Вы находитесь на странице: 1из 6

System Configuration: Oracle Corporation sun4v SPARC Enterprise T5220

Memory size: 32640 Megabytes

================================ Virtual CPUs ================================

CPU ID Frequency Implementation Status


------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
8 1165 MHz SUNW,UltraSPARC-T2 on-line
9 1165 MHz SUNW,UltraSPARC-T2 on-line
10 1165 MHz SUNW,UltraSPARC-T2 on-line
11 1165 MHz SUNW,UltraSPARC-T2 on-line
12 1165 MHz SUNW,UltraSPARC-T2 on-line
13 1165 MHz SUNW,UltraSPARC-T2 on-line
14 1165 MHz SUNW,UltraSPARC-T2 on-line
15 1165 MHz SUNW,UltraSPARC-T2 on-line
16 1165 MHz SUNW,UltraSPARC-T2 on-line
17 1165 MHz SUNW,UltraSPARC-T2 on-line
18 1165 MHz SUNW,UltraSPARC-T2 on-line
19 1165 MHz SUNW,UltraSPARC-T2 on-line
20 1165 MHz SUNW,UltraSPARC-T2 on-line
21 1165 MHz SUNW,UltraSPARC-T2 on-line
22 1165 MHz SUNW,UltraSPARC-T2 on-line
23 1165 MHz SUNW,UltraSPARC-T2 on-line
24 1165 MHz SUNW,UltraSPARC-T2 on-line
25 1165 MHz SUNW,UltraSPARC-T2 on-line
26 1165 MHz SUNW,UltraSPARC-T2 on-line
27 1165 MHz SUNW,UltraSPARC-T2 on-line
28 1165 MHz SUNW,UltraSPARC-T2 on-line
29 1165 MHz SUNW,UltraSPARC-T2 on-line
30 1165 MHz SUNW,UltraSPARC-T2 on-line
31 1165 MHz SUNW,UltraSPARC-T2 on-line
32 1165 MHz SUNW,UltraSPARC-T2 on-line
33 1165 MHz SUNW,UltraSPARC-T2 on-line
34 1165 MHz SUNW,UltraSPARC-T2 on-line
35 1165 MHz SUNW,UltraSPARC-T2 on-line
36 1165 MHz SUNW,UltraSPARC-T2 on-line
37 1165 MHz SUNW,UltraSPARC-T2 on-line
38 1165 MHz SUNW,UltraSPARC-T2 on-line
39 1165 MHz SUNW,UltraSPARC-T2 on-line
40 1165 MHz SUNW,UltraSPARC-T2 on-line
41 1165 MHz SUNW,UltraSPARC-T2 on-line
42 1165 MHz SUNW,UltraSPARC-T2 on-line
43 1165 MHz SUNW,UltraSPARC-T2 on-line
44 1165 MHz SUNW,UltraSPARC-T2 on-line
45 1165 MHz SUNW,UltraSPARC-T2 on-line
46 1165 MHz SUNW,UltraSPARC-T2 on-line
47 1165 MHz SUNW,UltraSPARC-T2 on-line
48 1165 MHz SUNW,UltraSPARC-T2 on-line
49 1165 MHz SUNW,UltraSPARC-T2 on-line
50 1165 MHz SUNW,UltraSPARC-T2 on-line
51 1165 MHz SUNW,UltraSPARC-T2 on-line
52 1165 MHz SUNW,UltraSPARC-T2 on-line
53 1165 MHz SUNW,UltraSPARC-T2 on-line
54 1165 MHz SUNW,UltraSPARC-T2 on-line
55 1165 MHz SUNW,UltraSPARC-T2 on-line
56 1165 MHz SUNW,UltraSPARC-T2 on-line
57 1165 MHz SUNW,UltraSPARC-T2 on-line
58 1165 MHz SUNW,UltraSPARC-T2 on-line
59 1165 MHz SUNW,UltraSPARC-T2 on-line
60 1165 MHz SUNW,UltraSPARC-T2 on-line
61 1165 MHz SUNW,UltraSPARC-T2 on-line
62 1165 MHz SUNW,UltraSPARC-T2 on-line
63 1165 MHz SUNW,UltraSPARC-T2 on-line

======================= Physical Memory Configuration ========================


Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 32 GB 8 4 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
4 GB MB/CMP0/BR0/CH0/D1
MB/CMP0/BR0/CH1/D1
4 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
4 GB MB/CMP0/BR1/CH0/D1
MB/CMP0/BR1/CH1/D1
4 GB MB/CMP0/BR2/CH0/D0
MB/CMP0/BR2/CH1/D0
4 GB MB/CMP0/BR2/CH0/D1
MB/CMP0/BR2/CH1/D1
4 GB MB/CMP0/BR3/CH0/D0
MB/CMP0/BR3/CH1/D0
4 GB MB/CMP0/BR3/CH0/D1
MB/CMP0/BR3/CH1/D1

================================= IO Devices =================================


Slot + Bus Name + Model Speed
Status Type Path
------------------------------------------------------------------------------
MB/NET0 PCIE network-pciex8086,105e 2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0
MB/NET1 PCIE network-pciex8086,105e 2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1
MB/NET2 PCIE network-pciex8086,105e 2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0
MB/NET3 PCIE network-pciex8086,105e 2.5GTx4
/pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1
MB/SASHBA PCIE scsi-pciex1000,58 LSI,1068E 2.5GTx4
/pci@0/pci@0/pci@2/scsi@0
MB/RISER1/PCIE4 PCIE network-pciex108e,abcd SUNW,pcie-qgc 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@2/network@0
MB/RISER1/PCIE4 PCIE network-pciex108e,abcd SUNW,pcie-qgc 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@2/network@0,1
MB/RISER1/PCIE4 PCIE network-pciex108e,abcd SUNW,pcie-qgc 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@2/network@0,2
MB/RISER1/PCIE4 PCIE network-pciex108e,abcd SUNW,pcie-qgc 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@2/network@0,3
MB/RISER2/PCIE5 PCIE lpfc-pciex10df,fe00 LPe11002-M4 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@8/lpfc@0
MB/RISER2/PCIE5 PCIE lpfc-pciex10df,fe00 LPe11002-M4 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@8/lpfc@0,1
MB/RISER0/PCIE0 PCIE lpfc-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@9/lpfc@0
MB/RISER0/PCIE0 PCIE lpfc-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@9/lpfc@0,1
MB/RISER0/PCIE3 PCIE fibre-channel-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@a/fibre-channel@0
MB/RISER0/PCIE3 PCIE fibre-channel-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@8/pci@0/pci@a/fibre-channel@0,1
MB/RISER2/PCIE2 PCIE lpfc-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@9/lpfc@0
MB/RISER2/PCIE2 PCIE lpfc-pciex10df,fe00 LPe11002-E 2.5GTx4
/pci@0/pci@0/pci@9/lpfc@0,1
MB PCIX usb-pciclass,0c0310 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0
MB PCIX usb-pciclass,0c0310 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,1
MB PCIX usb-pciclass,0c0320 --
/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2

============================ Environmental Status ============================


Fan sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/FANBD0/FM0/F0 TACH ok
SYS/FANBD0/FM0/F1 TACH ok
SYS/FANBD0/FM1/F0 TACH ok
SYS/FANBD0/FM1/F1 TACH ok
SYS/FANBD0/FM2/F0 TACH ok
SYS/FANBD0/FM2/F1 TACH ok

Fan indicators:
----------------------------------------------------------------
Location Sensor Condition
----------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok

Temperature sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB T_AMB ok
SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok
SYS/MB/CMP0 T_TCORE ok
SYS/MB/CMP0 T_BCORE ok

Temperature indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok

Current sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/PS0 I_IN_MAIN ok
SYS/PS0 I_IN_LIMIT ok
SYS/PS0 I_OUT_MAIN ok
SYS/PS0 I_OUT_LIMIT ok
SYS/PS1 I_IN_MAIN ok
SYS/PS1 I_IN_LIMIT ok
SYS/PS1 I_OUT_MAIN ok
SYS/PS1 I_OUT_LIMIT ok

Current indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/MB I_USB0 ok
SYS/MB I_USB1 ok
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok

Voltage sensors:
----------------------------------------------------------------
Location Sensor Status
----------------------------------------------------------------
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_+3V3_STBY ok
SYS/MB V_VCORE ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN ok
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN ok
SYS/PS1 V_OUT_MAIN ok

Voltage indicators:
----------------------------------------------------------------
Location Indicator Condition
----------------------------------------------------------------
SYS/MB VCORE_POK ok
SYS/MB VMEML_POK ok
SYS/MB VMEMR_POK ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK ok
SYS/PS1 DC_POK ok
SYS/PS1 VOLT_FAULT ok

LEDs:
----------------------------------------------------------------
Location LED State
----------------------------------------------------------------
SYS SERVICE steady
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CMP0/BR0/CH0/D1 SERVICE off
SYS/MB/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CMP0/BR0/CH1/D1 SERVICE off
SYS/MB/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CMP0/BR1/CH0/D1 SERVICE off
SYS/MB/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CMP0/BR1/CH1/D1 SERVICE off
SYS/MB/CMP0/BR2/CH0/D0 SERVICE off
SYS/MB/CMP0/BR2/CH0/D1 SERVICE off
SYS/MB/CMP0/BR2/CH1/D0 SERVICE off
SYS/MB/CMP0/BR2/CH1/D1 SERVICE off
SYS/MB/CMP0/BR3/CH0/D0 SERVICE off
SYS/MB/CMP0/BR3/CH0/D1 SERVICE off
SYS/MB/CMP0/BR3/CH1/D0 SERVICE off
SYS/MB/CMP0/BR3/CH1/D1 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
SYS/HDD4 SERVICE off
SYS/HDD4 OK2RM off
SYS/HDD5 SERVICE off
SYS/HDD5 OK2RM off
SYS/HDD6 SERVICE off
SYS/HDD6 OK2RM off
SYS/HDD7 SERVICE off
SYS/HDD7 OK2RM off
SYS/FANBD0/FM0 SERVICE off
SYS/FANBD0/FM1 SERVICE off
SYS/FANBD0/FM2 SERVICE off

============================ FRU Status ============================


Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB RISER0 enabled
SYS/MB RISER1 enabled
SYS/MB RISER2 enabled
SYS/MB SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0 D0 enabled
SYS/MB/CMP0/BR0/CH0 D1 enabled
SYS/MB/CMP0/BR0/CH1 D0 enabled
SYS/MB/CMP0/BR0/CH1 D1 enabled
SYS/MB/CMP0/BR1/CH0 D0 enabled
SYS/MB/CMP0/BR1/CH0 D1 enabled
SYS/MB/CMP0/BR1/CH1 D0 enabled
SYS/MB/CMP0/BR1/CH1 D1 enabled
SYS/MB/CMP0/BR2/CH0 D0 enabled
SYS/MB/CMP0/BR2/CH0 D1 enabled
SYS/MB/CMP0/BR2/CH1 D0 enabled
SYS/MB/CMP0/BR2/CH1 D1 enabled
SYS/MB/CMP0/BR3/CH0 D0 enabled
SYS/MB/CMP0/BR3/CH0 D1 enabled
SYS/MB/CMP0/BR3/CH1 D0 enabled
SYS/MB/CMP0/BR3/CH1 D1 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 enabled
SYS HDD3 enabled
SYS HDD4 Not present
SYS HDD5 Not present
SYS HDD6 Not present
SYS HDD7 Not present
SYS PDB enabled
SYS SASBP enabled
SYS DVD enabled
SYS USBBD enabled
SYS FANBD0 enabled
SYS/FANBD0 FM0 enabled
SYS/FANBD0 FM1 enabled
SYS/FANBD0 FM2 enabled
SYS FANBD1 enabled
SYS PS0 enabled
SYS PS1 enabled

============================ FW Version ============================


Version
------------------------------------------------------------
Sun System Firmware 7.4.11 2017/05/04 15:31

====================== System PROM revisions =======================


Version
------------------------------------------------------------
OBP 4.33.6.h 2017/05/04 14:22

Chassis Serial Number


---------------------
BEL09208K7
***********************************