SCHEDULE OF QUANTITY-format

Item.No Description of Items Qty Unit Rate Amount


1 REINFORCED CEMENT CONCRETE
1.1 Centering and shuttering including strutting, propping etc. and
removal of form for all heights :
1.1.1 Suspended floors, roofs, landings, balconies and access platform

1.1.2 Lintels, beams, plinth beams, girders, bressumers and cantilevers

1.1.3 Columns, Pillars, Piers, Abutments, Posts and Struts


1.2 Steel reinforcement for R.C.C. work including straightening,
cutting, bending, placing in position and binding all complete
above plinth level.
1.2.1 Thermo-Mechanically Treated bars of grade Fe-500 D or more.

1.3 Providing and laying in position machine batched and machine


mixed design mix M-25 grade cement concrete for reinforced
cement concrete work, using cement content as per approved
design mix, including pumping of concrete to site of laying but
excluding the cost of centering, shuttering, finishing and
reinforcement, including admixtures in recommended
proportions as per IS: 9103 to accelerate, retard setting of
concrete, improve workability without impairing strength and
durability as per direction of Engineer-in-charge.“(Note :- Cement
content considered in this item is @ 330 kg/cum.“Excess/ less
cement used as per design mix is payable/recoverable
separately).

1.3.1 All works above plinth level upto floor V level


Sub-Total
2 BRICK WORK
2.1 Brick work with common burnt clay F.P.S. (non modular) bricks of
class designation 7.5 in superstructure above plinth level up to
floor V level in all shapes and sizes in :
2.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand)
2.2 Half brick masonry with common burnt clay F.P.S. (non modular)
bricks of class designation 7.5 in superstructure above plinth
level up to floor V level.
2.2.1 Cement mortar 1:4 (1 cement :4 coarse sand)
Sub-Total
3 MARBLE AND GRANITE WORK
3.1 Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms,
vanity counters, window sills, facias and similar locations of
required size, approved shade, colour and texture laid over 20
mm thick base cement mortar 1:4 (1 cement : 4 coarse sand),
joints treated with white cement, mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding and
polishing to edges to give high gloss finish etc. complete at all
levels.

3.1.1 Granite of any colour and shade


3.1.1.1 Area of slab over 0.50 sqm
3.2 Providing edge moulding to 18 mm thick marble stone counters,
Vanities etc., including machine polishing to edge to give high
gloss finish etc. complete as per design approved by Engineer-in-
Charge.

3.2.1 Granite work

Page 1 of 12
Item.No Description of Items Qty Unit Rate Amount
3.3 Extra for providing opening of required size & shape for wash
basin/ kitchen sink in kitchen platform, vanity counter and similar
location in marble/ Granite/ stone work, including necessary
holes for pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete.

Sub-Total
4 WOOD AND P.V.C. WORK
4.1 Providing wood work in frames of doors, windows, clerestory
4.1.1 windows andteak
Second class other frames, wrought framed and fixed in position
wood
with hold fast lugs or with dash fasteners of required dia &
4.2 Providing
length ( and
holdfixing
fast ISI marked
lugs flush fastener
or dash door shutters
shall conforming to
be paid for
IS : 2202 (Part I) decorative type, core of block board
separately).
4.2.1 35 mm thick including ISI marked Stainless Steel butt hinges
construction with frame of 1st class hard wood and well matched with
necessary
teak 3 ply screws
veneering with vertical grains or cross bands and face
4.3 veneers
Extra foron both faces
providing of shutters.
lipping with 2nd class teak wood battens 25
mm minimum depth on all edges of flush door shutters (over all
area of door shutter to be measured).
4.4 Extra for providing vision panel not exceeding 0.1 sqm in all type
of flush doors (cost of glass excluded) (overall area of door
4.4.1 Rectangular
shutter to beormeasured):
square
4.5 Providing and fixing aluminium die cast body tubular type
universal hydraulic door closer (having brand logo with ISI, IS :
3564, embossed on the body, door weight upto 35 kg and door
width upto 700 mm), with necessary accessories and screws etc.
complete.

4.6 Providing and fixing aluminium sliding door bolts, ISI marked
anodised (anodic coating not less than grade AC 10 as per IS :
1868), transparent or dyed to required colour or shade, with nuts
4.6.1 300x16
and screws
mmetc. complete :
4.7 Providing and fixing aluminium tower bolts, ISI marked, anodised
(anodic coating not less than grade AC 10 as per IS : 1868 )
transparent or dyed to required colour or shade, with necessary
screws etc. complete :

4.7.1 250x10 mm
4.7.2 150x10 mm
4.8 Providing and fixing aluminium handles, ISI marked, anodised
4.8.1 (anodic
125 mm coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or shade, with necessary
4.8.2 100 mmetc. complete :
screws
4.9 Providing and fixing aluminium hanging floor door stopper, ISI
marked, anodised (anodic coating not less than grade AC 10 as
per IS : 1868) transparent or dyed to required colour and shade,
with necessary screws etc. complete.

4.9.1 Twin rubber stopper


4.1 Providing & Fixing decorative high pressure laminated sheet of
plain / wood grain in gloss / matt/ suede finish with high density
protective surface layer and reverse side of adhesive bonding
quality conforming to IS : 2046 Type S, including cost of adhesive
of approved quality.

4.10.1 1.0 mm thick


Sub-Total
5 STEEL WORK
5.1 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coat of
approved steel primer using structural steel etc. as required.

5.1.1 In gratings, frames, guard bar, ladder, railings, brackets, gates and
similar works
Sub-Total
6 FLOORING

Page 2 of 12
Item.No Description of Items Qty Unit Rate Amount
6.1 Marble stone flooring with 18 mm thick marble stone, as per
sample of marble approved by Engineer-in-charge, over 20 mm
(average) thick base of cement mortar 1:4 (1 cement : 4 coarse
sand) laid and jointed with grey cement slurry, including rubbing
and polishing complete with :

6.1.1 Makrana white second quality


6.2 Kota stone slab flooring over 20 mm (average) thick base laid
over and jointed with grey cement slurry mixed with pigment to
match the shade of the slab, including rubbing and polishing
complete with base of cement mortar 1 : 4 (1 cement : 4 coarse
sand) :

6.2.1 25 mm thick
6.3 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and
pillars laid on 12 mm (average) thick cement mortar 1:3 (1
cement: 3 coarse sand) and jointed with grey cement slurry
mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.

6.4 Providing and fixing Ist quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours, shades except
burgundy, bottle green, black of any size as approved by
Engineer-in-Charge, in skirting, risers of steps and dados, over 12
mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand)
and jointing with grey cement slurry @ 3.3kg per sqm, including
pointing in white cement mixed with pigment of matching shade
complete.

6.5 Providing and laying vitrified floor tiles in different sizes


(thickness to be specified by the manufacturer) with water
absorption less than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey
cement slurry @ 3.3kg/sqm including grouting the joints with
white cement and matching pigments etc., complete.

6.5.1 Size of Tile 600x600 mm


6.6 Providing and laying Vitrified tiles in different sizes (thickness to
be specified by manufacturer), with water absorption less than
0.08 % and conforming to I.S. 15622, of approved make, in all
colours & shade, in skirting, riser of steps, over 12 mm thick bed
of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with
grey cement slurry @ 3.3kg/sqm including grouting the joint with
white cement & matching pigments etc. complete.

6.6.1 Size of Tile 600x600 mm


Sub-Total
7 ROOFING
7.1 Making khurras 45x45 cm with average minimum thickness of 5
cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1
m x 400 micron, finished with 12 mm cement plaster 1:3 (1
cement : 3 coarse sand) and a coat of neat cement, rounding the
edges and making and finishing the outlet complete.

7.2 Providing and fixing on wall face unplasticised Rigid PVC rain
water pipes conforming to IS : 13592 Type A, including jointing
with seal ring conforming to IS : 5382, leaving 10 mm gap for
thermal expansion, (i) Single socketed pipes.

7.2.1 110 mm diameter

Page 3 of 12
Item.No Description of Items Qty Unit Rate Amount
7.3 Providing and fixing on wall face unplasticised - PVC moulded
fittings/ accessories for unplasticised Rigid PVC rain water pipes
conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal
expansion.

7.3.1 Coupler
7.3.1.1 110 mm
7.3.2 Single pushfit Coupler
7.3.2.1 110 mm
7.3.3 Single tee with door
7.3.3.1 110x110x110 mm
7.3.4 Single tee without door
7.3.4.1 110x110x110 mm
7.3.5 Bend 87.5°
7.3.5.1 110 mm bend
7.3.6 Shoe (Plain)
7.3.6.1 110 mm Shoe
7.4 Providing and fixing unplasticised -PVC pipe clips of approved
design to unplasticised - PVC rain water pipes by means of
50x50x50 mm hard wood plugs, screwed with M.S. screws of
required length, including cutting brick work and fixing in cement
mortar 1:4 (1 cement : 4 coarse sand) and making good the wall
etc. complete.

7.4.1 110 mm
7.5 Providing and fixing tiled false ceiling of specified materials of
size 595x595 mm in true horizontal level, suspended on inter
locking metal grid of hot dipped galvanized steel sections
( galvanized @ 120 grams/ sqm, both side inclusive) consisting of
main "T" runner with suitably spaced joints to get required
length and of size 24x38 mm made from 0.30 mm thick
(minimum) sheet, spaced at 1200 mm center to center and cross
"T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet,
1200 mm long spaced between main "T" at 600 mm center to
center to form a grid of 1200x600 mm and secondary cross "T" of
length 600 mm and size 24x25 mm made of 0.30 mm thick
(minimum) sheet to be interlocked at middle of the 1200x600
mm panel to form grids of 600x600 mm and wall angle of size
24x24x0.3 mm and laying false ceiling tiles of approved texture in
the grid including, required cutting/making, opening for services
like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted
cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm
dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with
galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at
1200 mm center to center along main T, bottom exposed width
of 24 mm of all T-sections shall be pre-painted with polyester
paint, all complete for all heights as per specifications, drawings
and as directed by Engineer-in-charge.

7.5.1 12.5 mm thick square edge PVC Laminated Gypsum Tile of size
595x595 mm, made of Gypsum plasterboard, manufactured from
natural gypsum as per IS 2095 part I and laminated with white
0.16mm thick fire retardant PVC film on the face side and
12micron
Sub-Total metalized polyester on the back side with all edges
sealed with the face side PVC film which goes around and wraps
8 FINISHING
the edges and is bonded to the edges and the back side
8.1 metalized polyester
12 mm cement plasterfilm so :as to make the tile a completely
of mix
sealed unit.
8.1.1 1:6 (1 cement: 6 coarse sand)

Page 4 of 12
Item.No Description of Items Qty Unit Rate Amount
8.2 15 mm cement plaster on rough side of single or half brick wall
finished with a floating coat of neat cement of mix :
8.2.1 1:4 (1 cement: 4 fine sand)
8.3 Distempering with oil bound washable distemper of approved
brand and manufacture to give an even shade :
8.3.1 New work (two or more coats) over and including water
thinnable priming coat with cement primer
8.4 Painting with synthetic enamel paint of approved brand and
manufacture of required colour to give an even shade :
8.4.1 Two or more coats on new work over an under coat of suitable
shade with ordinary paint of approved brand and manufacture
8.5 Forming groove of uniform size in the top layer of washed stone
grit plaster as per approved pattern using wooden battens, nailed
to the under layer, including removal of wooden battens, repair
to the edges of panels and finishing the groove complete as per
specifications and direction of the Engineer-in-charge :

8.5.1 15 mm wide and 15 mm deep groove


8.6 Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the
plastered wall surface to prepare the surface even and smooth
complete.

Sub-Total
9 DISMANTLING & DEMOLISHING
9.1 Demolishing cement concrete manually/ by mechanical means
including disposal of material within 50 metres lead as per
direction of Engineer - in - charge.
9.1.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

9.2 Demolishing brick work manually/ by mechanical means


including stacking of serviceable material and disposal of
unserviceable material within 50 metres lead as per direction of
Engineer-in-charge.

9.2.1 In cement mortar


9.3 Demolishing dry brick pitching in floors, drains etc. including
stacking serviceable material and disposal of unserviceable
material within 50 metres lead :
9.4 Disposal of building rubbish / malba / similar unserviceable,
dismantled or waste materials by mechanical means, including
loading, transporting, unloading to approved municipal dumping
ground or as approved by Engineer-in-charge, beyond 50 m initial
lead, for all leads including all lifts involved.

Sub-Total
10 SANITARY INSTALLATIONS
10.1 Providing and fixing white vitreous china flat back half stall urinal
of size 580x380x350 mm with white PVC automatic flushing
cistern, with fittings, standard size C.P. brass flush pipe, spreaders
with unions and clamps (all in C.P. brass) with waste fitting as per
IS : 2556, C.I. trap with outlet grating and other couplings in C.P.
brass, including painting of fittings and cutting and making good
the walls and floors wherever required :

10.1.1 Range of three half stall urinals with 10 litre P.V.C. automatic
flushing cistern
10.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P.
brass pillar taps, 32 mm C.P. brass waste of standard pattern,
including painting of fittings and brackets, cutting and making
good the walls wherever require:

Page 5 of 12
Item.No Description of Items Qty Unit Rate Amount
10.2.1 White Vitreous China Wash basin size 630x450 mm with a pair of
15 mm C.P. brass pillar taps
10.3 Providing and fixing white vitreous china laboratory sink with C.I.
brackets, C.P. brass chain with rubber plug, 40 mm C.P brass
waste and 40mm C.P. brass trap with necessary C.P. brass unions
complete, including painting of fittings and brackets, cutting and
making good the wall wherever required :

10.3.1 Size 600x450x200 mm


10.4 Providing and fixing mirror of superior glass (of approved quality)
and of required shape and size with plastic moulded frame of
approved make and shade with 6 mm thick hard board backing :

10.4.1 Rectangular shape 1500x450 mm


10.5 Providing and fixing toilet paper holder :
10.5.1 C.P. brass
10.6 Providing and fixing soil, waste and vent pipes :
10.6.1 100 mm dia
10.6.1.1 Sand cast iron S&S pipe as per IS: 1729
10.6.2 75 mm diameter :
10.6.2.1 Sand cast iron S&S pipe as per IS: 1729
10.7 Providing and fixing M.S. holder-bat clamps of approved design
to Sand Cast iron/cast iron (spun) pipe embedded in and
including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size), including cost of cutting holes and making good
the walls etc. :

10.7.1 For 100 mm dia pipe


10.7.2 For 75 mm dia pipe
10.8 Providing and fixing bend of required degree with access door,
insertion rubber washer 3 mm thick, bolts and nuts complete.

10.8.1 100 mm dia


10.8.1.1 Sand cast iron S&S as per IS - 1729
10.8.2 75 mm dia
10.8.2.1 Sand cast iron S&S as per IS - 1729
10.9 Providing and fixing plain bend of required degree.
10.9.1 100 mm dia
10.9.1.1 Sand cast iron S&S as per IS - 1729
10.9.2 75 mm dia
10.9.2.1 Sand cast iron S&S as per IS -1729
10.1 Providing and fixing double equal junction of required degree
with access door, insertion rubber washer 3 mm thick, bolts and
nuts complete :
10.10.1 100x100x100x100 mm
10.10.1.1 Sand cast iron S&S as per IS - 1729
10.10.2 75x75x75x75 mm
10.10.2.1 Sand cast iron S&S as per IS - 1729
10.11 Providing and fixing collar :
10.11.1 100 mm
10.11.1.1 Sand cast iron S&S as per IS - 1729
10.11.2 75 mm
10.11.2.1 Sand cast iron S&S as per IS - 1729
10.12 Providing lead caulked joints to sand cast iron/centrifugally cast
(spun) iron pipes and fittings of diameter :

10.12.1 100 mm

Page 6 of 12
Item.No Description of Items Qty Unit Rate Amount
10.12.2 75 mm
10.13 Providing and fixing trap of self cleansing design with screwed
down or hinged grating with or without vent arm complete,
including cost of cutting and making good the walls and floors :

10.13.1 100 mm inlet and 100 mm outlet


10.13.1.1 Sand Cast Iron S&S as per IS: 1729
10.13.2 100 mm inlet and 75 mm outlet
10.13.2.1 Sand Cast Iron S&S as per IS- 1729
10.14 Providing and fixing PTMT Bottle Trap for Wash basin and sink.
10.14.1 Bottle trap 31mm single piece moulded with height of 270 mm,
effective length of tail pipe 260 mm from the centre of the waste
coupling, 77 mm breadth with 25 mm minimum water seal,
weighing not less than 260 gms

10.15 Providing and fixing PTMT liquid soap container 109 mm wide,
125 mm high and 112 mm distance from wall of standard shape
with bracket of the same materials with snap fittings of approved
quality and colour, weighing not less than 105 gms.

10.16 Providing and fixing PTMT towel rail complete with brackets fixed
to wooden cleats with CP brass screws with concealed fittings
arrangement of approved quality and colour.

10.16.1 600 mm long towel rail with total length of 645 mm, width 78
mm and effective height of 88 mm, weighing not less than 190
gms.
Sub-Total
11 WATER SUPPLY
11.1 Providing and fixing G.I. pipes complete with G.I. fittings and
clamps, i/c cutting and making good the walls etc. INTERNAL
WORK - EXPOSED ON WALL
11.1.1 15 mm dia nominal bore
11.1.2 20 mm dia nominal bore
11.1.3 32 mm dia nominal bore
11.2 Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end) :
11.2.1 25 mm nominal bore
11.2.2 20 mm nominal bore
Sub-Total
12 ALUMINIUM WORK
12.1 Providing and fixing aluminium work for doors, windows,
ventilators and partitions with extruded built up standard tubular
sections/ appropriate Z sections and other sections of approved
make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required
EPDM rubber/ neoprene gasket etc. Aluminium sections shall be
smooth, rust free, straight, mitred and jointed mechanically
wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws,
all complete as per architectural drawings and the directions of
Engineer-in-charge. (Glazing, paneling and dash fasteners to be
paid for separately) :

12.1.1 For fixed portion


12.1.1.1 Anodised aluminium (anodised transparent or dyed to required
shade according to IS: 1868, Minimum anodic coating of grade
AC 15)

Page 7 of 12
Item.No Description of Items Qty Unit Rate Amount
12.1.2 For shutters of doors, windows & ventilators including providing
and fixing hinges/ pivots and making provision for fixing of
fittings wherever required including the cost of EPDM rubber /
neoprene gasket required (Fittings shall be paid for separately)

12.1.2.1 Anodised aluminium (anodised transparent or dyed to required


shade according to IS: 1868, Minimum anodic coating of grade
AC 15)
12.2 Providing and fixing glazing in aluminium door, window,
ventilator shutters and partitions etc. with EPDM rubber /
neoprene gasket etc. complete as per the architectural drawings
and the directions of Engineer-in-charge . (Cost of aluminium
snap beading shall be paid in basic item):

12.2.1 With float glass panes of 5.50 mm thickness


Sub-Total
13 WATER PROOFING
13.1 Providing and laying water proofing treatment in sunken portion
of WCs, bathroom etc., by applying cement slurry mixed with
water proofing cement compound consisting of applying : (a)
First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be
allowed to air cure for 4 hours. (b) Second layer of slurry of
cement @ 0.242 kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be allowed to air cure
for 4 hours followed with water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry with polymer
mixed slurry.

Page 8 of 12
Item.No Description of Items Qty Unit Rate Amount
13.2 Providing and laying integral cement based water proofing
treatment including preparation of surface as required for
treatment of roofs, balconies, terraces etc consisting of following
operations: (a) Applying a slurry coat of neat cement using 2.75
kg/sqm of cement admixed with water proofing compound
conforming to IS. 2645 and approved by Engineer-in-charge over
the RCC slab including adjoining walls upto 300 mm height
including cleaning the surface before treatment. (b) Laying brick
bats with mortar using broken bricks/brick bats 25 mm to 115
mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse
sand) admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge over 20 mm thick layer
of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed
with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating
similarly the adjoining walls upto 300 mm height including
rounding of junctions of walls and slabs. (c) After two days of
proper curing applying a second coat of cement slurry using 2.75
kg/ sqm of cement admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer- in-charge. (d)
Finishing the surface with 20 mm thick jointless cement mortar
of mix 1:4 (1 cement :4 coarse sand) admixed with water
proofing compound conforming to IS : 2645 and approved by
Engineer- in-charge including laying glass fibre cloth of approved
quality in top layer of plaster and finally finishing the surface with
trowel with neat cement slurry and making pattern of 300x300
mm square 3 mm deep. (e) The whole terrace so finished shall
be flooded with water for a minimum period of two weeks for
curing and for final test. All above operations to be done in order
and as directed and specified by the Engineer-in-Charge :

13.2.1 With average thickness of 120 mm and minimum thickness at


khurra as 65 mm.
Sub-Total
14 NEW TECHNOLOGIES AND MATERIALS
14.1 Chipping of unsound/weak concrete material from slabs, beams,
columns etc. with manual Chisel and/ or by standard power
driven percussion type or of approved make including tapering
of all edges, making square shoulders of cavities including
cleaning the exposed concrete surface and reinforcement with
wire brushes etc. and disposal of debris for all lead and lifts all
complete as per direction of Engineer-In-Charge

14.1.1 50mm average thickness


14.2 Cleaning of reinforcement from rust from the reinforcing bars to
give it a total rust free steel surface by using alkaline chemical
rust remover of approved make with paint brush and removing
loose particles after 24 hours of its application with wire brush
and thoroughly washing with water and allowing it to dry, all
complete as per direction of Engineer-In-Charge.

14.2.1 Bars above 12 mm diameter

Page 9 of 12
Item.No Description of Items Qty Unit Rate Amount
14.3 Drilling suitable holes in reinforced or plain cement concrete with
power driven drill machine to a minimum depth of 100mm upto
200mm in RCC beams, lintels, columns and slabs to introduce
steel bars for sunshades/balconies including fixing the steel bars
in position using epoxy resin anchor grout of approved make but
excluding the cost of reinforcement, all complete as per direction
of Engineer-In- Charge.

14.3.1 Upto and including 12mm dia.


14.4 Providing, mixing and applying bonding coat of approved
adhesive on chipped portion of RCC as per specifications and
direction of Engineer-In-charge complete in all respect.
14.4.1 SBR Polymer (@10% of cement weight) modified cementitious
bond coat @2.2 kg cement per sqm of surface area mixed with
specified proportion of approved polymer
14.5 Providing and inserting 12mm dia galvanised steel injection
nipple in honey comb area and along crack line including drilling
of holes of required diametre (20mm to 30mm) up to depth from
30mm to 80mm at required spacing and making the hole & crack
dust free by blowing compressed air, sealing the distance
between injection nipple with adhesive chemical of approved
make and allow it to cure complete as per direction of Engineer-
In-Charge.

Sub-Total
15 MINOR CIVIL MAINTENANCE WORK
15.1 Wall hanging cumboard with seat cove etc
15.2 providing and fixing plain plywood 19mm good quality for
making wooden furniture of rack & shelves with brass screw
whenever requered including wooden beading at the edges of
ply etc complete.

15.3 "Supplying and fixing Double skin insulated roofing system


comprising of Tracdeck Hi-Rib profiled external sheets
manufactured out of 0.5 mm TCT SMP coated Galvalume steel
(150 GSM Zinc aluminum alloy coating mass total of both
sides,AZ-150 as per as 1397) having 550 Mpa yield strength . The
sheets shall have 1000-1020 mm cover width, 28-30mm high
crests at 200-250 mm wide pan with special male / female using
3 small ribs. The inner sheet shall be 0.5 mm Hi-Rib SMP Coated
Galvalume hi-tensile steel in similar dimensions / size and fixed
to the structure (by others) by means of corrosion protected self
drilling , self tapping fasteners. The sub –grits of size 50mm x
50mm x 50mm manufactured out of 1.6mm G.I. ‘Z’ Shape would
be fixed to inner sheeting face side at purlin locations by means
of galvanized polymer coated self drilling , self tapping fasteners
thru the crest. The outer sheeting shall be fixed glass wool
insulation of (24 kg-density) wrapped in black polthene shall be
fixed in the cavity between two sheets. The sheets shall be
supplied in custom lengths.
"

15.4 Supplying and fixing flashing / capping etc. of trackdeck HI-Rib


profiled external sheets manufactured out of 0.50 mm TCT SMP
coated Galvalume steel (150 GSM Zinc aluminum alloy coating
mass total of both sides,AZ-150 as per as 1397) having 550 Mpa
yield strength. This shall be fixed by means of self- drilling, self-
stitching screws (12-14x20) with EPDM nylon washer.
"

Page 10 of 12
Item.No Description of Items Qty Unit Rate Amount
15.5 P/f Double Glazed dual sealed insulating glass to aluminium
frame with norton tape, silicon stuctural sealant and weather
proofing using weather proofing sealant (Dowcorning / wacker or
equivalent) Silicon joint visible from out side. The insulated glass
comprising of first 6mm thick Olive Nano SKN 154 (external)
toughened (Saint-gobain or equivalent) wtih the solar control
and Low E coating on face 2, second 5mm thick clear float glass
(internal) toughened (Saint Gobain or equivalen), ( meeting the
minimum glass specification mentioned below) separated by
spacers to create 10mm dehydrated air space and thermatically
sealed by using double sealed organic sealant (priming sealant of
thermoplastic), solvent free polyisobutylene which is applied on
both sides of spacer, secondary sealant compreising of two
component polysulphide in the right proportin for final outer
seal incl. perforated shannel for air spaces and complete
processed with expertise of manufacturing insulated glass
(Gurind / Art N glass / Gold plus).
1) Light Transmission - 49% 2) Reflection (Ext)-18% 3) Solar Factor
- 0.27 4) U value - 1.8 W/sqm K. (The aluminium frame shall be
paid separately in relevant item)

15.6 Providing and fixing G.I sheet of 24 guage size 0.75m x 3.00m
alround construction area with vertical balies @ 2.5m c/c and
three number horizontal ballies of 75mm to 100mm dia height
upto 3.00m incl. bracing of ballies at every 10m Removal of
above material after due dismantling and takinig back the
material from the work site after completion of the work

15.7 Providing and fixing dash fstners of size 12mm x 100mm for
failing of stairs, corridors and parapet i/c driling fixing and
necessary welding etc complete.
15.8 Centering and shuttering i/c strutting, propping etc. and removal
of form work for mullions upto floor five levels etc complete.

15.9 P/f Silicon sealent (GE, DOW CORNIING or equivalent) to


expansion joint including providing & fixing backer rod &
maskeing tap as per the manufacturer's specification or as
directed by the Enginer-in-charge complete (upto 50mm wide &
12mm deep)

15.1 P/f in Expansion joint Expanded polyethylene of density 28 to


32kg/cum like Armour board or Equivalent approved make of
desired thickness (required thickness to me make up at source
using minimum 10mm thick sheet ) using adhesive or double
sided adhesive tampe to the coasted surface to form the
expansion joint of required width. This item shall included
preparatin of surface by cleaning of dust oil loose agregate etc.
Espansion joint 50mm thick

15.11 Provding and fixing bonding coat (Nito bond or equivalent) on


concrete surface at all levels.

Page 11 of 12
Item.No Description of Items Qty Unit Rate Amount
15.12 P/f in positin in wall lining, dado as bands at all levels and height
on all masonry and concrete elements and such other locations
as called for unglazed, homogeneous, silicon dipped, Unicera
vitrified wall cladding clay tiles of size 230x75x15mm or approved
equivalent make in terracotta colour incl. scaffolding, curing etc
compete as per specification details below:
P/a bonding coat (Nitobond or equivalent) on concrete surface.
P/a 12mm thick base plaster of mix 1:4 (i cemnt : 4 coarse sand)
mixed with approved integral water profing compound like sika
plastocrete - super or pidiproof LW or equivalant in the
propotins recommended by the manufacturer and furrowed with
scratching tool.
P/a 10mm thick top layer of plaster in the proportion of 1cemnt :
2coarse sand: 2 fine sand (mixed with approved integral water-
proofing compound like sika plastocete-super or pidiproof LW or
equivalent in the proportions recommended by the completely
filling thick cement paste on the tile negative grooves.
Fixinig tiles in to the wet cement plaster by ensuring straight
lines, ruled pointing with cement mortar 1:3

Sub-Total
Total

Page 12 of 12