Вы находитесь на странице: 1из 2

®

DSEGenset

DSE6010/20 MKII ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITY
AUTO START AND AUTO MAINS FAILURE BS EN 61000-6-2
EMC Generic Immunity Standard for
CONTROL MODULES the Industrial Environment
BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment
FEATURES
ELECTRICAL SAFETY
BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
The DSE6010 MKII Auto Start Electronic J1939 (CAN) and non- Using the DSE Configuration Suite
Control Module and the DSE6020 electronic MPU and alternator PC Software the controller is easy TEMPERATURE
MKII Auto Mains (Utility) Failure sensing engine support for diesel, to use and configure which allows BS EN 60068-2-1
Ab/Ae Cold Test -30 oC
Control Module are suitable for a gas and petrol engines all in one alteration of operating parameters, BS EN 60068-2-2
wide variety of single gen-set variant. With a number of flexible sequences, timers and alarms. Bb/Be Dry Heat +70 oC
applications. inputs, outputs and protections, the VIBRATION
modules can be easily adapted to BS EN 60068-2-6
Monitoring engine speed, oil suit a wide range of applications. AVAILABLE VARIANTS Ten sweeps in each of three
major axes
pressure, coolant temperature, 5 Hz to 8 Hz at +/-7.5 mm,
6010-03 Auto Start with real time clock
frequency, voltage, current, power Through USB Communication both 8 Hz to 500 Hz @ 2 GN
and fuel level, the modules give modules can be configured using 6010-04 Auto start with real time clock and HUMIDITY
comprehensive engine and the DSE Configuration Suite PC heated display BS EN 60068-2-30
alternator protection. This is Software or through the module's Db Damp Heat Cyclic 20/55 oC
at 95% RH 48 Hours
indicated on a large back-lit LCD front panel editor. 6020-03 Auto Mains Failure with real time BS EN 60068-2-78
icon display via an array of warning, clock Cab Damp Heat Static 40 oC
at 93% RH 48 Hours
electrical trip and shutdown alarms. 6020-04 Auto Mains Failure with real time
clock and heated display SHOCK
BS EN 60068-2-27
Three shocks in each of three major axes
15 GN in 11 mS

DEGREES OF PROTECTION
PROVIDED BY ENCLOSURES
BS EN 60529
IP65 - Front of module when installed into the
control panel with the optional sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

6 4 4

USB CONFIGURABLE DC OUTPUTS ANALOGUE SENSOR / EMERGENCY DC POWER


PORT INPUTS DIGITAL INPUT STOP SUPPLY 8-35V

DSE6010/20 MKII
7

OTHER

MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL & START ELECTRONIC
SENSING 1 OF 4 LOAD CURRENT 1 OF 4 SENSING ALTERNATOR OUTPUTS ENGINES &
(DSE6020 MKII) (Flexible with CAN) MAGNETIC PICK-UP

VOLTS VOLTS
+ D+
+ W/L +

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N
®

DSEGenset

DSE6010/20 MKII
SPECIFICATION

DC SUPPLY

AUTO START AND AUTO MAINS FAILURE CONTINUOUS VOLTAGE RATING


8 V to 35 V Continuous

CONTROL MODULES CRANKING DROPOUTS


Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
FEATURES without the need for internal batteries.
LEDs and backlight will not be maintained
during cranking.

DSE6020 MKII MAXIMUM OPERATING CURRENT


100 mA at 12 V, 105 mA at 24 V

MAXIMUM STANDBY CURRENT


60 mA at 12 V, 55 mA at 24 V

MAXIMUM SLEEP CURRENT


DSE6010 MKII 40 mA at 12 V, 35 mA at 24 V

GENERATOR & MAINS (UTILITY)


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

INPUTS
DIGITAL INPUTS A to F
Negative switching

ANALOGUE INPUTS A to C
Configurable as:

0 Ω to 480 Ω
Negative switching digital input

ANALOGUE INPUT D
Configurable as:
Negative switching digital input
KEY BENEFITS KEY FEATURES • Support for 0-10 V & 4-20 mA 0 V to 10 V

0 Ω to 480 Ω
4 mA to 20 mA
• Automatically transfers between • Large back-lit icon display oil pressure sensors
mains (utility) and generator • Heated display option available • Configurable staged loading
(DSE6020 MKII only) • Fully configurable via the fascia outputs OUTPUTS
OUTPUT A (FUEL)
• Hours counter provides accurate or PC using USB • CAN, MPU and alternator 10 A short term, 5 A continuous,
information for monitoring and communication speed sensing in one variant at supply voltage
maintenance periods • Efficient power save mode • 3 engine maintenance alarms
OUTPUT B (START)
• User-friendly set-up and button • 3 phase generator sensing • Engine speed protection 10 A short term, 5 A continuous,
layout for ease of use • 3 phase mains (utility) sensing • Engine hours counter at supply voltage
• Multiple parameters are (DSE6020 MKII only) • Engine pre-heat
AUXILIARY OUTPUTS C, D, E & F
monitored simultaneously which • Generator/load power • Engine run-time scheduler 2 A DC at supply voltage
are clearly displayed on a large monitoring (kW, kV A, kV Ar, pf) • Engine idle control for starting &
back-lit icon display • Accumulated power monitoring stopping DIMENSIONS
OVERALL
• The module can be configured (kW h, kVA h, kVAr h) • Fuel pump control 216 mm x 158 mm x 43 mm
to suit a wide range of • Generator overload protection • Real time clock 8.5’’ x 6.2” x 1.5”
applications (kW) • Battery voltage monitoring
PANEL CUT-OUT
• Compatible with a wide range • Generator/load current • Start on low battery voltage 184 mm x 137 mm
of CAN engines, including tier 4 monitoring and protection • Configurable remote start input 7.2’’ x 5.3”
engine support • Breaker control via fascia • 1 alternative configuration
MAXIMUM PANEL THICKNESS
• Uses DSE Configuration Suite buttons • Comprehensive warning, 8 mm
PC Software for simplified • Fuel and start outputs, electrical trip or shutdown 0.3”
configuration configurable when using CAN protection upon fault condition
STORAGE TEMPERATURE RANGE
• Licence-free PC software • 4 configurable DC outputs • LCD and LED alarm indication
-40 °F to +185 °F
-40°C to +85°C
• IP65 rating (with optional • 4 configurable analogue/digital • Configurable event log (50)
gasket) offers increased inputs
OPERATING TEMPERATURE RANGE
resistance to water ingress • 6 configurable digital inputs
-22 °F to +158 °F
-30°C to +70°C

-40 °C to +70 °C
RELATED MATERIALS HEATED DISPLAY VARIANT

-40 °F to +158 °F
TITLE PART NO’S
DSE6010/20 MKII Installation Instructions 053-174
DSE6010/20 MKII Operator Manual 057-230
DSE6010/20 MKII Configuration Suite PC Manual 057-223 OPTIONAL PARTS

PART PART NUMBER


IP65 Gasket 020-521

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-190/05/14 (2)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

Вам также может понравиться