Академический Документы
Профессиональный Документы
Культура Документы
1
Dept. of Operative Dentistry, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
2
Dentist, Lecturer, School of Dentistry, Shahed University, Tehran, Iran.
Abstract
Objectives: The aim of this study was to compare polymerization depth of two bulk-
fill and one conventional composite cured for different times.
Methods: This in vitro experimental study was conducted on 54 composite samples
(2×4×10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio
conventional composite cured for 20, 30, and 40 seconds. The microhardness of
samples was measured at 0.1, 2, 2.5, 3, 3.5, 4, and 4.5mm depths using a Vickers
hardness tester. The results were analyzed using ANOVA, t-test, and Tukey’s test.
Results: The x-tra fil, Tetric N-Ceram and Grandio had maximum microhardness at
0.1mm depth after curing for 40 seconds. The microhardness decreased as the depth of
composite increased. Microhardness of x-tra fil was higher than that of Tetric N
Ceram. By increasing the curing time, the microhardness value of x-tra fil significantly
increased up to 2mm depth. In Tetric N-Ceram, by increasing the curing time from 20
to 30 seconds microhardness increased significantly (P<0.05) by up to 3.5mm depth.
By increase from 20 to 30 seconds, no significant change occurred in microhardness of
Grandio samples at 0.1 and 2mm depths, but further increase from 30 to 40 seconds
significantly increased the microhardness at all depths (P<0.05).
Conclusion: The maximum microhardness was obtained for x-tra fil at 0.1mm depth
following 40 seconds of curing. Microhardness in deep areas (>2mm depth) depends
on the type of composite, curing time and depth. Overall, 20 seconds of curing for x-
*Corresponding Author: tra fil and 30 seconds for Tetric N-Ceram seem appropriate.
Kalantar Motamedi M. Key Words: Hardness; Polymerization; Composite Resins
E-mail: How to cite:
Mojdehmotamedi@yahoo.com
Jaberi Ansari Z, Ghasemi A, Vatandoust MT, Kalantar Motamedi M. Effect of Curing
Received: 12.10.2016
Time on Polymerization Rate of Bulk-Fill Composite Resins Restorations. J Dent Sch
Accepted: 20.12.2016 2016; 34(4): 214-24.
advantages of these composites resulting in composite samples divided into nine groups
increased depth of polymerization from 1- (n=6) as follows:
1.5mm to 4-5mm (9, 10). Group A1: Bulk-fill composite (x-tra fil;
Type of filler (size and volume), type of Voco, Cuxhaven, Germany) cured for 20
light curing unit, effects of restorative seconds
material on light absorption and method of Group A2: Bulk-fill composite (x-tra fil;
clinical application and equipment i.e. Voco, Cuxhaven, Germany) cured for 30
distance from the light curing tip to the seconds
sample surface, and light curing duration are Group A3: Bulk-fill composite (x-tra fil;
among the main parameters affecting the Voco, Cuxhaven, Germany) cured for 40
light polymerization of composites (11, 12). seconds
On the other hand, the correlation between Group B1: Bulk-fill composite (Tetric N-
the polymerization and hardness has been Ceram; Ivoclar Vivadent AG, Schaan,
discussed in many studies (13,14). Li et al. Liechtenstein) cured for 20 seconds
(13) assessed the correlation of Knoop Group B2: bulk-fill composite (Tetric N-
microhardness and curing depth of RZE04 Ceram; Ivoclar Vivadent AG, Schaan,
experimental composite and reported that Liechtenstein) cured for 30 seconds
the Knoop microhardness decreased along Group B3: bulk-fill composite (Tetric N-
the curing depth. Rode et al. (14) evaluated Ceram; Ivoclar Vivadent AG, Schaan,
the effect of the distance from the curing tip Liechtenstein) cured for 40 seconds
on cure depth of composite resins via Group C1: conventional composite
measuring the Vickers microhardness and (Grandio; Voco, Cuxhaven, Germany) cured
reported that increasing the thickness of for 20 seconds
composite resin decreased the Group C2: conventional composite
microhardness value. (Grandio; Voco, Cuxhaven, Germany) cured
Considering the fact that adequate for 30 seconds
polymerization is a key factor in longevity of Group C3: conventional composite
composite restorations, this study aimed to (Grandio; Voco, Cuxhaven, Germany) cured
assess the effect of curing time on depth of for 40 seconds
polymerization of two bulk-fill composites For sample preparation, the respective
and a conventional composite resin using composite was applied to a brass mold
Vickers hardness test. measuring 2mm in width, 4mm in length
and 10mm in height and a transparent Mylar
Methods strip was placed over it to achieve a smooth
surface at the level of the mold height. The
mold was closed by fixing the screws at the
This study was approved in the Research sides and the composite was light cured
Committee of Shahid Beheshti University, from the exposed surface using an LED light
School of dentistry. This in-vitro, curing unit (L.E. Demetron II, Kerr, CA,
experimental study was conducted on 54 USA) with an intensity of 800 mW/cm2.
Curing Time & Polymerization Rate of Composite Resins 216
Table 1- The mean and standard deviation of Vickers hardness number in all groups
Type of Curing 0.1mm 2mm depth 2.5mm 3mm depth 3.5mm 4mm depth 4.5mm
composite time depth depth depth depth
X-tra fil 20s 103.18±5.37 61.77±2.05 52.18±5.13 46.16±1.70 38.67±2.60 33.56±4.57 18.00±2.42
30s 112.67±5.11 60.52±3.10 53.09±8.88 46.75±2.93 39.41±1.21 32.09±2.75 16.62±1.43
40s 127.55±3.33 71.00±7.05 55.90±5.43 50.93±4.73 43.42±5.18 37.51±2.95 26.22±2.62
Tetric N- 20s 107.04±8.55 41.18±3.42 36.15±1.18 35.58±3.45 30.12±3.47 26.73±2.44 13.44±2.83
Ceram 30s 105.25±3.95 55.30±3 46.64±4.15 45.67±3.69 39.47±4.11 30.24±3.17 15.63±2.56
40s 118.31±9.00 57.53±10.4 51.28±9.48 42.01±2.92 36.32±3.86 31.56±5.47 17.13±2.02
Grandio 20s 99.52±5.54 40.76±3.10 28.50±2.88 12.66±3.28
30s 105.46±4.77 47.86±2.39 36.84±1.49 17.64±3.76
40s 116.69±6.56 56.86±8.23 43.45±4.17 23.41±5.23
-At 2.5 mm depth, the Vickers hardness composites in terms of Vickers hardness
number of x-tra fil was significantly higher number (P=0.15 and P=0.85, respectively);
than that of Tetric N-Ceram and Grandio but the Vickers hardness number in these
(P<0.05). Also, the Vickers hardness composites was higher than that of Grandio
number in Tetric N-Ceram was significantly conventional composite (P<0.05).
higher than that of Grandio (P<0.05). -At 3.5mm depth (P=0.97), at 4mm depth
-At 3mm depth, the Vickers hardness (P=0.30) and at 4.5mm depth (P=0.42), no
number of bulk-fill composites was significant difference was noted between x-
significantly higher than that of conventional tra fil and Tetric N-Ceram in microhardness.
composite (P<0.05). After 40 seconds of curing:
-At 3.5, 4 and 4.5mm depths, the Vickers -At 0.1mm depth, no significant difference
hardness number of x-tra fil was was noted in microhardness between x-tra fil
significantly higher than that of Tetric-N and Tetric N-Ceram (P=0.07) or between
Ceram (P<0.05). Tetric N-Ceram and Grandio (P=0.90).
After 30 seconds of curing: However, x-tra fil had significantly higher
-At 0.1mm depth, a significant difference in microhardness than Grandio (P<0.05).
hardness was detected between x-tra fil and -At 2mm depth, significant differences were
Tetric N-Ceram and also between x-tra fil detected in microhardness between x-tra fil
and Grandio (P<0.05). The hardness was and Tetric N-Ceram and also between x-tra
higher in x-tra fil but no significant fil and Grandio (P<0.05). Vickers hardness
difference was found between Tetric N- number of x-tra fil composite was
Ceram and Grandio (P=0.99). significantly higher than that of other
-At 2 mm depth, a significant difference was composites but the difference between Tetric
found in microhardness among all N-Ceram and Grandio in this regard was not
understudy composites (P<0.05). The significant (P=0.99).
microhardness of x-tra fil was higher than
that of Tetric N-Ceram and the -At 2.5mm depth, microhardness of x-tra fil
microhardness of the latter was higher than was significantly higher than that of Tetric
that of Grandio. N-Ceram and Grandio (P<0.05).
-At 2.5 and 3mm depths, no significant -At 3mm depth, the microhardness of bulk-
difference was noted between bulk-fill fill composites was significantly higher than
Curing Time & Polymerization Rate of Composite Resins 218
color (shade) of restorative materials, light 20 and 30 seconds to 2mm depth but further
curing time, distance form the light source to increasing the polymerization time from 30
the surface of sample, and light intensity to 40 seconds increased the microhardness at
affect the rate and depth of polymerization all depths.
(24). The current study evaluated the effect
of duration of curing on polymerization Increased microhardness due to increased
depth of bulk-fill composites. polymerization time has been reported in
some previous studies (18,19,32). For
Microhardness measurement is a simple instance, Alpoz et al, (19) in 2008 compared
method to evaluate the quality of the microhardness and compressive strength
polymerization of composites (25-27). The of Tetric-Ceram, Compomer, Compoglass
quantity of hardness refers to strength and and Fuji II LC glass ionomer using halogen
resistance against a compressive force (28). and LED light curing units following 20 and
Surface hardness of a composite resin relates 40 seconds of curing and concluded that
to its resistance to deformation and increasing the curing time using LED light
capability to remain stable (29). In the curing unit increased the microhardness of
current study, we used microhardness test to all materials and was suitable for composite
assess the quality of polymerization of resin polymerization in deep cavities. Such
composites using Vickers hardness tester by an increase in microhardness following
applying 300g load for 15 seconds. increased curing time has also been reported
Microhardness in each indentation was by Mousavinasab and Meyers (34) in 2011.
measured. This method has been However, some studies did not find a
successfully used for measurement of correlation between microhardness number
microhardness by many previous studies and longer polymerization time (35-37). For
(30-33). instance, Flury et al, (36) in 2012 measured
the curing depth of bulk-fill composites
Our results showed that increasing the using two methods of ISO4049 and
polymerization time increased the microhardness testing after 10 and 20
microhardness of x-tra fil composite to 2mm seconds of curing and reported no
depth but had no effect on polymerization at significant difference in microhardness of
2-4mm depths. In Tetric N-Ceram, by Tetric N-Ceram cured for 10 and 20
increasing the polymerization time from 20 seconds. In our study, no change in
to 30 seconds, microhardness increased at 2, microhardness of Tetric N-Ceram was
2.5, 3 and 3.5mm depths but further observed by increasing the curing time from
increasing the polymerization time from 30 30 to 40 seconds at 2-3.5 mm depths. This
to 40 seconds did not cause any change in finding (no increase in microhardness) may
microhardness of samples. In this composite, be attributed to the different types of
microhardness at 4mm depth was not initiators, using two initiators and adequate
affected by the polymerization time. In polymerization of Tetric N-Ceram (38).
Grandio composite, no difference in Microhardness measurement at deeper
microhardness was noted between curing for underlying layers may reveal differences in
Curing Time & Polymerization Rate of Composite Resins 220
References:
1. Park SH. Comparison of degree of conversion for light cured and additionally heat cured
composites. J Prosthet Dent. 1996 Dec;76(6):613-8.
Jaberi Ansari, et al. 221
2. Kusy RP. Orthodontic Biomaterials: from the Past to the Present. Angle Orthod. 2002
Dec;72(6):501-12.
3. Geurtsen W, Spahl W, Leyhausen G. Residual monomer/additive release and variability
in cytotoxicity of light curing glass-ionomer cements and compomers. J Dent Res. 1998
Dec;77(12):2012-9.
4. Geurtsen W, Leyhausen G, Garcia-Godoy F. Effect of storage media on the fluride
release and surface microhardness of four palacid modified composite resins
("compomers"). Dent Mater. 1999 May;15(3):196-201.
5. Kwon YH, Kwon TY, Ong JL, Kim KH. Light- polymerized compomers: coefficient of
thermal expantion and microhardness. J Prosthet Dent. 2002 Oct;88(4):396-401.
6. Price RB, Derand T, Lonev RW, Andreou P. Effect of light source and specimen
thickness on the surface hardness of resin composite. Am J Dent. 2002 Feb;15(1):47-53.
7. Leinfelder KF. Posterior composite resins: the materials and their clinical performance. J
Am Dent Assoc. 1995 May;126(5):663-4.
8. Chen HY, Manhart J, Hickel R, Kunzelmann KH. Polymerization contraction stress in
light-cured packable composite resins. Dent Mater. 2001 May;17(3):253-9.
9. Moore BK, Platt JA, Borges G, Chu TM, Katsilieri I. Depth of cure of dental resin
composites: ISO 4049 depth and microhardness of types of materials and shades. Oper
Dent. 2008 Jul-Aug;33(4):408-12.
10. Uctasli S, Shortall AC, Burke FJ. Effect of accelerated restorative techniques on the
microleakage of Class II composites. Am J Dent. 2002 Jun;15(3):153-8.
11. McCabe JF, Carrick TE. Output from visible-light activation units and depth of cure of
light activated composites. J Dent Res. 1989 Nov;68(11):1534-9.
12. Leonard DL, Charlton DG, Roberts HW, Cohen ME. Polymerization efficiency of LED
curing lights. J Esthet Restor Dent. 2002;14(5):286-95.
13. Li J, Li H, Fok AS, Watts DC. Multiple correlations of material parameters of light-cured
dental composites. Dent Mater. 2009 Jul;25(7):829-36.
14. Rode KM, Kawano Y, Turbino ML. Evaluation of curing light distance on resin
composite microhardness and polymerization. Oper Dent. 2007 Nov-Dec;32(6):571-8.
15. Potgieter E, Osman Y, Grobler SR. The effect of three whitening oral rinses on enamel
micro-hardness. SADJ. 2014 May;69(4):152, 154-6.
Curing Time & Polymerization Rate of Composite Resins 222
28. Seares CJ, Pizi ECG, Fonseca RB, Martins LRM. Mechanical properties of light –cured
composires polymerized with several additional post-curing methods. Oper Dent. Oper
Dent. 2005 May-Jun;30(3):389-94.
29. Kanca J. Visible light-activated posterior composite resins-a comparison of surface
hardness and uniformity of cure. Quintessence Int. 1985 May;16(5):345-7.
30. Poggio C, Lombardini M, Gaviati S, Chiesa M. Evaluation of Vickers hardness and depth
of cure of six composite resins photo-activated with different polymerization modes. J
Conserv Dent. 2012 Jul;15(3):237-41.
31. Yaman BC, Efes BG, Dörter C, Gömeç Y, Erdilek D, Büyükgökçesu S. The effects of
halogen and light-emitting diode light curing on the depth of cure and
surfacemicrohardness of composite resins. J Conserv Dent. 2011 Apr;14(2):136-9.
32. Mousavinasab SM, Meyers I.Curing efficacy of light emitting diodes of dental curing
units. J Dent Res Dent Clin Dent Prospects. 2009 Winter;3(1):11-6.
33. Choudhary S, Suprabha B. Effectiveness of light emitting diode and halogen light curing
units for curing microhybrid and nanocomposites. J Conserv Dent. 2013 May;16(3):233-
7.
34. Mousavinasab SM, Meyers I. Comparison of Depth of cure, Hardness and Heat
Generation of LED and High Intensitu QTH Light Sources. Eur J Dent. 2011
Jul;5(3):299-304.
35. Okte Z, Villalta P, Garcia-Godoy F, Garcia-Godoy F Jr, Murray P. Effect of curing time
and light curing systems on the surface hardness of compomers. Oper Dent. 2005 Jul-
Aug;30(4):540-5.
36. Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A. Depth of cure of resin composites: is
the ISO 4049 method suitable for bulk fill materials? Dent Mater2012 May;28(5):521-8.
37. Catelan A, Pollard T, Bedran-Russo A, Santos P dos, Aihorosano G, Aguiar F. Light-
curing time and aging effects on the nanomechanical properties of methacrylate – and
silorane-based restorations. Oper Dent. 2014 Jul-Aug;39(4):389-97.
38. Moszner N, Fischer UK, Ganster B, Liska R, Rheinberger V. Benzoyl germanium
derivatives as novel visible light photoinitiators for dental materials. Dent Mater. 2008
Jul;24(7):901-7.
Curing Time & Polymerization Rate of Composite Resins 224
39. EL-Safty S, Akhtar R,Silikas N, Watts DC. Nanomechanical properties of dental resin
composites. Dent Mater. 2012 Dec;28(12):1292-300.
40. Lee YK, Lu H, Powers JM. Measurement of opalescence of resin composites. Dent
Mater. 2005 Nov;21(11):1068-74.
41. Azzopardi N, Moharamzadeh K, Wood DJ, Martin N, van Noort R. Effect of resin matrix
composition on the translucency of experimental dental composite resins. Dent Mater.
2009 Dec;25(12):1564-8.
42. Emami N, Sjodahl M, Soderholm KJ. How filler properties, filler fraction, sample
thickness and light source affect light attenuation in particulate filled resin composites.
Dent Mater. 2005 Aug;21(8):721-30.
43. Masotti AS, Onofrio AB, Conceicao EN, Spohr AM. UV–vis spectrophotometric direct
transmittance analysis of composite resins. Dent Mater. 2007 Jun;23(6):724-30.