Вы находитесь на странице: 1из 37

STE-D

Digital Power Line Carrier


STE-D
Overview

STE-D is a terminal equipment for


power lines data transmission.

STE-D with optional Multiplexer


function can transmit different voice
and data channels on power lines. The
equipment can manage different types
of user interfaces, multiplexing voice
and data tributary channels in the
aggregate stream.

STE-D with optional Drop-Insert


function works as a network node in
TDM networks.

STE-D with optional Router function


works as a network node in IP
networks.
STE-D
Key features (1)

¾ Frequency range: 40 – 500 kHz (40 – 1000 kHz STE-DE version)

¾ Channel frequency: programmable 1 kHz step

¾ Baud rate: 64 / 32 / 16 kbit/s

¾ Channel bandwidth: 16 / 8 / 4 kHz [with Echo Canceller]

¾ Modulation type: 64-TCM (Trellis Code Modulation)

¾ Peak Envelope Power: 10 / 20 / 40 W


STE-D
Key features (2)

¾ Full coexistence with analogue PLC transmission systems

¾ Totally compliant with International Recommendation IEC 495

¾ Management of the connection quality ITU-T G.821

¾ Alarm historical log in non-volatile memory

¾ Integrated Sub-Multiplexer and Drop-Insert function

¾ Integrated Router function

¾ Configuration and monitoring of remote equipment through EOC


STE-D
User interfaces

¾ ITU-T G.703 -- 64 kbit/s

¾ ITU-T X.21 / V.11 -- 64 / 32 / 16 kbit/s

¾ Ethernet 10BaseT

¾ ITU–T V.24 / EIA TIA RS232 -- 1,2–19,2 kbit/s

¾ Speech 2/4W + E&M (ITU-T G.729 compression)

¾ Speech FXO / FXS (ITU-T G.729 compression)

¾ Speech 300 - 3400 Hz for FSK channels (ADPCM coded)


STE-D
Performance (1)

¾ Min. SNR value 16 kHz Tx + Rx bandwidth 25 dB at 64 kbit/s

17 dB at 32 kbit/s

9 dB at 16 kbit/s

8 kHz Tx + Rx bandwidth 25 dB at 32 kbit/s

17 dB at 16 kbit/s

4 kHz Tx + Rx bandwidth 25 dB at 16 kbit/s

¾ Crossing delay: ≤ 60 ms

¾ Bit Error Rate: ≤ 10-7 (64 kbit/s / SNR = 25 dB)


STE-D
Performance (2)

¾ Nominal envelop level PEP = 40W / + 46 dBm + 35 dBm in standard mode

+ 39 dBm in enhanced mode

PEP = 20W / + 43 dBm + 32 dBm in standard mode

+ 36 dBm in enhanced mode

PEP = 10W / + 40 dBm + 29 dBm in standard mode

+ 33 dBm in enhanced mode


STE-D
Performance – Noise vs. Attenuation for STED 40 W / 64 kbit/s version

Power Line Noise (dBm)

+5 Enhanced mode
Standard mode
+0

-5

- 10

- 15

- 20

- 25

- 30

- 35

Line Attenuation (dB)


5 10 15 20 25 30 35 40 45
STE-D
Performance – Power Budget calculation for STED 40 W / 64 kbit/s version

Rx Minimum
Power Corona Echo Power Line
Line Noise (*) canceller Total noise -S/N 25 dB Attenuation Line Length
Voltage noise -BER = 10-7 (**)
[Kv] [dBm] [dBm] [dBm] [dBm] [dB] [km]

With Echo
Canceller 132 - 27 - 23 - 21,5 + 3,5 31,5 315

Without
Echo 132 - 27 -- - 27 -2 37 370
Canceller
With Echo
Canceller 380 - 17 - 23 - 16 +9 26 371

Without
Echo 380 - 17 -- - 17 +8 27 385
Canceller

(*) Noise in 16 KHz bandwidth (IEC 663)


(**) Average Line Attenuation 0,1 dB / 132 kV, 0,07 dB / 380 kV (IEC 663)
STE-D
Architecture

Network Remote
management Terminal
system V.28
Ethernet 10 BT

Aggregate
64 kbit/s
streams
section (PAU) Power

/s
Kbit/s
Amplifier Unit

Bus 64/56 Kbit


Control Digital Tx Filter Rx Filter
Ethernet LINE HF
10BaseT Management Processing (TXF) (RXF)
Unit (CMU) Unit (PAU) Power
(DPU) Amplifier Unit

Speech Tributary
Tributary
Tributary
Units 1÷4
Data Tributary
Unit
(SIU/DIU)
Unit
FSK Unit TPU
Teleprotection
Unit
STED block diagram

SELTA TPS-NU
Main units Teleprotection

Optional SUB-MULTIPLEXER units

Optional TELEPROTECTION interface

External rack
STE-D
Sub-multiplexer section
64 kbit/s ITU–T X.50 framing architecture = 20 payload envelope
60 kbit/s 4 kbit/s

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FRAME ALLIGN.

2,4 kbit/s DATA channel = (1)

4,8 kbit/s DATA channel = (2)

9,6 kbit/s DATA channel = (4)

19,2 kbit/s DATA channel = (8)

SPEECH channel (G.729 + sign.) = (3)

FSK SPEECH channel = ---- (20)


STE-D
Main Units: DIGITAL PROCESSING UNIT
STE-D
Main Units: DIGITAL PROCESSING UNIT

The Digital Processing Unit (DPU) is divided in three main functional blocks:
· High Frequency
· Base Band
· Alignment
High Frequency section covers the modulator and demodulator, and the scrambler and
descrambler functions and provides channelling.
Base Band section carries out:
· in transmission: Trellis coding (64 TCM) and data flow composition
· in reception: 64 TCM decoding and equalizing
Alignment section constitutes the interface to the 64kb/s data bus:
· transmission and receipt overhead management
· X.50 frame alignment
The functions of each section are developed by a DSP.
STE-D
Main Units: CONTROL MANAGEMENT UNIT
STE-D
Main Units: CONTROL MANAGEMENT UNIT

CMU
Agent SNMP
Router IP CMU
Sync EXT, Alarms
Framer X.50 BUS 64 Kbit/s
G703 / V11
Framer X.50 Framer X.50

ITU-T G.703 / V.11 Voice &


Low rate
DIU FSK SIU
Data channels
Ethernet 10BaseT channels

5 x V.24 / V.28 2 x 2/4 W + E/M

Basic unit

Interface units (max. 4 slot available)


STE-D
Main Units: TX FILTER
STE-D
Main Units: TX FILTER

• The transmission filter receives the signal from the amplifier (in case of two amplifies a sum
circuit is activated).

• The bandwidth can be set at steps of 4kHz from 40 to 500 kHz using jumpers.
STE-D
Main Units: RX FILTER
STE-D
Main Units: RX FILTER

• The RX filter profiles the signal in order to eliminate adjacent bands.

• The working band of 16kHz is set by steps of 4kHz from 40 to 500kHz by using jumpers.
STE-D
Main Units: POWER AMPLIFIER
STE-D
Main Units: POWER AMPLIFIER

• The Power Amplifier Unit (PAU) receives signals from the Digital Processing Unit in the
40 ÷ 500 kHz band, and amplifies them by means of an initial differential stage, followed
by two drivers and a final push-pull stage, thus obtaining linear amplification of 29dB
across the band.

• Each power unit can supply up to 20W of continuous HF power.


STE-D
Main Units: POWER SUPPLY
STE-D
Main Units: POWER SUPPLY

• The Power Supply (PSU) consists of a single Height Dependability unit, available in two
versions:

85 W 24 ÷ 48 V / +5 V, –5 V, -30 V converter

150 W 48 V / +5 V, –5 V, -30 V converter

which can be used according to the equipment power class.


STE-D
Optional Units: SPEECH INTERFACE UNIT
STE-D
Optional Units: SPEECH INTERFACE UNIT

E / M signal

Speech channel A Compressor Framer

Bus 64 Kbit/s
FXO / FXS
D G.729 X.50

300 – 3400 Hz (analog) 64.000 bit/s (digital)

300 – 3400 Hz (analog) 8.000 bit/s (digital)


+ E / M signal

9.000 bit/s (digital)


num. 3 envelope
STE-D
Optional Units: DATA INTERFACE UNIT
STE-D
Optional Units: DATA INTERFACE UNIT

Interface signalling C105,


105, C108 ...

DATA channel
RS 232 V.14 Framer

Bus 64 Kbit/s
V.28 async-sync adapter X.50

Async/sync sw

1.200 – 19.200 bit/s

X.21 / X.20
sync / async
STE-D
Optional Units: Teleprotection Interface

•Transmission support POF type optical fibre (plastic 1mm)

•Wavelength 650 nm

RX
•Optical transmission power - 7 dBm
TX
•Minimum sensitivity - 20 dBm

•Guaranteed attenuation 12 dB

•Reception overload 0 dBm

•Optical connectors Latching Duplex (Agilent Versatile link family)


IND

RX AL

READY

WD
TPU
STE-D
Service Interfaces

Synchronisation interface
STE-D is provided with a 2048 kHz / ITU-T G.703 synchronisation interface, for clock
signal generated by GPS devices or SDH network.

Management interfaces
The Management interface is Ethernet 10BaseT with RJ 45 type connector.
It also available a ITU-TV.28 management interface dedicated to a Local Element
Manager connection (CT interface).

Alarms interface
The Alarm interface reports the network and the equipment summary alarms, trough
dedicated relays contacts (more details available in General Technical Description
document).
STE-D
Management system

A Management System is available with graphical interface for an easy and intuitive use.

It is realized on a PC platform with Windows 95/98/NT/2000/XP Operating System, and the


following functions:

- Configuration management
- Alarms diagnostic
- Software updating

It is also possible the Management using a non-proprietary Management System since STED
Information Model (MIB) is available in syntax compliant with International IETF SMI.
STE-D
Applications
64Kb/s ITU-T G.703 Unframed -- 64Kb/s or sub-rate ITU-T V.11:
radio link, primary order Multiplexer, external router

MUX
SAFN
Power Line
STE-D G.703

Leased line
G.703

V.11

Router
STE-D
Applications

Voice and Data users:


integrated SMUX (with Drop/Insert function)

Power Line Power Line

STE-D STE-D

G.703

Voice and Data interfaces


STE-D
Applications

IP users:
integrated router (64Kb/s or sub-rate bit rate)

Power Line STE-D

LAN
STE-D
Technical data

¾ HF Interface: Balanced / Unbalanced


¾ HF Nominal impedance : 50, 75 ohm (unbalanced)
124, 150 ohm (balanced)
¾ Power supply voltage range: 48 Vdc + 20% -15%
¾ Power consumption : ≤ 150 Watt
¾ Subrack type : ETSI subrack 16 SU (10+6)
¾ Dimensions: 483 x 400 x 280 mm
¾ Weight: < 14 Kg full equipped
STE-D
Teleprotection performance *

Applications: direct, permissive and blocking command

Transmission time: 10 ms

Reliability: 1e-6

Security: 1e-6

* Compliant with IEC 834-1


STE-D
Teleprotection operations – Analog vs. Digital PLC

ANALOG PLC and ANALOG TELEPROTECTION (SELTA STE-N + TPS-NU)


¾ Interruption speech and data transmission service;
¾ Transmission of PLC pilot signal at the maximum level (PEP);
¾ Cut off PLC pilot signal and transmission of the command signal coming from TPS equipment;
¾ Restore speech and data transmission service.

STE-D DIGITAL PLC (SELTA STE-D + TPS-NU)


¾ Interruption speech and data transmission service;
¾ Freezing adaptive Echo Canceller coefficient;
¾ Transmission of PLC pilot signal at the maximum level (PEP);
¾ Cut off PLC pilot signal and transmission of command signal coming from TPS equipment;
¾ Restore speech and data transmission services.