UT-3000: Gaslaufplan

optische Zelle

10 l/h 40 l/h
Measurement of Total Gaseous Mercury in Air or Other Gases GoldTrap
V2

at Ultratrace Levels V1
Pumpe
Massenfluss-
Sensor
Nullluft-
Filter

0,45 µm Kalibrier-
PTFE-Filter Septum

Probengas-Eingang

UT-3000: Flow diagram

Optical Cell

10 l/h 40 l/h
GoldTrap V2
V1
Pump
Mass flow
meter

The UT-3000 Mercury UltraTracer provides a compact and reliable tool for measuring mercury in Zero air
filter

gases at ultra trace levels. Utilizing the high performance0.45


GoldTrap
µm amalgamation module and an
Calibration
PTFE filter port
optimized state-of-the-art AA-mercury vapor detector the UT-3000 Ultra-Tracer offers detection
Sample in
limits at sub-ng/m³ (ppq-parts per quadrillion) levels.

Automatic Operation tion line of the Hg atoms measured. The reference beam
method is applied to get an exceedingly high stability of
UT-3000: Ablauf eines Messzyklusses
The UT-3000 operates automatically. All functions are the UV source. The mercury concentration is measured
Nullpunkt Zelle spülen
controlled by an embedded microprocessor. Once the in an optical cell which has been made entirely of fused
Sammeln Heizen Reinigen
analysis has been started, measurements are performed silica (Suprasil).
and data are collected by the built-in datalogger. With
standard settings the datalogger has a recording capacity Thanks to the sensitivity enhancement
Kühlen provided
Kühlen by the

of 5000 measurements. GoldTrap there is no need for a long path cell which
always has a greater surface effect. Recent solid state UV
detectors with subsequent digital signal processing are
GoldTrap Amalgamation System used for absorption measurement.

For use in the UT-3000 a new trapping system has been


developed: the Mercury GoldTrap, which is one of the UT-3000: Steps of a measurement cycle
key components of the system. It consists of a wafer thin Zeroing Purge Cell

ceramic tube which has been carefully crafted to achieve Sampling Heating Trap Cleaning

minimum thermal inertia. The tube has been packed


with ultrapure gold and supports a heating coil on its Trap Cooling Trap Cooling
outside. The Mercury GoldTrap reveals sharp and high
peaks and an excellent long-term stability. As air is used
for purging the trap during the heating step, possible
contaminations are oxidized and swept off thus prevent-
Sampling
ing from passivation. It is essential that the trap is free of mercury before sam-
pling. This is ensured by a cleaning step which is auto-
Atomic Absorption Detector matically performed.
The detector used in the UT-3000 provides a maximum To keep particles out of the system and to protect the
of sensitivity, precision and stability. A high frequency
trap from passivation, a filter is installed upstream the
driven electrodeless mercury low pressure lamp is used
sample inlet. The filter is made of low-interactive mate-
as UV light source.
rial; the filter membrane has a porosity of 0.45 µm and
It generates a 253.7 nm emission line of an extremely is made of PTFE. The complete filter unit is easily replace-
narrow bandwidth which is congruent with the absorp- able.
Sample Flow Control The type of syringe used for this purpose is specially
designed to measure and dispense gases. The mercury is
The sample flow is measured with a high precision elec- then automatically drawn onto the GoldTrap. Calibration
tronic mass flow meter. The flow rate integrated over gas sources are available as accessories. The calibration
time gives the total sample volume. The flow is auto- check procedure can be automatized as an option.
matically changed to a lower value during the desorption
step to achieve maximum sensitivity.
Display and Output of
Measurements
Calibration
The results of the measurements are displayed on a
There are two methods to check and calibrate the instru- graphic LCD as a bargraph and numerically. It is pos-
ment: sible to view past readings with a paging function.
Calibrations are
One way is to capture mercury on the GoldTrap by bub-
stored in a non-
bling air through a liquid mercury standard to which
volatile memory. The
stannous chloride solution has been added.
device has a serial
Another quick, accurate, and precise way is the static interface for data
calibration with mercury saturated air. Gaseous mercury transfer to a PC and
is injected directly onto the GoldTrap. In this case the a 4-20 mA output.
built-in calibration port is used which is internally con-
nected to the sample gas line leading into the GoldTrap.
The calibration port is equipped with a septum through Advantages of the AA Detection
which gaseous mercury is injected with a syringe.
Method
The latest AA detection technique used in the UT-3000
offers some clear advantages over other methods.
Mercury trace detection by fluorescence must use a car-
rierUT-3000:
and sometimes
Gaslaufplana sheath gas and suffers from the
quenching effect which can never be completely elimi-
nated. optische Zelle

10 l/h
The UT-3000 requires
GoldTrap no expensive gases for operation
40 l/h
V2
and there are no negative
V1
interferences caused by the
quenching effect. Sensitivity and Pumpe
detection limits are far
Massenfluss-
superior to those instruments based on measurement Sensor of
UT-3000 Mercury UltraTracer Nullluft-
with Automatic Calibration Unit electrical resistivity of a thin
Filter gold film.

0,45 µm Kalibrier-
PTFE-Filter Septum

Probengas-Eingang

How does the UT-3000 work?


The Mercury Instruments GoldTrap is used to cap-
ture total gaseous mercury (TGM) directly from the UT-3000: Flow diagram

atmosphere. GoldTraps work because mercury sticks


to gold at room temperature. A gas carrying gaseous Optical Cell

mercury is pulled through the trap; the gas contin- 10 l/h 40 l/h
GoldTrap
ues to flow through the trap but the mercury stays V2
V1
behind–trapped on the gold.
Pump
Mass flow
meter
After the mercury is captured, the GoldTrap is heated Zero air
filter
very quickly; this releases the mercury as a gas (ther-
Calibration
mal desorption). The gaseous mercury is then swept 0.45 µm
PTFE filter port

by the flow of purified mercury free air into the opti-


Sample in
cal cell of the detector. Here the mercury is measured
by atomic absorption spectrometry.

UT-3000: Ablauf eines Messzyklusses


Nullpunkt Zelle spülen

Sammeln Heizen Reinigen