Вы находитесь на странице: 1из 6

DYNEX High Pressure Hydraulics

ENGINEERING
SPECIFICATIONS

PF4300 SERIES
Checkball Piston Pumps 2.2 to 8.2 gpm (8,3 to 31,0 L/min) at 1800 rpm
For Water-Based Fluids 8000 to 15 000 psi (560 to 1040 bar)

Fixed displacement checkball pumps


are compatible with a variety of water-
based and other low-lubricity fluids.
Bi-directional shaft rotation provides
constant direction of output flow
regardless of drive shaft rotation.

MAINTENANCE-FREE DESIGN
The single-fluid checkball design uses
the pumped fluid for internal bearing
lubrication. This eliminates the potential
for fluid cross-contamination, possible in
other designs with isolated lubrication. It
also avoids the cost of a lubrication circuit.

RELIABLE HIGH PRESSURE


Individual piston check valves provide
long service life and greater volumetric
efficiency, especially at high pressures
and with low-lubricity fluids.
The check valves take the place of a
valveplate in other pump designs. With
no rotating sealing surface, checkball Specifications
pumps are resistant to wearing and
scoring. Output Flow Output Flow Output Flow
at 1200 rpm at 1500 rpm at 1800 rpm Maximum
Pressure Min. Maximum
TYPICAL APPLICATIONS Pump U.S. U.S. U.S. Speed Speed
Models gpm L/min gpm L/min gpm L/min psi bar rpm rpm
These pumps are ideal for use in wellhead
PF4303 1.5 5,6 1.8 6,9 2.2 8,3 8000 560 900 1800
safety control systems and other subsea
applications, providing long life operating PF4304 2.1 8,1 2.7 10,1 3.2 12,1 8000 560 900 1800
at high pressures with water-based fluids. PF4305 2.5 9,3 3.1 11,7 3.7 14,0 8000 560 900 1800
PF4306 2.9 11,0 3.6 13,6 4.4 16,6 8000 560 900 1800
They are also used on hydroform
PF4308 3.6 13,6 4.5 17,0 5.4 20,4 8000 560 900 1800
presses, and other applications requiring
environmentally-friendly or fire-resistant PF4309 4.0 15,1 5.0 18,9 6.0 22,7 8000 560 900 1800
fluids. PF4310 4.5 17,1 5.7 21,4 6.8 25,7 8000 560 900 1800
PF4312 5.5 20,7 6.8 25,9 8.2 31,0 8000 560 900 1800
PUMP SELECTION PF4303H 1.3 4,8 1.6 6,2 2.0 7,5 15 000 1040 900 1800
PF4304H 2.0 7,6 2.5 9,5 3.1 11,7 12 000 830 900 1800
The table shows specifications for
PF4305H 2.3 8,9 2.9 11,0 3.6 13,6 10 000 700 900 1800
standard pressure models, and for high
pressure “H” option models for maximum PF4306H 2.9 11,0 3.6 13,6 4.4 16,6 10 000 700 900 1800
pressures to 15 000 psi (1040 bar). The “H” PF4308H 3.5 13,2 4.3 16,5 5.3 19,9 10 000 700 900 1800
option requires high pressure coned and PF4309H 3.9 14,7 4.8 18,2 5.9 22,3 10 000 700 900 1800
threaded or B.S.P. outlet ports. PF4310H 4.4 16,7 5.5 21,0 6.7 25,3 10 000 700 900 1800
PF4312H 5.4 20,4 6.7 25,6 8.1 30,7 10 000 700 900 1800
Refer to “Typical Model Code” to specify
shaft, seal and outlet port options.  Output flow based on typical performance using 33 SUS (1,9 cSt) water glycol fluid at maximum pressure
with pressurized inlet where required. Refer to the “Minimum Inlet Pressure” table on page 2.
 Contact the sales department for operation below 900 rpm.
INSTALLATION AND OPERATING Minimum Inlet Pressure 
Refer to separate Bulletin PSI.CB for IMPORTANT: Pumps may require pressurized inlet conditions at higher speeds.
general installation and operating Failure to meet minimum inlet requirements will result in flow reduction. Refer to the table.
recommendations.
Operating Speed
All dimensions are shown in inches
Pump 1200 rpm 1500 rpm 1800 rpm
(millimeters in parentheses) and are
Models
nominal. psi bar psi bar psi bar
Note that Models PF4303 and PF4304 PF4303,
0 0 0 0 0 0
have three pistons; Models PF4305, PF4305 and PF4306
PF4308, PF4309 and PF4310 have five PF4304 and PF4308 0 0 0 0 5 0,4
pistons; and Models PF4306 and PF4312 PF4309 0 0 5 0,4 10 0,7
have six pistons. PF4310 0 0 5 0,4 15 1,0
PF4312 0 0 5 0,4 15 1,0
Mounting
 Values shown are based on fluid viscosity of 33 SUS (1,9 cSt).
S.A.E. D 4-bolt pattern with 0.25 inch
(6,4 mm) pilot engagement.

Shaft Options Hydraulic Fluid Viscosity Guidelines


Standard keyed shaft, 1.250 inch Operating
(31,75 mm) diameter;
Minimum Maximum Start-up
Optional spline shaft, 1.248/1.247 inch
diameter standard S.A.E. 14 tooth, SUS cSt SUS cSt SUS cSt
12/24 D.P. 30° involute spline. 32 1,5 927 200 927 200
 If fluid conditions fall outside of the range shown, contact the sales department.
Outlet Port Options
Standard pressure models have S.A.E.
ports. High pressure “H” option models
require the use of outlet port option “A” Seal Options FLUID RECOMMENDATIONS
(Autoclave Medium Pressure, Butech Nitrile.
M/P or equivalent fittings), or outlet port Fluorocarbon (Viton® or Fluorel®). Special Fluid Operation
option “B” (British Standard Pipe fittings). EPR (for use with some phosphate ester Because of the wide range of water-based
As shown, the outlet port on these fluids). fluid characteristics, contact the sales
pumps is machined in a block integrally department for a review of the application
mounted to the pump barrel. Refer
Minimum Filtration Levels requiring non-petroleum based fluid.
to “Typical Model Code” on page 4 to Pump inlet: 150 µ nominal;
specify the port. Pressure or return line: 25 µ nominal. Viscosity Specifications
While finer filtration levels than these Using fluid with the correct viscosity
Orientation/Drive are desirable and will result in longer range is critical to achieving long
Shaft horizontal with inlet vertically up component life, restricting flow to the component life.
is preferred. Vertical shaft mounting is pump inlet should be avoided. Minimum Fluid conditions outside the ranges
possible, but requires connecting a line recommended inlet conditions must be shown in the table may result in reduced
to the bleed port in the pump housing. maintained. pump output, requiring pressurized inlet
Contact the sales department for more conditions. For more information, contact
information. Weight (Mass) the sales department.
116 lb (53 kg)

OUTLET PORT — NO. 8 S.A.E.;


6.364 9.93 OR 9/16 MEDIUM PRESSURE CONED AND THREADED,
(161,6) (252,2) .8125–16 U.N.–2B THREADED (AUTOCLAVE MEDIUM
3.182 PRESSURE, BUTECH M/P, OR EQUIVALENT);
4.06 INLET PORT OR G 1/2 (B.S.P.P.)
(80,82)
SQUARE KEY (103,1) NO. 24 S.A.E.
.31 X 1.18 (7,9 X 30,0) .13
(3,4) 5.18 CONED AND
4.62 (131,6) THREADED PORT
(117,3)
(
1.392 35,36
1.384 35,15 ) 5.09
(129,3)
S.A.E. OR
B.S.P.P. PORT
∅ 6.000
5.998

(152,40
152,35 )
3.13
∅ 1.250 31,75
1.248 31,70( )
(79,4)

∅ .812 (20,62)
.25 1.50 .50
8.00 4 MOUNTING HOLES (38,1)
(203,2) (6,4) .58 (12,7)
.75 (14,7) ∅ 7.50
BLEED PORTS (3) — NO. 6 S.A.E., 90° APART
(19,0) (190,5)
2.25 10.73 BLEED PORT FOR
(57,2) (272,5) VERTICAL MOUNTING — NO. 4 S.A.E.

2
Typical Performance Curves
IMPORTANT: Typical performance curves are based on 33 SUS (1,9 cSt) water glycol fluid. Pumps may require pressurized inlet conditions
at higher speeds. Failure to meet minimum inlet requirements will result in flow reduction. Refer to the table on page 2.

 Contact the sales department for operation below 900 rpm.

3
TYPICAL MODEL CODE
PF43 03 H – S XV A – 20

Pump Type Ports

Fixed Displacement No Code Inlet No. 24 S.A.E.; Outlet No. 8 S.A.E.


PF43
Checkball Pump Inlet No. 24 S.A.E.; Outlet 9/16 Medium
A Pressure Coned and Threaded,
.8125-16 U.N.-2B Threaded
B Inlet No. 24 S.A.E.; Outlet G 1/2 (B.S.P.)➂ Design Number
Output Flow
(At 1800 rpm, at  Not recommended for operation above 8000 psi (560 bar).
maximum pressure) Contact the fitting manufacturer for the pressure rating
of the fitting.
Standard: 2.2 gpm (8,3 L/min)
03  High pressure port uses Autoclave Medium Pressure,
“H” Option: 2.0 gpm (7,5 L/min) Butech M/P or equivalent fitting.
Standard: 3.2 gpm (12,1 L/min) ➂ Outlet port uses British Standard Pipe fitting. Not
04
“H” Option: 3.1 gpm (11,7 L/min) recommended for operation above 10 000 psi (700 bar).
Standard: 3.7 gpm (14,0 L/min)
05
“H” Option: 3.6 gpm (13,6 L/min)
Standard: 4.4 gpm (16,6 L/min) Seals
06
“H” Option: 4.4 gpm (16,6 L/min) No Code All Nitrile
Standard: 5.4 gpm (20,4 L/min) XE All EPR with High Pressure Shaft Seal
08
“H” Option: 5.3 gpm (19,9 L/min)
XV All Fluorocarbon (Viton® or Fluorel®) with High Pressure Shaft Seal
Standard: 6.0 gpm (22,7 L/min)
09
“H” Option: 5.9 gpm (22,3 L/min)  Contact the sales department for recommended operating conditions for any
application using non-petroleum based fluids.
Standard: 6.8 gpm (25,7 L/min)
10
“H” Option: 6.7 gpm (25,3 L/min)
Standard: 8.2 gpm (31,0 L/min)
12 Drive Shaft
“H” Option: 8.1 gpm (30,7 L/min)
No Code Keyed, 1.250 inch (31,75 mm) diameter
 Output flows based on typical perform-
ance at maximum pressure. Refer to S S.A.E. Spline, 1.250 inch (31,75 mm)
performance curves for flows at lower
pressures.
 Models PF4303 and PF4304 have Operating Pressure
three pistons; Models PF4305, PF4308,
PF4309 and PF4310 have five pistons; No Code Standard Pressure
Models PF4306 and PF4312 have six
pistons. H High Pressure
 Requires “A” or “B” port option.

Specifications shown were in effect when printed. Since errors or omissions are
possible, contact your sales representative or the sales department for the most
current specifications before ordering. Dynex reserves the right to discontinue
products or change designs at any time without incurring any obligation.

www.dynexhydraulics.com

USA Headquarters Power Units & Systems European Sales


770 Capitol Drive 54 Nickerson Road Unit C5 Steel Close, Little End Road,
Pewaukee, WI 53072 Ashland, MA 01721 Eaton Socon, St Neots,
Tel: 1-262-691-2222 Tel: 1-508-881-5110 Cambs. PE19 8TT United Kingdom
FAX: 1-262-691-0312 FAX: 1-508-881-6849 Tel:+44 (0) 1480 213980 FAX:+44 (0) 1480 405662
E-mail: sales@dynexhydraulics.com E-mail: sales@ashland.dynexhydraulics.com E-mail: sales@dynexhydraulics.co.uk

Copyright © Dynex/Rivett Inc. Printed in U.S.A. Bulletin PES.PF4300-0716


FLUID RECOMMENDATIONS Hydraulic Fluid Viscosity
(All Checkball Pumps) Operating
Minimum Maximum Start-up Optimum
Mineral Oil Pump
A high-grade premium petroleum-based Models SUS cSt SUS cSt SUS cSt SUS cSt
fluid should be used to assure long Fixed Displacement Pumps:
component and system life. The fluid PF500-10 52 8 1911 413 3706 800 98 to 324 20 to 70
should have a combination of anti-wear,
PF1000-10 59 1,3 1911 413 3706 800 98 to 324 20 to 70
demulsibility, rust protection, oxidation-
resistant and foam-resistant properties. PF1300-10 31 10 927 200 927 200 – –
PF2000 59 10 1911 413 1911 413 98 to 324 20 to 70
Special Fluids PF2000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
Various pump models are available
PF3000-10 59 10 1911 413 3706 800 98 to 342 20 to 70
for use with water-based fluids, diesel
calibration fluids, phosphate ester fluids, PF4000-30 34 2,3 1911 413 1911 413 98 to 324 20 to 70
machining coolant, brake fluid, various PF4200-10 34 2,3 1911 413 1911 413 98 to 324 20 to 70
military fluids and other special fluids. PF4300-20 31 1,5 927 200 927 200 – –
PF1300 & PF4300 Series pumps are PF6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
compatible with a variety of water-
Mechanical Variable Delivery Pumps:
based fluids. Refer to specific product
documentation for specifications for PV4000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
these models, which are specifically rated PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
for use with low-lubricity fluids. Hydraulic Variable Delivery Pumps:
Some pump models may require reduced PV6000 34 2,3 1911 413 1911 413 98 to 324 20 to 70
operating pressures when using low-
 Fluid conditions outside the “Optimum” range may result in reduced output, requiring pressurized inlet
lubricity fluids. conditions. Contact the sales department.
Because of the wide range of fluid  Models with special mounting.

characteristics, contact the sales depart-


ment for a review of any application using
non-petroleum based fluids. MINIMUM FILTRATION LEVELS INSTALLATION AND OPERATION
Viscosity Specifications Pump inlet: 150 µ nominal; Refer to separate Bulletin: Checkball
Using fluid with the correct viscosity Pressure or return line: 25 µ nominal. Pumps Service, Installation and Operating
range is critical to achieving long Instructions for general installation and
component life. While finer filtration levels than these operating recommendations.
are desirable and will result in longer
Fluid conditions outside the “Optimum” component life, restricting flow to the That brochure includes information on
range shown in the table may result pump inlet should be avoided. Minimum mounting, shaft loading, sizing inlet pipe
in reduced pump output, requiring recommended inlet conditions must be and hose, air bleed procedures and initial
pressurized inlet conditions. For maintained. start-up. Guidelines for maintenance,
more information, contact the sales repair and trouble-shooting are also
department. If a system component fails resulting in included.
fluid contamination, it is important to
drain and clean the reservoir, all lines,
filter screens and all components. Refill
with new fluid.

5
OULET PORT CONFIGURATIONS Coned and Threaded Ports The recommended fitting has a recessed
seal cavity formed by a shoulder on the
Dynex pumps are available with outlet underside of the flanged wrench flat
ports suitable for use at various pressure TUBING (Voss “Peflex”, Form B Shoulder Seal;
GLAND NUT
ranges. Refer to the appropriate or Parker Type E, “EOlastic” Seal; or
“Specification Table” or “Typical Model equivalent).
Code” to specify the required port. B.S.P. ports are not recommended for
Contact the fitting manufacturer to SLEEVE
operation above 10 000 psi (700 bar).
ensure the selected fittings are rated for Contact the fitting manufacturer, to
WEEP
the maximum pump operating pressure. PUMP
HOLE ensure the selected fittings are rated for
COVER
the maximum pump operating pressure.

S.A.E. Straight Thread Ports Typical Coned and Threaded


port connection S.A.E. 4-Bolt Flange Ports
High-pressure pumps are available with
COUPLING
coned and threaded outlet ports, which FLANGE
use Autoclave Medium Pressure, Butech
BOLTS
M/P, or equivalent fittings.
O-RING
These fittings provide a metal-to-metal
seal with an interference fit, not requiring O-RING
PUMP an o-ring. The gland nut holds the sleeve
COVER
and tubing against the cone surface. PUMP
COVER
A weep hole, visible on the outside of
Typical S.A.E. Straight Thread the pump cover, acts as an indicator of
port connection Typical S.A.E. 4-Bolt Flange
any abnormal leakage caused by system
port connection
The Straight Thread connection (S.A.E. conditions (i.e., excessive pressure). It
J1926/1) is sometimes referred to as an allows any fluid which does leak past the Flange connections are often used
S.A.E. O-ring Boss, or ORB. The port consists sealing surfaces to escape, preventing for higher flows requiring larger
of a machined spotface surface, a tapered pressure build-up and possible damage. diameter tubing. The port consists of an
seal cavity and a straight thread port. unthreaded port with four bolt holes in a
The fitting forms a seal by compressing rectangular pattern on a machined face
British Standard Pipe Ports around the port (S.A.E. J518).
the o-ring in the seal cavity with the
underside of the flanged wrench flat. A typical fitting consists of a flanged head
Some adjustable fittings, such as elbows COUPLING with a welded tube and a captive flange
and tees, use a locknut with a captive with bolt holes. A seal is formed by an
backup washer for compression. SEAL RING
o-ring in the groove on the underside
S.A.E. Straight Thread ports are not mounting surface of the flange head. As
recommended for operation above the flange bolts are alternately tightened,
8000 psi (560 bar). Also, the maximum
SHOULDER the o-ring is compressed between the
pressure of pumps with No. 12 S.A.E. PUMP
flange head and the machined face on
outlet ports may be limited by the
COVER the pump.
pressure rating of the available fitting. To make mounting easier in tight spaces a
Contact the fitting manufacturer for Typical port connection with two-piece split-flange is often used.
ratings. British Standard Pipe (Parallel)
fitting with shoulder

High-pressure pumps are available with


flat face ports with British Standard Pipe
(B.S.P.) parallel threads (BS 2779 or ISO
228), ideal for use on some European
applications.
The fitting forms a seal by compressing
a flat elastomer ring on a machined
spotface surface. There are several sealing
methods for these ports.