Вы находитесь на странице: 1из 6

CURTAIN

WALL

b
no of wetted wetted LEVEL LEVEL
Chainage d cells paramiter area Rs U/S D/S LENGTH Slope n Q b Q/b SCOUR DEPTH

27.033 3.2 1.7 6 39.6 32.64 0.82424 452.973 452.91 16 0.0036875 0.016 108.90124 29.2 3.7294945 3.2225879625
ka = 0.4927797987 24
Density of backfill earth = 20
Density of fback
pcc concrete = 24

Overturning moment

Pressure Force Lever arm Moment


Earth pressure 24.639 30.799 1.05 32.339
Live load surcharge
Total

Passive pressure
50 % effect consider Total

Moment due to vertical load


h b l
vertical load
1 0.55 1.65 1 0.825 0.907524
2 0.75 0.75 1 0.825 0.562524
3 0.75 0.45 1 0.825 0.337524
4 0.75 0.2 1 0.825 0.1524
TOTAL
Moment due to vertical earth fill

h b l volume weight
0.45 0.125 1 0.05625 1.125
1.2 0.15 1 0.18 3.6
1.95 0.45 1 0.8775 17.55
4
0.125 0.2 0.45

0.15 3 0.75
0.45

2 2.5
0.45 0.75
0.75

1 0.55

1.65

moment
0.7487073
0.4640823
0.2784573
0.12573
1.6169769

lever arm
0.825
2.5
2.5
EXIT GRADIENT
H d2 L α ∫ Ge
1 2.5 24 9.6 5.325971 0.055199

Вам также может понравиться