KEY PLAN:

1- GENERAL NOTES 6-CONCRETE MIXED & PLACING


FORMWORK 01 10 20 30 40 50 60 70 80 85

1-1 ALL STRUCTURAL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH ARCHITECTURAL AND ELECTROMECHANICAL 6-1 - TYPE OF CEMENT AS PER AC1-318 SECTION 3.2
DRAWINGS AND RELATED SPECIFICATIONS. - ORDINARY PORTLAND CEMENT ( TYPE-I ) FOR GENERAL PURPOSE 1- CONCRETE LINES IN DRAWINGS. 4- BLINDING CONCRETE A A1 A2 B1 B2 C1 C2 D1 D2 G1 G2 H1 H2
- TYPE II TO RESIST TO ALKALI ATTACK OR EXPOSED TO WEATHER E'
1-2 DO NOT SCALE FROM DRAWINGS. ALL DIMENSIONS SHOULD BE READ OR COMPUTED. - TYPE V FOR ALL BURIED CONCRETE & ACCORDING TO THE GEOTECHNICAL REPORT RECOMMENDATIONS.
RESERVATION
H C3 C4 D3 D4
-UNDER FOUNDATIONS (UNLESS NOTED OTHERWISE)
K'
N E1 E2 F1 F2
1-3 ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED. 6-2 UNLESS OTHERWISE SPECIFIED, THE MINIMUM 28 DAYS CYLINDRICAL COMPRESSIVE STRENGTHS ARE:

75mm
- BLINDING/LEAN CONCRETE......................................f'c=20 MPa
BEAM T E3 E4 F3 F4
1-4 BLINDING AND LEAN CONCRETE TO BE PROVIDED UNDER FOOTINGS PILE CAPS ACCORDING TO SPECIFICATIONS AND - COLUMNS, RETAINING WALL ...................................f'c=50 MPa
DETAILS.
- FOOTINGS,SLABS & BEAMS.......................................f'c=40 MPa
BLINDING CONCRETE V I1 I2 I3 I4
A A
1-5 NO BACKFILLING SHALL BE PERFORMED BEFORE CASTING THE SLABS THAT SUPPORT RETAINING WALLS.
6-3 ALL CONCRETE SHALL BE MOIST FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS IMMEDIATELY
AFTER POURING BY THE USE OF WET BURLAP, FOG SPRAYING OR OTHER APPROVED METHODS. OPENING
5- TYPICAL DETAIL AT GENERAL EXCAVATION LIMIT
1-6 ALL PLANS ARE SEEN FROM ABOVE.
6-4 CONCRETE SHALL BE POURED IN ITS FINAL POSITION WITHOUT SEGREGATION, RE-HANDLING OR LEGEND:
1-7 BEFORE POURING ANY CONCRETE, THE CONTRACTOR SHOULD FIX ALL RESERVATIONS, SLEEVES, ELECTRICAL TUBES,
FLOWING. NO CONCRETE SHALL POURING BE ALLOWED WITHOUT THE USE OF VIBRATORS, UNLESS AUTHORIZED IN
PIPES, ETC.., AS INDICATED ON ELECTRO-MECHANICAL DRAWINGS AND SPECIFICATIONS. 1 LIMIT OF EXCAVATION
WRITING BY THE DESIGNERS.
1.5
1-8 ALL INSERTS FOR ELECTROMECHANICAL EQUIPMENTS, GENERATORS,HVAC, PUMPS, LIFT, STEEL WORKS TRADES ETC... COLUMN
SHALL BE COORDINATED WITH THE RELATED SUPPLIER/CONTRACTOR AND EMBEDDED IN THE FORMWORK BEFORE
PLAN VIEW
POURING OF CONCRETE AND TO THE ENGINEER'S SATISFACTION.
7-REINFORCED CONCRETE OPENING
1-9 TYPICAL DETAILS AND SECTIONS SHALL APPLY WHERE SPECIFIC DETAILS ARE NOT SHOWN ON THE DWGS.
6- PILE & PILE CAPS TYPICAL DETAILS C
L
UNLESS NOTED ON DRAWINGS, THE FOLLOWING IS TO BE CONSIDERED AS TYPICAL AND APPLICABLE:
1-10 ALL CONSTRUCTION MATERIALS TO WHICH REFERENCE IS MADE IN THE DRAWINGS AND IN THE TYPICAL DETAILS SHALL
CONFORM TO THE AMERICAN STANDARDS ASTM FOR CONSTRUCTION AND TO THE SPECIFICATIONS
7-1 BASIS OF DESIGN: THE ACI CODE PILE CAP REINFORCEMENT
SLAB COLUMN REINFORCEMENT
1-11 ALL CONSTRUCTION SHALL CONFORM TO THE AMERICAN BUILDING CODE IBC 2009 UNLESS OTHERWISE NOTED. SEE SLAB ON GRADE
7-2 ALL CONCRETE REINFORCEMENT SHELL HAVE A YIELD STRENGTH OF 420 MPa VAR SLAB ON GRADE
REINFORCEMENT
1-12 ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE GENERAL REQUIREMENTS OF THE DRAWINGS, THE GENERAL
7-2 PARTICULAR CARE SHOULD BE GIVEN TO THE PLACING OF REINFORCEMENT, THE MIXING AND CASTING OF CONCRETE,
CONDITIONS AND THE SPECIFICATIONS.
AND ACCORDING TO THE SPECIFICATIONS FOR THIS TRADE.
SECTION A-A
1-13 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO ACQUAINT HIMSELF AND ALL SUPERVISORY PERSONNEL 25mm THK. CEMENT SCREED
7-3 CONCRETE POURS SHALL PREFERABLY BE CONTINUOUS BETWEEN JOINTS.
WITH THE ABOVE-NAMED DRAWINGS AND DOCUMENTS. PROTECTION LAYER
50 50
7-4 THE MINIMUM CONCRETE PROTECTIVE COVER FOR REINFORCEMENT SHALL BE AS FOLLOWS:

50x∅

50x∅
H
ELASTOMERIC WATER 75mm THK.
-GRADE BEAMS: 40 mm BLINDING CONCRETE
1-14 THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING THE SITE OF THE PROPOSED WORK TO SATISFY HIMSELF PROOFING SHEET
-FOR COLUMNS: 40 mm
AS TO THE EXISTING CONDITIONS RELATIVE TO THE CONTRACT. 100mm THK. BLOCK WALL
-FOR BEAMS: 40 mm
ELASTOMERIC WATER
-FOR INTERNAL WALLS NOT EXPOSED TO WEATHER : 25 mm
1-15 THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. IF
ANY UNDERGROUND UTILITIES FOUND DIFFERENT THAN LOCATED, THEY SHALL BE PROTECTED IN PLACE AND THE
-FOR EXTERNAL WALLS EXPOSED TO WEATHER : 40 mm 2- SYMBOLS PROOFING SHEET
-FOR WALLS EXPOSED TO EARTH: 50 mm
ENGINEER SHALL BE IMMEDIATELY NOTIFIED. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE OF ANY AND ALL
-WATER TANK WALLS: 50 mm COLUMN C
DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL
-FOR SOLID SLABS: 25 mm WALL W 25mm THK. CEMENT SCREED
UNDERGROUND UTILITIES.
-FOR SLAB ON GRADE: 40 mm BEAM B PROTECTION LAYER
-FOR FOOTINGS: 75 mm DOUBLE RIB DR
1-16 THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DRAWINGS FOR SETTING OUT LEVELS, GROOVES, CLIPS, 75mm THK.
MOULDS, ORNAMENTS AND OTHER EMBEDDED ITEMS TO BE CAST INTO CONCRETE. REFERENCE MUST ALSO BE MADE TO JOIST J BLINDING CONCRETE
7-5 FOR ALL ELECTROMECHANICAL RESERVATIONS IN WALLS, SLABS AND BEAMS, EXACT LOCATION TO BE COORDINATED WITH GRADE BEAM GB
MECHANICAL & ELECTRICAL DRAWINGS FOR EMBEDDED ITEMS, PIPE SLEEVES, EQUIPMENT PADS AND OPENINGS NOT
ELECTROMECHANICAL DRAWINGS. THICKNESS TH
SHOWN ON STRUCTURAL DRAWINGS. ALL OPENINGS SHALL BE FORMED OR SLEEVED BEFORE PLACING CONCRETE.
CONTRACTOR SHALL ALSO PROVIDE ALL NECESSARY INSERTS, TIES, CLIPS, ANCHORS, STRAPS, HANGERS, AND OTHER EXPANSION JOINT EJ
FASTENING DEVICES AS REQUIRED BY REFERING TO SPECIALTIES DRAWINGS. NO PIPES, DUCTS, CONDUIT, SLEEVES ETC.
7-6 OPENINGS SMALLER THAN 150mm MAY BE FORMED EITHER BY BOXING OUT OR BY CAREFUL DRILLING BY CORE CONSTRUCTION JOINT CJ TYPICAL WATER PROOFING DETAIL
CUTTER AFTER CASTING.
SHALL BE CAST INTO STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED AND APPROVED BY THE ENGINEER. BOTTOM BOT. FOR PILE CAPS & SLAB ON GRADE
CLEAR CLR
7-7 ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED AND SPACED IN FORMS AND CONCRETE LEVEL C.L. UNDER NATURAL SOIL LEVEL
SECURED IN PLACE IN ACCORDANCE WITH THE PROCEDURES AND REQUIREMENTS OUTLINED IN THE LATEST EDITION OF C
2- LOADS ASSUMPTIONS THE "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", ACI 318 AND THE "MANUAL OF STANDARD PRACTICE
DETAIL
DIAMETER
DET

L

FOR DETAILING REINFORCED CONCRETE DRAWING(S) DWG(S) PILE CAP REINFORCEMENT COLUMN REINFORCEMENT
2-1 DEAD LOAD: SELF WEIGHT OF THE STRUCTURAL COMPOMENTS SUCH AS SLABS, EXCAVATION LEVEL E.L.
7-8 ALL CONSTRUCTION JOINTS SHALL BE WIRE BRUSHED AND CLEANED IMMEDIATELY PRIOR TO POURING NEW FLOOR FL SEE SLAB ON GRADE SLAB ON GRADE
COLUMNS,BEAMS...ETC, BASED ON A UNIT WEIGHT OF CONCRETE 25 KN/m3 PARTITIONS AND CLADDING LOADS ARE AS PER CONCRETE,THE SURFACE OF THE CONCRETE AT ALL JOINTS SHALL BE ROUGHENED MINIMUM 6mm,THOROUGHLY CLEANED VAR
ARCHITECTURAL DRAWINGS. MISCELLANEOUS MISC REINFORCEMENT
AND ALL LAITANCE REMOVED PRIOR TO PLACING ADJOINING CONCRETE.
NATURAL GRADE LEVEL NGL
2-2 LIVE LOAD: NOT TO SCALE NTS
7-9 THE SEQUENCE OF POURING CONCRETE SHALL BE SUCH AS TO MINIMIZE SHRINKAGE.
-PUBLIC AREAS AND COMMERCIAL AREAS INSIDE THE AIRPORT WITH HIGH OCCUPANCY, UNIFORM OPENING OPNG
LIVE LOADS = 5KN/m², SOLID SLAB SS
7-10 ALL REINFORCEMENT SHALL BE CONTINUED ACROSS CONSTRUCTION JOINTS UNLESS NOTED OTHERWISE
CONCENTRATED LIVE LOAD : 10KN APPLIED ON 150 mm x 150 mm TYPICAL TYP 50 50

50x∅

50x∅
H
-UNLESS OTHERWISE STATED, THE LOADING FOR THE TECHNICAL ROOMS ON FLOORS WILL 7-11 PROVIDE 1 LAYER OF 250 MICRON POLYETHYLENE SHEET VAPOR RETARTER UNDER SLAB ON GRADE VAPOUR RETARDER VAPOUR RETARDER
BE AT LEAST 5KN/m2 AND 10KN/m2 ON GRADE SLAB, THIS LIVE LOAD INCLUDES THE WEIGHT
OF MATERIAL AND THE REAL LIVE LOAD 7-12 REINFORCING STEEL TO BE BENT AND PLACED IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE FOR DETAILING
3- JOINTS MIN 150mm THK. ELASTOMERIC WATER 100mm THK. BLOCK WALL
MIN 150mm THK.
COMPACTED TO MINIMUM 95%
-ROOF LIVE LOAD FOR INACCESSIBLE ROOF WILL BE AS FOLLOWS: CONCRETE STRUCTURES (ACI 315-CURRENT EDITION)".. COMPACTED FILL PROOFING SHEET STANDARD PROCTOR DENSITY
-FOR ROOF AREA < 100m² = 1.2KN/m² & MAX 120KN REINFORCEMENT CARRIED

75 25
-FOR ROOF AREA > 100m² = 0.58KN/m² 7-13 MAXIMUM AGGREGATE SIZE TO BE 20mm. THROUGH JOINT
-A COMPLEMENTARY LIVE LOAD DUE TO SAND ACCUMULATION OF 0.5KN/m² IS CONSIDERED. 100
7-14 PROVIDE CONTINUOUS KEYWAYS AT RETAINING WALL CONSTRUCTION JOINTS. 25mm THK. CEMENT SCREED

EQ. EQ. EQ.


2-3 WIND LOAD: ACCORDING TO ASCE-7-10 PROTECTION LAYER

75 25 THICKNESS
-BUILDING CATEGORY IS III 7-15 ALL REINFORCING STEEL SHALL BE SECURELY WIRED IN PLACE BEFORE CONCRETE IS PLACED.
1st STAGE KEY 2nd STAGE 75mm THK.
-IMPORTANCE FACTOR IS I=1.15

t=
7-16 MAXIMUM SPACING OF BAR SUPPORTS IN SLAB ON GRADE TO BE 1200mm. BLINDING CONCRETE
-SITE EXPOSURE D
-BASIC WIND SPEED 45m/s (162 Km/h)
7-17 DRILLING IN BEAMS AND COLUMNS FOR MOULDING INSTALLATION OR ANY OTHER PURPOSE, SHOULD BE DONE WITH
2-4 SEISMIC LOAD: ACCORDING TO IBC 2009 EXTREME CARE TO AVOID CUTTING ANY OF THE STEEL REINFORCING. LOCATE BARS AND STIRRUPS BEFORE ANY TYPICAL WATER PROOFING DETAIL
-IMPORTANCE FACTOR: I=1.25 DRILLING.THE CONTRACTOR SHALL PROVIDE INFORMATION ON HIS PROCEDURE IN WRITING TO STRUCTURAL ENGINEER FOR PILE CAPS & SLAB ON GRADE
-SITE CLASS D BEFORE ANY DRILLING. PROTECTION CEMENT SCREED
-0.2 SEC SPECTRAL ACCELERATION, Ss = 0.092 VAPOR RETARDER
ABOVE NATURAL SOIL LEVEL
-1 SEC SPECTRAL ACCELERATION, S1 = 0.037 7-18 FOR ONE WAY SLAB, BARS ALONG SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONGER SPAN AT
CENTER AND OVER THE LONGER SPAN BARS NEAR THE SUPPORT UNLESS OTHERWISE INDICATED OR SHOWN IN DETAILS. BLINDING CONCRETE
C
L
2-5 TEMPERATURE VARIATION: CHANGE
-FOR EXTERNAL ELEMENTS ±30°C TYPICAL MAT CONSTRUCTION JOINT DETAIL COLUMN REINFORCEMENT
-FOR INTERNAL ELEMENTS ±25°C b a SLAB ON GRADE GRADE BEAM SLAB ON GRADE
SLAB ON GRADE

3- FOUNDATION NOTES 8- STRUCTURAL NOTATIONS WATER STOP


POLYSTYRENE
SEALANT
SECTION MARK 1
3-1 PILE FOUNDATION ARE USED TO SUPPORT THE STRUCTURES. (TO BE CONFIRMED BY THE GEOTECHNICAL REPORT) ADDED LINK BARS ADDED LINK BARS

50x∅ 50x∅

50x∅ 50x∅

50x∅ 50x∅
(EXAMPLE: SECTION 1) VAPOUR RETARDER
#12@200 #12@200
3-2 PILES AXIAL CAPACITIES AND LENGTH ARE INDICATED IN PILES & PILES CAPS SCHEDULES DRAWINGS. 100mm THK. BLOCK WALL
SLAB TOP CONCRETE LEVEL
3-3 TOTAL NUMBER OF PRELIMINARY AND WORKING PILE LOAD TESTS ON EACH PILE DIAMETER SHOULD
BE AS PER PROJECT BILL OF QUANTITIES. SECTION b-b
TH=400mm
EXPANSION JOINT

50x∅

50x∅

50x∅
H
3-4 SONIC LOGGING TESTS SHOULD BE CARRIED OUT FOR 10% OF THE TOTAL NUMBERS OF PILES OF FOR WALL AND SLABS
SLAB THICKNESS (WHERE INDICATED)
DIAMETER 600 mm, 800 mm & 1000 mm TOTAL NUMBER OF SONIC LOGGING TESTS SHOULD BE AS PER
PROJECT BILL OF QUANTITIES REVISION:
STIRRUPS SIZE AND NUMBER & SPACING: ST10@50 4x100 Rx200 ELASTOMERIC WATER PILE CAP
PROOFING SHEET
3-5 LOW STRAIN INTERGRITY TEST SHOULD BE CARRIED OUT ON ALL THE PILES. TOTAL NUMBER OF
SLOT FILLED

75 25
LOW STRAIN INTERGRITY TESTS SHOULD BE AS PER PROJECT BILL OF QUANTITIES. READ AS: #10 Stirrup, FIRST spaced @50mm, 4 Spaced @100mm, Remaning @200mm PILE CAP
WITH A SEALING COMPOUND 8 50xBAR DIAMETER
3-6 A PROPER DEWATERING SYSTEM IS TO BE DESIGNED TO LOWER THE GROUND WATER DAWN NUMBER OF BARS 10 # 20 @200 L=10000 50% CONTINUOUS
50% SPLICED

25
AT LEAST 0.5m BELOW THE PROPOSED EXCAVATION LEVELS.
DEWATERING WORKS ARE TO REMAIN IN OPERATION UNTIL SUFFICIENT DEAD LOADS IS APPLIED BY THE INDICATE HIGH YIELD (GRADE 60) STEEL
PERMANENT SUB STRUCTURE TO PROVIDE AN APPROPRIATE FACTOR OF SAFETY AGAINST UPLIFT
BAR DIAMETER
H PILE
3-7 THE SOIL SUPPORTING FOUNDATION ( OR SLAB-ON-GRADE) SHALL BE COMPACTED TO 95% MAXIMUM DRY
DENSITY AT OPTIMUM MOISTURE CONTENT. BAR SPACING c/c
150

TO PERFORM FIELD DENSITY TEST IN ACCORDANCE WITH ASTM D1556 OR ASTM D2167.
BAR LENGTH VAPOUR BARRIER
b a GRADE BEAM & PILE CAP SECTION a-a A 15/12/2015 ISSUED FOR CONSTRUCTION - MODIFICATIONS IF ANY ARE CLOUDED J.M.L
3-8 ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND ACCEPTABLE GRANULAR FILL COMPACTED 95% OF MAX. DRY DATE
DENSITY SHALL BE USED FOR BACKFILLING. COMPACTED TO MINIMUM 95% TYPICAL CONNECTION DETAIL REV. (dd/mm/yy) DESCRIPTION OF REVISION APP.
STANDARD PROCTOR DENSITY
3-9 REFER TO MECHANICAL DRAWINGS FOR UNDERFLOOR PIPES, PITS, DRAINAGE SYSTEM AND SPECIAL GRANULAR
GROUND SLAB & UPPER SLAB NOTE
FILL MATERIALS REQUIRED. TYPICAL SLAB ON GRADE CONSTRUCTION JOINT DETAIL PILE CAP ELASTOMERIC WATER PROOFING SHEET

3-10 THE CONTRACTOR SHOULD TAKE ALL MEASURES AND PRECAUTIONS NECESSARY TO PREVENT ANY DAMAGE TO
(MAXIMUM SPACING BETWEEN JOINTS = 10.00m) 15mm OF EPOXY GROUT NAME DATE (dd/mm/yyyy)

50x∅
EXISTING BUILDING FOUNDATIONS OR FACILITIES, IF ANY, ADJACENT TO PROJECT, INCLUDING TO EXISTING SLAB THICKNESS IN mm Th= 350 DESIGNED BY:
25mm AVERAGE THICKNESS A.KORJIEH 15/12/2015
BUILDING FOUNDATIONS OR FACILITIES, IF ANY, ADJACENT TO PROJECT, INCLUDING FOOTINGS. REINF. DISTRIBUTION SOLID SLAB CEMENTITIOUS GROUT DRAWN BY: E.BOU HABIB 15/12/2015
TOP REINF. (EX: #12@200 TOP) BOTH WAYS 100mm THK. BLOCK WALL
# 12@200 TOP SEALING COMPOUND CHECKED BY:
50xBAR DIAMETER H.BOITARD / M.DRAIEF 15/12/2015

75
4- FORMWORK # 14@200 BOT. SAW CUT OR 50% CONTINUOUS APPROVED BY: J.M.LEPEUVEDIC 15/12/2015
25

PREMOLDED INSERT 50% SPLICED


BOTTOM REINF. (EX: #14@200 BOT.) 25mm THK. CEMENT SCREED PROTECTION LAYER
ELASTOMERIC WATER PROOFING SHEET 75mm THK. BLINDING CONCRETE
4-1 FORMS SHALL RESULT IN A FINAL STRUCTURE THAT CONFORMS TO FINAL GRADES, LINES AND DIMENSIONS OF
H

THE MEMBERS AS REQUIRED BY THE SHOP DRAWINGS AND SPECIFICATIONS.


EXCAVATION LEVEL
PILE
4-2 FORMS SHALL BE SUFFICIENTLY TIGHT TO PREVENT LEAKAGE OF MORTAR. MAX.SPACING OF CONSTRUCTION JOINTS: REINFORCED SHEET AT CORNER

Bahrain International Airport


10m FOR CASTING IN SUMMER
150

4-3 FORMS SHALL BE PROPERLY BRACED OR TIED TOGETHER TO MAINTAIN POSITION AND SHAPE. 15m FOR CASTING IN WINTER
WATERSTOP VAPOUR BARRIER
CASTED PORTION 50xBAR DIAMETER
4-4 FORMS AND THEIR SUPPORTS SHALL BE DESIGNED IN A WAY THAT DOES NOT DAMAGE PREVIOUSLY PLACED
STRUCTURE.
OF WALL TYPE REAR GUARD
TYPICAL 50% CONTINUOUS COMPACTED TO MINIMUM 95% TYPICAL PILE & PILE CAP CONNECTION AIRPORT MODERNIZATION PROGRAM
50% SPLICED STANDARD PROCTOR DENSITY
t/3 t/3 t/3

4-5 NO CONSTRUCTION LOADS SHALL BE SUPPORTED ON, NOR ANY SHORING REMOVED FROM ANY PART OF THE TYPICAL CONTRACTION JOINT
STRUCTURE UNDER CONSTRUCTION EXCEPT WHEN THAT PORTION OF THE STRUCTURE IN COMBINATION WITH THE 7- STEEL COLUMN CONNECTION TYPICAL DETAIL CLIENT: CLIENT REPRESENTATIVE :
t

REMAINING FORMING AND SHORING SYSTEM HAS SUFFICIENT STRENGTH TO SUPPORT SAFELY ITS WEIGHT AND
(MAXIMUM SPACING BETWEEN JOINTS = 10.00m)
LOADS PLACED THEREON. W STEEL COLUMNS

4-6 STRIPPING FORMS AND SHORES SHALL BE MINIMUM AS FOLLOWS: t/4


FOUNDATIONS............................8 HOURS PROTECTION WATERPROOFING ANCHOR BOLTS
COLUMNS AND WALLS..............18 HOURS NUTS
BOARD MEMBRANE
BEAMS (SIDES).........................18 HOURS WASHER
SLAB ON GRADE PROJECT MANAGER:
SLABS.......................................14 DAYS TYPICAL WALL CONSTRUCTION JOINT CONCRETE LEVEL STAKEHOLDER SIGN-OFF:
BEAMS & GIRDERS...................21 DAYS BASE PLATE

WATER STOP WITH NOTE: ALLOW 36 HOURS BEFORE


4-7 FORMWORK SHALL COMPLY WITH THE REQUIREMENTS OF "GUIDE TO FORMWORK OF CONCRETE" ACI 347 LATEST REPLACEMENT OF ADJACENT PANEL. BLOCK WORK WALL

50xBOLTS DIM
CRACK INDUCER
EDITION SLAB REINF.
HORIZONTAL BARS DESIGN CONSULTANT: STRUCTURE & MEP DESIGN
50∅ 50∅ IN WALL WITH SPACING (S)
4-8 FORMWORK SHALL BE IN ACCORDANCE WITH SPECIFICATIONS. CONSULTANT:
NON-SHRINK, NON-EXPANSIVE
4-9 ALL CONCRETE IN BASEMENTS TO HAVE SMOOTH FACES TO RECEIVE FINISHING. WALL REINF. CEMENT SAND GROUT
t

300 300
COLUMN NECK/PEDESTAL PHASE & DISCIPLINE:
5-BEAMS & GIRDERS NO CONCRETE JOINT SEALING HORIZONTAL BARS AT CONTROL JOINT PILE CAP TOP LEVEL
CONTINUITY & COMPOUND IN WALL WITH SPACING 2x(S) CONSTRUCTION PHASE
NO INITIAL GAP NUTS
STRUCTURAL
200

5-1 CAMBER ALL BEAMS AND GIRDERS AT LEAST 5mm PER METER SPAN GREATER THAN 5000mm UNLESS NOTED MAX. SPACING OF JOINTS:
7.5m APART FOR CASTING IN WINTER 1 WASHER PLATE
OTHER WISE. DRAWING TITLE:
5m APART FOR CASTING IN SUMMER 2 (60x60x10)TYPICAL
5-2 FOR TWO OR MORE LAYERS OF REINFORCING BARS, USE SEPARATORS SPACED AT 1000mm ON CENTER. A
SEE SLAB ON GRADE
BOTTOM REINF.
PASSENGER TERMINAL BUILDING
MINIMUM OF 2 SEPARATORS SHALL BE USED. FOUNDATION / PILE CAP

TYPICAL DETAIL OF CONTROL JOINT IN WALL


VAPOR BARRIER W+200
TYPICAL STEEL COLUMN-CONCRETE COLUMN NECK LEGEND & GENERAL NOTES
5-3 NO SPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS WHERE CRITICAL BENDING STRESS OCCURS. TENSION OVER THE COMPACTED FILL
COMPACTED TO MINIMUM 95% TYPICAL CONNECTION DETAIL
SPLICE IF REQUIRED SHALL BE 50 DIA FOR ALL BARS. LAP SPLICES SHALL BE WIRED TOGETHER. SPLICE TOP
BARS AT MID SPAN, BOTTOM BARS AT SUPPORT, NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION STANDARD PROCTOR DENSITY
SHALL BE PERMITTED TO BE SPLICED.
TYPICAL FOUNDATION OF BLOCK WALL
PROJECT NUMBER DRAWING NUMBER REV.
4351377
SCALE (A0) CP-B1000-S00-00030 A
NTS
KEY PLAN:

9- TYPICAL SOLID SLAB REINFORCEMENT DETAIL


1- STRENGTH,SIZES USED,SPLICE LENGTH 5- REINFORCEMENT COVER & SPACING 01 10 20 30 40 50 60 70 80 85
* MAX (1.5xL1, 0.33xL2)
MAX (0.33xL2, 0.33xL4) * * MAX (0.33xL3, 0.33xL4) 0.25xL4 *
HIGH TENSILE STEEL #8 #10 #12 #16 #20 #25 #32 A A1 A2 B1 B2 C1 C2 D1 D2 G1 G2 H1 H2
SOLID SLAB BEAM E'
C3 C4 D3 D4
- UNLESS OTHERWISE NOTED ON DRAWINGS, ALL REINFORCEMENT INCLUDING H

25mm
TIES AND STIRRUPS SHALL BE ∅ E1 E2 F1 F2
K'
40mm N
HIGH TENSILE STEEL (MIN. YIELD STRENGTH 420MPa)
0.1xL2 0.1xL3 0.1xL3 0.1xL4 0.1xL4 E3 E4 F3 F4
0.1xL2 T

vs
25mm
- UNLESS OTHERWISE NOTED, MINIMUM SPLICE LENGTH FOR HIGH TENSILE

40mm
STEEL TO BE AS FOLLOWS: V I1 I2 I3 I4
L1 L2 L3(SHORT SPAN) L4
SPACER BARS
HTS HIGH TENSILE STEEL :50 x BAR DIAMETER 1.5cg 1.5cg
#8 - 400mm
hs
#10 - 500mm
#12 - 600mm LEGEND:
_ MAX (
vs > ;(cg=25mm))
#16 - 800mm _ 70mm
hs >
#20 - 1000mm
#25 - 1250mm 10- TYPICAL BEAM REINFORCEMENT DETAIL
#32 - 1600mm

* 0.33xL1 0.33xMAX (L1 or L2) * 0.33xMAX (L1 or L2) MAX(0.33xL2 or L3) *


50xDIA 0.2xMAX (L1 or L2) 0.2xMAX (L1 or L2) B
TOP BARS AT MID SPAN TOP BARS AT MID SPAN 50xDIA 0.3xL2 TOP BARS
TOP BARS

2- SYMBOL 6-DETAILS OF SLAB SETDOWNS


SIDE BARS
BOTTOM BARS

D
1.50T
# DEFORMED BAR
@ SPACING CENTRE TO CENTRE
L LENGTH OF BARS (WHEN APPLICABLE) L1x0.1 L1x0.1 L2x0.1 L2x0.1
LIMIT OF AREA COVERED BY BARS

S
STIRRUPS AT SUPPORT STIRRUPS AT MID SPAN STIRRUPS AT SUPPORT STIRRUPS AT SUPPORT STIRRUPS AT MID SPAN STIRRUPS AT SUPPORT STIRRUPS STIRRUPS

T
ST STIRRUP BOTTOM BARS
BOTTOM BARS AT MID SPAN BOTTOM BARS AT MID SPAN

SECTION

S
- REINFORCEMENT SHOWN IN PLAN FOR ALL SLABS EXCEPT IN FOUNDATIONS: A L1 A L2 A L3

ADDITIONAL ADD.
S < 0.20 T
ALTERNATE ALT.
CONTINUOUS CONT.
REINFORCING REINF. 1.50T
REINFORCED CONCRETE RC.
LT LT
VERTICAL VER.
HORIZONTAL HOR.
BOTTOM BOT.

S
TOP TOP. T

11- DETAILS OF BEAM OPENING 12- TYPICAL COLUMN REINFORCEMENT DETAILS 13- WALLS TYPICAL REINF. DETAILS

S
LT LT
ALLOWABLE LOCATION A
CROSS-TIE
S < 0.80 T

D/3

MAX.
1.50T

350
6d
3- MINIMUM BENDING DIAMETER

D/3

D
LT M

B
IN
.

D/3
>3xDIAMETER
STANDARD HOOK & BEND OF LARGE ONE
T

CONFINED
HOOK EXTENSIONS BEND DIAMETER 0.3 Ln 0.4 Ln 0.3 Ln

REINF.
Ln
6d

D
S

DEG. SHAPE DEG. d U BARS SAME AS HORIZONTAL


4d BARS DIAMETER

JT. REINF.

50∅
50mm 2Sh
Sh :HOOP & SUPPLEMENTARY
d
d

180° 4d HOOP & STIRRUPS


D LT CROSS-TIES SPACING NOT EXEED
D

4d - 8db OF SMALLEST LONGITUDINAL BAR DIAMETERS


_
<90° 6d d<16
_ _ 0.80 T
S> - 24db OF HOOP BAR
d

135° 6d - A/2 (A SMALL COLUMN DIMENSION)


D d (a) ALLOWABLE LOCATION FOR OPENING

L0
Sh
6d d>16
_
d

- 300mm
6d
D

D(m) _
d

90° 12d _
D<0.40 0.40<D _
0.50<D _
0.60<D _
0.70<D _
0.80<D _
0.90<D _
1.00<D ST :COLUMN TIE SPACING NOT EXEED
D 8d d>29
_ ∅(m)
-16xdb OF VERTICAL BARS
12d

_
<0.05 REINFORCEMENT IS NOT NECESSARY

AS PER SCHEDULE
-48xdb OF TIES,

COLUMN TIES
_ -SMALLER DIMENSION OF COLUMN CROSS-SECTION 50∅
<0.10 TYPE 2 VERTICAL BARS
(db: DIAMETER OF BAR)
_
<0.15 TYPE 1
WALLS CORNER

ST
7- TYPICAL SLAB OPENING DETAIL _
<0.20
THERE MUST BE NO OPENING
L0 :MAX (LARGEST COLUMN DIMENSION),
_
<0.25 (1/6 CLEAR HEIGHT) 450mm.
TYPICAL REINF. DETAIL

SPLICE LENGTH
NOTE:
d1 ADDITIONAL 2#16 AT EACH
CORNER FOR OPENING > 3 (b) ADDITIONAL REINFORCEMENT AROUND OPENING ALL CONCRETE REINF. DETAIL SHOULD
r TIMES THICKNESS OF SLAB BE DONE IN ACCORDANCE WITH ACI -315

50mm Sh

L0
13

B = BEAM WIDTH DETAILING MANUAL .


COVER D = BEAM DEPTH


P = PITCH OF STIRRUP OF BEAM


w

JT. REINF.
COVER

ST-1 = LINK OF BEAM


1

2Sh
ST-2 = LINK OF BEAM @ 100
6
ST-3 = LINK OF BEAM @ 50

CONFINED
ADDITIONAL 1/2 OF NUMBER

REINF.
LENGTH d1 (in mm) FOR 135° HOOK OF BARS INTERRUPTED BY

D
OPENING PLUS ONE EACH SIDE
DIAMETER HORIZONTAL A
SUPPORT 10 12 14 16 20 25 32 SLAB AT 8mm U.N.O. D < 0.80 2- #12mm.
(mm) REINFORCEMENT
max(50x∅,A/2) B

WIDTH W (mm) OPENING D>_ 0.80 2- #16mm.


2 SETS
200 150 190 230 270 360 460 600

50∅
P < 0.15 BAR SIZE SHALL BE 2 SIZE LARGER THAN LINK TYPICAL COLUMN ELEV. SHOWING U BARS SAME AS HORIZONTAL
250 130 170 210 250 340 440 580 P >_ 0.15 BAR SIZE SHALL BE 1 SIZE LARGER THAN LINK BARS DIAMETER
300 110 150 190 230 320 420 560
INCLINE B
REINFORCEMENT
DOWELS AND TIES SPACING
4 SETS B<_ 0.35 2 BARS
350 90 13 170 210 300 400 550 B >_ 0.35 3 BARS REVISION:
400 70 110 150 190 280 380 530
max NOTE: FOR LARGE OPENINGS CHECK WITH THE STRUCTURAL ENGINEER
450 50 90 130 170 260 360 510
(50x∅,B/2) A
VERTICAL BARS
WALLS INTERSECTION
TYPICAL REINF. DETAIL

A 15/12/2015 ISSUED FOR CONSTRUCTION - MODIFICATIONS IF ANY ARE CLOUDED J.M.L


DATE
REV. (dd/mm/yy) DESCRIPTION OF REVISION APP.

8- WALLS OPENINGS TYPICAL REINF. DETAILS


NAME DATE (dd/mm/yyyy)
AT EACH CORNER AT EACH CORNER DESIGNED BY: A.KORJIEH 15/12/2015
ADDITIONAL 2#16 ADDITIONAL 2#16 ST-2 ST-3 ST-2 TOP OF COLUMN
ST-1 ST-1
DOOR OPENING DRAWN BY: E.BOU HABIB 15/12/2015
4- NON BEARING MASONRY WALLS 1.50 D
CHECKED BY: H.BOITARD / M.DRAIEF 15/12/2015

14- TYPICAL DETAIL FOR MECHANICAL CONCRETE PAD

COLUMNS TIES ARE AS PER SCHEDULE


APPROVED BY:
4-1 LINTELS ABOVE MASONRY OPENINGS: J.M.LEPEUVEDIC 15/12/2015

USE SAME HORIZONTAL USE SAME VERTICAL


OPENING
D

Length REINF. OF WALL REINF. OF WALL


(mm) 1500 2500 3500 5000
Width (mm) ∅ MECHANICAL REINF. CONCRETE PAD
THE EXACT DIMENSIONS AND REINF.
2T10 LT (TYP) TO BE PROVIDED BY THE CONTRACTOR

Bahrain International Airport


LT (TYP)
(CLEAR HEIGHT OF COLUMN)

AND TO BE SUBMITTED FOR


ADDITIONAL 2#16 ADDITIONAL 2#16 LT ∅ LT DESIGNER FOR APPROVAL
100 8@15
200

- - -
AT EACH CORNER AT EACH CORNER
100
(b.1) TYPE 1 REINFORCEMENT AIRPORT MODERNIZATION PROGRAM

H
4T10 4T10 2T10 2T10
H

ADDITIONAL 1/2 OF NUMBER


OF HORIZONTAL BARS INTERRUPTED CLIENT: CLIENT REPRESENTATIVE :
200

250

2T10
450

∅8@15 ∅8@15 ∅8@15 DOWELS 12@300


350

150 BY DOOR OPENINGS


∅8@15 FOR FOUNDATION OR SLAB IN BOTH DIRECTIONS
150 150 REINF REFER TO PLAN
150 2T14 150 2T16
LT (TYP)
L (BEAM SPAN)
SPLICE LENGTH

4T10 4T10 2T10 2T10


0.33xL REINF. CONCRETE FOUNDATION OR SLAB
200

250

2T10
450

∅8@15 ∅8@15 ∅8@15


350

200 ∅8@15 TOP BARS @ SUPPORT (CONT.)


D

200 PROJECT MANAGER: STAKEHOLDER SIGN-OFF:


200
200 2T14 200 2T16 ∅
ADDITIONAL 1/2 OF NUMBER ADDITIONAL 1/2 OF NUMBER
2T10 2T10 2T10 2T10
JT. REINF.
12d MIN.

OF VERTICAL BARS INTERRUPTED OF VERTICAL BARS INTERRUPTED LT (TYP)


2T10
BY DOOR OPENING BY DOOR OPENING 2-T12 (TYP)
TYPICAL DETAIL FOR MECHANICAL CONCRETE DESIGN CONSULTANT:
200

250

STRUCTURE & MEP DESIGN


450

∅8@15 ∅8@15 ∅8@15


350

250
CONSULTANT:
(b.2) TYPE 2 REINFORCEMENT PAD OVER THE FOUNDATION OR FLOOR SLAB
∅8@15
2T12 2T12 2T14
250 250
CONF. REINF. TIES

250 250 2T16


DOOR OPENING
LAT. TIES

0.10L BOTTOM BARS


-LINTELS SHALL BEAR ON MASONRY 40cm ON EACH SIDE OF OPENING. AT MID SPAN
PHASE & DISCIPLINE:
EXTRA TOP BARS
4-2 MASONRY WALL BRACING:
@ SUPPORT
CONSTRUCTION PHASE
40cm WIDTH WALL THICKNESS EVERY 300cm.
STRUCTURAL
MASONRY WALLS SHALL BE LATERALLY SUPPORTED IN EITHER HORIZONTAL DRAWING TITLE:
OR THE VERTICAL DIRECTION AT INTERVALS NOT EXCEEDING THE FOLLOWING:
1- WALL HEIGHT > 500cm PROVIDE CONTINUOUS LINTEL AT MID HEIGHT.
PASSENGER TERMINAL BUILDING
2- WALL HEIGHT > 400cm AND LENGTH > 500cm PROVIDE VERTICAL POST ELEMENT
LEGEND & GENERAL NOTES

PROJECT NUMBER DRAWING NUMBER REV.


4351377
SCALE (A0) CP-B1000-S00-00040 A
NTS
KEY PLAN:
09- STRANDS AND WIRES
01- HOLLOW CORE DESIGN
PROTRUDING STRANDS AND WIRES: IT IS FORBIDDEN TO CUT ANY OF THEM. c- SMALL OPENINGS: CORE HOLES ARE THE MOST COMMON TYPE OF PENETRATION HOLES THAT
ARE SMALLER THAN 50mm DIAMETER CAN BE EASILY ACHIEVED BY SIMPLY
17-STANDARD CUT SLABS
HOLLOW CORE SLABS SHALL BE ANALYZED & DESIGNED AS SIMPLY DRILLING THE HOLE ON SITE TO SUIT THE BUILDING REQUIREMENTS IS
SUPPORTED FLEXURAL MEMBERS PINNED AT END SUPPORTS IN ACCORDANCE 10- OPENINGS RECOMMENDED TO LOCATE THESE HOLES ON THE CORES OF THE HOLLOW CORE SLABS CAN BE PRODUCED WITH PARTIAL WIDTH. THESE NARROW
WITH ACI 318-11. HOLLOW CORE SLABS ARE DESIGNED TO HAVE EFFECTIVE HOLLOW CORE TO AVOID CUTTING THE STRANDS .PREFERABLY , HOLES SHOULD SLABS ARE PRODUCED BY CUTTING THE STANDARD WIDTH SLABS AFTER THE 01 10 20 30 40 50 60 70 80 85
SHEAR KEY JOINTS BETWEEN ADJACENT SLABS SUCH THAT WHEN GROUTED IT IS STRICTLY FORBIDDEN TO PUNCH OR UNDERTAKE NON FORESEEN OPENINGS ON THE
BE ALIGNED ON THE SLAB SO THAT THE FEWEST NUMBER OF STRANDS IS CUT EXTRUSION. PARTIAL WIDTH SLABS, IT IS ADVISED THAT THE CUT EDGE IS PLACED
THE INDIVIDUAL SLABS BECOME A SYSTEM THAT BEHAVES SIMILARLY TO A LAYOUT DRAWINGS.
AS POSSIBLE. NEW LINE IT IS IMPORTANT THAT PRE STRESSING STRANDS ARE NOT EXPOSED OVER THE SUPPORTING WALL OR BEAM, AS THE CUT EDGE WILL BE STRAIGHT
MONOLITHIC SLAB. EXPOSED THROUGH THE CONCRETE. NO DRILLING SHALL BE MADE ON THE WITHOUT CHAMFER AS FOR FULL WIDTH SLABS. TO ENSURE THE STRUCTURAL A1 A2 B1 B2 C1 C2 D1 D2 G1 G2 H1 H2
A
02- CONCRETE CARACTERISIC 11- HOLLOW CORE INSTALLATION SHADED AREA. (SEE FIGURES BELOW) ADEQUACY OF THE SLAB, THERE ARE RESTRICTIONS ON THE WIDTH OF SLABS
C3 C4 D3 D4
E'
THAT ARE AVAILABLE AS SHOWN ON THE TABLE BELOW. H
ALL INSITU CAST CONCRETE SHALL HAVE A CARACTERISIC CYLINDER STRENGTH 1- MEAN OF HANDLING K'
N E1 E2 F1 F2
AT 28 DAYS f'c =40 MPA. 1a- USE A SPREADING BEAM OR A FABRIC FLAT CABLE WITH THE ADEQUATE CAPACITE
FOR PRESTRESSED CONCRETE COMPONENTS IT IS 40 MPA. 1b- LIFTING POINT NOT TO EXCEED 50cm FROM THE EDGE OF THE HOLLOW CORE SLAB T E3 E4 F3 F4
1c- FOR A FLAT CABLE IS USED, CHECK VISUALLY ON DAILY BASIS THE CABLE. IF DAMAGED,
03- PASSIVE REINFORCING CHANGE IT AT ONCE. MINIMUM WIDTH OF NARROW SLABS V I1 I2 I3 I4
PASSIVE REINFORCING BARS SHALL HAVE A YIELD STRENGTH OF 420 MPA. 2- HANDLING CRANE
2a- CHECK ITS CAPACITY IN RELATION WITH THE SLAB MAXIMUM WEIGHT AND ITS DISTANCE
04- OVERLAPPING FROM THE CRANE BODY. SLAB THICKNESS MINIMUM WIDTH
OVERLAPPING LENGTH FOR ALL REINFORCEMENT BARS SHALL HAVE A ADD TO THE ABOVE MENTIONED WEIGHT THE WEIGHT OF THE SPREADING BEAM IF THIS
MINIMUM OF 50xD. (mm) (mm)
DEVICE ISUSED. LEGEND:
D BEING THE DIAMETER OF THE LARGER BAR. 2b- CHECK THE EFFECTIVE CAPACITY OF THE CRANE: LIFT A LARGER WEIGHT SLAB (AT LEAST 150 330
10% LARGER) AT THE REQUIRED DISTANCE, AT FEW cm ONLY FROM THE GROUND AT THE 200 430
05- BEARING SUPPORTS PRESENCE OF THE CRANE RESPONSIBLE (IF THE CRANE IS HIRED, HAVE THE CRANE
HOLLOW CORE SLABS CAN BE SUPPORTED ON MANY TYPES OF SUPPORTS 265 530
TECHNICIAN OF THE HIRING COMPANY PRESENT FOR THIS TEST.)
DESIGNED TO CARRY THE DEAD AND LIVE LOADS REQUIRED. PRE CAST ISSUE A REPORT TO BE SIGNED BY ALL THE ATTENDANTS. 320 690
BEAMS , PRE CAST WALLS , CAST-IN-SITU CONCRETE BEAMS & WALLS, & 3- DIFFERENCE IN COUNTER DEFLECTION. HOW TO LEVEL THE HOLLOW CORE SLABS AT THE
STRUCTURAL STEEL BEAMS ARE ALL SUITABLE FOR USE WITH HOLLOW CORE 400 690
SLABS AS LOAD BEARING SYSTEMS.
SAME COUNTER DEFLECTION.
3a- IT IS A MATTER OF FACT THAT THERE IS ALWAYS DIFFERENCES IN COUNTER DEFLECTION.
16-1 HCS 150 SMALL HOLES LOCATION 500 690
THE MINIMUM END BEARING OF SIMPLY SUPPORTED HOLLOW CORE SLABS THIS DIFFERENCE IS ACCENTUATED WITH THE AGE OF HE PRODUCED SLABS.
SHOULD NOT BE LESS THEN 60mm. BUT UNDER NORMAL CONDITION, IT IS 1154
3b- IN ORDER TO LEVEL THE HOLLOW CORE SLABS AT THE SAME COUNTER DEFLECTION: USE
ALWAYS DESIGNED AS 80mm WITH CONSIDERATION FOR TOLERANCES ON THE A FILLETED ROD OR BETTER A DIWIDAG ROD WITH TWO WASHERS AND SCREWS BETWEEN 80 142 142 142 142 142 142 142 80

20
MAIN LOAD BEARING STRUCTURE. THE TABLE BELOW SHOWS THE NOMINAL THE SLABS. THIS IS USUALLY ENOUGH TO GET THE CONTIGUOUS SLABS TO THE SAME LEVEL.
BEARING LENGTH REQUIREMENTS FOR EACH SLAB THICKNESS.
THE HIGHER THE RATIO OF LENGTH/DEPTH IS, THE EASIER THIS OPERATION IS. 110
18-STRUCTURAL TOPPING

110
150
3c- PLACE THE TOP STEEL ON THE SLAB AS PER DRAWINGS. POUR CONCRETE IN THE SHEAR KEY
HOLLOW CORE BEARING LENGTH BETWEEN TWO SLABS AT ABOUT THE MID SLAB OVER A LENGTH OF 50 TO 100cm. HOLLOW CORE SLAB'S STRUCTURAL CAPACITY CAN BE ENHANCED BY THE INTRODUCTION OF STRUCTURAL TOPPING.

20
LET THE CONCRETE HARDEN FOR A COUPLE OF DAYS, THAN RELEASE THE SCREWS. TAKE OFF 28.21 THE MINIMUM THICKNESS REQIURED IS 75mm WITH CONCRETE CYLINDER STRENGTH OF 28 th DAY OF AT LEAST 40MPa.
SLAB THICKNESS BEARING LENGTH 1196 IT IS FURTHER RECOMMENDED THAT WIRE MESH BE USED TO REINFORCE THE STRUCTURAL TOPPING.
THE RODS AND POUR CONCRETE ON ALL THE AREAS.
(mm) (mm) WITH PROPER CONNECTION BETWEEN HOLLOW CORE SLAB AND TOPPING. THE TWO WILL ACT AS A COMPOSITE SECTION.
22.6 40 89.4 40 102 40 102 40 102 40 102 40 102 40 102 40 89.4 40 22.6
THIS INCREASES THE LOAD BEARING CAPACITY OF THE SLAB AND IS ESPECIALLY SUITABLE WITH GREATER IMPOSED LOADS.
150 60 TO 80
TYPICAL CONNECTION DETAILS ARE SHOWN BELOW.
200 80 (NOMINAL)
265 80 (NOMINAL) COUNTER-DEFLECTION
320 120 (NOMINAL)
400 150 (NOMINAL)
500 150 (NOMINAL)
16-2 HCS 200
1145 A
06- DIMENSIONS & TOLERANCES :
92 187 187 187 187 187 92
HOLLOW CORE SLABS SHALL BE SUPPLIED IN ACCORDANCE WITH THE FOLLOWING TOLERANCES.
B

24

35
39
12-ERECTION 152

152

200
DIMENSIONS TOLERANCES
THE HOLLOW CORE SLABS SHALL BE INSTALLED BY THE MANUFACTURER OR A
(mm) (mm)
COMPETENT ERECTION CONTRACTOR. WHERE THE MANUFACTURER ALSO

35

35
UP TO 4.50m ± 9 mm ERECTS THE HOLLOW CORE SLABS, THE BUILDING CONTRACTOR SHALL BE
RESPONSIBLE FOR PROVIDING SUITABLE ACCESS AT THE SITE TO ENABLE TRUCKS
LENGTH
4.50 to 6.00m ± 12 mm
AND CRANES TO OPERATE UNDER THEIR OWN POWER. THE BUILDING CONTRACTOR
54 154 33 154 33 154 33 154 33 154 33 153.9 54
A B
6.00 to 12.00m ± 18 mm SHALL ALSO BE RESPONSIBLE FOR PROVIDING TRUE & LEVEL BEARING SURFACES
12.00 to 20.00m ± 24 mm
FOR THE SUPPORT OF THE HOLLOW CORE SLABS. 1197
TEMPORARY SHORING & BRACING, IF NECESSARY, SHALL COMPLY WITH
0 mm THE MANUFACTURER RECOMMENDATIONS. BEARING STRIPS SHALL BE ACCURATLY
WIDTH 1200mm
-3 mm SET WHERE REQUIRED. ANY REINFORCEMENT REQUIRED SHALL BE PLACED AS TYPICAL REINFORCEMENT DETAIL OF STRUCTURAL TOPPING
DETAILED ON THE DRAWINGS. KEYWAYS SHALL BE FILLED & COMPACTED WITH
WIDTH OF PART +20 mm A 3:1 SAND-CEMENT GROUT MIX OR BY THE TOPPING CONCRETE USING A
SLAB -20 mm TO PREVENT PENETRATION OF TOPPING INTO THE CORES BY MORE THEN 50mm.
END FILLING SHOULD NOT BE MORE THEN THE SUPPORT LENGTH UNLESS
+3 mm DETAILED BY THE DESIGNER. 16-3 HCS 265
THICKNESS
-3 mm 1154
B A
SQUARNESS OF +6 mm Small holes location
SLAB -6 mm
13-ATTACHMENT & PENETRATION 131 223 223 223 223 131
#8 @ 200 #8-UPDTICK BAR @ 500 #8 @ 200 #8-UPDTICK BAR @ 500
ATTACHEMENTS & FIXINGS TO THE HOLLOW CORE SLABS SHALL BE IN ACCORDANCE STRUCTURAL SCREED MIN. 60mm IN ALL JOINTS STRUCTURAL SCREED MIN. 60mm IN ALL JOINTS

35
BOW/WIND 10 mm PER 3000 mm WITH THE APPROVED DETAILS ONLY & SHALL NOT IMPAIR OR REDUCE THE f'c=40MPa f'c=40MPa
STRENGTH OF THE FLOOR SLABS. HOLLOW CORE SLABS MAY BE DRILLED
PROVIDED NO CONTACT IS MADE WITH THE PRESTRESSING STRANDS SUBJECT
LOCATION OF +20 mm
TO APPROVAL OF THE STRUCTURAL ENGINEER. SEVERAL TYPES OF ANCHORS,

265

195
INSERTS BOLTS & SCREWS CAN BE USED TO ACHIEVE THIS PURPOSE. SHOULD SPALLING 180
-20 mm
OCCUR, IT SHALL BE REPAIRED BY THE TRADE DOING THE DRILLING.
+3 mm
COVER TO STRAND

35
-3 mm 14-DEFLECTIONS
2 mm/m BUT NOT 1196

HCS

HCS
TOTAL DEFLECTION IS DEFINED AS THE UPWARD CAMBER OF THE SLAB DUE TO
DIFFERENTIAL CAMBER OF ADJACENT UNITS
GREATER THAN 15mm THE ECCENTRICITY OF THE PRE TENSIONING LESS THE DOWNWARD DEFLECTION 75 144 89 134 89 134 89 134 89 144 75
DUE TO APPLIED LOADS, INCLUDING THE LONG TERM EFFECTS OF PRE STRESS
LOSS, CREEP & SHRINKAGE. DEFLECTIONS ARE ALSO AFFECTED BY THE AMOUNT
OF PRE STRESSING ONLY BECAUSE PRE STRESSING ESTABLISHES THE LOAD AT
07- HANDLING AND TRANSPORT: WHICH A MEMBER WILL CRACK. #8 TOP BAR #8 TOP BAR
FOR PRESTRESSED BEAM: ALLOWABLE LOADS FROM THE SPAN-LOAD TABLES LIMIT THE THEORETICAL TOTAL
HOLLOW CORE SLAB HOLLOW CORE SLAB
USE IDENTICAL LIFTING CABLES WITH MINIMUM LENGTH EQUAL TO "1.5 L" DEFLECTION TO L/350 OR 20mm WHICHEVER IS LESSER . IN ADDITION, THE #8 BOTTOM BAR #8 BOTTOM BAR
L=MAX DISTANCE BETWEEN TWO LIFTING ANCHORS. DEFLECTION DUE TO PRE STRESS & DEAD LOAD, INCLUDING LONG-TERM EFFECTS,
IS LIMITED TO L/240. INSTANTANEOUS DEFLECTIONS DUE TO LIVE LOADS ARE
SECTION A SECTION B
MI

LIMITED TO L/360.
N1

CAMBER IS THE UPWARD DEFLECTION OF A PRE STRESSED MEMBER & RESULTS 16-4 HCS 320
.5x

FROM THE PRE STRESSING FORCE BEING ECCENTRIC FROM THE CENTER OF
L

GRAVITY OF THE GROSS SECTION. PRE STRESSED HOLLOW CORE SLABS WILL 1154
EXHIBIT AN UPWARD CAMBER , THE DEGREE OF WHICH WILL DEPEND UPON THE
SPAN & AMOUNT OF PRE STRESSING FORCE APPLIED. DUE ALLOWANCE MUST BE 153 283 283 283 153
MADE FOR THIS IN DETERMINING FINISHES & OVERALL FLOOR THICKNESS. Small holes location
21
FOR HOLLOW CORE SLAB:
a- Clamps and spreading beam
PRESTRESSED BEAM 15- POINT LOADS 19-SLAB JOINT

52
L POINT LOADS SHALL NOT EXCEED 30KN & SHALL BE DISTRIBUTED OVER AN THE LONGITUDINAL KEYS BETWEEN ADJACENT SLABS MUST BE FILLED
AREA OF MINIMUM 150X150. WITH GROUT TO FULLY DEVELOP THE CONCENTRATED LOAD DISTRIBUTION

195
16-H.C. TYPICAL PENETRATION DETAILS & SHEAR FRICTION CAPACITY OF THE SLAB SYSTEM.
ß à ß à 64 226 54 229 54 229 54 226 64

320
LARGE OPENINGS & CUTOUTS FOR MECHANICAL, ELECTRICAL & PLUMBING
ARE SIGNIFICANTLY FLEXIBLE IN HOLLOW CORE SLAB FLOOR SYSTEM.
MAX 50cm MAX 50cm HOLLOW CORE SLAB JOINT GROUT
THERE ARE SEVERAL DIFFERENT WAYS THAT THESE CAN BE ACCOMPLISHED. REVISION:
EXAMPLES OF THESE ARE SHOWN ON FIGURE BELOW & CAN BE DESCRIBED
AS FOLLOWS INTENDED OPENINGS SHOULD BE PLACED IN THE SHOP

52
DRAWINGS DURING THE APPROVAL PROCESS SO THAT THEY CAN BE PROPERLY
DESIGN ENGINEERED.
91 153 150 129 150 129 150 153 91

HCS

HCS
x y y x a- LARGE OPENINGS: BIGGER CUTOUTS SUCH AS FOR MECHANICAL SERVICES,
CAN BE EASILY CATERED AS SHOWN ON FIGURE BELOW. THESE LARGER CUTOUTS 1196
OF UP TO 400mm ARE NOMINATED DURING THE DESIGN PROCESS TO ALLOW
THE DESIGN TO TAKE INTO ACCOUNT THE LOCAL STRAND AND WEB REDUCTION.
THESE CUTOUTS ARE GENERALLY PRE-CUT IN THE FACTORY PRIOR TO INSTALLATION.
SLAB JOINT (SHEAR KEY)

A 15/12/2015 ISSUED FOR CONSTRUCTION - MODIFICATIONS IF ANY ARE CLOUDED J.M.L


DATE
Å

16-5 HCS 400 20- HOLLOWCORE ON BEAM TYPICAL SECTION REV. (dd/mm/yy) DESCRIPTION OF REVISION APP.

OPENINGS & CUTOUTS ORIENTATION


69 215 76 215 76 215 76 215 69 #8 @ 200 #8 @ 200
25.759.81 STRUCTURAL SCREED STRUCTURAL SCREED NAME DATE (dd/mm/yyyy)
f'c=40MPa f'c=40MPa DESIGNED BY:
38

A.KORJIEH 15/12/2015
152
152

50

36 DRAWN BY: E.BOU HABIB 15/12/2015


50

36

CHECKED BY: H.BOITARD / M.DRAIEF 15/12/2015

HCS

HCS
APPROVED BY: J.M.LEPEUVEDIC 15/12/2015
b < 400 215 76 215 76 215 76 215 HOLLOWCORE SLAB HOLLOWCORE SLAB
400

300

cm
50 1200
312

X
45°

MA

X
60
X
SEALANT FILL
60

X
CONCRETE CAST-IN-SITU BEAM

Bahrain International Airport


50

152
22
152

b- Flat cable handling CONTINUOUS


Safety cable to be released only when slab X: DIMENSIONS REFER KOROLATH SHIMMER
X 3mm THICK
AIRPORT MODERNIZATION PROGRAM
35

reaches it support TO BEAM DETAILS


122.6 180.89 171.69 186.41 171.69 186.41 171.69 180.89 122.6
b < 400 1196
cm
X 50 1200 CLIENT: CLIENT REPRESENTATIVE :
MA

21- HOLLOWCORE ON BEAM TYPICAL CONNECTION DETAIL


8- STORAGE b- STEEL HANGERS: LARGE OPENINGS CAN BE CATERED FOR BY THE USE OF STEEL HANGERS.
WHEN THESE LARGE PENETRATIONS ARE REQUIRED. STEEL HANGERS ARE USED
A- THE PRESTRESSED COMPONENTS MUST BE STORED ON THEIR TO TRANSFER THE LOAD TO THE ADJACENT SLABS. THESE SLABS ARE DESIGNED TO PROJECT MANAGER: STAKEHOLDER SIGN-OFF:
BASE ON HORIZONTAL SUPPORT. SUPPORT THE ADDITIONAL LOAD WITHOUT THE NEED FOR SUPPORTING COLUMNS. 16-6 HCS 500
B- THE TIMBERS MUST BE ALIGNED ON THE SAME VERTICAL.
69 197 76 197 76 197 76 197 69 ST#10@200
• PRESTRESSED BEAM: ONLY 21 8 DESIGN CONSULTANT: STRUCTURE & MEP DESIGN
LAYER ONE ONE
CONSULTANT:
38

50

PRESTRESSED BEAM 36
50

36

SUPPORT
STEEL HANGER
Max 500mm
215 76 215 76 215 76 215 PHASE & DISCIPLINE:
Compacted and plan storage area max.300 max.300
4#16
CONSTRUCTION PHASE
500

400

STRUCTURAL
412

PRESTRESSED RIBBED SLAB (PRS) & HOLLOW CORE SLAB (HCS)


DRAWING TITLE:
60
CORRECT WRONG
PASSENGER TERMINAL BUILDING
60

WALL
Max. 6 Layer

LEGEND & GENERAL NOTES


50
22

TIMBER
HOLLOW CORE
120 110 171.69 110 171.69 110 171.69 110 120
SUPPORT SUPPORT 1196
PROJECT NUMBER DRAWING NUMBER REV.
Max 500mm 4351377
SCALE (A0) CP-B1000-S00-00050 A
NTS
KEY PLAN:

A- GENERAL. FIRE RESISTANCE TABLE


1- THE NOTES SHALL BE READ IN CONJUNCTION WITH THE SPECIFICATIONS. COMPONENT FIRE RESISTANCE 01 10 20 30 40 50 60 70 80 85

(hr)
2- DO NOT SCALE FROM DRAWINGS, ALL DIMENSIONS SHOULD BE READ OR COMPUTED. A
- A A1 A2 B1 B2 C1 C2 D1 D2 G1 G2 H1 H2
1- COLUMNS FOR ALL FLOOR EXCEPT E'
3- UNLESS OTHERWISE NOTED ON THE DRAWINGS, DIMENSIONS ARE GIVEN IN MILLIMETERS AND LEVELS IN METERS. C3 C4 D3 D4
(2hr) H
COLUMNS SUPPORT ROOF ONLY. CL OF SLEEVE OPENING CL OF BEAM K'
N E1 E2 F1 F2
4- ALL STEEL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH ALL RELATED DRAWINGS.

MAX. SLEEVE =180


T E3 E4 F3 F4

CL OF BEAM & OPENING


2- COLUMNS SUPPORT ROOF ONLY. (1hr)
5- ALL LEVELS AND DIMENSIONS ARE TO BE VERIFIED BY SITE MEASUREMENTS PRIOR TO EXECUTION. I1 I2 I3 I4

MIN.
V

D/4
12 THICK P L

6- STRUCTURAL MEMBERS AND CONNECTIONS SHOWN ARE INDICATIVE ONLY. 3- BEAMS FOR ALL FLOORS EXCEPT 100 100
(2hr)
THE CONTRACTOR SHALL FULLY DESIGN ALL STRUCTURAL MEMBERS AND
BEAMS SUPPORT THE ROOF.

D
LEGEND:
CONNECTIONS AND SUBMIT THE STRUCTURAL CALCULATIONS AND SHOP (TYP.)

DRAWINGS FOR THE CONSULTANT'S APPROVAL.


4- BEAMS SUPPORT ROOF ONLY. (1hr)

MIN.
MAX. SLEEVE =180

D/4
7- FACADE STEEL TUBES TO BE RECHECKED BY THE FACADE CONTRACTOR.

B- LOADS. E- FABRICATION/ERECTION
1- DEAD LOADS (DETAILS IN THE CALCULATION SHEETS). 1- ALL DIMENSIONS GIVEN ON CONTRACT DRAWINGS ARE TO 11-TYPICAL DETAIL OF BEAM
SECTION "A"
BE CHECKED BY THE STEEL FABRICATOR PRIOR TO FABRICATION. SLEEVE FOR PLUMBING
2- LIVE LOADS ARE IN ACCORDANCE WITH IBC 2009,
ROOF LIVE LOADS FOR INACCESSIBLE ROOF: 2- THE CONTRACTOR SHALL PROVIDE ALL HOLES IN THE STEELWORK
FOR ROOF AREA<100m² = 1.2KN/m² & MAX OF 120KN REQUIRED BY OTHER TRADES SUBJECT TO THE APPROVAL OF THE ENGINEER
FOR ROOF AREA>100m² = 0.58KN/m² B
3- THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING AND SUPPORTS
A COMPLEMENTARY LIVE LOAD OF 0.5KN/m² SHALL BE ADDED FOR POSSIBLE SAND ACCUMULATION -

REQUIRED DURING ERECTION FOR THE PROPER ALIGNEMENT AND ALSO 25 THICK P S L
AS NECESSARY TO GIVE AND MAINTAIN PROPER STABILITY OF ALL STRUCTURES. TYP.
CL OF BEAM OPENING
3- SEISMIC LOADS ARE IN ACCORDANCE WITH IBC 2009, TAKING S1=0.037, Ss=0.092
4- THE THREADING OF THE PRESET ANCHOR BOLTS IS TO BE TESTED
4- WIND LOADS ARE IN ACCORDANCE WITH ASCE 7-10 WITH WIND SPEED 45m/sec, EXPOSURE D
TO GUARANTEE THAT NO SLIP OF NUTS OCCURS BEFORE

CL OF BEAM & OPENING


D/4 (MIN.)

10
THE ANCHOR BOLTS MATERIAL FAILURE.

D/2
C- DESIGN 5- FABRICATION, ERECTION AND QUALITY CONTROL (INCLUDING TOLERENCES) 10
R 50

TO BE AS INDICTATED BY ASTM A6, AWS D1.1 AND AISC - ASD (MANUAL

H
D
H/2+80 W H/2+80
-THE DESIGN IS IN ACCORDANCE WITH THE FOLLOWING STANDARDS OF STEEL CONSTRUCTION).

D
H
1- MANUAL OF STEEL CONSTRUCTION-AMERICAN INSTITUTE OF STEEL CONSTRUCTION 14TH EDITION AISC-360-2010 6- ALL HOLES FOR STEEL BOLTS SHALL BE MAXIMUM 1.5 mm LARGER THAN
THE NOMINAL DIAMETER OF THE BOLT, UNLESS OTHERWISE NOTED. D/4 (MIN.)

2- AMERICAN INSTITUTE OF STEEL CONSTRACTION ANSI/AISC 360-10, 2010

10
7- TORQUE TIGHTENING OF ALL HEAD PLATES CONNECTIONS AND
3- COLD FORMED STEEL DESIGN MANUAL-AMERICAN IRON AND STEEL INSTITUTE (AISCI) 2010 EDITION. BOLTED SPLICES ARE SLIP CRITICAL CONNECTIONS THAT REQUIRES FULL
PRE TENSIONING AS PER THE REQUIREMENTS OF RCSC SPECIFICATIONS
4- STRUCTURAL WELDING CODE: AMERICAN WELDING SOCIETY AWS D1.1 /D1.1M : 2010 FOR STRUCTURAL JOINTS. TYPICAL ALL TOP, BOTT.
TYPICAL
AND SIDE P S. L

5- STEEL STRUCTURE PAINTING MANUAL: STEEL STRUCTURES PAINTING COUNCIL-LATEST EDITION . 8- PAINTING OF ALL FAYING SURFACES FOR HEAD PLATE CONNECTIONS
AND SPLICE PLATES ARE TO BE CONSIDERED AS PER THE REQUIREMENTS NOTE :"D" DENOTES DEPTH OF BEAM SECTION "B"
OF SURFACE CONDITIONS OF SLIP CRITICAL CONNECTIONS CLASS "B" AS SPECIFIED 12-BEA M OPENING DETAIL
D- MATERIAL IN RCSC SPECIFICATIONS FOR STRUCTURAL JOINTS.

9- MINIMUM SIZE OF FILLET WELDS TO BE S=6mm. UNLESS OTHERWISE NOTED


1- STRUCTURAL STEEL PLATES AND HOT ROLLED SECTIONS ARE TO CONFORM TO:
FOR (BUILT UP SECTIONS FILLET WELD SIZE EQUAL 0.7 MINIMUM THICKNESS. (U.N.O).
ASTM A572 GRADE 50 MINIMUM YIELD STRENGTH 345 N/mm2.
10- NON-SHRINK GROUT TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF
2- STRUCTURAL STEEL PIPES ARE TO CONFORM TO :
40MPa AT 28 DAYS HAVING A WORKING TIME OF 2 HOURS.
ASTM A913 HAVING A MINIMUM YIELD STRENGTH OF 460 N/mm2 OR EQUAL.
11- CONTRACTOR IS TO SUBMIT WORKSHOP DETAIL DRAWINGS FOR THE
3- STRUCTURAL STEEL SQUARE AND RECTANGULAR TUBES ARE TO CONFORM TO :
ENGINEER'S APPROVAL PRIOR TO EXECUTION.
ASTM A500 GRADE "C" HAVING A MINIMUM YIELD STRESS OF 345 N/mm2 OR EQUAL.
12- REHEAT AND COOLING TREATMENT:
4- COLD FORMED STEEL Z AND C SECTIONS TO BE ASTM A500 GRADE C COMPARATIVE TABLE BETWEEN STEEL GRADES
THE PREHEAT AND INTERPASS TEMPERATURE MUST BE SUFFICIENT
HAVING A MINIMUM YIELD STRESS 345 N/mm2 TO PREVENT CRACKING. FLANGES, AT LOCATION OF WEB WELD, EUROPEAN AISC
OR EQUAL AND SHALL BE GALVANIZED IN ACCORDANCE WITH THE ASTM A653 M WITH ZINC SHALL BE PREHEATED TO A TOTAL WIDTH OF 200mm. MAINTAIN S 235 A 36
COATED TO ACHIEVE THE SPECIFIED LIFE TO THE FIRST MAINTENANCE. SPECIFIED TEMPERATURE DURING WELDING. AVOID OVERHEATING. S 275 A 572 GR 42

COOLING RATE SHOULD BE SLOW TO AVOID CRACKING, AND TO S 355 A 572 GR 50


5- CHEQUERED PLATES ARE TO CONFIRM TO ASTM A36 WITH MINIMUM YIELD STRENGTH OF 245 N/mm2 OR EQUAL ENSURE WELDED JOINT DUCTILITY. THE CONTRACTOR SHALL SUBMIT A
METHOD STATEMENT ON PREHEATING/COOLING PROCEDURES AND
6- ANCHOR BOLTS :
TECHNIQUES BASED ON AWS D1.1 REGULATIONS FOR THE ENGINEER'S
ARE TO CONFORM TO ASTM F1554 GRADE 55 WITH MINIMUM YIELD STRENGTH 380 N/mm2 WITH APPROVAL PRIOR TO FABRICATION.
ASSOCIATED TWO NUTS AND WASHER, TYPICALLY USED.
13- COMPOSITE STEEL / CONCRETE FLOORING IS NOT TO BE SUBJECTED TO CUTS/OPENINGS
7- HIGH-STRENGTH BOLTS, NUTS, AND WASHERS: ASTM A 490M, TYPE 1,
OTHER THAN THOSE SHOWN ON DRAWINGS PRIOR TO OBTAINING THE ENGINEER'S APPROVAL .
HEAVY HEX STEEL STRUCTURAL BOLTS,
HEAVY HEX CARBON-STEEL NUTS, AND HARDENED CARBON-STEEL
14- ALL STEEL MEMBERS NOT SUBJECTED TO FIRE PROTECTION ARE TO RECEIVE CORROSION
WASHERS, UNCOATED.
PROTECTION IN ACCORDANCE WITH PROJECT SPECIFICATIONS.
8- SHEAR CONNECTORS ARE TO CONFIRM TO ASTM A108, WITH MINIMUM YIELD STRENGTH
15- ALL STEEL ELEMENTS ARE SUPJECTED TO FIRE PROTECTION, THE RECOMMENDED
OF 345N/mm2, WITH MECHANICAL PROPERTIES TO ASTM A370, WITH RECOMMENDED PRACTICE
ENDURANCE TIME AS SHOWN IN THE TABLE AND FIRE PROTECTION MATERIALS ACCORDING TO THE ARCH. REQUIREMENTS
FOR STUDS WELDING TO AWS D1.1, TYPE B
REVISION:
16- THE REQUIRED MECHANICAL OPENINGS IN THE STEEL BEAMS IN THE WEBS OF THE BEAMS , THE CONTRACTOR CAN FOLLOW
9- WELDING MATERIALS: CONFORM TO AWS CODE AND AWS FILLER
THE BELOW SKETCHES AND IMPLEMENT THE REQUIRED STIFFENINGS AROUND THE MECHANICAL OPENINGS
METAL SPECIFICATIONS. SELECT MATERIALS WHICH ARE SUITABLE
FOR USE WITH TYPES OF STEEL TO BE JOINED. UNLESS OTHERWISE
INDICATED, CONNECTIONS ARE DESIGNED FOR:
- METAL-ARC WELDING ELECTRODES: TO E70XX SERIES OF THE
SPECIFICATION FOR MILD STEEL COVERED ARC-WELDING.
ELECTRODES, AWS A5.1, OR THE SPECIFICATION FOR LOW-ALLOY
STEEL COVERED ARC-WELDING ELECTRODES, AWS A5.5.
- BARE ELECTRODES AND GRANULAR FLUX USED IN THE
SUBMERGED-ARC PROCESS ARE TO CONFORM TO THE OF AISC "SPECIFICATION
FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL A 15/12/2015 ISSUED FOR CONSTRUCTION - MODIFICATIONS IF ANY ARE CLOUDED J.M.L
DATE
STEEL FOR BUILDINGS". REV. (dd/mm/yy) DESCRIPTION OF REVISION APP.

45
°
0.25t ≤ S ≤ 10
t
60° 0-3 NAME DATE (dd/mm/yyyy)
t
60° 1t/2 1t/2 DESIGNED BY: A.KORJIEH 15/12/2015
1t/2

0-3
1.5-3

DRAWN BY: E.BOU HABIB 15/12/2015


1-3

CHECKED BY:
t

H.BOITARD / M.DRAIEF 15/12/2015


1-3

0-3
0-3
S

0-3 APPROVED BY:


1-3

0-3

J.M.LEPEUVEDIC 15/12/2015
2t/3
0-3
t

45°
1-3

45°

0-3
t

45
°
S
0-3

1t/2

0.25t≤S≤10

0-3
t/3

°
0-3

45
1-3

0-3

Bahrain International Airport


6<t≤19 0.25t≤S≤10 S
6<t≤19
0.25t≤S≤10 S S
60° 19<t S
6<t≤19 19<t
19<t
AIRPORT MODERNIZATION PROGRAM
DETAIL "1" DETAIL "2" DETAIL "3" DETAIL "4" DETAIL "5" DETAIL "6"
SC. 1/5 SC. 1/5 SC. 1/5 SC. 1/5
SC. 1/5 SC. 1/5
CLIENT: CLIENT REPRESENTATIVE :

S
S t

4 PROJECT MANAGER: STAKEHOLDER SIGN-OFF:


1
1:4 TAPER
F
F

0.25t≤S≤10
DESIGN CONSULTANT: STRUCTURE & MEP DESIGN
CONSULTANT:

45
°
S
4
1
IN BUTT JOINTS WHERE THE ELEMENTS ARE PHASE & DISCIPLINE:
S

OF DIFFERENT THICKNESS OR WIDTH, A SLOPE


THROUGH THE TRANSITION ZONE NOT
CONSTRUCTION PHASE
t
t

EXCEEDING 1:4 SHALL BE MADE. THE


TRANSITION SHALL BE MADE BY : CHAMFERING
THE THICKER PART; TAPERING THE WIDER STRUCTURAL
0-3
1-3

PART; OR SLOPING THE WELD.


DRAWING TITLE:
PASSENGER TERMINAL BUILDING
0-3 F
F=1+0.1S

6<t≤19

DETAIL "9"
LEGEND & GENERAL NOTES
DETAIL "7" DETAIL "8"
TAPER DETAILS
SC. 1/5 SC. 1/5
SC. 1/5
STEEL

PROJECT NUMBER DRAWING NUMBER REV.


4351377
SCALE (A0) CP-B1000-S00-00060 A
NTS
KEY PLAN:

TR
UE
NO
RT
C H
A
C
ME
NON-LOAD BEARING WALL REINFORCEMENT
MASONRY GENERAL NOTES SPANNING VERTICALLY
WALL THICKNESS WALL HEIGHT (m)
t (mm) HORIZONTAL VERTICAL
1- CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE ACI 530-95 BUILDING CODE
REINFORCEMENT REINFORCEMENT TYPICAL CONNECTION DETAIL
REQUIREMENTS FOR CONCRETE MASONRY STRUCTURES.
2- CONCRETE MASONRY TO HAVE A MINIMUM 28-DAY CYLINDRICAL COMPRESSIVE STRENGTH f 'c =7 MPa, 100 H ≤ 5.0 #12 @ 400 MASONRY / STEEL

3- MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270, TYPE M BELOW GRADE AND TYPE S ABOVE GRADE. H ≤ 1.8
150 NONE
4- POURABLE CONSISTENCY GROUT SHALL BE USED TO FILL ANY REQUIRED CAVITIES AT BEAM, JOIST AND METAL DECK
LEGEND:
BEARING COURSES, AT VERTICAL FILL OF HOLLOW CELLS, BOND BEAMS, REINFORCED MASONRY BEAMS, PIERS AND 150 1.8 < H ≤ 4.0 #12 @ 1200 A
STEEL BEAM

COLUMNS. GROUT SHALL CONFORM TO ASTM C-476 WITH MINIMUM 28 DAY COMPRESSION STRENGTH OF 20 MPa.
5- STEEL BAR REINFORCEMENT SHALL CONFORM TO ASTM A615, GRADE 420 MPa. HORIZONTAL JOINT REINFORCEMENT 200 H ≤ 1.8 NONE - ALL DIMENSIONS ARE IN MILLIMETERS,LEVELS IN METERS,UNLESS
STATED OTHERWISE
BOLT M16 grd. 8.8
SHALL BE LADDER TYPE 1.8 < H ≤ 6.0
@ 1m

#12 @ 1200
6- VERTICAL CELLS CONTAINING REINFORCING AND GROUT SHALL FORM A CONTINUOUS CAVITY, FREE OF MORTAR DROPPINGS. L100x100x10
60 - DRAWING SHOULD NOT BE SCALED,FOLLOW WRITTEN DIMENSIONS
7- VERTICAL REINFORCING SHALL BE FULLY GROUTED IN THE CELLS OF THE CONCRETE MASONRY UNITS AND SHALL BE 200 6.0 < H ≤ 6.8 #12 @ 1000 ONLY.
LAPPED 48 BAR DIAMETERS BUT NOT LESS THAN 0.62 m. 50 -THIS DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE
THE VERTICAL REINFORCEMENT SHALL BE LAPPED WITH DOWELS OF SAME SIZE AND SPACING WHICH HAVE BEEN PREVIOUSLY 6.8 < H ≤ 7.0 #12 @ 800 CONCRETE LINTEL CONCRETE LINTEL MECHANICAL/HVAC/SANITARY PLANS ,THE FINAL SIZES AND LOCATIONS
A
OF FLOORS.
INSTALLED IN THE FOUNDATIONS. EMBEDMENT OF DOWELS SHALL CONFORM TO THE REQUIREMENTS OF ACI 318. H ≤ 1.8
MASONRY BLOCKS

250 NONE
8- LIFTS OF GROUT SHALL BE KEYED 0.1 m INTO THE PREVIOUS COURSE OF MASONRY BELOW. MASONRY BLOCKS
SECTION A-A
-ALL REINFORCED BARS SHALL BE DEFORMED HIGH STRENGTH AND
9- ALL MASONRY BELOW GRADE SHALL BE GROUTED SOLID. SHALL HAVE A MINIMUM YIELD STRENGTH OF 420 MPA.
250 1.8 < H ≤ 5.0 #12 @ 800
scl.1/20

10- PROVIDE DOWEL BARS IN SLAB ON GRADE FOR VERTICAL REINFORCING BARS IN CMU WALL. DOWEL BARS SHALL HAVE (2)- MW11.1 WIRES
-REINFORECD CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE
SAME SPACING AND SIZE OF VERTICAL REINFORCING BARS. 300 H ≤ 3.0 @400 O.C. MAX. NONE STRENGTH AS FOLLOW:
-COLUMNS & WALLS f'c=50 MPA.
11- INTERIOR NON-LOAD BEARING MASONRY WALLS SHALL BE LATERALLY BRACED AT UNDERSIDE OF FLOOR OR ROOF DECK AT 3.0 < H ≤ 7.0 #12 @ 1200 -PILES, FOOTINGS, SLABS & BEAMS f'c=40 MPA.
1.2 m MAXIMUM SPACING.
-ALL BLINDING CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE
300 7.0 < H ≤ 8.0 #12 @ 1000 STRENGTH OF 20 MPA.

8.0 < H ≤ 10.1 #12 @ 600 -THE MINIMUM PROTECTIVE CONCRETE COVER FOR REINFORCEMENT
SHALL BE AS FOLLOW:

-FOR GRADE BEAMS: 40mm


-FOR COLUMNS: 40mm
-FOR BEAMS: 40mm
-FOR INTERNAL WALLS NOT EXPOSED TO WEATHER: 25mm
-FOR EXTERNAL WALLS EXPOSED TO WEATHER: 40mm
-FOR WALLS EXPOSED TO EARTH: 50mm
-FOR WATER TANK WALLS :
LINTELS ABOVE MASONRY OPENINGS: LESS THAN 3000 LESS THAN 3000 -FOR SOLID SLAB:
50mm
25mm
-FOR SLAB ON GRADE: 40mm
OPENING -FOR FOOTINGS: 75mm
Length
(mm) 1500 2500 3500 5000
Width (mm) -PROJECT LEVEL ±0.00 EQUAL TO +2.90 TOPOGRAPHICAL LEVEL.

2T10

h < 2500
100 8@15
200

- - -
POST
100

< 1500
HI =
4T10 4T10 2T10 2T10 LINTEL

H (FLOOR HEIGHT)
8@15 8@15
200

250

8@15 2T10
450

LINTEL
350

150 8@15
150 150
150 2T14 150 2T16

4T10 4T10 2T10 2T10 OPENING


h < 2500

2
8@15 8@15 MAXIMUM AREA OF 9 m.
200

250

8@15 2T10
450
350

200 8@15
200 200 POST
200 2T14 200 2T16

2T10 2T10 2T10 2T10

8@15 8@15 2T10


200

250

450

8@15 POST & LINTEL ELEVATION @ OPENING


350

250 8@15 SCALE : NTS


2T12 2T12 2T14 TYPICAL POST & LINTEL ELEVATION
250 250 2T16
250 250 SCALE : NTS

-LINTELS SHALL BEAR ON MASONRY 40cm ON EACH SIDE OF OPENING.

POST 100x100 POST 150x150 POST 200x200


4T12 4T12 4T12 POST 250x250
REVISION:
100

150

200

250
8@200
8@200
100 8@200 A 15/12/2015 ISSUED FOR CONSTRUCTION - MODIFICATIONS IF ANY ARE CLOUDED J.M.L
DATE
REV. (dd/mm/yy) DESCRIPTION OF REVISION APP.

150
200
TYPICAL POST DETAILS 250
SCALE : NTS NAME DATE (dd/mm/yyyy)
DESIGNED BY: A.KORJIEH 15/12/2015
POST 100x100 POST 150x150 POST 200x200
4T12 4T12 4T12 POST 250x250 DRAWN BY: E.BOU HABIB 15/12/2015

CHECKED BY: H.BOITARD / M.DRAIEF 15/12/2015

APPROVED BY: J.M.LEPEUVEDIC 15/12/2015


100

150

200

250

100
150
8@200 200 Bahrain International Airport
8@200 250
AIRPORT MODERNIZATION PROGRAM
8@200
TYPICAL POST DETAILS CLIENT: CLIENT REPRESENTATIVE :
SCALE : NTS

PROJECT MANAGER: STAKEHOLDER SIGN-OFF:

DESIGN CONSULTANT: STRUCTURE & MEP DESIGN


CONSULTANT:

PHASE & DISCIPLINE:

CONSTRUCTION PHASE
STRUCTURAL
DRAWING TITLE:
PASSENGER TERMINAL BUILDING
LEGEND & GENERAL NOTES
MASONRY WALL

PROJECT NUMBER DRAWING NUMBER REV.


4351377
SCALE (A0) CP-B1000-S00-00070 A