Академический Документы
Профессиональный Документы
Культура Документы
ENGLISH
GE 150
VERSION 1.1/0116
GE 150
Manufacturer's Reference:
This equipment fulfils the requirements of the EU directive 2004/108/EC (EMC).
Caution:
This is a Class A product (standard 55022). In a domestic environment this product may cause radio inter-
ference in which case the user may be required to take adequate measures.
Mounting and installation of the Intercom Server and of the equipment may be carried out by authorised
service personnel only. Cards may be exchanged only while the voltage is switched off.
Always make sure ESD precautions have been taken before exchanging cards. The M3 screw nut
of the motherboard G15-GEM (see page 12) is used as grounding point for Wrist Strap Ground-
ing.
GE 150
Version: 1.1/0116
Number of pages: 28
2 1.1/0116
GE 150
Content
Planning information 4 Configuration CCT 800 14
Range of application 4 Configuration via IP or RS-232 14
Expansion 4 Initialization 16
Extent of supply 4 Standard call numbers 16
Additional components 5
Licensing 17
Technical data 7 Upgrading the GE 150 to a GE 300 17
Intercom Server GE 150 7 General 17
Line lengths subscribers 7 The Licensing Process 19
Licensing in CCT 800 21
Licence Website 25
Installation 8
Licence Activation at the Intercom Station 27
Remove lid 8
Plug-in positions of the cards 8
Connection diagram GE 150 9 Technical Support 28
Mounting, Dimensions 9
Cable run 10
Connection plug-in cards 10
Connection Intercom stations 12
LED-Status indication 12
1.1/0116 3
Planning information GE 150
Planning information
The compact Intercom Server GE 150 combines different functions of modern communication such as
Intercom, information and control in one system.
Range of application
The GE 150 is a cost-effective Intercom Server in a compact format – ideal as a stand-alone solution for
small sized applications, including full support of 20 analogue 4-wire Intercom stations and modules.
In a design that is compact enough for wall mounting, the GE 150 Server offers proven Commend In-
tercom functionality, including integrated door/gate control and alarm functions, call forwarding to a
telephone network by using a telephone interface, etc. Via licences, both the Intercom Server and ex-
pansion cards can easily be upgraded to a fully-featured GE 300 Server which offers additional and
proven Intercom features, like the integration of digital and IP subscribers.
Expansion
Subscribers Outputs Inputs
Basic Expansion: 0 2 2 (digital)
Maximum Expansion: 20 40+2 80+2 (digital)
Extent of supply
Intercom Server GE 150 including short reference
The different types have a different extent of supply:
Type: Power supply:
GE 150 without power supply unit
GE 150EU incl. 24 V DC power supply unit
GE 150CA incl. 24 V DC power supply unit with adapters for AUS, USA, UK
4 1.1/0116
GE 150 Planning information
Additional components
For the start-up of the Intercom system, additionally the following components are required:
1.1/0116 5
Planning information GE 150
Licences
With licences the functionality of the Intercom Server and the plug-in cards can be expanded (see
”Licensing” on page 17).
These components must be ordered separately according to customer requirements.
Please make sure all required components are at hand before beginning with assembly.
6 1.1/0116
GE 150 Technical data
Technical data
The maximum line capacity for cables not listed in this table is 90 nF. This capacity refers to: A against
B, C against D, C/D together against A as well as the single lines A, B, C, D against an eventual shield
(ground). This capacity can be measured with a multimeter with open end of the line: A against B, C
against D, C/D together against A, A against shield, B against shield, C against shield and D against
shield. All these capacity values may not be higher than 90 nF.
1.1/0116 7
Installation GE 150
Installation
GE 150
Attention Achtung: Darf nur durch geschultes Personal geöffnet werden #VVGPVKG/CICNNGGPIGQRGPFYQTFGPFQQTIGMYCNKƂEGGTFRGTUQPGGN
OBSERVE PRECAUTIONS FOR HANDLING #VVGPVKQP/C[QPN[DGQRGPGFD[SWCNKƂGFRGTUQPU Attenzione: Darf nur durch geschultes Personal geöffnet werden
OF ELECTROSTATIC SENSITIVE DEVICES! Attention: Seul ie personnel qualife est autorise a l ouvrir! Atencion: Darf nur durch geschultes Personal geöffnet werden
8 1.1/0116
GE 150 Installation
e.g. G15-GET-4B
e.g. G15-GET-4B
e.g. G15-GET-4B
e.g. G15-8E8A
e.g. G15-TEL
IP
Music / Alarm
input
GE 150
+24V –
MUSIC
IN1
RS232
IN2
Inputs for
ƃQCVKPI
contacts
A A
B B
OUT1 OUT2
C C
D D
OUT1 OUT2
Floating outputs (relays)
Mounting, Dimensions
Measuring units in mm (inch), not scale!
306 (12.1)
290 (11.4)
180 (7.1)
206 (8.1)
* *
GE 150
Attention Achtung: Darf nur durch geschultes Personal geöffnet werden #VVGPVKG/CICNNGGPIGQRGPFYQTFGPFQQTIGMYCNKƂEGGTFRGTUQPGGN
OR HANDLING #VVGPVKQP/C[QPN[DGQRGPGFD[SWCNKƂGFRGTUQPU Attenzione: Darf nur durch geschultes Personal geöffnet werden
VE DEVICES! Attention: Seul ie personnel qualife est autorise a l ouvrir! Atencion: Darf nur durch geschultes Personal geöffnet werden
Dimensions GE 150
1.1/0116 9
Installation GE 150
Cable run
M3
Grounding point
for wrist strap
grounding
GE 150
+24V –
min.
120 mm
(4.7 inch)
Cable
bearer
A
B
C
D
Analogue
RJ11/RJ45-Socket
Subscriber 1 for
feed in of AF
blue green
Status LEDs
10 1.1/0116
GE 150 Installation
S1W
S2W
S3W
S4W
S5W
S6W
S7W
S8W
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
S1
S2
S3
S4
S5
S6
7S
S8
S1
S2
S3
S4
S5
S6
S7
S8
1
2
3
4
Input 1-8 5
6
7
8
IN15
IN16
IN14
IN10
IN11
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
1
2
3
4
5
6
7
8
ATTENTION:
No voltage may be connected to the inputs. Only floating contacts like e.g. relay contacts, contactors,
keys or switches may be connected.
Status-LEDs:
Run Line
1.1/0116 11
Installation GE 150
RJ 11
RJ 45
of supply)
Plug RJ 45 8/4
DB AC
8 7 5 4 6 3 2 1 S
Subscriber
RJ 11
RJ 11
Intercom Server BAD C
CABD CABD
LED-Status indication
G15-GEM
LED is blinking in a one second rhythm: the Intercom Server is working correctly
LED blinking fast: during initialization
LED is permanently off: no power or hardware fault
LED is permanently on: reset or hardware fault
LED blinking in rhythm “definition error“ ( ):
at least one wrong or missing plug-in card
Status subscriber:
LED on: a working Intercom station is connected
LED off: no Intercom station connected
LED blinking: line fault
LED flickers: during data transmission
12 1.1/0116
GE 150 Installation
Input/Output cards
LED positions see ”Input/Output card G15-8E8A” on page 5.
1.1/0116 13
Configuration CCT 800 GE 150
GE 150
LED1
IP Uplink
%QPƂIWTCVKQP
%%6XKC+2
RS232
%QPƂIWTCVKQP
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
%%6XKC45
G15-GEM
IP (Ethernet)
Connect the PC for configuration with a network cable directly to the Intercom Server (“Uplink” port
of G15-GEM) or with a switch in the network.
In a network the Intercom Server and the PC must be in the same subnet.
The Intercom Server is automatically advised an IP address during initialization
(see ”Configuration of IP network settings” on page 16).
14 1.1/0116
GE 150 Configuration CCT 800
RS-232
For configuration via RS-232 a 9-way D-Submin extension cable (1:1, Plug: server-side, socket PC-side)
is required.
This cable is connected to the 9-way D-Submin socket on the motherboard G15-GEM
(see ”Connection diagram GE 150” on page 9).
NC 1 1
TXD 2 2
RXD 3 3
NC 4 4
GND 5 5
NC 6 6
NC 7 7
NC 8 8
NC 9 9
GE 150 (9-way D-Submin plug) (9 way D-Submin jack) PC
NC = not connected
This cable can be purchased at an electric outfitter or ordered under the type “X-KAB-CCT”.
1.1/0116 15
Configuration CCT 800 GE 150
Initialization
With an initialization of the Intercom Server, the entire server configuration is reset and an IP address for
the G15-GEM is generated (this is required, if the CCT 800 configuration is carried out via IP (Ethernet)).
16 1.1/0116
GE 150 Licensing
Licensing
In the following sections, the general licensing process (for all available licences) is described.
General
Via licences additional features of the Intercom Server, plug-in cards and external software products
can be activated. These licences are protected against misuse via a hardware assisted system.
With CCT 800 and an active internet connection the licences can be administered with ease. If no inter-
net connection is available the activation can also be carried out at a later moment via a website (see
page 25).
Per ordered licence, one licence sheet is delivered.
L-COMWIN-N.C
Rev.: AA
SN 1057465
C–L–COMWIN–N.C#AA#01647096#
Adhesive label
Product L-COMWIN-N.C 2D barcode
Rev.: AA
Licence type SN 1057465
For safe keeping, attach
label to the system site
documentation.
RUN
Licence key License Key:
T123 – 456 –123456789 –789
1.1/0116 17
Licensing GE 150
Advantages
From each card type only one version must be ordered on stock
Only the card with the lowest feature level is available (description of feature level see manual
“PRO 800”)
This card is then upgraded via the licence
Activation of the licences via internet with the central licence server
Manual activation without internet connection is also possible (see page 25)
Licences can be deactivated and transferred to other Intercom Servers
Licences can be activated and deactivated up to 15 times (for transfer to other Servers)
Not allocated licences can be saved in files and licence pools and therefore be exchanged elec-
tronically (e.g. per eMail)
Easy entering of the licence code in CCT 800 and on the website with 2D barcode scanners
(e.g. Metrologic MS 1690)
Terminology
The following terms are used during the licencing procedure:
Licence key
E.g.: T170-100-142577008-027
(Product-ID-Run-Licence code-Check sum)
Is printed on licence sheet
Contains licence code and checksum
Is not allocated to a specific Intercom Server
Activation code
E.g.: T170-0815-1508-1147-4711-0815
Is generated as soon as a licence key is allocated to an Intercom Server with serial number
Is only required when no internet connection is available during CCT-configuration
Deactivation code
E.g.: T170-4711-0815-4711-0815-4711
Is generated by the Intercom Server (G3-GEM) and is required to deactivate the licence at the licence
server. After deactivation and release at the licence server the licence can be allocated to a different
Intercom Server. This increases the generation number by 1 step.
Is only required when no internet connection is available during CCT-configuration
Generation
Licences are valid for 15 generations. After that the licence becomes invalid.
The following actions increase the generation number:
One activation
Moving of a licence to a different Intercom Server
The licence is deactivated and re-activated internally
When a licence is moved within an Intercom Server the generation number is not increased
(see ”Card Area” on page 21)
18 1.1/0116
GE 150 Licensing
1. Receiving of the serial number of the Intercom Server Allocation of the licence key to the serial
number of the Intercom Server in CCT 800 (see page 24).
2. CCT 800 sends licence key and serial number to the licence server
3. The licence server calculates the activation code and sends it back to CCT 800
4. CCT 800 sends activation code to Intercom Server licensing process complete
The licensing process depends on the two following factors:
CCT 800 has or has no connection to the internet
CCT 800 has or has no connection to the Intercom Server
1.1/0116 19
Licensing GE 150
allocate licences
Yes Internet No
connection
licences are
licences are activated/deactivated
activated/deactivated via the website
by CCT automatically and manually
entered in CCT
connection Activation/deactivation
Activation/deactivation Yes No
CCT to of licences in the Intercom
of licences in the
Intercom Server via station with
Intercom Server
Server Dot-Matrix Display
automatically via CCT
(e.g. EE 811)
Licensing process
20 1.1/0116
GE 150 Licensing
1 Licence Pool
Licence Pool
In the licence pool (1) all available licences are displayed, that have been added to the licence pool
via Enter Licence(s) and Create Temporary License (see page 22).
Server Area
In the server area (2) all Intercom Servers in the project are listed. Here the desired Server can be
selected, to which the licence shall be allocated.
If “Project” is selected, the card area displays all Servers in the Project.
Card Area
The card area (3) shows a detailed view of all the cards and allocated licences of the Intercom Server
selected in the server area (see page 23).
Get Licence Data: Receives the current licence data from the Intercom Server.
Synchronize: Synchronizes the licence data with the licence server and the Intercom system.
Show inactive licenses: If this check-box is activated, the card area also displays inactive and de-
activated licences.
Test License Server Connection: A successful connection test is indicated with a green tick mark
and a hint “connection via proxy successful”. A failed connection test is indicated with a red cross
and a hint “connection via proxy failed”. The red cross is also shown at incorrect or non-existing
proxy server settings.
1.1/0116 21
Licensing GE 150
Licence Pool
Before a licence can be allocated to an Intercom Server it must be added to the licence pool. For this
there are two possibilities:
Enter purchased licences (Run / Demo, see “Enter purchased licences”)
Create temporary licences (see “Create temporary licences”)
22 1.1/0116
GE 150 Licensing
Select the required amount of licences per type in the column Count
Click Create to add the selected temporary licences to the licence pool
Card area
Address: In this field certain licences are allocated to specific subscribers or interface ports.
Licence Product: Displays the name of the licence product
Licence Type (time left): Displays the licence type and the time left at Temp-licenses
Licence key: Displays the licence key
Generation: Displays the generation number (1 – 15)
State: Displays the state of the licence. The following states are possible:
Activation pending: Licence is allocated to a card, however is not activated in the Intercom Server
and at the licence server
Activated: Licence is activated at the licence server, however not in the Intercom Server
Synchronisation must be carried out – click Synchronize
Live: Licence is active, features can be used
Deactivation pending: Licence is prepared for deactivation, however still active in the Intercom
Server and at the licence server
Deactivated*: Licence is deactivated in the Intercom Server, however not yet at the licence server
Synchronisation must be carried out – click Synchronize
Inactive*: Licence is deactivated in the Intercom Server and at the licence server an can now be
activated at a different Intercom Server
* only visible if “Show inactive licenses” is activated (see page 21)
1.1/0116 23
Licensing GE 150
Allocation of Licences
1. Add the acquired licences to the licence pool (see page 22)
2. Select the desired Server in the Intercom Server area (2)
3. Drag-and-Drop the licences onto the desired cards in the card area (3) (see page 22)
4. After allocation of the licences click Synchronize
Deactivation of Licences
Select the licence to be deactivated in the card area
Click on the licence with the right mouse button and select Detach / Deactivate
Acknowledge the Deactivation with YES
The deactivated licence is moved back to the licence pool
Click Synchronize
At inactive internet connection the licence must be deactivated at the licence server via the web-
site (see ”Licence Website” on page 25)
24 1.1/0116
GE 150 Licensing
Licence Website
If no internet connection is available during the licensing process in CCT 800, the licences can be acti-
vated/deactivated via a website.
With the following URLs the licences can be activated or deactivated
Activation
http://license.intercom-online.cc/Activation.aspx?language=en
Enter the serial number of the GE 800 / GE 150 Intercom Server in the field SN GEP/GEM
In the field next to it the Licence key is entered, that is allocated to the cards in the Intercom Server
Click start activation
An activation code is generated, that must be entered in CCT 800
In the card area click on the licence with the right mouse button and select Enter/Change activa-
tion code
Deactivation
In the card area click on the licence with the right mouse button and select Enter/Change activa-
tion code
1.1/0116 25
Licensing GE 150
26 1.1/0116
GE 150 Licensing
Server
Slot
Scrolling
X-Cancel
Diial 9T8 at the station
Scrolling
X-Cancel
Enter slotnumber of the server and press T
1.1/0116 27
Technical Support GE 150
Technical Support
For more information about our products and services visit:
www.software-manuals.com
28 1.1/0116