SERIES 446
INSTALLATION
AND OPERATIONS GUIDE
Manual Number: DA072495
Revised: 9/24/09
Thank you for purchasing the Air Control Module. This manual contains information that will
allow you to get the best results from your equipment while operating it safely. Please read it
carefully before installing and operating this equipment. It is critical that the people operating
and maintaining this equipment have a copy of this manual. All information in this publication is
based on the latest product information. Dynamic Air Inc. reserves the right to make changes at
any time without notice and without incurring any obligation.
SAFETY MESSAGES
Your safety and the safety of others are very important. We have provided important safety
messages in this manual and safety labels on the equipment. Please read these messages
carefully.
A safety message alerts you to the potential hazards that could hurt you or others. Each safety
message is preceded by a safety alert symbol and one of three words, DANGER, WARNING,
or CAUTION.
This is the safety alert symbol. It is used to alert you to potential personal injury
hazards. Obey all safety messages that follow this symbol to avoid possible injury or
death.
Each message typically identifies the type of the hazard, the consequence of not avoiding the
hazard, and how to avoid the hazard.
Original Instructions
Safety Air Control Module
Series 446
Do Not Weld.
Risk of Explosion.
Original Instructions
Air Control Module
Table of Contents Series 446
Topic...................................................................................................... Section
Original Instructions
Operation Principles Air Control Module
Series 446
The Air Control Module (ACM) is the main pressure control device used in all "Dense Phase"
and some "Dilute Phase" pressure conveying systems. Although the word "Air" is used to
describe the ACM, it can be used with other inert gases such as Nitrogen.
This ACM design consists of multiple pilot operation regulators. The number of regulators is
based on the total flow requirement of the system.
These models are available in three configurations – single setpoint (-1), dual setpoint (-2)
and multi-pressure setpoint (-M). The single setpoint design uses one manual regulator for the
pressure control. The dual setpoint design uses two manual regulators and an additional 3-way
normally closed solenoid valve for selecting the desired pilot pressure. The multi-pressure
setpoint design uses an analog pressure controller. The pressure controller is available with a
0-10 VDC or 4-20 mADC analog signal which corresponds to a 0-100 psig (0-6.9 barg) output
pressure.
REGULATOR ANALOG
REGULATOR PRESSURE
REGULATOR
SOLENOID CONTROLLER
SOLENOID SOLENOID
NOTICE
Operating conditions
Dynamic Air's Air Control Module has a well-deserved reputation for giv-
ing long and dependable service, even under severe use. However, the Air
Control Module is intended for specific operating conditions only, with respect to air
pressure and volume. Because conditions for materials handled, installation, use and
maintenance of such products are controlled exclusively by the user, Dynamic Air dis-
claims all responsibility for damage or injury resulting from the use of the Air Control
Module. Therefore, the user assumes all responsibility for any and all claims arising
directly or indirectly from the product and/or its use.
NOTICE
1. Customer to supply clean, dry, compressed air at 95-100 psig (6.6-6.9 barg).
2. Prior to connecting the air supply line to the Air Control Module, make sure that all
compressed air supply lines are blown clean of metal chips and foreign debris.
3. Make sure that the air line connections are designed and installed to meet a minimum
operating pressure of 100 psig (6.9 barg).
4. Ensure the Air Control Module is piped and wired according to all drawings provided and
in accordance with all local and national codes.
5. A final electrical check of the Air Control Module should be performed to insure the proper
operation of the solenoid valve(s) and pressure transducer (where applicable).
DO NOT WELD
NOTICE
Operating conditions
Maximum operating pressure: 125 psig (8.6 barg)
Maximum operating temperature: 150° F (65.6° C)
Original Instructions
Section 3.1
Troubleshooting Air Control Module
Series 446
Original Instructions
Section 4.1
Maintenance Air Control Module
Series 446
WARNING
The parts and/or equipment purchased from Dynamic Air Inc. have a limited life that
depends on the user’s specific application and the conditions under which the user
operates the equipment. Over time, parts and equipment may suffer deterioration, wear
and tear, corrosion, or other failure. Therefore, the user must follow all instructions
contained in this notice and in the operating manuals provided by Dynamic Air Inc. for
each piece of equipment.
REQUIRED INSPECTIONS
The user of the Dynamic Air Inc. supplied parts and equipment should visually inspect
the entire system, parts or equipment at least once daily in order to detect potential
problems such as leaks, stress cracks, loosening of bolts and part failures, etc.
In addition, during the first start-up of the parts or equipment, specific data and settings
must be recorded in writing and be provided to all appropriate operating personnel for
their safe use in operating the system. This includes, but is not limited to, the following
operating data:
· Recommended air supply pressure · Convey times
· Air volume settings · Specific control settings
· Recommended air regulator · Valve settings
settings · Other applicable measurements
· Electrical interlocks · Motor amperage, etc.
· Recommended procedures · Timing sequences
· Weight limitations · Batch sizes
· Temperature limitations · Weighments
The operating data should be reviewed and, if necessary, adjusted accordingly on a daily,
weekly and monthly basis to insure that the parts or equipment is operating safely and
properly according to all the recommendations provided by Dynamic Air Inc.
Original Instructions
Section 5.1
Maintenance Air Control Module
Series 446
WARNING
SYSTEMS THAT REQUIRE IMMEDIATE SHUTDOWN AND INSPECTION
Whenever any unusual operating conditions or system functions or sudden changes in
such conditions or functions is noticed, the parts or equipment should be shut down
immediately and all air and electrical power should be shut off. Then, the equipment
should be thoroughly inspected to determine the cause of such conditions or symptoms
in order to protect personnel from potential injury and to protect the equipment from
potential damage or unsafe operating conditions. Conditions that require immediate
shutdown and inspection include but are not limited to excessive vibration, unusual
equipment movement, abnormal noise, excessive heat build-up, leaks, sudden loss of air
pressure, or sudden and unusual changes in temperature, noise, or an unusual amount
of material handled, etc.
SERVICE REQUIREMENTS
A Dynamic Air service technician must perform a thorough service inspection and
maintenance check of all Dynamic Air supplied parts or equipment at least once annually
in order to maximize equipment life and performance, minimize system downtime, protect
plant personnel, and minimize liability. It will be the user’s responsibility to schedule
these services as required. Failure to follow this requirement could cause damage to
equipment and endanger plant personnel. Should the user fail to operate the system
according to all instructions in the operating manuals, the warranty will be invalidated.
Original Instructions
Section 5.2
Maintenance Air Control Module
Series 446
WARNING
Disconnect and lockout/tagout all energy sources before performing
any maintenance.
Solenoid Valves:
• Keep the supply air flowing through the valve as free from dirt and foreign material as
possible. Check supply air pressure weekly.
• All solenoid valves should be cleaned periodically. In general, if the voltage to the coil is
correct, sluggish valve operation, excessive noise or leakage will indicate that a cleaning is
required or that the solenoid valve should be replaced.
Regulators:
• Keep the supply air flowing through the regulators as free from dirt and foreign material as
possible. Check supply air pressure weekly.
• When any of the following symptoms occur, it may be necessary to clean the regulators,
replace or install the proper rebuild kit.
a. Excessive relief venting.
b. Inability to attain high secondary pressure.
c. Erratic secondary pressures.
d. Excessive hysteresis (a retardation of desire effect: in this case because of the lack
of lubrication.)
e. Leakage of any type.
Exterior cleaning:
If it should become necessary to clean this equipment, disconnect the unit from all power
sources first. Do not use liquid cleaners, aerosols, abrasive pads, scouring powders or solvents,
such as benzine or alcohol. Use a soft cloth lightly moistened with a mild detergent solution.
Ensure the surface cleaned is fully dry before reconnecting power.
Original Instructions
Section 5.3
Recommended Spare Parts List Air Control Module
Series 446
NOTE: Due to long lead times and part availability, the above parts may not be in Dynamic Air's stock.
Section numbers listed above are for standard material lists only. Any custom material lists appear-
ing in the Non-Standard section (Section 10.1) should be referenced in place of standard material
lists of identical nature listed above.
Original Instructions
Section 6.1
1/4" FASTENERS
COVER PLATE
CLAMP HALVES
Original Instructions
PIPE NIPPLE CLAMP BLANK
PIPE REDUCER
DYNAMIC AIR PIPE NIPPLE
SECTION A-A
TRADEMARK LABEL VIEW ROTATED 90˚
REGULATOR EQUIPMENT ID
FOR CLARITY
LABEL
SOLENOID GAUGE
LOCKOUT ENERGY
MALE TUBING CONNECTOR
SOURCES LABEL
MUFFLER A ELBOW
TUBING
PANEL
ELBOW
FLOW
A
FLOW ARROW LABEL
PIPE NIPPLE
Section 7.1
PIPE NIPPLE
1-1/4" NPT B
1-1/4" NPT
FLOW OUT FLOW IN
ACM 125-1 Assembly, NEMA 4
1/4" FASTENERS
B
COVER PLATE
GAUGE & BUSHING ELBOW
REGULATOR
CLAMP HALVES
CLAMP BLANK
Series 446
SECTION B-B
VIEW ROTATED 90˚
Air Control Module
FOR CLARITY
TM172-3
1/4" FASTENERS
Original Instructions
PIPE TEE CLAMP HALVES
PIPE NIPPLE
PIPE NIPPLE
REGULATOR REGULATOR CLAMP BLANK
GAUGE GAUGE
ELBOW
SECTION A-A
ELBOW
A VIEW ROTATED 90˚
MALE TUBING CONNECTOR REGL-1 REGL-2 SOLENOID FOR CLARITY
SOLENOID
MALE TUBING ELBOW
FLOW FLOW
CONNECTOR A
MALE TUBING
#8 FASTENERS CONNECTOR
SV-1 SV-2
MUFFLER ELBOW
TUBING EQUIPMENT ID LABEL
PANEL LOCKOUT ENERGY
SOURCES LABEL
PIPE NIPPLE PIPE NIPPLE
1-1/4" NPT B 1-1/4" NPT
Section 7.2
FLOW OUT FLOW IN
(TO TRANSPORTER) (FROM AIR SUPPLY)
ACM 125-2 Assembly, NEMA 4
1/4" FASTENERS
GAUGE & BUSHING ELBOW COVER PLATE
REGULATOR
CLAMP HALVES
CLAMP BLANK
Series 446
SECTION B-B
Air Control Module
TM172-4
DYNAMIC AIR EQUIPMENT ID
TRADEMARK LABEL MUFFLER LABEL
Original Instructions
CONTROLLER PIPE TEE
A
EXH
PIPE NIPPLE
MALE TUBING OUT
CONNECTOR
A
ELBOW IN
ELBOW
PANEL GAUGE
SECTION A-A
TUBING
PIPE NIPPLE B PIPE NIPPLE
FLOW OUT FLOW IN
(TO TRANSPORTER) (FROM AIR SUPPLY)
Section 7.3
GAUGE & BUSHING 1/4" FASTENERS
ELBOW
REGULATOR COVER PLATE
ACM 125-M Assembly, NEMA 4
CLAMP HALVES
PRESSURE CONTROL CARD WIRING CLAMP BLANK
JUMPER SUPPLY 24 VDC
SUPPLY 24 VDC (75)
V+ RED AT 150-300 mA
V+ RED
RED AT 150-300 mA RED
GND GND GRN SUPPLY COMMON
SIGNAL COMMON (74) GRN SECTION B-B
CMD- BLK CMD- SIGNAL COMMON
BLK BLK BLK
CMD+ 0-10 VDC SIGNAL (73) CMD+ VIEW ROTATED 90˚
WHT WHT WHT 4-20 mA SIGNAL
LMS2 LMS2 FOR CLARITY
WHT
LMS1 LMS1
SHIELD SHIELD
PRESSURE CONTROL PRESSURE CONTROL
Series 446
TM172-5
1/4" FASTENERS
COVER PLATE
CLAMP HALVES
Original Instructions
CLAMP BLANK
SECTION A-A
PIPE NIPPLE VIEW ROTATED 90˚
PIPE REDUCER FOR CLARITY
DYNAMIC AIR
TRADEMARK LABEL PIPE NIPPLE EQUIPMENT ID
REGULATOR LABEL
LOCKOUT ENERGY
SOLENOID
SOURCES LABEL
MALE TUBING
CONNECTOR GAUGE
A ELBOW
MUFFLER
ELBOW
TUBING
FLOW
PANEL A
FLOW ARROW LABEL
PIPE NIPPLE PIPE NIPPLE
B
2" NPT 2" NPT
Section 7.4
FLOW OUT FLOW IN
(TO TRANSPORTER) (FROM AIR SUPPLY)
ACM 200-1 Assembly, NEMA 4
B
GAUGE & BUSHING 1/2" FASTENERS
ELBOW
REGULATOR COVER PLATE
CLAMP HALVES
CLAMP BLANK
Series 446
SECTION B-B
Air Control Module
TM172-6
1/4" FASTENERS
COVER PLATE
Original Instructions
TRADEMARK LABEL PIPE TEE
CLAMP BLANK
PIPE NIPPLE PIPE NIPPLE
REGULATOR REGULATOR
GAUGE GAUGE SECTION A-A
ELBOW VIEW ROTATED 90˚
FOR CLARITY
ELBOW
A REGL-2
MALE TUBING CONNECTOR REGL-1
SOLENOID
SOLENOID
MALE TUBING ELBOW
FLOW FLOW A
CONNECTOR
MALE TUBING
#8 FASTENERS CONNECTOR
SV-1 SV-2
MUFFLER
ELBOW
TUBING
EQUIPMENT ID LABEL
PANEL
PIPE NIPPLE
LOCKOUT ENERGY
2" NPT B
SOURCES LABEL
Section 7.5
(FROM AIR SUPPLY)
ACM 200-2 Assembly, NEMA 4
2" NPT
B
PIPE NIPPLE
GAUGE & BUSHING ELBOW
1/2" FASTENERS
REGULATOR COVER PLATE
CLAMP HALVES
CLAMP BLANK
SECTION B-B
Series 446
TM172-7
DYNAMIC AIR EQUIPMENT ID PIPE NIPPLE
TRADEMARK LABEL LABEL PIPE TEE
MUFFLER
LOCKOUT ENERGY
SOURCES LABEL
#10 FASTENERS
Original Instructions
CONTROLLER
A
MALE TUBING EXH
CONNECTOR OUT
SECTION A-A
A
ELBOW
IN
ELBOW
PANEL
PIPE NIPPLE GAUGE PIPE NIPPLE
2" NPT B
TUBING 2" NPT
FLOW OUT FLOW IN
(TO TRANSPORTER) (FROM AIR SUPPLY)
Section 7.6
COVER PLATE
CLAMP HALVES
ACM 200-M Assembly, NEMA 4
CLAMP BLANK
PRESSURE CONTROL CARD WIRING
SUPPLY 24 VDC
SUPPLY 24 VDC (75) RED AT 150-300 mA SECTION B-B
AT 150-300 mA V+
V+ RED RED RED VIEW ROTATED 90˚
GND GND GRN SUPPLY COMMON FOR CLARITY
SIGNAL COMMON (74) GRN
CMD- BLK CMD-
JUMPER BLK BLK BLK SIGNAL COMMON
CMD+ 0-10 VDC SIGNAL (73) CMD+
WHT WHT WHT
LMS2 LMS2 WHT
4-20 mA SIGNAL
LMS1 LMS1
SHIELD SHIELD
PRESSURE CONTROL PRESSURE CONTROL
CARD TERMINALS CARD TERMINALS
Series 446
TM172-8
1/4" FASTENERS
COVER PLATE
CLAMP HALVES
Original Instructions
CLAMP BLANK
DYNAMIC AIR AIR IN A
TRADEMARK LABEL AIR OUT SECTION B-B
EQUIPMENT ID
VIEW ROTATED 90˚
LABEL FOR CLARITY
Section 7.7
ASSEMBLY FLOW
ACM 300-1 thru 700-1 Assembly, NEMA 4
FLOW
TEE
ELBOW
Series 446
SECTION A-A
Air Control Module
TM172-9
1/4" FASTENERS
COVER PLATE
CLAMP HALVES
Original Instructions
PIPE NIPPLE CLAMP BLANK
REGULATOR AIR IN AIR OUT
PIPE TEE A SECTION B-B
DYNAMIC AIR PIPE NIPPLE REGULATOR
VIEW ROTATED 90˚
TRADEMARK LABEL FOR CLARITY
GAUGE
GAUGE
EQUIPMENT ID LABEL
ELBOW B ELBOW
MUFFLER TUBING
SOLENOID SOLENOID
MALE TUBING FLOW FLOW
B ELBOW
CONNECTOR
LOCKOUT ENERGY
#8 FASTENERS SOURCES LABEL
MALE TUBING
CONNECTOR
MALE TUBING
CONNECTOR PIPE NIPPLE
BUSHING PIPE ELBOW
GAUGE
FLOW ARROW
LABEL
Section 7.8
FLOW
MECHANICAL
ASSEMBLY
ACM 300-2 thru 700-2 Assembly, NEMA 4
TEE FLOW
ELBOW
Series 446
SECTION A-A
Air Control Module
TM172-10
AIR IN AIR OUT
#10 FASTENERS A PIPE NIPPLE
PIPE TEE
DYNAMIC AIR
TRADEMARK LABEL EQUIPMENT ID LABEL
MUFFLER
Original Instructions
CONTROLLER GAUGE
MALE TUBING ELBOW
CONNECTOR B
CONNECTOR GAUGE
BUSHING PIPE ELBOW
FLOW ARROW LABEL
FLOW
MECHANICAL
ASSEMBLY
FLOW
TEE
Section 7.9
ELBOW
A SECTION A-A
ACM 300-M thru 700-M Assembly, NEMA 4
TM172-11
ACM 125 & 200 Dimensional Drawing Air Control Module
Series 446
FLOW
F F
C
1.00 (25) 14.75 (375), TYP(4)
E A
MODEL A B C D E F APPROX. WT
ACM 125 20.89 (531) 2.44 (62) 3.22 (82) 3.27 (83) 6.22 (158) 1-1/4" NPT 20 LBS (9 KG)
ACM 200 30.79 (782) 7.39 (188) 3.25 (83) 3.00 (76) 6.42 (163) 2" NPT 30 LBS (14 KG)
22.00 (559)
FLOW
A
FLOW
FLOW
A SECTION A-A
8.00 (203)
6.00 (152)
.56 (14)
The following is a typical bill of material of all items which are provided by Dynamic Air. The bubble
numbers shown on this printout relate to bubble numbers which will appear on its corresponding
engineering drawing. Only the items shown on this bill of material will be provided by Dynamic Air,
and all other items required for the installation of the Air Control Module must be supplied by the
customer.
BILL OF MATERIAL 4
5 6 7 8 9 10
Original Instructions
Section 7.13
Customer Assistance Air Control Module
Series 446
We highly encourage the use of our service department for a safe and successful application of
the equipment you have purchased and to provide maximum service life.
Should any questions arise with regard to installation and/or operation that is not covered in this
manual, please call Dynamic Air's customer service department for further recommendations or
visit our website at www.dynamicair.com.
US Office
Dynamic Air Inc.
1125 Willow Lake Boulevard
St. Paul, Minnesota 55110-5193
Phone: +1 651 484-2900
Fax: +1 651 484-7015
UK Office
Dynamic Air Ltd.
26 Peverel Drive
Granby
Milton Keynes MK1 1QZ
England
Phone: +44 (0) 1908 622344
Fax: +44 (0) 1908 646633
Original Instructions
Section 8.1
Customer Satisfaction Survey Air Control Module
Series 446
Dynamic Air is interested in feedback from our customers. Please help us serve
you better by going to www.dynamicair.com/customer.html and completing our
Customer Satisfaction Survey or complete the survey below and fax or e-mail it
to us.
1. Are you satisfied with the delivery of your Dynamic Air product? Yes No
2. Are you satisfied with the performance of your Dynamic Air product? Yes No
3. Are you satisfied with the customer service you received? Yes No
Comments:
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
Name: _____________________________________________________________________
Company: __________________________________________________________________
Country:____________________________________________________________________
Would you like someone from Dynamic Air to contact you? Yes No
(If Yes, be sure to include your contact information above.)
Original Instructions
Section 9.1
Non-Standard Section Air Control Module
Series 446
This section contains custom design information which supersedes the standard design. All
drawings and material lists in this section will replace the drawings and material lists of identical
nature previously listed. If this section has no information, all components are standard.
Original Instructions
Section 10.1