PRODUCT MANUAL

ENGLISH

GE 150
VERSION 1.1/0116
GE 150

Manufacturer's Reference:
This equipment fulfils the requirements of the EU directive 2004/108/EC (EMC).

Therefore this equipment is CE-labelled.


Please keep this description in safe custody!

Caution:
This is a Class A product (standard 55022). In a domestic environment this product may cause radio inter-
ference in which case the user may be required to take adequate measures.

Mounting and installation of the Intercom Server and of the equipment may be carried out by authorised
service personnel only. Cards may be exchanged only while the voltage is switched off.

Always make sure ESD precautions have been taken before exchanging cards. The M3 screw nut
of the motherboard G15-GEM (see page 12) is used as grounding point for Wrist Strap Ground-
ing.

GE 150
Version: 1.1/0116
Number of pages: 28

2 1.1/0116
GE 150

Content
Planning information 4 Configuration CCT 800 14
Range of application 4 Configuration via IP or RS-232 14
Expansion 4 Initialization 16
Extent of supply 4 Standard call numbers 16
Additional components 5

Licensing 17
Technical data 7 Upgrading the GE 150 to a GE 300 17
Intercom Server GE 150 7 General 17
Line lengths subscribers 7 The Licensing Process 19
Licensing in CCT 800 21
Licence Website 25
Installation 8
Licence Activation at the Intercom Station 27
Remove lid 8
Plug-in positions of the cards 8
Connection diagram GE 150 9 Technical Support 28
Mounting, Dimensions 9
Cable run 10
Connection plug-in cards 10
Connection Intercom stations 12
LED-Status indication 12

1.1/0116 3
Planning information GE 150

Planning information
The compact Intercom Server GE 150 combines different functions of modern communication such as
Intercom, information and control in one system.

Range of application
The GE 150 is a cost-effective Intercom Server in a compact format – ideal as a stand-alone solution for
small sized applications, including full support of 20 analogue 4-wire Intercom stations and modules.
In a design that is compact enough for wall mounting, the GE 150 Server offers proven Commend In-
tercom functionality, including integrated door/gate control and alarm functions, call forwarding to a
telephone network by using a telephone interface, etc. Via licences, both the Intercom Server and ex-
pansion cards can easily be upgraded to a fully-featured GE 300 Server which offers additional and
proven Intercom features, like the integration of digital and IP subscribers.

Expansion
Subscribers Outputs Inputs
Basic Expansion: 0 2 2 (digital)
Maximum Expansion: 20 40+2 80+2 (digital)

Extent of supply
Intercom Server GE 150 including short reference
The different types have a different extent of supply:
Type: Power supply:
GE 150 without power supply unit
GE 150EU incl. 24 V DC power supply unit
GE 150CA incl. 24 V DC power supply unit with adapters for AUS, USA, UK

4 1.1/0116
GE 150 Planning information

Additional components
For the start-up of the Intercom system, additionally the following components are required:

Subscriber card G15-GET-4B


DSP subscriber card for connection of up to four 4-wire analogue subscribers with feature level “B”.
Up to five G15-GET-B cards can be used with a GE 150 Intercom Server. Every single card provides an
audio bandwidth of 16 kHz and enables OpenDuplex® conversations in 7 kHz.

Subscriber card G15-GET-4B

Telephone interface card G15-TEL


Multi-functional telephone interface for connecting the Intercom system to an analogue subscriber of
a telephone system or directly to a standard telephone line. Telephone mode for direct dialling of the
desired telephone number from an Intercom station. Auto-dialler mode with automatic dialling of free-
ly programmable dialling sequences initiated by calls or call requests. Freely configurable speech stor-
age for acoustic identification and messages (e.g. waiting information) in dialer mode. DTMF-tele-
phones can operate functions in the Intercom system (e.g. once a call has been received on e.g. a re-
mote telephone, all “after dial” functions are available)

Telephone interface card G15-TEL

Input/Output card G15-8E8A


Plug-in card with eight inputs for floating contacts and eight relay outputs (normally open, normally
closed or switch-over). Detection of 5 operation states with inputs (Idle, Active 1, Active 2, Short, Line
break).

Input/Output card G15-8E8A

1.1/0116 5
Planning information GE 150

Input card G15-16E


Plug-in card with 16 inputs for floating contacts. Detection of five operation states with inputs (Idle, Ac-
tive 1, Active 2, Short, Line break)

Input card G15-16E

Licences

With licences the functionality of the Intercom Server and the plug-in cards can be expanded (see
”Licensing” on page 17).
 These components must be ordered separately according to customer requirements.
 Please make sure all required components are at hand before beginning with assembly.

6 1.1/0116
GE 150 Technical data

Technical data

Intercom Server GE 150


Technical data GE 150
Power supply: 24 V DC +/-5%
Emergency power consumption: 200 mAh (without cards)
Power consumption: 30 W
Distortion: less than 0.9%
Operating temperature range: 0° C to +50 °C (32 °F to 122 °F)
Storage temperature range: –30 °C to +60 °C (–22 °F to 140 °F)
Relative humidity: 20% to 80% not condensing
Dimensions of the housing: 310 x 210 x 85 mm (12.21 x 8.27 x 3.15 inch; W x H x D)
Weight including package: approx. 1650 g (3.64 lbs)
Mounting: wall mounting
Relay outputs: max. switching capacity: 60 W / 62.5 VA,
max. switching current: 2 A
max. switching voltage: 60 VDC / 40 VAC
Music input: max. 800 mVrms at 10 kW, 16 kHz
Digital inputs IN1, IN2: for floating contacts, max. line resistance: 1.5 k

Line lengths subscribers


All data about line lengths (series EE 411 with and without display) correspond to a loudspeaker atten-
uation of approx. 10 dB and a microphone attenuation of approx. 3 dB. 9 dB correspond to approx. 3
volume steps adjusted at an EE 411, 3 dB refer to approx. 1 volume step.

Stations with display (series EE 411):


Maximum cable length at diameter:
0.5 mm 0.6 mm 0.8 mm
Cable type: Reference: Capacity
AWG 24 AWG 22 WG 20
J-Y(ST)Y Installation cable PVC 120 nF / km * 750 m 750 m
36.6 nF / 1000 ft 2461 ft 2461 ft
F-YAY Installation cable PVC 100 nF / km * 900 m 900 m
30.5 nF / 1000 ft 2953 ft 2953 ft
KC 102/104 Installation cable PVC 65 nF / km 1000 m * *
19.8 nF / 1000 ft 3281 ft
F-2YA2Y Buried cable polyethylene 55 nF / km * 1500 m 1500 m
16.8 nF / 1000 ft 4922 ft 4922 ft
J-02YS(St)Y Cat. 5 cable, foamed poly- 45 nF / km 1000 m * *
ethylene 13.7 nF / 1000 ft 3281 ft
*...no data, because this diameter is not available for this cable type.

The maximum line capacity for cables not listed in this table is 90 nF. This capacity refers to: A against
B, C against D, C/D together against A as well as the single lines A, B, C, D against an eventual shield
(ground). This capacity can be measured with a multimeter with open end of the line: A against B, C
against D, C/D together against A, A against shield, B against shield, C against shield and D against
shield. All these capacity values may not be higher than 90 nF.

1.1/0116 7
Installation GE 150

Installation

ATTENTION: Switch off power when exchanging cards


Exchanging the cards may only be carried out while the power is switched off!

Remove housing cover


Push here to remove
the housing cover

GE 150

Attention Achtung: Darf nur durch geschultes Personal geöffnet werden #VVGPVKG/CICNNGGPIGQRGPFYQTFGPFQQTIGMYCNKƂEGGTFRGTUQPGGN
OBSERVE PRECAUTIONS FOR HANDLING #VVGPVKQP/C[QPN[DGQRGPGFD[SWCNKƂGFRGTUQPU Attenzione: Darf nur durch geschultes Personal geöffnet werden
OF ELECTROSTATIC SENSITIVE DEVICES! Attention: Seul ie personnel qualife est autorise a l ouvrir! Atencion: Darf nur durch geschultes Personal geöffnet werden

Remove housing cover of Intercom Server

NOTE: Mounting instructions


The housing may be fixed with screws (below the push button of the housing cover, see arrows in the
illustration). This screws have to be removed before opening, see also page 9.

Plug-in positions of the cards


GE 150
1 2 3 4 5
G15-GET     
G15-8E8A     
G15-TEL     
G15-16E     

8 1.1/0116
GE 150 Installation

Connection diagram GE 150


Slot number
Power
1 2 3 4 5
ON
Status LED M3 OFF
Expansion plug

e.g. G15-GET-4B

e.g. G15-GET-4B

e.g. G15-GET-4B
e.g. G15-8E8A

e.g. G15-TEL
IP
Music / Alarm
input
GE 150
+24V –

MUSIC
IN1
RS232
IN2

Inputs for
ƃQCVKPI
contacts

A A
B B
OUT1 OUT2
C C
D D

OUT1 OUT2
Floating outputs (relays)

Connection diagram GE 150

ATTENTION: Pins remain unused


When using the plug-in card G15-8E8A, four pins of the plug in the GE 150 remain unused.

Mounting, Dimensions
Measuring units in mm (inch), not scale!
306 (12.1)
290 (11.4)
180 (7.1)
206 (8.1)

* *
GE 150

Attention Achtung: Darf nur durch geschultes Personal geöffnet werden #VVGPVKG/CICNNGGPIGQRGPFYQTFGPFQQTIGMYCNKƂEGGTFRGTUQPGGN
OR HANDLING #VVGPVKQP/C[QPN[DGQRGPGFD[SWCNKƂGFRGTUQPU Attenzione: Darf nur durch geschultes Personal geöffnet werden
VE DEVICES! Attention: Seul ie personnel qualife est autorise a l ouvrir! Atencion: Darf nur durch geschultes Personal geöffnet werden

* Protection against contact acc. to IEC/EN 60950-1: For installation in the


operator access area, the housing cover has to be screwed onto the housing.

Dimensions GE 150

1.1/0116 9
Installation GE 150

Cable run
M3

Grounding point
for wrist strap
grounding

GE 150
+24V –

min.
120 mm
(4.7 inch)
Cable
bearer
A
B
C
D

Cable bearer Cable clamp NAK 100


140 cm
4
/
(55.1 inch)

Analogue

RJ11/RJ45-Socket

Cable run GE 150

Connection plug-in cards

4-wire subscriber card G15-GET-4B


Analogue Intercom terminals are connected directly to the subscriber cards.
Status subscriber card

Switch for 0 dBm input:


Subscriber 1 normal
Intercom
Subscriber 1
Subscriber 2
Subscriber 3
Subscriber 4

Subscriber 1 for
feed in of AF

Sub.1 Sub.2 Sub.3 Sub.4


ABCD ABCDA BCD ABCD

blue green
Status LEDs

Connection subscriber card G15-GET-4B

10 1.1/0116
GE 150 Installation

Input/Output card G15-8E8A


Status indication Status LEDs
8E8A card for S1 to S8

S1W

S2W

S3W

S4W

S5W

S6W

S7W

S8W
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8

S1

S2

S3

S4

S5

S6

7S

S8
S1
S2
S3
S4
S5
S6
S7
S8
1
2
3
4
Input 1-8 5
6
7
8

Connection input/output card G15-8E8A

Input card G15-16E


Status indication Status LEDs
input card for IN1- IN8
IN12
IN13

IN15
IN16
IN14
IN10
IN11
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8

IN9

1
2
3
4
5
6
7
8

Connection input card G15-16E

ATTENTION:
No voltage may be connected to the inputs. Only floating contacts like e.g. relay contacts, contactors,
keys or switches may be connected.

Telephone interface card G15-TEL


Telephone line: a b
NC NC NC NC

Status-LEDs:
Run Line

Connection telephone interface card G15-TEL

1.1/0116 11
Installation GE 150

Connection Intercom stations


Plug wiring
(snapping hooks on bottom)
Modular socket 8/8 CABD CABD
(not included in extent

RJ 11

RJ 45
of supply)

Plug RJ 45 8/4
DB AC

8 7 5 4 6 3 2 1 S

Subscriber

RJ 11

RJ 11
Intercom Server BAD C
CABD CABD

Connection intercom stations

LED-Status indication

G15-GEM
 LED is blinking in a one second rhythm: the Intercom Server is working correctly
 LED blinking fast: during initialization
 LED is permanently off: no power or hardware fault
 LED is permanently on: reset or hardware fault
 LED blinking in rhythm “definition error“ ( ):
at least one wrong or missing plug-in card

Subscriber card G15-GET-4B


LED positions see ”Subscriber card G15-GET-4B” on page 5.

Status subscriber card:


 LED is blinking in a one second rhythm: the card is working correctly
 LED is permanently off: no power or hardware fault
 LED is permanently on: waiting for connection to the main processor (during initialization) or reset
 LED is blinking fast: the card is in the wrong slot
 LED blinking in rhythm “definition error“ ( ):
wrong type of subscriber card

Status subscriber:
 LED on: a working Intercom station is connected
 LED off: no Intercom station connected
 LED blinking: line fault
 LED flickers: during data transmission

12 1.1/0116
GE 150 Installation

Input/Output cards
LED positions see ”Input/Output card G15-8E8A” on page 5.

Status input/output card:


 LED is blinking in a one second rhythm: the card is working correctly
 LED is permanently off: no power or hardware fault
 LED is permanently on: waiting for connection to the main processor (during initialization) or reset
 LED blinking fast: card inserted in wrong slot

Status outputs (only G15-8E8A):


 LED on: output closed
 LED off: output open

Status inputs (only G15-16E):


 LED on: input active
 LED off: input inactive

Telephone interface card G15-TEL


LED positions see ”Telephone interface card G15-TEL” on page 5.

Status telephone card (“RUN”):


 LED is blinking in a one second rhythm: the card is working correctly
 LED is permanently off: no power, reset or hardware fault
 LED is permanently on: waiting for connection to the main processor (during initialising)
 LED blinking fast: card inserted in wrong slot

Status line (“LINE”):


 LED is permanently on: onhook
 LED blinking fast: DC on telephone line not available
 LED flickers shortly (once per second) during conversation

1.1/0116 13
Configuration CCT 800 GE 150

Configuration CCT 800

Configuration via IP or RS-232


Configuration of GE 150 Intercom Servers can be carried out via a RS-232 or standard network cable.

NOTE: Further information


For configuration of Intercom features see manual “PRO 800”.

GE 150
LED1

IP Uplink
%QPƂIWTCVKQP
%%6XKC+2

RS232

%QPƂIWTCVKQP
Slot 1

Slot 2

Slot 3

Slot 4

Slot 5
%%6XKC45

G15-GEM

Configuration can be carried out via IP or RS-232

IP (Ethernet)
 Connect the PC for configuration with a network cable directly to the Intercom Server (“Uplink” port
of G15-GEM) or with a switch in the network.
 In a network the Intercom Server and the PC must be in the same subnet.
 The Intercom Server is automatically advised an IP address during initialization
(see ”Configuration of IP network settings” on page 16).

NOTE: Connection PC and Intercom Server


To set up the connection between PC and Intercom Server (menu Intercom Server > Connection
Settings), please see manual “PRO 800”.

14 1.1/0116
GE 150 Configuration CCT 800

RS-232
For configuration via RS-232 a 9-way D-Submin extension cable (1:1, Plug: server-side, socket PC-side)
is required.
This cable is connected to the 9-way D-Submin socket on the motherboard G15-GEM
(see ”Connection diagram GE 150” on page 9).
NC 1 1
TXD 2 2
RXD 3 3
NC 4 4
GND 5 5
NC 6 6
NC 7 7
NC 8 8
NC 9 9
GE 150 (9-way D-Submin plug) (9 way D-Submin jack) PC

NC = not connected
This cable can be purchased at an electric outfitter or ordered under the type “X-KAB-CCT”.

NOTE: Connection PC and Intercom Server


To set up the connection between PC and Intercom Server (menu Intercom Server > Connection
Settings), please see manual “PRO 800”.

1.1/0116 15
Configuration CCT 800 GE 150

Initialization
With an initialization of the Intercom Server, the entire server configuration is reset and an IP address for
the G15-GEM is generated (this is required, if the CCT 800 configuration is carried out via IP (Ethernet)).

1. Menu Intercom Server > Initialize


2. In the field Current Server-ID the current Server-ID is displayed. In the field New Server-ID the desired
number is entered and taken over with initialize.

ATTENTION: Server ID “1”


Always use “1” as Server ID for the GE 150!

Initialisation of new Server-ID

As soon as the number is transmitted it also appears in the field Server-ID.


3. Receive the configuration of the Intercom Server (menu Intercom Server > Receive, in the area
Receive all Intercom Servers must be visible). Now all cards are correctly recognised and the
Intercom Server can be configured as usual.

Configuration of IP network settings


Auto-configurkration of the network
When a GE 150 is initialized, an IP address is automatically generated for the G15-GEM:
G15-GEM
GE 150 – Server-ID No. 1 10.10.1.1

Standard call numbers


Call number
Slot 1 101 - 104
Slot 2 105 - 108
Slot 3 109 - 112
Slot 4 113 - 116
Slot 5 117 - 120

NOTE: Call numbers allocated dynamically


The call numbers are allocated dynamically. If subscriber cards are added / exchanged at a later time,
the next available call number range is allocated!

16 1.1/0116
GE 150 Licensing

Licensing

Upgrading the GE 150 to a GE 300


The GE 150 Intercom Server can be upgraded to an GE 150 Intercom Server by software licences.

NOTE: Further information


For further information about the upgrade (like e.g. required licences, benefits etc.) see datasheet
“GE 150”..

ATTENTION: Upgrading to GE 300


When upgrading the GE 150 Intercom Server to a GE 300 Intercom Server, it is mandatory to also
upgrade every single plug-in card!

In the following sections, the general licensing process (for all available licences) is described.

General
Via licences additional features of the Intercom Server, plug-in cards and external software products
can be activated. These licences are protected against misuse via a hardware assisted system.
With CCT 800 and an active internet connection the licences can be administered with ease. If no inter-
net connection is available the activation can also be carried out at a later moment via a website (see
page 25).
Per ordered licence, one licence sheet is delivered.

COMMEND SOFTWARE LICENSE


Thank you for choosing this quality software product from Commend.
As this software is protected by the latest security measures, you
will need to complete an Activation process before it can be used.
Detailed information can be found in the Intercom Server Installation
Manual supplied with your system. You can direct any queries to
your local Commend Partner whose contact details can be found at
www.commend.com (click on Contact).

L-COMWIN-N.C
Rev.: AA
SN 1057465

C–L–COMWIN–N.C#AA#01647096#

Keep this license information in a safe place! During the Activation


process, you will be prompted for the following license key:

T123 – 456 –123456789 –789


Self-adhesive License
information label.

Adhesive label
Product L-COMWIN-N.C 2D barcode
Rev.: AA
Licence type SN 1057465
For safe keeping, attach
label to the system site
documentation.

RUN
Licence key License Key:
T123 – 456 –123456789 –789

Example licence sheet

 Attach the adhesive label in the system site documentation.


 The licence sheet should be kept in safe custody for service purposes.

1.1/0116 17
Licensing GE 150

Advantages
 From each card type only one version must be ordered on stock
 Only the card with the lowest feature level is available (description of feature level see manual
“PRO 800”)
 This card is then upgraded via the licence
 Activation of the licences via internet with the central licence server
 Manual activation without internet connection is also possible (see page 25)
 Licences can be deactivated and transferred to other Intercom Servers
 Licences can be activated and deactivated up to 15 times (for transfer to other Servers)
 Not allocated licences can be saved in files and licence pools and therefore be exchanged elec-
tronically (e.g. per eMail)
 Easy entering of the licence code in CCT 800 and on the website with 2D barcode scanners
(e.g. Metrologic MS 1690)

Terminology
The following terms are used during the licencing procedure:

Licence key
E.g.: T170-100-142577008-027
(Product-ID-Run-Licence code-Check sum)
 Is printed on licence sheet
 Contains licence code and checksum
 Is not allocated to a specific Intercom Server

Activation code
E.g.: T170-0815-1508-1147-4711-0815
 Is generated as soon as a licence key is allocated to an Intercom Server with serial number
 Is only required when no internet connection is available during CCT-configuration

Deactivation code
E.g.: T170-4711-0815-4711-0815-4711
 Is generated by the Intercom Server (G3-GEM) and is required to deactivate the licence at the licence
server. After deactivation and release at the licence server the licence can be allocated to a different
Intercom Server. This increases the generation number by 1 step.
 Is only required when no internet connection is available during CCT-configuration

Generation
Licences are valid for 15 generations. After that the licence becomes invalid.
The following actions increase the generation number:
 One activation
 Moving of a licence to a different Intercom Server
 The licence is deactivated and re-activated internally
 When a licence is moved within an Intercom Server the generation number is not increased
(see ”Card Area” on page 21)

18 1.1/0116
GE 150 Licensing

The Licensing Process


The following example shows a typical licensing process

Example licensing process

1. Receiving of the serial number of the Intercom Server  Allocation of the licence key to the serial
number of the Intercom Server in CCT 800 (see page 24).
2. CCT 800 sends licence key and serial number to the licence server
3. The licence server calculates the activation code and sends it back to CCT 800
4. CCT 800 sends activation code to Intercom Server  licensing process complete
The licensing process depends on the two following factors:
 CCT 800 has or has no connection to the internet
 CCT 800 has or has no connection to the Intercom Server

1.1/0116 19
Licensing GE 150

Depending on these factors the licensing process follows a different procedure.

connection create offline-CCT-file and


receive configuration Yes CCT to No enter the serial number
of Intercom Server Intercom of the Intercom Servers
Server or open CCT-file

allocate licences

Yes Internet No
connection

licences are
licences are activated/deactivated
activated/deactivated via the website
by CCT automatically and manually
entered in CCT

connection Activation/deactivation
Activation/deactivation Yes No
CCT to of licences in the Intercom
of licences in the
Intercom Server via station with
Intercom Server
Server Dot-Matrix Display
automatically via CCT
(e.g. EE 811)

Licensing process

20 1.1/0116
GE 150 Licensing

Licensing in CCT 800

Configuration CCT 800


 Receive the configuration of the Intercom Server.
 Menu Intercom Server > License administration

1 Licence Pool

2 Server Area 3 Card Area

Licence administration in CCT

Licence Pool
 In the licence pool (1) all available licences are displayed, that have been added to the licence pool
via Enter Licence(s) and Create Temporary License (see page 22).

Server Area
 In the server area (2) all Intercom Servers in the project are listed. Here the desired Server can be
selected, to which the licence shall be allocated.
 If “Project” is selected, the card area displays all Servers in the Project.

Card Area
 The card area (3) shows a detailed view of all the cards and allocated licences of the Intercom Server
selected in the server area (see page 23).
 Get Licence Data: Receives the current licence data from the Intercom Server.
 Synchronize: Synchronizes the licence data with the licence server and the Intercom system.
 Show inactive licenses: If this check-box is activated, the card area also displays inactive and de-
activated licences.
 Test License Server Connection: A successful connection test is indicated with a green tick mark
and a hint “connection via proxy successful”. A failed connection test is indicated with a red cross
and a hint “connection via proxy failed”. The red cross is also shown at incorrect or non-existing
proxy server settings.

1.1/0116 21
Licensing GE 150

Licence Pool
Before a licence can be allocated to an Intercom Server it must be added to the licence pool. For this
there are two possibilities:
 Enter purchased licences (Run / Demo, see “Enter purchased licences”)
 Create temporary licences (see “Create temporary licences”)

Enter purchased licences


 Enter the purchased licences at Enter Licence(s)

Enter license to licence pool

 Licence key: In this field the licence key is entered


 Click Add to add the licence in the field licence code to the licence pool
 Click Remove to remove the selected licence from the licence pool

Licences can also be saved in a licence pool file:


 Click Save to save the licences in the licence pool in a LIC-file
 Click Load to load a previously generated licence pool file

22 1.1/0116
GE 150 Licensing

Create temporary licences


 Create the temporary licences at Create Temporary License

Create temporary licence

 Select the required amount of licences per type in the column Count
 Click Create to add the selected temporary licences to the licence pool

The Card Area

Card area

 Address: In this field certain licences are allocated to specific subscribers or interface ports.
 Licence Product: Displays the name of the licence product
 Licence Type (time left): Displays the licence type and the time left at Temp-licenses
 Licence key: Displays the licence key
 Generation: Displays the generation number (1 – 15)
 State: Displays the state of the licence. The following states are possible:
 Activation pending: Licence is allocated to a card, however is not activated in the Intercom Server
and at the licence server
 Activated: Licence is activated at the licence server, however not in the Intercom Server
 Synchronisation must be carried out – click Synchronize
 Live: Licence is active, features can be used
 Deactivation pending: Licence is prepared for deactivation, however still active in the Intercom
Server and at the licence server
 Deactivated*: Licence is deactivated in the Intercom Server, however not yet at the licence server
 Synchronisation must be carried out – click Synchronize
 Inactive*: Licence is deactivated in the Intercom Server and at the licence server an can now be
activated at a different Intercom Server
* only visible if “Show inactive licenses” is activated (see page 21)

1.1/0116 23
Licensing GE 150

Allocation of Licences
1. Add the acquired licences to the licence pool (see page 22)
2. Select the desired Server in the Intercom Server area (2)
3. Drag-and-Drop the licences onto the desired cards in the card area (3) (see page 22)
4. After allocation of the licences click Synchronize

Deactivation of Licences
 Select the licence to be deactivated in the card area
 Click on the licence with the right mouse button and select Detach / Deactivate
 Acknowledge the Deactivation with YES
 The deactivated licence is moved back to the licence pool
 Click Synchronize
 At inactive internet connection the licence must be deactivated at the licence server via the web-
site (see ”Licence Website” on page 25)

Indication of Licences in the CCT-File


Activated licences are displayed in the CCT-file.

Display of activated licences in CCT

Configuration CCT 800:


 Intercom Server > Subscriber licences
 In this dialogue the activated licences are displayed per:
 Server (G8-GEP, G3-GEM)
 Subscriber card
 Interface card / Interface port
 Network card
 Click on the button Licences to open the licencing dialogue.
 Open the folder Subscriber licences and select a Intercom Server or individual cards to display the
active licences for the selection.

24 1.1/0116
GE 150 Licensing

Licence Website
If no internet connection is available during the licensing process in CCT 800, the licences can be acti-
vated/deactivated via a website.
With the following URLs the licences can be activated or deactivated

Activation
 http://license.intercom-online.cc/Activation.aspx?language=en

Activation via licence website

 Enter the serial number of the GE 800 / GE 150 Intercom Server in the field SN GEP/GEM
 In the field next to it the Licence key is entered, that is allocated to the cards in the Intercom Server
 Click start activation
 An activation code is generated, that must be entered in CCT 800
 In the card area click on the licence with the right mouse button and select Enter/Change activa-
tion code

Enter activation code

 Enter the activation code and accept with OK


 Click Synchronize

Deactivation
 In the card area click on the licence with the right mouse button and select Enter/Change activa-
tion code

Enter deactivation code

1.1/0116 25
Licensing GE 150

 Write down or copy the deactivation code


 http://license.intercom-online.cc/Deactivation.aspx?language=de

Deactivation via website

 Enter the code in the field Deactivation Code


 Click start deactivation
 The licence is deactivated at the licence server and can be allocated to a different Intercom Server

26 1.1/0116
GE 150 Licensing

Licence Activation at the Intercom Station


If no internet connection is available during CCT-configuration the activation codes can also be entered
at an Intercom station with Dot-Matrix Display (e.g. EE 811A).

Entering Activation Codes


 Dial 9T8 at the station
The following menu is displayed:
Licensing
Number _

Server
Slot

Scrolling
X-Cancel
Diial 9T8 at the station

 Press the T button  cursor switches to “Server”


 Enter the Server-ID and press T
 Enter the slot number in the server and press T - The following menu is displayed:
Licensing
Server 1- 1
T114-3464-29
- -

Scrolling
X-Cancel
Enter slotnumber of the server and press T

 Enter the activation code

Licences for subscribers


 Dial 9T8 at the station
 Enter the call number of the subscriber
 Press the T button
 Enter the activation code

1.1/0116 27
Technical Support GE 150