•Features
1. Excellent for use in the circuit of miniature portable equipment for
over-current protection.
2. Available, 0603~1206 sizes, with overall height of 0.6mm.
3. No smoke, no flame, at the fusing conditions.
4. Certificated to meet UL and c-UL.
•File No.: E176847
•Dimensions
L
W
d d
Unit : mm
Style Metric Inch L W H c d *Unit weight/pc.
NEW FCC16 +0.15
1608 0603 1.6±0.1 0.8 −0.05 0.45±0.10 0.3±0.15 0.3±0.1 2mg
NEW FHC16
FCC20
2012 0805 2.0±0.1 1.25±0.10 0.6 ±0.1 0.4±0.2 0.4±0.2 6mg
NEW FHC20
FCC32 3216 1206 3.2±0.2 1.6 ±0.15 0.6 ±0.1 0.5±0.25 0.5±0.25 10mg
• 0402 size is also available. Please contact KAMAYA for further information. *Values for reference
•Example
Parts Number Description
Style
FCC 20 202 AD TP
24
KAMAYA OHM
1.25A
0.63A
1.25A
0.4A
0.5A
0.8A
1.0A
1.6A
2.0A
2.5A
0.5A
0.8A
1.0A
1.6A
2.0A
FCC16 AD FCC16 AB
100 100
10 10
Fusing Time(s)
Fusing Time(s)
1 1
0.1 0.1
0.01 0.01
0.001 0.001
0.1 1 10 100 0.1 1 10 100
Fusing Current(A) Fusing Current(A)
3.15A
2.5A
4.0A
FHC16 AD FHC16 AB
100 100
10 10
Fusing Time(s)
Fusing Time(s)
1 1
0.1 0.1
0.01 0.01
0.001 0.001
0.1 1 10 100 0.1 1 10 100
Fusing Current(A) Fusing Current(A)
25
KAMAYA OHM
1.25A
0.5A
0.8A
1.0A
1.6A
2.0A
2.5A
FCC20 AD
100
10
Fusing Time(s)
0.1
0.01
0.001
0.1 1 10 100
Fusing Current(A)
3.15A
1.25A
4.0A
1.0A
1.6A
2.0A
2.5A
FHC20 AD FHC20 AB
100 100
10 10
Fusing Time(s)
Fusing Time(s)
1 1
0.1 0.1
0.01 0.01
0.001 0.001
0.1 1 10 100 0.1 1 10 100
Fusing Current(A) Fusing Current(A)
26
KAMAYA OHM
1.25A
0.5A
0.8A
1.0A
1.6A
2.0A
2.5A
FCC32 AD
100
10
Fusing Time(s)
0.1
0.01
0.001
0.1 1 10 100
Fusing Current(A)
•Derating Curve
The derated values of current for temperatures in excess of 70°C shall be indicated by the following Curve.
100
Percentage of the rated current(%)
0
-55 70 125
Ambient Temperature(°C)
•Performance Characteristics
Description Requirements Test Methods IEC 60127-4
Carrying capacity No fusing Rated current × 110%, 70°C, 1h.
Bend strength of the
face plating No visible damage Clause 8.3 1mm/s, amount of bend : 3 mm
Solderability At least 95% of the terminal surface must be covered by new solder Clause 8.5 Be immersed into solder at 235°C for 2s.
Resistance to soldering
heat No visible damage. Meet electrical requirement Clause 8.7 Be immersed into solder at 260°C for 10s.
Clause 9.4 At normal condition.
Endurance The voltage drop shall not have increased by more
Rated current ×1.05, 1h"ON", a quarter"OFF",100 cycles.
(rated load) than 10% of the value measured before the test
Rated current ×1.25, 1h.
Temperature rise on the Clause 9.7.5 Test will be conducted at the highest temperature rise of the
surface 70°C max. element before 5min from Endurance test over.
Note. Please contact KAMAYA regarding the case of special usage.