AMETank version 10.9 2
Fixes:
1. An error was occurring while loading some of the old models, the issue has been
resolved.
2. Update in API-650 metric version, rafter structure in a multiple bay configuration was
oversized due to wrong weight calculation, the issue has been resolved.
3. Update in API-650 self supported roof with high temperature (Annex M), the modification
factor for high temperature was not correct, it was undersizing the plate, the issue has
been resolved.
Enhancements:
1. Include the nominal and corroded section properties for the structural members in the
calculation report.
2. Add minimum thickness checks based on API-650 5.10.2.4
3. Update the calculation report descriptions for several components to make it more
readable.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. Dome structure calculation US units, the rafter required section modulus is not correct.
3
Fixes:
1. Update in dome structure calculation US units, the rafter required section modulus was
not correct, the issue has been resolved.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
4
Fixes:
Enhancements:
1. Add calculation warnings for single deck pontoon floating roof deck leg design.
2. Add calculation outputs to the user interface for the single deck pontoon floating roof.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. AWWA snow load is not used correctly, the user should enter the roof design snow load
instead of the ground snow load and it should not be reduced like API-650
5
Fixes:
1. Update API-620 Knuckle area calculation, it was understated, the issue has been
resolved.
2. Update AWWA to let the user enter the roof design snow load instead of ground snow
load, the entered value is not reduced like in API-650.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. When the tank is open top and a roof weight was added (in case the roof is a purchased
aluminum dome), the roof pressure due to wind is 0, it is understating the overturning
moment.
6
Fixes:
1. Fix intermediate stiffeners initialization, the initialize was not properly checking the cross
sectional area requirement.
2. Fix an error while generating the calculation report when using truss structure.
3. Intermediate stiffeners cross sectional area warnings in API-650 were shown in the
calculation report and not in the user interface, issue has been resolved.
Enhancements:
1. Clarify API-650 shell calculation warnings in the calculation report.
2. Add center column top component calculation for circular plate style.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. API-620 head with knuckle calculation is not considering the API-620 5.4.2 g) load case
for hydrostatic test.
3. When the tank is open top and a roof weight was added (in case the roof is a purchased
aluminum dome), the roof pressure due to wind is 0, it is understating the overturning
moment.
7
Fixes:
1. Due to a recent update, the MDMT warning were not showing on the API-650 shell
calculation, issue has been resolved.
2. Fix an error in EN-14015 when designing the outer ring in a structure without center
column.
3. Add frangible roof option when using pie segmented roof plate, this option was missing.
4. When the tank is open top and a roof weight was added (in case the roof is a purchased
aluminum dome), the roof pressure due to wind is 0, it is understating the overturning
moment. The issue has been resolved.
Enhancements:
1. Apply the minimum thickness (0.1" or 2.54mm) to shell re-rating as per API-653 4.3.3.1
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. API-620 head with knuckle calculation is not considering the API-620 5.4.2 g) load case
for hydrostatic test.
8
Fixes:
1. Fix an error in jack rafters with center column calculations, the error was happening
when editing the center column top component.
2. Fix an error related to MDMT, the error happens when the material is stainless steel or
carbon steel and the plate thickness is 3/16” or 5mm.
Enhancements:
1. Add column top plate and base plate calculations for jack rafters design with center
column.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. API-620 head with knuckle calculation is not considering the API-620 5.4.2 g) load case
for hydrostatic test.
9
Fixes:
1. Fix API-653 allowable stress for high temperature tanks per API-653 4.3.10.1. With the
new update all the shell courses will have the same allowable stress not exceeding .8
yield strength.
2. Fix an error in API-620 top member design when doing an open top tank.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. API-620 head with knuckle calculation is not considering the API-620 5.4.2 g) load case
for hydrostatic test.
10
Fixes:
1. Update API-620 head with knuckle calculation to consider all the load cases per API-620
5.4.2.
2. Remove MDMT warning when plate is set as impact tested.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
11
Fixes:
1. Fix an error in the top member design when using a cone roof.
Enhancements:
Known Issues:
API-620 Elevated bottoms and bottom member is not considering the hydrostatic test condition.
12
Fixes:
1. Top wind girder calculations for open top tanks has been updated per API-650 12th
edition addendum-2 section 5.9.6, for tanks in excess of 200ft (61m) diameter, the
diameter shall be considered to be 200ft (61m) when determining the section modulus.
Also a required moment of inertia has been added per section 5.9.6.2
2. The actual section modulus for the top wind girder was not correctly calculated, issue
has been resolved.
3. Unbalanced snow load in API-650 has been updated, for conical roof with a slope angle
less than or equal to 10 degrees, the unbalanced snow load should be equal to the
balanced per API-650 5.2.2.h.1.
Enhancements:
1. Remove MDMT check from the calculation report when impact tested is selected.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. The top wind girder section modulus value in the user interface does not show the
correct calculated value in the report. The calculation is correct, only the user interface
needs to be updated.
13
Fixes:
1. Shell course calculation using the variable design point method has been updated for
the third course. The variable tL in the calculation was using the design thickness from
the second course iterations and not the thickness calculated based on API-650 5.6.4.5.
2. Update AWWA annular ring requirements due to seismic loading per AWWA section
13.5.4.1.1 and 13.5.4.1.2. When J, stability ratio, is less than 0.785, there should be no
check for the maximum annular ring width.
3. Annular ring inside width in seismic calculation has been updated, the width should be
from the inside of the shell and any lap-welded joint in the remainder of the bottom per
API-650 5.1.5.4.3, AMETank was not deducting the overlap.
4. Update I-beam, C-channel, built-up I-beams and built-up C-channels column calculation.
The governing radius of gyration in the slenderness calculation was not using the
smallest one. The issue has been resolved.
5. Update rafter slenderness check for structure without columns. The member length
should be the unbraced length instead of the whole length.
6. Add rafter slenderness check for dome structure calculations.
7. Update API-650 maximum allowable working pressure based on Annex F. The equation
F.4.2 was using Mw (overturning moment about the shell-to-bottom joint from horizontal
plus vertical wind pressure) instead of Mws (overturning moment about the
shell-to-bottom joint from horizontal wind pressure). The issue has been resolved.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. The top wind girder section modulus value in the user interface does not show the
correct calculated value in the report. The calculation is correct, only the user interface
needs to be updated.
14
Fixes:
1. Stainless steel grades 304/304L/316/316L density has been updated to be: 0.29 lb/in^3
(8030 kg/m^3). It used to be 0.2975 lb/in^3 (8234 kg/m^3).
2. Update the top wind girder section modulus value in the user interface to show the
correct calculated value in the report.
Enhancements:
1. Update top member user interface. The labels has been updated to show more
descriptive information. Tooltips has been added.
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
15
Fixes:
1. Update API-650 bottom shell course rating (reverse calculation) for the VDP method. It
wasn’t using the governing thickness equation.
2. Update API-650 design parameters to apply Annex F when the design internal pressure
is greater than 2.5 psi or 18 kPa. A warning will be displayed in this case.
3. Update API-650 design parameters to apply Annex V when the design external pressure
is greater than 1 psi or 6.9 kPa. A warning will be displayed in this case.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
16
Fixes:
1. Update API-620 allowable stresses per section 5.5.3.3. The allowable stresses Sta shall
not exceed the product of the applicable joint efficiency for tension as given in Table 5-2
and the allowable stress for simple tension shown in Table 5-1.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
17
Fixes:
1. Update API-620 minimum required thickness per section 5.10.4.1. The minimum
thickness of any wall should not be less than 3/16” plus corrosion allowance.
2. Update API-620 maximum allowable compressive stress to use a joint efficiency of 1 if
the plates are butt welded as per Table 5-2 NOTE 2.
3. Update API-650 and API-653 shell rating when using the variable design point method.
The maximum allowable liquid level is now calculated based on iterations through liquid
levels instead of reversing the calculated thickness equation. The older method was not
working properly because each upper course is dependent on the course below it.
4. Update API-650 material yield strength. When annex X is applied, the yield strength was
not reduced for higher temperature per Table X.4. The issue has been resolved.
5. Update API-650 nozzle neck required thickness. When annex X is applied, the required
thickness was per Table 5-6 and not section X.3.4.1. The issue has been resolved.
6. Update API-620 roof design calculations to accounts for the liquid pressure if the liquid
level is beyond the shell height.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. Top member horizontal channel and double-angle were added recently but the
calculation is not validated yet.
18
Fixes:
1. Update AISC-360 allowable flexural strength to use the corroded member size when for
checking the slenderness.
Enhancements:
Known Issues:
1. API-620 Elevated bottoms and bottom member is not considering the hydrostatic test
condition.
2. Top member horizontal channel and double-angle were added recently but the
calculation is not validated yet.