Redundant function is most popular in ESD (Emergency shut Down) type application. Usually these products are part of the
shut down loops and connected to an independent shut down control system which may be Double or Triple redundant.
Depending on the application demand, three types of redundant systems are in use:
1.) 1 Out of 2 type voting system for high safety loops where in tripping of any of the switching circuit will trip the application.
This is typically required for critical circuits where in failure to shut down safely can have catastrophic consequences.
2.) 1 Out of 2 type voting System for high demand loops requiring high uptime avoiding spurious trips due to equipment mal
functions. These types of systems are called for in mission critical application where in equipment failure can result in heavy
losses for plant.
3.) 1 Out of 3 type voting system combining high demand and safety in system using Triple Redundant control systems to
ensure safety and high uptime. These types of system are installed on most critical operations in highly hazardous process
Industries.
ROTEX is in a position to offer solutions for all of the above conditions using a Redundancy in Operator type principle which
essentially combines independent Valve operating components arranged in redundant configurations. This concept is most
superior to the Redundancy in Solenoid since it makes the complete valve component redundant to each other reducing the
probability of failure of these valves. The system, essentially a single block solution, eliminates all interconnecting point
leakage thereby increasing reliability and ensuring trouble free operation.
Especially for pilot operated solenoid valves, ROTEX offers a solution using Redundant operators in application requiring
high availability of equipment to avoid spurious tripping. These are classified as Valves with Redundant Operators.
10
ROTEX can also offer the Redundant Solenoid valves with In build Non Contact type switches to test the system availability
for shutdown.
MEDIA
Air, Inert Gases, Water, Oil
APPLICATION
ESD application where spurious
tripping due to power failure to the
solenoid/ valve malfunction can
cause great damage to the safety of
the equipment/ material being
processed
10
SPECIFICATION
PRE- SOLENOID ENCLOSURE
(LPM OF WATER @ 1 bar ΔP)
REFERENCE NUMBER
CONNECTION AND INTERNALS OVERRIDE VA
bar PROOF PROOF
PILOT PRESSURE
FLOW FACTOR kv
CONSTRUCTION
ORIFICE (mm)
VALVE TYPE
SOLENOID SIZE
IS WITH CIRCUIT
Exia IIC T6, IP 67
STAYPUT CUM
SS 316/ CF8M
FLYING LEAD
MOMENTARY
AC HOLDING
ALUMINIUM
AC INRUSH
F.Silicon
Viton GLT
MAXIMUM
AMMONIA
MINIMUM
OXYGEN
BRASS
BSP(F)
NPT(F)
EPDM
Viton
SIZE
FPJB
NBR
NIL
DC