Obtaining Oil Sample for Analysis{1302, 1348, 3030, 3080,
3278, 4011, 4070, 5050, 5056, 5095, 7542}
Número de medio -SEBF8482-04Fecha de publicación -24/03/2009Fecha de actu

i03547304

Obtaining Oil Sample for Analysis{1302, 1348,


3030, 3080, 3278, 4011, 4070, 5050, 5056, 5095,
7542}
SMCS - 1302; 1348; 3030; 3080; 3278; 4011; 4070; 5050; 5056; 5095;
7542

Agricultural Tractor: All


Articulated Truck: All
Asphalt Paver: All
Backhoe Loader: All
Challenger: All
Cold Planer: All
Combine: All
Compact Track Loader: All
Compact Wheel Loader: ALL
Earthmoving Compactor: All
Excavator: All All Wheeled Excavators
Forest Products: All
Integrated Toolcarrier: All
Landfill Compactor: All
Load Haul Dump: All

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 2 de 28

Mini Hydraulic Excavator: All


Motor Grader: All
Multi Terrain Loader: All
Off-Highway Truck/Tractor: All
Paving Compactor: All
Pipelayer: All
Road Reclaimer/Soil Stabilizer: All
Skid Steer Loader: All
Soil Compactor: All
Telehandler: All
Track Feller Buncher: Caterpillar
Track-Type Loader: All
Track-Type Skidder: All
Track-Type Tractor: All
Underground Articulated Truck: All
Wheel Dozer: All
Wheel Feller Buncher: All
Wheel Loader: All
Wheel Skidder: All
Wheel Tractor-Scraper: All

Introduction
This Guideline enables dealers and the dealer's customers to benefit from
cost reductions which were made possible through an established
Contamination Control Program. Fluids that are used in Caterpillar
machines are highly effective unless the fluid contains damaging amounts
of contaminates. Therefore, every effort must be made in order to reduce
the contamination level within Caterpillar fluid systems. Caterpillar makes
ongoing changes and improvements to the Caterpillar products. This
guideline must be used with the latest technical information available from
Caterpillar in order to ensure that such changes and improvements are
incorporated when applicable.

For questions or additional information concerning this guideline, submit a


feedback form in the Service Information System website. In order to
address an urgent need, please use the following to relay your request to
Caterpillar Repair Process Engineering:

 Cat Dealer Technical Communicator

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 3 de 28

 Dealer Solution Network

 Cat Technical Representative

 Knowledge Network (on-line)

If a Contatmincation Control Guideline is required, but not available in SIS


Web, submit a feedback form in the Service Information System website.

Summary
A good oil sample that accurately represents the condition of the fluid
system is vital for the success of any analysis program. For this reason,
the oil should be at the system operating temperature or at least 50 °C
(120 °F) if the normal operating temperature cannot be reached when
the sample is taken. The following guideline describes the methods in
order to obtain oil samples from machine fluid systems. Bottle sampling
(pressure and suction) and portable particle counter methods are included in
this guideline. These processes are used when an oil sample is taken or
when an on-line particle count is taken on any fluid system (such as
hydraulic, steering, power train, engine and final drive).

References
Table 1
References
Media
Title
Number
Valve Installation for Scheduled Oil Sampling of Engine,
SEHS9043
Transmission, Hydraulics, and Steering
PEVN4831 Count on Caterpillar Particle Analyzers
Tool Operating Manual for S40 Portable Particle
NEHS0799
Analyzer
PEEP5031 Oil Analysis Bottle Label

NOTICE

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 4 de 28

Keep all parts clean and keep all parts free of


contamination.

Hot oil and hot components can cause personal


injury. Do not allow hot oil or hot components to
contact the skin.

On-line Particle Counting using S·O·S Valves


Table 2

Parts List
Quantity Part Number Parts Description
1 162-5791 Shop Towel
1 170-8500 S40 Particle Counter
1 210-5530 Quick Disconnect

1 (1) GE06L1/4NP TA3C Male Connector


1 188-0639 Hose as Replacement Parts
( 1 ) These items can be obtained by contacting Caterpillar Capital Tooling Group. A
proper fitting will be provided at no cost.

Illustration 1 g01281548

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 5 de 28

170-8500 Pama On-line Particle Counter

Note: Refer to Contamination Control Guideline, PEVN4831, "Count on


Caterpillar Particle Analyzers" and refer to Tool Operating Manual,
NEHS0799, "Manual for S40 Portable Particle Analyzer" for proper
installation and operation. Caterpillar recommends to connected the on-line
particle counters directly to the S·O·S valve.

Note: Refer to the Operation and Maintenance Manual for the S·O·S valve
locations. Refer to the Test and Adjust Manual in order to obtain the system
pressures. Prepare all equipment used to sample oil in advance in order to
prevent contamination prior to taking a sample.

Illustration 2 g01281550
Left - high pressure hose, Right - low pressure hose

1. Determine the fluid system pressure at the location where the sample is
to be taken (S·O·S valve). For proper supply hose and hardware refer
to Contamination Control Guideline, PEVN4831, "Count on
Caterpillar Particle Analyzers" and refer to Tool Operating Manual,
NEHS0799, "Tool Operating Manual for S40 Portable Particle
Analyzer".

2. Exercise the machine until the sampled fluid system is up to the


normal operating temperature or at a minimum of 50 °C (120 °F).

3. Park the machine on level ground. Lower all of the attachments.


Engage the parking brake.
4. Set the engine at low idle. All systems must be in a safe position.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 6 de 28

Illustration 3 g01281551
S·O·S valve dust cover

5. Remove the dust cover from the S·O·S valve. Refer to the Operating
and Maintenance Manual for the S·O·S valve locations.

Illustration 4 g01281552
162-5791 Lint Free Towel . Transmission S·O·S valve shown.

6. Clean the S·O·S valve with a clean 162-5791 Lint Free Towel .

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 7 de 28

Illustration 5 g01281553
210-5530 Quick Disconnect

7. Make sure that the 210-5530 Quick Disconnect is clean.

Illustration 6 g01281554
Typical particle counter supply hose attached to the S·O·S valve (low pressure
hose shown)

8. Attach the particle counter supply hose to the S·O·S valve.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 8 de 28

Illustration 7 g01281555
Particle counter connections

9. Secure the particle counter's discharge hose with a catch basin.

10. If the sampled fluid system has cooled down, exercise the machine
until the sampled fluid system is up to normal operating temperature or
a minimum of 50 °C (120 °F).

NOTICE
Do not move the machine while the particle counter
in connected. Moving the machine in this condition
could cause damage to the machine and/or the
particle counter.

Note: Allow power train circuits to idle for a minimum of ten minutes
prior to particle counting. This will allow entrapped air to escape from
the sampled oil. Air trapped in the oil will distort the particle counter
readings.

11. Operate the particle counter according to the manufacturer's


instructions in order to obtain an oil sample reading.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 1348, ... Página 9 de 28

Illustration 8 g01281556
Remove sampling hoses.

12. After testing, disconnect the particle counter hose assembly from the
machine. After testing, disconnect the hose assembly from the particle
counter. Drain the hoses. Cap all the hose ends. Store the particle
counter and store the hoses in a clean location.

Illustration 9 g01281557
Replace dust cap

13. Install the dust cap onto the S·O·S valve. Make sure that the cap is

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 10 de 28

clean on the inside.


14. Properly dispose of any waste oil.

Bottle Sampling Using Oil Valve Probe and


S·O·S Valve
Table 3

Parts List
Quantity Part Number Part Description
1 162-5791 Shop Towel
2 169-8373 Sample Bottle Group
1 162-8873 Sample Bottle Probe Holder
1 8T-9208 Probe Assembly (1)
1 4C-4600 Sample Bottle Shipping Container
( 1 ) Purging with tube

Hot oil and hot components can cause personal


injury. Do not allow hot oil or hot components to
contact the skin.

Note: Refer to Operation and Maintenance Manual for the S·O·S valve
locations. Refer to the Test and Adjust Manual in order to obtain the
system pressure. Only perform a bottle sample when the system pressures
are below 3450 kPa (500 psi). Prepare all equipment used to sample oil and
protect the equipment from contamination.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 11 de 28

Illustration 10 g01281558
S·O·S mailing label

1. Fill out the S·O·S label. Pay special attention to the serial number,
sample data, service meter units on the equipment, service meter units
on the oil, oil type, oil brand and the amount of oil added. Indicate if
the oil was changed after the sample was taken.

Illustration 11 g01281559
Sample bottle package

2. Open the 169-8373 Sample Bottle package. Remove the sampling


probe tube from the bag.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 12 de 28

Illustration 12 g01281560
Probe holder and probe

3. Insert the open sampling probe tube into and through the 162-8873
Sample Bottle Probe Holder counter bored end. Pull the probe tube all
the way through the holder until the sampling needle seats in the
holder.

Illustration 13 g01281561

4. Remove the sampling bottle from the package. Install the cap with two
holes onto the bottle. Install the probe tube into one of the holes in the
cap.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 13 de 28

Illustration 14 g01281562

5. Return the assembled bottle and return the probe back into the package
in order to prevent contamination.

6. Exercise the machine until the system oil to be sampled is up to normal


operating temperature or at a minimum of 50 °C (120 °F).

7. Park the machine on level ground. Lower all the attachments. Engage
the parking brake.

8. Set the engine at low idle. Make sure that all systems are in safe
positions. Refer to the Operation and Maintenance Manual.

Illustration 15 g01281564

9. Remove the dust cover from the S·O·S valve.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 14 de 28

Illustration 16 g01281565

10. Clean the S·O·S valve with a clean 162-5791 Lint Free Shop Towel .

Illustration 17 g01281566
Purging S·O·S valve with 8T-9208 Purge Probe and tube

11. Purge the S·O·S valve by pressing the 8T-9208 Purge Probe onto the
S·O·S valve. Purge a minimum of one sample bottle of oil or more if it
is required to ensure that all the dead volume of the fluid is purged and
the sampling nipple is internally cleaned.

Note: If the oil flow is slow at low idle, it may be necessary to have
someone accelerate the engine.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 15 de 28

Illustration 18 g01281567
Oil disposal

12. Properly dispose of the purged oil.

Illustration 19 g01281568
Prepared bottle sample

13. Remove the prepared sample bottle from the package.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 16 de 28

Illustration 20 g01281576
Flush sample bottle

14. Rinse the sample bottle and rinse the probe tube with the system oil.
Rinse the bottle by filling the bottle half full with the system oil.

Illustration 21 g01281577
Flush sample bottle

15. Shake the sample bottle vigorously for several seconds.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 17 de 28

Illustration 22 g01281578

16. Then empty the oil into a waste oil container.

Illustration 23 g01281579

17. Fill the sample bottle to the "fill range" imprinted on the bottle, but do
not fill beyond the fill mark.

Note: Do not fill the bottle beyond the fill mark. Filling beyond the
fill mark will not allow for proper lab mixing.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 18 de 28

Illustration 24 g01281580

18. Remove the sampling probe tube from the bottle lid. Save the knurled
probe holder and discard the probe tube.

Illustration 25 g01281581

19. Immediately replace the two-hole lid on the sample bottle with the
solid lid (no hole). Dispose of the lid with two holes.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 19 de 28

Illustration 26 g01281583

20. If it is necessary, clean the outside of the bottle.

Illustration 27 g01281585
Mailing tube with completed label

21. Place the bottle with the completed information label into a 4C-4600
Shipping Container or take the bottle and label to the lab.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 20 de 28

Illustration 28 g01281586

22. Wipe any oil off the sample valve.

Illustration 29 g01281588

23. Install the dust cap onto the S·O·S valve and check that the cap is clean
on the inside.

Zero Pressure System Using a Hand Vacuum


Pump

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 21 de 28

Table 4

Parts List
Quantity Part Number Part Description
1 162-5791 Shop Towel
2 169-8373 Sample Bottle Group
1 1U-5718 Oil Sampling Vacuum Pump
1 4C-4600 Sample Bottle Shipping Container
1 1U-7648 Tube Cutter
1U-8757 Tube

Hot oil and hot components can cause personal


injury. Do not allow hot oil or hot components to
contact the skin.

Note: Typical nonpressurized systems are reservoirs, differentials, final


drives, or return lines (drains). The sample location should be near the
middle of the reservoir's fluid level and away from the sidewall. The
sample location should be where the fluid is normally in motion,
thoroughly mixed, and at normal operating temperature. The sample should
be taken as soon as possible after the machine exercising has been stopped.
Prepare all sampling hardware before an oil sample is taken.

Note: Never use the same vacuum pump for obtaining both oil and coolant
samples. Although the fluid does not enter the barrel of the pump, a small
residue of glycol from the coolant remains in the pump and can
contaminate the oil sample. This will indicate a "false positive" coolant leak
in the oil system being sampled.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 22 de 28

Illustration 30 g01281590

1. Fill out the S·O·S label. Pay special attention to the serial number,
sample data, service meter units on equipment, service meter units on
oil, oil type, oil brand and the amount of oil added. Indicate if the oil
was changed after the sample was taken.

Illustration 31 g01281591
1U-8757 Tube cut to length

2. Measure the tubing and then cut new 1U-8757 Tubing to the length of
the dipstick. If there is no dipstick, cut the tubing so that the tubing
reaches about halfway into the oil depth of the compartment being
sampled.

Note: Use a 1U-8757 Tube Cutter in order to prevent the tubing from
being contaminated.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 23 de 28

Illustration 32 g01281593

3. Install tubing into the 1U-5718 Vacuum Pump . The bottle end of the
tubing should be approximately 25.4 mm (1 inch) beyond the base of
the vacuum pump head.

Illustration 33 g01281594

4. Install a new bottle to be sampled to the vacuum pump.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 24 de 28

Illustration 34 g01281595

5. Store the vacuum pump assembly and store the clean bottle cap in the
plastic bag until the parts are ready for use.

6. Exercise the machine fluid to be sampled until the fluid system is up to


normal operating temperature. If normal operating temperature cannot
be reached, then 50 °C (120 °F) is acceptable.

7. Park the machine on level ground. Lower all the attachments. Engage
the parking brake.

8. Shut the machine off. Make sure that all the systems are in safe
positions. Refer to the Operation and Maintenance Manual.

Illustration 35 g01281596

9. Clean the sample location using a clean 162-5791 Lint Free Shop
Towel .

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 25 de 28

Illustration 36 g01281597

10. Keep the sample bottle vertical when taking samples. Pump the
vacuum pump handle in order to create a vacuum.

Note: If the bottle is tilted, the oil will enter into the suction of the
barrel of the vacuum pump. This will cause cross contamination of
subsequent samples.

Illustration 37 g01281598

11. Fill the sample bottle half full with system oil.

12. Remove the bottle from the vacuum pump.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 26 de 28

Illustration 38 g01281577

13. Install a clean lid and shake the bottle vigorously for several seconds.

Illustration 39 g01281578

14. Empty the bottle into a waste oil container.

15. reinstall the sample bottle to the vacuum pump.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 27 de 28

Illustration 40 g01281599

16. Take the oil sample in the same manner. Fill the bottle to the "fill
range".

Note: Do not fill the bottle beyond the fill mark. This will not allow
for proper lab mixing.

Illustration 41 g01281583

17. When the oil bottle is filled, remove the bottle from the vacuum pump.
Cap the bottle with a clean lid (no holes).

18. Clean the outside of the bottle.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisw... 02/10/2010
Búsqueda del medio - SEBF8482 - Obtaining Oil Sample for Analysis{1302, 134... Página 28 de 28

Illustration 42 g01281585

19. Place the bottle with the completed information label into a 4C-4600
Shipping Container or take the bottle and the label to the lab.

20. Remove the tubing from the vacuum pump and discard the tubing in
the probe location.

Illustration 43 g01281596

21. Clean any covers, caps, plates, etc that have been removed.

Copyright 1993 - 2010 Caterpillar Inc. Sat Oct 2 15:30:03 EST 2010