL Listed
• NEMA 12, NEMA 4 or NEMA 4X

Enclosure Shipping Schedule


Same day 1 - 7 days
Color indicates shipping lead time in business days.

Capacity Air Consumption


Part Number Price Description BTU/H [KCAL/H] SCFM [SLPM]
Hubbell-Wiegmann vortex cooler, 400 BTUH (117W) / 8 SCFM (227 SLPM), aluminum body. For
W750400 $831.00
NEMA 12 enclosures. Thermostat, solenoid valve, distribution tube and filter included.
400 [101] 8 [227]
Hubbell-Wiegmann vortex cooler, 900 BTUH (264W) / 15 SCFM (425 SLPM), aluminum body. For
W740900 $1,024.00
NEMA 12 enclosures. Thermostat, solenoid valve, distribution tube and filter included.
900 [225] 15 [425]
Hubbell-Wiegmann vortex cooler, 1500 BTUH (440W) / 25 SCFM (708 SLPM), aluminum body. For
W7901500 $1,024.00
NEMA 12 enclosures. Thermostat, solenoid valve, distribution tube and filter included.
1500 [378] 25 [708]
Hubbell-Wiegmann vortex cooler, 1700 BTUH (498W) / 25 SCFM (708 SLPM), aluminum body. For
W7971700 $1,020.00
NEMA 4 enclosures. Thermostat, solenoid valve, distribution tube and filter included.
1700 [425] 25 [708]
Hubbell-Wiegmann vortex cooler, 1700 BTUH (498W) / 25 SCFM (708 SLPM), stainless steel body.
W797SS1700 $1,656.00 For NEMA 4/4X enclosures. Thermostat, solenoid valve, distribution tube and filter included.
1700 [425] 25 [708]

Book 3 (14.3)
EN-282 Enclosures Thermal Management 1-800-633-0405